Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Real-time High-resolution X-Ray Computed Tomography

Computed Tomography (CT) serves as a key imaging technology that relies on computationally intensive filtering and back-projection algorithms for 3D image reconstruction. While conventional high-resolution image reconstruction (> 2K3) solutions provide quick results, they typically treat reconstruction as an offline workload to be performed remotely on large-scale HPC systems. The growing demand for post-construction AI-driven analytics and the need for real-time adjustments call for high-resolution reconstruction solutions that are feasible on local computing resources, i.e. a multi-GPU server at most. In this paper, we propose a novel approach that utilizes Tensor Cores to optimize image reconstruction without sacrificing precision. We also introduce a framework designed to enable real-time execution of end-to-end distributed image reconstruction in a multi-GPU environment. Evaluations conducted on a single Nvidia A100 and H100 GPU show performance improvements of 1.91 × and 2.15 × compared to highly optimized production libraries. Furthermore, our framework, when deployed on 8-card Nvidia A100 GPU system, demonstrates the ability to reconstruct real-world datasets into 20483 volumes (32 GB) in slightly more than one minute and 40963 volumes (256 GB) in 7 minutes.

Wu, Du↗

Time-resolved atomic-resolution Brownian tomography of single nanocrystals reveals size-dependent dynamics

Atomic-resolution structure identification of nanocrystals by graphene liquid cell electron microscopy (GLC-EM) has revealed that small, solubilized platinum nanocrystals consist of an ordered crystalline core surrounded by mobile surface atoms, which dissociate during oxidative etching, resulting in distinct temporal structural states. Requirements imposed by the 3D reconstruction algorithm limit the number of structural states that can be resolved. We introduce a regularized 3D reconstruction algorithm that exploits the redundancy inherent in the experimental data, allowing us to improve the time resolution. Our developments provide a comprehensive molecular picture at unprecedented spatial and temporal resolution of the nonlinear, linear, and fluctuating dynamic phenomena that single nanocrystals undergo during the GLC-EM experiment. We determined atomic structures of 66 temporal structural states, extracted from 15 time trajectories of individual nanocrystals. Large (478 to 698 atoms) and small (<300 atoms) nanocrystals show etching that preserves a stable core, whereas mid-sized (351 to 571 atoms) nanocrystals present dynamics that change the coordination of the core.

Meana-Pañeda, Rubén↗

Advances in High Resolution Ultrafast Scintillators for Fast timing Applications

Scintillation detectors exhibiting high spatial resolution and fast timing capabilities are of vital importance for synchrotron sources. These detectors may be exposed to a variety of X-ray energies (up to 140 keV) and used in high frame rate applications. Here, we describe the advances in the development of thin-film LuI3:Ce scintillators for higher energy X-ray imaging, with fast timing and high spatial resolution. When grown in a single crystalline form, these scintillators are bright, producing 115 000 photons/MeV. However, to achieve high spatial resolution, these scintillators are grown in thin-film form with a microcolumnar structure, controllable to column diameters of <1-30 mu m. Thus, a much thicker scintillator layer (10 mu m-3 mm or higher) may be grown, providing superior X-ray absorption while achieving high resolutions of 50 mu m or better, at the cost of reduced light yield. To study the timing characteristics of the scintillator, time-resolved X-ray excited optical luminescence (TR-XEOL) was performed on two different sets of three samples of LuI3 at the 1-BM beamline of the Advanced Photon Source at Argonne National Laboratory. Besides, we report timing measurements obtained using a photomultiplier tube (PMT) and oscilloscope at Radiation Monitoring Devices (RMD) Inc. Using the TR-XEOL, we determined the decay constants of LuI3 as a function of Ce doping, recording a fast decay component as low as 3.6 ns (39%), one of the fastest values recorded in inorganic scintillators. This fast decay opens up numerous novel applications, where ultrahigh frame rates are important using synchrotron X-rays. This article will discuss fabrication, characterization, and potential applications for this novel scintillator.

fast timing↗

CROCUS Air Quality Dataset from the University of Illinois Chicago (UIC), July 2024

This dataset was collected by the measurement system in the Atmosphere, Climate, and Ecosystems (ACE) Lab at the University of Illinois Chicago (UIC) from July 12 to July 31, 2024, as part of the Community Research on Climate and Urban Science (CROCUS) Urban Integrated Field Laboratory (UIFL) project, led by Argonne National Laboratory.To enhance understanding of urban air quality dynamics in Chicago, and as part of the CROCUS 2024 Urban Canyon Intensive Observation Period (IOP), several instruments were set up to provide continuous measurements of air quality parameters in Chicago during July 2024. These measurements cover both aerosols and gas-phase species. It focuses on particle size distribution (2.5–478 nm) measured by two Scanning Mobility Particle Sizers (SMPS) at a 4-min resolution, total particle number concentrations at a 1-s resolution, and chemical composition from a High-Resolution Time-of-Flight Aerosol Mass Spectrometer (AMS) at a 1-min resolution. Key gas-phase species, including NO, NO₂, SO₂, and O₃, are measured at a 1-min resolution, along with high-resolution NO and dimethyl sulfide (DMS) data from a Chemical Ionization Mass Spectrometer (CIMS). Volatile organic compound (VOC) data for toluene, isoprene, and benzene are provided by a GC-PID with a time resolution of 25 minutes.The data are formatted as NetCDF (.nc) files, making them easily accessible using common software such as MATLAB, R, and Python. Each parameter is stored in an individual dataset, which includes detailed instrument information in the header, as well as the corresponding sample start time and concentration/distribution data for each sample.

54 ENVIRONMENTAL SCIENCES↗

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.

Instruments & Instrumentation↗

Revealing Excited‐State Trajectories on Potential Energy Surfaces with Atomic Resolution in Real Time

Abstract Photoexcited molecular trajectories on potential energy surfaces (PESs) prior to thermalization are intimately connected to the photochemical reaction outcome. The excited‐state trajectories of a diplatinum complex featuring photo‐activated metal–metal σ ‐bond formation and associated Pt−Pt stretching motions were detected in real time using femtosecond wide‐angle X‐ray solution scattering. The observed motions correspond well with coherent vibrational wavepacket motions detected by femtosecond optical transient absorption. Two key coordinates for intersystem crossing have been identified, the Pt−Pt bond length and the orientation of the ligands coordinated with the platinum centers, along which the excited‐state trajectories can be projected onto the calculated PESs of the excited states. This investigation has gleaned novel insight into electronic transitions occurring on the time scales of vibrational motions measured in real time, revealing ultrafast nonadiabatic or non‐equilibrium processes along excited‐state trajectories involving multiple excited‐state PESs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Revealing Excited‐State Trajectories on Potential Energy Surfaces with Atomic Resolution in Real Time

Abstract Photoexcited molecular trajectories on potential energy surfaces (PESs) prior to thermalization are intimately connected to the photochemical reaction outcome. The excited‐state trajectories of a diplatinum complex featuring photo‐activated metal–metal σ ‐bond formation and associated Pt−Pt stretching motions were detected in real time using femtosecond wide‐angle X‐ray solution scattering. The observed motions correspond well with coherent vibrational wavepacket motions detected by femtosecond optical transient absorption. Two key coordinates for intersystem crossing have been identified, the Pt−Pt bond length and the orientation of the ligands coordinated with the platinum centers, along which the excited‐state trajectories can be projected onto the calculated PESs of the excited states. This investigation has gleaned novel insight into electronic transitions occurring on the time scales of vibrational motions measured in real time, revealing ultrafast nonadiabatic or non‐equilibrium processes along excited‐state trajectories involving multiple excited‐state PESs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-resolution neutron time-of-flight measurements for light water at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory

Series of light water inelastic neutron scattering experiments have been made at the Oak Ridge National Laboratory (ORNL), Spallation Neutron Source (SNS) covering temperatures ranging from 295 K to 600 K and pressures of 1 bar and 150 bar. The temperatures and pressures ranges correspond to that of pressurized light water reactors. The inelastic scattering measurements will help the development of light water thermal scattering kernels, also known as S (α,β) thermal scattering law (TSL), in a consistent fashion given the amount and the quality of the measured data. Light water thermal scattering evaluations available in existing nuclear data libraries have certain limitations and pitfalls. This paper introduces the state of the art of the light water thermal scattering cross-section data not only for room temperature but as well as for reactor operating temperatures, i.e. 550 - 600 K. During the past few years there has been a renewed interest in re-investigating the existing TSL models and utilize the recent experimental data or perform molecular dynamics simulations. It should be pointed out that no single TSL evaluation is based entirely on experimental data and one has to rely on TSL models or a combination of both. New TOF measurement of light water at the SNS, with a detailed description of the experimental setup, measurement conditions, and the associated foreseen results is presented in this paper. The analysis of the experimental data would help in validating the existing approach based on old experimental data or based on molecular dynamic simulations using classical water models, knowledge of which is very important to generate TSL libraries at reactor operating conditions.

Leal, Luiz C.↗

First-principles simulation of light-ion microscopy of graphene

The extreme sensitivity of 2D materials to defects and nanostructure requires precise imaging techniques to verify presence of desirable and absence of undesirable features in the atomic geometry. Helium-ion beams have emerged as a promising materials imaging tool, achieving up to 20 times higher resolution and 10 times larger depth-of-field than conventional or environmental scanning electron microscopes. Here, we offer first-principles theoretical insights to advance ion-beam imaging of atomically thin materials by performing real-time time-dependent density functional theory simulations of single impacts of 10–200 keV light ions in free-standing graphene. Here we predict that detecting electrons emitted from the back of the material (the side from which the ion exits) would result in up to three times higher signal and up to five times higher contrast images, making 2D materials especially compelling targets for ion-beam microscopy. This predicted superiority of exit-side emission likely arises from anisotropic kinetic emission. The charge induced in the graphene equilibrates on a sub-fs time scale, leading to only slight disturbances in the carbon lattice that are unlikely to damage the atomic structure for any of the beam parameters investigated here.

36 MATERIALS SCIENCE↗

Improving Spectral Resolution from Real-time Evolution for Correlated Systems

Abstract The quality of numerically simulated spectra using real-time evolution methods for strongly correlated systems is affected by both the length of simulation time and the system size, limiting resolution in both frequency and momentum. In this work, we propose a computationally cheap, linear autoregressive machine learning-based framework to extend short-time and short-distance results over a wider range. We use the proposed method to extend the lesser Green’s function for both the Hubbard model and the much more computationally challenging Hubbard-extended Holstein model. This technique significantly improves both the frequency and momentum resolution of the single-particle removal spectrum $${\mathcal{A}}(k,\omega )$$ A ( k , ω ) , allowing the observation of otherwise obscured spectral features due to electron-phonon coupling.

Tang, Ta↗

Time-Resolved Structural Measurement of Thermal Resistance across a Buried Semiconductor Heterostructure Interface

The precise control and understanding of heat flow in heterostructures is pivotal for advancements in thermoelectric energy conversion, thermal barrier coatings, and efficient heat management in electronic and optoelectronic devices. In this study, we employ high-angular-resolution time-resolved X-ray diffraction to structurally measure thermal resistance in a laser-excited AlGaAs/GaAs semiconductor heterostructure. Our methodology offers femtometer-scale spatial sensitivity and nanosecond time resolution, enabling us to directly observe heat transport across a buried interface. We corroborate established Thermal Boundary Resistance (TBR) values for AlGaAs/GaAs heterostructures and demonstrate that TBR arises from material property discrepancies on either side of a nearly flawless atomic interface. This work not only sheds light on the fundamental mechanisms governing heat flow across buried interfaces but also presents a robust experimental framework that can be extended to other heterostructure systems, paving the way for optimized thermal management in next-generation devices.

36 MATERIALS SCIENCE↗

A first look at AS-ROC: a Si-Ge integrated chip readout for fast timing

Abstract Advances in timing detector technology require new specialized readout electronics. Applications demand below 10 ps time of arrival resolution and low power for a low repetition rate. A possible path to achieve O(10 ps) time resolution is an integrated chip using Silicon Germanium (SiGe) technology. Using DoE SBIR funding, Anadyne, Inc., in collaboration with UC Santa Cruz, has developed a prototype SiGe front-end readout chip optimized for low power and timing resolution. Two versions of the chip were produced with performance in simulation: a more power version with 10 ps resolution at 5 fC with 1.1 mW/channel, and a less power version with 10 ps resolution at 8 fC with 0.6 mW/channel.The chip was produced at Tower Semiconductor with 350 nm technology. The ASIC from the prototype run shows good performance: a rise time of 0.7–1 ns and 25 mV per fC response with RMS noise <1 mV. Simulation and results from the prototype will be reported in this paper.

Instruments & Instrumentation↗

STSR-INR: Spatiotemporal super-resolution for multivariate time-varying volumetric data via implicit neural representation

Implicit neural representation (INR) has surfaced as a promising direction for solving different scientific visualization tasks due to its continuous representation and flexible input and output settings. We present STSR-INR, an INR solution for generating simultaneous spatiotemporal super-resolution for multivariate time-varying volumetric data. Inheriting the benefits of the INR-based approach, STSR-INR supports unsupervised learning and permits data upscaling with arbitrary spatial and temporal scale factors. Unlike existing GAN- or INR-based super-resolution methods, STSR-INR focuses on tackling variables or ensembles and enabling joint training across datasets of various spatiotemporal resolutions. Here we achieve this capability via a variable embedding scheme that learns latent vectors for different variables. In conjunction with a modulated structure in the network design, we employ a variational auto-decoder to optimize the learnable latent vectors to enable latent-space interpolation. To combat the slow training of INR, we leverage a multi-head strategy to improve training and inference speed with significant speedup. We demonstrate the effectiveness of STSR-INR with multiple scalar field datasets and compare it with conventional tricubic+linear interpolation and state-of-the-art deep-learning-based solutions (STNet and CoordNet).

97 MATHEMATICS AND COMPUTING↗

Performance in beam tests of irradiated Low Gain Avalanche Detectors for the ATLAS High Granularity Timing Detector

The High Granularity Timing Detector (HGTD) will be installed in the ATLAS detector to mitigate pile-up effects during the High Luminosity (HL) upgrade of the Large Hadron Collider (LHC) at CERN. The design of the HGTD is based on the use of Low Gain Avalanche Detectors (LGADs), with an active thickness of 50 μm, that allow to measure with high-precision the time of arrival of particles. The HGTD will improve the particle-vertex assignment by measuring the track time with a resolution ranging from approximately 30 ps at the beginning of the HL-LHC operations to 50 ps at the end. Performances of several unirradiated, as well as neutron- and proton-irradiated, LGAD sensors from different vendors have been measured in beam test campaigns during the years 2018 and 2019 at CERN SPS and DESY. This paper presents the results obtained with data recorded by an oscilloscope synchronized with a beam telescope which provides particle position information within a resolution of a few μm. Collected charge, time resolution and hit efficiency are presented. In addition to these properties, the charge uniformity is also studied as a function of the position of the incident particle inside the sensor pad.

47 OTHER INSTRUMENTATION↗