Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Calibration, testing and orbital performance of the halogen occultation experiment (HALOE) on the upper atmosphere research satellite

HALOE is an occultation viewing radiometer that requires part per million signal precision and characterization. Gas correlation radiometry is used to infer HF HCl, CH4 and NO concentrations, while broad band radiometry is used for temperature, pressure, O3, H2O and NO2. Validated results verify that goals have been met or exceeded in all channels. This was achieved through a comprehensive instrument analysis and calibration process on the ground and in orbit. Components and systems were put through a battery of tests in the lab. In orbit, a variety of exoatmospheric solar disk measurements are used for precise real time inferral of critical calibration parameters. In the end, technical success was based on the close interaction of scientist, engineer and data analysts. The accuracy and precision of HALOE species profiles are equal to any ever achieved from orbiting sensors.

Gordley, Larry L.↗

Transport Upscaling under Flow Heterogeneity and Matrix-Diffusion in Three-Dimensional Discrete Fracture Networks

For this work, we investigate the combined effects of network scale flow variability and retention due to matrix-diffusion on the scaling behavior of transport through fractured media. Two of the principal mechanisms controlling the transport of solutes through fractured low-permeability media are broad distributions of flow velocities and retention times in the solid matrix. We study the relative impact of these two processes under different initial conditions using a set of three-dimensional discrete fracture network simulations. We use these simulations to develop and calibrate an upscaled continuous time random walk (CTRW) approach for advective transport based on an Ornstein-Uhlenbeck model for the particle velocities that accounts for the fracture-matrix coupling using a compound Poisson process. This CTRW model can be conditioned on the initial solute distribution and allows to observe late-time scaling behavior at distances beyond what is feasible to observe using high-fidelity direct numerical simulations. We determine that the initial distribution of particles leads to marked differences in the persistent long-term scale behavior in the solute travel time distributions, even those undergoing retention due to matrix diffusion through implementation and analysis of the model.

54 ENVIRONMENTAL SCIENCES↗

Toward a Real-Time In Vivo Dosimetry System Using Plastic Scintillation Detectors

Purpose: In the present study, we have presented and validated a plastic scintillation detector (PSD) system designed for real-time multiprobe in vivo measurements. Methods and Materials: The PSDs were built with a dose-sensitive volume of 0.4 mm{sup 3}. The PSDs were assembled into modular detector patches, each containing five closely packed PSDs. Continuous dose readings were performed every 150 ms, with a gap between consecutive readings of <0.3 ms. We first studied the effect of electron multiplication. We then assessed system performance in acrylic and anthropomorphic pelvic phantoms. Results: The PSDs were compatible with clinical rectal balloons and were easily inserted into the anthropomorphic phantom. With an electron multiplication average gain factor of 40, a twofold increase in the signal/noise ratio was observed, making near real-time dosimetry feasible. Under calibration conditions, the PSDs agreed with the ion chamber measurements to 0.08%. Precision, evaluated as a function of the total dose delivered, ranged from 2.3% at 2 cGy to 0.4% at 200 cGy. Conclusion: Real-time PSD measurements are highly accurate and precise. These PSDs can be mounted onto rectal balloons, transforming these clinical devices into in vivo dose detectors without modifying current clinical practice. Real-time monitoring of the dose delivered near the rectum during prostate radiotherapy should help radiation oncologists protect this sensitive normal structure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE LARGE-SCALE BIAS OF DARK MATTER HALOS: NUMERICAL CALIBRATION AND MODEL TESTS

We measure the clustering of dark matter halos in a large set of collisionless cosmological simulations of the flat {Lambda}CDM cosmology. Halos are identified using the spherical overdensity algorithm, which finds the mass around isolated peaks in the density field such that the mean density is {Delta} times the background. We calibrate fitting functions for the large-scale bias that are adaptable to any value of {Delta} we examine. We find a {approx}6% scatter about our best-fit bias relation. Our fitting functions couple to the halo mass functions of Tinker et al. such that the bias of all dark matter is normalized to unity. We demonstrate that the bias of massive, rare halos is higher than that predicted in the modified ellipsoidal collapse model of Sheth et al. and approaches the predictions of the spherical collapse model for the rarest halos. Halo bias results based on friends-of-friends halos identified with linking length 0.2 are systematically lower than for halos with the canonical {Delta} = 200 overdensity by {approx}10%. In contrast to our previous results on the mass function, we find that the universal bias function evolves very weakly with redshift, if at all. We use our numerical results, both for the mass function and the bias relation, to test the peak-background split model for halo bias. We find that the peak-background split achieves a reasonable agreement with the numerical results, but {approx}20% residuals remain, both at high and low masses.

79 ASTRONOMY AND ASTROPHYSICS↗

Toward Calibrated Language for Effectively Communicating the Results of Extreme Event Attribution Studies

Extreme event attribution studies attempt to quantify the role of human influences in observed weather and climate extremes. These studies are of broad scientific and public interest, although quantitative results (e.g., that a specific event was made a specific number of times more likely because of anthropogenic forcings) can be difficult to communicate accurately to a variety of audiences and difficult for audiences to interpret. Here, we focus on how results of these studies can be effectively communicated using standardized language and propose, for the first time, a set of calibrated terms to describe event attribution results. Using these terms and an accompanying visual guide, results are presented in terms of likelihood of event changes and the associated uncertainties. This standardized language will allow clearer communication and interpretation of probabilities by the public and stakeholders.

54 ENVIRONMENTAL SCIENCES↗

Summary of AXAF calibration requirements

The following summarizes requirements on the High Resolution Mirror Assembly (HRMA) and HRMA/SI calibration. The lists of calibration measurements assume that the HRMA meets the CTT requirement that the XRCF test environment shall have not more than a 10 percent effect on the encircled energy in 1 arcsec and that it can be calibrated to 1 percent. This implies that the offloading scheme has been implemented in the HRMA. It should be remembered that there are additional calibrations needed for: aspect system; tracking; gyros; other parts of the PCAS; spacecraft timing and checks on timing accuracy for all SIs after integration in the spacecraft; ficucial lights and periscope; alignments; optical metrology data: lengths and diameters with errors on mirror elements and optical interferometer data on surface figure; and throughput and imaging stability test: an end-to-end test that can be used after the XRCF to verify that the x-ray throughput and imaging quality have not been degraded. The tables presented give a summary of the integration times for HRMA and HRMA/SI calibration.

Kellogg, E.↗

Processing Raw HST Data With Up-to-Date Calibration Data

On-the-Fly Reprocessing (OTFR) is a collection of data-processing routines that work within the context of the Hubble Space Telescope (HST) pipeline data-flow system. The purpose served by OTFR is to generate, on demand, scientifically useful data products from raw HST data stored in an archive. First, on the basis of the requested final data products, OTFR retrieves the corresponding sets of raw data from the archives. Next, OTFR processes the raw data sets to remove artifacts and to establish proper header and other template information. Finally, the calibration routines appropriate to the specific data sets are invoked to produce the requested data products, and the data products are released to an archive distribution system for transmission to the requesting party. OTFR offers two notable advantages: (1) Inasmuch as calibrated data occupy about 8 times as much storage space as do raw data, by obviating storage of calibrated data, OTFR reduces the storage capacity needed by the archive; and (2) the calibration routines can be updated to give requesters the benefit of the most recent calibrations.

Miller, Warren↗

The Calibrations of Space Shuttle Main Engines High Pressure Transducers

Previously, high pressure transducers that were used on the Space Shuttles Main Engine (SSME) exhibited a severe drift after being tested on the SSME. The Experimental Testing Technology Division (ETTD) designed some new transducers that would not exhibit a severe drift over a short period of time. These transducers were calibrated at the Test Bed at Marshall Space Flight Center (MSFC). After the high pressure transducers were calibrated, the transducers were placed on the SSME and fired. The transducers were then sent to the NASA LaRC to be recalibrated. The main objectives of the recalibrations was to make sure that the transducers possessed the same qualities as they did before they were fired on the SSME. Other objectives of the project were to determine the stability of the transducers and to determine whether the transducers exhibited a severe drift.

Steward, Christopher S.↗

NASA ER-2 Doppler radar reflectivity calibration for the CAMEX project

The NASA ER-2 Doppler radar (EDOP) was flown aboard the ER-2 high-altitude aircraft in September and October 1993 for the Convection and Moisture Experiment. During these flights, the first reliable reflectivity observations were performed with the EDOP instrument. This report details the procedure used to convert real-time engineering data into calibrated radar reflectivity. Application of the calibration results produces good agreement between the EDOP nadir pointing reflectivity and ground truth provided by a National Weather Service WSR-88D radar. The rms deviation between WSR-88D and EDOP is 6.9 dB, while measurements of the ocean surface backscatter coefficient are less than 3 dB from reported scatterometer coefficients. After an initial 30-minute period required for the instrument to reach thermal equilibrium, the radar is stable to better than 0.25 dB during flight. The range performance of EDOP shows excellent agreement with aircraft altimeter and meteorological sounding data.

Caylor, I. J.↗

Emulator-Based Bayesian Calibration of the CISNET Colorectal Cancer Models

Purpose To calibrate Cancer Intervention and Surveillance Modeling Network (CISNET)'s SimCRC, MISCAN-Colon, and CRC-SPIN simulation models of the natural history colorectal cancer (CRC) with an emulator-based Bayesian algorithm and internally validate the model-predicted outcomes to calibration targets.Methods We used Latin hypercube sampling to sample up to 50,000 parameter sets for each CISNET-CRC model and generated the corresponding outputs. We trained multilayer perceptron artificial neural networks (ANNs) as emulators using the input and output samples for each CISNET-CRC model. We selected ANN structures with corresponding hyperparameters (i.e., number of hidden layers, nodes, activation functions, epochs, and optimizer) that minimize the predicted mean square error on the validation sample. We implemented the ANN emulators in a probabilistic programming language and calibrated the input parameters with Hamiltonian Monte Carlo-based algorithms to obtain the joint posterior distributions of the CISNET-CRC models' parameters. We internally validated each calibrated emulator by comparing the model-predicted posterior outputs against the calibration targets.Results The optimal ANN for SimCRC had 4 hidden layers and 360 hidden nodes, MISCAN-Colon had 4 hidden layers and 114 hidden nodes, and CRC-SPIN had 1 hidden layer and 140 hidden nodes. The total time for training and calibrating the emulators was 7.3, 4.0, and 0.66 h for SimCRC, MISCAN-Colon, and CRC-SPIN, respectively. The mean of the model-predicted outputs fell within the 95% confidence intervals of the calibration targets in 98 of 110 for SimCRC, 65 of 93 for MISCAN, and 31 of 41 targets for CRC-SPIN.Conclusions Using ANN emulators is a practical solution to reduce the computational burden and complexity for Bayesian calibration of individual-level simulation models used for policy analysis, such as the CISNET CRC models. In this work, we present a step-by-step guide to constructing emulators for calibrating 3 realistic CRC individual-level models using a Bayesian approach.

artificial neural networks↗

How to overcome inter-electrode variability and instability to quantify dissolved oxygen, Fe(II), mn(II), and S(-II) in undisturbed soils and sediments using voltammetry

Background: Although uniquely capable of measuring multiple redox constituents nearly simultaneously with no or minimal sample pretreatment, voltammetry is currently underutilized in characterizing redox conditions in aquatic and terrestrial systems. Investigation of undisturbed media such as pore water requires a solid-state electrode, and such electrodes can be difficult to fabricate reproducibly. An approach to determine the concentrations of electroactive constituents using indirectly calibrated electrodes has been developed, but the protocol for and accuracy of this approach—the pilot ion method—has not been documented in detail. Results: A detailed procedure for testing electrode quality is provided, and the application and limitations of the pilot ion method have been documented. To quantify Fe(II) and Mn(II), subtraction of non-linear baseline functions from voltammetric signals produced better calibration curves than did linear baselines, enabled lower detection limits and reliable deconvolution of overlapping signals, and was successfully applied to sediment pore water signals. We observed that electrode sensitivities often vary by tens of percent, and that the sensitivity declines over time. The ratio of calibration slopes of Mn(II) to Fe(II) varied by no more than 11% from one Hg/Au electrode to another and Fe(II) concentrations predicted by the Mn(II) pilot ion were, on average, 13% different from their actual values. However, concentration predictions by the pilot ion method were worse for less than 15 μM Fe(II) (46% different on average). The ratio of calibration slopes of Mn(II) to S(-II) varied by almost 20% from one Hg/Au electrode to another, and S(-II) predicted concentrations were as much as 58% different from their actual values. These predictions of Fe(II) and S(-II) concentrations indicate that the accuracy of the pilot ion method depends on how independent calibration slope ratios are from the electrode used. At medium-to-high concentration for the ocean, naturally derived dissolved organic carbon did not significantly affect the baseline-corrected electrode response of Mn(II) and Fe(II), but did significantly affect the response of S(-II). Conclusions: Despite their intrinsic variability, Hg/Au electrodes fabricated by hand can be used to quantify O2, S (-II), Fe(II), and Mn(II) without calibrating every electrode for every constituent of interest. The pilot ion method can achieve accuracies to within 20% or less, provided that the underlying principle—the independence of slope ratios—is demonstrated for all voltammetric techniques used, and effects of the physicochemical properties of the system on voltammetric signals are addressed through baseline subtraction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid xenon scintillation measurements and pulse shape discrimination in the LUX dark matter detector

Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter and are expected to produce nuclear recoil (NR) events within liquid xenon time-projection chambers. Here, we present a measurement of liquid xenon scintillation characteristics in the LUX dark matter detector and develop a pulse shaped based discrimination parameter to be used for particle identification. To accurately measure the scintillation characteristics, we develop a template-fitting method to reconstruct the detection time of photons. Analyzing calibration data collected during the 2013-16 LUX WIMP search, we measure a singlet-to-triplet scintillation ratio for electron recoils (ER) that is consistent with existing literature, and we make a first-ever measurement of the NR singlet-to-triplet ratio at recoil energies below 74 keV. A prompt fraction discrimination parameter exploits the difference of the photon time spectra for NR and ER events and is optimized to have the least number of ER events that occur in the 50% NR acceptance region. When this discriminator is used in conjunction with charge-to-light discrimination on the calibration data, the signal-to-noise ratio in the NR dark matter acceptance region increases by up to a factor of two.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AI Driven Experiment Calibration and Control

One critical step on the path from data taking to physics analysis is calibration. For many experiments this step is both time consuming and computationally expensive. The AI Experimental Calibration and Control project seeks to address these issues, starting first with the GlueX Central Drift Chamber (CDC). We demonstrate the ability of a Gaussian Process to estimate the gain correction factor (GCF) of the GlueX CDC accurately, and also the uncertainty of this estimate. Using the estimated GCF, the developed system infers a new high voltage (HV) setting that stabilizes the GCF in the face of changing environmental conditions. This happens in near real time during data taking and produces data which are already approximately gain-calibrated, eliminating the cost of performing those calibrations which vary ±15% with fixed HV. We also demonstrate an implementation of an uncertainty aware system which exploits a key feature of a Gaussian process.

Britton, Thomas↗

Dynamic Black-Level Correction and Artifact Flagging for Kepler Pixel Time Series

Methods applied to the calibration stage of Kepler pipeline data processing [1] (CAL) do not currently use all of the information available to identify and correct several instrument-induced artifacts. These include time-varying crosstalk from the fine guidance sensor (FGS) clock signals, and manifestations of drifting moire pattern as locally correlated nonstationary noise, and rolling bands in the images which find their way into the time series [2], [3]. As the Kepler Mission continues to improve the fidelity of its science data products, we are evaluating the benefits of adding pipeline steps to more completely model and dynamically correct the FGS crosstalk, then use the residuals from these model fits to detect and flag spatial regions and time intervals of strong time-varying black-level which may complicate later processing or lead to misinterpretation of instrument behavior as stellar activity.

Kolodziejczak, J. J.↗

Temperature determinations of hot DA white dwarfs using IUE continuum fluxes

Effective temperatures of 15 DA white dwarfs hotter than 20,000 K were derived from low-dispersion far ultraviolet spectra obtained with IUE. The analysis was carried out by comparing the observed far ultraviolet fluxes with model fluxes scaled to the V-band flux. Accurate calibration of the IUE spectra is critical for this analysis. Observations at all epochs were corrected to the 1980 IUE calibration using the time-dependent corrections of Bohlin (1988). Taking advantage of the smooth and well-defined continuum fluxes provided by DA white dwarfs, seven white dwarfs for which accurate, independent temperature determinations were made from line profile analyses were used to improve the accuracy of the IUE flux calibration. The correction to the original calibration is as great as 20 percent in individual 5 A wavelength bins, while the average over the IUE wavelength range is 5 percent. The final calibration correction and the temperatures for the hot white dwarfs are presented.

Finley, David↗

Qualifying LaBr3:Ce+Sr detector performance for the Mu2e experiment at Fermilab Using the ELBE Accelerator

A LaBr3:Ce+Sr detector will be used to measure the stopped muon captures at the Mu2e experiment at Fermilab. It has been benchmarked in a test beam experiment performed at the ELBE electron accelerator located at the Helmholtz-Zentrum Dresden-Rossendorf, Germany. ELBE’s pulsed bremsstrahlung beam line was set to deliver an average γ -ray energy of between 4–5 MeV. The detector response was mapped to match Mu2e beam conditions, including rates up to 1 Mcps, energy flux, and time structure. A radioactive calibration source was used to mimic the characteristic 1808.7 keV γ -ray, emitted during the atomic muon nuclear capture in the Mu2e aluminum stopping target. The detector energy resolution was measured as a function of the average energy flux: up to 1 TeV/s for 0.34 s, the steady-operation beam-on time and up to 4 TeV/s for 5 ms to get a conservative estimate of the effect of high intensity Mu2e beam fluctuations. The PMT gain variation as a function of the beam spill length and average intensity has been parametrized and corrected for. When a PMT gain correction corresponding to the average beam-spill intensity is applied, the residual effect of beam intensity fluctuations around the average degrades the energy resolution, σ E γ /E γ , at 1808.7 keV from 0.66% to 0.83%.

Huang, Shihua [Purdue U., West Lafayette]↗

Quasi Real Time Data Analysis for Air Quality Monitoring with an Electronic Nose

Cabin Air Quality Monitoring: A) Functions; 1) Incident monitor for targeted contaminants exceeding targeted concentrations. Identify and quantify. 2) Monitor for presence of compounds associated with fires or overheating electronics. 3) Monitor clean-up process. B) Characteristics; 1) Low mass, low power device. 2) Requires little crew time for maintenance and calibration. 3) Detects, identifies and quantifies selected chemical species at or below 24 hour SMAC.

data analysis↗