Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

AVT-297 Development of a Framework for Validation of Computational Tools

Design of aerospace vehicles relies on system models. These models rely on validation data to ensure accurate representation of the system. This paper provides an introduction to the problem and an overview of a NATO STO Activity, AVT-297, which developed a framework to determine validation experiments required to support system level models. The goals of the research group were to develop a process to identify a validation database for intended uses of a vehicle system, demonstrate the process on vehicles and document the process. Applying this process to multiple intended uses and collecting this set of validation databases identifies a set of validation experiments that could be applied to the design of multiple vehicles, further reducing the cost and time to develop air and naval vehicles. Four subgroup teams focused on different aspects of the validation database process: two focused on different aspects of a missile, and two focused on different aspects of a fixed-wing mobility transport class vehicle. This resulted in three different processes to decompose the multi-disciplinary problem to identify critical validation data. All four of the teams demonstrated their process on a sample problem demonstrating the benefit of the process.

Validation↗

The Compositional Evolution of C/2012 S1 (ISON) from Ground-Based High-Resolution Infrared Spectroscopy as Part of a Worldwide Observing Campaign

Volatile production rates, relative abundances, rotational temperatures, and spatial distributions in the coma were measured in C/2012 S1 (ISON) using long-slit high-dispersion (lambda/delta lambda approximately 2.5 times 10 (sup 4)) infrared spectroscopy as part of a worldwide observing campaign. Spectra were obtained on Universal Time 2013 October 26 and 28 with NIRSPEC (Near Infrared Spectrometer) at the W.M. Keck Observatory, and Universal Time 2013 November 19 and 20 with CSHELL (Cryogenic Echelle Spectrograph) at the NASA IRTF (Infrared Telescope Facility). H2O was detected on all dates, with production rates increasing markedly from (8.7 plus or minus 1.5) times 10 (sup 27) molecules per second on October 26 (Heliocentric Distance = 1.12 Astronomical Units) to (3.7 plus or minus 0.4) times 10 (sup 29) molecules per second on November 20 (Heliocentric Distance = 0.43 Astronomical Units). Short-term variability of H2O production is also seen as observations on November 19 show an increase in H2O production rate of nearly a factor of two over a period of about 6 hours. C2H6, CH3OH and CH4 abundances in ISON (International Scientific Optical Network) are slightly depleted relative to H2O when compared to mean values for comets measured at infrared wavelengths. On the November dates, C2H2, HCN and OCS abundances relative to H2O appear to be within the range of mean values, whereas H2CO and NH3 were significantly enhanced. There is evidence that the abundances with respect to H2O increased for some species but not others between October 28 (Heliocentric Distance = 1.07 Astronomical Units) and November 19 (Heliocentric Distance = 0.46 Astronomical Units). The high mixing ratios of H2CO to CH3OH and C2H2 to C2H6 on November 19, and changes in the mixing ratios of some species with respect to H2O between October 28 to November 19, indicates compositional changes that may be the result of a transition from sampling radiation-processed outer layers in this dynamically new comet to sampling more pristine natal material as the outer processed layer was increasingly eroded and the thermal wave propagated into the nucleus as the comet approached perihelion for the first time. On November 19 and 20, the spatial distribution for dust appears asymmetric and enhanced in the antisolar direction, whereas spatial distributions for volatiles (excepting CN) appear symmetric with their peaks slightly offset in the sunward direction compared to the dust. Spatial distributions for H2O, HCN, C2H6, C2H2, and H2CO on November 19 show no definitive evidence for significant contributions from extended sources; however, broader spatial distributions for NH3 and OCS may be consistent with extended sources for these species. Abundances of HCN and C2H2 on November 19 and 20 are insufficient to account for reported abundances of CN and C2 in ISON near this time. Differences in HCN and CN spatial distributions are also consistent with HCN as only a minor source of CN in ISON on November 19 as the spatial distribution of CN in the coma suggests a dominant distributed source that is correlated with dust and not volatile release. The spatial distributions for NH3 and NH2 are similar, suggesting that NH3 is the primary source of NH2 with no evidence of a significant dust source of NH2; however, the higher production rates derived for NH3 compared to NH2 on November 19 and 20 remain unexplained. This suggests a more complete analysis that treats NH2 as a distributed source and accounts for its emission mechanism is needed for future work.

Russo, N. Dello↗

The Mars Science Laboratory Organic Check Material

The Organic Check Material (OCM) has been developed for use on the Mars Science Laboratory mission to serve as a sample standard for verification of organic cleanliness and characterization of potential sample alteration as a function of the sample acquisition and portioning process on the Curiosity rover. OCM samples will be acquired using the same procedures for drilling, portioning and delivery as are used to study martian samples with The Sample Analysis at Mars (SAM) instrument suite during MSL surface operations. Because the SAM suite is highly sensitive to organic molecules, the mission can better verify the cleanliness of Curiosity's sample acquisition hardware if a known material can be processed through SAM and compared with the results obtained from martian samples.

Conrad, Pamela G.↗

Dielectric Energy Storage Materials for Space Sensors: Effect of Processing on the Performance

This paper explores the development of innovative materials for the dielectric energy storage for space components. The CaCuN 3 Ti 4 O 12 or CCTO belonging to perovskite family is of interest due to its colossal dielectric constant. It was demonstrated that materials synthesized at low temperature show nonequilibrium state and exhibit differences in the dielectric and resistivity values. The goal is to obtain high dielectric constant along with high resistivity values for achieving enhanced breakdown voltage. By using other members of the perovskite structures, it was demonstrated that similar colossal dielectric constant is observed and is dependent on processing methods. We have used heterovalent and dissimilar sized atom to replace Ca +2 ion. Accordingly, we replaced Ca +2 ion with heavy Ga +3 ion and developed gallium-based material system, Ga 2/3 Cu 3 Ti 4 O 12 . Following successful synthesis, we measured its dielectric constant and resistivity and compared with CCTO material system. Results of five sets of samples showed that lower temperature processing demonstrated mechanism of grain growth, but due to copper flow in high temperature processed samples dielectric constant and resistivity values were different.

Dielectric Energy↗

Exploration of the Habitability of Mars with the SAM Suite Investigation on the 2009 Mars Science Laboratory

The 2009 Mars Science Laboratory (MSL) with a substantially larger payload capability that any other Mars rover, to date, is designed to quantitatively assess a local region on Mars as a potential habitat for present or past life. Its goals are (1) to assess past or present biological potential of a target environment, (2) to characterize geology and geochemistry at the MSL landing site, and (3) to investigate planetary processes that influence habitability. The Sample Analysis at Mars (SAM) Suite, in its final stages of integration and test, enables a sensitive search for organic molecules and chemical and isotopic analysis of martian volatiles. MSL contact and remote surface and subsurface survey Instruments establish context for these measurements and facilitate sample identification and selection. The SAM instruments are a gas chromatograph (GC), a mass spectrometer (MS), and a tunable laser spectrometer (TLS). These together with supporting sample manipulation and gas processing devices are designed to analyze either the atmospheric composition or gases extracted from solid phase samples such as rocks and fines. For example, one of the core SAM experiment sequences heats a small powdered sample of a Mars rock or soil from ambient to -1300 K in a controlled manner while continuously monitoring evolved gases. This is followed by GCMS analysis of released organics. The general chemical survey is complemented by a specific search for molecular classes that may be relevant to life including atmospheric methane and its carbon isotope with the TLS and biomarkers with the GCMS.

Mahaffy, P. R.↗

Reduction of Sample Rotation in Electrostatic Levitation

In many containerless processing systems, control of sample rotation is an important issue. Sample rotation is even more important for microgravity containerless processing systems, where the centrifugal acceleration can approach 1 g for even a small rotation rate. Prior work on rotation control by Rhim focused on driving the sample rotation at a controlled rate for droplet dynamics experiments and measurement of electrical conductivity. His technique allows controlled, fast rotation, but for many microgravity experiments the goal is zero rotation. To minimize sample rotation, two approaches are apparent: first, to identify and balance or eliminate the driving forces for undesired sample rotation, or second, implement a feedback-based rotation control loop in parallel with the position control loop. In this work, we have taken the first approach. To minimize sample rotation, the simplest approach is to identify and balance or eliminate the driving forces for undesired sample rotation. Our experiments show that the dominant driving force for rotation of machined Zr spheres in the MSFC ESL is photon pressure from the heating laser. Experimental results showing the correlation between heating power and torque are compared to theoretical predictions, and a strategy for minimizing the torque due to photon pressure is presented.

Hyers, R. W↗

Experimental Methods in Reduced-gravity Soldering Research

The National Center for Microgravity Research, NASA Glenn Research Center, and NASA Johnson Space Center are conducting an experimental program to explore the influence of reduced gravity environments on the soldering process. An improved understanding of the effects of the acceleration environment is important to application of soldering during current and future human space missions. Solder joint characteristics that are being considered include solder fillet geometry, porosity, and microstructural features. Both through-hole and surface mounted devices are being investigated. This paper focuses on the experimental methodology employed in this project and the results of macroscopic sample examination. The specific soldering process, sample configurations, materials, and equipment were selected to be consistent with those currently on-orbit. Other apparatus was incorporated to meet requirements imposed by operation onboard NASA's KC-135 research aircraft and instrumentation was provided to monitor both the atmospheric and acceleration environments. The contingent of test operators was selected to include both highly skilled technicians and less skilled individuals to provide a population cross-section that would be representative of the skill mix that might be encountered in space mission crews.

Pettegrew, Richard D.↗

Calibration and Sequence Development Status for the Sample Analysis at Mars Investigation on the Mars Science Laboratory

The measurement goals of the Sample Analysis at Mars (SAM) instrument suite on the "Curiosity" Rover of the Mars Science Laboratory (MSL) include chemical and isotopic analysis of organic and inorganic volatiles for both atmospheric and solid samples [1,2]. SAM directly supports the ambitious goals of the MSL mission to provide a quantitative assessment of habitability and preservation in Gale crater by means of a range of chemical and geological measurements [3]. The SAM FM combined calibration and environmental testing took place primarily in 2010 with a limited set of tests implemented after integration into the rover in January 2011. The scope of SAM FM testing was limited both to preserve SAM consumables such as life time of its electromechanical elements and to minimize the level of terrestrial contamination in the SAM instrument. A more comprehensive calibration of a SAM-like suite of instruments will be implemented in 2012 with calibration runs planned for the SAM testbed. The SAM Testbed is nearly identical to the SAM FM and operates in a ambient pressure chamber. The SAM Instrument Suite: SAM's instruments are a Quadrupole Mass Spectrometer (QMS), a 6-column Gas Chromatograph (GC), and a 2-channel Tunable Laser Spectrometer (TLS). Gas Chromatography Mass Spectrometry is designed for identification of even trace organic compounds. The TLS [5] secures the C, H, and O isotopic composition in carbon dioxide, water, and methane. Sieved materials are delivered from the MSL sample acquisition and processing system to one of68 cups of the Sample Manipulation System (SMS). 59 of these cups are fabricated from inert quartz. After sample delivery, a cup is inserted into one of 2 ovens for evolved gas analysis (EGA ambient to >9500C) by the QMS and TLS. A portion of the gas released can be trapped and subsequently analyzed by GCMS. Nine sealed cups contain liquid solvents and chemical derivatization or thermochemolysis agents to extract and transform polar molecules such as amino acids, nucleobases, and carboxylic acids into compounds that are sufficiently volatile to transmit through the GC columns. The remaining 6 cups contain calibrants. SAM FM Calibration Overview: The SAM FM calibration in the Mars chamber employed a variety of pure gases, gas mixtures, and solid materials. Isotope calibration runs for the TLS utilized 13C enriched C02 standards and 0 enriched CH4. A variety of fluorocarbon compounds that spanned the entire mass range of the QMS as well as C3-C6 hydrocarbons were utilized for calibration of the GCMS. Solid samples consisting of a mixture of calcite, melanterite, and inert silica glass either doped or not with fluorocarbons were introduced into the SAM FM cups through the SAM inlet funnel/tube system.

Mahaffy, Paul R.↗

NASA's Rodent Research Project: Validation of Capabilities for Conducting Long Duration Experiments in Space

Research using rodents is an essential tool for advancing biomedical research on Earth and in space. Prior rodent experiments on the Shuttle were limited by the short flight duration. The International Space Station (ISS) provides a new platform for conducting rodent experiments under long duration conditions. Rodent Research (RR)-1 was conducted to validate flight hardware, operations, and science capabilities that were developed at the NASA Ames Research Center. Twenty C57BL6J adult female mice were launched on Sept 21, 2014 in a Dragon Capsule (SpaceX-4), then transferred to the ISS for a total time of 21-22 days (10 commercial mice) or 37 days (10 validation mice). Tissues collected on-orbit were either rapidly frozen or preserved in RNAlater at -80C (n2group) until their return to Earth. Remaining carcasses on-orbit were rapidly frozen for dissection post-flight. The three controls groups at Kennedy Space Center consisted of: Basal mice euthanized at the time of launch, Vivarium controls housed in standard cages, and Ground Controls (GC) housed in flight hardware within an environmental chamber. Upon return to Earth, there were no differences in body weights between Flight (FLT) and GC at the end of the 37 days in space. Liver enzyme activity levels of FLT mice and all control mice were similar in magnitude to those of the samples that were processed under optimal conditions in the laboratory. Liver samples dissected on-orbit yielded high quality RNA (RIN8.99+-0.59, n7). Liver samples dissected post-flight from the intact, frozen FLT carcasses yielded RIN of 7.27 +- 0.52 (n6). Additionally, wet weights of various tissues were measured. Adrenal glands and spleen showed no significant differences in FLT compared to GC although thymus and livers weights were significantly greater in FLT compared to GC. Over 3,000 tissue aliquots collected post-flight from the four groups of mice were deposited into the Ames Life Science Data Archives for future Biospecimen Sharing Program. Together, the RR validation flight successfully demonstrates the capability to support long-duration experimentation on the ISS to achieve both basic science and biomedical objectives.

spaceflight↗

Landsat D Thematic Mapper image resampling for scan geometry correction

The Landsat D system is described, and the geometric correction processing for the Thematic Mapper (TM) is reviewed. The resampling procedure (the generation of a TM output image) is analyzed with emphasis on the effect of sampling geometry on output image. Effects of scan gaps and spacecraft jitter on output image are studied by means of a simulation of the sampling and resampling processes for three sampling geometries. Visual inspection of the resampling results shows that the resampling algorithm works excellently under all conditions and that distortion is visible only in the rare case of large gaps between scans.

Prakash, A.↗

Tape Cassette Bacteria Detection System

The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.

Source record↗

Satellite Sampling and Retrieval Errors in Regional Monthly Rain Estimates from TMI AMSR-E, SSM/I, AMSU-B and the TRMM PR

Passive and active microwave rain sensors onboard earth-orbiting satellites estimate monthly rainfall from the instantaneous rain statistics collected during satellite overpasses. It is well known that climate-scale rain estimates from meteorological satellites incur sampling errors resulting from the process of discrete temporal sampling and statistical averaging. Sampling and retrieval errors ultimately become entangled in the estimation of the mean monthly rain rate. The sampling component of the error budget effectively introduces statistical noise into climate-scale rain estimates that obscure the error component associated with the instantaneous rain retrieval. Estimating the accuracy of the retrievals on monthly scales therefore necessitates a decomposition of the total error budget into sampling and retrieval error quantities. This paper presents results from a statistical evaluation of the sampling and retrieval errors for five different space-borne rain sensors on board nine orbiting satellites. Using an error decomposition methodology developed by one of the authors, sampling and retrieval errors were estimated at 0.25 resolution within 150 km of ground-based weather radars located at Kwajalein, Marshall Islands and Melbourne, Florida. Error and bias statistics were calculated according to the land, ocean and coast classifications of the surface terrain mask developed for the Goddard Profiling (GPROF) rain algorithm. Variations in the comparative error statistics are attributed to various factors related to differences in the swath geometry of each rain sensor, the orbital and instrument characteristics of the satellite and the regional climatology. The most significant result from this study found that each of the satellites incurred negative longterm oceanic retrieval biases of 10 to 30%.

Fisher, Brad↗

Thermophysical Property Measurement and Materials Research in the NASA/MSFC Electrostatic Levitator

Containerless processing is an important tool for thermophysical property measurements and materials research. The freedom from a crucible allows processing of liquid materials in a metastable undercooled state, as well as allowing processing of high temperature and highly reactive melts. Electrostatic levitation (ESL) is a containerless method which provides a number of unique advantages, including the decoupling of positioning force from sample heating, the ability to operate in ultra-high vacuum or at moderate gas pressure (approximately 3 atm), and the ability to process non-conducting materials. ESL also has the potential to reduce internal flow velocities below those possible with electromagnetic, acoustic, or aero-acoustic techniques. The ESL facility at NASA's Marshall Space Flight Center (MSFC) is in use for thermophysical property measurements and materials research by a number of different internal and external investigators. The methods for obtaining access to the facility, as well as a summary of current capabilities and some future directions will be discussed. In electrostatic levitation, the acceleration of gravity (or residual acceleration in reduced gravity) is opposed by the action of an applied electric field on a charged sample. This positioning method is applicable to any material which can be electrically charged, whether solid or liquid, conducting, or insulating. Because the position of the sample is unstable, a 3-dimensional active control loop rapidly adjusts the applied field to maintain levitation and minimize motion of the sample. Heating lasers melt the sample, and may be adjusted to maintain specified thermal profiles. Microgravity allows electrostatic levitation to work even more effectively. With the need to cancel less than 1 milli-g, the applied field required is reduced from approximately 10 MV/m to approximately 10 kV/m. Alternatively, a microgravity ESL can position larger samples than is possible on the ground, or it can position samples which maintain their charge poorly. Microgravity also reduces the effects of buoyant convection and sedimentation. In the MSFC ESL, many different classes of experiments and measurements have been demonstrated in collaboration with many investigators. These capabilities include heat capacity measurement, phase diagram determination, and nucleation and growth experiments including nucleation rate, TTT curves, and phase selection. We have demonstrated the capability of triggering recalescence of an undercooled liquid sample without loss of levitation. Currently under development are techniques for measuring the surface tension, viscosity, and density of levitated samples, as well as other thermophysical properties. Expanded levitation capabilities including various gas environments for sample processing, sample rotation control and management of thermal gradients are under development for the MSFC ESL. Containerless processing allows research on materials which may not be processed any other way. Electrostatic levitation extends the range of containerless processing to include many materials and classes of materials which cannot be processed by conventional electromagnetic, acoustic, or aerodynamic levitation techniques.

Rogers, Jan↗

Analysis Of Delays In Simulation Of Flight

Report presents analysis of delays in transport of signals through various subsystems and components of flight-simulation system. Addresses all parts of simulation process and system, from analog-to-digital conversion and sampling of pilot's command input, through multiple sampling rate digital processing via transfer-function mathematical models of responses of simulated aircraft and of simulation system itself, to system output sampled at same rate as pilot's command input.

Mcfarland, R. E.↗

Study on the applicability of a precise, accurate method for rapid evaluation of engine and lubricant performance

The development of a procedure for obtaining data related to wear metal determinations in used lubricants is discussed. The procedure makes it possible to obtain rapid, simultaneous determinations of a number of wear metals at levels of parts per thousand to low parts per billion using a small amount of sample. The electrode assembly and instrumentation used in the process are described. Samples of data obtained from tests conducted under controlled conditions are tabulated.

Kinard, J. T.↗

Bioprocessing in Microgravity: Applications of Continuous Flow Electrophoresis to Rat Anterior Pituitary Particles

In this report we describe the results of a continuous flow electrophoresis (CFE) experiment done on STS-65 in which we tested the idea that intracellular growth hormone (GH) particles contained in a cell lysate prepared from cultured rat anterior pituitary cells in microgravity might have different electrophoretic mobilities from those in a synchronous ground control cell lysate. Collectively, the results suggested that CFE processing in microgravity was better than on earth; more samples could be processed at a time (6 x) and more variant forms of GH molecules could be resolved as well. We had also hoped to carry out a pituitary cell CFE experiment, but failure of the hardware required that the actual cell electrophoresis trials be done on earth shortly after Shuttle landing. Data from these experiments showed that space-flown cells possessed a higher electrophoretic mobility than ground control cells, thereby offering evidence for the idea that exposure of cultured cells to microgravity can change their net surface charge-density especially when the cells are fed. Collectively, the results from this pituitary cell experiment document the advantage of using coupled cell culture and CFE techniques in the microgravity environment.

Hymer, W. C.↗

Software for a GPS-Reflection Remote-Sensing System

A special-purpose software Global Positioning System (GPS) receiver designed for remote sensing with reflected GPS signals is described in Delay/Doppler-Mapping GPS-Reflection Remote-Sensing System (NPO-30385), which appears elsewhere in this issue of NASA Tech Briefs. The input accepted by this program comprises raw (open-loop) digitized GPS signals sampled at a rate of about 20 MHz. The program processes the data samples to perform the following functions: detection of signals; tracking of phases and delays; mapping of delay, Doppler, and delay/Doppler waveforms; dual-frequency processing; coherent integrations as short as 125 s; decoding of navigation messages; and precise time tagging of observable quantities. The software can perform these functions on all detectable satellite signals without dead time. Open-loop data collected over water, land, or ice and processed by this software can be further processed to extract geophysical information. Possible examples include mean sea height, wind speed and direction, and significant wave height (for observations over the ocean); bistatic-radar terrain images and measures of soil moisture and biomass (for observations over land); and estimates of ice age, thickness, and surface density (for observations over ice).

Lowe, Stephen↗

Optical vibrational spectroscopic signatures related to U 3 O 8 production processes

Uranium ore concentrates are materials found early within the nuclear fuel cycle and contain high concentrations of uranium in an easily transported form, making the concentrates a likely target for illegal diversion. These concentrates are typically converted to U 3 O 8 for further processing and, therefore, may lose specific physicochemical characteristics in determining the materials’ source and processing history. In this work, we explore the Raman spectra of eight oxide samples produced from various uranium ore concentrates and processing pathways to examine the presence of spectroscopic signatures relating to each sample's process history. Samples produced from amine extraction and dialkylphosphoric acid extraction processes show unique characteristics due to high concentrations of α-UO 3 , whereas samples calcinated from metallic diuranates do not form pure α-U 3 O 8 because of metallic ion inclusions. Pure α-U 3 O 8 oxide samples are obtained through calcination of ammonium diuranate, ammonium uranyl carbonate, and metastudtite intermediates. The Raman spectra of these oxide samples show close agreement with pristine α-U 3 O 8 spectra. However, deviations from the pristine spectra are observed in the 300–460 cm -1 spectral range. In conclusion, these deviations are unique identifying signatures that were likely created by lasting effects from the process history. Spectral center of mass calculations indicate grouping of samples based on processing history.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗