Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAFETY DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Using supercritical fluids to refine hydrocarbons

This is a method to reactively refine hydrocarbons, such as heavy oils with API gravities of less than 20.degree. and bitumen-like hydrocarbons with viscosities greater than 1000 cp at standard temperature and pressure using a selected fluid at supercritical conditions. The reaction portion of the method delivers lighter weight, more volatile hydrocarbons to an attached contacting device that operates in mixed subcritical or supercritical modes. This separates the reaction products into portions that are viable for use or sale without further conventional refining and hydro-processing techniques. This method produces valuable products with fewer processing steps, lower costs, increased worker safety due to less processing and handling, allow greater opportunity for new oil field development and subsequent positive economic impact, reduce related carbon dioxide, and wastes typical with conventional refineries.

04 OIL SHALES AND TAR SANDS↗

Acoustic sensors for fission gas characterization: R and D skills devoted to innovative instrumentation in MTR, non-destructive devices in hot lab facilities and specific transducers for measurements of LWR rods in nuclear plants

First of all, we will present the main principle of the method. A piezoelectric transducer, driven by a pulse generator, generates the acoustic waves in a cavity that may be the fuel rod or a chamber connected to an instrumented rod. The composition determination consists in measuring the time of flight of the acoustic signal emitted. The pressure can be estimated by a calibration process, above the measurement of the amplitude of the signal. Two projects will then be detailed. The first project consists in the development of advanced instrumentation for in-pile experiments in Material Testing Reactor. It constitutes a main goal for the improvement of the nuclear fuel behavior knowledge. This acoustic method was tested with success during a first experiment called REMORA 3, and the results were used to differentiate helium and fission gas release kinetics under transient operating conditions. This experiment was lead at OSIRIS reactor (CEA Saclay, France). As a first step of the development program, we performed in-pile tests on the most sensitive component, i.e., the piezoelectric transducer. For this purpose, the active part of this sensor has been qualified on gamma and neutron radiations and at high temperature. Various industrial piezo-ceramics were exposed to a high activity Cobalt source for few days. The cumulated dose was ranged from 50 kGy up to 2 MGy. Next, these devices were placed inside a Material Test Reactor to investigate their reliability towards neutron fluence. The final fluence after 150 days of irradiation was up to 1.6.10{sup 21}n/cm{sup 2} (for thermal neutron). Irreversible variations have been measured. Next, a specific sensor has been implemented on an instrumented fuel rod and tested in the frame of a REMORA 3 Irradiation test. It was the first experiment under high mixed, temperature neutron and gamma flux. A first irradiation phase took place in March 2010 in the OSIRIS reactor and in November 2010 for the second step of the irradiation. The instrumented fuel rod incorporating the ultrasonic gas composition sensor was finally irradiated during 2 weeks in nominal conditions. Neutronics calculation will be performed in order to calculate the thermal and fast neutron fluence and the gamma dose absorbed by acoustic sensor. A first evaluation gives a thermal fluence about 4,5.10{sup 19} n/cm{sup 2}, a fast neutrons fluence about 4,5.1018 n/cm{sup 2} and a total gamma dose up to 0,25 MGy The maximal temperature during the irradiation test was about 150 C. Although the ultrasonic sensor appears to be damaged, the optimization of the electrical attack parameters and the development of a new signal processing maintain the measurement feasibility up the end of the irradiation campaign. It was the first time that the composition of fission gas has been monitored all along an irradiation experiment in a MTR, giving access to the gas release kinetics. New researches involve thick film transducers produced by screen-printing process in order to propose piezoelectric structures for harsh temperature and irradiation measurements. The second project consists in the development of a non-destructive device that can be directly applied on a LWR fuel rod. The problem to be solved relates to the measurement of the fission gas pressure and composition in a fuel rod using a non-destructive method. Fuel rod internal pressure is one of the safety criteria applied in nuclear power analyses. This criterion must be verified in order to avoid any fuel-cladding gap reopening risk and therefore any local clad ballooning. Apart from the safety implications, this parameter is also a fuel behaviour indicator and reflects the overall fuel performance in operation, but also during shipping and long-term storage. Rod internal pressure is one criterion amongst others, like cladding corrosion, against which the acceptable fuel burn-up limit is set. A sensor has been achieved in 2007. A full-scale hot cell test of the internal gas pressure and composition measurement by an acoustic sensor was conducted successfully between 2008 and 2010 on 5 high burn-up MOX fuel rods and 2 very high burn-up UO{sub 2} fuel rods in LECA Facility at Cadarache Centre. An improvement of this sensor has been proposed, allowing us to divide by two the uncertainty on the pressure measurement. In the case of hot-cell measurements, viscous liquid can be used to couple the sensor with the rod. For gas content with a pressure exceeding 15 bars and a 10% Xe/Kr ratio, such coupling may reduce relative acoustic method accuracy by ±7% for pressure measurement result and ±0.25 % for the assessment of gas composition. These results make it possible to demonstrate the feasibility of the technique on LWR fuel rods. The transducer and the associated methodology are now operational for non-destructive measurements in hot lab facilities and allow characterising the fission gas without puncturing the fuel rods. Up to now, any other non-destructive method can be proposed. A next step will be the development of an industrial application in a fuel storage pool in order to perform a large number of measurements on a fuel assembly in nuclear plants.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SymPLe 1131: A novel architectural solution for the realization of verifiable digital I and C systems and embedded digital devices - 387

One of the main reasons for the increasing popularity of FPGAs in embedded systems and digital I and C systems is that they provide many of the advantages from both hardware and software components. FPGAs provide configurability approaching that of SW, while at the same time delivering deterministic behavior of pure hardware solutions. However, with regard to Software Common Cause Failures (CCF), the use of FPGAs in digital I and C platforms should not be seen as plug-in remedy for reduction or elimination of CCF. To address CCF, we argue that it is not enough to manage the complexity of an I and C device or system, but we must also have the ability to constrain complexity (as needed) and rigorously reason about execution and device functionality. This paper presents the work done regarding an FPGA overlay architecture called SymPLe. SymPLe is designed to reduce the gap between software and hardware approaches for digital I and C systems and increases deterministic behavior and verifiability of the application, architecture and safety-critical system while reasoning about CCF. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methodology comparison for gamma-heating calculations in material-testing reactors

The Jules Horowitz Reactor (JHR) is a Material-Testing Reactor (MTR) under construction in the south of France at CEA Cadarache (French Alternative Energies and Atomic Energy Commission). It will typically host about 20 simultaneous irradiation experiments in the core and in the beryllium reflector. These experiments will help us better understand the complex phenomena occurring during the accelerated ageing of materials and the irradiation of nuclear fuels. Gamma heating, i.e. photon energy deposition, is mainly responsible for temperature rise in non-fuelled zones of nuclear reactors, including JHR internal structures and irradiation devices. As temperature is a key parameter for physical models describing the behavior of material, accurate control of temperature, and hence gamma heating, is required in irradiation devices and samples in order to perform an advanced suitable analysis of future experimental results. From a broader point of view, JHR global attractiveness as a MTR depends on its ability to monitor experimental parameters with high accuracy, including gamma heating. Strict control of temperature levels is also necessary in terms of safety. As JHR structures are warmed up by gamma heating, they must be appropriately cooled down to prevent creep deformation or melting. Cooling-power sizing is based on calculated levels of gamma heating in the JHR. Due to these safety concerns, accurate calculation of gamma heating with well-controlled bias and associated uncertainty as low as possible is all the more important. There are two main kinds of calculation bias: bias coming from nuclear data on the one hand and bias coming from physical approximations assumed by computer codes and by general calculation route on the other hand. The former must be determined by comparison between calculation and experimental data; the latter by calculation comparisons between codes and between methodologies. In this presentation, we focus on this latter kind of bias. Nuclear heating is represented by the physical quantity called absorbed dose (energy deposition induced by particle-matter interactions, divided by mass). Its calculation with Monte Carlo codes is possible but computationally expensive as it requires transport simulation of charged particles, along with neutrons and photons. For that reason, the calculation of another physical quantity, called KERMA, is often preferred, as KERMA calculation with Monte Carlo codes only requires transport of neutral particles. However, KERMA is only an estimator of the absorbed dose and many conditions must be fulfilled for KERMA to be equal to absorbed dose, including so-called condition of electronic equilibrium. Also, Monte Carlo computations of absorbed dose still present some physical approximations, even though there is only a limited number of them. Some of these approximations are linked to the way how Monte Carlo codes apprehend the transport simulation of charged particles and the productive and destructive interactions between photons, electrons and positrons. There exists a huge variety of electromagnetic shower models which tackle this topic. Differences in the implementation of these models can lead to discrepancies in calculated values of absorbed dose between different Monte Carlo codes. The magnitude of order of such potential discrepancies should be quantified for JHR gamma-heating calculations. We consequently present a two-pronged plan. In a first phase, we intend to perform compared absorbed dose / KERMA Monte Carlo calculations in the JHR. This way, we will study the presence or absence of electronic equilibrium in the different JHR structures and experimental devices and we will give recommendations for the choice of KERMA or absorbed dose when calculating gamma heating in the JHR. In a second phase, we intend to perform compared TRIPOLI4 / MCNP absorbed dose calculations in a simplified JHR-representative geometry. For this comparison, we will use the same nuclear data library for both codes (the European library JEFF3.1.1 and photon library EPDL97) so as to isolate the effects from electromagnetic shower models on absorbed dose calculation. This way, we hope to get insightful feedback on these models and their implementation in Monte Carlo codes. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Cherenkov Video Imaging Allows for the First Visualization of Radiation Therapy in Real Time

Purpose: To determine whether Cherenkov light imaging can visualize radiation therapy in real time during breast radiation therapy. Methods and Materials: An intensified charge-coupled device (CCD) camera was synchronized to the 3.25-μs radiation pulses of the clinical linear accelerator with the intensifier set × 100. Cherenkov images were acquired continuously (2.8 frames/s) during fractionated whole breast irradiation with each frame an accumulation of 100 radiation pulses (approximately 5 monitor units). Results: The first patient images ever created are used to illustrate that Cherenkov emission can be visualized as a video during conditions typical for breast radiation therapy, even with complex treatment plans, mixed energies, and modulated treatment fields. Images were generated correlating to the superficial dose received by the patient and potentially the location of the resulting skin reactions. Major blood vessels are visible in the image, providing the potential to use these as biological landmarks for improved geometric accuracy. The potential for this system to detect radiation therapy misadministrations, which can result from hardware malfunction or patient positioning setup errors during individual fractions, is shown. Conclusions: Cherenkoscopy is a unique method for visualizing surface dose resulting in real-time quality control. We propose that this system could detect radiation therapy errors in everyday clinical practice at a time when these errors can be corrected to result in improved safety and quality of radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aligning lithium metal battery research and development across academia and industry

Successful integration of metallic lithium anodes into secondary batteries could enhance energy density and enable new forms of electrified transportation. However, the outlook for widespread lithium metal adoption in energy storage devices remains mixed. This comes in part from existing gaps in our understanding of the relationships connecting the initial state of lithium, its evolution with cycling, and end-of-life state. It remains important to develop standardized protocols for material and cell characterization, cycling performance, safety, and recycling procedures for lithium metal-based batteries. In February 2023 a cohort of scientists and engineers from academia, national laboratories, and industry gathered to converge on a list of critical challenges and action items to provide better understanding of lithium metal evolution and to enhance academic, governmental, and industrial partnerships to address these challenges. Here, we highlight the major discussion topics revolving around the manufacturing of lithium metal, its related metrology and integration into battery form factors, and best practices testing its electrochemical performance relevant to automotive applications. We introduce a power-controlled discharge testing protocol for research and development cells, in alignment between major automotive stakeholders, that may reveal lithium metal battery dynamics closer to practical driving behavior.

25 ENERGY STORAGE↗

Evaluation of COTS Rad Detection Apps

Mobile applications are currently under distribution to smart phones utilizing the built-in charge coupled-device (CCD) camera as a radiation detector. The CCD detector has a very low but measurable gamma interaction cross section so the mechanism is feasible, especially for higher dose rate environments. Given that in a large release of radioactive material these ‘crowd sourced’ measurements will be put forth for consideration, a testing and evaluation of the accuracy and uncertainty of the Apps is a critical endeavor. Not only is the accuracy of the reported measurement of concern to the immediate user’s safety, a quantitative uncertainty is required for a government response such as the Federal Radiological Monitoring and Assessment Center (FRMAC) to accept the values for consideration in the determination of regions exceeding protective action guidelines. Already, prompted by the Fukushima nuclear material releases, several repositories of this crowd-sourced data have been created (http://japan.failedrobot.com, http://www.stubbytour.com/nuc/index_en.asp, and http://www.rdtn.org) although the question remains as to the reliability of measurements incorporated into these repositories. In cases of conflict between the real-time published crowd-sourced data and governmental protective actions prepared literature should be on-hand documenting why the difference, if any, exists. Four applications for iOS devices were obtained along with hardware to benchmark their performance. Gamma/X-Ray Detector by Stephan Hotto, Geiger Camera by Senscare, and RadioactivityCounter App by Hotray LTD are all the applications available for distribution within the US that utilize the CCD camera sensor for detection of radiation levels. The CellRad app under development by Idaho National Laboratory for the Android platform was evaluated. In addition, iRad Geiger with the associated hardware accessory was also benchmarked. Radiation fields were generated in a Cs-137 JL Shepherd Model 89 shielded calibration range. The accuracy of the exposure rate within the box calibrator is +/- 5% of the system settings and NIST traceable. This is the same calibration unit utilized for calibration of US DOE exposure rate meters. Measurements were performed from 0.2 to 40,000 mR/hr. Included in the following sections are discussions on each of the evaluated applications and their performance in reporting radiation field measurements. Unfortunately the applications do not provide a readily identifiable quality of the measurement in order to produce error bars or even out of range conditions. In general all the CCD based applications had issues detecting consistent measurements in radiation fields less than 5 mR/hr. This is most likely attributable to the electronic noise level on the CCD’s becoming comparable to the signal level due to the ionizing radiation photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanostructured Block Polymer Electrolytes: Tailoring Self-Assembly to Unlock the Potential in Lithium-Ion Batteries

Ion-containing solid block polymer (BP) electrolytes can self-assemble into microphase-separated domains to facilitate the independent optimization of ion conduction and mechanical stability; this assembly behavior has the potential to improve the functionality and safety of lithium-ion batteries over liquid electrolytes to meet future demands (e.g., large capacities and long lifetimes) in various applications. However, significant enhancements in the ionic conductivity and processability of BPs must be realized for BP-based electrolytes to become robust alternatives in commercial devices. Toward this end, the controlled modification of BP electrolytes’ intra-domain (nanometer-scale) and multi-grain (micrometer-scale) structure is one viable approach; intra-domain ion transport and segmental compatibility (related to the effective Flory–Huggins parameter, χ eff ) can be increased by tuning the ion and monomer-segment distributions, and the morphology can be selected such that the multi-grain transport is less sensitive to grain size and orientation.

25 ENERGY STORAGE↗

Plasma–wall interaction studies within the EUROfusion consortium: progress on plasma-facing components development and qualification

The provision of a particle and power exhaust solution which is compatible with first-wall components and edge-plasma conditions is a key area of present-day fusion research and mandatory for a successful operation of ITER and DEMO. The work package plasma-facing components (WP PFC) within the European fusion programme complements with laboratory experiments, i.e. in linear plasma devices, electron and ion beam loading facilities, the studies performed in toroidally confined magnetic devices, such as JET, ASDEX Upgrade, WEST etc. The connection of both groups is done via common physics and engineering studies, including the qualification and specification of plasma-facing components, and by modelling codes that simulate edge-plasma conditions and the plasma–material interaction as well as the study of fundamental processes. WP PFC addresses these critical points in order to ensure reliable and efficient use of conventional, solid PFCs in ITER (Be and W) and DEMO (W and steel) with respect to heat-load capabilities (transient and steady-state heat and particle loads), lifetime estimates (erosion, material mixing and surface morphology), and safety aspects (fuel retention, fuel removal, material migration and dust formation) particularly for quasi-steady-state conditions. Alternative scenarios and concepts (liquid Sn or Li as PFCs) for DEMO are developed and tested in the event that the conventional solution turns out to not be functional. Here, we present an overview of the activities with an emphasis on a few key results: (i) the observed synergistic effects in particle and heat loading of ITER-grade W with the available set of exposition devices on material properties such as roughness, ductility and microstructure; (ii) the progress in understanding of fuel retention, diffusion and outgassing in different W-based materials, including the impact of damage and impurities like N; and (iii), the preferential sputtering of Fe in EUROFER steel providing an in situ W surface and a potential first-wall solution for DEMO.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linear properties of energetic particle driven geodesic acoustic mode

Linear properties of energetic particle driven geodesic acoustic mode (EGAM) in the large helical device plasmas are investigated using a hybrid simulation code for a magnetohydrodynamics fluid interacting with energetic particles. It is found that the EGAM is a global mode with the spatially uniform oscillation frequency despite the spatial variation of the local geodesic acoustic mode frequency. The poloidal mode numbers of poloidal velocity fluctuation, plasma density fluctuation, and magnetic fluctuation are m = 0, 1, and 2, respectively. Oscillation frequency, linear growth rate, and spatial width of EGAM are compared for different physics conditions. The EGAM frequency is proportional to the square root of the plasma temperature. The frequency is lower for higher energetic particle {beta} value. The mode spatial width is larger for larger spatial width of the energetic particle distribution and for the reversed shear safety-factor profile than the normal shear profile. It is also found that the EGAM propagates radially outward in the linearly growing phase, and the propagation speed is slower for the spatially broadened modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrochromic mirror using viologen-anchored nanoparticles

Highlights: • Three types of ECM device were fabricated using viologen-anchored ECDs. • The devices were investigated according to their optical structures. • The anti-reflection material affects the reflectance and the coloration efficiency. • The device design of ECMs is a crucial factor for clear reflected images. - Abstract: Electrochromic mirrors (ECMs) that are used in automobile mirrors need to have high reflectance, a high contrast ratio, and a clear image. In particular, it is critical that distortions of clear images are minimized for safety. Therefore, an ECM is fabricated using viologen-anchored nanoparticles and a magnesium fluoride (MgF{sub 2}) layer with an anti-reflection function. The ECM has approximately 30.42% in the reflectance dynamic range and 125 cm{sup 2}/C high coloration efficiency.

36 MATERIALS SCIENCE↗

Equilibria with incompressible flows from symmetry analysis

We identify and study new nonlinear axisymmetric equilibria with incompressible flow of arbitrary direction satisfying a generalized Grad Shafranov equation by extending the symmetry analysis presented by Cicogna and Pegoraro [Phys. Plasmas 22, 022520 (2015)]. In particular, we construct a typical tokamak D-shaped equilibrium with peaked toroidal current density, monotonically varying safety factor, and sheared electric field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wave Tank Testing Report for Controls Validation of a Heaving Point Absorber

The core objectives of this project is to improve the power capture of three different wave energy conversion (WEC) devices by more than 50% using an advanced control system and validate the attained improvements using wave tank and full scale testing. In parallel, we will bring along the development of a wave prediction system that is required to enable effective control and test it at full scale. The purposes of this report are to: 1. Plan and document the 1/25th scale device testing at the wave-tank facility; 2. Document the test article, setup and methodology, sensor and instrumentation, mooring, electronics, wiring, and data flow and quality assurance; 3. Communicate the testing results between the associated members; 4. Facilitate reviews that will help to ensure all aspects (risk, safety, testing procedures, etc.); 5. Provide a systematic guide to setting up, executing and decommissioning the experiment.

16 TIDAL AND WAVE POWER↗

TU-G-213-00: The International Electrotechnical Commission (IEC): What Is It and Why Should Medical Physicists Care?

The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

60 APPLIED LIFE SCIENCES↗

TU-G-213-01: IEC and US Committee Activities and Organizational Structure

The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

60 APPLIED LIFE SCIENCES↗

TU-G-213-02: IEC Subcommittee 62B (Diagnostic Imaging Equipment): Recent and Active Projects

The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

60 APPLIED LIFE SCIENCES↗

TU-G-213-03: IEC Subcommittee 62C (Equipment for Radiotherapy, Nuclear Medicine and Radiation Dosimetry): Recent and Active Projects

The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

60 APPLIED LIFE SCIENCES↗

Canister Lift Machine Safety Note

The following safety note assesses the structural integrity of a lead screw Lift Machine and provides safety factors for the custom hardware associated with the Lift Machine. The purpose of this machine is to support overflow canisters filled with dense metal powders, allowing vertical movement for seamless canister connection and removal to a piping system. The analysis of the lift machine is to ensure the device can safely raise, support in place, and lower its intended loads when the device is installed. Intended loads are centered and axial, and can reach up to 200 pounds assuming the densest powder intended, Uranium-6 Niobium, with a packing density of 100%.

42 ENGINEERING↗