Search NASA⌕ Search

SEARCH · Search NASA

Results for “cable systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications, including high strength-to-weight ratio, and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods. This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel during cure. In order to perform ultrasonic scans in-situ during cure, the system needed to be able to operate at oven temperatures up to 200 °C. There are no commercially available ultrasonic scanning systems that can operate continuously at these temperatures, so an enclosure was fabricated to insulate the ultrasonic system in the curing oven. The enclosure housed a MISTRAS® motorized X-Y raster scanner and contact transducer (Olympus® X2002). The Olympus® X2002 contact transducer is a continuous high-temperature delay line transducer with a center frequency of 2.25 MHz. In order to prevent the inside of the enclosure from reaching high temperatures, a sparge pipe inside the cooling enclosure was connected to a liquid nitrogen (LN2) tank outside of the oven via insulated hoses. The cooling system was automatically controlled by a temperature controller that was programmed to open a solenoid valve along the hose at 31 ℃ and close at 28 ℃ inside the cooling enclosure. When the solenoid valve was open, LN2 would flow from the LN2 tank and vaporize prior to reaching cooling enclosure. A U-shaped sparge pipe had holes drilled along its length to uniformly introduce cold nitrogen gas into the cooling enclosure. This prevented the motors from ever reaching the maximum desired operating temperature of 38 ℃. In the bottom of the enclosure, the tool plate was placed with the composite facing the outside of the enclosure, exposing it to the temperatures of the oven. The tool plate was 63.5 mm thick borosilicate glass, which was chosen for its low ultrasonic attenuation and moderate thermal conductivity. A thin layer of ultrasonic couplant was placed on the tool plate. The transducer sent and received ultrasonic waves through the tool plate into the composite. A MISTRAS® Remote UT System performed all wave generation, analog to digital conversion, and data acquisition and processing. The transducer was connected directly to the Remote UT System via a high-temperature BNC cable (CD International, RG-316). Polyimide insulated copper wire was used to connect the scanner to a 2-axis motor drive, which was connected to the Remote UT System. The motor drive and Remote UT System were located outside the industrial oven. A diagram of the ultrasonic system is shown in Figure 1. Figure 1: Diagram of ultrasonic in-situ defect detection system. In this study, a porosity gradient was introduced into the carbon fiber reinforced polymer (CFRP) composite through a misfit of the part and caul plate. A 24-ply quasi-isotropic ([0/90, ±45]12S) composite panel was laid up using Newport® AS4C-M/NB321 out-of-autoclave (OOA) plain weave (PW) prepreg (42% resin content, 195 g/m2). The first 16 plies were 203 mm × 203 mm. Ply drops were incorporated into the panel by decreasing the length of plies 17-24. The sizes of each ply are included in Table 1. All plies were centered along their length (x-axis) creating a trapezoidal type cross-section. Table 1: Ply sizes Plies Length (mm) Width (mm) 1-16 203 203 17-18 102 203 19-20 85 203 21-22 68 203 23-24 51 203 A 15-5 stainless steel caul plate (Size: 203 × 203 × 1.2 mm) was placed on the laminate. The composite and caul plate were vacuum bagged to the tool plate. Per the product datasheet, Newport 321 can be cured between 121 °C and 149 °C, depending on service temperature, with a hold for 90-120 minutes. Based on prior thermal testing of the cooling enclosure, the desired composite temperature cycle could be attained when the air temperature of the oven was ramped to 160 °C at a rate of 1.7 °C/min with a 3 hour hold. The extended hold was not necessary to cure the composite, but did allow for additional scans at the cure temperature during preliminary testing. The composite panel was under vacuum pressure for the entire cure cycle. Under vacuum, the caul plate deformed causing high and low pressure regions. The low-pressure regions formed high porosity in the composite part. The ultrasonic data collected showed that the inspection system was able to monitor the evolution of porosity within the composite throughout the cure cycle. Fifty scans of a 203 mm × 51 mm (8 in. × 2 in.) area of the composite were completed throughout the cure cycle. The scan speed was set to 43 mm/s in the x-direction and 36 mm/s in the y-direction, with a 1.0 mm/pixel resolution in both directions. Each scan took approximately five minutes to complete. Figure 2 shows C-scan amplitude data (top view) from one scan during the cure cycle. The color map indicates the maximum amplitude (%) measured with a time gate that contains reflections from the back surface (furthest from the transducer in contact with the caul plate) of the composite. Because porosity in the composite increases the ultrasonic attenuation in the composite part, a higher amplitude (red) indicates low porosity and a lower amplitude (blue) indicates high porosity. The regions where the caul plate was applying increased pressure (center and ends of the panel) resulted in reduced porosity, whereas the ply drop regions had reduced pressure and thus had higher porosity. Figure 2: Amplitude C-scan (top view) of OOA composite from one scan during the 160 °C temperature hold. Higher amplitude (red) indicates low porosity. Lower amplitude (blue) indicates high porosity. A B-scan is a two-dimensional image plotting the ultrasonic signals from a single y-position at every x-location of the composite panel. The travel time (μs) of the ultrasonic wave (representing the through-thickness location) is plotted along the y-axis, and the ultrasonic wave signal is represented as a contour map. Based on the B-scan data, the location of the defects with respect to the composite thickness was able to be determined. The ply drop regions had high porosity near the front (tool plate) surface of the composite (Figure 3). Figure 3: B-scan (cross-section view) of OOA composite from one scan during the 160 °C temperature hold. Using the data obtained from amplitude C-scans and B-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized with high spatial resolution. This paper will discuss the evolution of porosity content in the OOA composite during cure. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

Tyler B. Hudson↗

Neurolab Biotelemetry System (NBS)

This system was developed by the Sensors 2000! Program (S2K!) at Ames Research Center for the E132 STS-90 Neurolab Shuttle mission experiment to monitor 12 untethered adult male rats housed in the Research Animal Habitat Facility (RAHF). The system monitored the animals for body temperature, heart rate, and activity, and stored the data on board for up to 21 days for downloading after landing. The principal investigator's monitoring requirements were accomplished integrating a combination of both commercial and in-house developed hardware and software, including an off-the-shelf implantable telemetry transmitter and receiver system. In addition, a custom-developed antenna system was incorporated into the RAHF cages to perform the unique function of near-field radio-frequency (rf) measurement in the metal cages. This system proved the ability to perform wireless physiological measurements in very non-ideal circumstances using existing habitats and cabling without interfering with other experiment or shuttle systems. S2K! is continuing development on a custom telemetry transmitter and receiver system which will expand measurement capabilities.

Schonfeld, J.↗

Fault-Tolerant Local-Area Network

Local-area network (LAN) for computers prevents single-point failure from interrupting communication between nodes of network. Includes two complete cables, LAN 1 and LAN 2. Microprocessor-based slave switches link cables to network-node devices as work stations, print servers, and file servers. Slave switches respond to commands from master switch, connecting nodes to two cable networks or disconnecting them so they are completely isolated. System monitor and control computer (SMC) acts as gateway, allowing nodes on either cable to communicate with each other and ensuring that LAN 1 and LAN 2 are fully used when functioning properly. Network monitors and controls itself, automatically routes traffic for efficient use of resources, and isolates and corrects its own faults, with potential dramatic reduction in time out of service.

Morales, Sergio↗

Preliminary photovoltaic arc-fault prognostic tests using sacrificial fiber optic cabling.

Through the New Mexico Small Business Assistance Program, Sandia National Laboratories worked with Sentient Business Systems, Inc. to develop and test a novel photovoltaic (PV) arc-fault detection system. The system operates by pairing translucent polymeric fiber optic sensors with electrical circuitry so that any external abrasion to the system or internal heating causes the fiber optic connection to fail or detectably degrade. A periodic pulse of light is sent through the optical path using a transmitter-receiver pair. If the receiver does not detect the pulse, an alarm is sounded and the PV system can be de-energized. This technology has the unique ability to prognostically determine impending failures to the electrical system in two ways: (a) the optical connection is severed prior to physical abrasion or cutting of PV DC electrical conductors, and (b) the polymeric fiber optic cable melts via Joule heating before an arc-fault is established through corrosion. Three arc-faults were created in different configurations found in PV systems with the integrated fiber optic system to determine the feasibility of the technology. In each case, the fiber optic cable was broken and the system annunciated the fault.

Johnson, Jay Dean↗

Quench detection using Hall sensors in high-temperature superconducting CORC ® -based cable-in-conduit-conductors for fusion applications

Advanced magnet systems for fusion applications would greatly benefit from the use of high-temperature superconductors (HTS). These materials allow fusion magnets to operate at higher magnetic fields, allowing for more compact fusion machines, and allow for operation at elevated temperatures, enabling demountable coils that provide access for maintenance of the fusion reactor. Quench detection remains a major challenge in the protection of HTS magnets that are vulnerable to localized conductor burnout due to their low quench propagation velocities. One of the methods explored is the use of Hall sensors that are incorporated in or near the magnet terminations that can detect local field variations that occur as a result of current redistribution within the conductor to bypass a hotspot within the magnet winding. This method is potentially well suited for Cable in Conduit Conductors, such as those made from Conductor on Round Core (CORC) cables, in which sub-cables containing HTS tapes are connected to the terminations at a low resistance. Here, to demonstrate the technique, a CORC ® triplet consisting of three sub-cables, rated for 4 kA operation at 77 K, was manufactured and Hall sensors were used to measure local field variations next to the terminations due to current redistribution between the cables. The Hall response was compared to voltages that developed over the cables and terminations as a local hotspot was applied to different cables in the triplet. It was found that the Hall sensors were faster and more sensitive than voltage contact measurements and were able to reliably detect current redistribution of only a few amperes caused by a hotspot, well before the triplet exceeded its critical current. The method also allowed the detection of heater-induced hotspots during high ramp rates of 2 kA s<:sup>–1 relevant for fusion applications. Hall sensors have a distinct benefit of being less sensitive to inductive pickup of AC interference compared to voltage contact measurements that make quench detection through voltage measurements in magnets especially challenging. The method can also be used for diagnostic measurements of current redistribution caused by other sources such as inhomogeneous current injection from faulty joints, or localized conductor damage. The Hall sensors are likely capable of detecting the onset of a quench that may occur a far distance away from the sensor location, presenting a breakthrough in HTS quench detection that potentially removes one of the remaining barriers to reliable operation of large HTS magnet systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Acoustic MEMS Sensor Array for Quench Detection of CICC Superconducting Cables

Here, a novel quench detection method using micro-electro-mechanical system (MEMS) sensor technology has been investigated in use for high temperature superconducting (HTS) conductors such REBCO tape cables. The sensor array along a superconducting cable, such as a cable-in-conduit-conductor (CICC), is installed in a cooling channel. It will allow sensitive and quick detection for a local quench of a superconducting cable. This work has confirmed that a quench of a single REBCO tape can be detected in liquid nitrogen by a MEMS piezoelectric microphone sensor. The quench detection design utilizing a MEMS sensor array method is discussed for the case of a toroidal field (TF) magnets of a fusion Tokamak device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time-Domain Vortex Induced Vibration Modeling of Reference Dynamic Power Cable for the Gulf of Maine

Vortex-induced vibration (VIV) is a phenomenon known to decrease the fatigue life of dynamic power cables used in floating offshore wind systems through increased bending loading cycles. A variety of modeling solutions have been proposed to study this, but none enable fully-coupled simulations leveraging open-source tools. To address this, a time-domain VIV model has been successfully implemented into the open-source mooring dynamics model MoorDyn. The semi-empirical VIV model describes a lift force acting on segments of a flexible cylinder, making it well suited for implementation into MoorDyn. The new capability successfully predicted the frequencies and magnitudes of strain in both steady and oscillating flows when compared to the original validation results and matched peak spectral response when compared to experimental results, verifying successful implementation. MoorDyn with VIV was then leveraged to simulate a 15 MW floating turbine with a dynamic power cable in the Gulf of Maine using OpenFAST for six return periods of combined wind, wave, and current conditions. Increased curvature and tension fluctuations in higher flow speeds were observed when simulating VIV. Maximum tensions and curvatures also increased, with the 500 year conditions violating the curvature factor of safety of 2.0. These results highlight the importance of considering VIV when designing dynamic power cables for the Gulf of Maine, and indicate that cost effective mitigation strategies should be explored for the area. They also demonstrate the utility of this new modeling capability, which provides the first open-source tool for fully coupled time-domain floating offshore wind simulations with dynamic power cable VIV.

17 WIND ENERGY↗

MSFC MXER Tether Study

This viewgraph presentation provides an overview of the proposed Momentum-eXchange/Electrodynamic Reboost (MXER) space hardware system. The tether system would be position cart-wheeling cables above the Earth and then, rotating like a giant sling, would capture spacecraft or payloads from space shuttles in low Earth orbits and launch them into higher orbits. This study focuses on system validation and structural design issues for MXER. Topics examined include: tether facility design, ED tether system, payload capture/catch mechanism, payload accomodations assembly (PAA), PAA rendezvous capability, and PAA capability to correct tether misthrows.

Polsgrove, Tara↗

Ion Thruster Used to Propel the Deep Space 1 Spacecraft to Comet Encounters

The NASA Solar Electric Propulsion Technology Applications Readiness (NSTAR) Project provided a xenon ion propulsion system to the Deep Space 1 (DS1) spacecraft to validate the propulsion system as well as perform primary propulsion for asteroid and comet encounters. The On-Board Propulsion Branch of the NASA Glenn Research Center at Lewis Field developed engineering model versions of the 30-cm-diameter ion thruster and the 2.5-kW power processor unit (PPU). Glenn then transferred the thruster and PPU technologies to Hughes Electron Dynamics and managed the contract, which supplied two flight sets of thrusters and PPU s to the Deep Space 1 spacecraft and to a ground-based life verification test at the Jet Propulsion Laboratory (JPL). In addition to managing the DS1 spacecraft development, JPL was responsible for the NSTAR Project management, thruster life tests, the feed system, diagnostics, and propulsion subsystem integration. The ion propulsion development team included NASA Glenn, JPL, Hughes Electronics, Moog Inc., and Spectrum Astro Inc. The overall NSTAR subsystem dry mass, including thruster, PPU, controller, cables, and the xenon storage and feed system, is 48 kg. The mass of the xenon stored onboard DS1 was about 81 kg, and the spacecraft wet mass was approximately 500 kg.The DS1 spacecraft was launched on October 24, 1998, and on July 29, 1999, it flew within 16 miles of the small asteroid Braille (formerly 1992KD) at a relative speed of 35,000 mph. As of November 1999, the ion propulsion system had performed flawlessly for nearly 149 days of thrusting. NASA has approved an extension to the mission, which will allow DS1 to continue thrusting to encounters with two comets in 2001. The DS1 optical and plasma diagnostic instruments will be used to investigate the comet and space environments. The spacecraft is scheduled to fly past the dormant comet Wilson- Harrington in January 2001 and the very active comet Borrelly in September 2001, at which time approximately 500 days of ion engine thrusting will have been completed.

Sovey, James S.↗

Mitigation of Electromagnetic Pulse (EMP) Effects from Short-Pulse Lasers and Fusion Neutrons

Our research focused on obtaining a fundamental understanding of the source and properties of EMP at the Titan PW(petawatt)-class laser facility. The project was motivated by data loss and damage to components due to EMP, which can limit diagnostic techniques that can be used reliably at short-pulse PW-class laser facilities. Our measurements of the electromagnetic fields, using a variety of probes, provide information on the strength, time duration, and frequency dependence of the EMP. We measure electric field strengths in the 100's of kV/m range, durations up to 100 ns, and very broad frequency response extending out to 5 GHz and possibly beyond. This information is being used to design shielding to mitigate the effects of EMP on components at various laser facilities. We showed the need for well-shielded cables and oscilloscopes to obtain high quality data. Significant work was invested in data analysis techniques to process this data. This work is now being transferred to data analysis procedures for the EMP diagnostics being fielded on the National Ignition Facility (NIF). In addition to electromagnetic field measurements, we measured the spatial and energy distribution of electrons escaping from targets. This information is used as input into the 3D electromagnetic code, EMSolve, which calculates time dependent electromagnetic fields. The simulation results compare reasonably well with data for both the strength and broad frequency bandwidth of the EMP. This modeling work required significant improvements in EMSolve to model the fields in the Titan chamber generated by electrons escaping the target. During dedicated Titan shots, we studied the effects of varying laser energy, target size, and pulse duration on EMP properties. We also studied the effect of surrounding the target with a thick conducting sphere and cube as a potential mitigation approach. System generated EMP (SGEMP) in coaxial cables does not appear to be a significant at Titan. Our results are directly relevant to planned short-pulse ARC (advanced radiographic capability) operation on NIF.

36 MATERIALS SCIENCE↗

High-Pressure, High-Temperature Thermal Hydraulic Test Facility for Nuclear-Renewable Hybrid Energy System Studies; Facility Design Description and Status Report

A high-pressure, high-temperature water flow loop has been designed at Idaho National Laboratory (INL) for deployment in the INL Dynamic Energy Transport and Integration Laboratory (DETAIL) within the Energy Systems Laboratory (ESL) D100 northwest high bay. This loop is the first of three thermally coupled flow loops that will comprise the Advanced Reactor Technology Integral System Test (ARTIST) facility. The ARTIST facility will ultimately include a high temperature helium loop and a liquid salt loop, in addition to the PWR loop. The high-pressure water loop will operate at Pressurized Water Reactor (PWR) conditions. It will support experimental research on nuclear-renewable hybrid energy systems as well as advanced reactor technology topics. Within DETAIL, the water flow loop will also serve as a thermal energy source, emulating a reactor system. The loop will be thermally integrated with co-located energy systems including a thermal energy transport loop, thermal energy storage system, and a 25 kW high-temperature electrolysis system for hydrogen production. DETAIL will include additional energy systems such as an integrated microgrid and renewable energy systems including solar photovoltaics. The electrically heated flow loop will be dynamically controlled to simulate nuclear fuel behavior under normal and off-normal operating conditions. DETAIL will be designed for characterization of complex system dynamics. The various components will be interfaced with Digital Real-Time Simulators for supervisory control and dynamic simulation of complete systems. The design and assembly of the high-pressure water flow loop and supporting systems has been subdivided into two Phases. Phase 1, which will be completed by the end of FY17, includes installation of cable trays and supports, electrical conduit, DI water system, drain lift station and the concrete pad for the chiller located outside of the laboratory. Phase 2 includes the detailed design and final assembly of the flow loop, supporting structures and personnel platforms, the chiller and associated piping. As of September, 2017, the final detailed design of the flow loop is complete. Funding for Phase 2 procurement, assembly, system operability checkout, shakedown testing and initial operation of the flow loop is requested for FY18.

42 ENGINEERING↗

Follow-on cable coupling lightning test, volume 1

A redesigned solid rocket motor test article was subjected to simulated lightning strikes. This test was performed to evaluate the effects of lightning strike to the redesigned motor and Space Transportation System. The purpose of the test was to evaluate the performance of systems tunnel design changes when subjected to the lightning discharges. The goal of the design changes was to reduce lightning induced coupling to cables within the systems tunnel. The test article was subjected to several different amounts and kinds of discharges. Changes in coupling levels detected during the tests are recorded. The dominant mode of coupling appears to be caused by the diffusion of the magnetic fields through the system tunnel covers. The results from bond strap integrity testing showed that 16 of 18 bond straps survived. Design change evaluations showed that coupling reduction ranged from 0 to 36 decibels for each type of cable. The type of cable has less effect on coupling than does strike location and strike levels. Recommendations for design changes are made.

Danforth, Richard↗

CJ concept for advanced aircraft wiring

The techniques and hardware are described which were developed for facilitating the use of flexible flat conductor cable (FFCC) in commercial air transports. The system was designed as an evolutionary transition from the current round wire harnessing to the use of FFCC harnesses. The equipment discussed includes the pressure crimp barrel designed for terminating FFCC, reel-fed applicator, cable connectors and adaptors, and equipment racks.

Redslob, J.↗

Emergency Flight Control Using Computer-Controlled Thrust

Propulsion Controlled Aircraft (PCA) systems are digital electronic control systems undergoing development to provide limited maneuvering ability through variations of individual engine thrusts in multiple-engine airplanes. Provide landing capability when control surfaces inoperable. Incorporated on existing and future airplanes that include digital engine controls, digital flight controls, and digital data buses, adding no weight for additional hardware to airplane. Possible to handle total failure of hydraulic system, depending on how surfaces respond to loss of hydraulic pressure, and broken control cables or linkages. Future airplanes incorporate data from Global Positioning System for guidance to any suitable emergency runway in world.

Burcham, Frank W., Jr.↗

Fly-by-Wireless Update

The presentation reviews what is meant by the term 'fly-by-wireless', common problems and motivation, provides recent examples, and examines NASA's future and basis for collaboration. The vision is to minimize cables and connectors and increase functionality across the aerospace industry by providing reliable, lower cost, modular, and higher performance alternatives to wired data connectivity to benefit the entire vehicle/program life-cycle. Focus areas are system engineering and integration methods to reduce cables and connectors, vehicle provisions for modularity and accessibility, and a 'tool box' of alternatives to wired connectivity.

Studor, George↗

Cables and connectors: A compilation

A compilation is presented that reflects the uses, adaptation, and maintenance plus service, that are innovations derived from problem solutions in the space R and D programs, both in house and by NASA and AEC contractors. Data cover: (1) technology revelant to the employment of flat conductor cables and their adaptation to and within conventional systems, (2) connectors and various adaptations, and (3) maintenance and service technology, and shop hints useful in the installation and care of cables and connectors.

Source record↗

Loss-of-Control-Inhibitor Systems for Aircraft

Systems to provide improved tactile feedback to aircraft pilots are being developed to help the pilots maintain harmony between their control actions and the positions of aircraft control surfaces, thereby helping to prevent loss of control. A system of this type, denoted a loss-of-control-inhibitor system (LOCIS) can be implemented as a relatively simple addition to almost any pre-existing flight-control system. The LOCIS concept offers at least a partial solution to the problem of (1) keeping a pilot aware of the state of the control system and the aircraft and (2) maintaining sufficient control under conditions that, as described below, have been known to lead to loss of control. Current commercial aircraft exhibit uneven responses of primary flight-control surfaces to aggressive pilot control commands, leading to deterioration of pilots ability to control their aircraft. In severe cases, this phenomenon can result in loss of control and consequent loss of aircraft. For an older aircraft equipped with a purely mechanical control system, the loss of harmony between a pilot s command action and the control- surface response can be attributed to compliance in the control system (caused, for example, by stretching of control cables, flexing of push rods, or servo-valve distortion). In a newer aircraft equipped with a fly-by-wire control system, the major contributions to loss of harmony between the pilot and the control surfaces are delays attributable to computer cycle time, control shaping, filtering, aliasing, servo-valve distortion, and actuator rate limiting. In addition, a fly-by-wire control system provides no tactile feedback that would enable the pilot to sense such features of the control state as surface flutter, surface jam, position limiting, actuator rate limiting, and control limiting imposed by the aircraft operational envelope. Hence, for example, when a pilot is involved in aggressive closed-loop maneuvering, as when encountering a wake-vortex upset on final landing approach, the control-surface delay can lead to loss of control. Aggressive piloting can be triggered and exacerbated by control-system anomalies, which the pilot cannot diagnose because of the lack of symptoms caused by the absence of feedback through the controls. The purpose served by a LOCIS is to counteract these adverse effects by providing real-time feedback that notifies the pilot that the aircraft is tending to lag the pilot s commands. A LOCIS (see figure) includes cockpit control input-position sensors, control-surface output-position sensors, variable dampers (for example, shock absorbers containing magneto-rheological fluids such that the damping forces can be varied within times of the order of milliseconds by varying applied magnetic fields) attached to the cockpit control levers, electromagnet coils to apply the magnetic fields, and feedback control circuits to drive the electromagnet coils. The feedback control gains are chosen so that the current applied to each electromagnet coil results in a damping force that increases in a suitable nonlinear manner (e.g., exponentially) with the difference between the actual and commanded positions of the affected control surface. The increasing damping force both alerts the pilot to the onset of a potentially dangerous situation and resists the pilot s effort to command a control surface to change position at an excessive rate

AHarrah, Ralph C.↗