Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal Energy Distribution System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Shunt-Connected FACTS and Synchronous Condensers

In recent years, the electric-transmission system has undergone a significant transformation marked by a greater integration of renewable-energy sources like wind and solar, the phasing out of thermal generation plants, and a concerted effort towards electrifying energy consumption. To keep pace with the integration of renewable-energy sources and the escalating demands of industries and households, it is imperative to expand and modernize the existing power infrastructure. These upgrades are essential to maintain grid stability, enhance power delivery, and boost overall efficiency of the system. However, challenges have emerged with the growing complexity of power grids, particularly in the realms of voltage control, transient stability, and power-quality management.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Hot carrier extraction from 2D semiconductor photoelectrodes

Hot carrier-based energy conversion systems could double the efficiency of conventional solar energy technology or drive photochemical reactions that would not be possible using fully thermalized, “cool” carriers, but current strategies require expensive multijunction architectures. Using an unprecedented combination of photoelectrochemical and in situ transient absorption spectroscopy measurements, we demonstrate ultrafast (<50 fs) hot exciton and free carrier extraction under applied bias in a proof-of-concept photoelectrochemical solar cell made from earth-abundant and potentially inexpensive monolayer (ML) MoS 2 . Our approach facilitates ultrathin 7 Å charge transport distances over 1 cm 2 areas by intimately coupling ML-MoS 2 to an electron-selective solid contact and a hole-selective electrolyte contact. Our theoretical investigations of the spatial distribution of exciton states suggest greater electronic coupling between hot exciton states located on peripheral S atoms and neighboring contacts likely facilitates ultrafast charge transfer. Our work delineates future two-dimensional (2D) semiconductor design strategies for practical implementation in ultrathin photovoltaic and solar fuel applications.

2D materials↗

Accelerated Aging of PV Cables - The Development of Methods Towards Combined-Accelerated Stress Testing

PV cables allow the collection and distribution of electricity from modules to the energy grid. Durable cabling allows continuous operation of PV installations. Cables with a life less than that of the modules must be replaced - reducing electricity generation and adding to the system operating expense. We have examined the durability of a variety of representative cable samples using artificial UV weathering (IEC TS 62788-7-2) and combined accelerated stress testing (C-AST). Jackets in this study include PV-rated (polyolefin), building wire (PVC/PA), and multi-conductor (rubber, as in PV trackers), with some examples of black and red cables. Characterizations at read points include appearance (camera and optical microscope), surface roughness (linear profilometry), instrumented indentation, surface morphology (SEM), chemical composition (EDS), thermal decomposition (TGA), phase transition (DSC), crystalline structure (WAXS), and polymer chemical structure (FTIR). Complimentary examinations confirm damage to the external and interior layer(s) of less durable samples, including changes in morphology (e.g., cracking), chemistry (e.g., oxidation), structure, and mechanical performance (e.g., through-thickness modulus and hardness). The results may be generally compared to other examples from the field (PV installations) or after accelerated testing (IEC 61215). The methods in this study are presently being applied in a follow-on C-AST study, incorporating both dynamic and kinematic fixtures.

balance of systems↗

Initial Operation of the Nuclear Thermal Rocket Element Environmental Simulator

The Nuclear Thermal Rocket Element Environmental Simulator (NTREES) facility is designed to perform realistic non-nuclear testing of nuclear thermal rocket (NTR) fuel elements and fuel materials. Although the NTREES facility cannot mimic the neutron and gamma environment of an operating NTR, it can simulate the thermal hydraulic environment within an NTR fuel element to provide critical information on material performance and compatibility. The NTREES facility has recently been upgraded such that the power capabilities of the facility have been increased significantly. At its present 1.2 MW power level, more prototypical fuel element temperatures nay now be reached. The new 1.2 MW induction heater consists of three physical units consisting of a transformer, rectifier, and inverter. This multiunit arrangement facilitated increasing the flexibility of the induction heater by more easily allowing variable frequency operation. Frequency ranges between 20 and 60 kHz can accommodated in the new induction heater allowing more representative power distributions to be generated within the test elements. The water cooling system was also upgraded to so as to be capable of removing 100% of the heat generated during testing In this new higher power configuration, NTREES will be capable of testing fuel elements and fuel materials at near-prototypic power densities. As checkout testing progressed and as higher power levels were achieved, several design deficiencies were discovered and fixed. Most of these design deficiencies were related to stray RF energy causing various components to encounter unexpected heating. Copper shielding around these components largely eliminated these problems. Other problems encountered involved unexpected movement in the coil due to electromagnetic forces and electrical arcing between the coil and a dummy test article. The coil movement and arcing which were encountered during the checkout testing effectively destroyed the induction coil in use at the time and resulted in NTREES being out of commission for a couple of months while a new stronger coil was procured. The new coil includes several additional pieces of support structure to prevent coil movement in the future. In addition, new insulating test article support components have been fabricated to prevent unexpected arcing to the test articles. Additional activities are also now underway to address ways in which the radial temperature profiles across test articles may be controlled such that they are more prototypical of what they would encounter in an operating nuclear engine. The causes of the temperature distribution problem are twofold. First, the fuel element test article is isolated in NTREES as opposed to being in the midst of many other mostly identical fuel elements in a nuclear engine. As a result, the fuel element heat flux boundary conditions in NTREES are far from adiabatic as would normally be the case in a reactor. Second, induction heating skews the power distribution such that power is preferentially deposited near the outside of the fuel element. Nuclear heating, conversely, deposits its power much more uniformly throughout the fuel element. Current studies are now looking at various schemes to adjust the amount of thermal radiation emitted from the fuel element surface so as to essentially vary the thermal boundary conditions on the test article. It is hoped that by properly adjusting the thermal boundary conditions on the fuel element test article, it may be possible to substantially correct for the inappropriate radial power distributions resulting from the induction heating so as to yield a more nearly correct temperature distribution throughout the fuel element.

Emrich, William J., Jr.↗

Laser Powder Directed Energy Deposition of Steels for Nuclear Applications

This comprehensive investigation examines the structure–property relationships in two nuclear alloy systems—Alloy 709 (A709) austenitic stainless steel and Grade 92 (G-92) ferritic/martensitic (F/M) steel—manufactured via directed energy deposition (DED) for sodium-cooled fast reactor applications. This study establishes the fundamental mechanisms for controlling microstructures for optimizing the mechanical performance of additively manufactured nuclear materials through systematic heat treatment optimization and multiscale characterization. As-deposited A709 steel develops a complex multiscale strengthening architecture consisting of a fine cellular solidification structure with diameter of 2-3 µm within10–50 µm grains, elevated dislocation densities from rapid thermal cycling, and grain boundary precipitates that activate concurrent Hall–Petch, dislocation, and precipitation hardening mechanisms to achieve exceptional properties [yield strength (YS): 603 MPa, ultimate tensile strength (UTS): 844 MPa, Vickers hardness: 220 HV] that achieve a 44% superior strength compared to that of the wrought material. Heat treatments produce different results. Solution annealing (SA) dissolves the cellular structure and reduces the hardness to 190 HV. Precipitation treatment (PT) keeps the cellular structure but adds carbides, allowing the hardness to reach 205 HV. The best approach combines both treatments (SA+PT) and creates uniform precipitate distributions with M 23 C 6 carbides at the grain boundaries and MX carbonitrides in the matrix, achieving a hardness of 195 HV. However, directional differences persist, with a 12%–15% strength variation between orientations due to the inherited layered microstructural architecture that survives aggressive heat treatment. While tensile testing at 550°C demonstrates 40%–50% thermal softening with dynamic strain aging, DED A709 steel still maintains a 71% higher YS than that of the wrought material. Ion irradiation studies (100–400 dpa) of DED A709 steel reveal progressive radiation damage with increasing void density and radiation-induced segregation causing nickel enrichment and chromium depletion, which will ultimately compromise mechanical properties. As-deposited G-92 exhibits exceptional strength (UTS: 1650–1700 MPa, 430 HV) through a complex microstructure containing both ferrite and martensite phases, a high geometrically necessary dislocation (GND) density (17.04×10 14 /m 2 ), and fine carbides. Heat treatments create distinct changes. Normalizing produces fresh martensite with the highest hardness (460 HV) and an increased GND density (20.23×10 14 /m 2 ). Tempering develops dual precipitation systems and reduces the hardness to 290 HV. The optimal approach uses sequential normalizing plus tempering, achieving balanced properties with the lowest hardness (250 HV) and a reduced GND density (11.01×10 14 /m 2 ). A processing-dependent anisotropy is observed: horizontal specimens achieve superior ductile behavior, while vertical specimens exhibit brittle failure. A tempering heat treatment successfully mitigates this anisotropic behavior by transforming the hard martensitic as-deposited structure into tempered martensite enabling both horizontal and vertical specimens to exhibit similar stress–strain characteristics with visible necking behavior. Remarkably, testing at 550°C reveals a reversal in the anisotropy, where as-deposited specimens achieve near isotropy with superior thermal stability (a 15%–20% strength reduction), while tempered specimens develop an orientation dependence with a 25%–30% strength reduction. Both alloy systems demonstrate that DED processing creates specimens with a superior strength through refined microstructural features, though with distinct strengthening mechanisms—austenitic through cellular structures and precipitates versus F/M through phase transformations and precipitates. Heat treatment optimization requires alloy-specific approaches, with A709 benefiting from controlled precipitation while G-92 requires careful phase transformation control. The results show that DED manufacturing can produce nuclear materials with exceptional performance, but directional effects and temperature-dependent behavior must be carefully considered for reactor component design and qualification.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Large- and Small-Scale Ring Current Electrodynamic Coupling

In this talk we will address the two primary issues of ring current (RC) electrodynamic coupling: 1. RC self-consistent magnetosphere-ionosphere coupling that includes calculation of the magnetospheric electric field (large scale electrodynamic coupling); and 2. RC self-consistent coupling with electromagnetic ion cyclotron (EMIC) waves (small scale electrodynamic coupling). Our study will be based on two RC models that we have recently developed in our group. The first model by Khazanov et al. [2002] couples the system of two kinetic equations: one equation which describes the RC ion dynamics and another equation which describes the energy density evolution of EMIC waves. The second model by Khazanov et al. [2003] deals with large scale electrodynamic coupling processes and provides a self-consistent simulation of RC ions and the magnetospheric electric field. There is presently no model that addresses both of these issues simultaneously in a self-consistent calculation. However, the need exists for such a model, because these two processes directly influence each other, with the mesoscale coupling changing the drift paths of the thermal and energetic particle populations in the inner magnetosphere, thereby changing the wave interactions, and the microscale coupling altering the pitch angle distributions and ionospheric conductivities (through increased precipitation), thus changing the field-aligned currents and electric potential structure. The initial thrust of the work will be the development of a combined kinetic model of micro- and meso-scale RC electrodynamic coupling processes and to examine their interactions with each other on a global scale.

Khazanov, G. V.↗

Solar heating system at Quitman County Bank, Marks, Mississippi

Information on the Solar Energy Heating System installed in a single story wood frame, cedar exterior, sloped roof building is presented. The system has on-site temperature and power measurements readouts. The 468 square feet of Solaron air flat plate collectors provide for 2,000 square feet of space heating, an estimated 60 percent of the heating load. Solar heated air is distributed to the 235 cubic foot rock storage box or to the load (space heating) by a 960 cubic feet per minute air handler unit. A 7.5 ton Carrier air-to-air heat pump with 15 kilowatts of electric booster strips serve as a back-up (auxiliary) to the solar system. Motorized dampers control the direction of airflow and back draft dampers prevent thermal siphoning of conditioned air.

Source record↗

Development of an integrated heat pipe-thermal storage system for a solar receiver

An integrated heat pipe-thermal storage system was developed as part of the Organic Rankine Cycle Solar Dynamic Power System solar receiver for space station application. The solar receiver incorporates potassium heat pipe elements to absorb and transfer the solar energy within the receiver cavity. The heat pipes contain thermal energy storage (TES) canisters within the vapor space with a toluene heater tube used as the condenser region of the heat pipe. During the insolation period of the earth orbit, solar energy is delivered to the heat pipe. Part of this thermal energy is delivered to the heater tube and the balance is stored in the TES units. During the eclipse period of earth orbit, the stored energy in the TES units is transferred by the potassium vapor to the toluene heater tube. A developmental heat pipe element was constructed that contains axial arteries and a distribution wick connecting the toluene heater and the TES units to the solar insolation surface of the heat pipe. Tests were conducted to demonstrate the heat pipe, TES units, and the heater tube operation. The heat pipe element was operated at design input power of 4.8 kW. Thermal cycle tests were conducted to demonstrate the successful charge and discharge of the TES units. Axial power flux levels up to 15 watts/sq cm were demonstrated and transient tests were conducted on the heat pipe element. Details of the heat pipe development and test procedures are presented.

Keddy, E.↗

Ring Current Electrodynamic Coupling

In this talk we will address the two primary issues of ring current (RC) electrodynamic coupling: 1. RC self-consistent coupling with electromagnetic ion cyclotron (EMIC) waves (small scale electrodynamic coupling); and 2. RC self-consistent magnetosphere-ionosphere coupling that includes calculation of the magnetospheric electric field (large scale electrodynamic coupling). Our study will be based on two RC models that we have recently developed in our group. The first model by Khazanov et al. [2002, 20031 couples the system of two kinetic equations: one equation which describes the RC ion dynamics and another equation which describes the energy density evolution of EMIC waves. The second model by Khazanov et al. [2003] deals with large scale electrodynamic coupling processes and provides a self-consistent simulation of RC ions, electrons and the magnetospheric electric field. There is presently no model that addresses both of these issues simultaneously in a self-consistent calculation. However, the need exists for such a model, because these two processes directly influence each other, with the mesoscale coupling changing the drift paths of the thermal and energetic particle populations in the inner magnetosphere, thereby changing the wave interactions, and the microscale coupling altering the pitch angle distributions and ionospheric conductivities (through increased precipitation), thus changing the field-aligned currents and electric potential structure. The initial thrust of the work will be the development of a combined kinetic model of micro- and meso-scale RC electrodynamic coupling processes and to examine their interactions with each other on a global scale. We also discuss the nonlinear coupling of EMIC and lower hybrid waves in the RC region during the May 2-7, 1998 storm period.

Khazanov, G. V.↗

Innovative Thermal Strategies: Electrification's Best Friend

Because transportation and heat are the most significant contributors to greenhouse gas (GHG) emissions in the northern U.S., electrification of transport and heat are prominent elements of many decarbonization plans, such as that of New York State (NYS). A key challenge is then to decarbonize the electric supply and distribution system ("the grid") that supplies electricity, a process colloquially known as "greening the grid", so that the saved direct carbon emissions are not offset by additional indirect emissions from electrical generation on the grid. Applying this "simple" decarbonization plan to locations with high winter heating loads and modest renewable resources is challenging. Understanding the impact of thermal system design to grid demands in these locations and the related marginal power source for electrification options is critical to allocating proper resources to solve decarbonization challenges and quantifying the resultant carbon emissions impact.

battery storage↗

Integrated Bosch Process System Models for In-Situ Oxygen and Carbon Production

In-Situ Resource Utilization (ISRU) technology is a vital component to NASA’s mission of a sustainable presence on the Moon and Mars. Local resources can be leveraged to reduce resupply frequency and mass. Elements of the Bosch process, combined with the carbothermal reduction process, can produce oxygen on the lunar surface with minimal consumables. The Bosch process can also produce oxygen on the Martian surface by using the CO 2 -rich environment. Between both systems, adsorption pump, solar thermal energy, carbon formation reactor, and water recovery subsystems are modeled and integrated to create a functional model in MATLAB software. The model is used to simulate performance of the system and reduce mass, power, and volume requirements. This integrated system model provides a tool to scale ISRU technologies for oxygen and carbon production. The MATLAB model is created by developing a system of independent subsystem models that are solved for their quasi-steady state values which can be integrated with respect to time to determine the change in current states. A flexible time stepping method is used to ensure a high level of accuracy during periods of rapid change while still making use of a simple explicit integration method. The flexible time step is calculated for each independent subsystem and the minimum value from those is used as the overall time step. A flexible time step is calculated by dividing a resolution value, or the maximum change per time step, by the variables current rate of change. The maximum value from all points in space is used for subsystem models that contain multiple values. The process is done for every variable that is being monitored in each subsystem and the global minimum is used as that iteration’s timestep. Several assumptions used in the MATLAB model for fluid flow dynamics, such as 1-D gas flow through the sorption pump, are supported by modeling in Ansys Fluent software. The Lunar oxygen production system is outlined in Fig. 1. The carbothermal reduction subsystem uses solar energy to heat a mixture of lunar regolith and carbon powder to produce carbon monoxide. To begin, the carbon monoxide feeds to the modified Bosch subsystem along with hydrogen gas. The reactants then enter the carbon formation reactor where water and carbon powder are produced. Solar thermal energy is used to add energy to the reactor, but waste heat from the carbothermal process is another potential heat source. The water is collected and electrolyzed to produce hydrogen which reenters the Bosch subsystem, and the oxygen is stored for downstream use. The carbon powder is collected and feeds back into the carbothermal subsystem. The Martian oxygen production system uses the full Bosch process and is outlined in Fig 2. A CO 2 adsorption pump thermally cycles to scrub and pressurize CO 2 from the environment. Along with an initial supply of hydrogen, the reactants enter the Reverse Water Gas Shift Reactor (RWGSR) which produces carbon monoxide and water. Carbon monoxide and unreacted hydrogen enter the carbon formation reactor to produce water and carbon powder. The water is collected from both reactors and electrolyzed to reintroduce hydrogen and store oxygen for propellant production or life support. Carbon is removed from the carbon formation reactor and stored. The adsorption pump utilizes rapid cycle temperature swings within a stack of zeolite coated surfaces. The subsystem model solves 1-D quasi-steady conservation laws of the quasi-steady form, shown in Eq. 1, for the gas stream and heat exchange liquid to predict performance parameters such as breakthrough capacity and optimum cycle time. The source term S is used to capture interactions between the fluid flows and the sorbent. A quasi-steady-state scheme is used where no time derivatives appear in the governing equations, except for those in the source terms. This results in an autonomous system, where ∂F/∂x = ƒ(F). The fluxes F are provided at the inlet, and an explicit method is used to solve for the spatial distribution of F. The heat and mass flows to the sorbent are then extracted from the source terms. These flows are numerically integrated to produce a 1-D solution for the system’s state as a function of both time and space. The body of the adsorption pump is separated into two semi-independent models: the heat exchanger fluid flow and gas flow through the zeolite coated surfaces. Both models are solved using the above-described method to find a 1-D solution as a function of space and interact only once a timestep is taken. The interaction point is the sorbent through which all heat transfer between the two models must occur. Sorbent mass adsorption is calculated using the Lagergren model, shown in Eq. 2, where the transfer coefficient, λ D , is found by solving a system of nondimensionalized equations derived by using the heat and mass transfer analogy for transport phenomena. Using Grade 544 Type 13X zeolite as the sorbent material, the equilibrium concentration, θ eq , is calculated using the k-site Langmuir isotherm and fit parameters. Additionally, the enthalpy of adsorption used in the model is computed by interpolation of available data [1]. The subsystem model was validated using the Rapid Cycle Temperature Swing Adsorption (RC-TSA) pump. The solar thermal energy subsystem focuses on a solar concentrator concept with a heat exchanger to heat the reactants before entering the carbon formation reactor. The subsystem model assumes a fixed solar flux and reflector efficiency to calculate the reactant temperature given the incoming temperature, pressure, and exchanger geometry. The receiver is a custom manufactured series of copper blocks with serpentine channels to increase its surface area and the residence time of the reactants to heat up to 550 °C. The subsystem model was validated using a heat exchanger developed at NASA Glenn Research Center (GRC). The solar thermal energy subsystem focuses on a solar concentrator concept with a heat exchanger to heat the reactants before entering the carbon formation reactor. The subsystem model assumes a fixed solar flux and reflector efficiency to calculate the reactant temperature given the incoming temperature, pressure, and exchanger geometry. The receiver is a custom manufactured series of copper blocks with serpentine channels to increase its surface area and the residence time of the reactants to heat up to 550 °C. The subsystem model was validated using a heat exchanger developed at NASA Glenn Research Center (GRC).

In situ Resource Utilization↗

Thermal Runaway of Li-Ion Cells: How Internal Dynamics, Mass Ejection, and Heat Vary with Cell Geometry and Abuse Type

Thermal runaway of lithium-ion batteries can involve various types of failure mechanisms each with their own unique characteristics. Using fractional thermal runaway calorimetry and high-speed radiography, the response of three different geometries of cylindrical cell (18650, 21700, and D-cell) to different abuse mechanisms (thermal, internal short circuiting, and nail penetration) are quantified and statistically examined. Correlations between the geometry of cells and their thermal behavior are identified, such as increasing heat output per amp-hour (kJ Ah −1 ) of cells with increasing cell diameter during nail penetration. High-speed radiography reveals that the rate of thermal runaway propagation within cells is generally highest for nail penetration where there is a relative increase in rate of propagation with increasing diameter, compared to thermal or internal short-circuiting abuse. For a given cell model tested under the same conditions, a distribution of heat output is observed with a trend of increasing heat output with increased mass ejection. Finally, internal temperature measurements using thermocouples embedded in the penetrating nail are shown to be unreliable thus demonstrating the need for care when using thermocouples where the temperature is rapidly changing. All data used in this manuscript are open access through the NREL and NASA Battery Failure Databank.

25 ENERGY STORAGE↗

Performance and economic risk evaluation of dispersed solar thermal power systems by Monte Carlo simulation

A preliminary comparative evaluation of dispersed solar thermal power plants utilizing advanced technologies available in 1985-2000 time frame is under way at JPL. The solar power plants of 50 KWe to 10 MWe size are equipped with two axis tracking parabolic dish concentrator systems operating at temperatures in excess of 1000 F. The energy conversion schemes under consideration include advanced steam, open and closed cycle gas turbines, stirling, and combined cycle. The energy storage systems include advanced batteries, liquid metal, and chemical. This paper outlines a simple methodology for a probabilistic assessment of such systems. Sources of uncertainty in the development of advanced systems are identified, and a computer Monte Carlo simulation is exercised to permit an analysis of the tradeoffs of the risk of failure versus the potential for large gains. Frequency distribution of energy cost for several alternatives are presented.

Manvi, R.↗

Validation and Demonstration of Control System Functional Capabilities within the IES Plug-and-Play Simulation Environment

The concept of an integrated energy system (IES) is meant to combine different energy technologies in synergistic ways to achieve a more secure and economical energy supply. The RAVEN-based HYBRID framework is used to find the optimal installed capacity and the optimal economical dispatch of each component of the IES. The new RAVEN plugin for grid and capacity optimization (HERON) only addresses the limits that affect the production variables and the corresponding rates of variation (explicit constraints). However, other variables are subject to constraints, and the associated limits should be accounted for (implicit constraints). In particular, for the power dispatch problem, the optimization algorithm takes into account the limits on the electrical power output and the corresponding hourly power variations but does not consider other constraints on process variables whose response affects the service life of the IES. This report describes a scheme that allows accounting for implicit constraints without increasing the size of the optimization problem. To obtain a more accurate approximation of the nonlinear dynamic behavior, a parametric version of the dynamic mode decomposition with control (DMDc) algorithm was developed to derive the state-space representation matrices of the IES components at different scheduling parameter. Thanks to this approach, a more accurate approximation of the system response can be obtained, the limits imposed by thermal mechanical implicit constraints can be translated into power dispatch limits, and the feedbacks to HERON power dispatcher can be provided. To assess the developed methodology, a power dispatching test case composed of three power generating and storage units (Balance of Plant, Secondary Energy Source, Thermal Energy Storage) was developed. The power output of each one of the three units was optimized to meet the imposed time-dependent load demand trajectory and to maximize the IES profitability by meeting both the explicit and implicit constraints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tracer gas test in Net-Zero Energy Residential Test Facility

The Net-Zero Energy Residential Test Facility (NZERTF) at NIST was built in 2012 to support the development and adoption of cost-effective net-zero energy designs, technologies, and construction methods. It is two-story, and has four bedrooms, three bathrooms, and an open living room, dining room, and kitchen space. The NZERTF also has a basement and attic, both located within the conditioned space because the thermal and air-moisture barriers encompass the basement walls and attic roof. Transfer grilles link the living spaces to these two zones. The central heating and cooling system includes an air-toair heat pump, which delivers air to the basement, first and second floors. The heat pump has a cooling capacity of 7.6 kW and a heating capacity of 7.8 kW. The indoor unit is in the basement and ductwork runs along the basement ceiling. A balanced heat recovery ventilator (HRV) is installed in the basement and has its own dedicated ductwork. The HRV supplies 47 L/s of outdoor air to the house, with supplies on the first floor (in the kitchen/dining area) and in each of the three second-floor bedrooms. Air from the first-floor bathroom and both second-floor bathrooms is returned to the HRV before being exhausted, though the HRV was turned off during the tests. The house also has a range hood exhaust and a clothes dryer exhaust, both of which were turned off for the tests. The temperature of the house was measured and the operation of the space conditioning system, including its recirculating air distribution fan, were controlled by a commercially available thermostat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reply to "Comment on 'A Self-Consistent Model of the Interacting Ring Current Ions and Electromagnetic Ion Cyclotron Waves, Initial Results: Waves and Precipitation Fluxes' and 'Self-Consistent Model of the Magnetospheric Ring Current and Propagating Electromagnetic Ion Cyclotron Waves: Waves in Multi-Ion Magnetosphere' by Khazanov et al. et al."

It is well-known that the effects of electromagnetic ion cyclotron (EMIC) waves on ring current (RC) ion and radiation belt (RB) electron dynamics strongly depend on such particle/wave characteristics as the phase-space distribution function, frequency, wavenormal angle, wave energy, and the form of wave spectral energy density. The consequence is that accurate modeling of EMIC waves and RC particles requires robust inclusion of the interdependent dynamics of wave growth/damping, wave propagation, and[ particles. Such a self-consistent model is being progressively developed by Khazanov et al. [2002, 2006, 2007]. This model is based on a system of coupled kinetic equations for the RC and EMIC wave power spectral density along with the ray tracing equations. Thome and Home [2007] (hereafter referred to as TH2007) call the Khazanov et al. [2002, 2006] results into question in their Comment. The points in contention can be summarized as follows. TH2007 claim that: (1) "the important damping of waves by thermal heavy ions is completely ignored", and Landau damping during resonant interaction with thermal electrons is not included in our model; (2) EMIC wave damping due to RC O + is not included in our simulation; (3) non-linear processes limiting EMIC wave amplitude are not included in our model; (4) growth of the background fluctuations to a physically significantamplitude"must occur during a single transit of the unstable region" with subsequent damping below bi-ion latitudes,and consequently"the bounce averaged wave kinetic equation employed in the code contains a physically erroneous 'assumption". Our reply will address each of these points as well as other criticisms mentioned in the Comment. TH2007 are focused on two of our papers that are separated by four years. Significant progress in the self-consistent treatment of the RC-EMIC wave system has been achieved during those years. The paper by Khazanov et al. [2006] presents the latest version of our model, and in this Reply we refer mostly to this paper.

Khazanov, G. V.↗

The NASA program in Space Energy Conversion Research and Technology

The considered Space Energy Conversion Program seeks advancement of basic understanding of energy conversion processes and improvement of component technologies, always in the context of the entire power subsystem. Activities in the program are divided among the traditional disciplines of photovoltaics, electrochemistry, thermoelectrics, and power systems management and distribution. In addition, a broad range of cross-disciplinary explorations of potentially revolutionary new concepts are supported under the advanced energetics program area. Solar cell research and technology are discussed, taking into account the enhancement of the efficiency of Si solar cells, GaAs liquid phase epitaxy and vapor phase epitaxy solar cells, the use of GaAs solar cells in concentrator systems, and the efficiency of a three junction cascade solar cell. Attention is also given to blanket and array technology, the alkali metal thermoelectric converter, a fuel cell/electrolysis system, and thermal to electric conversion.

Mullin, J. P.↗

Programmable Thermostats for MPLM Shell Heater Control ULF1: Thermal Performances - 1

The Multi-Purpose Logistics Module (MPLM) is the primary carrier for "pressurized" logistics to and from the International Space Station (ISS). The MPLM is transported in the payload bay of the Space Shuttle and is docked to the ISS for unloading, and reloading, of contents within the ISS shirt sleeve environment. Foil heaters, controlled originally with bi-metallic thermostats, are distributed across the outside of the MPLM structure and are utilized to provide energy to the structure to avoid exposure to cold temperatures and prevent condensation. The existing bi-metallic, fixed temperature set point thermostats have been replaced with Programmable Thermostats Modules (PTMs) in the Passive Thermal Control Subsystem (PTCS) 28Vdc shell heater circuits. The goal of using the PTM thermostat is to improve operational efficiency of the MPLM on-orbit shell heaters by providing better shell temperature control via feedback control capability. Each heater circuit contains a programmable thermostat connected to an external temperature sensor, a Resistive Temperature Device (RTD), which is used to provide continuous temperature monitoring capability. Each thermostat has programmable temperature set points and control spans. The data acquisition system uses a standard RS-485 serial interface communications cable to provide digital control capability. The PTM system was designed by MSFC, relying upon ALTEC support for their integration within the MPLM system design, while KSC performed the installation and ground checkout testing of the thermostat and RS-485 communication cable on the MPLM FM1 flight module. The PTMs were used for the first time during the STS-121/ULF1.1 mission. This paper will describe the design, development and verification of the PTM system, as well as the PTM flight performance and comparisons with SINDA thermal model predictions.

Glasgow, Shaun↗