Search NASA⌕ Search

SEARCH · Search NASA

Results for “atomic clock,”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Linear ion trap based atomic frequency standard

In order to develop a trapped ion-based fieldable frequency standard with stability 1 x 10 to the -13th/sq rt tau for averaging times tau greater than 10,000 s, a hybrid RF/DC linear ion trap was developed which permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. The authors have confined Hg-199(+) ions in this trap and have measured very high Q transitions with good SNRs. In preliminary measurements they obtained stabilities of 1.6 x 10 to the -13th/sq rt tau (tau between 50 and 800 s) with a 160-mHz wide atomic resonance linewidth and a signal-to-noise ratio of 40 for each measurement cycle. Atomic resonance lines as narrow as 30 mHz on the 40.5-GHz clock transition have been measured with no appreciable reduction in the ion signal. A stability of 7 x 10 to the -14th/sq rt tau is made possible by the signal-to-noise and line Q of this measured transition. Analysis of fundamental sources of frequency instability indicates that a long-term stability of 2 x 10 to the -16th is feasible for this device with existing technology for tau = 10 to the 6th s or more.

Prestage, John D.↗

RACE and Calculations of Three-dimensional Distributed Cavity Phase Shifts

The design for RACE, a Rb-clock flight experiment for the ISS, is described. The cold collision shift and multiple launching (juggling) have important implications for the design and the resulting clock accuracy and stability. We present and discuss the double clock design for RACE. This design reduces the noise contributions of the local oscillator and simplifies and enhances an accuracy evaluation of the clock. As we try to push beyond the current accuracies of clocks, new systematic errors become important. The best fountain clocks are using cylindrical TE(sub 011) microwave cavities. We recently pointed out that many atoms pass through a node of the standing wave microwave field in these cavities. Previous studies have shown potentially large frequency shifts for atoms passing through nodes in a TE(sub 013) cavity. The shift occurs because there is a small traveling wave component due to the absorption of the copper cavity walls. The small traveling wave component leads to position dependent phase shifts. To study these effects, we perform Finite Element calculations. Three-dimensional Finite Element calculations require significant computer resources. Here we show that the cylindrical boundary condition can be Fourier decomposed to a short series of two-dimensional problems. This dramatically reduces the time and memory required and we obtain (3D) phase distributions for a variety of cavities. With these results, we will be able to analyze this frequency shift in fountain and future space clocks.

Li, Ruoxin↗

Nonlinear optical higher-order effects in an optical lattice clock

The development of optical frequency standards with a relative uncertainty of reproducing the time and frequency units at a level as low as 10{sup −17}–10{sup −18} calls for an unprecedented accuracy in estimating the role of higher orders of optical nonlinearity, caused by the influence of the optical lattice on the frequency shift of the ‘clock transition’. This paper presents a systematic calculation of the contributions of multipole nonlinear anharmonic effects to the error of clocks based on optical lattices for alkaline-earth-like Sr, Yb, and Hg atoms. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic trapping of Yb in the metastable {sup 3}P{sub 2} state

We report magnetic trapping of Yb in the excited {sup 3}P{sub 2} state. This state, with a lifetime of 15 s, could play an important role in studies ranging from optical clocks and quantum computation to the search for a permanent electric dipole moment. Yb atoms are first cooled and trapped in the ground state in a 399-nm magneto-optic trap. The cold atoms are then pumped into the excited state by driving the {sup 1}S{sub 0{yields}}{sup 3}P{sub 1{yields}}{sup 3}S{sub 1} transition. Atoms in the {sup 3}P{sub 2} state are magnetically trapped in a spherical quadrupole field with an axial gradient of 110 G/cm. We trap up to 10{sup 6} atoms with a lifetime of 1.5 s.

74 ATOMIC AND MOLECULAR PHYSICS↗

Universal scaling in the aging of the strong glass former SiO{sub 2}

We show that the aging dynamics of a strong glass former displays a strikingly simple scaling behavior, connecting the average dynamics with its fluctuations, namely, the dynamical heterogeneities. We perform molecular dynamics simulations of SiO{sub 2} with van Beest-Kramer-van Santen interactions, quenching the system from high to low temperature, and study the evolution of the system as a function of the waiting time t{sub w} measured from the instant of the quench. We find that both the aging behavior of the dynamic susceptibility χ{sub 4} and the aging behavior of the probability distribution P(f{sub s,r}) of the local incoherent intermediate scattering function f{sub s,r} can be described by simple scaling forms in terms of the global incoherent intermediate scattering function C. The scaling forms are the same that have been found to describe the aging of several fragile glass formers and that, in the case of P(f{sub s,r}), have been also predicted theoretically. A thorough study of the length scales involved highlights the importance of intermediate length scales. We also analyze directly the scaling dependence on particle type and on wavevector q and find that both the average and the fluctuations of the slow aging dynamics are controlled by a unique aging clock, which is not only independent of the wavevector q, but is also the same for O and Si atoms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photonics Breakthroughs 2024: Narrow-Linewidth Lasers in the Visible and Near-Infrared

Narrow-linewidth lasers enable a variety of high-precision applications, such as sensing, optical clocks, and microwave frequency generation. Advances in photonic integration in the last decade led to the development of ultra-low-noise integrated semiconductor lasers, mostly in the telecom wavelength range. In recent years, the demand for high-performance lasers at shorter wavelengths skyrocketed, driven by applications in sensing and atom trapping. Low-noise lasers are of particular importance in this spectral range, as they are essential for optical clocks. Here, we will review recent progress in narrow-linewidth lasers at shorter wavelengths, present results on a hybrid-integrated low-noise laser at 780 nm and discuss the perspectives and challenges of high-performance semiconductor lasers in the visible and near-infrared.

Prokoshin, Artem [King Abdullah University of Scie↗

Cold-collision-shift cancellation and inelastic scattering in a Yb optical lattice clock

Recently, p-wave cold collisions were shown to dominate the density-dependent shift of the clock transition frequency in a {sup 171}Yb optical lattice clock. Here we demonstrate that by operating such a system at the proper excitation fraction, the cold-collision shift is canceled below the 5x10{sup -18} fractional frequency level. We report inelastic two-body loss rates for {sup 3} P{sub 0} -{sup 3} P{sub 0} and {sup 1} S{sub 0} -{sup 3} P{sub 0} scattering. We also measure interaction shifts in an unpolarized atomic sample. Collision measurements for this spin-1/2 {sup 171}Yb system are relevant for high-performance optical clocks as well as strongly interacting systems for quantum information and quantum simulation applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

An algorithm for the Italian atomic time scale

During the past twenty years, the time scale at the IEN has been realized by a commercial cesium clock, selected from an ensemble of five, whose rate has been continuously steered towards UTC to maintain a long term agreement within 3 x 10(exp -13). A time scale algorithm, suitable for a small clock ensemble and capable of improving the medium and long term stability of the IEN time scale, has been recently designed taking care of reducing the effects of the seasonal variations and the sudden frequency anomalies of the single cesium clocks. The new time scale, TA(IEN), is obtained as a weighted average of the clock ensemble computed once a day from the time comparisons between the local reference UTC(IEN) and the single clocks. It is foreseen to include in the computation also ten cesium clocks maintained in other Italian laboratories to further improve its reliability and its long term stability. To implement this algorithm, a personal computer program in Quick Basic has been prepared and it has been tested at the IEN time and frequency laboratory. Results obtained using this algorithm on the real clocks data relative to a period of about two years are presented.

Cordara, F.↗

Time maintenance system for the BMDO MSX spacecraft

The Johns Hopkins University Applied Physics Laboratory (APL) is responsible for designing and implementing a clock maintenance system for the Ballistic Missile Defense Organizations (BMDO) Midcourse Space Experiment (MSX) spacecraft. The MSX spacecraft has an on-board clock that will be used to control execution of time-dependent commands and to time tag all science and housekeeping data received from the spacecraft. MSX mission objectives have dictated that this spacecraft time, UTC(MSX), maintain a required accuracy with respect to UTC(USNO) of +/- 10 ms with a +/- 1 ms desired accuracy. APL's atomic time standards and the downlinked spacecraft time were used to develop a time maintenance system that will estimate the current MSX clock time offset during an APL pass and make estimates of the clock's drift and aging using the offset estimates from many passes. Using this information, the clock's accuracy will be maintained by uplinking periodic clock correction commands. The resulting time maintenance system is a combination of offset measurement, command/telemetry, and mission planning hardware and computing assets. All assets provide necessary inputs for deciding when corrections to the MSX spacecraft clock must be made to maintain its required accuracy without inhibiting other mission objectives. The MSX time maintenance system is described as a whole and the clock offset measurement subsystem, a unique combination of precision time maintenance and measurement hardware controlled by a Macintosh computer, is detailed. Simulations show that the system estimates the MSX clock offset to less than+/- 33 microseconds.

Hermes, Martin J.↗

'Doubly Magic' Conditions in Magic-Wavelength Trapping of Ultracold Alkali-Metal Atoms

In experiments with trapped atoms, atomic energy levels are shifted by the trapping optical and magnetic fields. Regardless of this strong perturbation, precision spectroscopy may be still carried out using specially crafted, 'magic' trapping fields. Finding these conditions for particularly valuable microwave transitions in alkali-metal atoms has so far remained an open challenge. Here I demonstrate that the microwave transitions in alkali-metal atoms may be indeed made impervious to both trapping laser intensity and fluctuations of magnetic fields. I consider driving multiphoton transitions between the clock levels and show that these 'doubly magic' conditions are realized at special values of trapping laser wavelengths and fixed values of relatively weak magnetic fields. This finding has implications for precision measurements and quantum information processing with qubits stored in hyperfine manifolds.

74 ATOMIC AND MOLECULAR PHYSICS↗

Test of Lorentz Invariance with Spin Precession of Ultracold Neutrons

A clock comparison experiment, analyzing the ratio of spin precession frequencies of stored ultracold neutrons and {sup 199}Hg atoms, is reported. No daily variation of this ratio could be found, from which is set an upper limit on the Lorentz invariance violating cosmic anisotropy field b{sub perpendicular}<2x10{sup -20} eV (95% C.L.). This is the first limit for the free neutron. This result is also interpreted as a direct limit on the gravitational dipole moment of the neutron |g{sub n}|<0.3 eV/c{sup 2} m from a spin-dependent interaction with the Sun. Analyzing the gravitational interaction with the Earth, based on previous data, yields a more stringent limit |g{sub n}|<3x10{sup -4} eV/c{sup 2} m.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the second-order Zeeman effect on the sodium clock transition in the weak-magnetic-field region using the scalar Aharonov-Bohm phase

The second-order Zeeman effect of the sodium clock transition in a weak magnetic field of less than 50 {mu}T was measured as the scalar Aharonov-Bohm phase by two-photon stimulated Raman atom interferometry. The ac Stark effect of the Raman pulse was canceled out by adopting an appropriate intensity ratio of two photons in the Raman pulse. The Ramsey fringes for the pulse separation of 7 ms were obtained with a phase uncertainty of {pi}/200 rad. The nondispersive feature of the scalar Aharonov-Bohm phase was clearly demonstrated through 18 fringes with constant amplitude. The Breit-Rabi formula of the sodium clock transition was verified to be {Delta}{nu}=(0.222{+-}0.003)x10{sup 12}xB{sup 1.998{+-}0.004} in a magnetic field of less than 50 {mu}T.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Long-term performance of the Johns Hopkins-built hydrogen maser

The long-term clock capabilities of the Johns Hopkins-built hydrogen maser are evaluated by comparing the measured results with international atomic references. The performance of the NR-6 hydrogen maser from April 29, 1984 to April 29, 1986 is examined. It is noted that the timekeeping in a hydrogen maser (NR-6) is comparable to the best standards of Germany and Canada.

Rueger, Lauren J.↗

Injection locking of a high power ultraviolet laser diode for laser cooling of ytterbium atoms

We developed a high-power laser system at a wavelength of 399 nm for laser cooling of ytterbium atoms with ultraviolet laser diodes. The system is composed of an external cavity laser diode providing frequency stabilized output at a power of 40 mW and another laser diode for amplifying the laser power up to 220 mW by injection locking. The systematic method for optimization of our injection locking can also be applied to high power light sources at any other wavelengths. Our system does not depend on complex nonlinear frequency-doubling and can be made compact, which will be useful for providing light sources for laser cooling experiments including transportable optical lattice clocks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of Cavity Squeezing of a Collective Atomic Spin

We squeeze unconditionally the collective spin of a dilute ensemble of laser-cooled {sup 87}Rb atoms using their interaction with a driven optical resonator. The shape and size of the resulting spin uncertainty region are well described by a simple analytical model [M. H. Schleier-Smith, I. D. Leroux, and V. Vuletic, arXiv:0911.3936 [Phys. Rev. A (to be published)]] through 2 orders of magnitude in the effective interaction strength, without free parameters. We deterministically generate states with up to 5.6(6) dB of metrologically relevant spin squeezing on the canonical {sup 87}Rb hyperfine clock transition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

It's About Time!

Everything we do in VLBI is connected to time. In this contribution, we review 28 orders of magnitude of the spectrum of time ranging from a few hundred femtoseconds (i.e. one degree of phase at X-band - Pi x 10(exp -13) seconds) upwards to tens of millions of years (i.e. ten million years Pi x 10(exp 14) seconds). In this discussion, we will pay special attention to the relation between the underlying oscillator (the frequency standard that defines a clock's rate) and the time kept by the clock (which counts the oscillations of the frequency standard). We will consider two different types of time - time kept by counting an atomic frequency standard (Hydrogen Maser or Cesium), and time reckoned by the rotation of the Earth underneath the stars and sun.

Clark, Tom↗