Search NASA⌕ Search

SEARCH · Search NASA

Results for “Systematic Error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

THE EFFECT OF STARSPOTS ON ACCURATE RADIUS DETERMINATION OF THE LOW-MASS DOUBLE-LINED ECLIPSING BINARY GU Boo

GU Boo is one of only a relatively small number of well-studied double-lined eclipsing binaries that contain low-mass stars. Lopez-Morales and Ribas present a comprehensive analysis of multi-color light and radial velocity curves for this system. The GU Boo light curves presented by Lopez-Morales and Ribas had substantial asymmetries, which were attributed to large spots. In spite of the asymmetry, Lopez-Morales and Ribas derived masses and radii accurate to {approx_equal}2%. We obtained additional photometry of GU Boo using both a CCD and a single-channel photometer and modeled the light curves with the ELC software to determine if the large spots in the light curves give rise to systematic errors at the few percent level. We also modeled the original light curves from the work of Lopez-Morales and Ribas using models with and without spots. We derived a radius of the primary of 0.6329 +- 0.0026 R{sub sun}, 0.6413 +- 0.0049 R{sub sun}, and 0.6373 +- 0.0029 R{sub sun} from the CCD, photoelectric, and Lopez-Morales and Ribas data, respectively. Each of these measurements agrees with the value reported by Lopez-Morales and Ribas (R{sub 1} = 0.623 +- 0.016 R{sub sun}) at the level of {approx}2%. In addition, the spread in these values is {approx}1%-2% from the mean. For the secondary, we derive radii of 0.6074 +- 0.0035 R{sub sun}, 0.5944 +- 0.0069 R{sub sun}, and 0.5976 +- 0.0059 R{sub sun} from the three respective data sets. The Lopez-Morales and Ribas value is R{sub 2} = 0.620 +- 0.020 R{sub sun}, which is {approx}2%-3% larger than each of the three values we found. The spread in these values is {approx}2% from the mean. The systematic difference between our three determinations of the secondary radius and that of Lopez-Morales and Ribas might be attributed to differences in the modeling process and codes used. Our own fits suggest that, for GU Boo at least, using accurate spot modeling of a single set of multi-color light curves results in radii determinations accurate at the {approx}2% level.

79 ASTRONOMY AND ASTROPHYSICS↗

A Hard Look at the Neutron Stars and Accretion Disks in 4U 1636-53, GX 17+2, and 4U 1705-44 with NuStar

We present NuSTAR observations of neutron star (NS) low-mass X-ray binaries: 4U 1636-53, GX 17+2, and 4U 1705-44. We observed 4U 1636-53 in the hard state, with an Eddington fraction, F{sub Edd}, of 0.01; GX 17+2 and 4U 1705-44 were in the soft state with fractions of 0.57 and 0.10, respectively. Each spectrum shows evidence for a relativistically broadened Fe K{sub α} line. Through accretion disk reflection modeling, we constrain the radius of the inner disk in 4U 1636-53 to be R{sub in}=1.03±0.03 ISCO (innermost stable circular orbit), assuming a dimensionless spin parameter a{sub ∗}=cJ/GM{sup 2}=0.0, and R{sub in}=1.08±0.06 ISCO for a{sub ∗}=0.3 (errors quoted at 1σ). This value proves to be model independent. For a{sub ∗}=0.3 and M=1.4 M{sub ⊙}, for example, 1.08 ± 0.06 ISCO translates to a physical radius of R=10.8±0.6 km, and the NS would have to be smaller than this radius (other outcomes are possible for allowed spin parameters and masses). For GX 17+2, R{sub in}=1.00--1.04 ISCO for a{sub ∗}=0.0 and R{sub in}=1.03--1.30 ISCO for a{sub ∗}=0.3. For a{sub ∗}=0.3 and M=1.4 M{sub ⊙}, R{sub in}=1.03--1.30 ISCO translates to R=10.3--13.0 km. The inner accretion disk in 4U 1705-44 may be truncated just above the stellar surface, perhaps by a boundary layer or magnetosphere; reflection models give a radius of 1.46–1.64 ISCO for a{sub ∗}=0.0 and 1.69–1.93 ISCO for a{sub ∗}=0.3. We discuss the implications our results may have on the equation of state of ultradense, cold matter and our understanding of the innermost accretion flow onto NSs with low surface magnetic fields, and systematic errors related to the reflection models and spacetime metric around less idealized NSs.

79 ASTRONOMY AND ASTROPHYSICS↗

Validation of a new control system for Elekta accelerators facilitating continuously variable dose rate

Purpose: Elekta accelerators controlled by the current clinically used accelerator control system, Desktop 7.01 (D7), uses binned variable dose rate (BVDR) for volumetric modulated arc therapy (VMAT). The next version of the treatment control system (Integrity) supports continuously variable dose rate (CVDR) as well as BVDR. Using CVDR opposed to BVDR for VMAT has the potential of reducing the treatment time but may lead to lower dosimetric accuracy due to faster moving accelerator parts. Using D7 and a test version of Integrity, differences in ability to control the accelerator, treatment efficiency, and dosimetric accuracy between the two systems were investigated. Methods: Single parameter tests were designed to expose differences in the way the two systems control the movements of the accelerator. In these tests, either the jaws, multi leaf collimators (MLCs), or gantry moved at constant speed while the dose rate was changed in discrete steps. The positional errors of the moving component and dose rate were recorded using the control systems with a sampling frequency of 4 Hz. The clinical applicability of Integrity was tested using 15 clinically used VMAT plans (5 prostate, 5 H and N, and 5 lung) generated by the SmartArc algorithm in PINNACLE. The treatment time was measured from beam-on to beam-off and the accuracy of the dose delivery was assessed by comparing DELTA4 measurements and PINNACLE calculated doses using gamma evaluation. Results: The single parameter tests showed that Integrity had an improved feedback between gantry motion and dose rate at the slight expense of MLC control compared to D7. The single parameter test did not reveal any significant differences in the control of either jaws or backup jaws between the two systems. These differences in gantry and MLC control together with the use of CVDR gives a smoother Integrity VMAT delivery compared to D7 with less abrupt changes in accelerator motion. Gamma evaluation (2% of 2 Gy and 2 mm) of the calculated doses and DELTA4 measured doses corrected for systematic errors showed an average pass rate of more than 97.8% for both D7, Integrity BVDR, and Integrity CVDR deliveries. Direct comparisons between the measured doses using strict gamma criteria of 0.5% and 0.5 mm showed excellent agreement between D7 and Integrity delivered doses with average pass rates above 95.7%. Finally, the Integrity control system resulted in a significant 35% (55 {+-} 13 s) reduction in treatment time, on average. Conclusions: Single parameter tests showed that the two control systems differed in their feedback loops between MLC, gantry, and dose rate. These differences made the VMAT deliveries more smooth using the new Integrity treatment control system, compared to the current Desktop 7.01. Together with the use of CVDR, which results in less abrupt changes in dose rate, this further increases the smoothness of the delivery. The use of CVDR for VMAT with the Integrity desktop results in a significant reduction in treatment time compared to BVDR with an average reduction of 35%. This decrease in delivery time was achieved without compromising the dosimetric accuracy.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-642: Safety Procedures for Error Elimination in Cyberknife Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT)

Purpose: Cyberknife system is used for providing stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) hypofractionation scheme. The whole treatment delivery is based on live imaging of the patient. The minor error made at any stage may bring severe radiation injury to the patient or damage to the system itself. Several safety measures were taken to make the system safer. Methods: The radiation treatment provided thru a 6MV linac attached to Kuka robot (Cyberknife G4, Accuray Inc. Sunnyvale, CA, USA). Several possible errors were identified related to patient alignment, treatment planning, dose delivery and physics quality assurance. During dose delivery, manual and visual checks were introduced to confirm pre and intra-treatment imaging to reduce possible errors. One additional step was introduced to confirm that software tracking-tools had worked correctly with highest possible confidence level. Robotic head move in different orientations over and around the patient body, the rigidity of linac-head cover and other accessories was checked periodically. The vender was alerted when a tiny or bigger piece of equipment needed additional interlocked support. Results: As of our experience treating 525 patients on Cyberknife during the last four years, we saw on and off technical issues. During image acquisition, it was made essential to follow the site-specific imaging protocols. Adequate anatomy was contoured to document the respective doses. Followed by auto-segmentation, manual tweaking was performed on every structure. The calculation box was enclosing the whole image during the final calculation. Every plan was evaluated on slice-by slice basis. To review the whole process, a check list was maintained during the physics 2nd-check. Conclusion: The implementation of manual and visual additional checks introduced along with automated checks for confirmation was found promising in terms of reduction in systematic errors and making the system safer than before.

60 APPLIED LIFE SCIENCES↗

Resolve survey photometry and volume-limited calibration of the photometric gas fractions technique

We present custom-processed ultraviolet, optical, and near-infrared photometry for the REsolved Spectroscopy of a Local VolumE (RESOLVE) survey, a volume-limited census of stellar, gas, and dynamical mass within two subvolumes of the nearby universe (RESOLVE-A and RESOLVE-B). RESOLVE is complete down to baryonic mass ∼10{sup 9.1−9.3} M{sub ⊙}, probing the upper end of the dwarf galaxy regime. In contrast to standard pipeline photometry (e.g., SDSS), our photometry uses optimal background subtraction, avoids suppressing color gradients, and employs multiple flux extrapolation routines to estimate systematic errors. With these improvements, we measure brighter magnitudes, larger radii, bluer colors, and a real increase in scatter around the red sequence. Combining stellar mass estimates based on our optimized photometry with the nearly complete H i mass census for RESOLVE-A, we create new z = 0 volume-limited calibrations of the photometric gas fractions (PGF) technique, which predicts gas-to-stellar mass ratios (G/S) from galaxy colors and optional additional parameters. We analyze G/S-color residuals versus potential third parameters, finding that axial ratio is the best independent and physically meaningful third parameter. We define a “modified color” from planar fits to G/S as a function of both color and axial ratio. In the complete galaxy population, upper limits on G/S bias linear and planar fits. We therefore model the entire PGF probability density field, enabling iterative statistical modeling of upper limits and prediction of full G/S probability distributions for individual galaxies. These distributions have two-component structure in the red color regime. Finally, we use the RESOLVE-B 21 cm census to test several PGF calibrations, finding that most systematically under- or overestimate gas masses, but the full probability density method performs well.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraints on Neutrino Oscillation Parameters from Neutrinos and Antineutrinos with Machine Learning

NOvA is a two detector, long baseline neutrino oscillation experiment measuring the oscillations of muon neutrinos from the \numi neutrino beam over a baseline of \SI{810}{km}. The experiment uses four oscillation channels, $\numu \rightarrow \numu$, $\numubar \rightarrow \numubar$, $\numu \rightarrow \nue$, and $\numubar \rightarrow \nuebar$, with a peak neutrino energy of \SI{1.8}{GeV}. This dissertation describes the analysis of these channels using a dataset of $13.6\times10^{20}$ protons on target neutrino beam mode and $12.5\times10^{20}$ protons on target antineutrino beam mode. The analysis makes use of improvements in the treatment of systematic uncertainties and machine learning techniques to reconstruct neutrino interactions. A technique for decorrelating systematic errors using principle component analysis was utilized to reduce and optimize neutrino cross section and beam related uncertainties. The improved machine learning algorithms make use of convolutional ne ural net works for neutrino event classification, particle classification, and instance segmentation. The selection of neutrino signal events utilizing the neutrino event classifier shows an efficiency of 63\% for the selection of electron neutrinos in neutrino beam mode and 75\% for electron antineutrinos in antineutrino beam mode. Using this algorithm, 82 appearing electron neutrino candidates and 33 appearing electron antineutrino candidates were observed with expected backgrounds of 26.8 and 14.0 respectively. In addition, 211 surviving muon neutrino candidates and 105 muon antineutrino candidates were identified with a purity of more than 96\% using the same neutrino event classifier. Fitting these data to the three flavor neutrino oscillation model, using constraints on \thetaonetwo, \thetaonethree, and \dmsqonetwo from solar and reactor neutrino experiments, the oscillation parameters are measured to be $\sintwothree = 0.57^{+0.04}_{-0.03}$, $\dmsqthreetwo = \SI[parse-numbers= false]{+ 2.41\pm0.07 \times 10^{-3}}{eV^2}$, and $\dcp=0.82^{+0.27}_{-0.87}\pi$ with a preference for the normal neutrino mass hierarchy. Leading systematic uncertainties for these measurements come from detector calibration and neutrino interaction models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cluster cosmology without cluster finding

ABSTRACT We propose that observations of supermassive galaxies contain cosmological statistical constraining power similar to conventional cluster cosmology, and we provide promising indications that the associated systematic errors are comparably easier to control. We consider a fiducial spectroscopic and stellar mass complete sample of galaxies drawn from the Dark Energy Spectroscopic Instrument (DESI) and forecast how constraints on Ωm–σ8 from this sample will compare with those from number counts of clusters based on richness λ. At fixed number density, we find that massive galaxies offer similar constraints to galaxy clusters. However, a mass-complete galaxy sample from DESI has the potential to probe lower halo masses than standard optical cluster samples (which are typically limited to λ ≳ 20 and Mhalo ≳ 1013.5 M⊙ h−1); additionally, it is straightforward to cleanly measure projected galaxy clustering wp for such a DESI sample, which we show can substantially improve the constraining power on Ωm. We also compare the constraining power of M*-limited samples to those from larger but mass-incomplete samples [e.g. the DESI Bright Galaxy Survey (BGS) sample]; relative to a lower number density M*-limited samples, we find that a BGS-like sample improves statistical constraints by 60 per cent for Ωm and 40 per cent for σ8, but this uses small-scale information that will be harder to model for BGS. Our initial assessment of the systematics associated with supermassive galaxy cosmology yields promising results. The proposed samples have a ∼10 per cent satellite fraction, but we show that cosmological constraints may be robust to the impact of satellites. These findings motivate future work to realize the potential of supermassive galaxies to probe lower halo masses than richness-based clusters and to potentially avoid persistent systematics associated with optical cluster finding.

(cosmology): large-scale structure of Universe↗

TYPE Ia SUPERNOVA COLORS AND EJECTA VELOCITIES: HIERARCHICAL BAYESIAN REGRESSION WITH NON-GAUSSIAN DISTRIBUTIONS

We investigate the statistical dependence of the peak intrinsic colors of Type Ia supernovae (SNe Ia) on their expansion velocities at maximum light, measured from the Si II λ6355 spectral feature. We construct a new hierarchical Bayesian regression model, accounting for the random effects of intrinsic scatter, measurement error, and reddening by host galaxy dust, and implement a Gibbs sampler and deviance information criteria to estimate the correlation. The method is applied to the apparent colors from BVRI light curves and Si II velocity data for 79 nearby SNe Ia. The apparent color distributions of high-velocity (HV) and normal velocity (NV) supernovae exhibit significant discrepancies for B – V and B – R, but not other colors. Hence, they are likely due to intrinsic color differences originating in the B band, rather than dust reddening. The mean intrinsic B – V and B – R color differences between HV and NV groups are 0.06 ± 0.02 and 0.09 ± 0.02 mag, respectively. A linear model finds significant slopes of –0.021 ± 0.006 and –0.030 ± 0.009 mag (10{sup 3} km s{sup –1}){sup –1} for intrinsic B – V and B – R colors versus velocity, respectively. Because the ejecta velocity distribution is skewed toward high velocities, these effects imply non-Gaussian intrinsic color distributions with skewness up to +0.3. Accounting for the intrinsic-color-velocity correlation results in corrections to A{sub V} extinction estimates as large as –0.12 mag for HV SNe Ia and +0.06 mag for NV events. Velocity measurements from SN Ia spectra have the potential to diminish systematic errors from the confounding of intrinsic colors and dust reddening affecting supernova distances.

79 ASTRONOMY AND ASTROPHYSICS↗

MODEL AND ALGORITHM EVALUATION FOR THE HYBRID UF6 CONTAINER INSPECTION SYSTEM

ABSTRACT Pacific Northwest National Laboratory (PNNL) is developing an automated UF6 cylinder verification station concept based on the combined collection of traditional enrichment-meter (186 keV photons from U-235) data and non-traditional, neutron-induced, high-energy gamma-signatures (3-8.5 MeV) with an array of collimated, medium-resolution scintillators. Previous (2010) work at PNNL demonstrated proof-of-principle that this hybrid method yields accurate, full-volume assay of the cylinder enrichment, reduces systematic errors when compared to several other enrichment assay methods, and provides simplified instrumentation and algorithms suitable for long-term unattended operations. We used Monte Carlo modeling with MCNP5 to support system design (e.g., number and configuration of detector arrays, and design of iron/poly collimators for enhanced (n,γ) conversion) and enrichment algorithm development. We developed a first-generation modeling framework in 2010. These tools have since been expanded, refined and benchmarked against field measurements with a prototype system of a 30B cylinder population (0.2 to 4.95 weight % U-235). The MCNP5 model decomposes the radiation transport problem into a linear superposition of “basis spectra” representing contributions from the different uranium isotopes and gamma-ray generation mechanisms (e.g. neutron capture). This scheme accommodates fast generation of “virtual assay signatures” for arbitrary enrichment, material age, and fill variations. Ongoing (FY-2011) refinements to the physics model include accounting for generation of bremsstrahlung photons, arising primarily from the beta decay of Pa-234m, a U-238 daughter. We are using the refined model to optimize collimator design for the hybrid method. The traditional assay method benefits from a high degree of collimation (to isolate each detector’s field-of-view) and relatively small detector area, while the non-traditional method benefits from a wide field-of-view, i.e. less collimation and larger detectors. We implement the enrichment-meter method by applying a square-wave digital filter to a raw spectrum and extracting the 186-keV peak area directly from the convolute spectrum. Ongoing enhancements to this approach include mitigating a systematic peak-area measurement deficit arising from curvature in the spectrum continuum shape. An optimized system prototype based on model results is utilized in a new set of 2011 field measurements, and model and measurement enrichment assay uncertainties are compared.

MODEL AND ALGORITHM EVALUATION FOR THE HYBRID UF6 ↗

Lattice QCD Calculation of Nucleon Structure

It is emphasized in the 2015 NSAC Long Range Plan that "understanding the structure of hadrons in terms of QCD's quarks and gluons is one of the central goals of modern nuclear physics." Over the last three decades, lattice QCD has developed into a powerful tool for ab initio calculations of strong-interaction physics. Up until now, it is the only theoretical approach to solving QCD with controlled statistical and systematic errors. Since 1985, we have proposed and carried out first-principles calculations of nucleon structure and hadron spectroscopy using lattice QCD which entails both algorithmic development and large-scale computer simulation. We started out by calculating the nucleon form factors -- electromagnetic, axial-vector, πNN, and scalar form factors, the quark spin contribution to the proton spin, the strangeness magnetic moment, the quark orbital angular momentum, the quark momentum fraction, and the quark and glue decomposition of the proton momentum and angular momentum. The first round of calculations were done with Wilson fermions in the `quenched' approximation where the dynamical effects of the quarks in the sea are not taken into account in the Monte Carlo simulation to generate the background gauge configurations. Beginning in 2000, we have started implementing the overlap fermion formulation into the spectroscopy and structure calculations. This is mainly because the overlap fermion honors chiral symmetry as in the continuum. It is going to be more and more important to take the symmetry into account as the simulations move closer to the physical point where the u and d quark masses are as light as a few MeV only. We began with lattices which have quark masses in the sea corresponding to a pion mass at ~ 300 MeV and obtained the strange form factors, charm and strange quark masses, the charmonium spectrum and the D s meson decay constant f D s , the strangeness and charmness, the meson mass decomposition and the strange quark spin from the anomalous Ward identity. Recently, we have started to include multiple lattices with different lattice spacings and different volumes including large lattices at the physical pion mass point. We are getting quite close to being able to calculate the hadron structure at the physical point and to do the continuum and large volume extrapolations, which is our ultimate aim. We have now finished several projects which have included these systematic corrections. They include the leptonic decay width of the ρ, the πN sigma and strange sigma terms, and the strange quark magnetic moment. Over the years, we have also studied hadron spectroscopy with lattice calculations and in phenomenology. These include Roper resonance, pentaquark state, charmonium spectrum, glueballs, scalar mesons a 0 (1450) and σ(600) and other scalar mesons, and the 1 -+ meson. In addition, we have employed the canonical approach to explore the first-order phase transition and the critical point at finite density and finite temperature. We have also discovered a new parton degree of freedom -- the connected sea partons, from the path-integral formulation of the hadronic tensor, which explains the experimentally observed Gottfried sum rule violation. Combining experimental result on the strange parton distribution, the CT10 global fitting results of the total u and d anti-partons and the lattice result of the ratio of the momentum fraction of the strange vs that of u or d in the disconnected insertion, we have shown that the connected sea partons can be isolated. In this final technical report, we shall present a few representative highlights that have been achieved in the project.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Kiloampere, Variable-Temperature, Critical-Current Measurements of High-Field Superconductors

We review variable-temperature, transport critical-current ($I_\text{c}$) measurements made on commercial superconductors over a range of critical currents from less than 0.1 A to about 1 kA. We have developed and used a number of systems to make these measurements over the last 15 years. Two exemplary variable-temperature systems with coil sample geometries will be described: a probe that is only variable-temperature and a probe that is variable-temperature and variable-strain. The most significant challenge for these measurements is temperature stability, since large amounts of heat can be generated by the flow of high current through the resistive sample fixture. Therefore, a significant portion of this review is focused on the reduction of temperature errors to less than ±0.05 K in such measurements. A key feature of our system is a pre-regulator that converts a flow of liquid helium to gas and heats the gas to a temperature close to the target sample temperature. The pre-regulator is not in close proximity to the sample and it is controlled independently of the sample temperature. This allows us to independently control the total cooling power, and thereby fine tune the sample cooling power at any sample temperature. The same general temperature-control philosophy is used in all of our variable temperature systems, but the addition of another variable, such as strain, forces compromises in design and results in some differences in operation and protocol. These aspects are analyzed to assess the extent to which the protocols for our systems might be generalized to other systems at other laboratories. Our approach to variable-temperature measurements is also placed in the general context of measurement-system design, and the perceived advantages and disadvantages of design choices are presented. To verify the accuracy of the variable-temperature measurements, we compared critical-current values obtained on a specimen immersed in liquid helium (“liquid” or $I_{\text{c}}$ $_{\text{liq}}$) at 5 K to those measured on the same specimen in flowing helium gas (“gas” or Ic gas) at the same temperature. These comparisons indicate the temperature control is effective over the superconducting wire length between the voltage taps, and this condition is valid for all types of sample investigated, including Nb-Ti, Nb 3 Sn, and MgB 2 wires. The liquid/gas comparisons are used to study the variable-temperature measurement protocol that was necessary to obtain the “correct” critical current, which was assumed to be the $I_{\text{c}}$ $_{\text{liq}}$. We also calibrated the magnetoresistance effect of resistive thermometers for temperatures from 4 K to 35 K and magnetic fields from 0 T to 16 T. This calibration reduces systematic errors in the variable-temperature data, but it does not affect the liquid/gas comparison since the same thermometers are used in both cases.

47 OTHER INSTRUMENTATION↗

Global patterns and controls of soil organic carbon dynamics as simulated by multiple terrestrial biosphere models. Current status and future directions

Soil is the largest organic carbon (C) pool of terrestrial ecosystems, and loss from soil accounts for a large pro portion of land-atmosphere C exchange. Due to large pool size and variable residence time from years to millennia, even small changes in soil organic C(SOC) have substantial effects on the terrestrial C budget, thereby affecting atmospheric carbon dioxide (CO2)concentration and climate change. In the past decades, a wide variety of studies have been conducted to quantify global SOC stocks and soil exchange with the atmosphere through site measurements, inventories, and empirical/process-based modeling. However, these estimates are highly uncertain and identifying major driving forces controlling soil C storage and fluxes remains a key research challenge his study has compiled century-long (1901-2010)estimates of SOC storage and heterotrophic respiration (Rh) from ten terrestrial biosphere models (TBMs) in the Multi-scale Synthesis and Terrestrial Model Intercomparison Project (MsTMIP) and two observation based datasets. The ten-TBM ensemble shows that global SOC estimate range from 4 to 2111 Pg C (1 Pg = 10 15 g) with a median value of 1158 Pg C33 in 2010. Modeling approach estimates a broad range of Rh from 35 to 69 Pg C yr -1 with a median value of 51Pg C yr -1 during 200–2010. The largest uncertainty in SOC stocks exists in the 40–65°N latitude band while Rh differences are the largest in the tropics. All the models agreed that climate and land use changes have decreased SOC stocks while elevated CO 2 and atmospheric nitrogen deposition have increased SOC stocks though the response varied significantly among models. Model representations of temperature and moisture sensitivity,nutrient limitation and land use partially explain the divergent estimates of global SOC stocks and soil fluxes in this study. In addition, major sources of uncertainty from model estimation include exclusion of SOC storage in wetlands and peatlands as well as C storage in deep soil layers.

54 ENVIRONMENTAL SCIENCES↗

CMIP5 multi-model hindcasts for the mid-1970s shift and early 2000s hiatus and predictions for 2016-2035: Meehl and Teng: Initialized hindcasts and predictions

Compared to uninitialized climate change projections, a multi-model ensemble from the CMIP5 10 year decadal prediction experiments produces more warming during the mid-1970s climate shift and less warming in the early 2000s hiatus in both the tropical Indo-Pacific region and globally averaged surface air temperature (TAS) in closer agreement with observations. Assuming bias in TAS has stabilized in the 10 year predictions, after bias adjustment, TAS anomalies for the 2016–2035 period in the 30 year predictions initialized in 2006 are about 16% less than the uninitialized projections. One contributing factor for the improved climate simulation is the bias adjustment, which corrects the models’ systematic errors and higher-than-observed decadal warming trend. Another important factor is the initialization with observations which constrains the ocean such that the starting points of the initialized simulations are close to the observed initial states.

54 ENVIRONMENTAL SCIENCES↗

Trends and sensitivities of low streamflow extremes to discharge timing and magnitude in Pacific Northwest mountain streams

Abstract Path analyses of historical streamflow data from the Pacific Northwest indicate that the precipitation amount has been the dominant control on the magnitude of low streamflow extremes compared to the air temperature‐affected timing of snowmelt runoff. The relative sensitivities of low streamflow to precipitation and temperature changes have important implications for adaptation planning because global circulation models produce relatively robust estimates of air temperature changes but have large uncertainties in projected precipitation amounts in the Pacific Northwest U.S. Quantile regression analyses indicate that low streamflow extremes from the majority of catchments in this study have declined from 1948 to 2013, which may significantly affect terrestrial and aquatic ecosystems, and water resource management. Trends in the 25th percentile of mean annual streamflow have declined and the center of timing has occurred earlier. We quantify the relative influences of total precipitation and air temperature on the annual low streamflow extremes from 42 stream gauges using mean annual streamflow as a proxy for precipitation amount effects and streamflow center of timing as a proxy for temperature effects on low flow metrics, including 7q10 summer (the minimum 7 day flow during summer with a 10 year return period), mean August , mean September , mean summer , 7q10 winter , and mean winter flow metrics. These methods have the benefit of using only readily available streamflow data, which makes our results robust against systematic errors in high elevation distributed precipitation data. Winter low flow metrics are weakly tied to both mean annual streamflow and center of timing .

Kormos, Patrick R.↗

Evidence of Free-Bound Transitions in Warm Dense Matter and Their Impact on Equation-of-State Measurements

Warm dense matter (WDM) is now routinely created and probed in laboratories around the world, providing unprecedented insights into conditions achieved in stellar atmospheres, planetary interiors, and inertial confinement fusion experiments. However, the interpretation of these experiments is often filtered through models with systematic errors that are difficult to quantify. Due to the simultaneous presence of quantum degeneracy and thermal excitation, transitions in which free electrons are de-excited into thermally unoccupied bound states transferring momentum and energy to a scattered x-ray photon become viable. Here we show that such free-bound transitions are a particular feature of WDM and vanish in the limits of cold and hot temperatures. The inclusion of these transitions into the analysis of recent X-ray Thomson Scattering experiments on WDM at the National Ignition Facility and the Linac Coherent Light Source is required to obtain a physically consistent temperature from the Chihara decomposition. This interpretation is corroborated by agreement with a recently developed model-free thermometry technique and presents an important step for precisely characterizing and understanding the complex WDM state of matter.

Boehme, M [HZDR Dresden]↗

Evaluation of energy balance closure adjustment methods by independent evapotranspiration estimates from lysimeters and hydrological simulations

Here, we report non-closure of the surface energy balance is a frequently observed phenomenon of hydrometeorological field measurements, when using the eddy-covariance method, which can be ascribed to an underestimation of the turbulent fluxes. Several approaches have been proposed in order to adjust the measured fluxes for this apparent systematic error. However, there are uncertainties about partitioning of the energy balance residual between the sensible and latent heat flux and whether such a correction should be applied on 30-minute data or longer time scales. The data for this study originate from two grassland sites in southern Germany, where measurements from weighable lysimeters are available as reference. The adjusted evapotranspiration rates are also compared with joint energy and water balance simulations using a physically-based distributed hydrological model. We evaluate two adjustment methods: the first one preserves the Bowen ratio and the correction factor is determined on a daily basis. The second one attributes a smaller portion of the residual energy to the latent heat flux than to the sensible heat flux for closing the energy balance for every 30-minute flux integration interval. Both methods lead to an improved agreement of the eddy-covariance based fluxes with the independent lysimeter estimates and the physically-based model simulations. The first method results in a better comparability of evapotranspiration rates, and the second method leads to a smaller overall bias. These results are similar between both sites despite considerable differences in terrain complexity and grassland management. Moreover, we found that a daily adjustment factor leads to less scatter than a complete partitioning of the residual for every half-hour time interval. Lastly, the vertical temperature gradient in the surface layer and friction velocity were identified as important predictors for a potential future parameterization of the energy balance residual.

58 GEOSCIENCES↗

Nonperturbative β function of twelve-flavor SU(3) gauge theory

We study the discrete β function of SU(3) gauge theory with N f = 12 massless fermions in the fundamental representation. Using an nHYP-smeared staggered lattice action and an improved gradient flow running coupling g &#x007E;<!-- ~ --> c 2 ( L ) we determine the continuum-extrapolated discrete β function up to g c 2 ≈ 8.2. We observe an IR fixed point at g * 2 = 7.3( -2 + 8 ) in the c = 8 t / L = 0.25 scheme, and g * 2 = 7.3( -3 + 6 ) with c = 0.3, combining statistical and systematic uncertainties in quadrature. The systematic effects we investigate include the stability of the (a/L) → 0 extrapolations, the interpolation of g &#x007E;<!-- ~ --> c 2 ( L ) as a function of the bare coupling, the improvement of the gradient flow running coupling, and the discretization of the energy density. In an appendix we observe that the resulting systematic errors increase dramatically upon combining smaller c ≲ 0.2 with smaller L ≤ 12, leading to an IR fixed point at g * 2 = 5.9(1.9) in the c = 0.2 scheme, which resolves to g * 2 = 6.9( -1 + 6 ) upon considering only L ≥ 16. At the IR fixed point we measure the leading irrelevant critical exponent to be γ g * = 0.26(2), comparable to perturbative estimates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bottomonium suppression and elliptic flow using Heavy Quarkonium Quantum Dynamics

We introduce a framework called Heavy Quarkonium Quantum Dynamics (HQQD) which can be used to compute the dynamical suppression of heavy quarkonia propagating in the quark-gluon plasma using real-time in-medium quantum evolution. Using HQQD we compute large sets of real-time solutions to the Schrödinger equation using a realistic in-medium complex-valued potential. We sample 2 million quarkonia wave packet trajectories and evolve them through the QGP using HQQD to obtain their survival probabilities. The computation is performed using three different HQQD model parameter sets in order to estimate our systematic uncertainty. After taking into account final state feed down we compare our results to existing experimental data for the suppression and elliptic flow of bottomonium states and find that HQQD predictions are good agreement with available data for R AA as a function of N part and p T collected at \( \sqrt{s_{\mathrm{NN}}} \) = 5 . 02 TeV. In the case of v 2 for the various states, we find that the path-length dependence of ϒ(1 s ) suppression results in quite small v 2 for ϒ(1 s ). Our prediction for the integrated elliptic flow for ϒ(1 s ) in the 10 – 90% centrality class, which now includes an estimate of the systematic error, is v 2 [ϒ(1 s )] = 0 . 003 ± 0 . 0007 ± \( {}_{0.0013}^{0.0006} \) . We also find that, due to their increased suppression, excited bottomonium states have a larger elliptic flow. Based on this observation we make predictions for v 2 [ϒ(2 s )] and v 2 [ϒ(3 s )] as a function of centrality and transverse momentum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗