Search NASA⌕ Search

SEARCH · Search NASA

Results for “SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Iron-Chromium-Aluminum Accident Tolerant Fuel Concept Source Term Accident Sequence Analysis - High Burnup Fuel Source Term Accident Sequence Analysis Supplement

To extend NUREG-1465 and high burnup fuel source term (SAND2023-01313) recommendations, representative radiological releases to containment – patterned after NUREG-1465 – have been evaluated for LWRs utilizing iron-chromium-aluminum (FeCrAl) alloys in place of zirconium-based alloys in major core structures (cladding and fuel canisters) and high burnup fuel with enrichments of 8% and 10% for PWRs and BWRs, respectively. Representative radionuclide releases are generated for this accident tolerant fuel concept by applying non-parametric bootstrap methods to MELCOR simulation results. Accident scenarios considered in this analysis include principle contributors to historical core damage frequency estimates for a range of nuclear reactor technologies representative of the operating U.S.A. fleet of nuclear reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cr-coated Accident Tolerant Fuel Concept Source Term Accident Sequence Analysis - High Burnup Fuel Source Term Accident Sequence Analysis Supplement

To extend NUREG-1465 and high burnup fuel source term (SAND2023-01313) recommendations, representative radiological releases to containment – patterned after NUREG-1465 – have been evaluated for LWRs utilizing the chromium-coating on major zircaloy structures (cladding and fuel canisters) and high burnup fuel with enrichments of 8% and 10% for PWRs and BWRs, respectively. Representative radionuclide releases are generated for this accident tolerant fuel concept by applying non-parametric bootstrap methods to MELCOR simulation results. Accident scenarios considered in this analysis include principle contributors to historical core damage frequency estimates for a range of nuclear reactor technologies representative of the operating U.S.A. fleet of nuclear reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Forward Modeling of Large-scale Structure: An Open-source Approach with Halotools

Here, we present the first stable release of Halotools (v0.2), a community-driven Python package designed to build and test models of the galaxy-halo connection. Halotools provides a modular platform for creating mock universes of galaxies starting from a catalog of dark matter halos obtained from a cosmological simulation. The package supports many of the common forms used to describe galaxy-halo models: the halo occupation distribution (HOD), the conditional luminosity function (CLF), abundance matching, and alternatives to these models that include effects such as environmental quenching or variable galaxy assembly bias. Satellite galaxies can be modeled to live in subhalos, or to follow custom number density profiles within their halos, including spatial and/or velocity bias with respect to the dark matter profile. Here, the package has an optimized toolkit to make mock observations on a synthetic galaxy population, including galaxy clustering, galaxy-galaxy lensing, galaxy group identification, RSD multipoles, void statistics, pairwise velocities and others, allowing direct comparison to observations. Halotools is object-oriented, enabling complex models to be built from a set of simple, interchangeable components, including those of your own creation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mexico City Aerosol Analysis during MILAGRO using High Resolution Aerosol Mass Spectrometry at the Urban Supersite (T0). Part 1: Fine Particle Composition and Organic Source Apportionment

Submicron aerosol was analyzed during the MILAGRO field campaign in March 2006 at the T0 urban supersite in Mexico City with a High-Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS) and complementary instrumentation. Mass concentrations, diurnal cycles, and size distributions of inorganic and organic species are similar to results from the CENICA supersite in April 2003 with organic aerosol (OA) comprising about half of the fine PM mass. Positive Matrix Factorization (PMF) analysis of the high resolution OA spectra identifies three major components: chemically-reduced urban primary emissions (hydrocarbon-like OA, HOA), oxygenated OA (OOA, mostly secondary OA or SOA), and biomass burning OA (BBOA) that correlates with levoglucosan and acetonitrile. BBOA includes several very large plumes from regional fires and likely also some refuse burning.

09 BIOMASS FUELS↗

Source location of the narrowbanded radio bursts at Uranus - Evidence of a cusp source

While Voyager 2 was inbound to Uranus, radio bursts of narrow bandwidth (less than 5 kHz) were detected between 17-116 kHz. These R-X mode bursts, designated n-bursts, were of short duration, tended to occur when the north magnetic pole tipped toward the spacecraft, and increased in occurrence with increasing solar wind density. An explicit determination of the burst source location is presented, based upon fitting the region of detection at high and low frequencies to field-aligned, symmetric cones. The region of good fits was located between the north magnetic pole and the rotational pole, corresponding approximately to the northern polar cusp.

Farrell, W. M.↗

All-Sky Search for Transient Sources near 0.5 MeV with the Burst and Transient Source Experiment (BATSE)

We present a search for bright, transient emission lines near 0.5 MeV in nearly two years of data from the Burst and Transient Source Experiment (BATSE) on the Compton Gamma-Ray Observatory, Such features have been reported from black hole candidates Nova Muscae and 1E 1740.7-2942 and from the Crab, lasting for about 1 day. Our survey covers the whole sky and is sensitive to events with durations from 0.5-3.0 day. No transients are observed, and the systematic errors are low enough that the upper limits are significantly below the fluxes of the two most significant events previously reported.

Smith, D. M.↗

shiftNMFk 1.1: Robust Nonnegative matrix factorization with kmeans clustering and signal shift, for allocation of unknown physical sources, toy version for open sourcing with publications

This code is a toy (short) version of CODE-2016-83. From a general perspective, the code represents an unsupervised adaptive machine learning algorithm that allows efficient and high performance de-mixing and feature extraction of a multitude of non-negative signals mixed and recorded by a network of uncorrelated sensor arrays. The code identifies the number of the mixed original signals and their locations. Further, the code also allows deciphering of signals that have been delayed in regards to the mixing process in each sensor. This code is high customizable and it can be efficiently used for a fast macro-analyses of data. The code is applicable to a plethora of distinct problems: chemical decomposition, pressure transient decomposition, unknown sources/signal allocation, EM signal decomposition. An additional procedure for allocation of the unknown sources is incorporated in the code.

Alexandrov, Boian S.↗

Multi-keV x-ray source development experiments on the National Ignition Facility

We report results from a five shot campaign carried out with Ar-Xe gas-filled targets at the National Ignition Facility (NIF). The targets were shot with {approx_equal}350 kJ of 3{omega} laser energy delivered with a 5 ns trapezoidal laser pulse. We report measured x-ray output from the target in different spectral bands both below and above 1.5 keV photon energies: We find yields of {approx_equal}20.5 kJ/sr with peak x-ray power approaching 4 TW/sr over all energies, as measured for the unique viewing angle of our detector, and {approx_equal}3.6 kJ/sr with peak x-ray power of 1 TW/sr for x-rays with energies >3 keV. This is a laser-to-x-ray conversion efficiency of 13{+-}1.3% for isotropic x-rays with energies >3 keV. Laser energy reflected by the target plasma for both inner and outer-cone beams is measured and found to be small, between 1% and 4% of the drive energy. The energy emitted in hard x-rays (with energies >25 keV) is measured and found to be {approx_equal}1 J/sr. Two-dimensional imaging of the target plasma during the laser pulse confirms a fast, volumetric heating of the entire target, resulting in efficient laser-to-x-ray conversion. Postshot simulations with a two-dimensional radiation-hydrodynamics code reproduce well the observed x-ray flux and fluence, backscattered light, and bulk target motion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Positron generation using laser-wakefield electron sources

Positron generation, using wakefield-accelerated electrons driven into a converter target, was investigated experimentally and through Monte Carlo simulations. Using experimentally measured initial electron distributions from a 60 fs laser system, modeling shows that a collimated wakefield electron beam of moderate energy (50–200 MeV) produces a large number of positrons (~10 7 ), which are emitted from the rear of a mm-scale, high-Z target with divergence angles between 50 and 150 mrad. The large perpendicular momentum of the positrons was found to be dominated by contributions from multiple small angle Coulomb scattering. Positrons were not observed above background noise for a range of targets where simulations indicate a 5–30× increase in the beam charge was necessary to exceed threshold detection. These results provide new understanding to the fundamental limitations of creating narrow-divergence, high-density positron beams from laser-wakefield platforms for use in future laboratory pair plasma experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calcium and lithium ion production for laser ion source

Calcium and lithium ion beams are required by NASA Space Radiation Laboratory at Brookhaven National Laboratory to simulate the effects of cosmic radiation. To identify the difficulties in providing such highly reactive materials as laser targets, both species were experimentally tested. Plate shaped lithium and calcium targets were fabricated to create ablation plasmas with a 6 ns 1064 nm neodymium-doped yttrium aluminum garnet laser. We found significant oxygen contamination in both the Ca and Li high charge state beams due to the rapid oxidation of the surfaces. A large spot size, low power density laser was used to create low charge state beams without scanning the targets. The low charge state Ca beam did not have any apparent oxygen contamination, showing the potential to clean the target entirely of oxide with a low power beam once in the chamber. The Li target was clearly still oxidizing in the chamber after each low power shot. To measure the rate of oxidation, we shot the low power laser at the target repeatedly at 10 s, 30 s, 60 s, and 120 s interval lengths, showing a linear relation between the interval time and the amount of oxygen in the beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stable-carbon isotope ratios for sourcing the nerve-agent precursor methylphosphonic dichloride and its products

The ability to connect a chemical threat agent to a specific batch of a synthetic precursor can provide a fingerprint to contribute to effective forensic investigations. Stable isotope analysis can leverage intrinsic, natural isotopic variability within the molecules of a threat agent to unlock embedded chemical fingerprints in the material. Methylphosphonic dichloride (DC) is a chemical precursor to the nerve agent sarin. It is converted to methylphosphonic difluoride (DF) as part of the sarin synthesis process. We used a suite of commercially available DC stocks to both evaluate the potential for δ13C analysis to be used as a fingerprinting tool in sarin-related investigations and to develop sample preparation techniques (using chemical hydrolysis) that can simplify isotopic analysis of DC and its synthetic products. We demonstrate that natural isotopic variability in DC results in at least three distinct, isotope-resolved clusters within the thirteen stocks we analyzed. Isotopic variability in the carbon feedstock (i.e., methanol) used for DC synthesis is likely inherited by the DC samples we measured. We demonstrate that the hydrolysis of DC and DF to methylphosphonic acid (MPA) can be used as a preparative step for isotopic analysis because the reaction does not impart a measureable isotopic fractionation. MPA is more chemically stable, less toxic, and easier to handle than DC or DF. Further, the hydrolysis method we demonstrated can be applied to a suite of other precursors or to sarin itself, thereby providing a potentially valuable forensic tool.

Moran, James J.↗

Characteristics of rf H{sup -} Ion Source by Using FET Power Source

Characteristics of radio frequency(rf) plasma production are investigated using a FET inverter power supply as an rf generator. The matching circuit in the inverter system is simple compared to a conventional 50 Ohm matching system and only an imaginary part of the impedance of rf transmission should be matched by adjusting operating frequency or capacitance of the circuit. An electron density over 10{sup 18} m{sup -3} is produced in argon plasma with 1 kW rf power. Lower densities are obtained in helium and hydrogen plasmas compared to the argon plasma. Effect of axial magnetic field in driver region is examined. Electron density more than 10{sup 18} m{sup -3} is obtained at the hydrogen gas pressure around 1 Pa with the help of the axial magnetic field.

43 PARTICLE ACCELERATORS↗

Resonant Ionization Laser Ion Source (RILIS) With Improved Selectivity Achieved By Ion Pulse Compression Using In-Source Time-of-flight Technique

This paper describes for the first time the improved selectivity of the RILIS made possible by the time-of-flight (TOF) ion bunch compression. Brief description of the compression principles and some preliminary experimental results are presented. In the off-line experiments short ion peaks of natural Li, Na, K, Tm and Yb are observed as ions leave the RILIS-TOF structure. For Tm the ion peaks of 5 {mu}s half-height duration are detected and 1 {mu}s peaks for Sn are predicted. In view of the repetition rate of the ISOLDE-RILIS lasers it is hoped that the selectivity of Sn isotopes production may be improved as much as 100 employing the RILIS with the TOF ion bunch compression and a gating technique.

74 ATOMIC AND MOLECULAR PHYSICS↗

The electron spectro-microscopy beamline at National Synchrotron Light Source II: A wide photon energy range, micro-focusing beamline for photoelectron spectro-microscopies

A comprehensive optical design for a high-resolution, high-flux, wide-energy range, micro-focused beamline working in the vacuum ultraviolet and soft x-ray photon energy range is proposed. The beamline is to provide monochromatic radiation to three photoelectron microscopes: a full-field x-ray photoelectron emission microscope and two scanning instruments, one dedicated to angle resolved photoemission spectroscopy ({mu}-ARPES) and one for ambient pressure x-ray photoelectron spectroscopy and scanning photoelectron microscopy (AP-XPS/SPEM). Microfocusing is achieved with state of the art elliptical cylinders, obtaining a spot size of 1 {mu}m for ARPES and 0.5 {mu}m for AP-XPS/SPEM. A detailed ray tracing analysis quantitatively evaluates the overall beamline performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New developments in micro-X-ray diffraction and X-ray absorption spectroscopy for high-pressure research at 16-BM-D at the Advanced Photon Source

We report the monochromator and focusing mirrors of the 16-BM-D beamline, which is dedicated to high-pressure research with micro-X-ray diffraction (micro-XRD) and X-ray absorption near edge structure (XANES) (6-45 keV) spectroscopy, have been recently upgraded. Monochromatic X-rays are selected by a Si (111) double-crystal monochromator operated in an artificial channel-cut mode and focused to 5 μm × 5 μm (FWHM) by table-top Kirkpatrick-Baez type mirrors located near the sample stage. The typical X-ray flux is ~5 × 10 8 photons/s at 30 keV. The instrumental resolution, Δq/q max , reaches to 2 × 10 –3 and is tunable through adjustments of the detector distance and X-ray energy. The setup is stable and reproducible, which allows versatile application to various types of experiments including resistive heating and cryogenic cooling as well as ambient temperature compression. Transmission XANES is readily combined with micro-XRD utilizing the fixed-exit feature of the monochromator, which allows combined XRD-XANES measurements at a given sample condition.

47 OTHER INSTRUMENTATION↗