Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Monte Carlo simulation of the dose response of a novel 2D silicon diode array for use in hybrid MRI–LINAC systems

Purpose: MRI-guided radiation therapy systems (MRIgRT) are being developed to improve online imaging during treatment delivery. At present, the operation of single point dosimeters and an ionization chamber array have been characterized in such systems. This work investigates a novel 2D diode array, named “magic plate,” for both single point calibration and 2D positional performance, the latter being a key element of modern radiotherapy techniques that will be delivered by these systems. Methods: GEANT4 Monte Carlo methods have been employed to study the dose response of a silicon diode array to 6 MV photon beams, in the presence of in-line and perpendicularly aligned uniform magnetic fields. The array consists of 121 silicon diodes (dimensions 1.5 × 1.5 × 0.38 mm{sup 3}) embedded in kapton substrate with 1 cm pitch, spanning a 10 × 10 cm{sup 2} area in total. A geometrically identical, water equivalent volume was simulated concurrently for comparison. The dose response of the silicon diode array was assessed for various photon beam field shapes and sizes, including an IMRT field, at 1 T. The dose response was further investigated at larger magnetic field strengths (1.5 and 3 T) for a 4 × 4 cm{sup 2} photon field size. Results: The magic plate diode array shows excellent correspondence (< ± 1%) to water dose in the in-line orientation, for all beam arrangements and magnetic field strengths investigated. The perpendicular orientation, however, exhibits a dose shift with respect to water at the high-dose-gradient beam edge of jaw-defined fields [maximum (4.3 ± 0.8)% over-response, maximum (1.8 ± 0.8)% under-response on opposing side for 1 T, uncertainty 1σ]. The trend is not evident in areas with in-field dose gradients typical of IMRT dose maps. Conclusions: A novel 121 pixel silicon diode array detector has been characterized by Monte Carlo simulation for its performance inside magnetic fields representative of current prototype and proposed MRI–linear accelerator systems. In the in-line orientation, the silicon dose is directly proportional to the water dose. In the perpendicular orientation, there is a shift in dose response relative to water in the highest dose gradient regions, at the edge of jaw-defined and single-segment MLC fields. The trend was not observed in-field for an IMRT beam. The array is expected to be a valuable tool in MRIgRT dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

New scintillator materials for future and present facilities

In the recent years LaBr3:Ce crystals started a new generation of high performing scintillator detectors. In fact, a large number of different, new and promising scintillators are now becoming commercially available, as for example CeBr{sub 3}, CLYC, SrI{sub 2}. Some others, like GYGAG:Ce, CLLB, CLLC, will be available in the near future. The CLYC crystal enriched with {sup 6}Li provides extremely high efficiency for thermal neutron identification and detection with performances comparable to {sup 3}He tubes. The CLYC enriched with {sup 7}Li can provide the direct measurement of the neutron kinetic energy from the energy pulse signal. The most recent R and D activity shows that ‘co-doping’ technique has the effect to improve the crystal proportionality and the mechanical properties thus significantly increasing the reliability and energy resolution of LaBr{sub 3};Ce and CeBr{sub 3} scintillators. Such a new generation of detectors can be the backbone for the detectors array of the future accelerator facilities as for example ELI-NP which will provide very intense high-energy γ-ray beam with very low bandwidth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum ghost imaging microscopy depth-of-field study

Quantum ghost imaging approaches have been proposed to enhance biological microscopy, for example, using 2D visible detectors to provide IR images or providing additional dimensions of spatial or spectral information. Toward the goal of making such imaging schemes practical, we compare image quality and depth-of-field between traditional images and ghost images at the same excitation levels. We measure how image quality and depth-of-field depend on the parameters of the entangled light produced using type-I spontaneous parametric down-conversion (SPDC). We use a pair of time-synchronized, photon-timing single-photon avalanche diode (SPAD) array detectors to capture two distinct microscope imaging paths simultaneously on a photon-pair-by-photon-pair basis: one in a traditional imaging pathway and the other a quantum ghost imaging pathway. We calculate the depth-of-field, resolution, contrast, and signal-to-noise ratio (SNR) through the parameter space of a β-Barium Borate (BBO) type-I bulk non-linear crystal length and angle. Our results provide a basis for choosing parameters for quantum ghost imaging with type-I SPDC sources.

47 OTHER INSTRUMENTATION↗

SU-F-T-289: MLC Fluence Sonogram Based Delivery Quality Assurance for Bilateral Breast Irradiation

Purpose: Performing DQA for Bilateral (B-L) breast tomotherapy is a challenging task due to the limitation of any commercially available detector array or film. Aim of this study is to perform DQA for B-L breast tomotherapy plan using MLC fluence sinogram. Methods: Treatment plan was generated on Tomotherapy system for B-L breast tumour. B-L breast targets were given 50.4 Gy prescribed over 28 fractions. Plan is generated with 6 MV photon beam & pitch was set to 0.3. As the width of the total target is 39 cm (left & right) length is 20 cm. DQA plan delivered without any phantom on the mega voltage computed tomography (MCVT) detector system. The pulses recorded by MVCT system were exported to the delivery analysis software (Tomotherapy Inc.) for reconstruction. The detector signals are reconstructed to a sonogram and converted to MLC fluence sonogram. The MLC fluence sinogram compared with the planned fluence sinogram. Also point dose measured with cheese phantom and ionization chamber to verify the absolute dose component Results: Planned fluence sinogram and reconstructed MLC fluence sinogram were compared using Gamma metric. MLC positional difference and intensity of the beamlet were used as parameters to evaluate gamma. 3 mm positional difference and 3% beamlet intensity difference were used set for gamma calculation. A total of 26784 non-zero beamlets were included in the analysis out of which 161 beamlets had gamma more than 1. The gamma passing rate found to be 99.4%. Point dose measurements were within 1.3% of the calculated dose. Conclusion: MLC fluence sinogram based delivery quality assurance performed for bilateral breast irradiation. This would be a suitable alternate for large volume targets like bilateral breast, Total body irradiation etc. However conventional method of DQA should be used to validate this method periodically.

60 APPLIED LIFE SCIENCES↗

3D DVH-based metric analysis versus per-beam planar analysis in IMRT pretreatment verification

Purpose: To evaluate methods of pretreatment IMRT analysis, using real measurements performed with a commercial 2D detector array, for clinical relevance and accuracy by comparing clinical DVH parameters. Methods: We divided the work into two parts. The first part consisted of six in-phantom tests aimed to study the sensitivity of the different analysis methods. Beam fluences, 3D dose distribution, and DVH of an unaltered original plan were compared to those of the delivered plan, in which an error had been intentionally introduced. The second part consisted of comparing gamma analysis with DVH metrics for 17 patient plans from various sites. Beam fluences were measured with the MapCHECK 2 detector, per-beam planar analysis was performed with the MapCHECK software, and 3D gamma analysis and the DVH evaluation were performed using 3DVH software. Results: In a per-beam gamma analysis some of the tests yielded false positives or false negatives. However, the 3DVH software correctly described the DVH of the plan which included the error. The measured DVH from the plan with controlled error agreed with the planned DVH within 2% dose or 2% volume. We also found that a gamma criterion of 3%/3 mm was too lax to detect some of the forced errors. Global analysis masked some problems, while local analysis magnified irrelevant errors at low doses. Small hotspots were missed for all metrics due to the spatial resolution of the detector panel. DVH analysis for patient plans revealed small differences between treatment plan calculations and 3DVH results, with the exception of very small volume structures such as the eyes and the lenses. Target coverage (D{sub 98} and D{sub 95}) of the measured plan was systematically lower than that predicted by the treatment planning system, while other DVH characteristics varied depending on the parameter and organ. Conclusions: We found no correlation between the gamma index and the clinical impact of a discrepancy for any of the gamma index evaluation possibilities (global, local, 2D, or 3D). Some of the tests yielded false positives or false negatives in a per-beam gamma analysis. However, they were correctly accounted for in a DVH analysis. We also showed that 3DVH software is reliable for our tests, and is a viable method for correlating planar discrepancies with clinical relevance by comparing the measured DVH of target and OAR's with clinical tolerance.

60 APPLIED LIFE SCIENCES↗

Design and performance of the spin asymmetries of the nucleon experiment

The Spin Asymmetries of the Nucleon Experiment (SANE) performed inclusive, double-polarized electron scattering measurements of the proton at the Continuous Electron Beam Facility at Jefferson Lab. A novel detector array observed scattered electrons of four-momentum transfer 2.5 < Q 2 < 6.5 GeV 2 and Bjorken scaling 0.3 < x < 0.8 from initial beam energies of 4.7 and 5.9 GeV. Employing a polarized proton target which could be rotated with respect to the incident electron beam, both parallel and near perpendicular spin asymmetries were measured, allowing model-independent access to transverse polarization observables A 1 , A 2 , g 1 , g 2 and moment d 2 of the proton. This article summarizes the operation and performance of the polarized target, polarized electron beam, and novel detector systems used during the course of the experiment, and describes analysis techniques utilized to access the physics observables of interest.

43 PARTICLE ACCELERATORS↗

A multichannel time-of-flight system for observation of energetic ions of multispecies generated from relativistic laser plasma

A multichannel time-of-flight (TOF) system was constructed to observe the ions generated from relativistic laser plasma, where the ions have polychromatic energies and multiple species. The TOF system is composed of a ten-channel scintillation detector array and an electromagnet that generates a magnetic field of 0-1.24 T. The magnet field enables us to analyze protons, deuterons, and full-stripped carbon ions to 50, 25, and 150 MeV, respectively. The system experimentally identified protons of 0.27-1.6 MeV energy and ions of a half specific charge (deuterons of 0.3-0.8 MeV and full-stripped carbons of 1.8-4.8 MeV). The measured TOF values agree well with the calculated values within the designed accuracy; {+-}2.5 ns for protons and {+-}5 ns for the others (d or C{sup 6+}) on each detector channel. Comparison of ion numbers detected by a track detector (CR-39) and the TOF system enabled us to obtain the number of ions detected on each scintillation counter with less than 16% error.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GERDA phase II detectors: Behind the production and characterisation at low background conditions

The low background GERmanium Detector Array (GERDA) at Laboratori Nazionali del Gran Sasso (LNGS) is designed to search for the rare neutrinoless double beta decay (0νββ) in {sup 76}Ge. Bare germanium diodes are operated in liquid argon which is used as coolant, as passive and soon active as well shield against external radiation. Currently, Phase I of the experiment is running using ∼15 kg of co-axial High Purity Germanium diodes. In order to increase the sensitivity of the experiment 30 Broad Energy Germanium (BEGe) diodes will be added within 2013. This presentation reviews the production chain of the new BEGe detectors from isotopic enrichment to diode production and testing. As demonstrated all steps were carefully planned in order to minimize the exposure of the enriched germanium to cosmic radiation. Following this premise, acceptance and characterisation measurement of the newly produced diodes have been performed within the HEROICA project in the Belgian underground laboratory HADES close to the diode manufacturer. The test program and the results from a subset of the recently terminated GERDA Phase II BEGe survey will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthetic aperture microwave imaging with active probing for fusion plasma diagnostics

A Synthetic Aperture Microwave Imaging (SAMI) system has been designed and built to obtain 2-D images at several frequencies from fusion plasmas. SAMI uses a phased array of linearly polarised antennas. The array configuration has been optimised to achieve maximum synthetic aperture beam efficiency. The signals received by antennas are down-converted to the intermediate frequency range and then recorded in a full vector form. Full vector signals allow beam focusing and image reconstruction in both real time and a post-processing mode. SAMI can scan over 16 pre-programmed frequencies in the range of 10-35GHz with a switching time of 300ns. The system operates in 2 different modes simultaneously: both a 'passive' imaging of plasma emission and also an 'active' imaging of the back-scattered signal of the radiation launched by one of the antennas from the same array. This second mode is similar to so-called Doppler backscattering (DBS) reflectometry with 2-D resolution of the propagation velocity of turbulent structures. Both modes of operation show good performance in fusion plasma experiments on Mega Amp Spherical Tokamak (MAST). We have obtained the first ever 2-D images of BXO mode conversion windows. With active probing, first ever turbulence velocity maps have been obtained. We present an overview of the diagnostic and discuss recent results. In contrast to quasi-optical microwave imaging systems SAMI requires neither big aperture viewing ports nor large 2-D detector arrays to achieve the desired imaging resolution. The number of effective 'pixels' of the synthesized image is proportional to the number of receiving antennas squared. Thus only a small number of optimised antennas is sufficient for the majority of applications. Possible implementation of SAMI on ITERand DEMO is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of standardized data formats and tools for ground-level particle-based gamma-ray observatories

Context. Ground-based γ-ray astronomy is still a rather young field of research, with strong historical connections to particle physics. This is why most observations are conducted by experiments with proprietary data and analysis software, as is usual in the particle physics field. However, in recent years, this paradigm has been slowly shifting toward the development and use of open-source data formats and tools, driven by upcoming observatories such as the Cherenkov Telescope Array (CTA). In this context, a community-driven, shared data format (the gamma-astro-data-format, or GADF) and analysis tools such as Gammapy and ctools have been developed. So far, these efforts have been led by the Imaging Atmospheric Cherenkov Telescope community, leaving out other types of ground-based γ-ray instruments. Aims. We aim to show that the data from ground particle arrays, such as the High-Altitude Water Cherenkov (HAWC) observatory, are also compatible with the GADF and can thus be fully analyzed using the related tools, in this case, Gammapy. Methods. We reproduced several published HAWC results using Gammapy and data products compliant with GADF standard. We also illustrate the capabilities of the shared format and tools by producing a joint fit of the Crab spectrum including data from six different γ-ray experiments. Results. We find excellent agreement with the reference results, a powerful confirmation of both the published results and the tools involved. Conclusions. The data from particle detector arrays such as the HAWC observatory can be adapted to the GADF and thus analyzed with Gammapy. A common data format and shared analysis tools allow multi-instrument joint analysis and effective data sharing. To emphasize this, a sample of Crab nebula event lists is made public with this paper. Because of the complementary nature of pointing and wide-field instruments, this synergy will be distinctly beneficial for the joint scientific exploitation of future observatories such as the Southern Wide-field Gamma-ray Observatory and CTA.

79 ASTRONOMY AND ASTROPHYSICS↗

Real-time multi-mode neutron multiplicity counter

Embodiments are directed to a digital data acquisition method that collects data regarding nuclear fission at high rates and performs real-time preprocessing of large volumes of data into directly useable forms for use in a system that performs non-destructive assaying of nuclear material and assemblies for mass and multiplication of special nuclear material (SNM). Pulses from a multi-detector array are fed in parallel to individual inputs that are tied to individual bits in a digital word. Data is collected by loading a word at the individual bit level in parallel, to reduce the latency associated with current shift-register systems. The word is read at regular intervals, all bits simultaneously, with no manipulation. The word is passed to a number of storage locations for subsequent processing, thereby removing the front-end problem of pulse pileup. The word is used simultaneously in several internal processing schemes that assemble the data in a number of more directly useable forms. The detector includes a multi-mode counter that executes a number of different count algorithms in parallel to determine different attributes of the count data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The polarization sensitivity of GRETINA

Compton polarimeters have played an important role in the study of nuclear structure physics, but have often been limited in their applications because of relatively low -ray detection efficiency. With the advent of -ray tracking detector arrays, which feature nearly solid angle coverage and the ability to identify the location of Compton-scattering events to within a few millimeters, this limitation can be overcome. Here we present a characterization of the performance of the Gamma Ray Energy Tracking In-beam Nuclear Array (GRETINA) as a Compton polarimeter using the 24 Mg(p,p') reaction at 2.45 MeV proton energy. We also discuss a new capability added to the simulation package UCGretina to simulate the emission of polarized photons, and compare it to the measured data. Lastly, we use these simulations to predict the performance of the Gamma Ray Energy Tracking Array (GRETA).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

BEAMING NEUTRINOS AND ANTI-NEUTRINOS ACROSS THE EARTH TO DISENTANGLE NEUTRINO MIXING PARAMETERS

A result from MINOS seemed to indicate that the mass splitting and mixing angle of anti-neutrinos is different from that of neutrinos, suggesting a charge-parity-time (CPT) violation in the lepton sector. However, more recent MINOS data reduced the {nu}{sub {mu}}-{nu}-bar{sub {mu}} differences leading to a narrow discrepancy nearly compatible with no CPT violation. However, the last few years of OPERA activity on the appearance of a tau lepton (one unique event) still has not been probed and more tools may be required to disentangle a list of parameters ({mu}-{tau} flavor mixing, tau appearance, any eventual CPT violation, {theta}{sub 13} angle value, and any hierarchy neutrino mass). Atmospheric anisotropy in muon neutrino spectra in the DeepCore, at ten to tens of GeV (unpublished), can hardly reveal asymmetry in the eventual {nu}{sub {mu}}-{nu}-bar{sub {mu}} oscillation parameters. Here we considered how the longest baseline neutrino oscillation available, crossing most of Earth's diameter, may improve the measurement and at best disentangle any hypothetical CPT violation occurring between the earliest (2010) and the present (2012) MINOS bounds (with 6{sigma} a year), while testing {tau} and even the appearance of {tau}-bar at the highest rate. The {nu}{sub {mu}} and {nu}-bar{sub {mu}} disappearance correlated with the tau appearance is considered for those events at the largest distances. We thus propose a beam of {nu}{sub {mu}} and {nu}-bar{sub {mu}} crossing through the Earth, within an OPERA-like experiment from CERN (or Fermilab), in the direction of the IceCube-DeepCore {nu} detector at the South Pole. The ideal energy lies at 21 GeV to test the disappearance or (for any tiny CPT violation) the partial {nu}-bar{sub {mu}} appearance. Such a tuned detection experiment may lead to a strong signature of {tau} or {tau}-bar generation even within its neutral current noise background events: nearly one {tau}-bar or two {tau} a day. The tau appearance signal is above (or within) 10{sigma} a year, even for a 1% OPERA-like experiment. Peculiar configurations for {theta}{sub 13} and the hierarchy neutrino mass test may also be better addressed by a DeepCore-PINGU array detector beaming {nu}{sub {mu}} and observing {nu}{sub e} at 6 GeV neutrino energy windows.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Environmental Characterization Scans Using Sodium-Iodide Gamma Spectroscopy to Determine Ra-226 Concentration in Surface Soil - 16326

The recent natural gas drilling boom has brought heightened attention to the issue of TENORM waste management. Radioactive residues from the extraction, treatment, and purification of materials containing uranium and thorium, or their progeny, pose a public health hazard primarily in the form of ground water contamination. Hydraulic fracturing can liberate formation waters from shale; the high salinity of which can cause radium to move with the water to the surface. The disposal and handling of this water has been a subject of public controversy. For soil remediation projects, radium-226 is generally one of the radionuclides of concern due to its alpha emissions. However performing a survey scan for Ra-226 is difficult because its photon emissions are low energy and have minimal probability of emission per decay (186.2 keV, 3.3% abundance). Additionally resolving its emission from U-235 (185.7 keV, 57% abundance) with field instrumentation is not feasible. Therefore detection of Ra-226 relies on the presence and photon emissions of its progeny. This paper outlines methodology for calculating the minimum detectable concentration of Ra-226 in characterization scans using a sodium-iodide detector array coupled with a multi-channel analyzer. Using progeny ingrowth as a detection proxy requires knowing decay time in order to determine progeny emission rates. Knowledge of site history, process, and prior survey results can be key in determining an accurate decay time. However in the absence of such information in-situ measurements can be used to estimate decay time by comparing observed progeny emission ratios against established values. These values are determined using Oak Ridge National Laboratory's ORIGEN-ARP program to generate photon energy spectra for Ra-226 and its progeny at specified time intervals. Once decay time is established, the detector's minimum detectable concentration can be calculated by synthesizing the expected emission spectra and Los Alamos National Laboratory's Monte Carlo N-Particle transport code to simulate detector response. Traditionally, one of the steps in calculating a system's minimum detectable concentration is to place an appropriate button source under the detector, record the response, and then move the source by a specified increment. This process is repeated until the detector's spatial efficiency has been mapped. Due to the impracticality of performing this with Ra-226 button sources of varying decay times, Monte Carlo N-Particle transport code was utilized to determine the detector's spatial efficiency. A dime sized source with the established emission spectra was placed into the center of a rectangle of soil. This rectangle, including the source, was used as a lattice element to fill the region of space below the detector. The simulation was designed to track the energy distribution of pulses created in the sodium iodide crystal using the F8 tally, and was setup to isolate each source; thereby correlating detector response to source position. The simulation output required post-processing to determine conversion factors from counts per second to disintegrations per second. Post-processing accounted for subtraction of the Compton continuum, and average the data over the scanning pattern to obtain the expected spatial sensitivity during a characterization study. This was performed for the following photo-peaks: 609 keV (Bi-214), and 1764 keV (Bi-214). For calculation of the scan minimum detectable concentration, the surveyor efficiency coefficient from NUREG 1507 was supplanted in favor of a scan speed deviation factor. This was used because the detector utilizes computerized data collection (spatial and spectral). This report finds that, for two shielded 10.16 cm x 10.16 cm x 40.64 cm sodium-iodide crystals with integrated multi-channel analyzers, the minimum detectable concentration in surface soils is less than 1 pCi per gram Ra-226 for a 1 second survey measurement. These results assume a volumetric source with a maximum depth of 15.24 cm and a minimum decay time of 21 days. Verification of the system's capabilities was performed by sending soil samples from scanned areas, and locations where in-situ measurements were performed, to an independent laboratory for analysis. The laboratory results demonstrated that scanned area was principally comprised of soil containing less than 1 pCi per gram Ra-226. This borders the system MDC and it underestimated the concentration of radium in the soil. The probable causes of this is escape of radon gas from the surface soil. Radon is the daughter of radium, and has a high mobility in soil. If the gas escapes, then the progeny used as the detection proxy will be present in lower than expected concentrations. Radionuclide identification using high volume sodium-iodide crystals in low level characterization scans is demonstrated to be possible. Further system refinement will focus on developing a methodology to estimate a radon escape factor for site specific use. Accounting for radon escape in the top 15.24 cm of soil will allow the system to better estimate Ra-226 concentrations in soil. This is a significant advancement over the gross counting statistics used in most studies to satisfy MARSSIM survey requirements, because it will increase stakeholder confidence. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis techniques for background rejection at the Majorana Demonstrator

The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, 40-kg modular HPGe detector array to search for neutrinoless double beta decay in 76 Ge. In view of the next generation of tonne-scale Ge-based 0νββ-decay searches that will probe the neutrino mass scale in the inverted-hierarchy region, a major goal of the MAJORANA DEMONSTRATOR is to demonstrate a path forward to achieving a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value at 2039 keV. The background rejection techniques to be applied to the data include cuts based on data reduction, pulse shape analysis, event coincidences, and time correlations. The Point Contact design of the DEMONSTRATOR's germanium detectors allows for significant reduction of gamma background.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Numerical studies on saturated kink and sawtooth induced fast ion transport in JET ITER-like plasmas

Here, this presentation examines the energetic particle transport induced by saturated kink modes and sawtooth crashes in JET deuterium plasmas. It is known that kink mode-resonant transport and phase-space redistribution from sawtooth crashes can drive strong fast ion transport with dependencies on particle pitch and energy. Measurements with JET's Faraday cup fast ion loss detector array have shown that the internal kink growth phase preceding sawtooth crashes produces substantial fast ion losses. This report will numerically investigate the dominant energetic particle transport mechanism with a detailed examination of the fast ion phase-space dependencies, resonances, orbit topology changes, induced losses, and redistribution associated with the long-lived, resonant, kink mode and non-resonant sawtooth crash. The ORBIT-kick model forms the basis of the transport studies with realistic fast ion distributions produced from TRANSP. A recently created reduced model for sawtooth induced transport is used while the saturated kink modes are modeled with ideal MHD codes. The simulations were further validated against experiment with a newly developed synthetic Faraday cup fast ion loss detector in addition to scintillator probe and neutron measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active interrogation of Special Nuclear Material containers using AmBe quasi-forward biased directional source and PGNAA

Special Nuclear Material (SNM) including 95% 235 U and 239 Pu is capable of being identified by utilizing a quasi-forward directional AmBe source from Patent No: US20190013109A1 using Prompt Gamma Neutron Activation Analysis (PGNAA) simulated with Monte-Carlo N-Particle transport 6.2 (MCNP). HPGe and LaBr 3 detector arrays were used to identify and quantify the peak-to-background and peak-to-total ratios of the associated photon spectra from the SNM encased in a polyethylene shield. The conducted simulations varied the volume of the SNM and neutron source strength in the MCNP data card to conduct an uncertainty analysis. Photopeaks identified include K-shell X-rays from 235 U and 239 Pu, 61 keV from fission, 2.223 MeV prompt gamma from hydrogen, 511 keV annihilation, and a single and double escape peak from the prompt gamma interaction from hydrogen. Relationships between peak-to-total and peak-to-background as a function of SNM and particle history were investigated to aid in the analysis. The capabilities of both detector systems to acquire well resolved photopeak with a 5% relative error or less, with a 1 Ci source activity, and a peak-to-background ratio of 1.15. Finally, this was determined to take 326 s for LaBr 3 and 163 s for HPGe which is comparable to current methods for material detection which take between 100 and 900 s to acquire.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quick measurement of crystal truncation rod profiles in simultaneous multi-wavelength dispersive mode

To conduct time-resolved measurements in the wide momentum transfer (q = 4{pi} sin{theta}/{lambda}, {theta}: the glancing angle of the x-ray beam, {lambda}: x-ray wavelength) range of interest, we developed a method that can simultaneously measure the whole profile of x-ray diffraction and crystal truncation rod scattering of interest with no need of rotation of the specimen, detector, and monochromator crystal during the measurement. With a curved crystal polychromator (Si 111 diffraction), a horizontally convergent x-ray beam having a one-to-one correlation between wavelength (energy: 16.24-23.0 keV) and direction is produced. The convergent x-ray beam components of different wavelengths are incident on the specimen in a geometry where {theta} is the same for all the x-ray components and are diffracted within corresponding vertical scattering planes by a specimen ([GaAs(12ML)/AlAs(8 ML)]{sub 50} on GaAs(001) substrate) placed at the focal point. Although {theta} is the same for all the directions, q continuously varies because {lambda} changes as a function of direction. The normalized horizontal intensity distribution across the beam, as measured using a two-dimensional pixel array detector downstream of the specimen, represents the reflectivity curve profile both near to and far from the Bragg point. As for the crystal truncation rod scattering around the 002 reflection, the diffraction profile from the Bragg peak down to reflectivity of 1.0 x 10{sup -9} was measured with a sufficient data collection time (1000-2000 s). With data collection times of 100, 10, 1.0, and 0.1 s, profiles down to a reflectivity of {approx}6 x 10{sup -9}, {approx}2 x 10{sup -8}, {approx}8 x 10{sup -8}, and {approx}8 x 10{sup -7} were measured, respectively. To demonstrate the time-resolving capability of the system, reflectivity curves were measured with time resolutions of 1.0 s while rotating the specimen. We have also measured the diffraction profile around the 113 reflection in the non-specular reflection geometry.

36 MATERIALS SCIENCE↗