Search NASA⌕ Search

SEARCH · Search NASA

Results for “ablators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

RF Ablation of Giant Hemangiomas Inducing Acute Renal Failure: A Report of Two Cases

ObjectiveIn patients that require treatment for hepatic giant cavernous hemangiomas (GCH), radiofrequency ablation (RFA) has been suggested to represent a safe and effective alternative to invasive surgery. In a recent report of bipolar RFA, using two expandable needle electrodes, was uneventfully performed in patients with large GCH (>10 cm). The objective of this report is to present two cases in which bipolar RFA of symptomatic GCH was complicated by acute kidney injury.Materials and methodsIn 2015 we treated two patients for very large symptomatic GCH (15.7 and 25.0 cm) with bipolar RFA during open laparotomy.ResultsIn both patients the urine showed a red–brown discoloration directly after the ablation. They became anuric and presented with progressive dyspnea, tachypnea, and tachycardia, requiring hemodialysis for a period of 1 month in one case. Lab results revealed hemepigment-induced acute kidney. Both patients fully recovered and both showed a complete relief of symptoms at 3 months following the procedure.ConclusionRFA for large GCHs can cause hemepigment-induced acute kidney injury due to massive intravascular hemolysis. The presented cases suggest that caution is warranted and advocate an upper limit regarding the volume of GCHs that can be safely ablated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiographic Local Tumor Control and Pain Palliation of Sarcoma Metastases within the Musculoskeletal System with Percutaneous Thermal Ablation

PurposeTo evaluate the effectiveness of percutaneous image-guided thermal ablation in achieving local tumor control and pain palliation of sarcoma metastases within the musculoskeletal system.Materials and MethodsRetrospective review of 64 sarcoma metastases within the musculoskeletal system in 26 women and 15 men (total = 41) treated with ablation between December 2011 and August 2016 was performed. Mean age of the cohort was 42.9 years ± 16.0 years. Two subgroups were treated: oligometastatic disease (n = 13) and widely metastatic disease (n = 51). A variety of sarcoma histologies were treated with average tumor volume of 42.5 cm{sup 3} (range 0.1–484.7 cm{sup 3}). Pain scores were recorded before and 4 weeks after therapy for 59% (38/64) of treated lesions. Follow-up imaging was evaluated for local control and to monitor sites of untreated disease as an internal control. Fifty-eight percent (37/64) were lost to imaging follow-up at varying time points over a year. Complication rate was 5% (3/64; one minor and two major events).ResultsOne-year local tumor control rates were 70% (19/27) in all patients, 67% (12/18) in the setting of progression of untreated metastases, and 100% (10/10) in the setting of oligometastatic disease. Median pain scores decreased from 8 (interquartile range 5.0–9.0) to 3 (interquartile range 0.1–4.0) 1 month after the procedure (P < 0.001).ConclusionImage-guided percutaneous ablation is an effective option for local tumor control and pain palliation of metastatic sarcomas within the musculoskeletal system. Treatment in the setting of oligometastatic disease offers potential for remission. Level of Evidence: Level 4, Retrospective Review.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fusion Imaging and Virtual Navigation to Guide Percutaneous Thermal Ablation of Hepatocellular Carcinoma: A Review of the Literature

As medical imaging advancements have improved the detectability of hepatocellular carcinoma (HCC) in early stages, the approach to percutaneous thermal ablation for curative treatment has concomitantly advanced. Although many centers are adopting cross-sectional imaging to guide percutaneous ablation, the majority of procedures are still performed under ultrasound (US) guidance worldwide. Challenges to ultrasound guidance may present due to relatively poor resolution particularly with small or isoechoic lesions, or due to intervening structures such as the bowel or diaphragm that obstruct lesional visualization. Fusion imaging (FI) systems have been employed to address these challenges. By merging or synchronizing the real-time images from US with a previously obtained cross-sectional study, FI mitigates the inherent limitations of each individual imaging modality and expands procedural feasibility and technical outcomes. This manuscript reviews the current literature on the use of FI during percutaneous thermal ablation of HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microwave Ablation of Renal Cell Carcinoma of the Transplanted Kidney: Two Cases

Thermal ablative techniques have been increasingly recognized as a valuable alternative to graftectomy and nephron-sparing surgery for the treatment of small neoplasms arising in the transplanted kidney. However, long-term efficacy and safety data are still lacking. In particular, current experience with microwave ablation is limited to a very recent single-centre series of three cases. We herein report two microwave ablations of renal cell carcinoma of the kidney allograft. The procedures were successfully performed under ultrasound guidance with complete tumour necrosis, no peri-operative complications, and preserved renal function. No recurrences were observed after 3 years of follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Laser Ablation of Liver Metastases from Neuroendocrine Neoplasm. A Retrospective Study for Safety and Effectiveness

Purpose: To retrospectively assess safety and efficacy of laser ablation (LA) of multiple liver metastases (LM) from neuroendocrine neoplasms (NEN). Methods: Twenty-one patients with NEN and at least 3 LM ≤ 4 cm in diameter underwent ultrasonography-guided LA. Up to seven LM were ablated in a single session; if the number of LM exceeded seven, the remaining LM were ablated in further LA sessions with a time interval of 3–4 weeks. LA was performed according to the multifiber technique. The patients underwent contrast-enhanced CT 1 month after LA, and were subsequently monitored every 3 months for the first 2 years and then every 6 months. Results: In total, 189 LM were treated in 21 patients (mean 9 ± 8.2, median 6) in 41 LA sessions (range 1–5). The diameter of LM ranged from 5 to 35 mm (median 19 mm, mean 17.9 ± 6.4 mm). One grade 4 complication occurred (0.53%): a bowel perforation managed by surgery. Technical efficacy was 100%, primary efficacy rate 94.7%, and secondary efficacy rate 100%. Complete relief of hormone-related symptoms was obtained in all the 13 symptomatic patients. Median follow-up was 39 months (range 12–99). 1-, 2-, 3-, and 5-year survival rates were 95%, 86%, 66%, and 40%, respectively. Overall survival resulted higher for patients with Ki-67 expression ≤ 7% than for those with Ki-67 > 7% (p = 0.0347). Conclusions: LA is a promising and safe technique to treat LM from NEN. A longer follow-up should provide definitive information on the long-term efficacy of this liver-directed therapy. Level of Evidence: Retrospective study, local non-random sample, level 3.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Au, Ge and AuGe Nanoparticles Fabricated by Laser Ablation

A eutectic AuGe target immersed in distilled water was ablated by pulsed ultraviolet laser light. The structure of the ablated material was investigated by high-resolution transmission electron microscopy (HRTEM). The images show formation of nanowire structures of AuGe up to 100 nm in length, with widths of 5-10 nm. These nanostructures have Ge content significantly lower than the target material. Electron diffraction demonstrates that they crystallize in the {alpha}-AuGe structure. For comparison, laser ablation of pure Au and pure Ge targets was also performed under the same conditions. HRTEM shows that Ge forms spherical nanoparticles with a characteristic size of {approx}30 nm. Au forms spherical nanoparticles with diameters of {approx}10 nm. Similar to AuGe, it also forms chainlike structures with substantially lower aspect ratio.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Influence of the Solvent on the Structure and Morphology of Nanoparticles Fabricated by Laser Ablation of Bulk Magnesium Targets

Ultrafine powders and colloid solutions of nanoparticles are fabricated by nanosecond pulsed laser ablation (a Nd:YAG laser, 1064 nm, 7 ns, 150 mJ, and 20 Hz) of metallic magnesium targets in water and organic solvents of different polarities (ethyl alcohol, ethyl acetate, and n-hexane). The morphology, dimensional characteristics, composition, and structure of the particles are studied by the methods of transmission electron microscopy, x-ray diffraction, and Fourier-transform infrared spectroscopy depending on the solvent used. For the first time it has been demonstrated that nanostructures of magnesium oxyhydroxide Mg{sub 5}O(OH){sub 8} are formed during the ablation in water. It is established that in organic solvents, formation of hexagonal and cubic magnesium oxides is possible. Nanoparticles fabricated by the ablation in less thermostable solvents – ethyl acetate and hexane – contain carbonates.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Infrared Laser Ablation with Vacuum Capture for Fingermark Sampling

Infrared laser ablation coupled to vacuum capture was employed to collect material from fingermarks deposited on surfaces of different porosity and roughness. Laser ablation at 3 μm was performed in reflection mode with subsequent capture of the ejecta with a filter connected to vacuum. Ablation and capture of standards from fingermarks was demonstrated on glass, plastic, aluminum, and cardboard surfaces. Using matrix assisted laser desorption ionization (MALDI), it was possible to detect caffeine after spiking with amounts as low as 1 ng. MALDI detection of condom lubricants and detection of antibacterial peptides from an antiseptic cream was demonstrated. Detection of explosives from fingermarks left on plastic surfaces as well as from direct deposition on the same surface using gas chromatography mass spectrometry (GC-MS) was shown. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison Between Mass Spectra of Individual Organic Particles Generated by UV Laser Ablation and in the IR/UV Two-Step Mode

One of the most fundamental aspects of single particle mass spectrometry is that the individual particle mass spectra are first classified and only then averaged. When ions are generated by ablation with a UV laser the mass spectra of particles with identical compositions exhibit large particle to particle fluctuations in the mass spectral intensity pattern. This is particularly true when it comes to particles containing organic molecules. At laser fluence that is sufficient to ionize sulfates many of the organic molecules exhibit high degree of fragmentation, often to the point where they cannot be distinguished from elemental carbon. In contrast, when ion generation is separated into two steps, in which the first step uses infra red to evaporate the semi-volatile components and the second, time delayed UV pulse to ionize the evaporating plume, the quality of the individual particle mass spectra are significantly improved. We present an experimental investigation of the properties and behavior of individual particle mass spectra of organic particles that are generated by ablation and in two steps. We investigate the effect of UV laser fluence and the delay between the two lasers. The study shows that the two step approach yields highly reproducible mass spectra that contain sufficient detail to allow clear molecular assignments. The two step approach also produces 10 times as many ions, and the mass spectral intensity can be related to the amount of organics in the particle. In contrast, ablation generated mass spectra were found to exhibit high degree of fragmentation and particle-to-particle fluctuations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser hydrothermal reductive ablation of titanium monoxide: Hydrated TiO particles with modified Ti/O surface

IR laser- and UV laser-induced ablation of titanium monoxide (TM) in hydrogen (50 Torr) is compared to the same process induced in vacuum and shown to result in deposition of hydrated surface modified nanostructured titanium suboxide films. Complementary analyses of the films deposited in vacuum and in hydrogen by Fourier transform infrared, Raman and X-ray photoelectron spectroscopy, X-ray diffraction and electron microscopy allowed to determine different features of both films and propose a mechanism of surface modification of ejected particles, which involves hydrothermal reduction of TM and subsequent reactions of evolved water. The films exert good adhesion to metal and quartz surfaces and are hydrophobic in spite of having their surface coated with adsorbed water. - Graphical abstract: Laser ablation of titanium monoxide (TiO) in hydrogen involves a sequence of H{sub 2} and H{sub 2}O eliminations and additions and yields hydrated amorphous nanostructured titanium suboxide which is richer in oxygen than TiO. Highlights: Black-Right-Pointing-Pointer IR and UV laser ablated particles of titanium monoxide (TiO) undergo amorphization. Black-Right-Pointing-Pointer Films deposited in vacuum have TiO stoichiometry and are oxidized in atmosphere. Black-Right-Pointing-Pointer Films deposited in hydrogen are hydrated and have more O in topmost layers. Black-Right-Pointing-Pointer Films modification in hydrogen is explained by reactions in hydrogen plasma.

36 MATERIALS SCIENCE↗

The TriBeam system: Femtosecond laser ablation in situ SEM

Femtosecond laser ablation offers the unique ability to remove material at rates that are orders of magnitude faster than existing ion beam technologies with little or no associated damage. By combining ultrafast lasers with state-of-the-art electron microscopy equipment, we have developed a TriBeam system capable of targeted, in-situ tomography providing chemical, structural, and topographical information in three dimensions of near mm{sup 3} sized volumes. The origins, development, physics, current uses, and future potential for the TriBeam system are described in this tutorial review. - Graphical abstract: Display Omitted - Highlights: • An emerging tool, the TriBeam, for in situ femtosecond (fs) laser ablation is presented. • Fs laser ablation aided tomography at the mm{sup 3}-scale is demonstrated. • Fs laser induced deposition of Pt is demonstrated at sub-diffraction limit resolution. • Fs laser surface structuring is reviewed as well as micromachining applications.

36 MATERIALS SCIENCE↗

Laser ablation of sub-10 nm silver nanoparticles

Laser ablation of silver nanoparticles (NPs) was studied with laser post-ionization (LPI) time-of-flight mass spectrometry (TOF MS). Silver NPs containing ~15 000 Ag atoms (4 nm radius) were deposited by soft landing (energy 3 eV/atom) onto indium tin oxide (ITO)/glass substrates. Laser ablation was performed using frequency-doubled Ti:sapphire nanosecond pulsed laser irradiation at three different wavelengths (371, 401, and 421 nm), whereas for post-ionization, pulses from an F 2 laser were used. Laser fluences and time delay dependencies of Ag and In signals were obtained. Using these data, the temperature of the desorption source as well as its time duration were calculated. It was found that the peak temperature of NPs was above their melting point and they cooled down slowly, with temperature decay time of several hundreds of nanoseconds. This anomalous behavior was explained based on a model where the semiconducting ITO substrate is initially transparent to the desorption laser radiation but starts to adsorb it due to the temperature increase arising from heat exchange with NPs. Poor heat conduction in the ITO film creates conditions for long-lived hot spots on the surface and initiates further optical damage of the substrate. No difference in the ablation process due to plasmon resonance was detected, likely due to thermal expansion and melting of NPs during laser irradiation, which then broadens the plasmon absorption band enough to cover all wavelengths used. Here, these results clearly demonstrate that the process of NP interaction with laser radiation is governed not only by initial optical and thermophysical parameters of NPs and the surrounding media, but also by their alteration due to temperature increases during the irradiation process.

36 MATERIALS SCIENCE↗

Dynamics of Molecular Emission Features from Nanosecond, Femtosecond Laser and Filament Ablation Plasmas

The evolutionary paths of molecular species and nanoparticles in laser ablation plumes are not well understood due to the complexity of numerous physical processes that occur simultaneously in a transient laser-plasma system. It is well known that the emission features of ions, atoms, molecules and nanoparticles in a laser ablation plume strongly depend on the laser irradiation conditions. In this letter we report the temporal emission features of AlO molecules in plasmas generated using a nanosecond laser, a femtosecond laser and filaments generated from a femtosecond laser. Our results show that, at a fixed laser energy, the persistence of AlO is found to be highest and lowest in ns and filament laser plasmas respectively while molecular species are formed at early times for both ultrashort pulse (fs and filament) generated plasmas. Analysis of the AlO emission band features show that the vibrational temperature of AlO decays rapidly in filament assisted laser ablation plumes.

Laser ablation (LA)↗

Laser ablation of preheated copper samples

A study of the effect of initial sample temperature on laser ablation of a copper sample at ambient air pressure by a 1064 nm, 10 ns laser pulse with energies of 11 and 15 mJ (2.7-3.2 GW/cm{sup 2}) is carried out. The sample is uniformly heated by a heating element up to 600 K. Spectral emission of plasma is measured at different initial sample temperatures and delay times. Plasma temperatures are determined from the method of line pair ratio. The temperature profile inside the preheated target, ablation depth, thickness of dielectric, and melting layer are numerically computed by the finite difference method based on the phase explosion mechanism. Results show that an increase in the initial sample temperature leads to an increase in the spectral emission of plasma up to 90% which is attributed to both the plasma temperature and the ablated volume. Initial sample temperatures have no effects on background intensity of plasma emission. Thus, for spectroscopic purposes, the signal to noise ratio can be improved with initial sample temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact And Robust Laser Impulse Measurement Device, With Ultrashort Pulse Laser Ablation Results

An impulse measurement device and analysis package was conceived, designed, constructed, tested, and demonstrated to be capable of: measuring nanoNewton-seconds to milliNewton-seconds of impulse due to laser-ablation; being transported as carry-on baggage; set-up and tear-down times of less than an hour; target exchange times of less than two minutes (targets can be ablated at multiple positions for thousands of shots); measurements in air and in vacuum; error of just a few percent; repeatability over a wide range of potential systematic error sources; and time between measurements, including ring-down and analysis, of less than 30 seconds. The instrument consists of a cantilever (i.e. leaf spring), whose time-dependent displacement/oscillation is measured and analyzed to determine the impulse imparted by a laser pulse to a target. These shapes are readily/commercially available, and any target material can be used, provided it can be fashioned in the form of a cantilever, or as a coating/film/tape, suitable for mounting on a cantilever of known geometry. The instrument was calibrated both statically and dynamically, and measurements were performed on brass, steel, and Aluminum, using laser pulses of {approx}7 ns, {approx}500 ps, and {approx}500 fs. The results agree well with those published in the literature, with surface effects, atmosphere, and pre-/post-pulses demonstrating interesting effects and indicating areas for further study. These parameters should be carefully controlled and held constant during a series of measurements. The impulse imparted by ablation due to laser filaments in air was also explored.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser induced effects on ZnO targets upon ablation at 266 and 308 nm wavelengths

The development of structural changes in ZnO targets, upon laser irradiation at the wavelengths of 266 and 308 nm, is studied by Raman spectroscopy. At the wavelength of 308 nm, oxygen vacancies are found to develop monotonically with increasing laser intensity. At 266 nm, a structural change in the irradiated ZnO targets, possibly related to nanostructuring, is observed above the laser fluence of 0.45 J cm{sup -2}. The different natures of the laser target interaction processes taking place at both wavelengths are investigated through the characterization of the composition and energy distribution of the species ejected in the ablation. The energy of the neutral Zn and Zn{sub 2} present in the ablation at 308 nm shows a smooth dependence on laser fluence which is consistent with the observed smooth development of oxygen vacancies. At 266 nm, the average kinetic energy of the ejected fragments is higher than at 308 nm and changes abruptly with the ablating laser fluence, consistently with the presence of a fluence threshold above which structural transform is observed at this wavelength. The plume shows the same neutral composition (Zn, ZnO, and Zn{sub 2}) at both wavelengths but the dependence on fluence of the ratio of neutral atomic Zn to the dimer Zn{sub 2} shows significant differences. From the latter, different temperature regimes can be inferred in the plume generated at both wavelengths. At 266 nm the cationic composition of the plume is mainly stoichiometric whereas at 308 nm ZnO{sub 2(3)}H{sub 2(1)}{sup +} cations have the highest intensity.

36 MATERIALS SCIENCE↗

Ablation and plasma emission produced by dual femtosecond laser pulses

Pairs of 80 fs, 800 nm laser pulses were used to ablate Si, Cu, and CaF{sub 2} in air. The spectrally resolved plasma emission was measured as a function of laser fluence and pulse delay. After an initial dip, the fluorescence was found to increase monotonically with pulse delay, reaching a plateau after some tens of picoseconds, depending on the material and fluence. The enhancement ratio (defined as the ratio of the fluorescence produced by the pulse pair to that produced by a single pulse of the same total fluence) reaches a maximum value of 6 and 11 at a fluence of {approx}6 J/cm{sup 2} for Si and Cu, respectively, and declines to a value below 2 at higher fluences. In contrast, the enhancement for CaF{sub 2} increases slowly from zero near threshold to a broad maximum value of 2 near 50 J/cm{sup 2}. Using reflectivity and atomic force microscopy measurements as diagnostics, we interpret the Si and Cu behavior in terms of a two phase mechanism, in which the first pulse melts the surface of the crystal and the second pulse ablates the resulting liquid film. A qualitatively different mechanism initiated by multiphoton absorption is involved in CaF{sub 2} ablation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ablation dominated implosion dynamics of aluminum and stainless steel nested cylindrical wire arrays

The results of experiments with combined aluminum (Al) and stainless steel (SS) alloy 304, nested wire arrays from the 1 MA COBRA generator at Cornell University are presented. The loads studied consisted of a 6 mm diameter inner array and a 13 mm diameter outer array with a different material in each array: SS or aluminum. Al implodes before SS in all loads studied, even when Al was on the inner array. The new wire ablation dynamic model and spectroscopic modeling are used to interpret these data. The observed implosion dynamics are likely a result of the higher ablation rate of Al. These initial results suggest that combining wire materials with different ablation rates in wire array loads could be developed into a useful technique for x-ray pulse shaping and radiation yield optimization.

36 MATERIALS SCIENCE↗