Ultrasonic Testing (UT) Reference Standard for Additive Manufacturing Quality Control

Many additive manufacturing (AM) reference standards for build quality verification concentrate primarily on external features. In contrast, EPRI proposes a pair of AM reference blocks that feature only internal and embedded forms. This report presents, collates, and discusses quantitative nondestructive evaluation (NDE) results from various techniques, including visual testing (VT), radiographic testing (RT), conventional ultrasonic testing (UT), and full matrix capture/total focusing method (FMC/TFM) scanning. The blocks are intended, as part of a larger series of blocks, to evaluate build quality and the relative performance of different NDE techniques in detecting various features. The limits of detectability and the closeness of the as-built shape to the intended form for certain features are quantified, facilitating direct comparison. Upon analysis of the results of this testing, it was found that FMC/TFM was consistently superior in detection, followed by conventional UT, then VT, and lastly RT.

36 MATERIALS SCIENCE↗

Manufacture of particulate reference materials

Methods for forming particulates that are highly consistent with regard to shape, size, and content are described. Particulates are suitable for use as reference materials. Methods can incorporate actinides and/or lanthanides, e.g., uranium, and can be used for forming certified reference materials for use in the nuclear industry. Methods include formation of an aerosol from an oxalate salt solution, in-line diagnostics, and collection of particles of the aerosol either in a liquid impinger or on a solid surface.

Wellons, Matthew S.↗

Enraf reference level updates for high-level nuclear waste tanks at Hanford site - 15705

The United States Department of Energy Hanford Site Tank Farm has implemented a system for monitoring tank waste levels in all single-shell tanks (SST), double-shell tanks (DST) and miscellaneous catch tanks using Enraf Series 854 level gauges. To ensure an accurate computation of the tank waste levels, a precise calculation of the tank reference level must be kept up to date. A system was developed where accurate waste tank reference levels are kept consistent with each Enraf assembly in the Tank Farms to ensure the continuation of accurate waste level monitoring. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

230Th-234U Model-Ages of Some Uranium Standard Reference Materials

The 'age' of a sample of uranium is an important aspect of a nuclear forensic investigation and of the attribution of the material to its source. To the extent that the sample obeys the standard rules of radiochronometry, then the production ages of even very recent material can be determined using the {sup 230}Th-{sup 234}U chronometer. These standard rules may be summarized as (a) the daughter/parent ratio at time=zero must be known, and (b) there has been no daughter/parent fractionation since production. For most samples of uranium, the 'ages' determined using this chronometer are semantically 'model-ages' because (a) some assumption of the initial {sup 230}Th content in the sample is required and (b) closed-system behavior is assumed. The uranium standard reference materials originally prepared and distributed by the former US National Bureau of Standards and now distributed by New Brunswick Laboratory as certified reference materials (NBS SRM = NBL CRM) are good candidates for samples where both rules are met. The U isotopic standards have known purification and production dates, and closed-system behavior in the solid form (U{sub 3}O{sub 8}) may be assumed with confidence. We present here {sup 230}Th-{sup 234}U model-ages for several of these standards, determined by isotope dilution mass spectrometry using a multicollector ICP-MS, and compare these ages with their known production history.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

New SCALE Sensitivity/Uncertainty Capabilities Applied to Bias Estimation and to Design of MIRTE Reference Experiments

New TSUNAMI tools of SCALE 6, TSURFER and TSAR, are demonstrated to examine the bias effects of small-worth test materials, relative to reference experiments. TSURFER is a data adjustment bias and bias uncertainty assessment tool, and TSAR computes the sensitivity of the change in reactivity between two systems to the cross-section data common to their calculation. With TSURFER, it is possible to examine biases and bias uncertainties in fine detail. For replacement experiments, the application of TSAR to TSUNAMI-3D sensitivity data for pairs of experiments allows the isolation of sources of bias that could otherwise be obscured by materials with more worth in an individual experiment. The application of TSUNAMI techniques in the design of nine reference experiments for the MIRTE program will allow application of these advanced techniques to data acquired in the experimental series. The validation of all materials in a complex criticality safety application likely requires consolidating information from many different critical experiments. For certain materials, such as structural materials or fission products, only a limited number of critical experiments are available, and the fuel and moderator compositions of the experiments may differ significantly from those of the application. In these cases, it is desirable to extract the computational bias of a specific material from an integral keff measurement and use that information to quantify the bias due to the use of the same material in the application system. Traditional parametric and nonparametric methods are likely to prove poorly suited for such a consolidation of specific data components from a diverse set of experiments. An alternative choice for consolidating specific data from numerous sources is a data adjustment tool, like the ORNL tool TSURFER (Tool for Sensitivity/Uncertainty analysis of Response Functionals using Experimental Results) from SCALE 6.1 However, even with TSURFER, it may be difficult to examine a single experiment and differentiate bias due to a test material from bias due to other materials such as fuel and moderator. An alternative method is to perform two experiments on the same critical assembly, one with and one without the test material, and examine differences in the biases due to the introduction of the test material. Techniques to extract a computational bias from pairs of replacement experiments and project that bias, with an associated bias uncertainty, to an application system are described herein.

36 MATERIALS SCIENCE↗

ESTIMATION UNCERTAINTY IN THE DETERMINATION OF THE MASTER CURVE REFERENCE TEMPERATURE

The Master Curve Reference Temperature, T0, characterizes the fracture performance of structural steels in the ductile-to-brittle transition region. For a given material, this reference temperature is estimated via fracture toughness testing. A methodology is presented to compute the standard error of an estimated T0 value from a finite sample of toughness data, in a unified manner for both single temperature and multiple temperature test methods. Using the asymptotic properties of maximum likelihood estimators, closed-form expressions for the standard error of the estimate of T0 are presented for both test methods. This methodology includes statistically rigorous treatment of censored data, which represents an advance over the current ASTM E1921 methodology. Through Monte Carlo simulations of realistic single temperature and multiple temperature test plans, the recommended likelihood-based procedure is shown to provide better statistical performance than the methods in the ASTM E1921 standard.

36 MATERIALS SCIENCE↗

Feasibility studies to establish at the Kazakhstan Ulba metallurgical plant the manufacturing capability to produce low-enriched uranium certified reference materials

One of the salient features of the transition plan that the United States Department of Energy/National Nuclear Security Administration (DOE/NNSA) is presently implementing in the Former Soviet Union countries is the availability of uranium certified reference materials for calibration of nondestructive assay (NDA) measurement equipment. To address this challenge, DOE/NNSA and U.S. national laboratories have focused their cooperative efforts on establishing a reliable source for manufacturing, certifying, and supplying of such standards. The Ulba Metallurgical Plant (UMP), Kazakhstan, which processes large quantities of low-enriched uranium to produce ceramic fuel pellets for nuclear-powered reactors, is well situated to become a key supplier of low-enriched uranium certified reference materials for the country and Central Asia region. We have recently completed Phase I of a feasibility study to establish at UMP capabilities of manufacturing these standards. In this paper we will discuss details of a proposed methodology for uranium down-blending, material selection and characterization, and a proposed methodology of measurement by destructive (DA) and non-destructive (NDA) analysis to form a database for material certification by the competent State authorities in the Republic of Kazakhstan. In addition, we will discuss the prospect for manufacturing of such standards at UMP.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reference Architecture Discussion [Slides]

NREL is developing reference architectures - industry-validated and verified models - to provide a common operational view and emulation environment for analyzing risk to the energy sector. In this presentation, we overview our work in developing these architectures.

97 MATHEMATICS AND COMPUTING↗

Retrospective Analysis of NIST Standard Reference Material 1450, Fibrous Glass Board, for Thermal Insulation Measurements

Thermal conductivity data acquired previously for the establishment of Standard Reference Material (SRM) 1450, Fibrous Glass Board, as well as subsequent renewals 1450a, 1450b, 1450c, and 1450d, are re-analyzed collectively and as individual data sets. Additional data sets for proto-1450 material lots are also included in the analysis. The data cover 36 years of activity by the National Institute of Standards and Technology (NIST) in developing and providing thermal insulation SRMs, specifically high-density molded fibrous-glass board, to the public. Collectively, the data sets cover two nominal thicknesses of 13 mm and 25 mm, bulk densities from 60 kg∙m -3 to 180 kg∙m -3 , and mean temperatures from 100 K to 340 K. The analysis repetitively fits six models to the individual data sets. The most general form of the nested set of multilinear models used is given in the following equation: λ(ρ, T) = α 0 + α 1 ρ +α 2 T + α 3 T 3 +α 4 e - ($\frac{T-a_{5}}{a_{6}}$) 2 = where λ(ρ,T) is the predicted thermal conductivity (W∙m -1 ∙K -1 ), ρ is the bulk density (kg∙m -3 ), T is the mean temperature (K) and $a_i$ (for i = 1, 2, … 6) are the regression coefficients. The least squares fit results for each model across all data sets are analyzed using both graphical and analytic techniques. The prevailing generic model for the majority of data sets is the bilinear model in ρ and T. λ(ρ, T) = α 0 + α 1 ρ +α 2 T One data set supports the inclusion of a cubic temperature term and two data sets with low-temperature data support the inclusion of an exponential term in T to improve the model predictions. Physical interpretations of the model function terms are described. Recommendations for future renewals of SRM 1450 are provided. An Addendum provides historical background on the origin of this SRM and the influence of the SRM on external measurement programs.

regression analysis↗

Isotopic exchange on solid-phase micro extraction fiber in sediment under stagnant conditions: Implications for field application of performance reference compound calibration

An overlooked issue for field application of in situ performance reference compound (PRC) calibration methods is the validity of the assumption that both the sorption of a target compound and desorption of its corresponding PRC follow the first-order kinetics with the same rate constants under stagnant conditions. In the present study, disposable polydimethylsiloxane fibers of 2 sizes (7 and 35 µm) impregnated with 8 13 C-labeled or deuterated PRCs were statically deployed into different marine sediments, from which the kinetics for sorption of the target compounds and desorption of the PRCs were characterized. Nonsymmetrical profiles were observed for exchange of the target analytes and their corresponding PRCs in sediment under stagnant conditions. Further, the hysteretic desorption of PRCs in the kinetic regime may be ascribed to the low chemical potential between the fiber and sediment porewater, which reflects the inability of water molecules to rapidly diffuse through sediment to solvate the PRCs in the aqueous layer around the fiber surface. A moderate correlation (r = 0.77 and r = 0.57, p < 0.05 for both regressions) between the PRC-calibrated equilibrium concentrations of 1,1-dichloro-2,2-bis-(chlorophenyl) ethylene (p,p'-DDE) and polychlorinated biphenyl (PCB)-153 and the lipid normalized levels in worms (Neanthes arenaceodentata) was obtained in co-exposure tests under simulating field conditions, probably resulting from slightly overestimated bioavailability because of the hysteretic desorption of PRCs and toxic effects. Environ Toxicol Chem 2016;35:1978–1985. © 2015 SETAC

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Volumetric Density-Equalizing Reference Map with Applications

The density-equalizing map, a technique developed for cartogram creation, has been widely applied to data visualization but only for 2D applications. Here, we propose a novel method called the volumetric density-equalizing reference map (VDERM) for computing density-equalizing map for volumetric domains. Given a prescribed density distribution in a volumetric domain in $\mathbb{R}^3$, the proposed method continuously deforms the domain, with different volume elements enlarged or shrunk according to the density distribution. With the aid of the proposed method, medical and sociological data can be visualized via deformations of 3D objects. The method can also be applied to adaptive remeshing and shape modeling. Furthermore, by exploiting the time-dependent nature of the proposed method, applications to shape morphing can be easily achieved. Experimental results are presented to demonstrate the effectiveness of the proposed method.

97 MATHEMATICS AND COMPUTING↗

Block Design with Common Reference Samples Enables Robust Large-Scale Label-Free Quantitative Proteome Profiling

Label-free quantitative proteomics has become an increasingly popular tool for profiling global protein abundances. However, one major weakness is the potential performance drift of the LC-MS platform over time, which in turn limits its utility for analyzing large-scale sample sets. To address this, in this work we introduce an experimental and data analysis scheme based on a block-design with common controls within each block for enabling LC-MS-based large-scale label-free quantification. In this scheme, a large number of samples (e.g., >100 samples) are analyzed in smaller, and more manageable blocks, minimizing instrument drift and variability within a block. Furthermore, each designated block also contains common controls (or reference) samples for normalization within and across blocks. We demonstrated the effectiveness of this method by profiling the proteome response of human macrophage THP-1 cells to 11 engineered nanomaterials (ENMs) at two different doses. A total of 116 samples were analyzed in six blocks, yielding an average coverage of 4500 proteins per sample. The data revealed consistent quantification of proteins across all six blocks, as shown by highly stable quantification of house-keeping proteins in all samples and high levels of quantification correlation among samples from different blocks. The data also demonstrated that label-free quantification is robust and accurate enough to quantify even very subtle abundance changes as well as large fold-changes without potential ratio compression as often encountered with isobaric labeling. Our streamlined workflow is easy to implement and can be readily adapted to other large cohort studies for reproducible label-free proteome quantification.

59 BASIC BIOLOGICAL SCIENCES↗

Cited Reference Analysis in a National Laboratory to Assess Journal Usage

Librarians at a large, federally funded, multidisciplinary research organization sought to assess the value provided by the library’s collections. One method for capturing this value includes determining how well their library’s collections meet researcher needs, as expressed by the materials those researchers choose to cite in the production of new scholarly communications. A cited reference analysis was performed on the publications originating from the institution to provide the necessary data for the assessment, as well as to aid in the creation of a core list of journals which will inform future collection development efforts. Overall, this paper fills a gap in the library and information science literature by addressing the citation behaviors of researchers at a large multidisciplinary government research facility, a setting that has not been examined previously.

99 GENERAL AND MISCELLANEOUS↗

Uncertainty evaluation in reference material characterization by double isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS)

Double isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) is one of the most important measurement methods in the establishment of measurement standards for inorganic analysis. However, there is still no good consensus on approaches for uncertainty evaluation in double ID-ICP-MS. Particularly, approaches to treating the instrumental isotopic fractionation (IIF) phenomenon and correlation between uncertainty sources are diverse and often unclear in the literature. Here, an approach for uncertainty evaluation in double ID-ICP-MS measurements is described. Using three certified reference materials (CRMs), it is shown that the IIF effects cancel out and should not be included in the uncertainty budget. Further, a consistent way of considering correlated sources of uncertainty to prevent double counting of uncertainties is described in detail along with an example of measuring the mass fraction of magnesium in an oyster powder CRM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of loads from HAWC2 and OpenFAST for the IEA Wind 15 MW Reference Wind Turbine

Reference wind turbines (RWTs) that reflect the state-of-the-art of current wind energy technology are necessary in order to properly evaluate innovative methods in wind turbine design and evaluation. The International Energy Agency (IEA) Wind Technology Collaboration Platform (TCP) Task 37 has recently developed a new RWT geared towards offshore floating-foundation applications: the IEA Wind 15 MW. The model has been implemented in two aeroelastic codes, OpenFAST and HAWC2, based on an underlying common ontology. However, these toolchains result in slightly different structural parameters, and the two codes utilise different structural models. Thus, to increase the utility of the model, it is necessary to compare the aeroelastic responses. This paper compares aeroelastic loads calculated using different fidelities of the blade model in OpenFAST (ElastoDyn and BeamDyn) and HAWC2 (prismatic Timoshenko without torsion and Timoshenko with fully populated stiffness matrix), where both codes use the DTU Basic controller and the same turbulence boxes to reduce discrepancies. The aeroelastic responses to steady wind, step wind and turbulent wind (per IEC 61400-1 wind class IB) are considered. The results indicate a generally good agreement between the loads dominated by aerodynamic thrust and force, especially for the no-torsion blade models. Discrepancies were observed in other load channels, partially due to differences in the asymmetric loading of the rotor and partially due to differing closed-loop dynamics, and they will be the subject of future investigations.

17 WIND ENERGY↗

Investigation of Thulium and Other Rare Earth Element Mass Fractions in NIST SRM 1632a Bituminous Coal Reference Material by Quadrupole ICP-MS

Inductively coupled plasma-mass spectrometry after lithium metaborate fusion and digestion was used to measure the rare earth element (REE) mass fractions of several reference materials including NIST SRM 1632a, a historical bituminous Pennsylvania seam coal. While most of the REE mass fractions measured in this study were consistent with the published consensus data, the measured mass fraction of thulium for NIST SRM 1632a was consistently lower compared with the published data. Chondrite normalisation of the published consensus data for NIST SRM 1632a produced a positive thulium anomaly (Tm = 1.78), which is inconsistent with a terrestrial source of sediment. The Normalisation of REE mass fractions collected in this study produced no significant Tm anomaly (Tm = 0.93), which agrees with the sedimentary depositional environment of coal. Therefore, a revised mass fraction of 0.16 mg kg -1 Tm in NIST SRM 1632a is recommended.

58 GEOSCIENCES↗

Ni/NiO Reference Electrode Potential Measurements in Molten CaCl 2 –CaO

A direct oxide reduction (DOR) process is used to reduce PuO 2 to Pu metal via Ca metal. Molten CaCl 2 is commonly used as the electrolyte for this reaction. As the DOR reaction proceeds, CaO accumulates in the salt and must be measured in real-time to know when the reaction has gone to completion. Open circuit potential (OCP) was measured in this report between a reference electrode consisting of Ni/NiO contained in a MgO tube and a tungsten working electrode. Two methods of CaO additions were performed over several experiments, and both methods correlated to a 0.11 to 0.23 V decrease in OCP up to 14.4 wt% CaO. CaO concentrations were separately measured via sampling and acid-base titration. A plot of OCP versus concentration of CaO fits the Nernst equation with the CaO powder additions up to 5.2 wt% and also at the higher end of the CaO pellet concentration range. While the MgO tubes were observed to be structurally stable in the molten salt, scanning electron microscopy and energy dispersive X-ray spectroscopy showed that Mg in the tubes had been partially replaced with Ca.