Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Comparison of active interrogation methods for source location in a scattering and absorbing medium, consisting of PGNAA, and an AmBe quasi-forward biased directional source

Source location of Special Nuclear Material (SNM) encompassing 95% 235 U and 239 Pu is identified by utilizing a directional source from Patent No: US20190013109A1 using Prompt Gamma Neutron Activation Analysis (PGNAA) and neutron spectroscopy simulated with Monte-Carlo N-Particle transport 6.2 (MCNP). BC-408, HPGe, LaBr 3 detector arrays were used to identify the location of the SNM using total counts incident on each detector, and PGNAA photopeaks from HPGe and LaBr 3 detector arrays in a polyethylene shield. The conducted simulations varied the volume and location of the SNM in the MCNP input files to observe how the source location method behaved. PGNAA photopeaks used for source identification include 61 keV from fission, 2.223 MeV prompt gamma from hydrogen, 511 keV annihilation, and a single and double escape peaks from the prompt gamma interaction from hydrogen. The capabilities of each detector systems to acquire well resolved photopeaks with a 1% relative error or less, and total relative error for F4 and F8 tallies were less than 0.015% relative error. Source predictions of the SNM with uneven amounts of polyethylene shielding between the source and detectors was observed to overpredict and give invalid source location predictions. Source locations of the SNM with even amounts of polyethylene material between the source and each detector were found to be valid. With a 1 Ci 241 Am source activity, it was determined that 1630 s were needed to obtain the results for each detector system with the quasi-forward directional AmBe source. Coupling source and material identification together would increase acquisition time but would only require one system to determine.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computed Tomography of Dry Cask Storage for Used Fuel

The demand for dry cask storage for used nuclear fuel is on the rise due to the continuous operation of currently existing nuclear plants which are reaching or have reached the capacity of their used fuel pools. Dry cask storage allows used fuel that has already been cooled in the used fuel pool for at least five years to be surrounded by an inert gas inside a specially designed and licensed cask. Currently, 75 of the 78 U.S.A reactor sites either have or are pursuing an independent spent fuel storage installation (ISFSI) for dry cask fuel storage [1] with over 2,000 casks already loaded [2]. Cask loading will only continue to increase until a final repository solution is operational or the U.S. begins to recycle fuel. The challenge of monitoring the condition of the used fuel inside the cask without exposing the used fuel has been apparent since the 1980s. The objective of the University of Florida (UF) project is ultimately to investigate the feasibility of imaging the used fuel assemblies’ location and evaluating the inner structural condition using emission source computed tomography (CT). A combination of radiation transport models will be used to simulate gamma-rays and neutrons traversing through the used fuel, structure, and cask body materials. In the simulations, multiple linear detector arrays will record the radiation outside the cask wall and will be placed at various angles in order to model rotating a linear detector array around the entire cask. The combination of data from all the detectors will give the planar radiation projection onto the detectors, more commonly called the Radon transform, of the structure of used fuel assemblies. This project can be processed with filtered back projection or other more advanced reconstructive imaging algorithms to recreate the fuel structures. A majority of the historical work done for used fuel has been on verification, diversion detection, and burnup credit validation in order to meet regulatory guidelines. One of the more commonly used systems for single assembly verification is the Fork Detector developed at Los Alamos National Laboratory in 1988 [3]. A group at the Idaho National Laboratory developed a Compton Dry-Cask Imaging Scanner that has the ability to detect empty vs full storage positions but it suffered a setback when transported to the Doel Nuclear Power Plant near Antwerp, Belgium; the system was unable to detect full energy peaks because of the additional scattering caused by a thick ballistic steel shield [4]. As detectors, computational power, and modeling improves, a few groups have leveraged these advancements and started to investigate CT hoping, that despite the difficulties, the technique can give information on fuel condition. So far the groups have mostly limited the tomographic work to a per assembly basis [5] [6] [7], rather than the full dry cask as the University of Florida plans to investigate. The downsides of CT versus simpler verification and validation are the amount of data required and the time it takes to acquire that data. Given that dry casks are intended to sit undistributed for up to 60 years, a scanning time of several weeks to several months is not unreasonable if such systems do not require human operators beyond the initial setup.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computed Tomography of Dry Cask Storage for Used Fuel

The demand for dry cask storage for used nuclear fuel is on the rise due to the continuous operation of currently existing nuclear plants which are reaching or have reached the capacity of their used fuel pools. Dry cask storage allows used fuel that has already been cooled in the used fuel pool for at least five years to be surrounded by an inert gas inside a specially designed and licensed cask. Currently, 75 of the 78 U.S.A reactor sites either have or are pursuing an independent spent fuel storage installation (ISFSI) for dry cask fuel storage with over 2,000 casks already loaded. Cask loading will only continue to increase until a final repository solution is operational or the U.S. begins to recycle fuel. The challenge of monitoring the condition of the used fuel inside the cask without exposing the used fuel has been apparent since the 1980's. The objective of the University of Florida (UF) project is ultimately to investigate the feasibility of imaging the used fuel assemblies' location and evaluating the inner structural condition using emission source computed tomography (CT). A combination of radiation transport models will be used to simulate gamma-rays and neutrons traversing through the used fuel, structure, and cask body materials. In the simulations, multiple linear detector arrays will record the radiation outside the cask wall and will be placed at various angles in order to model rotating a linear detector array around the entire cask. The combination of data from all the detectors will give the planar radiation projection onto the detectors, more commonly called the Radon transform, of the structure of used fuel assemblies. This project can be processed with filtered back projection or other more advanced reconstructive imaging algorithms to recreate the fuel structures. A majority of the historical work done for used fuel has been on verification, diversion detection, and burnup credit validation in order to meet regulatory guidelines. One of the more commonly used systems for single assembly verification is the Fork Detector developed at Los Alamos National Laboratory in 1988. A group at the Idaho National Laboratory developed a Compton Dry-Cask Imaging Scanner that has the ability to detect empty vs full storage positions but it suffered a setback when transported to the Doel Nuclear Power Plant near Antwerp, Belgium; the system was unable to detect full energy peaks because of the additional scattering caused by a thick ballistic steel shield. As detectors, computational power, and modeling improves, a few groups have leveraged these advancements and started to investigate CT hoping, that despite the difficulties, the technique can give information on fuel condition. So far the groups have mostly limited the tomographic work to a per assembly basis , rather than the full dry cask as the University of Florida plans to investigate. The downsides of CT versus simpler verification and validation are the amount of data required and the time it takes to acquire that data. Given that dry casks are intended to sit undistributed for up to 60 years, a scanning time of several weeks to several months is not unreasonable if such systems do not require human operators beyond the initial setup. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dosimetric validation of a commercial Monte Carlo based IMRT planning system

Purpose: Recently a commercial Monte Carlo based IMRT planning system (Monaco version 1.0.0) was released. In this study the dosimetric accuracy of this new planning system was validated. Methods: Absolute dose profiles, depth dose curves, and output factors calculated by Monaco were compared with measurements in a water phantom. Different static on-axis and off-axis fields were tested at various source-skin distances for 6, 10, and 18 MV photon beams. Four clinical IMRT plans were evaluated in a water phantom using a linear diode detector array and another six IMRT plans for different tumor sites in solid water using a 2D detector array. In order to evaluate the accuracy of the dose engine near tissue inhomogeneities absolute dose distributions were measured with Gafchromic EBT film in an inhomogeneous slab phantom. For an end-to-end test a four-field IMRT plan was applied to an anthropomorphic lung phantom with a simulated tumor peripherally located in the right lung. Gafchromic EBT film, placed in and around the tumor area, was used to evaluate the dose distribution. Results: Generally, the measured and the calculated dose distributions agreed within 2% dose difference or 2 mm distance-to-agreement. But mainly at interfaces with bone, some larger dose differences could be observed. Conclusions: Based on the results of this study, the authors concluded that the dosimetric accuracy of Monaco is adequate for clinical introduction.

61 RADIATION PROTECTION AND DOSIMETRY↗

High spectral resolution airborne spectrometry

An airborne spectroradiometer system developed at Columbia University has been providing new spectral data for use in remote sensing for natural resources. The system has been improved by addition of a solid state silicon detector array, and has been extended into the infrared by addition of a 64 element lead sulfide detector array. The infrared data in the 2000 to 2500 nm region especially holds large potential for mineral and oil exploration.

Collins, W.↗

JWST Near-Infrared Detector Degradation: Finding the Problem, Fixing the Problem, and Moving Forward

The James Webb Space Telescope (JWST) is the successor to the Hubble Space Telescope. JWST will be an infrared optimized telescope, with an approximately 6.5 m diameter primary mirror, that is located at the Sun-Earth L2 Lagrange point. Three of JWST's four science instruments use Teledyne HgCdTe HAWAII-2RG (H2RG) near infrared detector arrays. During 2010, the JWST Project noticed that a few of its 5 micron cutoff H2RG detectors were degrading during room temperature storage, and NASA chartered a "Detector Degradation Failure Review Board" (DD-FRB) to investigate. The DD-FRB determined that the root cause was a design flaw that allowed indium to interdiffuse with the gold contacts and migrate into the HgCdTe detector layer. Fortunately, Teledyne already had an improved design that eliminated this degradation mechanism. During early 2012, the improved H2RG design was qualified for flight and JWST began making additional H2RGs. In this article we present the two public DD-FRB "Executiye Summaries" that: (1) determined the root cause of the detector degradation and (2) defined tests to determine whether the existing detectors are qualified for flight. We supplement these with a brief introduction to H2RG detector arrays, and a discussion of how the JWST Project is using cryogenic storage to retard the degradation rate of the existing flight spare H2RGs.

Rauscher, Bernard J.↗

Overview of the Optical Communications Demonstrator

The Optical Communications Demonstrator is a laboratory-based lasercom demonstration instrument designed to validate effective beacon acquisition, high bandwidth tracking, precision beam pointing, and point ahead compensation functions. The instrument is designed using an array detector for both spatial acquisition and high bandwidth tracking, and a fiber coupled laser transmitter. The array detector tracking concept provides wide field of view acquisition as well as high update rate using a single output channel device. At the same time, it permits effective platform jitter compensation and point ahead control using only one steering mirror. The use of fiber coupled transmitter further modularizes transmitter design and de-couples the thermal management problem. The reduction in design complexity can lead to a reduced system cost and an improved system reliability. Furthermore, it can permit the implementation of a new generation of lasercom instruments capable of realizing the inherent advantages of optical frequency communication systems.

laser↗

Optical beam forming techniques for phased array antennas

Conventional phased array antennas using waveguide or coax for signal distribution are impractical for large scale implementation on satellites or spacecraft because they exhibit prohibitively large system size, heavy weight, high attenuation loss, limited bandwidth, sensitivity to electromagnetic interference (EMI) temperature drifts and phase instability. However, optical beam forming systems are smaller, lighter, and more flexible. Three optical beam forming techniques are identified as applicable to large spaceborne phased array antennas. They are (1) the optical fiber replacement of conventional RF phased array distribution and control components, (2) spatial beam forming, and (3) optical beam splitting with integrated quasi-optical components. The optical fiber replacement and the spatial beam forming approaches were pursued by many organizations. Two new optical beam forming architectures are presented. Both architectures involve monolithic integration of the antenna radiating elements with quasi-optical grid detector arrays. The advantages of the grid detector array in the optical process are the higher power handling capability and the dynamic range. One architecture involves a modified version of the original spatial beam forming approach. The basic difference is the spatial light modulator (SLM) device for controlling the aperture field distribution. The original liquid crystal light valve SLM is replaced by an optical shuffling SLM, which was demonstrated for the 'smart pixel' technology. The advantages are the capability of generating the agile beams of a phased array antenna and to provide simultaneous transmit and receive functions. The second architecture considered is the optical beam splitting approach. This architecture involves an alternative amplitude control for each antenna element with an optical beam power divider comprised of mirrors and beam splitters. It also implements the quasi-optical grid phase shifter for phase control and grid amplifier for RF power. The advantages are no SLM is required for this approach, and the complete antenna system is capable of full monolithic integration.

Wu, Te-Kao↗

Characterization and Design of Digital Pointing Subsystem for Optical Communication Demonstrator

The Optical Communications Demonstrator (OCD) is a laboratory-based lasercom demonstration terminal designed to validate several key technologies, including beacon acquisition, high bandwidth tracking, precision bearn pointing, and point-ahead compensation functions. It has been under active development over the past few years. The instrument uses a CCD array detector for both spatial acquisition and high-bandwidth tracking, and a fiber coupled laser transmitter. The array detector tracking concept provides wide field-of-view acquisition and permits effective platform jitter compensation and point-ahead control using only one steering mirror. This paper describes the detailed design and characterization of the digital control loop system which includes the Fast Steering Mirror (FSM), the CCD image tracker, and the associated electronics. The objective is to improve the overall system performance using laboratory measured data. The. design of the digital control loop is based on a linear time invariant open loop model. The closed loop performance is predicted using the theoretical model. With the digital filter programmed into the OCD control software, data is collected to verify the predictions. This paper presents the results of the, system modeling and performance analysis. It has been shown that measurement data closely matches theoretical predictions. An important part of the laser communication experiment is the ability of FSM to track the laser beacon within the. required tolerances. The pointing must be maintained to an accuracy that is much smaller than the transmit signal beamwidth. For an earth orbit distance, the system must be able to track the receiving station to within a few microradians. The failure. to do so will result in a severely degraded system performance.

Racho, C.↗

ISO Key Project: Exploring the full range of QUASAR/AGN properties

The PIA (PHOT Interactive Analysis) software was upgraded as new releases were made available by VILSPA. We have continued to analyze our data but, given the large number of still outstanding problems with the calibration and analysis (listed below), we remain unable to move forward on our scientific program. We have concentrated on observations with long (256 sec) exposure times to avoid the most extreme detector responsivity drift problems which occur with a change in observed flux level, ie. as one begins to observe a new target. There remain a significant number of problems with analyzing these data including: (1) the default calibration source (FCS) observations early in the mission were too short and affected by strong detector responsivity drifts; (2) the calibration of the FCS sources is not yet well-understood, particularly for chopped observations (which includes most of ours); (3) the detector responsivity drift is not well-understood and models are only now becoming available for fitting chopped data; (4) charged particle hits on the detector cause transient responsivity drifts which need to be corrected; (5) the "flat-field" calibration of the long-wavelength (array) detectors: C1OO, C200 leaves significant residual structure and so needs to be improved;(6) the vignetting correction, which affects detected flux levels in the array detectors, is not yet available; (7) the intra-filter calibrations are not yet available; and (8) the background above 60 microns has a significant gradient which results in spurious positive and negative "detections" in chopped observations. ISO Observation planning, conferences and talks, ground based observing and other grant related activities are also briefly discussed.

Wilkes, B.↗

Design and validation of a cold load for characterization of cosmic microwave background stage 4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by cosmic microwave background stage 4 (CMB-S4), the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three innovative design features: (1) the ability to operate from the 1-K stage of a dilution refrigerator (DR), (2) a He3 gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150-GHz detector array previously deployed by the Spider experiment. Thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1-K stage. In addition, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mosaic Infrared Sensor for Space Astronomy (MIRSSA)

The development of mosaic infrared detector/focal plane arrays for space astronomy is reported. The Mosaic IR Sensor for Space Astronomy (MIRSSA) Program is an effort to develop PV HgCdTe detector arrays with the spectral response of up to 5 micron and silicon CCDs for low temperature applications. Desired background-limited performance (BLIP) for space applications requires an extremely high R sub A product which can be achieved by selecting the detector materials and the operating temperature. The parameters were determined by measurement of HgCdTe PV detector arrays at various temperatures in the SW and MW spectral bands. It is demonstrated that high performance PV HgCdTe detectors can be fabricated for low temperature applications.

Source record↗

Long-wave infrared (LWIR) detectors based on III-V materials

Future NASA missions for earth observation and planetary science require large photovoltaic detector arrays with high performance in the long wavelength region to 18 microns and at operating temperatures above 65 K where single-cycle long-life cryocoolers are being developed. Since these detector array requirements exceed the state of current HgCdTe technology, alternative detector materials are being investigated as a possible option for future missions. Advanced growth techniques (e.g., MBE and MOCVD) of column III-V semiconductors have opened opportunities for engineering new detector materials and device structures. The technical approaches under investigation at JPL (with university and industry participation) include: quantum well infrared photodetectors, heterojunction internal photoemission (HIP) photodetectors, type-II strained layer superlattices, and nipi doping superlattices. Each of these options are briefly described with some of their pros and cons. A more detailed description is given for the HIP approach being pioneered at JPL.

Maserjian, Joseph↗

Star sensing for an earth imaging sensor

A star sensor includes (a) a scan mirror for scanning at least one star; (b) a detector array, coupled to the scan mirror, for detecting the one star; and (c) a processor, coupled to the detector array. The processor includes a first filter configured to reduce noise spikes in the detected one star, and provide a detection mask of filtered data. Also included is a second filter configured to reduce non-contiguous samples in the detection mask. A centroid calculator is included to determine a location of the one star, after the first and second filtering. The first filter includes a median filter, followed by an averaging filter, both configured to filter the one star in an along-scan direction of the scan mirror. The first filter includes another median filter, which is configured to filter the detected one star in the cross-scan direction of the scan mirror. An adder is included to subtract (a) output data from the other median filter from (b) output data from the averaging filter and provide filtered star data to the second filter.

Ellis, Kenneth K.↗

Combining {gamma}-ray and particle spectroscopy in Cologne

To gain additional information on nuclear structure, the new silicon-detector array SONIC, consisting of up to eight {Delta}E-E telescopes, was installed inside the existing HPGe-detector array HORUS in Cologne. Its main purpose is the study of inelastic scattering using p-, d- and {alpha}-beams of a 10 MV Tandem accelerator. The array has already been tested with two experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The New Maia Detector System: Methods For High Definition Trace Element Imaging Of Natural Material

Motivated by the need for megapixel high definition trace element imaging to capture intricate detail in natural material, together with faster acquisition and improved counting statistics in elemental imaging, a large energy-dispersive detector array called Maia has been developed by CSIRO and BNL for SXRF imaging on the XFM beamline at the Australian Synchrotron. A 96 detector prototype demonstrated the capacity of the system for real-time deconvolution of complex spectral data using an embedded implementation of the Dynamic Analysis method and acquiring highly detailed images up to 77 M pixels spanning large areas of complex mineral sample sections.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fuel Cycle Research & Development Technical Monthly – May 2012

Management and Integration LANL - Initial coordination meetings with NE and NA-20 were held the first week of May. Additional meetings, to include NA-82 and the new Proliferation and Terrorism Risk Assessment task are scheduled for June. Work package planning as part of the NTD transition is ongoing. Microcalorimetry LANL - Some parts to attempt repair of a malfunctioning water chiller that has been holding up work on the current detector array have arrived. We will attempt to begin running the compressor/cryostat next week to resume work on commissioning the detector array. We have also been working on a backup plan to temporarily move our system to a different lab space. Completed data analysis and prepared a paper summarizing Pu measurements for peer-review journal. Two members of our team presented work at the SORMA West 2012 conference. Completed data analysis and prepared a milestone report summarizing the development of Monte Carlo tools to study systematic errors. Electrochemical Sensor INL - The second sensor test was stopped short due to the work stand-down. Some activities related to this work have resumed, but not all. The sensor used during the second test was removed from the furnace and it showed cracks and later crumbled when being rinsed for sample preparation. The sensor material will be submitted to SEM analysis once work is resumed in the facilities where analysis is performed. A third sensor test has started. Tests with different arrangements will continue and will be oriented based on post-test analysis of the first three sensor tests. Materials with different annealing temperatures will also be prepared for analysis. Lead slowing down spectrometer LANL - Continued work on perturbation method for LSDS analysis. We are running simulations to delineate issues and are checking additional data libraries to see whether there are differences in simulation results. Electrochemical sensor INL - The second sensor test was stopped short due to the work stand-down. Some activities related to this work have resumed, but not all. The sensor used during the second test was removed from the furnace and it showed cracks and later crumbled when being rinsed for sample preparation. The sensor material will be submitted to SEM analysis once work is resumed in the facilities where analysis is performed. A third sensor test has started. Tests with different arrangements will continue and will be oriented based on post-test analysis of the first three sensor tests. Materials with different annealing temperatures will also be prepared for analysis. Fast Neutron Multiplicity analysis INL - The University of Michigan team continues its work on the post-experiment analysis of the validation data from JRC ISPRA, as well as scoping studies using the simulation tool MCNPX-PoliMi. At INL, our new staff member working on this project is now working to model performance capabilities for the fast-neutrons scintillator design concepts. At INL our primary analysis approach is focused on the Feynman mean-to-variance approach. At the University of Michigan, the primary analysis approach is multiplicity coincidence analysis. Fast Neutron Imaging to Quantify Nuclear Materials ORNL - Completed additional measurements of the two 'trainer' configurations as well as calibration measurements with sources on an x-y stage. The imager was shipped to Pantex for an NA-22 obligation at the end of May. Lead Slowing Down Spectrometer LANL - Continued to look into He4 detector. A Swiss company was located that makes He4 detectors and associated electronics. Had a teleconference with them to assess the possible help we can get from them. We are also looking in to constructing one locally. Ongoing perturbation calculations are providing information on the fundamental systematic error limits of LSDS. In order to achieve separating the contribution of Pu and 235U to the signal, there will need to be tight controls on systematic errors. Multi-isotope Process Monitor PNNL - Attended a training call in advanced multivariate classification and analysis methods. These methods were applied to the multivariate analysis of fuel characteristics based on simulated gamma. Work continued on a computational framework to quantify the impact of gamma-ray counting statistical precision on principal component regression (PCR) analysis of a multi-component (i.e. multi-isotope) gammaray spectrum. Tests of the simulation framework are anticipated to begin in early June. Development of a proposal to instrument H-Canyon is being prepared in conjunction with SRNL and the NNSA's NGSI program is ongoing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calibration of a novel four-dimensional diode array

Purpose: The aim of this work is to develop effective calibration methods for a novel four-dimensional (4D) diode array for pretreatment verification of intensity-modulated radiation therapy (IMRT) and rotational therapy. Methods: A novel 4D diode array (ArcCHECK, Sun Nuclear, Melbourne, FL) was developed to meet the needs of appropriate and efficient quality assurance for IMRT and especially rotational radiotherapy. The diode array presents a consistent detector image in beam's eye view at arbitrary gantry angles due to isotropic arrangement of diodes in a three-dimensional (3D) cylindrical phantom. The 50 ms simultaneous update of all diodes on the detector array (fourth dimension) makes it capable of time-resolved beam delivery analysis with any rotational delivery techniques. The calibration procedure consisted of delivering and measuring a series of calibration beams with 5.8 deg. angular spacing surrounding the cylindrical diode array. Correction factors for diode intrinsic sensitivity and directional response dependence were derived from these measurements. A real-time algorithm to derive gantry angles based on the detector signal was developed to interpolate and apply the corresponding angular correction factors. Results: The calibration was validated with ion chamber scanned beam profiles in a 3D water tank. Excellent agreement was observed between diode array measurement and treatment planning system calculation. The accuracy of the gantry angle derivation algorithm was within 1 deg. which caused a less than 0.2% dosimetric uncertainty. Conclusions: With the proposed calibration method and the automatic gantry angle derivation algorithm, the 4D diode array achieved isotropic detector response and is suitable for both IMRT and rotational therapy pretreatment verification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗