Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Snowmass Instrumentation Frontier IF08 Topical Group Report: Noble Element Detectors

Particle detectors making use of noble elements in gaseous, liquid, or solid phases are prevalent in neutrino and dark matter experiments and are also used to a lesser extent in collider-based particle physics experiments. These experiments take advantage of both the very large, ultra-pure target volumes achievable and the multiple observable signal pathways possible in noble-element based particle detectors. As these experiments seek to increase their sensitivity, novel and improved technologies will be needed to enhance the precision of their measurements and to broaden the reach of their physics programs. The areas of R&D in noble element instrumentation that have been identified by the HEP community in the Snowmass process are highlighted by five key messages: IF08-1) Enhance and combine existing modalities (scintillation and electron drift) to increase signal-to-noise and reconstruction fidelity; IF08-2) Develop new modalities for signal detection in noble elements, including methods based on ion drift, metastable fluids, solid-phase detectors and dissolved targets. Collaborative and blue-sky R&D should also be supported to enable advances in this area; IF08-3) Improve the understanding of detector microphysics and calibrate detector response in new signal regimes; IF08-4) Address challenges in scaling technologies, including material purification, background mitigation, large-area readout, and magnetization; and IF08-5) Train the next generation of researchers, using fast-turnaround instrumentation projects to provide the design-through-result training no longer possible in very-large-scale experiments. This topical group report identifies and documents recent developments and future needs for noble element detector technologies. In addition, we highlight the opportunity that this area of research provides for continued training of the next generation of scientists.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Dark Machines Anomaly Score Challenge: Benchmark Data and Model Independent Event Classification for the Large Hadron Collider

We describe the outcome of a data challenge conducted as part of the Dark Machines (https://www.darkmachines.org) initiative and the Les Houches 2019 workshop on Physics at TeV colliders. The challenged aims to detect signals of new physics at the Large Hadron Collider (LHC) using unsupervised machine learning algorithms. First, we propose how an anomaly score could be implemented to define model-independent signal regions in LHC searches. We define and describe a large benchmark dataset, consisting of >1 billion simulated LHC events corresponding to 10\, fb^{-1} 10 f b − 1 of proton-proton collisions at a center-of-mass energy of 13 TeV. We then review a wide range of anomaly detection and density estimation algorithms, developed in the context of the data challenge, and we measure their performance in a set of realistic analysis environments. We draw a number of useful conclusions that will aid the development of unsupervised new physics searches during the third run of the LHC, and provide our benchmark dataset for future studies at https://www.phenoMLdata.org. Code to reproduce the analysis is provided at https://github.com/bostdiek/DarkMachines-UnsupervisedChallenge.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determination of a Limited Scope Network's Lightning Detection Efficiency

This paper outlines a modeling technique to map lightning detection efficiency variations over a region surveyed by a sparse array of ground based detectors. A reliable flash peak current distribution (PCD) for the region serves as the technique's base. This distribution is recast as an event probability distribution function. The technique then uses the PCD together with information regarding: site signal detection thresholds, type of solution algorithm used, and range attenuation; to formulate the probability that a flash at a specified location will yield a solution. Applying this technique to the full region produces detection efficiency contour maps specific to the parameters employed. These contours facilitate a comparative analysis of each parameter's effect on the network's detection efficiency. In an alternate application, this modeling technique gives an estimate of the number, strength, and distribution of events going undetected. This approach leads to a variety of event density contour maps. This application is also illustrated. The technique's base PCD can be empirical or analytical. A process for formulating an empirical PCD specific to the region and network being studied is presented. A new method for producing an analytical representation of the empirical PCD is also introduced.

Rompala, John T.↗

High-stability compact atomic clock based on isotropic laser cooling

We present a compact cold-atom clock configuration where isotropic laser cooling, microwave interrogation, and clock signal detection are successively performed inside a spherical microwave cavity. For ground operation, a typical Ramsey fringe width of 20 Hz has been demonstrated, limited by the atom cloud's free fall in the cavity. The isotropic cooling light's disordered properties provide a large and stable number of cold atoms, leading to a high signal-to-noise ratio limited by atomic shot noise. A relative frequency stability of 2.2x10{sup -13{tau}-1/2} has been achieved, averaged down to 4x10{sup -15} after 5x10{sup 3} s of integration. Development of such a high-performance compact clock is of major relevance for on-board applications, such as satellite-positioning systems. As a cesium clock, it opens the door to a new generation of compact primary standards and timekeeping devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electroacoustic Excitation of Spin Waves and Their Detection due to the Inverse Spin Hall Effect

Abstract—In this paper, we present theoretical and experimental results on the excitation and detection of spin waves and spin currents in multifrequency bulk acoustic wave resonators containing iron–yttrium garnet (YIG) films in contact with the Pt film. Acoustically excited magnetic precession under the resonator conditions was established to produce spin pumping that also has a resonance character. A significant asymmetry in the frequency dependence of the voltage signal detected on the Pt film is revealed with respect to the frequency of the magnetoelastic resonance and is confirmed by theoretical calculations. Acoustic resonator spectroscopy in combination with the electric detection of magnetic dynamics using the inverse spin Hall effect is shown to be of interest for studying the dispersion of spin waves, as well as magnetic and magnetoelastic parameters of ferromagnetic films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Environmentally selected WIMP dark matter with high-scale supersymmetry breaking

We explore the possibility that both the weak scale and the thermal relic dark matter abundance are environmentally selected in a multiverse. An underlying supersymmetric theory containing the states of the minimal supersymmetric standard model (MSSM) and singlets, with supersymmetry and R symmetry broken at unified scales, has just two realistic low-energy effective theories. One theory (SM+w-tilde) is the standard model augmented only by the wino, having a mass near 3 TeV, and has a Higgs boson mass in the range of (127-142) GeV. The other theory (SM+h-tilde/s-tilde) has Higgsinos and a singlino added to the standard model. The Higgs boson mass depends on the single new Yukawa coupling of the theory, y, and is near 141 GeV for small y but grows to be as large as 210 GeV as this new coupling approaches strong coupling at high energies. Much of the parameter space of this theory will be probed by direct detection searches for dark matter that push 2 orders of magnitude below the present bounds; furthermore, the dark matter mass and cross section on nucleons are correlated with the Higgs boson mass. The indirect detection signal of monochromatic photons from the Galactic center is computed, and the range of parameters that may be accessible to LHC searches for trilepton events is explored. Taking a broader view, allowing the possibility of R symmetry protection to the TeV scale or axion dark matter, we find four more theories: (SM+axion), two versions of split supersymmetry, and the E-MSSM, where a little supersymmetric hierarchy is predicted. The special Higgs mass value of (141{+-}2) GeV appears in symmetry limits of three of the six theories, (SM+axion), (SM+w-tilde), and (SM+h-tilde/s-tilde), motivating a comparison of other signals of these three theories.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nonenzymatic catalytic signal amplification for nucleic acid hybridization assays

Devices, methods, and kits for amplifying the signal from hybridization reactions between nucleic acid probes and their cognate targets are presented. The devices provide partially-duplexed, immobilized probe complexes, spatially separate from and separately addressable from immobilized docking strands. Cognate target acts catalytically to transfer probe from the site of probe complex immobilization to the site of immobilized docking strand, generating a detectable signal. The methods and kits of the present invention may be used to identify the presence of cognate target in a fluid sample.

Fan, Wenhong↗

Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs

Crewmembers returning from long-duration space flight face significant challenges due to the microgravity-induced inappropriate adaptations in balance/sensorimotor function. The Neuroscience Laboratory at JSC is developing a method based on stochastic resonance to enhance the brain's ability to detect signals from the balance organs of the inner ear and use them for rapid improvement in balance skill, especially when combined with balance training exercises. This method involves a stimulus delivery system that is wearable/portable and provides imperceptible electrical stimulation to the balance organs of the human body. Stochastic resonance (SR) is a phenomenon whereby the response of a nonlinear system to a weak periodic input signal is optimized by the presence of a particular non-zero level of noise. This phenomenon of SR is based on the concept of maximizing the flow of information through a system by a non-zero level of noise. Application of imperceptible SR noise coupled with sensory input in humans has been shown to improve motor, cardiovascular, visual, hearing, and balance functions. SR increases contrast sensitivity and luminance detection; lowers the absolute threshold for tone detection in normal hearing individuals; improves homeostatic function in the human blood pressure regulatory system; improves noise-enhanced muscle spindle function; and improves detection of weak tactile stimuli using mechanical or electrical stimulation. SR noise has been shown to improve postural control when applied as mechanical noise to the soles of the feet, or when applied as electrical noise at the knee and to the back muscles. SR using imperceptible stochastic electrical stimulation of the vestibular system (stochastic vestibular stimulation, SVS) applied to normal subjects has shown to improve the degree of association between the weak input periodic signals introduced via venous blood pressure receptors and the heart-rate responses. Also, application of SVS over 24 hours improves the long-term heart-rate dynamics and motor responsiveness as indicated by daytime trunk activity measurements in patients with multi-system atrophy, Parkinson s disease, or both, including patients who were unresponsive to standard therapy for Parkinson s disease. Recent studies conducted at the NASA JSC Neurosciences Laboratories showed that imperceptible SVS, when applied to normal young healthy subjects, leads to significantly improved balance performance during postural disturbances on unstable compliant surfaces. These studies have shown the benefit of SR noise characteristic optimization with imperceptible SVS in the frequency range of 0-30 Hz, and amplitudes of stimulation have ranged from 100 to 400 microamperes.

Bloomberg, Jacob↗

Evaluating Biosignatures for Life Detection

The goal here is to develop a conceptual framework for evaluating the ability of different biosignatures to provide evidence for the presence of life in planned missions or observational studies. The focus is on intrinsic characteristics of biosignatures in a given space environment rather than on their detection, which depends on the current state of technology. Suitable evaluation procedures are based on an extensive body of previous work on related problems in which different options are evaluated to make decisions in business, engineering, medical fields and social or political arena. In these cases, three approaches have proven to be particularly useful. Two of them, signal detection theory (SDT) and Bayesian hypothesis testing are based on probabilities. The third approach, multi-attribute utility (MAU) is based on utility theory.

Pohorille, Andrew↗

Polymers in solar energy utilization

A laser photoacoustic technique (LPAT) has been verified for performing accelerated life testing of outdoor photooxidation of polymeric materials used in solar energy applications. Samples of the material under test are placed in a chamber with a sensitive microphone, then exposed to chopped laser radiation. The sample absorbs the light and converts it to heat by a nonradiative deexcitation process, thereby reducing pressure fluctuations within the cell. The acoustic signal detected by the microphone is directly proportional to the amount of light absorbed by the specimen. Tests were performed with samples of ethylene/methylacrylate copolymer (EMA) reprecipitated from hot cyclohexane, compressed, and molded into thin (25-50 microns) films. The films were exposed outdoors and sampled by LPAT weekly. The linearity of the light absorbed with respect to the acoustic signal was verified.Correlations were established between the photoacoustic behavior of the materials aged outdoors and the same kinds of samples cooled and heated in a controlled environment reactor. The reactor tests were validated for predicting outdoor exosures up to 55 days.

Liang, R. H.↗

A theoretical analysis of the MSFC holographic correlation system

A theoretical analysis was completed for the correlation output signal for the MSFC holographic correlation filtering system. Under appropriate assumptions, the correlation output was derived as a function of the roughness of the tested surface, the displacement of the illuminated area of the test surface, the characteristics of the optical components used in the system, and the system configuration. In addition, an approximate relationship between the displacement of the detected signal (which is focused on the photomultiplier tube) and the displacement of the illuminated area on the test surface was also derived.

Liu, H. K.↗

An active drop counting device using condenser microphone for superheated emulsion detector

An active device for superheated emulsion detector is described. A capacitive diaphragm sensor or condenser microphone is used to convert the acoustic pulse of drop nucleation to electrical signal. An active peak detector is included in the circuit to avoid multiple triggering of the counter. The counts are finally recorded by a microprocessor based data acquisition system. Genuine triggers, missed by the sensor, were studied using a simulated clock pulse. The neutron energy spectrum of {sup 252}Cf fission neutron source was measured using the device with R114 as the sensitive liquid and compared with the calculated fission neutron energy spectrum of {sup 252}Cf. Frequency analysis of the detected signals was also carried out.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On Certain New Methodology for Reducing Sensor and Readout Electronics Circuitry Noise in Digital Domain

NASA Hubble Space Telescope (HST) and upcoming cosmology science missions carry instruments with multiple focal planes populated with many large sensor detector arrays. These sensors are passively cooled to low temperatures for low-level light (L3) and near-infrared (NIR) signal detection, and the sensor readout electronics circuitry must perform at extremely low noise levels to enable new required science measurements. Because we are at the technological edge of enhanced performance for sensors and readout electronics circuitry, as determined by thermal noise level at given temperature in analog domain, we must find new ways of further compensating for the noise in the signal digital domain. To facilitate this new approach, state-of-the-art sensors are augmented at their array hardware boundaries by non-illuminated reference pixels, which can be used to reduce noise attributed to sensors. There are a few proposed methodologies of processing in the digital domain the information carried by reference pixels, as employed by the Hubble Space Telescope and the James Webb Space Telescope Projects. These methods involve using spatial and temporal statistical parameters derived from boundary reference pixel information to enhance the active (non-reference) pixel signals. To make a step beyond this heritage methodology, we apply the NASA-developed technology known as the Hilbert- Huang Transform Data Processing System (HHT-DPS) for reference pixel information processing and its utilization in reconfigurable hardware on-board a spaceflight instrument or post-processing on the ground. The methodology examines signal processing for a 2-D domain, in which high-variance components of the thermal noise are carried by both active and reference pixels, similar to that in processing of low-voltage differential signals and subtraction of a single analog reference pixel from all active pixels on the sensor. Heritage methods using the aforementioned statistical parameters in the digital domain (such as statistical averaging of the reference pixels themselves) zeroes out the high-variance components, and the counterpart components in the active pixels remain uncorrected. This paper describes how the new methodology was demonstrated through analysis of fast-varying noise components using the Hilbert-Huang Transform Data Processing System tool (HHT-DPS) developed at NASA and the high-level programming language MATLAB (Trademark of MathWorks Inc.), as well as alternative methods for correcting for the high-variance noise component, using an HgCdTe sensor data. The NASA Hubble Space Telescope data post-processing, as well as future deep-space cosmology projects on-board instrument data processing from all the sensor channels, would benefit from this effort.

Kizhner, Semion↗

Performance characterization of a MVCT scanner using multislice thick, segmented cadmium tungstate-photodiode detectors

Purpose: Megavoltage computed tomography (MVCT) and megavoltage cone beam computed tomography (MVCBCT) can be used for visualizing anatomical structures prior to radiation therapy treatments to assist in patient setup and target localization. These systems are less susceptible to metal artifacts and provide better CT number linearity than conventional CT scanners. However, their contrast is limited by the properties of the megavoltage photons and the low detective quantum efficiency (DQE) of flat panel detector systems currently available. By using higher DQE, thick, segmented cadmium tungstate detectors, the authors can improve the low contrast detectability of a MVCT system. This in turn would permit greater soft tissue visualization for a given radiation dose, allowing MVCT to be used in more clinical situations. Methods: This article describes the evaluation of our prototype system that uses thick, segmented detectors. In order to create images using a dose that would be acceptable for day to day patient imaging, the authors evaluated their system using the low intensity bremsstrahlung component of a 6 MeV electron beam. The system was evaluated for its uniformity, high contrast resolution, low contrast detectability, signal to noise ratio, contrast to noise ratio, and CT number linearity. Results: The prototype system was found to have a high contrast spatial resolution of about 5 line pairs per cm, and to be able to visualize a 15 mm 1.5% contrast target with 2 cGy of radiation dose delivered. SNR{sup 2} vs radiation dose and mean pixel value vs electron density curves were linear. Conclusions: This prototype system shows a large improvement in low contrast detectability over current MVCBCT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anharmonicity and mode-mode coupling effects analyzed by four-wave-mixing photon-echo spectroscopy

The present work is devoted to the description of a nonperturbative treatment of anharmonic effect and mode-mode coupling taking place in molecular vibrational systems. The information is obtained from the four-wave-mixing signal detected in the usual photon-echo phase-matched direction, termed 4WM photon-echo, using heterodyne detection to test separately the real and the imaginary parts of the third-order polarization. This approach allows a complete redistribution of the relaxation, dephasing, and transition constants on account of the magnitude of the coupling strength. In addition, our analytical approach accounts for the contributions provided by the various possible chronological orderings of the field interactions. The high sensitivity of the signal with both the energy shifts induced by the internal couplings and off-resonant energy parameter of the laser excitation is properly analyzed in the framework of our analytical description.

74 ATOMIC AND MOLECULAR PHYSICS↗

Possible radio emission from Uranus at 0.5 MHz

Radio emission from the direction of Uranus was detected in data from the radio astronomy experiment on the IMP-6 spacecraft. Previously, emission from the direction of Jupiter and Saturn was observed by the IMP-6 at a number of frequencies near 1 MHz during the period April 1971 to October 1972. These radio bursts were identified in the IMP-6 data through an analysis of the phase of the observed modulated signal detected from the spinning dipole antenna. This technique was applied to the direction of the planet Uranus with possible positive results. Over the approximately 500 days of data, three to six bursts with unique spectral characteristics were found. Identification with Uranus is confused by the likely presence of low level terrestrial and solar emission. The observed events persisted less than three minutes and are strongest in intensity near 0.5 MHz.

Brown, L. W.↗

The Alpenglow Instruments All Phase Water Probe: SBIR Phase I Final Report

Current approaches for measuring water vapor, ice water content, and liquid water content in the atmosphere have a variety of limitations. This is particularly true for ice water content measurements, which are needed in a variety of contexts including understanding the impact of clouds on global climate. The Alpenglow All-Phase Water Probe, which was motivated by limitations of current approaches to measuring water vapor, liquid water, and ice water content in the atmosphere, uses Raman scattering to derive these quantities. The use of Raman scattering signals for retrieval of water vapor mixing ratio, liquid and ice water content has been used in remote sensing applications. This project explored the use of the same approach in an in situ probe to measure all three phases of water in the atmosphere. The prototype device developed in this Phase 1 DOE SBIR proposal was used to demonstrate proof of concept for using Raman scattering to detect signals from water vapor, liquid water, and ice water. The prototype instrument consisted of the transmitting laser (355 nm, 7ns pulse), collector optics and receiver body, and data system. The receiver section body split the return signal into four channels, one for nitrogen plus channels dominated by water vapor, liquid water, and ice. Tests were conducted over a range of conditions ranging from ambient conditions in the lab (low water vapor mixing ratio, no liquid or ice water content), through a cool but saturated plume produced by an off-the-shelf humidifier (moderate water vapor mixing ratio plus some liquid water content), and hot, saturated stream containing extremely high water vapor mixing ratios with liquid water. Data from these tests, which was recorded using a Licel photon-counting data system, demonstrated the sensitivity of the system to varying water vapor mixing ratios ranging from ~5 g m -3 to > 20 g m -3 . Signals in the water vapor and ice channels were observed during the humidifier and hot vapor tests, as expected given the overlap between the ice and water vapor Raman spectra, with the relative contributions to each channel varying as expected with temperature.

58 GEOSCIENCES↗

Acoustic space occupancy: Combining ecoacoustics and lidar to model biodiversity variation and detection bias across heterogeneous landscapes

There is global interest in quantifying changing biodiversity in human-modified landscapes. Ecoacoustics may offer a promising pathway for supporting multi-taxa monitoring, but its scalability has been hampered by the sonic complexity of biodiverse ecosystems and the imperfect detectability of animal-generated sounds. The acoustic signature of a habitat, or soundscape, contains information about multiple taxa and may circumvent species identification, but robust statistical technology for characterizing community-level attributes is lacking. Here, we present the Acoustic Space Occupancy Model, a flexible hierarchical framework designed to account for detection artifacts from acoustic surveys in order to model biologically relevant variation in acoustic space use among community assemblages. We illustrate its utility in a biologically and structurally diverse Amazon frontier forest landscape, a valuable test case for modeling biodiversity variation and acoustic attenuation from vegetation density. We use complementary airborne lidar data to capture aspects of 3D forest structure hypothesized to influence community composition and acoustic signal detection. Our novel analytic framework permitted us to model both the assembly and detectability of soundscapes using lidar-derived estimates of forest structure. Our empirical predictions were consistent with physical models of frequency-dependent attenuation, and we estimated that the probability of observing animal activity in the frequency channel most vulnerable to acoustic attenuation varied by over 60%, depending on vegetation density. There were also large differences in the biotic use of acoustic space predicted for intact and degraded forest habitats, with notable differences in the soundscape channels predominantly occupied by insects. This study advances the utility of ecoacoustics by providing a robust modeling framework for addressing detection bias from remote audio surveys while preserving the rich dimensionality of soundscape data, which may be critical for inferring biological patterns pertinent to multiple taxonomic groups in the tropics. Our methodology paves the way for greater integration of remotely sensed observations with high-throughput biodiversity data to help bring routine, multi-taxa monitoring to scale in dynamic and diverse landscapes.

Airborne lidar↗