Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

The charge and energy spectra of heavy cosmic ray nuclei

A charged particle detector array flown in a high altitude balloon detected and measured some 30,000 cosmic ray nuclei with Z greater than or equal to 12. The charge spectrum at the top of the atmosphere for nuclei with E greater than 650 MeV/n and the energy spectrum for 650 less than or equal to E less than 1800 MeV/n are reported and compared with previously published results. The charge spectrum at the source of cosmic rays is deduced from these data and compared with a recent compilation of galactic abundances.

Scarlett, W. R.↗

Infrared Astronomical Satellite

The objective of the Infrared Astronomical Satellite is to produce an unbiased all-sky survey in the wavelength region between 8 and 120 microns. Using a 60 cm diameter helium cooled telescope and detector arrays which are essentially zodiacal light background photon noise limited, heretofore unprecedented sensitivity can be achieved. The optical design, the focal plane layout and expected performance of the current design concept are discussed.

Aumann, H. H.↗

Optical design of a stigmatic spectroheliometer for photometric studies of dynamic phenomena at extreme-ultraviolet wavelengths

The design of a stigmatic spectroheliometer for photometric studies of dynamic phenomena in the solar atmosphere at extreme ultraviolet (EUV) wavelengths is described. The normal-incidence spectrometer requires only one reflective surface, and is equipped with a series of exit slits and associated one-dimensional detector arrays that are mounted at the secondary (vertical) foci of the concave diffraction grating. It is shown that such a spectrometer mounted at the focus of an off-axis paraboloid telescope mirror of the size employed in the EUV spectroheliometer flown on Skylab could record monochromatic images of a 2 x 2 (arcmin) sq field-of-view with a spatial resolution element of 1 x 1 (arcsec) sq in a time of 4 s, 24 s, or 4 min, depending on whether the region studied is flaring, active, or quiet. The resulting spectroheliograms would have an average photometric precision of 10% and a spectral purity of 0.1 A.

Huber, M. C. E.↗

New limits on gamma-ray bursts

Two balloon flights of large-area scintillation crystal detector arrays indicate that the rate of weak gamma-ray bursts is significantly below that expected from a uniform distribution of burst sources. This result, combined with the data from stronger bursts, gives strong evidence for a galactic confinement of burst sources. Reasonable models of confinement limit the intrinsic radiated energy per burst to the order of 10 to the (39th to 41st power) ergs.

Fishman, G. J.↗

The charge and energy spectra of heavy cosmic-ray nuclei

A charged-particle detector array flown on a high-altitude balloon has detected and measured some 30,000 cosmic-ray nuclei with Z of at least 12. The charge spectrum at the top of the atmosphere for nuclei with energies greater than 650 MeV/n and the energy spectrum for energies between 650 and 1800 MeV/n are reported and compared with previously published results. The charge spectrum at the 'source' of cosmic rays is deduced from these data and compared with a recent compilation of 'galactic' abundances.

Scarlett, W. R.↗

DUMAND Summer Workshop, University of California, La Jolla, Calif., July 24-September 2, 1978, Proceedings. Volume 3 - Oceanographic and ocean engineering studies

The DUMAND (Deep Underwater Muon and Neutrino Detector) array, a hexagon 800 m on a side, 673 m high, and consisting of 22,698 sensor modules, is designed to detect neutrinos in the TeV range, hadronic cascades, muons and Cerenkov radiation. Its engineering, signal processing, and logistic aspects are considered, as are its optical detection (photomultiplier tubes) system and electronics. Geological and bottom current surveys were made at two proposed sites for the array (the Maui and Keahole Point basins of Hawaii), and a study of the steady-state response of a sensor string to current drag forces is reported. Biological interference with the DUMAND array, including mechanical entanglement by large animals, bioluminescence, and especially biofouling are considered, as well as the deployment, implantment and maintenance of the array.

Wilkins, G.↗

Multi-anode microchannel arrays

The Multi-Anode Microchannel Arrays (MAMA's) are a family of photoelectric, photon-counting array detectors being developed for use in instruments on both ground-based and space-borne telescopes. These detectors combine high sensitivity and photometric stability with a high-resolution imaging capability. MAMA detectors can be operated in a windowless configuration at extreme-ultraviolet and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. Prototype MAMA detectors with up to 512 x 512 pixels are now being tested in the laboratory and telescope operation of a simple (10 x 10)-pixel visible-light detector has been initiated. The construction and modes-of-operation of the MAMA detectors are briefly described and performance data are presented.

Timothy, J. G.↗

Large volume multiple path nuclear lasing of /He-3/-Ar

Output power of 550 W has been achieved from a nuclear-pumped multiple path laser system containing (He-3)-Ar by using the (He-3)(n, p)3(H) nuclear reaction for power deposition. Lasing was achieved in Ar at 1790 nm. The complex beam profile was resolved by an InAs array detector. Laser output was directly proportional to thermal neutron flux, and also increased proportionally with increasing (He-3) pressure up to 292.6 kPa. The variation of the laser output power with the number of passes through the excited medium was found to peak at 5-7 passes.

De Young, R. J.↗

Development of a fast ion mass spectrometer for space research

An ion mass spectrometer having a cylindrical E bar x B bar analyzer and either a cylindrical or spherical electrostatic analyzer is described. The instrument has two nested channels and a postacceleration between the electrostatic and E bar x B bar analyzers for wide ranges of energy and mass responses. It is noted that the dual-channel construction not only doubles the data acquisition rate but also permits a reversal of the electrostatic field orientation in the inner channel for lighter ions. The outer channel is then optimized for ions of medium to high mass numbers, resulting in increased mass resolution for such heavy ions. When combined with a cylindrical E bar x B bar analyzer, a 90-deg-deflection angle spherical electrostatic analyzer provides an extremely wide viewing angle. The angular distribution of ions can be derived from such geometry if a position-sensitive resistive anode or a detector array is used at the exit aperture. Details on the principles of operation, the instrument design, and calibration are presented.

Hahn, S. F.↗

Raman scattering as a probe of planetary atmospheres

The observable effects of Raman scattering on the spectra of the giant planets may provide new information on the composition and structure of these atmospheres. Satellite observations have already shown the influence of Raman scattering on the UV continuum albedo. A cross correlation technique is presented for detecting rotational and vibrational transitions of the Raman active gases in the atmosphere. This technique has been applied to ground-based visible spectra of Venus, Jupiter, Saturn and Uranus. Extension of this method into the UV would improve the detectability of the Raman lines because the ratio of Raman to Rayleigh cross section increases with decreasing wavelength. The technology currently exists to efficiently obtain high-signal-to-noise ratio UV spectra through the use of silicon diode array detectors. Application of the cross-correlation technique to UV spectra obtained from space vehicles would give a new important probe of the structure and composition of planetary atmospheres by enabling the use of the UV spectra of a planet to observe what would normally be an infrared molecular transition.

Cochran, W. D.↗

Near-infrared spectral imaging Michelson interferometer for astronomical applications

The design and operation of an imaging Michelson interferometer-spectrometer used for near-infrared (0.8 micron to 2.5 microns) spectral imaging are reported. The system employs a rapid scan interferometer modified for stable low resolution (250/cm) performance and a 42 element PbS linear detector array. A microcomputer system is described which provides data acquisition, coadding, and Fourier transformation for near real-time presentation of the spectra of all 42 scene elements. The electronic and mechanical designs are discussed and telescope performance data presented.

Wells, C. W.↗

Remote sensing of oceanic phytoplankton - Present capabilities and future goals

A description is given of current work in the development of sensors, and their integration into increasingly powerful systems, for oceanic phytoplankton abundance estimation. Among the problems relevant to such work are phytoplankton ecology, the spatial and temporal domains, available sensor platforms, and sensor combinations. Among the platforms considered are satellites, aircraft, tethered balloons, helicopters, ships, and the Space Shuttle. Sensors discussed include microwave radiometers, laser fluorosensors, microwave scatterometers, multispectral scanners, Coastal Ocean Dynamics Radar (CODAR), and linear array detectors. Consideration is also given to the prospects for such future sensor systems as the National Oceanic Satellite System (NOSS) and the Airborne Integrated Mapping System (AIMS).

Esaias, W. E.↗

Raman scattering in the Jovian atmosphere

On December 8 and 9, 1976, the 1024 channel Reticon silicon photodiode array detector in the coude spectrograph of a 2.7 m telescope was used to obtain spectra of Jupiter and the moon. Three separate data sets were obtained, including one of the Jovian equatorial region, one of the Jovian north polar cap, and one of Mare Serenetatis on the moon. A correlation analysis was conducted. The autocorrelation function of the Jovian spectrum was calculated and the autocorrelation function of the lunar spectrum was subtracted from it. The analysis made it possible to detect Raman scattering by H2 in the atmosphere of Jupiter. The pure rotational H2 S(0) and S(1) lines were detected. The ratio of the relative number of Raman scattered photons in the S(0) and S(1) features indicate that the H2 in the Jovian atmosphere is in the equilibrium, rather than the normal state. Therefore some sort of nonradiative process is responsible for transitions between the ortho and para states of H2.

Cochran, W. D.↗

Germanium accumulation-mode charge-injection-device process

Gallium doped germanium is suitable for applications in the detection of far infrared radiation. Measurements were made on experimental photoconductors (PCs), accumulation mode charge injection devices (AMCIDs), and the SSPC (a switched, sampled PC alternative to the AMCID). The results indicate that the SSPC, which had a responsivity near 1.5 amp/watt, is desirable for use in two dimensional detector arrays.

Moore, T. G.↗

Transverse velocity measurement

Carbon dioxide (CO2) laser Doppler lidar systems are employed in the remote measurement of wind velocities. The cross velocity component is measured utilizing an appropriate detector array configuration. This allows determination of the three dimensional characteristics of the wind with conventional Doppler lidar systems.

Source record↗

A concept for a future ground control data set for image correction

Strips of ground control can be established with current and future satellite sensors. These can provide precise and reliable geometric references for locating and correcting satellite image data and to support temporal image registration. This paper briefly describes the concept and approach for implementing this data base called a Ground Control Strip, and recommends additional work. The advent of new solid state imaging systems, in particular the linear array detectors (pushbroom sensors), make this new concept particularly attractive and practical.

Bernstein, R.↗

A search for diffuse band profile variations in the rho Ophiuchi cloud

High signal-to-noise profiles of the broad diffuse interstellar band at 4430 A were obtained on the 2.2-m telescope at the Mauna Kea Observatory, using the newly-developed pulse-counting multi-anode microchannel array detector system in an effort to determine whether the band profile varies with mean grain size as expected if the band is produced by absorbers embedded in grain lattices. The lack of profile variability over several lines of sight where independent evidence indicates that the mean grain size varies shows that lambda 4430 is probably not formed by the same grains that are responsible for interstellar extinction at visible wavelengths. The possibility that this band is created by a population of very small ( approximately 100 A) grains is still viable, as is the hypothesis that it has a molecular origin.

Snow, T. P.↗

Extended range X-ray telescope: X-ray microscope design

A glancing incidence X-ray microscope using a confocal hyperboloid ellipsoid mirror was designed to couple optically a Wolter 1 telescope to a CCD focal plane detector. Both the RMS spot size and the point spread function calculations were used to evaluate the resolution, defocusing, and vignetting effects of the system for microscope focal lengths of 1, 1.5, and 2 meters and for magnifications varying from 2 to 10x. For the specific application with the S-056 telescope, a 2 meter, 8x microscope with a fabrication ratio of the microscope mirror length to the inner diameter at hyperboloid ellipsoid intersection of 2.5 was designed to be used with a thinned, back illuminated CCD detector array with 320 by 512, 30 micron pixels.

Shealy, D. L.↗