Search NASA⌕ Search

SEARCH · Search NASA

Results for “biomedical data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

3D printing of High Precision Radiation Filters for next generation Cosmic Background (CMB) studies (Final Report)

The terahertz (THz) spectral range is the part of the electromagnetic spectrum between 0.1–10 THz or 0.03–3 mm wavelength. For a long period, the terahertz band was relatively unexplored due to the unavailability of cost-effective and powerful sources. Due to the evolution of these devices in the mid-1980s, however, terahertz radiation has attracted much more attention. Since this part of the spectrum is between the infrared (IR) and microwave frequency ranges, the development of waveguides, filters, polarizers, lenses, and other optical components. Since terahertz waves to penetrate most dielectric materials offers the possibility of many applications. Since terahertz radiation can pass through organic tissue without causing damage, and it can be safely applied for biomedical applications. Radio astronomy and wireless communication are also fields with great interest in this spectral range. For example, terahertz waves could be used to detect cold bodies and debris in space or to increase data transmission using the larger bandwidth of the terahertz band.

79 ASTRONOMY AND ASTROPHYSICS↗

Image-Processing Program

IMAGEP manipulates digital image data to effect various processing, analysis, and enhancement functions. It is keyboard-driven program organized into nine subroutines. Within subroutines are sub-subroutines also selected via keyboard. Algorithm has possible scientific, industrial, and biomedical applications in study of flows in materials, analysis of steels and ores, and pathology, respectively.

Roth, D. J.↗

Cath Lab Robotics: Paradigm Change in Interventional Cardiology?

Purpose of Review: To review the contemporary evidence for robotic-assisted percutaneous coronary and vascular interventions, discussing its current capabilities, limitations, and potential future applications. Recent Findings: Robotic-assisted cardiovascular interventions significantly reduce radiation exposure and orthopedic strains for interventionalists, while maintaining high rates of device and clinical success. The PRECISE and CORA-PCI studies demonstrated the safety and efficacy of robotic-assisted percutaneous coronary intervention (PCI) in increasingly complex coronary lesions. The RAPID study demonstrated similar findings in peripheral vascular interventions (PVI). Subsequent studies have demonstrated the safety and efficacy of second-generation devices, with automations mimicking manual PCI techniques. While innovations such as telestenting continue to bring excitement to the field, major limitations remain—particularly the lack of randomized trials comparing robotic-assisted PCI with manual PCI. Summary: Robotic technology has successfully been applied to multiple cardiovascular procedures. There are limited data to evaluate outcomes with robotic-assisted PCI and other robotic-assisted cardiovascular procedures, but existing data show some promise of improving the precision of PCI while decreasing occupational hazards associated with radiation exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

EWALD: A macromolecular diffractometer for the second target station

Revealing the positions of all the atoms in large macromolecules is powerful but only possible with neutron macromolecular crystallography (NMC). Neutrons provide a sensitive and gentle probe for the direct detection of protonation states at near-physiological temperatures and clean of artifacts caused by x rays or electrons. Currently, NMC use is restricted by the requirement for large crystal volumes even at state-of-the-art instruments such as the macromolecular neutron diffractometer at the Spallation Neutron Source. EWALD’s design will break the crystal volume barrier and, thus, open the door for new types of experiments, the study of grand challenge systems, and the more routine use of NMC in biology. EWALD is a single crystal diffractometer capable of collecting data from macromolecular crystals on orders of magnitude smaller than what is currently feasible. The construction of EWALD at the Second Target Station will cause a revolution in NMC by enabling key discoveries in the biological, biomedical, and bioenergy sciences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-F-CAMPUS-I-04: Magnetic Resonance Imaging of An in Vitro 3D Tumor Model

Purpose: To investigate the use of an in vitro 3D tumor model (tumoroid) as a bio-phantom for repetitive and sequential magnetic resonance imaging (MRI) studies. Methods: The tissue engineered tumoroid comprised an artificial cancer mass (ACM) containing 30 million HT29 cancer cells seeded in a collagen type I matrix, whose density was increased by plastic compression (dry/wet weight=40%). The ACM was embedded in an uncompressed collagen gel that mimicked the tumor stroma, and the tumoroid was incubated for 24h before imaging. Images were acquired using the 1T ICON™ (Bruker Corporation, Billerica, MA) MRI scanner. T1 maps were calculated using an IR-RARE sequence (TE=12ms, TR=10000ms, 7 inversion times), while for T2 maps a MSME technique (TR=6000ms, 16 echoes) was used. T1 and T2 fittings were performed using a pixel-wise approach to produce relaxometric parametric maps. Results: The images acquired and corresponding T1 and T2 maps indicate contrast between the ACM and the stroma. T1 was 2500 and 2800ms, while T2 was 520 and 760ms, for the ACM and stroma respectively. The ACM construct was not homogenous and internal features were visible, which can be explained by local gradients of cell and/or collagen density. The viability of the cells was confirmed via confocal microscopy for several days after the imaging session, demonstrating the suitability of the tumoroid for sequential imaging studies. Conclusions: We have engineered a tumor model compatible with repetitive and sequential MRI. We found T1 and T2 contrast between the ACM and stroma using a pre-clinical MRI scanner. The model, which enables controllable cell and matrix densities, has potential for a wide range of applications in radiotherapy, such as to study tumor progression and to validate imaging biomarkers. Further work is necessary to understand the mechanisms behind the contrast achieved, and to correlate findings with biology and histology data.

60 APPLIED LIFE SCIENCES↗

Noninvasive assessment of mitral inertness: clinical results with numerical model validation

Inertial forces (Mdv/dt) are a significant component of transmitral flow, but cannot be measured with Doppler echo. We validated a method of estimating Mdv/dt. Ten patients had a dual sensor transmitral (TM) catheter placed during cardiac surgery. Doppler and 2D echo was performed while acquiring LA and LV pressures. Mdv/dt was determined from the Bernoulli equation using Doppler velocities and TM gradients. Results were compared with numerical modeling. TM gradients (range: 1.04-14.24 mmHg) consisted of 74.0 +/- 11.0% inertial forcers (range: 0.6-12.9 mmHg). Multivariate analysis predicted Mdv/dt = -4.171(S/D (RATIO)) + 0.063(LAvolume-max) + 5. Using this equation, a strong relationship was obtained for the clinical dataset (y=0.98x - 0.045, r=0.90) and the results of numerical modeling (y=0.96x - 0.16, r=0.84). TM gradients are mainly inertial and, as validated by modeling, can be estimated with echocardiography.

NASA Discipline Cardiopulmonary↗

Truly incomplete and complex exchanges in prematurely condensed chromosomes of human fibroblasts exposed in vitro to energetic heavy ions

Confluent human fibroblast cells (AG1522) were irradiated with gamma rays, 490 MeV/nucleon silicon ions, or iron ions at either 200 or 500 MeV/nucleon. The cells were allowed to repair at 37 degrees C for 24 h after exposure, and a chemically induced premature chromosome condensation (PCC) technique was used to condense chromosomes in the G2 phase of the cell cycle. Incomplete and complex exchanges were analyzed in the irradiated samples. To verify that chromosomal breaks were truly unrejoined, chromosome aberrations were analyzed using a combination of whole-chromosome specific probes and probes specific for the telomere region of the chromosome. Results showed that the frequency of unrejoined chromosome breaks was higher after irradiation with the heavy ions of high LET, and consequently the ratio of incomplete to complete exchanges increased steadily with LET up to 440 keV/microm, the highest LET included in the present study. For samples exposed to 200 MeV/nucleon iron ions, chromosome aberrations were analyzed using the multicolor FISH (mFISH) technique, which allows identification of both complex and truly incomplete exchanges. Results of the mFISH study showed that 0.7 and 3 Gy iron ions produced similar ratios of complex to simple exchanges and incomplete to complete exchanges; these ratios were higher than those obtained after exposure to 6 Gy gamma rays. After 0.7 Gy of iron ions, most complex aberrations were found to involve three or four chromosomes, which is a likely indication of the maximum number of chromosome domains traversed by a single iron-ion track.

NASA Discipline Radiation Health↗

Technical Note: Synchrotron-based high-energy x-ray phase sensitive microtomography for biomedical research

Purpose: Propagation-based phase-contrast CT (PPCT) utilizes highly sensitive phase-contrast technology applied to x-ray microtomography. Performing phase retrieval on the acquired angular projections can enhance image contrast and enable quantitative imaging. In this work, the authors demonstrate the validity and advantages of a novel technique for high-resolution PPCT by using the generalized phase-attenuation duality (PAD) method of phase retrieval. Methods: A high-resolution angular projection data set of a fish head specimen was acquired with a monochromatic 60-keV x-ray beam. In one approach, the projection data were directly used for tomographic reconstruction. In two other approaches, the projection data were preprocessed by phase retrieval based on either the linearized PAD method or the generalized PAD method. The reconstructed images from all three approaches were then compared in terms of tissue contrast-to-noise ratio and spatial resolution. Results: The authors’ experimental results demonstrated the validity of the PPCT technique based on the generalized PAD-based method. In addition, the results show that the authors’ technique is superior to the direct PPCT technique as well as the linearized PAD-based PPCT technique in terms of their relative capabilities for tissue discrimination and characterization. Conclusions: This novel PPCT technique demonstrates great potential for biomedical imaging, especially for applications that require high spatial resolution and limited radiation exposure.

60 APPLIED LIFE SCIENCES↗

Solving the Big Data (BD) Problem in Advanced Manufacturing (Subcategory for work done at Georgia Tech. Study Process and Design Factors for Additive Manufacturing Improvement)

3D printing originally known as additive manufacturing is a process of making 3 dimensional solid objects from a CAD file. This ground breaking technology is widely used for industrial and biomedical purposes such as building objects, tools, body parts and cosmetics. An important benefit of 3D printing is the cost reduction and manufacturing flexibility; complex parts are built at the fraction of the price. However, layer by layer printing of complex shapes adds error due to the surface roughness. Any such error results in poor quality products with inaccurate dimensions. The main purpose of this research is to measure the amount of printing errors for parts with different geometric shapes and to analyze them for finding optimal printing settings to minimize the error. We use a Design of Experiments framework, and focus on studying parts with cone and ellipsoid shapes. We found that the orientation and the shape of geometric shapes have significant effect on the printing error. From our analysis, we also determined the optimal orientation that gives the least printing error.

36 MATERIALS SCIENCE↗

INCREASING THE TRANSPARENCY AND REPRODUCIBILITY OF SPACE RADIATION SCIENCE: THE RADIATION BIOLOGY ONTOLOGY

Among the primary objectives of the Open/Open-Source Science paradigm are making scientific investigation data transparent and results reproducible [1], objectives shared by the FAIR principles [2]. To accomplish this, the conceptual framework that includes all the investigation objects needs to be accurately captured and communicated to all data consumers. A large part of this requires using metadata standards to annotate data collected. These standards should be readily accessible, informed by scientific community consensus and sufficiently specific to encompass all of the important aspects of the investigation. Starting in 2020 we have been co-leading an open consortium to develop a new metadata standard, the Radiation Biology Ontology (RBO), through the Open Biological and Biomedical Ontologies (OBO) Foundry [3]. We began by transforming many of the terms from the National Council on Radiation Protection and Measurement into concepts that can be formally related to existing OBO Foundry classes or attributes. We then identified and imported into the RBO existing OBO Foundry classes that have obvious relevance for radiation biomedicine (for example, concepts from the Environment Ontology that describe radiative processes, and concepts from the Gene Ontology dealing with molecular and cellular responses to radiation). Finally, we scrutinized datasets from investigations of radiation effects held in NASA GeneLab and LSDA repositories and added additional classes, instances, and attributes into the RBO that should be used to annotate these data. We developed the RBO using the open-source tools of GitHub and publish the RBO periodically through the NIH/NCBI BioPortal website, so systems worldwide can leverage the knowledge it contains [4]. This initial phase of concept modeling has yielded an RBO that at present has more than 300 declared concepts, with more than 3500 additional concepts imported from other OBO Foundry ontologies. While this first phase has focused on concepts for annotating samples, environments, exposures, and measurements, the next phase will center on supporting annotation of results and findings, such as concept models of molecular, cellular and tissue effects. The value of the RBO will be determined in part by our ability to engage the community in its development, and we have established a Radiobiology Informatics Consortium with unrestricted membership as the owner of the RBO in order to encourage investigators, system owners and other to join in this effort. Anyone can report issues or request new concept modeling or other features directly on GitHub. By using the BioPortal application programming interface, systems can pose dynamic queries to the latest version of the RBO for information on individual classes or entire hierarchies; this design eliminates the need for systems to be updated in order to use newer versions of the RBO. We hope to contribute to the advancement of open radiobiological science through the continued, open development of the RBO, that will provide more precise, machine-interpretable descriptions of investigations, as well as support data meta-analysis through machine learning or other artificial intelligence methods.

knowledge↗

Weighted simultaneous algebraic reconstruction technique for tomosynthesis imaging of objects with high-attenuation features

Purpose: This paper introduces a nonlinear weighting scheme into the backprojection operation within the simultaneous algebraic reconstruction technique (SART). It is designed for tomosynthesis imaging of objects with high-attenuation features in order to reduce limited angle artifacts. Methods: The algorithm estimates which projections potentially produce artifacts in a voxel. The contribution of those projections into the updating term is reduced. In order to identify those projections automatically, a four-dimensional backprojected space representation is used. Weighting coefficients are calculated based on a dissimilarity measure, evaluated in this space. For each combination of an angular view direction and a voxel position an individual weighting coefficient for the updating term is calculated. Results: The feasibility of the proposed approach is shown based on reconstructions of the following real three-dimensional tomosynthesis datasets: a mammography quality phantom, an apple with metal needles, a dried finger bone in water, and a human hand. Datasets have been acquired with a Siemens Mammomat Inspiration tomosynthesis device and reconstructed using SART with and without suggested weighting. Out-of-focus artifacts are described using line profiles and measured using standard deviation (STD) in the plane and below the plane which contains artifact-causing features. Artifacts distribution in axial direction is measured using an artifact spread function (ASF). The volumes reconstructed with the weighting scheme demonstrate the reduction of out-of-focus artifacts, lower STD (meaning reduction of artifacts), and narrower ASF compared to nonweighted SART reconstruction. It is achieved successfully for different kinds of structures: point-like structures such as phantom features, long structures such as metal needles, and fine structures such as trabecular bone structures. Conclusions: Results indicate the feasibility of the proposed algorithm to reduce typical tomosynthesis artifacts produced by high-attenuation features. The proposed algorithm assigns weighting coefficients automatically and no segmentation or tissue-classification steps are required. The algorithm can be included into various iterative reconstruction algorithms with an additive updating strategy. It can also be extended to computed tomography case with the complete set of angular data.

60 APPLIED LIFE SCIENCES↗

Supporting Information for manuscript: “A latitudinal gradient in S/G lignin monomer ratio driven by laccase in natural poplar variants”

Lignin composition plays a crucial role in plant structural integrity and environmental adaptation. However, the genetic and molecular mechanisms underlying natural variation in lignin composition remain poorly understood. This study investigates the syringyl-to-guaiacyl (S/G) lignin monomer ratio across a natural population of Populus trichocarpa spanning a latitudinal gradient along the Northwest coast of North America. By integrating biochemical, genomic, and geographic analysis, we identify key gene variants associated with S/G ratio differences. These datasets provide valuable insights into the evolutionary and functional genomics of lignin composition and serve as a resource for developing poplar variants optimized for forestry and bioenergy applications.

Poplar, lignin composition, laccases, latitude, ad↗

Flight operations and performance of Skylab life support and environmental control systems

The design and performance of the Skylab thermal and environmental control systems is considered. The Orbital Workshop had a combined active and passive thermal control system. The refrigeration system was designed to store food and biomedical samples and to cool drinking water. The atmosphere control system included active humidity control, molecular sieves and charcoal canisters to control carbon dioxide, odor, and contaminants, and the gas supply system. Mission support preparation, including instrumentation, ground data system, system troubleshooting, and training, is surveyed. Major in-flight anomalies occurred with the thermal control system when the meteoroid shield was lost during SL-1 ascent and when the Airlock Module coolant loop malfunctioned during SL-2 manned operations. The atmosphere control system performed without major anomaly throughout the manned missions.

Hopson, G. D.↗

Veterinary medical considerations for the use of nonhuman primates in space research

The validity of biomedical research using animal subjects is highly dependent on the use of 'normal' and healthy animals. The current costs of research programs dictate that a minimum number of animals and test replicates be used to obtain the desired data. The use of healthy and standardized animals increases the probability of obtaining valid data while also permitting greater economy by reducing the between-individual variation, thus allowing the use of fewer animals. Areas of concern when planning animal payloads include constraints of the flight on candidate species selection, screening for physiological and psychological normalcy, procedures for routine care and quarantine of new animals and those returning from space, ground-based studies to determine experimental protocol, selection of instrumentation, stress during transportation for flight operations, housing and care facilities at launch and recovery sites, and the overall veterinary program.

Simmonds, R. C.↗

Pricing of NASA Space Shuttle transportation system cargo

A two-part pricing policy is investigated as the most feasible method of pricing the transportation services to be provided by NASA's SSTS. Engineering cost estimates and a deterministic operating cost model generate a data base and develop a procedure for pricing the services of the SSTS. It is expected that the SSTS will have a monopoly on space material processing in areas of crystal growth, glass processing, metallurgical space applications, and biomedical processes using electrophoresis which will require efficient pricing. Pricing problems, the SSTS operating costs based on orbit elevation, number of launch sites, and number of flights, capital costs of the SSTS, research and development costs, allocation of joint transportation costs of the SSTS to a particular space processing activity, and rates for the SSTS are discussed. It is concluded that joint costs for commercial cargoes carried in the SSTS can be most usefully handled by making cost allocations based on proportionate capacity utilization.

Hale, C. W.↗

Method and apparatus for measuring biofilm thickness and topology

An apparatus and method of measuring biofilm and biological activity on a surface is disclosed. The apparatus includes a biofilm, which includes one or more microorganisms, grown on a substrate. A viewing window is placed on a surface of the biofilm and a gas bubble is introduced between the viewing window and the surface of the biofilm. The space between the substrate and the viewing window may be enclosed in a casing that has an inlet and an outlet, forming a flow cell. A microscope system, such as a white light interferometer, captures data of the biofilm in situ and non-destructively. The 3D images of biofilm surface have high resolution while maintaining a large field of view. The apparatuses and methods will be useful for fundamental studies of biofilms, biomedical and environmental screening, and many other applications in biology and the life sciences.

Larimer, Curtis J.↗

Creating Benchmark Data for Artificial Intelligence and Machine Learning Space Biology Research

To identify an appropriate AI/ML approach for a specific problem, the best practice is to measure algorithm performance through the benchmarking process. A scientific benchmark consists of an AI-ready dataset and a reference implementation on a specific scientific question. The NASA Science Mission Directorate (SMD) has started the “Benchmark Initiative for AI/ML to create scientific benchmark datasets in three applications: 1) scientific benchmarking, which finds the best algorithm for a specific problem; 2) application benchmarking, which measures algorithm performance against a set of parameters; and 3) system benchmarking, which evaluates performance of hardware and software architecture. Currently, there are no standardized datasets available to benchmark AI/ML algorithms in the domain of space biology. In this work, we constructed two AI/ML-ready biological datasets from experiments in space-flown mice: cellular imaging and RNA-seq. First, radiation-exposed immune cells harbor DNA damage foci that can be fluorescently marked to visualize the amount of damage following exposure to ionizing radiation. However, such large datasets are difficult to analyze visually, due to imaging inconsistencies and human bias, and classical image processing approaches can fail on imaging artifacts. AI/ML are therefore exciting alternative, providing the speed of machines and the accuracy of humans. We have made this dataset available at https://registry.opendata.aws/bps_microscopy/. Second, high-throughput nucleic acid sequencing (DNA-seq, RNA-seq) has become widespread in biomedical research due to the growing availability and affordability of these assays. However, most sequencing datasets suffer from high dimensionality and low sample count. In this work, we used a generative adversarial network to synthesize a standardized, AI-ready, publicly available benchmark dataset for space biology RNA-seq data with sufficient space-flown and ground control mouse liver samples from NASA GeneLab. This dataset is available at https://registry.opendata.aws/bps_rnaseq/. These datasets are now fully open the Space Biology community to test their favorite AI/ML approaches.

James Casaletto↗

MO-F-16A-06: Implementation of a Radiation Exposure Monitoring System for Surveillance of Multi-Modality Radiation Dose Data

Purpose: We have implemented a commercially available Radiation Exposure Monitoring System (REMS) to enhance the processes of radiation dose data collection, analysis and alerting developed over the past decade at our sites of practice. REMS allows for consolidation of multiple radiation dose information sources and quicker alerting than previously developed processes. Methods: Thirty-nine x-ray producing imaging modalities were interfaced with the REMS: thirteen computed tomography scanners, sixteen angiography/interventional systems, nine digital radiography systems and one mammography system. A number of methodologies were used to provide dose data to the REMS: Modality Performed Procedure Step (MPPS) messages, DICOM Radiation Dose Structured Reports (RDSR), and DICOM header information. Once interfaced, the dosimetry information from each device underwent validation (first 15–20 exams) before release for viewing by end-users: physicians, medical physicists, technologists and administrators. Results: Before REMS, our diagnostic physics group pulled dosimetry data from seven disparate databases throughout the radiology, radiation oncology, cardiology, electrophysiology, anesthesiology/pain management and vascular surgery departments at two major medical centers and four associated outpatient clinics. With the REMS implementation, we now have one authoritative source of dose information for alerting, longitudinal analysis, dashboard/graphics generation and benchmarking. REMS provides immediate automatic dose alerts utilizing thresholds calculated through daily statistical analysis. This has streamlined our Closing the Loop process for estimated skin exposures in excess of our institutional specific substantial radiation dose level which relied on technologist notification of the diagnostic physics group and daily report from the radiology information system (RIS). REMS also automatically calculates the CT size-specific dose estimate (SSDE) as well as provides two-dimensional angulation dose maps for angiography/interventional procedures. Conclusion: REMS implementation has streamlined and consolidated the dosimetry data collection and analysis process at our institutions while eliminating manual entry error and providing immediate alerting and access to dosimetry data to both physicists and physicians. Brent Stewart has funded research through GE Healthcare.

60 APPLIED LIFE SCIENCES↗