Search NASA⌕ Search

SEARCH · Search NASA

Results for “bragg diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Lattice and magnetic structure in the van der Waals antiferromagnet VBr 3

Here, we report a comprehensive investigation of the lattice and magnetic structure in van der Waals antiferromagnet VBr 3 , characterized by a BiI 3 -type structure at room temperature. Neutron diffraction experiments were performed on both polycrystalline and single-crystalline VBr 3 samples, revealing clear magnetic Bragg peaks emerging below the Néel temperature of T N =26.5 K. These magnetic Bragg peaks can be indexed by k=(0, 0.5, 1) in hexagonal notation. Our refinement analysis suggests that the antiferromagnetic order in VBr 3 manifests as a zigzag structure. Moreover, we observed peak splitting for nuclear Bragg peaks in the HK plane below the structure transition temperature of T S =90.4 K, indicating the breaking of threefold symmetry within the ab plane.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In-situ temperature-controllable shear flow device for neutron scattering measurement—An example of aligned bicellar mixtures

We have designed and constructed a temperature-controllable shear flow cell for in-situ study on flow alignable systems. The device has been tested in the neutron diffraction and has the potential to be applied in the small angle neutron scattering configuration to characterize the nanostructures of the materials under flow. The required sample amount is as small as 1 ml. The shear rate on the sample is controlled by the flow rate produced by an external pump and can potentially vary from 0.11 to 3.8 × 10{sup 5} s{sup −1}. Both unidirectional and oscillational flows are achievable by the setting of the pump. The instrument is validated by using a lipid bicellar mixture, which yields non-alignable nanodisc-like bicelles at low T and shear-alignable membranes at high T. Using the shear cell, the bicellar membranes can be aligned at 31 °C under the flow with a shear rate of 11.11 s{sup −1}. Multiple high-order Bragg peaks are observed and the full width at half maximum of the “rocking curve” around the Bragg’s condition is found to be 3.5°–4.1°. It is noteworthy that a portion of the membranes remains aligned even after the flow stops. Detailed and comprehensive intensity correction for the rocking curve has been derived based on the finite rectangular sample geometry and the absorption of the neutrons as a function of sample angle [See supplementary material at http://dx.doi.org/10.1063/1.4908165 for the detailed derivation of the absorption correction]. The device offers a new capability to study the conformational or orientational anisotropy of the solvated macromolecules or aggregates induced by the hydrodynamic interaction in a flow field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent X-ray diffraction imaging and characterization of strain in silicon-on-insulator nanostructures

Coherent X-ray diffraction imaging (CDI) has emerged in the last decade as a promising high resolution lens-less imaging approach for the characterization of various samples. It has made significant technical progress through developments in source, algorithm and imaging methodologies thus enabling important scientific breakthroughs in a broad range of disciplines. In this report, we will introduce the principles of forward scattering CDI and Bragg geometry CDI (BCDI), with an emphasis on the latter. BCDI exploits the ultra-high sensitivity of the diffraction pattern to the distortions of crystalline lattice. Its ability of imaging strain on the nanometer scale in three dimensions is highly novel. We will present the latest progress on the application of BCDI in investigating the strain relaxation behavior in nanoscale patterned strained silicon-on-insulator (sSOI) materials, aiming to understand and engineer strain for the design and implementation of new generation semiconductor devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The interplay of microstructure and magnetism in La{sub 3}Ni{sub 2}SbO{sub 9}

La{sub 3}Ni{sub 2}SbO{sub 9} adopts a perovskite-related structure in which the six-coordinate cation sites are occupied alternately by Ni{sup 2+} and a disordered arrangement of Ni{sup 2+}/Sb{sup 5+}. A polycrystalline sample has been studied by neutron diffraction in applied magnetic fields of 0≤H/kOe≤50 at 5 K. In 0 kOe, weak magnetic Bragg scattering consistent with the adoption of a G-type ferrimagnetic structure is observed; the ordered component of the magnetic moment was found to be 0.89(7) µ{sub B} per Ni{sup 2+} cation. This increased to 1.60(3) µ{sub B} in a field of 50 kOe. Transmission electron microscopy revealed variations in the Ni:Sb ratio across crystallites of the sample. It is proposed that these composition variations disrupt the magnetic superexchange interactions within the compound, leading to domain formation and a reduced average moment. The application of a magnetic field aligns the magnetisation vectors across the crystal and the average moment measured by neutron diffraction increases accordingly. The role played by variations in the local chemical composition in determining the magnetic properties invites comparison with the behaviour of relaxor ferroelectrics. - Graphical abstract: Composition variations across a crystal of La3Ni2SbO9 result in anomalous magnetic behavior. - Highlights: • Ordered magnetic moment of Ni{sup 2+} increases in an applied magnetic field. • Composition variations detected by electron microscopy. • Increase in magnetic moment can be explained by presence of composition variations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transmission electron microscopy for the evaluation and optimization of crystal growth

The crystallization of protein samples remains the most significant challenge in structure determination by X-ray crystallography. Here, the effectiveness of transmission electron microscopy (TEM) analysis to aid in the crystallization of biological macromolecules is demonstrated. It was found that the presence of well ordered lattices with higher order Bragg spots, revealed by Fourier analysis of TEM images, is a good predictor of diffraction-quality crystals. Moreover, the use of TEM allowed (i) comparison of lattice quality among crystals from different conditions in crystallization screens; (ii) the detection of crystal pathologies that could contribute to poor X-ray diffraction, including crystal lattice defects, anisotropic diffraction and crystal contamination by heavy protein aggregates and nanocrystal nuclei; (iii) the qualitative estimation of crystal solvent content to explore the effect of lattice dehydration on diffraction and (iv) the selection of high-quality crystal fragments for microseeding experiments to generate reproducibly larger sized crystals. Applications to X-ray free-electron laser (XFEL) and micro-electron diffraction (microED) experiments are also discussed.

Stevenson, Hilary P.↗

On Change in the Silicon Crystal Structure Implanted with Hydrogen Ions during Annealing Based on Three-Crystal X-Ray Diffractometry Data

In this paper, we present the results of a three-crystal X-ray diffractometry (XRD) study of the state of a disturbed layer formed in silicon crystals by implantation of hydrogen ions with energies of 100 + 200 + 300 keV and a total dose of 2 × 10{sup 16} cm{sup –2} during the subsequent heat exposure in the temperature range from 200 to 1100°C. Here, X-ray studies were performed in the three-crystal XRD scheme when the sample under consideration operates as a second stationary crystal with various fixed angular detuning α from the Bragg position while the third (perfect) crystal-analyzer sweeps the angular distribution of radiation diffracted by the second crystal. Based on a comparison of the shape of diffraction and diffuse maxima for the samples under study, a qualitative conclusion about a significant transformation of radiation defects at post-implantation annealing was derived.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Determination of Residual Stress in Quenched and Cold-Compressed 7050 Aluminum Alloy T-Section Forgings by the Contour Method and Neutron Diffraction

Residual stresses were determined through the thickness of quenched and quenched followed by cold compression 7050 aluminum alloy T-section forgings using the contour method and neutron diffraction. 7050 T-section forgings are used for the manufacture of the connecting joints of wing and fuselage. Inevitably high residual stresses are introduced during the quenching process of 7050 T-section forgings, which could be reduced by cold compression to overcome the effect of residual stress on machining deformation. The longitudinal residual stresses obtained by the two techniques achieved good agreement in both trend and magnitude in both the quenched and quenched followed by cold compression 7050 T-section forgings. The stress-free lattice spacing of Al(311), the Bragg reflection used for the neutron measurements, was obtained from a 5-mm slice using the plane-stress condition, and its variation through the thickness is insignificant in both the quenched specimen and quenched followed by cold compression specimen. A comparison of the residual stresses in the quenched specimen and quenched followed by cold compression specimen showed significant changes in range of residual stresses from (− 304, 262 MPa) induced by quenching process to (− 125, 142 MPa) due to 3% cold compression. The percentage reduction in residual stress in the quenched specimen due to 3% cold compression was (46, 59%).

36 MATERIALS SCIENCE↗

Ultra-precision fabrication of 500 mm long and laterally graded Ru/C multilayer mirrors for X-ray light sources

X-ray mirrors are needed for beam shaping and monochromatization at advanced research light sources, for instance, free-electron lasers and synchrotron sources. Such mirrors consist of a substrate and a coating. The shape accuracy of the substrate and the layer precision of the coating are the crucial parameters that determine the beam properties required for various applications. In principal, the selection of the layer materials determines the mirror reflectivity. A single layer mirror offers high reflectivity in the range of total external reflection, whereas the reflectivity is reduced considerably above the critical angle. A periodic multilayer can enhance the reflectivity at higher angles due to Bragg reflection. Here, the selection of a suitable combination of layer materials is essential to achieve a high flux at distinct photon energies, which is often required for applications such as microtomography, diffraction, or protein crystallography. This contribution presents the current development of a Ru/C multilayer mirror prepared by magnetron sputtering with a sputtering facility that was designed in-house at the Helmholtz-Zentrum Geesthacht. The deposition conditions were optimized in order to achieve ultra-high precision and high flux in future mirrors. Input for the improved deposition parameters came from investigations by transmission electron microscopy. The X-ray optical properties were investigated by means of X-ray reflectometry using Cu- and Mo-radiation. The change of the multilayer d-spacing over the mirror dimensions and the variation of the Bragg angles were determined. The results demonstrate the ability to precisely control the variation in thickness over the whole mirror length of 500 mm thus achieving picometer-precision in the meter-range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stoichiometry optimization of homoepitaxial oxide thin films using x-ray diffraction.

Homoepitaxial SrTiO{sub 3} thin films grown by molecular beam epitaxy are analyzed using high-resolution x-ray diffraction and transmission electron microscopy. Measured 00L x-ray scans from stoichiometric and nonstoichiometric films are compared with calculations that account for the effects of film thickness, lattice parameter, fractional site occupancy, and an offset between film and substrate at the interface. It is found that thickness fringes, commonly observed around Bragg reflections even in stoichiometric homoepitaxial SrTiO{sub 3} films, arise from a film/substrate interface offset. Transmission electron microscopy studies confirm the presence of strain at those homoepitaxial interfaces that show an offset in x-ray diffraction. The consequences for stoichiometry optimization of homoepitaxial films using high-resolution x-ray diffraction and the quality of regrown oxide interfaces are discussed.

36 MATERIALS SCIENCE↗

Resonant diffraction in stishovite near the K absorption edge of silicon

The X-ray resonant diffraction in a stishovite crystal near the K absorption edge of silicon (E{sub K} = 1839 eV) is studied theoretically. For such a long wavelength, the only possible Bragg reflection is the 100 reflection, which is forbidden by the space group of the crystal. It can be excited solely due to anisotropy of the X-ray scattering amplitude. The crystal symmetry is used to determine the polarization and azimuthal dependence of the reflection intensity. Since this reflection is single, it can be detected upon diffraction from a powder, which substantially widens the possibilities of investigations. The numerical calculations of the energy dependences of the forbidden reflection intensity and the absorption coefficient demonstrate that the dipole-quadrupole, quadrupole-quadrupole, and dipole-octupole contributions to the resonant diffraction and absorption are small and that the dipole-dipole contribution is the most important one.

36 MATERIALS SCIENCE↗

Design and construction of a compact, high-repetition-rate ultrafast electron diffraction instrument

We present the design and performance of a compact ultrafast electron diffraction instrument. The diffractometer provides a means of examining time-resolved ultrafast dynamical properties of solids. The system’s utilization is discussed in terms of instrument parameters and diffraction data from selected condensed matter samples. Here, the difractometer’s performance is highlighted in terms of detection sensitivity, instrumental temporal resolution, and the electron beam transverse coherence length. Following specific details of the construction, we present a practical discussion of parameters such as repetition rate and provide advice on general construction approaches for laboratory-based, keV ultrafast electron diffractometers. In addition, design guidance for constructing a compact electron gun source that is well-suited for studying diffraction from hard condensed matter is given. A unique data acquisition scheme, utilizing high laser repetition rates, is presented.

47 OTHER INSTRUMENTATION↗

Second-order Bragg gratings in single-mode chalcogenide fibres

Bragg gratings with a second-order resonance wavelength in the near-IR spectral region have been inscribed into single-mode chalcogenide (As{sub 2}S{sub 3}) glass fibre by a He - Ne laser beam using a configuration typical of Bragg grating fabrication in germanosilicate fibre, with the use of a phase mask that ensures effective diffraction of the writing light into the +1 and -1 orders. The spectra of the inscribed gratings show no resonances due to cladding mode excitation because the cladding material is photosensitive. (fibre optics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-of-Flight Bragg Scattering from Aligned Stacks of Lipid Bilayers using the Liquids Reflectometer at the Spallation Neutron Source

Time-of-flight (TOF) neutron diffraction experiments on aligned stacks of lipid bilayers using the horizontal Liquids Reflectometer at the Spallation Neutron Source are reported. Specific details are given regarding the instrumental setup, data collection and reduction, phase determination of the structure factors, and reconstruction of the one-dimensional neutron scattering length density (NSLD) profile. The validity of using TOF measurements to determine the one-dimensional NSLD profile is demonstrated by reproducing the results of two well known lipid bilayer structures. The method is then applied to show how an antimicrobial peptide affects membranes with and without cholesterol.

Lipid Bilayers↗

The early development of neutron diffraction: science in the wings of the Manhattan Project

Early neutron diffraction experiments performed in 1944 using the first nuclear reactors are described. Although neutron diffraction was first observed using radioactive decay sources shortly after the discovery of the neutron, it was only with the availability of higher intensity neutron beams from the first nuclear reactors, constructed as part of the Manhattan Project, that systematic investigation of Bragg scattering became possible. Remarkably, at a time when the war effort was singularly focused on the development of the atomic bomb, groups working at Oak Ridge and Chicago carried out key measurements and recognized the future utility of neutron diffraction quite independent of its contributions to the measurement of nuclear cross sections. Ernest O. Wollan, Lyle B. Borst and Walter H. Zinn were all able to observe neutron diffraction in 1944 using the X-10 graphite reactor and the CP-3 heavy water reactor. Subsequent work by Wollan and Clifford G. Shull, who joined Wollan’s group at Oak Ridge in 1946, laid the foundations for widespread application of neutron diffraction as an important research tool.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging the Progression of Radiolytic Damage in Molecular Crystals with Scanning Nanobeam Electron Diffraction

Almost every electron microscopy experiment is fundamentally limited by radiation damage. Nevertheless, little is known about the onset and progression of radiolysis in beam-sensitive materials. Here we apply ambient-temperature scanning nanobeam electron diffraction to record simultaneous dual-space movies of organic and organometallic nanocrystals at sequential stages of beam-induced radiolytic decay. We show that the underlying mosaic of coherently diffracting domains undergoes internal rearrangement as a function of accumulating electron fluence, causing the intensities of some associated Bragg reflections to fade nonmonotonically. Furthermore, we demonstrate that repeated irradiation at a single probe position leads to the isotropic propagation of delocalized radiolytic damage well beyond the direct footprint of the incident beam. We refer to these expanding tides of amorphization as “impact craters.”

59 BASIC BIOLOGICAL SCIENCES↗

Machine-learning-assisted automation of single-crystal neutron diffraction

Neutron scattering is a powerful but expensive technique to study materials and discover new matter. Advanced detector technology has significantly improved the efficiency of neutron experiments, increasing the complexity of neutron data reduction and analysis. Machine learning (ML) brings new directions for neutron diffraction data reduction and experiment operation. Here, this work presents an ML-assisted data reduction and analysis method for precise recognition of Bragg peaks and the corresponding regions of interest; it can then automatically screen and align a measured crystal using the recognized peaks, and subsequently plan and optimize the data collection with user-provided information and uncertainty quantification values of detected peaks. This method shows robust performance in different complex sample environments and enables automated single-crystal neutron diffraction.

47 OTHER INSTRUMENTATION↗

X-ray refraction-contrast computed tomography images using dark-field imaging optics

If an x-ray beam containing internal information derived from sample soft tissue is incident upon a Laue-case analyzer, the beam will subsequently split into a forwardly diffracted beam and a separate diffracted beam. Using these beams acquired simultaneously, a refraction-contrast computed tomography (CT) imaging system for biomedical use with lower radiation dose can be easily realized, and has a high depicting capability on the soft tissues compared with conventional x-ray CT based on absorption contrast principles. In this paper, we propose an imaging system using dark-field imaging for CT measurement based on a tandem system of Bragg- and Laue-case crystals with two two-dimensional detectors, along with a data-processing method to extract information on refraction from the measured entangled intensities by use of rocking curve fitting with polynomial functions. Reconstructed images of soft tissues are presented and described.

07 ISOTOPE AND RADIATION SOURCES↗