At least 523 records · Page 29

Thunderstorm and Fair-weather Quasi-Static Electric Fields Over Land and Ocean

Natural lightning and the associated clouds are known to behave differently over land and ocean, but many questions remain. We expand the related observational datasets by obtaining simultaneous quasi-static electric field observations over coastal land, near-shore water, and deep ocean regions during both fair-weather and thunderstorm periods. Oceanic observations were obtained using two 3-m NOAA buoys that were instrumented with Campbell Scientific electric field mills to measure the quasi-static electric fields. These data were compared to selected electric field records from the existing on-shore electric field mill suite of 31 sensors at Kennedy Space Center (KSC). Lightning occurrence times, locations and peak current estimates for both onshore and ocean were provided by the U.S. National Lightning Detection Network. The buoy instruments were first evaluated on-shore at the Florida coast, and the first system was calibrated for field enhancements and to confirm proper behavior of the system in elevated-field environments. The buoys were then moored 20 mi and 120 mi off the coast of KSC in February (20 mi) and August (120 mi) 2014. Diurnal fair-weather fields at both ocean sites matched will with each other and with those found during the Carnegie cruise, but mean values were 33% smaller, due at least in-part to constraints on the calibration procedure. Diurnal fair-weather fields variations at coastal and inland sites were a poorer match than offshore, likely because the offshore environment is “cleaner” with limited variations in local space charge, lower surface aerosol densities, little surface heating to disturb the surface charge layer during fair weather, and fewer local radioactive sources to modulate the near-surface electrical conductivity. Storm-related static fields were 4-5× larger at both oceanic sites than over land, likely due to decreased screening by near-surface space charge produced by corona current. The time-evolution of the electric field and field changes during storm approach are sufficiently different over land and ocean to warrant further study. This work shows the quality, accuracy, and reliability of these data, and has demonstrated the practicality of off-shore electric field measurements for safety- and launch-related decision making at KSC.

Lightning↗

Design and Performance of the CdZnTe VFG Imaging Calorimeter Prototype for Gamma-ray Astronomy

We present the design and first results of the CdZnTe Imaging calorimeter prototype. The CdZnTe Imaging calorimeter has been designed for use in large astrophysical gamma-ray space instruments, and we report here on a small prototype built to validate the approach. The calorimeter is based on virtual Frisch-grid drift-bar CdZnTe detectors. The design is modular, such that multiple crates of 16 bars, each served by a single ASIC, can be arranged in to different configurations depending on the specific requirements for an instrument. The modules are plugged into the readout motherboard in the designed configuration for a given instrument. The detectors are capable of measuring the interaction point of an incident photon in three dimensions and the energy deposited. In this work, we have designed and built a prototype consisting of 4 by 4 module array and have tested it with various radioactive sources to measure its position and energy resolution. The preliminary results demonstrate ~1% FWHM energy resolution and 1-2 mm position resolution for 662 keV photons (Cs137), subject to the further improvement by applying various corrections. We tested the module with a “conventional” analog ASIC readout as well as a wave-front sampling ASIC to compare the results, which is critical for the optimization of the future instrument.

A. A. Moiseev↗

SOI detector with drift field due to majority carrier flow - an alternative to biasing in depletion

This paper reports on a SOI detector with drift field induced by the flow of majority carriers. It is proposed as an alternative method of detector biasing compared to standard depletion. N-drift rings in n-substrate are used at the front side of the detector to provide charge collecting field in depth as well as to improve the lateral charge collection. The concept was verified on a 2.5 x 2.5 mm{sup 2} large detector array with 20 {micro}m and 40 {micro}m pixel pitch fabricated in August 2009 using the OKI semiconductor process. First results, obtained with a radioactive source to demonstrate spatial resolution and spectroscopic performance of the detector for the two different pixel sizes will be shown and compared to results obtained with a standard depletion scheme. Two different diode designs, one using a standard p-implantation and one surrounded by an additional BPW implant will be compared as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reference material manufacture and certification for the AVNG

Testing and demonstration of any radiation measurement system requires the use of appropriate radioactive sources. The AVNG implementation that we describe is an attribute measurement system built by RFNC - VNIIEF in Sarov, Russia. The AVNG detects neutron and gamma radiation signatures and displays the three unclassified attributes of 'plutonium presence,' 'plutonium mass > 2 kg,' and 'plutonium isotopic ratio ({sup 240}Pu to {sup 239}Pu) < 0.1.' The AVNG was tested using a number of reference material (RM) sources with masses and isotopic ratios above and below these thresholds. The AVNG was demonstrated in June 2009 using several of these sources in addition to detector calibration sources. Since the AVNG was designed to measure multi-kg plutonium sources, the RM was manufactured specifically for use with this system. In addition, the RM was used to test the thresholds in the AVNG, so the size and composition of each RM was certified prior to use. In this presentation, we will describe the various steps in the manufacture and certification of these RM sources.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation portal monitor system and method

A portal monitoring system has a cosmic ray charged particle tracker with a plurality of drift cells. The drift cells, which can be for example aluminum drift tubes, can be arranged at least above and below a volume to be scanned to thereby track incoming and outgoing charged particles, such as cosmic ray muons, whilst also detecting gamma rays. The system can selectively detect devices or materials, such as iron, lead, gold and/or tungsten, occupying the volume from multiple scattering of the charged particles passing through the volume and can also detect any radioactive sources occupying the volume from gamma rays emitted therefrom. If necessary, the drift tubes can be sealed to eliminate the need for a gas handling system. The system can be employed to inspect occupied vehicles at border crossings for nuclear threat objects.

47 OTHER INSTRUMENTATION↗

A Dual-Sided Coded-Aperture Radiation Detection System , Nuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors and Associated Equipment

We report the development of a large-area, mobile, coded-aperture radiation imaging system for localizing compact radioactive sources in three dimensions while rejecting distributed background. The 3D Stand-Off Radiation Detection System (SORDS-3D) has been tested at speeds up to 95 km/h and has detected and located sources in the millicurie range at distances of over 100 m. Radiation data are imaged to a geospatially mapped world grid with a nominal 1.25- to 2.5-m pixel pitch at distances out to 120 m on either side of the platform. Source elevation is also extracted. Imaged radiation alarms are superimposed on a side-facing video log that can be played back for direct localization of sources in buildings in urban environments. The system utilizes a 37-element array of 5 x 5 x 50 cm{sup 3} cesium-iodide (sodium) detectors. Scintillation light is collected by a pair of photomultiplier tubes placed at either end of each detector, with the detectors achieving an energy resolution of 6.15% FWHM (662 keV) and a position resolution along their length of 5 cm FWHM. The imaging system generates a dual-sided two-dimensional image allowing users to efficiently survey a large area. Imaged radiation data and raw spectra are forwarded to the RadioNuclide Analysis Kit (RNAK), developed by our collaborators, for isotope ID. An intuitive real-time display aids users in performing searches. Detector calibration is dynamically maintained by monitoring the potassium-40 peak and digitally adjusting individual detector gains. We have recently realized improvements, both in isotope identification and in distinguishing compact sources from background, through the installation of optimal-filter reconstruction kernels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systems for detecting charged particles in object inspection

Techniques, apparatus and systems for detecting particles such as muons. In one implementation, a monitoring system has a cosmic ray-produced charged particle tracker with a plurality of drift cells. The drift cells, which can be for example aluminum drift tubes, can be arranged at least above and below a volume to be scanned to thereby track incoming and outgoing charged particles, such as cosmic ray-produced muons, while also detecting gamma rays. The system can selectively detect devices or materials, such as iron, lead, gold and/or tungsten, occupying the volume from multiple scattering of the charged particles passing through the volume and can also detect any radioactive sources occupying the volume from gamma rays emitted therefrom. If necessary, the drift tubes can be sealed to eliminate the need for a gas handling system. The system can be employed to inspect occupied vehicles at border crossings for nuclear threat objects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results from the DOE Advanced Gas Reactor Fuel Development and Qualification Program

Modular HTGR designs were developed to provide natural safety, which prevents core damage under all design basis accidents and presently envisioned severe accidents. The principle that guides their design concepts is to passively maintain core temperatures below fission product release thresholds under all accident scenarios. This level of fuel performance and fission product retention reduces the radioactive source term by many orders of magnitude and allows potential elimination of the need for evacuation and sheltering beyond a small exclusion area. This level, however, is predicated on exceptionally high fuel fabrication quality and performance under normal operation and accident conditions. Germany produced and demonstrated high quality fuel for their pebble bed HTGRs in the 1980s, but no U.S. manufactured fuel had exhibited equivalent performance prior to the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. The design goal of the modular HTGRs is to allow elimination of an exclusion zone and an emergency planning zone outside the plant boundary fence, typically interpreted as being about 400 meters from the reactor. To achieve this, the reactor design concepts require a level of fuel integrity that is better than that claimed for all prior US manufactured TRISO fuel, by a few orders of magnitude. The improved performance level is about a factor of three better than qualified for German TRISO fuel in the 1980’s. At the start of the AGR program, without a reactor design concept selected, the AGR fuel program selected to qualify fuel to an operating envelope that would bound both pebble bed and prismatic options. This resulted in needing a fuel form that could survive at peak fuel temperatures of 1250°C on a time-averaged basis and high burnups in the range of 150 to 200 GWd/MTHM (metric tons of heavy metal) or 16.4 to 21.8% fissions per initial metal atom (FIMA). Although Germany has demonstrated excellent performance of TRISO-coated UO2 particle fuel up to about 10% FIMA and 1150°C, UO2 fuel is known to have limitations because of CO formation and kernel migration at the high burnups, power densities, temperatures, and temperature gradients that may be encountered in the prismatic modular HTGRs. With uranium oxycarbide (UCO) fuel, the kernel composition is engineered to prevent CO formation and kernel migration, which are key threats to fuel integrity at higher burnups, temperatures, and temperature gradients. Furthermore, the recent poor fuel performance of UO2 TRISO fuel pebbles measured in Chinese irradiation testing in Russia and in German pebbles irradiated at 1250°C, and historic data on poorer fuel performance in safety testing of German pebbles that experienced burnups in excess of 10% FIMA [1] have each raised concern about the use of UO2 TRISO above 10% FIMA and 1150°C and the degree of margin available in the fuel system. This continues to be an active area of study internationally.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reference material manufacture and certification for the AVNG

Testing and demonstration of any radiation measurement system requires the use of appropriate radioactive sources. An attribute measurement system (A VNG) was developed and fabricated at the Russian Federal Nuclear Center, VNIIEF, Russia, under contract with LANL, USA. The A VNG detects neutron and gamma radiation signatures and compares the data analysis results with the specified threshold values for three unclassified attributes; plutonium is present or absent, plutonium mass is greater than or less than the specified threshold value and plutonium isotopic ratio 240 Pu to 239 Pu) is greater than or less then the threshold value. A set of reference materials (RMs) was specially manufactured for the A VNG with masses and isotopic ratios above and below the selected thresholds. The set of RMs was certified in compliance with the Russian metrological requirements. The RMs were used to debug and test the A VNG and to demonstrate the A VNG operation to an American delegation in June 2009. In this presentation, we will describe the various steps in the manufacture and certification of these RM sources.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

First results with a microcavity plasma panel detector

A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1 x 1 x 2 mm cells. It has shown very clean signals of 0.6-2.5 V amplitude, fast rise time of approximately 2 ns and FWHM of about 2 ns with very uniform signal shapes across all pixels. From initial measurements with beta particles from a radioactive source, a maximum pixel efficiency greater than 95% is calculated, for operation of the detector over a 100 V wide span of high voltages (HV). Over this same HV range, the background rate per pixel was measured to be 3-4 orders of magnitude lower than the rate with which the cell was illuminated by the beta source. Pixel-to-pixel count rate uniformity is within 3% and stable within 3% for many days. The time resolution is 2.4 ns, and a very low cell-to-cell crosstalk has been measured between cells separated by 2 mm. (C) 2014 Elsevier B.V. All rights reserved.

Ball, Robert↗

Scalability, Scintillation Readout and Charge Drift in a Kilogram Scale Solid Xenon Particle Detector

We report a demonstration of the scalability of optically transparent xenon in the solid phase for use as a particle detector above a kilogram scale. We employ a liquid nitrogen cooled cryostat combined with a xenon purification and chiller system to measure the scintillation light output and electron drift speed from both the solid and liquid phases of xenon. Scintillation light output from sealed radioactive sources is measured by a set of high quantum efficiency photomultiplier tubes suitable for cryogenic applications. We observed a reduced amount of photons in solid phase compared to that in liquid phase. We used a conventional time projection chamber system to measure the electron drift time in a kilogram of solid xenon and observed faster electron drift speed in the solid phase xenon compared to that in the liquid phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IAEA Guidance on Managing the Interface between Safety and Security for Normal Commercial Shipments of Radioactive Material

Regulations governing the safe transport of radioactive material have been developed and maintained at the international and national levels for more than six decades. Following the events of 9/11, a similar effort was initiated for security during the transport of radioactive material; however, safety and security provisions have generally been developed independent of each other. The responsibility for nuclear security within a State rests entirely with the State but as part of an international effort to address the provisions that complement or conflict with each other in the interface between safety and security during transport, the International Atomic Energy Agency (IAEA) convened a series of consultancy meetings beginning in October 2016, to (a) identify the needs and develop a plan to address those needs for the transport of low-activity radioactive material (defined for the purposes of this effort as “Normal Commercial Shipments”) with respect to the interface between transport safety and transport security, (b) develop guidance on the interface between transport safety and transport security, and (c) development of a model workshop that will inform IAEA Member States of the interface between transport safety and security. Specifically, the materials addressed in the IAEA Technical Report Series, TRS No. 1001 (in preparation), are those that are limited to low activity radioactive material (including nuclear materials) with activities below 3000 A2 – as defined in the IAEA transport safety regulations – or activities below 10 D – as defined in the Code of Conduct on the Safety and Security of Radioactive Sources – depending on the radionuclide(s) involved. Emphasis was placed in the Technical Report on these materials since, worldwide, little effort has focused on security for their transport and such guidance could prove beneficial to regulators and operators in many developing countries. An IAEA Technical Report has been drafted and is currently undergoing final steps for publication. The Technical Report will address the issues identified during the consultancy meetings, with a focus on the needs and methods for clarifying safety–security interfaces. This paper will introduce the structure and contents of the Technical Report and provide an update on its progress toward publication. A separate PATRAM 2019 paper will outline the workshop materials developed to date.

Ladsous, David↗

DETECTION OF NUCLEAR OR OTHER RADIOLOGICAL MATERIALS OUT OF REGULATORY CONTROL AS CRIMINAL/UNAUTHORIZED THREATS TO MAJOR PUBLIC EVENTS

Major Public Events (MPEs), by their nature, draw great public interest and receive intense media attention. They can be anything from sporting events (e.g., Olympics, World Cups) to political summits to large festivals. The threat of nuclear or other radiological materials out of regulatory control during these events is of particular concern. A terrorist could use this material as a dirty bomb to disperse radioactive material in a stadium, or hide dangerous radioactive sources in a garbage can to expose people to harmful radiation, leading to fear and uncertainty. The requirements for nuclear security, preparedness, and operational capabilities for nuclear/radiological detection at MPEs have steadily increased in recent years. Many countries have gained considerable experience in recent years in nuclear security operations at MPEs when hosting these events. Dozens of MPEs hosted around the world each year now provide some level of nuclear security as part of their overall security plan. Several training workshops and courses, co-sponsored by the U.S. Department of Energy / National Nuclear Security Administration and the International Atomic Energy Agency, and conducted through bilateral agreements, are offered each year. These workshops and courses provide the opportunity to share best practices and lessons learned and aid countries to build capacity for nuclear security at their MPEs. Additionally, the International Atomic Energy Agency provides guidance for the detection of radiological threat materials out of regulatory control through the Nuclear Security Systems and Measures for Major Public Events, IAEA Nuclear Security Series No. 18.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of radiation hardness of semiconductor materials against alpha particles for an API detector

An Associated Particle Imaging (API) system consists of a high vacuum chamber where deuterium ions are accelerated on a tritium-loaded target, resulting in alpha particles and neutrons emitted back-to-back, the latter escaping the chamber and used, for example, for tomography of a high-Z sample. An accurate determination of the alpha position is crucial to determine the trajectory of the neutron. Existing API systems have several limitations which a semiconductor-based API detector placed inside the vacuum chamber should not present. The semiconductor material can be either silicon or diamond. In particular, large and fast signals are generated by the alpha interactions in these materials. A pixelated API detector will measure the time and hit position of the alphas produced in the reaction. However, during the lifetime of the generator, the semiconductor detector will be exposed to an intense flux of alpha particles that will degrade its performance over time. To assess the radiation hardness of silicon and diamond against the alpha particles, we exposed single diodes made of either of the two materials to a 5 MeV alpha flux generated by an 241Am radioactive source. During irradiation, the diodes were biased and mounted on current-sensitive preamplifier boards. We have therefore been able to measure insitu the evolution of the waveforms as the damage was accumulating in their substrates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimation of position resolution for DOI-PET detector using diameter 0.2 mm WLS fibers

We have been developing sub mm resolution and $ 1 million DOI-PET detector using wavelength shifting fibers (WLSF), scintillation crystals of plate shape and SiPM (MPPC: HAMAMATSU K. K.). Conventional design of DOI-PET detector is obtained about mm{sup 3} of resolution by using some blocks detecting gamma-ray in mm 3 voxel. It requires the production cost of $ a few ten million or more for high technique of processing crystal and a lot of number of photo-devices, and this technology is reaching the limit of the resolution. Both higher resolution and lower cost of DOI-PET detector production is challenging for PET diagnosis population. We propose two type of detector. One is a whole body PET system, and the other for brain or small animal. Both PET system consist 6 blocks. the former consist of 6 layers 300 mm x 300 mm x 4 mm crystal plate. The latter consist 16 crystal layers, 4 x 4 crystal array. The size of crystal plate is 40 mm x 40 mm x 1 mm.The WLSF sheets connect to upper and lower plane. The whole PET systems connect 8 SiPMs are bonded on each side. For the brain PET, 9 WLSF fibers are bond on the each side. The expected position resolution maybe less than 1 mm at the former. We have estimation experimental performance the system using {sup 22}Na radioactive source. The collection efficiency of WLSF (R-3) sheet was achieved 10% with GAGG at 511 keV. The relation between reconstruction position and incident position is obtained linearity and achieved the resolution of 0.7 mm FWHM for x-axis of DOI by readout WLSF. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PRD3000: A novel Personnel Radiation Detector with Radiation Exposure Monitoring

PRD3000{sup TM} is a novel Personal Radiation Detector (PRD) with personnel radiation dose exposure monitoring. It is intended for First Responders, Law Enforcement, Customs Inspectors protecting critical infrastructures for detecting unexpected radioactive sources, who also need real time Hp(10) dose equivalent information. Traditional PRD devices use scintillator materials instrumented through either a photomultiplier tube or a photodiode photodetector. While the former is bulky and sensitive to magnetic fields, the latter has to compromise radiation sensitivity and energy threshold given its current noise per unit of photo-detection surface. Recently, solid state photodetectors (SiPM), based on arrays of Geiger operated diodes, have emerged as a scalable digital photodetector for photon counting. Their strong breakdown voltage temperature dependence (on the order of tens of milli-volts per K) has however limited their use for portable instruments where strong temperature gradients can be experienced, and limited power is available to temperature stabilize. The PRD3000 is based on the industry standard DMC3000 active dosimeter that complies with IEC 61526 Ed. 3 and ANSI 42.20 for direct reading personal dose equivalent meters and active personnel radiation monitors. An extension module is based on a CsI(Tl) scintillator readout by a temperature compensated SiPM. Preliminary nuclear tests combined with a measured continuous operation in excess of 240 hours from a single AAA battery cell indicate that the PRD3000 complies with the IEC 62401 Ed.2 and ANSI 42.32 without sacrificing battery life time. We present a summary of the device test results, starting with performance stability over a temperature range of - 20 deg. C to 50 deg. C, false alarm rates and dynamic response time. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a measurement system for Uranium electrodeposition control to radiopharmaceuticals production

For 2016, studies by international bodies forecast a crisis in the supply of Molybdenum ({sup 99}Mo), which is the generator of {sup 99m}Tc, widely used for medical diagnoses and treatments. As a result, many countries are making efforts to prevent this crisis. Brazil is developing the Brazilian Multipurpose Reactor (RMB) project, under the responsibility of the National Nuclear Energy Commission (CNEN). The RMB is a nuclear reactor for research and production of radioisotopes used in the production of radiopharmaceuticals and radioactive sources, broadly used in industrial and research areas in Brazil. Electrodeposition of uranium is a common practice to create samples for alpha spectrometry and this methodology may be an alternative way to produce targets of low enriched uranium (LEU) to fabricate radiopharmaceuticals, as {sup 99}Mo, used for cancer diagnosis. To study the electrodeposition, a solution of 10 mM uranyl nitrate, in 2-propanol, containing uranium enriched to 2.4% in {sup 235}U, with pH = 1, was prepared and measurements with an alpha spectrometer were performed. These studies are justified by the need to produce {sup 99}Mo since, despite using molybdenum in bulk, Brazil is totally dependent on its import. In this project, we intend to obtain a process that may be technologically feasible to control the radiation targets for {sup 99}Mo production. (authors)

07 ISOTOPE AND RADIATION SOURCES↗