Search NASA⌕ Search

SEARCH · Search NASA

Results for “activation temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Development of methodology for optimum design of structures at elevated temperatures

This paper surveys a number of activities aimed at applying optimum design techniques to structures where high temperatures are important design considerations. An improved variant of fully-stressed design (FSD), denoted thermal fully-stressed design (TFSD), is described which converges significantly faster than FSD for problems where thermal stresses are comparable in magnitude to mechanical stresses. Second, an optimality criterion is described for sizing structures subjected to temperature constraints. Simultaneous requirements on strength and temperatures are handled by two different techniques: (1) a state-of-the-art mathematical programming method and (2) the optimality criterion technique for temperature constraints combined with FSD for strength constraints. A method is described to optimize the insulation and ply thicknesses of an insulated composite panel with a time-varying temperature applied to the outer surface of the insulation and a general set of in-plane loads applied to the panel.

Adelman, H. M.↗

An active, stable cubic molybdenum carbide catalyst for the high-temperature reverse water-gas shift reaction

Although technologically promising, the reduction of carbon dioxide (CO 2 ) to produce carbon monoxide (CO) remains economically challenging owing to the lack of an inexpensive, active, highly selective, and stable catalyst. We show that nanocrystalline cubic molybdenum carbide (α-Mo 2 C), prepared through a facile and scalable route, offers 100% selectivity for CO 2 reduction to CO while maintaining its initial equilibrium conversion at high space velocity after more than 500 hours of exposure to harsh reaction conditions at 600°C. The combination of operando and postreaction characterization of the catalyst revealed that its high activity, selectivity, and stability are attributable to crystallographic phase purity, weak CO-Mo 2 C interactions, and interstitial oxygen atoms, respectively. Mechanistic studies and density functional theory (DFT) calculations provided evidence that the reaction proceeds through an H 2 -aided redox mechanism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Response of Venus exospheric temperature measured by neutral mass spectrometer to solar EUV flux measured by Langmuir probe on the Pioneer Venus orbiter

The photoelectron current from the Pioneer Venus Langmuir probe has provided measurements of the total flux of solar EUV photons at Venus since 1979. The neutral oxygen scale height measured by the orbiter neutral mass spectrometer has permitted the exospheric temperature to be derived during the same mission. In this paper, the EUV observations are used to examine the response of exospheric temperature to changes in solar activity, primarily those related to solar rotation. It is found that the dayside exospheric temperature quite faithfully tracks variations in the EUV flux. Comparison is also made with the earth-based solar activity index F10.7 adjusted to the position of Venus. This index varied from 142 to 249 flux units during the period of measurements. The exospheric temperature is better correlated with EUV flux than with the 10.7-cm solar radio flux.

Mahajan, K. K.↗

Solar EUV induced variations in the thermosphere

The effects of solar activity on the thermosphere are reviewed. The neutral total density, temperature, and electron density increase with solar activity, and their variations are fairly well correlated with variations in solar 10.7-cm flux. The electron temperature, by contrast, has a complex behavior with solar activity, depending on altitude and season, as increased heat input is balanced by increased cooling provided by the enhanced electron density. Also, individual neutral species do not all increase in step but are influenced by dissociation and dynamical processes. The increased ion drag at higher solar activities inhibits the neutral wind from increasing in the same proportion as the neutral temperatures and densities.

Hedin, A. E.↗

The theory of an active magnetic regenerative refrigerator

The adiabatic temperature change with field which is limited to about 2 K/Tesla for ferromagnets near their Curie temperatures by the change of magnetization with temperature and the lattice heat capacity is discussed. Practical magnetic refrigerators operate on a regenerative cycle such as the Brayton cycle. This cycle can be executed through the use of an active magnetic regenerator, i.e., a regenerator composed of magnetic material that is cycled in an out of a magnetic field with appropriate fluid flows. The theory of these devices is predicted by solving the partial differential equations that describe fluid and the magnetic solid. The active magnetic regenerator is described along with the method of calculation. Temperature profiles for a normal regenerator and a magnetic regenerative refrigerator are shown.

Barclay, J. A.↗

Design and Testing of an Active Heat Rejection Radiator with Digital Turn-Down Capability

NASA's proposed lunar lander, Altair, will be exposed to vastly different external environment temperatures. The challenges to the active thermal control system (ATCS) are compounded by unfavorable transients in the internal waste heat dissipation profile: the lowest heat load occurs in the coldest environment while peak loads coincide with the warmest environment. The current baseline for this fluid is a 50/50 inhibited propylene glycol/water mixture with a freeze temperature around -35 C. While the overall size of the radiator's heat rejection area is dictated by the worst case hot scenario, a turn-down feature is necessary to tolerate the worst case cold scenario. A radiator with digital turn-down capability is being designed as a robust means to maintain cabin environment and equipment temperatures while minimizing mass and power consumption. It utilizes active valving to isolate and render ineffective any number of parallel flow tubes which span across the ATCS radiator. Several options were assessed in a trade-study to accommodate flow tube isolation and how to deal with the stagnant fluid that would otherwise remain in the tube. Bread-board environmental tests were conducted for options to drain the fluid from a turned-down leg as well an option to allow a leg to freeze/thaw. Each drain option involved a positive displacement gear pump with different methods of providing a pressure head to feed it. Test results showed that a start-up heater used to generate vapor at the tube inlet held the most promise for tube evacuation. Based on these test results and conclusions drawn from the trade-study, a full-scale radiator design is being worked for the Altair mission profile.

Sunada, Eric↗

The influence of temperature on the lubricating effectiveness of MoS2 dispersed in mineral oils

The effects of oil viscosity, base oil temperature, and surface-active agents naturally present in mineral oils on the lubricating effectiveness of MoS2 dispersions under boundary lubrication conditions are investigated. Friction and wear data are obtained from tests conducted under a wide range of oil viscosities and operating temperatures. The dispersion temperature at which the friction dropped below that obtained with the base oils, depended upon the base oil viscosity and the concentration of surface-active agents present in the oil. White oils showed reductions in friction before mineral oils of like viscosity, and lower viscosity oils showed reductions in friction before heavier viscosity oils. The results show that for a given base oil, wear increases as temperature increases, while the wear obtained from a MoS2 dispersion made from the base oil remains approximately constant as temperature is increased.

Rolek, R. J.↗

Dynamical factors affecting ozone mixing ratios in the Antarctic lower stratosphere

An account is given of the climatology and interannual variability of dynamical quantities and ozone mixing ratios during the Southern Hemisphere spring for 1979-1984. The seasonal variation in temperature in the lower stratosphere is repeatable; a steep decrease in zonal mean ozone mixing ratios is observed around 60 deg S toward the South Pole in September which, with time, becomes shallower in association with minor warmings and a final warming. Climatological synoptic charts in the lower stratosphere show the circumpolar circulation in the geopotential height field and the prominence of planetary wave 1 in the temperature and ozone fields. When wave activity is strong, there are weaker westeries, higher temperatures, and higher ozone mixing ratios at high latitudes.

Shiotani, Masato↗

C/sic Life Prediction for Propulsion Applications

Accurate life prediction is critical to successful use of ceramic matrix composites (CMC). The tools to accomplish this are immature and not oriented toward the behavior of carbon fiber reinforced silicon carbide (C/SiC), the primary system of interest for many reusable and single mission launch vehicle propulsion and airframe applications. This paper describes an approach and process made to satisfy the need to develop an integrated life prediction system that addresses mechanical durability and environmental degradation of C/SiC. Issues such as oxidation, steam and hydrogen effects on material behavior are discussed. Preliminary tests indicate that steam will aggressively remove SiC seal coat and matrix in line with past experience. The kinetics of water vapor reaction with carbon fibers is negligible at 600 C, but comparable to air attack at 1200 C. The mitigating effect of steam observed in fiber oxidation studies has also been observed in stress rupture tests. Detailed microscopy of oxidized specimens is being carried out to develop the oxidation model. Carbon oxidation kinetics are reaction controlled at intermediate temperatures and diffusion controlled at high temperatures (approximately 1000 C). Activation energies for T-300 and interface pyrolytic carbon were determined as key inputs to the oxidation model. Crack opening as a function of temperature and stress was calculated. Mechanical property tests to develop and verify the probabilistic life model are very encouraging except for residual strength prediction. Gage width is a key variable governing edge oxidation of seal coated specimens. Future efforts will include architectural effects, enhanced coatings, biaxial tests, and LCF. Modeling will need to account for combined effects.

Levine, Stanley R.↗

C/SIC Life Prediction for Propulsion Applications

Accurate life prediction is critical to successful use of ceramic matrix composites (CMC). The tools to accomplish this are immature and not oriented toward the behavior of carbon fiber reinforced silicon carbide (C/SiC), the primary system of interest for many reusable and single mission launch vehicle propulsion and airframe applications. This paper describes an approach and progress made to satisfy the need to develop an integrated life prediction system that addresses mechanical durability and environmental degradation of C/SiC. Issues such as oxidation, steam and hydrogen effects on material behavior are discussed. Preliminary tests indicate that stream will aggressively remove SiC seal coat and matrix in line with past experience. The kinetics of water vapor reaction with carbon fibers is negligible at 600 C, but comparable to air attack at 1200 C. The mitigating effect of steam observed in fiber oxidation studies has also been observed in stress rupture tests. Detailed microscopy of oxidized specimens is being carried out to develop the oxidation model. Carbon oxidation kinetics are reaction controlled at intermediate temperatures and diffusion controlled at high temperatures (approx. 1000 C). Activation energies for T-300 and interface pyrolytic carbon were determined as key inputs to the oxidation model. Crack opening as a function of temperature and stress was calculated. Mechanical property tests to develop and verify the probabilistic life model are very encouraging except for residual strength prediction. Gage width is a key variable governing edge oxidation of seal coated specimens. Future efforts will include architectural effects, enhanced coatings, biaxial tests, and LCF. Modeling will need to account for combined effects.

Levine, Stanley R.↗

A Detection of the Same Hot Plasma in the Corona: During a CME and Later at Ulysses

We show direct evidence for the same very hot plasma being detected remotely from SOHO in the corona and subsequently, at Ulysses in the solar wind. This is, to our knowledge, the first time that such an unambiguous identification has been made in the case of hot plasma. This detection complements studies correlating other plasma and field properties observed to the properties measured at the source in the corona. This observation takes advantage of a SOHO-Sun-Ulysses quadrature, during which the Sun-Ulysses included angle is $90^\circ$ and it is possible to observe with Ulysses instruments the same plasma that has previously been remotely observed with SOHO instruments in the corona on the limb of the Sun. The identification builds on an existing base of separate SOHO and interplanetary detections of hot plasma. SOHO/UVCS has found evidence for very hot coronal plasma in current sheets in the aftermath of CMEs in the [Fe XVIII] $\lambda$ \AA\ line, implying a temperature on the order of $6\times 10(exp 6)$ K. This temperature is unusually high even for active regions, but is compatible with the high temperature predicted in current sheets. In the solar wind, ACE data from early 1998 to middle 2000 revealed high frozen-in Fe charge state in many cases to be present in interplanetary plasma.

Suess, S. T.↗

EUV analysis of an active region

A sequence of extreme-ultraviolet (EUV) spectroheliograms of McMath region No. 10283 were obtained by OSO-6. The lines O VI (1032 A) Mg X (625 A), Si XII (499 A), and Fe XVI (335 A) were used to determine coronal temperatures and densities above the active region. A comparison of theoretical and observed line ratios yielded coronal temperatures of 2.2 to 2.3 million K above the active region and 2.0 to 2.1 million K in the surrounding area. The temperatures derived from ratios involving the O VI intensities are systematically higher than the others. This is attributed to an error in the theoretical O VI intensities. The intensities observed above the limb are compared with intensities predicted by a simple model based on cylindrical geometry. The overall agreement shows that the assumption of an isothermal corona in hydrostatic equilibrium above the active region is a resonable working hypothesis and that the adopted geometrical model for the electron density distribution is adequate.

Raghavan, N.↗

NADH oxidase activity (NOX) and enlargement of HeLa cells oscillate with two different temperature-compensated period lengths of 22 and 24 minutes corresponding to different NOX forms

NOX proteins are cell surface-associated and growth-related hydroquinone (NADH) oxidases with protein disulfide-thiol interchange activity. A defining characteristic of NOX proteins is that the two enzymatic activities alternate to generate a regular period length of about 24 min. HeLa cells exhibit at least two forms of NOX. One is tumor-associated (tNOX) and is inhibited by putative quinone site inhibitors (e.g., capsaicin or the antitumor sulfonylurea, LY181984). Another is constitutive (CNOX) and refractory to inhibition. The periodic alternation of activities and drug sensitivity of the NADH oxidase activity observed with intact HeLa cells was retained in isolated plasma membranes and with the solubilized and partially purified enzyme. At least two activities were present. One had a period length of 24 min and the other had a period length of 22 min. The lengths of both the 22 and the 24 min periods were temperature compensated (approximately the same when measured at 17, 27 or 37 degrees C) whereas the rate of NADH oxidation approximately doubled with each 10 degrees C rise in temperature. The rate of increase in cell area of HeLa cells when measured by video-enhanced light microscopy also exhibited a complex period of oscillations reflective of both 22 and 24 min period lengths. The findings demonstrate the presence of a novel oscillating NOX activity at the surface of cancer cells with a period length of 22 min in addition to the constitutive NOX of non-cancer cells and tissues with a period length of 24 min.

Non-NASA Center↗

High‐Temperature Mechanical Behavior of Single‐Crystal FeCrAl Alloy Under In Situ Micropillar Compression

FeCrAl cladding is one of the candidate materials for the near‐term accident‐tolerant fuel technologies under development. Research on high‐temperature mechanical behaviors of single‐crystal FeCrAl alloy is rather limited. Previous studies have reported the mechanical property of low‐index orientation in single‐crystal FeCrAl alloy at room temperature. However, the critical resolved shear stress to activate slip systems can be orientation and temperature dependent. Here, single‐crystal grains in a coarse‐grained FeCrAl alloy with different crystallographic orientations are selected to preferentially activate {110}<111> slip systems or {112}<111> slip systems. Micropillars are fabricated in the selected single‐crystal grains and tested at elevated temperatures in situ in a scanning electron microscope. The critical resolved shear stresses of {110}<111> slip systems and {112}<111> slip systems are determined at various temperatures. The critical resolved shear stress shows a temperature dependence and orientation independence. This study provides important insight for understanding the deformation mechanisms of FeCrAl alloys at elevated temperatures.

Sun, Tianyi↗

James Webb Space Telescope Integrated Science Instrument Module Thermal Balance/Thermal Vacuum Test Configuration and Test Planning at NASA's Goddard Space Flight Center

The James Webb Space Telescope (JWST) is the next of the great observatories , scheduled to be launched in 2014. Three of the four science instruments are passively cooled to their operational temperature range of 36K to 40K, and the fourth instrument is actively cooled to its operational temperature of approximately 6K. Thermal-vacuum testing of the flight science instruments at the Integrated Science Instrument Module (ISIM) element level will take place within a newly constructed shroud cooled by gaseous helium inside Goddard Space Flight Center s (GSFC) Space Environment Simulator (SES). The test enclosure surrounding the instruments during the integrated ISIM-level thermal balance testing is complex, and is designed to simulate as closely as possible the in-flight conductive and radiative thermal environment around the ISIM. Thermal control and measurement of parasitic sources of heat leak into the test volume is critical, as the dissipation plus known parasitics in the flight ISIM is approximately 454 mW, and additional parasitics attributed to the flight enclosure itself are nearly equal to this, resulting in the energy balance of the inflight ISIM being less than 1.0 W. Sources of test-induced parasitics must be carefully controlled and measured, and the ability to thermally control the test environment is critical to enable accurate thermal balance testing and thermal model correlation. This paper describes the test configuration and plans for the ISIM-level thermal vacuum/thermal balance testing at GSFC.

Glazer, Stuart↗

James Webb Space Telescope Integrated Science Instrument Module Calibration and Verification of High-Accuracy Instrumentation to Measure Heat Flow in Cryogenic Testing

The James Webb Space Telescope (JWST) is an upcoming flagship observatory mission scheduled to be launched in 2018, Three of the four science instruments are passively cooled to their operational temperature range of 36K to 40K, and the fourth instrument is actively cooled to its operational temperature of approximately 6K. The requirement for multiple thermal zones results in the instruments being thermally connected to five external radiators via individual high purity aluminum heat straps. Thermal-vacuum and thermal balance testing of the flight instruments at the Integrated Science Instrument Module (ISIM) element level will take place within a newly constructed shroud cooled by gaseous helium inside Goddard Space Flight Center's (GSFC) Space Environment Simulator (SES). The flight external radiators are not available during ISIM-Ievel thermal vacuum/thermal testing, so they will be replaced in test with stable and adjustable thermal boundaries with identical physical interfaces to the flight radiators. Those boundaries are provided on specially designed test hardware which measures the heat flow within each of the five heat straps to an accuracy of less than 2 m W, which is less than 5% of the minimum predicted heat flow values. This is essential to ISIM thermal model correlation, since thermal models are more accurately correlated when temperature data is supplemented by accurate knowledge of heat flows. Devices that measure heat flow in this manner have historically been referred to as "Q-meters". Perhaps the most important feature of the design of the Q-meters is that it does not depend on the absolute accuracy of its temperature sensors, but rather on a difference in heater power, for which a table is empirically developed during a calibration campaign in a small chamber at GSFC. This paper discusses the Q-meter calibration procedure including calibration chamber modifications and accommodations, the handling of differing conditions between calibration and usage, the calibration process itself, and the results of the tests used to determine if the calibration is successful.

Comber, Brian↗

James Webb Space Telescope Integrated Science Instrument Module Calibration and Verification of High-Accuracy Instrumentation to Measure Heat Flow in Cryogenic Testing

The James Webb Space Telescope (JWST) is an upcoming flagship observatory mission scheduled to be launched in 2018. Three of the four science instruments are passively cooled to their operational temperature range of 36K to 40K, and the fourth instrument is actively cooled to its operational temperature of approximately 6K. The requirement for multiple thermal zoned results in the instruments being thermally connected to five external radiators via individual high purity aluminum heat straps. Thermal-vacuum and thermal balance testing of the flight instruments at the Integrated Science Instrument Module (ISIM) element level will take place within a newly constructed shroud cooled by gaseous helium inside Goddard Space Flight Center's (GSFC) Space environment Simulator (SES). The flight external radiators are not available during ISIM-level thermal vacuum/thermal testing, so they will be replaced in test with stable and adjustable thermal boundaries with identical physical interfaces to the flight radiators. Those boundaries are provided by specially designed test hardware which also measures the heat flow within each of the five heat straps to an accuracy of less than 2 mW, which is less than 5% of the minimum predicted heat flow values. Measurement of the heat loads to this accuracy is essential to ISIM thermal model correlation, since thermal models are more accurately correlated when temperature data is supplemented by accurate knowledge of heat flows. It also provides direct verification by test of several high-level thermal requirements. Devices that measure heat flow in this manner have historically been referred to a "Q-meters". Perhaps the most important feature of the design of the JWST Q-meters is that it does not depend on the absolute accuracy of its temperature sensors, but rather on knowledge of precise heater power required to maintain a constant temperature difference between sensors on two stages, for which a table is empirically developed during a calibration campaign in a small chamber at GSFC. This paper provides a brief review of Q-meter design, and discusses the Q-meter calibration procedure including calibration chamber modifications and accommodations, handling of differing conditions between calibration and usage, the calibration process itself, and the results of the tests used to determine if the calibration is successful.

Comber, Brian↗