Search NASA⌕ Search

SEARCH · Search NASA

Results for “accurate quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Quantification of water in hydrous ringwoodite

Here, ringwoodite, γ-(Mg,Fe) 2 SiO 4 , in the lower 150 km of Earth’s mantle transition zone (410-660 km depth) can incorporate up to 1.5-2 wt% H 2 O as hydroxyl defects. We present a mineral-specific IR calibration for the absolute water content in hydrous ringwoodite by combining results from Raman spectroscopy, secondary ion mass spectrometery (SIMS) and proton-proton (pp)-scattering on a suite of synthetic Mg- and Fe-bearing hydrous ringwoodites. H 2 O concentrations in the crystals studied here range from 0.46 to 1.7 wt% H 2 O (absolute methods), with the maximum H 2 O in the same sample giving 2.5 wt% by SIMS calibration. Anchoring our spectroscopic results to absolute H-atom concentrations from pp-scattering measurements, we report frequency-dependent integrated IR-absorption coefficients for water in ringwoodite ranging from 78180 to 158880 L mol -1 cm -2 , depending upon frequency of the OH absorption. We further report a linear wavenumber IR calibration for H 2 O quantification in hydrous ringwoodite across the Mg 2 SiO 4 -Fe 2 SiO 4 solid solution, which will lead to more accurate estimations of the water content in both laboratory-grown and naturally occurring ringwoodites. Re-evaluation of the IR spectrum for a natural hydrous ringwoodite inclusion in diamond from the study of the crystal contains 1.43 ± 0.27 wt% H 2 O, thus confirming near-maximum amounts of H 2 O for this sample from the transition zone.

58 GEOSCIENCES↗

Analysis and reduction of chemical models under uncertainty.

While models of combustion processes have been successful in developing engines with improved fuel economy, more costly simulations are required to accurately model pollution chemistry. These simulations will also involve significant parametric uncertainties. Computational singular perturbation (CSP) and polynomial chaos-uncertainty quantification (PC-UQ) can be used to mitigate the additional computational cost of modeling combustion with uncertain parameters. PC-UQ was used to interrogate and analyze the Davis-Skodje model, where the deterministic parameter in the model was replaced with an uncertain parameter. In addition, PC-UQ was combined with CSP to explore how model reduction could be combined with uncertainty quantification to understand how reduced models are affected by parametric uncertainty.

54 ENVIRONMENTAL SCIENCES↗

ROSE: A reduced-order scattering emulator for optical models

A new generation of phenomenological optical potentials requires robust calibration and uncertainty quantification, motivating the use of Bayesian statistical methods. These Bayesian methods usually require calculating observables for thousands or even millions of parameter sets, making fast and accurate emulators highly desirable or even essential. Emulating scattering across different energies or with interactions such as optical potentials is challenging because of the nonaffine parameter dependence, meaning the parameters do not all factorize from individual operators. Here we introduce and demonstrate the reduced-order scattering emulator ( ROSE ) framework, a reduced basis emulator that can handle nonaffine problems. ROSE is fully extensible and works within the publicly available band framework software suite for calibration, model mixing, and experimental design. As a demonstration problem, we use ROSE to calibrate a realistic nucleon-target scattering model through the calculation of elastic cross sections. This problem shows the practical value of the ROSE framework for Bayesian uncertainty quantification with controlled trade-offs between emulator speed and accuracy as compared to high-fidelity solvers. Finally, planned extensions of ROSE are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainty-Aware Machine Learning for Small-Angle X-ray Scattering Analysis in Autonomous Experimentation

Small-angle X-ray scattering (SAXS) is a powerful high-throughput characterization tool for probing nanoscale structure in native sample environments, providing real-time morphological information such as nanoparticle size and shape during synthesis. However, automated SAXS data analysis for extracting meaningful structural parameters is non-trivial and remains a bottleneck in closed-loop experimentation towards autonomous materials discovery, which demands fast, reliable, and uncertainty-aware data analysis. Here, we develop a machine-learning approach for automated SAXS analysis tailored to closed-loop nanoparticle synthesis. A Random Forest (RF) regression model is trained on 100,000 synthetic SAXS curves generated from polydisperse spherical nanoparticles with realistic background contributions. Using normalized one-dimensional SAXS intensity profiles as input, the RF model directly predicts nanoparticle radius, size polydispersity, and background parameters, while the ensemble standard deviation across trees provides built-in uncertainty quantification (UQ). On synthetic data, we show that combining fit-quality metrics (R 2 , MAE) with thresholds on prediction uncertainty reliably identifies accurate parameter estimates without access to ground truth. We then apply the trained model to 365 experimental SAXS profiles of citrate-reduced gold nanoparticles synthesized using an automated droplet-flow microreactor with in situ SAXS at a synchrotron beamline, classifying the results into high- and low-confidence subsets based on UQ metrics. Finally, we integrate RF-based SAXS analysis into a simulated closed-loop optimization campaign using Gaussian process Bayesian optimization to minimize nanoparticle polydispersity, benchmarking against conventional automated Levenberg–Marquardt fitting. The RF-guided campaign exhibits substantially faster convergence and lower relative opportunity cost (∼0.07 vs ∼0.3), demonstrating that uncertainty-aware machine-learning SAXS analysis significantly enhances the efficiency and robustness of autonomous nanomaterials synthesis workflows.

Bayesian optimization↗

Accurate data-driven surrogates of dynamical systems for forward propagation of uncertainty

Stochastic collocation (SC) is a well-known non-intrusive method of constructing surrogate models for uncertainty quantification. In dynamical systems, SC is especially suited for full-field uncertainty propagation that characterizes the distributions of the high-dimensional solution fields of a model with stochastic input parameters. However, due to the highly nonlinear nature of the parameter-to-solution map in even the simplest dynamical systems, the constructed SC surrogates are often inaccurate. Here, this work presents an alternative approach, where we apply the SC approximation over the dynamics of the model, rather than the solution. By combining the data-driven sparse identification of nonlinear dynamics framework with SC, we construct dynamics surrogates and integrate them through time to construct the surrogate solutions. We demonstrate that the SC-over-dynamics framework leads to smaller errors, both in terms of the approximated system trajectories as well as the model state distributions, when compared against full-field SC applied to the solutions directly. We present numerical evidence of this improvement using three test problems: a chaotic ordinary differential equation, and two partial differential equations from solid mechanics.

42 ENGINEERING↗

SU-F-T-362: Quantification and Modelling of the Ionization Chamber Simulation Effective Points On Monaco Treatment Planning System

Purpose: Because of statistical noise in Monte Carlo dose calculations, effective point doses may not be accurate. Volume spheres are useful for evaluating dose in Monte Carlo plans, which have an inherent statistical uncertainty.We use a user-defined sphere volume instead of a point, take sphere sampling around effective point make the dose statistics to decrease the stochastic errors. Methods: Direct dose measurements were made using a 0.125cc Semiflex ion chamber (IC) 31010 isocentrically placed in the center of a homogeneous Cylindric sliced RW3 phantom (PTW, Germany).In the scanned CT phantom series the sensitive volume length of the IC (6.5mm) were delineated and defined the isocenter as the simulation effective points. All beams were simulated in Monaco in accordance to the measured model. In our simulation using 2mm voxels calculation grid spacing and choose calculate dose to medium and request the relative standard deviation ≤0.5%. Taking three different assigned IC over densities (air electron density(ED) as 0.01g/cm3 default CT scanned ED and Esophageal lumen ED 0.21g/cm3) were tested at different sampling sphere radius (2.5, 2, 1.5 and 1 mm) statistics dose were compared with the measured does. Results: The results show that in the Monaco TPS for the IC using Esophageal lumen ED 0.21g/cm3 and sampling sphere radius 1.5mm the statistical value is the best accordance with the measured value, the absolute average percentage deviation is 0.49%. And when the IC using air electron density(ED) as 0.01g/cm3 and default CT scanned EDthe recommented statistical sampling sphere radius is 2.5mm, the percentage deviation are 0.61% and 0.70%, respectivly. Conclusion: In Monaco treatment planning system for the ionization chamber 31010 recommend air cavity using ED 0.21g/cm3 and sampling 1.5mm sphere volume instead of a point dose to decrease the stochastic errors. Funding Support No.C201505006.

60 APPLIED LIFE SCIENCES↗

Quantification of observed flare parameters in relation to a shear-index and verification of MHD models for flare prediction

The goal for the SAMEX magnetograph's optical system is to accurately measure the polarization state of sunlight in a narrow spectral bandwidth over the field of view of an active region to make an accurate determination of the magnetic field in that region. The instrumental polarization is characterized. The optics and coatings were designed to minimize this spurious polarization introduced by foreoptics. The method developed to calculate the instrumental polarization of the SAMEX optics is described.

Wu, S. T.↗

When can we detect lianas from space? Toward a mechanistic understanding of liana‐infested forest optics

Abstract Lianas, woody vines acting as structural parasites of trees, have profound effects on the composition and structure of tropical forests, impacting tree growth, mortality, and forest succession. Remote sensing could offer a powerful tool for quantifying the scale of liana infestation, provided the availability of robust detection methods. We analyze the consistency and global geographic specificity of spectral signals—reflectance across wavelengths—from liana‐infested tree crowns and forest stands, examining the underlying mechanisms of these signals. We compiled a uniquely comprehensive database, including leaf reflectance spectra from 5424 leaves, fine‐scale airborne reflectance data from 999 liana‐infested canopies, and coarse‐scale satellite reflectance data covering 775 ha of liana‐infested forest stands. To unravel the mechanisms of the liana spectral signal, we applied mechanistic radiative transfer models across scales, establishing a synthesis of the relative importance of different mechanisms, which we corroborate with field data on liana leaf chemistry and canopy structure. We find a consistent liana spectral signal at canopy and stand scales across globally distributed sites. This signature mainly arises at the canopy level due to direct effects of more horizontal leaf angles, resulting in a larger projected leaf area, and indirect effects from increased light scattering in the near and short‐wave infrared regions, linked to lianas' less costly leaf construction compared with trees on average. The existence of a consistent global spectral signal for lianas suggests that large‐scale quantification of liana infestation is feasible. However, because the traits responsible for the liana canopy‐reflectance signal are not exclusive to lianas, accurate large‐scale detection requires rigorously validated remote sensing methods. Our models highlight challenges in automated detection, such as potential misidentification due to leaf phenology, tree life history, topography, and climate, especially where the scale of liana infestation is less than a single remote sensing pixel. The observed cross‐site patterns also prompt ecological questions about lianas' adaptive similarities in optical traits across environments, indicating possible convergent evolution due to shared constraints on leaf biochemical and structural traits.

Environmental Sciences & Ecology↗

Cave-based chronology of valley incision in the glaciated Northern Carpathians

While glaciers leave a mark on mountain landscapes, the importance of glacial erosion in mountains at a global scale remains insufficiently constrained despite over a century of research aimed at quantifying the rates and magnitudes of such erosion. Measuring rates of landscape change across the Quaternary in repeatedly glaciated mountain landscapes requires the ability to accurately partition the relative role of glacial versus fluvial processes in forming relief; however, the modification of landforms by surface erosion hinders quantification of process rates over the last few million years. This study presents 32 paired 26 Al and 10 Be cosmogenic nuclide burial ages from allochthonous, quartz-bearing sediment deposited within a paleophreatic karst system in the northern Carpathians. These data quantify Pliocene-to-present timing of valley incision and karst system reactivation, as well as erosion rates over time. Post-burial, muon production-correction yields 24 fully resolved ages, six minimum ages, and two unresolvable ages. Burial ages are interpreted to document the tempo of valley incision via phreatic passage formation and reveal that ∼80% of current valley relief (∼700 m) had developed by approximately 1.6 Ma. Paleoerosion rates derived from this dataset suggest little change in the processes generating sediment washed into the karst networks since the Pliocene. These results suggest that river incision dominated relief creation in Carpathian valleys that bear the imprint of glaciation. Our findings suggest the importance of investigating other mid-latitude mountainous regions worldwide to determine if they have similar erosion and topographic histories.

Carpathians↗

Wave-function-based emulation for nucleon-nucleon scattering in momentum space

Emulators for low-energy nuclear physics can provide fast and accurate predictions of bound-state and scattering observables for applications that require repeated calculations with different parameters, such as Bayesian uncertainty quantification. In this paper, we extend a scattering emulator based on the Kohn variational principle (KVP) to momentum space (including coupled channels) with arbitrary boundary conditions, which enable the mitigation of spurious singularities known as Kohn anomalies. We test it on a modern chiral nucleon-nucleon (N N) interaction, including emulation of the coupled channels. We provide comparisons between a Lippmann-Schwinger equation emulator and our KVP momentum-space emulator for a representative set of neutron-proton (n p) scattering observables, and also introduce a quasi-spline-based approach for the KVP-based emulator. Furthermore, our findings show that while there are some trade-offs between accuracy and speed, all three emulators perform well. Self-contained Jupyter notebooks that generate the results and figures in this paper are publicly available.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fracture Network Quantification for Enhanced Reservoir Characterization in CO2 Storage Sites

Presentation slides on “Fracture Network Quantification for Enhanced Reservoir Characterization in CO2 Storage Sites” for the CCUS 2025 conference held in Houston, Texas March 3-5, 2025. Accurate reservoir characterization is fundamental for the safe and efficient operation of carbon capture, utilization, and storage (CCUS) projects. This process is not only critical during initial site selection but also plays a key role in continuously updating reservoir geomodels throughout injection operations to effectively manage subsurface storage sites. Our primary objective is to develop a comprehensive understanding of fracture networks within CO2 injection reservoirs, which are critical for predicting the behavior of injected fluids, ensuring storage integrity post-injection, and mitigating risks such as leakage or induced seismicity.

artifical intelligence / machine learning (AI/ML)↗

Retrieval of the sea spray aerosol mode from submicron particle size distributions and supermicron scattering during LASIC

Abstract. Improved quantification of sea spray aerosol concentration and size is important for determining aerosol effects on clouds and the climate, though attempts to accurately capture the size distribution of the sea spray mode remain limited by the availability of supermicron size distributions. In this work, we introduce a new approach to retrieving lognormal mode fit parameters for a sea spray aerosol mode by combining submicron size distributions with supermicron scattering measurements using a Mie inversion. Submicron size distributions were measured by an ultra-high-sensitivity aerosol spectrometer (UHSAS), and supermicron scattering was taken as the difference between <10 µm and <1 µm three-wavelength integrating nephelometer measurements (NEPH). This UHSAS-NEPH method was applied during background marine periods of the Department of Energy Atmospheric Radiation Measurement Layered Atlantic Smoke Interactions with Clouds (LASIC) campaign on Ascension Island (November 2016–May 2017), when the contribution of sea spray aerosol was expected to represent a large fraction of the aerosol mass and total scattering. Lognormal sea spray modal parameters were retrieved from comparisons between nephelometer measurements and a lookup table of Mie theory-simulated scattering coefficients for low-error solutions that minimized the 0.4–1 µm residual in the UHSAS size distribution. We evaluated the UHSAS-NEPH method with a set of clean marine measurements in the North Atlantic that included supermicron size and chemical measurements, showing that measured supermicron size distributions are needed to constrain the sea spray number concentration but that mass concentration was reasonably characterized using supermicron scattering. For LASIC, the UHSAS-NEPH method retrieved sea spray mode properties for approximately 88 % of the background marine times when the scattering variability and total particle concentration were low (<± 5 Mm−1 and <400 cm−3, respectively), with mass mean diameter ranging from 0.6 to 1.9 µm (1.47 ± 0.17 µm), modal width ranging from 1.1 to 3.97 (2.4±0.3), and mass concentration ranging from 0.18 to 23.0 µg m−3 (8.37. ± 4.1 µg m−3). The measured nephelometer scattering at three wavelengths was found to constrain the mode width marginally at the largest particle sizes in the absence of additional size and chemical measurements for defining parameters for the Mie solutions. Comparing UHSAS-NEPH retrievals to those of a fitting algorithm applied only to the submicron UHSAS number size distribution showed that correlations between retrieved mass concentration and the available mass-based sea spray tracers (coarse scattering, wind speed, and chloride) are low when supermicron measurements are not considered. This work demonstrates the added value of supermicron scattering measurements for retrieving reasonable sea spray mass concentrations, providing the best-available observationally constrained estimate of the sea spray mode properties when supermicron size distribution measurements are not available.

54 ENVIRONMENTAL SCIENCES↗

A computational methodology for learning low-complexity surrogate models of process from experiments or simulations. (Paper 679a)

Costly and/or insufficiently robust simulations or experiments can often pose difficulties when their use extends well beyond a single evaluation. This is case with the numerous evaluations of uncertainty quantification, when an algebraic model is needed for optimization, as well as numerous other areas. To overcome these difficulties, we generate an accurate set of algebraic surrogate models of disaggregated process blocks of the experiment or simulation. We developed a method that uses derivative-based and derivative-free optimization alongside machine learning and statistical techniques to generate the set of surrogate models using data sampled from experiments or detailed simulations. Our method begins by building a low-complexity surrogate model for each block from an initial sample set. The model is built using a best subset technique that leverages a mixed-integer linear problem formulation to allow for very large initial basis sets. The models are then tested, exploited, and improved through the use of derivative-free solvers to adaptively sample new simulation or experimental points. The sets of surrogate models from each disaggregated process block are then combined with heat and mass balances around each disaggregated block to generate a full algebraic model of the process. The full model can be used for cheap and accurate evaluations of the original simulation or experiment or combined with design specifications and an objective for nonlinear optimization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

TU-A-12A-10: Robust Radiomics Feature Quantification Using Semiautomatic Volumetric Segmentation

Purpose: Recent advances in medical imaging technologies provide opportunities to quantify the tumor phenotype throughout the course of treatment non-invasively. The emerging field of Radiomics addresses this by converting medical images into minable data by applying a large number of quantitative imaging algorithms. Accurate tumor segmentation is one of the main challenges of Radiomics. It has been shown that semiautomatic segmentation approaches efficiently reduce inter-observer variability as compared to the time consuming manual delineations. In this study, a semiautomatic volumetric segmentation algorithm, implemented in the free and publicly available 3D-Slicer platform, was investigated in terms of its robustness for Radiomics features quantification. Methods: Fifty-six 3D-Radiomics features, quantifying phenotypic differences based on the tumor intensity, shape and texture, were extracted from the computed tomography images of twenty lung cancer patients. These Radiomics features were derived from the 3D-tumor volumes defined by three independent observers twice using 3D-Slicer, and compared to manual slice-by-slice delineations of five independent physicians in terms of intra-class correlation coefficient (ICC) and feature range. Results: Radiomics features extracted from 3D-Slicer segmentations had significantly higher reproducibility (ICC= 0.85 0.15, p=0.0009) compared to the features extracted from the manual segmentations (ICC= 0.77 0.17). Furthermore, the features extracted from 3D-Slicer based segmentations, spread over significantly smaller range across observers as compared to those of the manual delineations (p= 3.819e-07). Moreover, the features derived from 3D-Slicer segmentations overlapped in range with those of the manual delineations, as the lower(higher) limit(s) being significantly higher(lower) for the 3D-Slicer features (p= 0.007, p= 5.863e-06). Conclusion: 3D-Slicer based semiautomatic segmentation significantly improves the robustness of radiomics features and thus could serve as a potential alternative to the time consuming manual segmentation process. So 3D-Slicer can have a large application in Radiomics, and be employed for high-throughput data mining research of medical imaging in clinical oncology.

60 APPLIED LIFE SCIENCES↗

Hierarchical Bayesian modeling for Inverse Uncertainty Quantification of system thermal-hydraulics code using critical flow experimental data

The best estimate plus uncertainty methodology in nuclear system thermal-hydraulic studies necessitates a comprehensive understanding of uncertainties in system code predictions. The forward uncertainty quantification (UQ) process involves the propagation of input uncertainties through the computational models to obtain uncertainties in the outputs. To this end, achieving an accurate estimation of input uncertainties is important, which is the focus of inverse UQ (IUQ). Traditionally, research in Bayesian IUQ within the nuclear engineering domain has largely relied on single-level Bayesian inference. While being effective for relatively small datasets, this approach encounters limitations for cases with large datasets. The use of a single-level model may prove inefficient, as the resultant posterior distributions can significantly differ when distinct subsets of data are employed. To address this issue, we employ an hierarchical Bayesian model for IUQ. Furthermore, this approach involves organizing observations into different groups based on the test conditions, thereby accommodating varying calibration parameters across these distinct groups. In this study, we developed and implemented a hierarchical Bayesian IUQ method to consider the grouping effect of critical flow measurement data from various geometries. Comparing the outcomes of IUQ under different selections of test data using hierarchical Bayesian IUQ against those obtained from single-level Bayesian IUQ, the forward propagation of hierarchical Bayesian IUQ results demonstrates a notably improved agreement with the experimental data.

42 ENGINEERING↗

A quantification of errors in surface albedo due to common assumptions

A study comparing the performance of three approaches to estimating the spectral albedo of a typical land surface is presented. The most accurate albedo estimates under all atmospheric situations are those for which the scattering properties of the atmosphere can be used. Simply utilizing the direct-to-total ratio as a weight between direct and Lambertian albedos reduced the errors in broadband albedo to less than one percent for almost all simulated atmospheric conditions.

Arduini, Robert F.↗

WE-A-BRF-01: Dual-Energy CT Imaging in Diagnostic Imaging and Radiation Therapy

The quantification accuracy of dual-energy imaging is influenced by the fundamentals of x-ray physics, system geometry, data acquisition hardware/protocol, system calibration, and image processing technique. This symposium will provide updates on the following advanced application areas: Mammography. Volumetric breast density techniques based on standard mammograms require estimation of breast thickness, which is difficult to accurately measure. By comparison, calculation of breast density using dual energy mammography does not require measurement of breast thickness. Dual energy mammography has been implemented using both energy integrating flat panel detectors in conjunction with beam energy switching and energy resolved photon counting detectors. These techniques have been optimized using simulation studies and validated using physical phantoms and postmortem breasts. Chemical decomposition was used as the gold standard for volumetric breast density measurement in postmortem breasts. Breast density measurements have also been compared with results from four-category BI-RADS density rankings, standard image thresholding and Fuzzy k-mean clustering techniques. These studies indicate that dual energy mammography can be used to accurately measure volumetric breast density. Cardiovascular CT. The predicative accuracy of risk models for recurrent stroke and cardiac arrest depends heavily on accurate differentiation of thrombus or calcium from iodine in left atrial appendage or coronary arteries. The amount of energy separation is constrained by image noise; therefore, optimal kVp, beam filtration, and balanced flux are essential for the quantification accuracy of iodine and calcium. The basis materials are combined linearly to generate monochromatic energy images, where CT# accuracy and CNR are energy dependent. With optimal monochromatic energy, the mean iodine concentration for the thrombus, circulatory stasis, and control groups are significantly different. Risk classification based on calcium scores shows excellent agreement with classification on the basis of conventional coronary artery calcium scoring. These studies demonstrate dual-energy cardiovascular CT can potentially be a noninvasive and sensitive modality in high risk patients. On-board KV/MV Imaging. To enhance soft tissue contrast and reduce metal artifacts, we have developed a dual-energy CBCT technique and a novel on-board kV/MV imaging technique based on hardware available on modern linear accelerators. We have also evaluated the feasibility of these two techniques in various phantom studies. Optimal techniques (energy, beam filtration, # of overlapping projections, etc) have been investigated with unique calibration procedures, which leads to successful decomposition of imaged material into acrylic-aluminum basis material pair. This enables the synthesis of virtual monochromatic (VM) CBCT images that demonstrate much less beam hardening, significantly reduced metal artifacts, and/or higher soft tissue CNR compared to single-energy CBCT. Adaptive Radiation Therapy. DECT could actually contribute to the area of Dose-Guided Radiation Therapy (or Adaptive Therapy). The application of DECT imaging using 80kV and 140 kV combinations could potentially increase the image quality by reducing the bone or high density material artifacts and also increase the soft tissue contrast by a light contrast agent. The result of this higher contrast / quality images is beneficial for deformable image registration / segmentation algorithm to improve its accuracy hence to make adaptive therapy less time consuming in its recontouring process. The real time re-planning prior to per treatment fraction could become more realistic with this improvement especially in hypofractional SBRT cases. Learning Objectives: Learn recent developments of dual-energy imaging in diagnosis and radiation therapy; Understand the unique clinical problem and required quantification accuracy in each application; Understand the different approaches to optimize dual-energy imaging techniques for different applications.

60 APPLIED LIFE SCIENCES↗

Development Strategies for Uncertainty Quantification to Enable Aircraft Certification by Analysis

Aircraft Certification by Analysis (CbA) is a broad term that describes the process by which engineering analysis tools are used to supplement flight testing to demonstrate compliance with regulatory requirements. For each requirement that is to be met through this process, the analysis tools must be sufficiently accurate to ensure that an equivalent level of safety is obtained as if the aircraft to be certified had been flight tested for the requirement. In recent decades, the ability of analysis tools to accurately predict aircraft performance has improved dramatically, leading to increasing interest and limited early adoption of Certification by Analysis across the aerospace industry. However, rigorously demonstrating the credibility of analysis tools remains a challenge for many types of certification requirements, yet is necessary for widespread adoption of CbA approaches in the future. The field of uncertainty quantification is well-suited to address this problem, but will require substantial advances in order to achieve the ambitious industry goals for Certification by Analysis. The objective of this position paper is to highlight gaps in the current technical and programmatic state of uncertainty quantification. Four main categories – Mindset & Awareness, Tools & Capabilities, Data and Benchmarks for V&V, and Applied Research & Established Processes – will be introduced. Each of these categories contains several shortcomings and impediments which, if overcome, will enable more widespread possibilities for Certification by Analysis in the 2040-2050 timeframe.

Uncertainty Quantification↗