SU-E-T-519: Emission of Secondary Particles From a PMMA Phantom During Proton Irradiation: A Simulation Study with the Geant4 Monte Carlo Toolkit

Purpose: Proton therapy exhibits several advantages over photon therapy due to depth-dose distributions from proton interactions within the target material. However, uncertainties associated with protons beam range in the patient limit the advantage of proton therapy applications. To quantify beam range, positron-emitting nuclei (PEN) and prompt gamma (PG) techniques have been developed. These techniques use de-excitation photons to describe the location of the beam in the patient. To develop a detector system for implementing the PG technique for range verification applications in proton therapy, we studied the yields, energy and angular distributions of the secondary particles emitted from a PMMA phantom. Methods: Proton pencil beams of various energies incident onto a PMMA phantom with dimensions of 5 x 5 x 50 cm3 were used for simulation with the Geant4 toolkit using the standard electromagnetic packages as well as the packages based on the binary-cascade nuclear model. The emitted secondary particles are analyzed . Results: For 160 MeV incident protons, the yields of secondary neutrons and photons per 100 incident protons were ~6 and ~15 respectively. Secondary photon energy spectrum showed several energy peaks in the range between 0 and 10 MeV. The energy peaks located between 4 and 6 MeV were attributed to originate from direct proton interactions with 12C (~ 4.4 MeV) and 16O (~ 6 MeV), respectively. Most of the escaping secondary neutrons were found to have energies between 10 and 100 MeV. Isotropic emissions were found for lower energy neutrons (<10 MeV) and photons for all energies, while higher energy neutrons were emitted predominantly in the forward direction. The yields of emitted photons and neutrons increased with the increase of incident proton energies. Conclusions: A detector system is currently being developed incorporating the yields, energy and angular distributions of secondary particles from proton interactions obtained from this study.

60 APPLIED LIFE SCIENCES↗

SU-E-T-14: A Feasibility Study of Using Modified AP Proton Beam for Post-Operative Pancreatic Cancer Therapy

Purpose: Due to the unpredictability of bowel gas movement, the PA beam direction is always favored for robust proton therapy in post-operative pancreatic cancer treatment. We investigate the feasibility of replacing PA beam with a modified AP beam to take the bowel gas uncertainty into account. Methods: Nine post-operative pancreatic cancer patients treated with proton therapy (5040cGy, 28 fractions) in our institution were randomly selected. The original plan uses PA and lateral direction passive-scattering proton beams. Beam weighting is about 1:1. All patients received weekly verification CTs to assess the daily variations(total 17 verification CTs). The PA direction beam was replaced by two other groups of AP direction beam. Group AP: takes 3.5% range uncertainty into account. Group APmod: compensates the bowel gas uncertainty by expanding the proximal margin to 2cm more. The 2cm margin was acquired from the average bowel diameter in from 100 adult abdominal CT scans near pancreatic region (+/- 5cm superiorly and inferiorly). Dose Volume Histograms(DVHs) of the verification CTs were acquired for robustness study. Results: Without the lateral beam, Group APmod is as robust as Group PA. In Group AP, more than 10% of iCTV D98/D95 were reduced by 4–8%. LT kidney and Liver dose robustness are not affected by the AP/PA beam direction. There is 10% of chance that RT kidney and cord will be hit by AP proton beam due to the bowel gas. Compared to Group PA, APmod plan reduced the dose to kidneys and cord max significantly, while there is no statistical significant increase in bowel mean dose. Conclusion: APmod proton beam for the target coverage could be as robust as the PA direction without sacrificing too much of bowel dose. When the AP direction beam has to be selected, a 2cm proximal margin should be considered.

60 APPLIED LIFE SCIENCES↗

Multiphysics Analysis of Spherical Fast Burst Reactors

Coupling neutronics to thermomechanics is important for the analysis of fast burst reactors, because the criticality and safety study of fast burst reactors depends on the thermomechanical behavior of fuel materials. For instance, the shut down mechanism or the transition between super and subcritical states are driven by the fuel material expansion or contraction. The material expansion or contraction is due to the temperature gradient which results from fission power. In this paper, we introduce a numerical model for coupling of neutron diffusion and thermomechanics in fast burst reactors. The goal is to have a better understanding of the relation between the reactivity insertion and the thermomechanical response of fuel materials. We perform a non-dimensional analysis of the coupled system which provides insight into the behavior of the transient. We also provide a semianalytical solution model to the coupled system for partial verification of our numerical solutions. We studied material behavior corresponding to different levels of reactivity insertion.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Determination of solid/porous wall boundary conditions from wind tunnel data for computational fluid dynamics codes

A computational and experimental study has been undertaken to investigate methods of modeling solid and porous wall boundary conditions in CFD codes. The procedure utilizes experimental measurements at the walls to develop a flow field solution based on the method of singularities. This flow field solution is then imposed as a boundary condition in a CFD simulation of the internal flow field. The effectiveness of this method in describing the boundary conditions at the wind tunnel walls using only sparse experimental measurements has been investigated. Verification of the approach using computational studies has been carried out using an incompressible flow solver. The current work demonstrates this technique for low speed flows and compares the result with experimental data obtained from a heavily instrumented variable porosity test section. Position and refinement of experimental measurements required to describe porous wall boundary conditions has also been considered for application to other porous wall wind tunnels.

Beutner, Thomas J.↗

Radioactive Waste Management: Study of Spent Fuel Dissolution Rates in Geological Storage Using Dosimetry Modeling and Experimental Verification

This research will provide improved predictions into the mechanisms and effects of radiolysis on spent nuclear fuel dissolution in a geological respository through accurate dosimetry modeling of the dose to water, mechanistic chemistry modeling of the resulting radiolytic reactions and confirmatory experimental measurements. This work will combine effort by the Nuclear Science and Engineering Institute (NSEI) and the Missouri University Research Reactor (MURR) at the University of Missouri-Columbia, and the expertise and facilities at the Pacific Northwest National Laboratory (PNNL).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hardware verification of distributed/adaptive control

Adaptive control techniques are studied for their future application to the control of large space structures, where uncertain or changing parameters may destabilize standard control system designs. The approach used is to examine an extended Kalman filter estimator, in which the state vector is augmented with the unknown parameters. The associated Riccatti equation is linearized about the case of exact knowledge of the parameters. By assuming that parameter variations occur slowly, the filter complexity is reduced further yet. Simulations on a two degree-of-freedom oscillator demonstrate the parameter-tracking capability of the filter, and an implementation on the JPL Flexible Beam Facility using an incorrect model shows the adaptive filter/optimal control to be stable where a standard Kalman filter/optimal control design is unstable.

Eldred, D. B.↗

The terminal area simulation system. Volume 2: Verification cases

The numerical simulation of five case studies are presented and are compared with available data in order to verify the three-dimensional version of the Terminal Area Simulation System (TASS). A spectrum of convective storm types are selected for the case studies. Included are: a High-Plains supercell hailstorm, a small and relatively short-lived High-Plains cumulonimbus, a convective storm which produced the 2 August 1985 DFW microburst, a South Florida convective complex, and a tornadic Oklahoma thunderstorm. For each of the cases the model results compared reasonably well with observed data. In the simulations of the supercell storms many of their characteristic features were modeled, such as the hook echo, BWER, mesocyclone, gust fronts, giant persistent updraft, wall cloud, flanking-line towers, anvil and radar reflectivity overhang, and rightward veering in the storm propagation. In the simulation of the tornadic storm a horseshoe-shaped updraft configuration and cyclic changes in storm intensity and structure were noted. The simulation of the DFW microburst agreed remarkably well with sparse observed data. The simulated outflow rapidly expanded in a nearly symmetrical pattern and was associated with a ringvortex. A South Florida convective complex was simulated and contained updrafts and downdrafts in the form of discrete bubbles. The numerical simulations, in all cases, always remained stable and bounded with no anomalous trends.

Proctor, F. H.↗

Experimental verification of scaling parameters for thermal stratification

A study to determine important dimensionless parameters associated with thermal stratification of a heated container of liquid, and the pressure history of its vapor, was performed. Analysis of the governing equations identified the modified Grashoff number, the modified Fourier number, and the interface number as the dominant dimensionless parameters associated with this process. A test program designed to verify the validity of these scaling parameters was executed. The quality of scaling was checked by comparing the dimensionless pressures and temperatures for scaled pairs of tests. Results indicate that the bulk liquid temperature, the surface temperature of the liquid, and the tank pressure can be scaled with the three dimensionless parameters. Some deviations were found in the detailed temperature profiles between the scaled pairs of tests.

Ji, H.-C.↗

Determination of solid/porous wall boundary conditions from wind tunnel data for computational fluid dynamics codes

A computational and experimental study has been undertaken to investigate methods of modelling solid and porous wall boundary conditions in computational fluid dynamics (CFD) codes. The procedure utilizes experimental measurements at the walls to develop a flow field solution based on the method of singularities. This flow field solution is then imposed as a pressure boundary condition in a CFD simulation of the internal flow field. The effectiveness of this method in describing the boundary conditions at the wind tunnel walls using only sparse experimental measurements has been investigated. Verification of the approach using computational studies has been carried out using an incompressible flow solver. The current work demonstrates this technique for low speed flows and compares the result with experimental data obtained from a heavily instrumented variable porosity test section. Position and refinement of experimental measurements required to describe porous wall boundary conditions have also been considered for application to other porous wall wind tunnels. The approach developed is simple, computationally inexpensive, and does not require extensive or intrusive measurements. It may be applied to both solid and porous wall wind tunnel tests. Some consideration is given to the extension of this method to three dimensions.

Beutner, Thomas J.↗

High-Temperature Gas-Cooled Pebble-Bed Reactors Running In And Transient Modeling Capabilities Demonstration

This study presents a comprehensive benchmarking and verification effort of several thermal-hydraulic and multiphysics capabilities for high-temperature gas-cooled reactor (HTGR) applications. The first part of this effort focuses on the running-in verification of Griffin's multiphysics capabilities, specifically for simulating the evolution of Pebble Bed reactor cores from startup to equilibrium. In the absence of validation data, code-to-code comparisons are conducted with Kugelpy, showing good agreement for key quantities like maximum power density and fresh core k-eigenvalue predictions. However, discrepancies in equilibrium core predictions suggest potential issues with cross sections, underscoring the need for further refinement and evaluation. The HTTF system analysis code benchmark involves RELAP5-3D, SAM, and GAMMA+ to assess their predictive capabilities for HTTF behavior under both normal operation and pressurized conduction cooldown (PCC) transient conditions. While there is good agreement in predicting major parameters such as coolant temperature, solid temperature, and flow distribution, discrepancies in transient behavior highlight differences in modeling approaches, nodalizations, and heat transfer models. The HTTF lower plenum CFD benchmark employs nekRS to simulate flow mixing phenomena, successfully capturing relevant flow physics and demonstrating mesh independence in complex geometries. Preliminary results suggest a relatively uniform temperature field but significant unsteadiness in the flow, requiring time-averaging analyses. The GPBR200 system analysis code benchmark uses SAM's core channel and porous media models, incorporating an RCCS loop for decay heat removal. During steady-state and transient conditions, including protected de-pressurized and pressurized loss of forced cooling (DLOFC and PLOFC), both models show good agreement in predicting temperature profiles and key parameters. Notably, while the core channel model underpredicts convective heat transfer effects, both models maintain temperatures well below the TRISO fuel safety limit. These benchmarking efforts collectively enhance the predictive capabilities of the tools used in HTGR design and safety analysis, guiding developments to improve their accuracy and applicability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analyses to Verify and Improve the Accuracy of the Manufactured Home Energy Audit (MHEA)

A series of analyses were performed to determine the reasons that the Manufactured Home Energy Audit (MHEA) over predicted space-heating energy savings as measured in a recent field test and to develop appropriate corrections to improve its performance. The study used the Home Energy Rating System (HERS) Building Energy Simulation Test (BESTEST) to verify that MHEA accurately calculates the UA-values of mobile home envelope components and space-heating energy loads as compared with other, well-accepted hourly energy simulation programs. The study also used the Procedures for Verification of RESNET Accredited HERS Software Tools to determine that MHEA accurately calculates space-heating energy consumptions for gas furnaces, heat pumps, and electric-resistance furnaces. Even though MHEA's calculations were shown to be correct from an engineering point of view, three modifications to MHEA's algorithms and use of a 0.6 correction factor were incorporated into MHEA to true-up its predicted savings to values measured in a recent field test. A simulated use of the revised version of MHEA in a weatherization program revealed that MHEA would likely still recommend a significant number of cost-effective weatherization measures in mobile homes (including ceiling, floor, and even wall insulation and far fewer storm windows). Based on the findings from this study, it was recommended that a revised version of MHEA with all the changes and modifications outlined in this report should be finalized and made available to the weatherization community as soon as possible, preferably in time for use within the 2009 Program Year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NUMERICAL VERIFICATION OF THE RELAP-7 CORE CHANNEL SINGLE-PHASE MODEL

The RELAP-7 code is the next generation of nuclear reactor system safety analysis code being developed at the Idaho National Laboratory (INL). All the physics in RELAP-7 are fully coupled and the errors resulted from the traditional operator-splitting approach are eliminated. By using 2nd order methods in both time and space and eliminating operator-splitting errors, the numerical error of RELAP-7 can be minimized. Numerical verification is the process to verify the orders of numerical methods. It is an important part of modern verification and validation process. The core channel component in RELAP-7 is designed to simulate coolant flow as well as the conjugated heat transfer between coolant flow and the fuel rod. A special treatment at fuel centerline to avoid numerical singularity for the cylindrical heat conduction in the continuous finite element mesh is discussed. One steady state test case and one fast power up transient test case are utilized for the verification of the core channel model with single-phase flow. Analytical solution for the fuel pin temperature and figures of merit such as peak clad temperature and peak fuel temperature are used to define numerical errors. These cases prove that the mass and energy are well conserved and 2nd order convergence rates for both time and space are achieved in the core channel model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Addendum to SAND2023-09604 Xyce lumped-element transmission line model verification to support Empire-Cable cable SGEMP analyses

This report supplements the Verification of Empire-Cable SAND report by expanding on the use of Xyce to simulate the coupling to a transmission line cable model. While Empire-Cable solves its governing equations on a high-order, finite-element mesh with an an implicit-in-time formulation, Xyce must use a first order graph for the circuit and explicit-in-time approach to be compatible with non-linear electrical device models. Thus, given the different solution methodologies in Xyce as compared to Empire-Cable, the convergence rates are expected to be different but the overall quality of the solution should be the same. The original four canonical problems studied in the Empire-Cable verification report are replicated here running in Xyce using transmission line modeling parameters from the verification report. Overall, agreement between the codes is excellent with Xyce’s convergence rates being limited mostly to first order due to the circuit network approximation of a transmission line being a first order approximation.

42 ENGINEERING↗

Investigation of an implantable dosimeter for single-point water equivalent path length verification in proton therapy

Purpose: In vivo range verification in proton therapy is highly desirable. A recent study suggested that it was feasible to use point dose measurement for in vivo beam range verification in proton therapy, provided that the spread-out Bragg peak dose distribution is delivered in a different and rather unconventional manner. In this work, the authors investigate the possibility of using a commercial implantable dosimeter with wireless reading for this particular application. Methods: The traditional proton treatment technique delivers all the Bragg peaks required for a SOBP field in a single sequence, producing a constant dose plateau across the target volume. As a result, a point dose measurement anywhere in the target volume will produce the same value, thus providing no information regarding the water equivalent path length to the point of measurement. However, the same constant dose distribution can be achieved by splitting the field into a complementary pair of subfields, producing two oppositely ''sloped'' depth-dose distributions, respectively. The ratio between the two distributions can be a sensitive function of depth and measuring this ratio at a point inside the target volume can provide the water equivalent path length to the dosimeter location. Two types of field splits were used in the experiment, one achieved by the technique of beam current modulation and the other by manipulating the location and width of the beam pulse relative to the range modulator track. Eight MOSFET-based implantable dosimeters at four different depths in a water tank were used to measure the dose ratios for these field pairs. A method was developed to correct the effect of the well-known LET dependence of the MOSFET detectors on the depth-dose distributions using the columnar recombination model. The LET-corrected dose ratios were used to derive the water equivalent path lengths to the dosimeter locations to be compared to physical measurements. Results: The implantable dosimeters measured the dose ratios with a reasonable relative uncertainty of 1%-3% at all depths, except when the ratio itself becomes very small. In total, 55% of the individual measurements reproduced the water equivalent path lengths to the dosimeters within 1 mm. For three dosimeters, the difference was consistently less than 1 mm. Half of the standard deviations over the repeated measurements were equal or less than 1 mm. Conclusions: With a single fitting parameter, the LET-correction method worked remarkably well for the MOSFET detectors. The overall results were very encouraging for a potential method of in vivo beam range verification with millimeter accuracy. This is sufficient accuracy to expand range of clinical applications in which the authors could use the distal fall off of the proton depth dose for tight margins.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Remaining Sites Verification Package for the 600-111, P-11 Critical Mass Laboratory Crib, and UPR-600-16, Fire and Contamination Spread Waste Sites, Waste Site Reclassification Form 2004-065

The 600-111, P-11 Critical Mass Laboratory Crib waste site, also referred to as the P-11 Facility, included the 120 Experimental Building, the 123 Control Building, and the P-11 Crib. The facility was constructed in 1949 and was used as a laboratory for plutonium criticality studies. In accordance with this evaluation, the confirmatory and verification sampling results support a reclassification of this site to Interim Closed Out. The results of confirmatory and verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quarterly Report for Dry Storage Safeguards -Q3-2018-LLNL

The objective of this study is to develop a novel methodology for verification of spent fuel inside dry storage casks by analyzing fast/epi-thermal neutrons coming from the top surface of the dry storage casks. In FY2018, data required for MCNP modeling will be gathered, prepared and used to perform MCNP simulations of the system to validate the effectiveness of the verification methodology. Once the methodology is demonstrated to be effective and valid, parameters that affect the detector system sensitivity will be studied as well as the study of diversion scenarios and partial detect.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of motion on jet exhaust noise from aircraft

The various problems involved in the evaluation of the jet noise field prevailing between an observer on the ground and an aircraft in flight in a typical takeoff or landing approach pattern were studied. Areas examined include: (1) literature survey and preliminary investigation, (2) propagation effects, (3) source alteration effects, and (4) investigation of verification techniques. Sixteen problem areas were identified and studied. Six follow-up programs were recommended for further work. The results and the proposed follow-on programs provide a practical general technique for predicting flyover jet noise for conventional jet nozzles.

Chun, K. S.↗