Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing Procedure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

The Effects of Absorber Thickness on Reverse-Bias Damage in Cu(In,Ga)Se2 Solar Cells

We studied a variety of absorber thicknesses in Cu(In,Ga)Se 2 devices to examine the ability of the cell to withstand reverse current flow without damage. Absorbers were varied from 2.5 um to 0.4 um, with the expectation that larger reverse current would be allowed to flow at lower voltages as absorbers were made thinner. Our initial experiments showed promise. However, as the efficiency of thin devices was improved, the reverse current allowed at a given voltage decreased. Here we present our negative results on the ability of thin devices to allow higher reverse currents at lower voltages. We also give details on our procedures for reverse-bias testing small-area solar cells. We hope this information will be useful for those who want to study reverse-bias at the cell level.

14 SOLAR ENERGY↗

The Design, Construction and Testing of the Straw Tracking Detectors for the E989 Muon g-2 Experiment at Fermilab.

The requirement of science, to stretch the boundaries and our understanding of the standard model,is the driving force for the continuous development of our knowledge of the building blocks of theUniverse. Experiments are designed, built and tested to support the theories of the mathematiciansof the physics community and the theorists help interpret the experimental results, looking foravenues of new physics. However, as is known in both science and human nature, nothing is everperfect - there is always room for improvement.The E989 Muon g-2 Collaboration experiment at Fermi National Accelerator Laboratory (otherwiseknown as Fermilab), aims to quantify the muon anomalous magnetic moment to unprecedentedprecision and looks to increase the accuracy of the measurement by fourfold of the predecessorexperiment - E821 at Brookhaven. The discrepancy between the theoretical prediction of theanomalous magnetic moment of the muon and the experimental results, has given tantalisingindication of new physics, prompting an ”upgrade” for systematic accuracy on the E821.The particular focus of this thesis details the design, construction and quality testing of the strawtracking modules for the E989 experiment. The author was one of the dedicated technicians whobuilt and tested the tracker modules at the University of Liverpool High Energy Physics (HEP)department, she built and quality tested the modules, wrote the procedural document for the buildand subsequently was involved in the Run I startup, shut down and data taking shifts (for Run Iand Run II) which contributed to the recent release of the first unblinded data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Secondary Containment Design for the LLNL B801 Diala Oil Tank

Design is to add an extension to the secondary containment of tank T1-A3 at building 801. Piping from the inner tank penetrates the secondary containment tank below the liquid level of the primary tank. To meet Oil Pollution Prevention Regulation 40 CFR 120.7 the single wall piping needs to be provided with secondary containment. Steel Tank Institute (STI) conference publication states: §112.3(d)(1)(iii) –SPCC Plan requirements- Systems shall be designed in accordance with good engineering practice, including consideration of applicable industry standards and that procedures for required inspections and testing have been established. Section 112.7(a)(2) allows for deviations from specific rule requirements, provided the Owner/operator responsible to select, document and implement alternate measure and a PE certifies the SPCC Plan in accordance with good engineering practices, including consideration of industry standards

42 ENGINEERING↗

Minimize Solvent Oxidation with NO X Pre-Scrubbing

A novel method to remove nitrogen dioxide (NO 2 ) from the flue gas of coal-fired power plants with CO 2 capture was further developed for commercial implementation. The technology leverages the equipment and chemistry in an existing (sulfur dioxide) SO 2 polishing scrubber upstream of the main CO 2 capture unit to remove the NO 2 , preventing degradation of the CO 2 capture solvent and formation of nitrosamines (environmental hazards). The research in this report focuses on further evaluation of the chemical additives and operating conditions associated with the NO 2 removal process to define conditions for commercial scale testing and deployment. Experimental work systematically evaluated a series of potential additives to minimize the oxidation of sulfite in a representative SO 2 pre-scrubber solution (sulfite, in turn, absorbs NO 2 ). The additive combinations and concentrations were varied alongside important process conditions such as temperature, oxygen concentration, and metals present in solution to mimic the conditions expected in a commercial system. Important results of the parametric experimental work include identifying a new, potent sulfite oxidation inhibitor, revealing the importance of combining inhibitors with metal chelating agents, validation of a low-cost additive process, and development of a new semi-empirical model to represent mechanisms associated with sulfite oxidation. In addition, the experimental work reveled the impact of operating at higher temperatures (representative of a field test unit), which will guide the selection and concertation of additives as well. Engineering analysis found that waste solutions from the pre-scrubber with NO 2 additives may potentially be integrated with existing processes on site (e.g., flue gas desulfurization unit). In addition, techno-economic analysis identified potential net savings as large as $1.30/tonne CO 2 captured and quantified the potential benefit of low cost additive options actively being pursued by the development team. Finally, the experimental results and engineering analysis supported the development of a detailed field testing plan and protocol to evaluate the technology at near-commercial scale. The field test preparation included development of procedures to introduce chemical additives to an existing SO 2 polishing unit and identification of representative flue gas conditions based on a review of existing plants. These activities will have direct bearing on operation and design of commercial units.

20 FOSSIL-FUELED POWER PLANTS↗

Utilizing Commercial Real Estate Owner and Investor Data to Analyze the Financial Performance of Energy Efficient, High-Performance Office Buildings

Evidence has shown that owning and operating energy-efficient, high-performance, “green” properties results in multiple benefits including lower utility bills, higher rents, improved occupancy, and greater net operating income. However, it is difficult to isolate and control moderating factors to identify the specific drivers behind improved financial performance and value to investors that results from sustainability in real estate. DOE is interested in facilitating deeper investigation of the correlation between energy efficiency and financial performance, reducing data acquisition and matching challenges, and developing a stronger understanding of how sustainable design and energy efficiency impact value. DOE commissioned this pilot study to test the logistical and empirical procedures required to establish a Commercial Real Estate Data Aggregation & Trends Analysis lab, determine the potential benefits available through the lab, and contribute to the existing body of evidence in this field.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hardness Prediction by Incorporating Heat Transfer and Molten Pool Fluid Flow in a Multi-pass, Multi-layer Weld for Onsite Repair of Grade 91 steel

Introduction: In the current fleet of fossil-fired power plants, creep strength enhanced ferritic steels (CSEF) are used to sustain the harsh service conditions. Enhanced properties of Grade 91 steel result from tempered martensite with a fine distribution of MX and M23C6 carbides. Grade 91 steel is subjected to onsite welding repair to remedy their degradation due to extreme service condition. Knowledge of weld repairability of these steels, such as as-welded hardness distribution, is essential to establishing sound repair procedures. Experimental trial and error tests can consume a lot of time as many welding variables need to be studied. For numerical modelling, most of the multi-pass multi-layer models are based on finite element method, which are limited to solve the heat conduction equation and ignore convective heat transfer due to melt flow. Moreover, the mesh has to be pre-built based on a known or assumed weld cross-section geometry. These finite element based models thus have limited predictive capability as defects are not considered and nugget size are pre-assumed. This research aims at developing a thermal and microstructure evolution model incorporating molten pool dynamics in a multi-pass multi-layer material deposition to predict the as-welded hardness distribution. Technical Approach: All the thermal, physical, and metallurgical properties of Grade 91 as a function of temperature are collected from the literature and inputted into the thermo-fluid model based on Flow-3D, a computational fluid dynamics software. A multi-pass, multi-layer material deposition is simulated where the melting of filler wire into the molten pool is directly considered based on the volume of fluid (VOF) method. The flow behaviour of the molten pool is used to understand the formation of deposition geometry and defects. The temperature profiles during the multi-pass, multi-layer welding are calculated. The results computed using the new model are compared against the experimental data of fusion zone geometry and thermal cycles. Hardness prediction in the heat-affected zone (HAZ) are made using Johnson-Mehl-Avrami (JMA) equation for solid-state phase transformation kinetics. The JMA parameters are extracted from the experimental data available in the literature. For comparison, a standard finite element heat conduction model is also developed to predict the thermal cycles and hardness distribution in the multi-pass, multi-layer weld. Expected Result: Results obtained using the molten pool dynamic simulation versus the finite element heat conduction model are compared. Specifically, the effects of convective heat transfer on the accuracy of the calculated thermal history, bead shape and size, and HAZ hardness distribution are examined.

Modeling, Grade 91 steel, Multi-pass multi-layer d↗

Ensuring Workforce Readiness for the Energy Industry Through 3D Simulations

In February 2009, during his joint address to Congress, President Obama challenged every American to commit to at least one year of college education and set a goal that the United States should once again have the highest proportion of college graduates in the world by the year 2020. This push by the Obama administration reflected the understanding that while a college degree was becoming a prerequisite to obtain many of the jobs in the 21. century economy; the United States still lagged behind other countries with respect to higher education attainment. Because of this, the U.S. is facing a skills gap between the credentials required for the jobs of today and tomorrow, and the number of skilled workers eligible to fill those jobs. Within the energy industry, the skills gap is compounded by two factors: an expanding domestic industry in energy generation and transmission, and an aging workforce set to retire in large numbers. In fact, a 2013 survey administered by Center for Energy Workforce Development (CEWD) estimates that 36% of the workforce may need to be replaced in the next five years, and nearly 50% will need to be replaced by the year 2023. As a 2014 report by CEWD notes, 'The message for workforce development is clear: qualified and skilled utility technicians and engineers will continue to be in high demand in all types of energy generation, transmission, and distribution jobs'. Simulations provide students the ability to practice proper procedure in a safe environment, test out multiple scenarios to determine an optimal outcome, and repeat practice to solidify learning. Industry currently applies simulation (i.e., 3D Electrical Substation Simulation) as it affords an opportunity for technicians to train in a safe, virtual environment, thus eliminating risks associated with arc flash hazards. The intent of 3D simulation is to enhance the students' understanding of the concepts learned in the course and better prepare students for field work in a related technical discipline. The 3D simulation will reinforce the concepts learned during a specific course and are intended to add real world context to the curriculum. The 3D simulation will be designed such that a student will perform specific job activities incorporating concepts learned during the course. This method of instruction ensures students have an understanding of the concepts and are able to apply the concepts in a real world context. Different scenarios will be developed to ensure a thorough understanding of the concepts with real time feedback when there is a misunderstanding of the concepts. (authors)

97 MATHEMATICS AND COMPUTING↗

Assembly and Testing of Scintillator Tile Modules for the CMS High-Granularity Calorimeter Upgrade

The High-Granularity Calorimeter (HGCAL), part of the upgrade to the Compact Muon Solenoid (CMS) experiment, employs silicon and scintillator tile modules in the endcaps to maintain detector performance during the High-Luminosity Large Hadron Collider (HL-LHC) era, scheduled to operate from 2030 to 2040. The upgraded calorimeter will provide highly segmented three-dimensional imaging, energy measurements, and precise timing for particle shower reconstruction. Approximately half of the HGCal plastic scintillator tile modules (1,834 total) will be assembled at Fermilab using an automated pick-and-place (PnP) machine. Following assembly, each tile module undergoes quality control (QC) procedures such as electrical validation, thermal testing, and physics validation using cosmic rays. This poster/talk presents the QC procedures and results from the tile module production in 2026, demonstrating the performance and quality of the assembled tile modules.

Bazimya, Jean Luc [Grambling State U.]↗

Planning Roadmap for DER Integration in India: Industry Best Practices and Resource Guide

Ensuring safe, reliable, cost-effective DER integration at scale requires holistic planning, broad stakeholder engagement, and should address key development areas such as standards adoption, equipment testing and certification, interoperability and cybersecurity, interconnection procedures, and advanced forecasting and DER management. Each of these areas currently represent significant challenges for utilities, regulators, OEMs, developers, and even consumers worldwide. India has already seen significant growth of DERs and has announced targets for substantial growth yet to come, with the potential for DERs to make up a non-negligible portion of the country's overall generation capacity. As such, it is of critical importance that Indian stakeholders consider the potential impacts of wide-spread adoption of DERs and take preemptive action related to the five development areas listed here, among others. India should consider strategies including the adoption of key DER standards related to interconnection, testing, and cybersecurity; enabling effective and secure communication channels for DER interoperability; testing and certifying DER equipment in accredited testing laboratories; building robust, streamlined interconnection procedures; and revamping legacy system planning structures to incorporate DERs in a holistic planning framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurement and Reporting Guidelines for Solar Mirror Aging Tests Using Xenon Arc Lamp Exposure (XALE)

This technical report provides a guideline for accelerated aging tests on solar reflectors. Solar reflectors must have a high durability, with goal lifespans reaching 30 years. To test and develop state-of-the-art solar reflectors, relevant durability tests must be conducted. Existing guidelines for materials testing include isothermal testing, humidity testing, corrosion, etc., but many tests do not specify to include solar irradiance or address its relevance to solar reflector durability. The guideline focuses on test design and reporting guidelines for using Xenon Arc Lamp Exposure (XALE). The XALE environmental chambers can subject samples to a combination of relevant environmental factors including concentrated solar irradiance, heat, humidity, and weathering cycles. The guideline is meant to provide information on developing relevant test conditions, exposure times, reflectance characterization procedures, and data reporting.

14 SOLAR ENERGY↗

Mechanical properties as an indicator of interstitials in niobium for superconducting accelerator cavities

A preliminary investigation was conducted into the feasibility of using simple mechanical properties experiments to evaluate interstitial impurity uptake from processing environments. Two types of tests were examined: tensile tests and complex modulus measurements using a dynamic mechanical analyzer (DMA). For the tensile tests, samples were cut from a single crystal of niobium, with the same orientation, and then prepared following different procedures. Significant differences were observed during tensile tests, with yielding strength and strain-to-failure clearly related to interstitial uptake. When the strain rate was reduced by an order of magnitude, the strain-to-failure was reduced by 18 % indicating that interstitial hydrogen is responsible for this behavior. For the complex modulus measurement, polycrystalline samples from different locations of two different ingots were examined at a frequency of 1.0 Hz while the temperature was increased at the rate of 1.0 °C per minute. Anaelastic peaks were found for C, N, and O in all samples, but the lower limit of the system did not allow for detection of a peak for H. It is concluded that mechanical properties could be developed as a measurement tool to guide the development of processing methods for producing reduced interstitial content material, but additional research, and uncertainty analysis, is required for these tools to be reliable in this application.

36 MATERIALS SCIENCE↗

Knowledge-Based Hazardous Waste Determinations for Solar Photovoltaic (PV) Modules: A Foundational Study

This report explores using "generator knowledge" to determine whether a solar photovoltaic (PV) module must be managed as hazardous waste prior to recycling or landfilling. Generator knowledge is a legal term and existing regulatory pathway for making a hazardous waste determination that has been used by other industries but is a relatively unknown option to the PV industry. In the United States, a hazardous waste determination often acts as a pre-requisite to recycle or landfill a PV module. The results of the hazardous waste determination dictate whether the PV module must be managed as hazardous waste or nonhazardous solid waste. Managing a PV module as hazardous waste requires compliance with stringent U.S. federal and state hazardous waste law. In addition to increased management costs, which can be ten times higher, legal liability for PV modules regulated as hazardous waste is also heightened with both civil and criminal penalties for noncompliance which includes making an inaccurate or faulty hazardous waste determination. The most common reason a PV module would be regulated as hazardous is if it contains a regulated metal in an amount that equals or exceeds the toxicity characteristic limits. To determine whether a PV module exhibits a hazardous characteristic, the regulated person/entity must "apply knowledge...in light of the materials and processes used." In the absence of adequate knowledge to determine whether the PV module is hazardous, it must be tested using Test Method 1311 Toxicity Characteristic Leaching Procedure (TCLP) or an equivalent EPA-approved method. Although TCLP is the predominant method used to today to make a hazardous waste determination for PV modules, evidence from this study concludes it is not practical to TCLP test every PV module even in a single utility-scale installation, and a scalable solution is needed. This study finds that knowledge-based hazardous waste determinations may allow a regulated person/entity to make a hazardous waste determination for more than one PV module at one time - making this regulatory pathway a potential scalable solution. Through legal analysis and interviews with 44 experts, the authors explore what it means to make an accurate knowledge-based hazardous determination for PV modules considering sources and forms of information as well as potential limitations. The work aims to provide a foundation for building consensus on whether knowledge-based hazardous determinations are a viable, scalable industry approach for solar.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Draft Plan to Develop Non-Intrusive Load Monitoring Test Protocols

This document presents a Draft Plan proposed to develop a common test protocol that can be used to evaluate the performance requirements of Non-Intrusive Load Monitoring. Development on the test protocol will be focused on providing a consistent method that can be used to quantify and compare the performance characteristics of NILM products. Elements of the protocols include specifications for appliances to be used, metrics, instrumentation, and a procedure to simulate appliance behavior during tests. In addition, three priority use cases for NILM will be identified and their performance requirements will specified.

47 OTHER INSTRUMENTATION↗

Insulation Coordination Design for Grid-Connected Solid-State Transformers

The deployment of solid-state transformers (SSTs) in medium-voltage (MV) distribution systems is facing various challenges, especially the challenge of insulation coordination design against grid-originated lightning impulses. In this article, two challenges in existing insulation coordination designs for grid-connected SSTs are identified. One challenge is the mismatch between metal-oxide varistor (MOV) protective levels and SST insulation strength, the other challenge is the incompatibility of standard impulse test on SST protective structures. To address the MOV selection challenge, a novel lightning protection scheme is designed to protect a single-stage SST where the semiconductor modules are directly exposed to external lightning impulses. Here, the in-lab lightning impulse tests are performed to verify the overvoltage attenuation performance of the prototyped lightning protection scheme. To address the impulse test challenge, the surge withstand capability of the protected SST is comprehensively evaluated with a complete set of insulation coordination design procedures beyond the basic insulation level (BIL) test. After these two challenges are addressed, a discussion is presented on substituting conventional transformers with the protected SSTs into insulation-coordinated distribution systems to facilitate the field deployment of SSTs.

solid-state transformer (SST)↗

SU-F-T-226: QA Management for a Large Institution with Multiple Campuses for FMEA

Purpose: To redesign our radiation therapy QA program with the goal to improve quality, efficiency, and consistency among a growing number of campuses at a large institution. Methods: A QA committee was established with at least one physicist representing each of our six campuses (22 linacs). Weekly meetings were scheduled to advise on and update current procedures, to review end-to-end and other test results, and to prepare composite reports for internal and external audits. QA procedures for treatment and imaging equipment were derived from TG Reports 142 and 66, practice guidelines, and feedback from ACR evaluations. The committee focused on reaching a consensus on a single QA program among all campuses using the same type of equipment and reference data. Since the recommendations for tolerances referenced to baseline data were subject to interpretation in some instances, the committee reviewed the characteristics of all machines and quantified any variations before choosing between treatment planning system (i.e. treatment planning system commissioning data that is representative for all machines) or machine-specific values (i.e. commissioning data of the individual machines) as baseline data. Results: The configured QA program will be followed strictly by all campuses. Inventory of available equipment has been compiled, and additional equipment acquisitions for the QA program are made as needed. Dosimetric characteristics are evaluated for all machines using the same methods to ensure consistency of beam data where possible. In most cases, baseline data refer to treatment planning system commissioning data but machine-specific values are used as reference where it is deemed appropriate. Conclusion: With a uniform QA scheme, variations in QA procedures are kept to a minimum. With a centralized database, data collection and analysis are simplified. This program will facilitate uniformity in patient treatments and analysis of large amounts of QA data campus-wide, which will ultimately facilitate FMEA.

43 PARTICLE ACCELERATORS↗

Tank 50 Simulant Grout and Toxicity Characteristic Leaching Procedure (TCLP) Results for Methyl Mercury Waste Acceptance Criteria (WAC) Limit

Testing of simulated Tank 50 salt solution grout, spiked with methyl mercury (MeHg) and ionic mercury, used the Toxicity Characteristic Leaching Procedure (TCLP) to evaluate leaching performance with respect to Hg and the Waste Acceptance Criteria (WAC) limits for the Saltstone Production Facility (SPF). This report describes the test parameters for simulant preparation and confirmatory analysis, grout preparation, TCLP leach testing and subsequent leachate analyses. These scoping tests were designed to provide an initial evaluation of the effect of increased MeHg and ionic Hg on the TCLP and were requested by Savannah River Remediation LLC (SRR) through a Technical Assistance Request (TAR). It is expected that this preliminary testing will likely lead to future, more detailed, testing involving the mercury (Hg) WAC and Hg limits with respect to the Tank 50 TCLP for mercury. The TCLP concentrations for total Hg have approached 0.06 mg/L in recent years for Tank 50 radioactive solutions containing up to 105 mg/L of Hg in the form of ionic (Hg(I/II), elemental (Hg(0)) and organo-mercury such as MeHg. In discussions with SRR personnel, it was decided for this non-baseline work to target Hg spike concentrations, using predominately MeHg, in the range of 150 to 350 mg/L total Hg to investigate corresponding Hg TCLP leaching behaviors.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of pH-dependent environmental protection agency test method 1313 to low-activity nuclear waste glass

Here, in this study, we present results of a room temperature, pH-dependent leach test established by United States Environmental Protection Agency (EPA) Leaching Environmental Assessment Framework (LEAF) (EPA Method 1313 and further abbreviated EPA 1313) to study the alteration behavior of low-activity nuclear waste (LAW) glasses. Implementation of EPA 1313, which is closer to LAW disposal temperatures, could allow for more flexibility in the formulation of Hanford LAW glasses, specifically in terms of increased waste loading. A set of 48 LAW glasses were selected to test with EPA 1313. Briefly, the test method consists of adding glass to a number of solutions at different initial pH values and at a fixed mass-to-solution-volume ratio. The glass is then allowed to corrode for two days and the final solution pH and concentration of different glass elements in solution is measured. The test was modified from the published procedure to constrain particle size to provide more reproducible results, reduce the studied pH range to a more applicable range, and to reduce solution volume to reduce costs associated with material preparation. Compositional modeling was used to predict the measured elemental releases at various pH. The model predictions improved in tests where there was a relatively small difference between initial and final solution pH indicating that pH controls would result in better predictive models.

Accelerated aging↗