Search NASA⌕ Search

SEARCH · Search NASA

Results for “coherence measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Growth of organized flow coherent motions within a single-stream shear layer: 4D-PTV measurements

Abstract This study investigates the evolution of a single-stream shear layer (SSSL) originating from a wall boundary layer past a backward-facing step. Utilizing a time-resolved 3D-Particle Tracking Velocimetry (4D-PTV) technique, we track the trajectories of fluorescent particles to gain insight into the flow characteristics of the SSSL. A compact water tunnel facility ( $$\textrm{Re}_\tau =1\,240$$ Re τ = 1 240 ) is fabricated to obtain an SSSL with a perpendicular slow entrainment stream past the separation edge. A hybrid interpolation approach that combines ensemble binning and Gaussian weighting is implemented to derive minimally filtered mean and instantaneous lower- and higher-order flow field parameters. Spanwise-dominant coherent motion accompanied by finer flow scales is observed to grow due to flow entrainment through “nibbling” actions of small-scale vortices, “engulfing” by large-scale vortices, and vortex pairing events. Furthermore, the non-zero-speed stream edge grows relatively faster than the zero-speed stream edge, showing a strong asymmetry in mixing composition across a mixing layer. The SSSL reaches self-similarity at a streamwise distance of $$\approx 55\,\theta _{0}$$ ≈ 55 θ 0 , where $$\theta _0$$ θ 0 is the initial momentum thickness from the separation edge, i.e., considerably shorter than reported in previous studies. A literature comparison of growth rate parameters raises intriguing questions regarding a potential inclusive growth scaling unifying the free shear layers. A turbulent kinetic energy (TKE) budget analysis reveals a negative production region immediately downstream of the separation edge attributed to a large positive streamwise gradient of streamwise velocity. In the self-similar region, the phase-averaged flow mapping demonstrates a larger concentration of turbulence production rate around the outer edges of spanwise vortices, specifically at the intersection of braids and vortices. Furthermore, a spatial separation exists in the regions of peak production and dissipation rates within the vortex core region favoring dissipation. The braids exhibit a larger concentration of turbulence diffusion rates, indicating their function as a conduit for exchanging turbulence between neighboring coherent motions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radar Thickness Measurements over the Southern Part of the Greenland Ice Sheet

We performed ice thickness measurements over the southern part of the Greenland ice sheet during June and July 1993. We used an airborne coherent radar depth sounder for these measurements. The radar was operated from a NASA P-3 aircraft equipped with GPS receivers. Radar data were collected in conjunction with laser altimeter and microwave altimeter measurements of ice surface elevation. This report provides radio echograms and thickness profiles from data collected during 1993.

Chuah, Teong Sek↗

Characteristics of 13.9 GHz radar scattering from oil films on the sea surface

Aircraft microwave scatterometer measurements are presented, which were made in 1979 as part of a project to study the response of a number of active and passive microwave and optical remote sensors to an oil-covered sea surface conducted by NASA Langley Research Center. A 13.9-GHz Doppler scatterometer with a fan beam antenna and coherent detection was used to measure radar backscatter as a function of incidence angle. The radar scattering signature of the clear surface and signatures of the surface covered with various crude oil films are compared. Reductions in Ku band microwave backscatter up to 14 dB are observed for both treated and untreated LaRosa and Murban crude oil films deposited on the sea surface. Maximum Ku band sensitivity to the effects of the oil in terms of differential scatter is observed in the 25-35 deg incidence angle region.

Johnson, J. W.↗

Application of Spectral Analysis Techniques in the Intercomparison of Aerosol Data. Part II: Using Maximum Covariance Analysis to Effectively Compare Spatiotemporal Variability of Satellite and AERONET Measured Aerosol Optical Depth

Moderate Resolution Imaging SpectroRadiometer (MODIS) and Multi-angle Imaging Spectroradiomater (MISR) provide regular aerosol observations with global coverage. It is essential to examine the coherency between space- and ground-measured aerosol parameters in representing aerosol spatial and temporal variability, especially in the climate forcing and model validation context. In this paper, we introduce Maximum Covariance Analysis (MCA), also known as Singular Value Decomposition analysis as an effective way to compare correlated aerosol spatial and temporal patterns between satellite measurements and AERONET data. This technique not only successfully extracts the variability of major aerosol regimes but also allows the simultaneous examination of the aerosol variability both spatially and temporally. More importantly, it well accommodates the sparsely distributed AERONET data, for which other spectral decomposition methods, such as Principal Component Analysis, do not yield satisfactory results. The comparison shows overall good agreement between MODIS/MISR and AERONET AOD variability. The correlations between the first three modes of MCA results for both MODIS/AERONET and MISR/ AERONET are above 0.8 for the full data set and above 0.75 for the AOD anomaly data. The correlations between MODIS and MISR modes are also quite high (greater than 0.9). We also examine the extent of spatial agreement between satellite and AERONET AOD data at the selected stations. Some sites with disagreements in the MCA results, such as Kanpur, also have low spatial coherency. This should be associated partly with high AOD spatial variability and partly with uncertainties in satellite retrievals due to the seasonally varying aerosol types and surface properties.

aerosols↗

Demonstration of universal control between non-interacting qubits using the Quantum Zeno effect

The Zeno effect occurs in quantum systems when a very strong measurement is applied, which can alter the dynamics in non-trivial ways. Despite being dissipative, the dynamics stay coherent within any degenerate subspaces of the measurement. Here we show that such a measurement can turn a single-qubit operation into a two- or multi-qubit entangling gate, even in a non-interacting system. We demonstrate this gate between two effectively non-interacting transmon qubits. Our Zeno gate works by imparting a geometric phase on the system, conditioned on it lying within a particular non-local subspace. These results show how universality can be generated not only by coherent interactions as is typically employed in quantum information platforms, but also by Zeno measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Doppler Lidar Motion-Correction Wind Profiles (DLMCPROF-WIND) Value-Added Product Report

Wind speed and direction, together with pressure, temperature, and relative humidity, are the most fundamental atmospheric state parameters. Accurate measurement of these parameters is crucial for numerical weather prediction. Vertically resolved wind measurements in the atmospheric boundary layer are particularly important for modeling pollutant and aerosol transport. The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility currently operates several scanning coherent Doppler lidar (DL) systems that provide accurate height-resolved measurements of wind speed and direction. These instruments operate in the near infrared (IR;1.5 microns) and provide range-resolved measurements of radial velocity, attenuated aerosol backscatter, and signal-to-noise ratio (SNR). The systems are operated using a fixed scan schedule consisting of plan position indicator (PPI) or Doppler Beam-Swing (DBS) scans. PPI scans are performed by scanning the beam in azimuth while maintaining a fixed elevation angle, and DBS scans are similar but typically also include a vertical beam. Radial velocity data from these scans are processed to yield profiles of wind speed direction. For stationary ground-based deployments, the Doppler Lidar Horizontal Wind Profiles (DLPROF-WIND) Value-Added-Product (VAP) provides height- and time-resolved measurements of the winds (Newsom and Krishnamurthy 2022). For operation on a moving platform, modifications to the existing DLPROF-WIND VAP are required to compensate for the effects of the platform motion. This report describes a parallel VAP, DLMCPROF-WIND, that was developed for computing motion-compensated wind profiles from ARM Doppler lidar data acquired during the Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) campaign, when the lidar was deployed on the German icebreaker Polarstern.

54 ENVIRONMENTAL SCIENCES↗

A Novel Technique for Distributed Measuring of Strain in the Vadose Zone

Characterizing water content and pressure changes in the vadose zone is important to understanding a variety of geologic processes, ranging from permeability, to evapotranspiration, and aquifer recharge. Changes in water content, or pressure, cause strain in the solid porous medium of the vadose zone, and it is possible that measuring those strains could be used a characterization tool. The Coherence-length-gated Microwave Photonics Interferometry (CMPI) technique measures strain at high resolution along many intervals defined by pairs of reflectors distributed along an optical fiber. This technique has recently been developed at Clemson University, and it has the spatial, and temporal resolution to characterize the strains that are expected to occur with hydrologic changes in the vadose zone. However, the technique has never been used to measure strain in porous media, so its capabilities remain uncertain. The objective of this thesis is to evaluate the ability of using CMPI to measure strain changes in the vadose zone. The research approach consists of conducting laboratory tests using a column filled with sand that was subjected to changes in water content and pressure. An optical fiber with CMPI reflectors was deployed in a high surface area ribbon and used to measure strain along the axis of the column. The column was made from 8-inch, Schedule 40 PVC pipe (75 cm tall, 20 cm inner diameter) and filled with medium-grained sand (K = 2.5x10-6 m/s, porosity = 0.28, Coefficient of Uniformity = 2, van Genuchten (n = 4.34 and  = 0.00039 m-1), Young’s Modulus = 18 – 47 MPa). Five pressure and four temperature sensors attached to probes inserted into the wall. The optical fiber includes five reflectors spaced 10 cm apart on the inside and outside of the column along the vertical axis. Strain measurements are made between pairs of reflectors. The reflectors are created in 250-micron-diameter acrylate-coated single mode Corning SMF28e+ optical fiber using a femtosecond laser. The optical fiber was laminated between two pieces of polyester film creating a large surface area to transfer strain from the porous media to the optical fiber. The experiments were conducted by filling the column from the bottom or infiltrating water from the top. The water was allowed to equilibrate to room temperature prior to each test in order to limit thermoelastic strain. Five injection tests with a rate of 250 ml/min and three infiltration tests at varying rates were conducted, and the results show patterns of strain and pressure are generally similar. Hydrologic conditions define three zones based on the pressure magnitude and distribution. 1.) Ambient Zone where the pressure heads are quasi-static and the pressure gradient is roughly unity (head gradient of zero). This is the uppermost zone and is characterized by negative pressures. 2.) Transition Zone where the pressures increase from ambient to zero, are changing relatively rapidly and the pressure gradient is relatively steep (pressure head gradients of 2). The Transition zone is 10 to 15 cm thick. 3.) Positive Pressure Zone where the pressure is positive, the rate of change is slower than in the transition zone and the gradient is flatter (pressure head gradient 1.1 to 1.2). This is the lowest zone in the column. Injection of water causes the pressure to increase and the three zones to move upward. The Transition zone moves at a rate of approximately 0.0002 m/s +/- .00005, according to analyses of pressure profiles. This is the same as the average velocity of the water calculated as volumetric flux/effective porosity =5.4x10-5 m/s/0.28. Strain signals in the range of 10s  were observed with a noise level of generally less than 0.1  (signal to noise ratio of greater than 100) during injection and drainage. The spatial and temporal distributions of strain caused by injection depend on the location of the moving pressure zones. The locations of the different pressure zones were determined from pressure profiles at different times and these data were transferred to strain time series. This showed that strain in the Ambient pressure zone is either unchanged or slightly compressive, whereas strain in Transition zone is tensile and roughly proportional to the pressure change, and strain ranges from tensile to compressive in the Positive Pressure zone. In general, the strain is variable at the top of the Positive Pressure zone, but it appears to be consistently tensile lower in the zone. The spatial distribution of strain causes three distinct stages in the strain times series measured between pairs of CMPI reflectors. The strain is unchanged or slightly compressive during Stage 1, it increases (positive strain is tensile) approximately linearly at a rate of 0.02 to 0.03 μ/s during the Stage 2, and then flattens out in Stage 3. The strain increases again during Stage 4 of the time series. The pressure also changes in stages. It is unchanged during Stage 1 and then increases relatively rapidly at a rate of between 4 and 10 Pa/s during Stage 2 and continues to increase during Stages 3 and 4, but at a rate slightly slower than during Stage 2 (from 2.5 to 3.5 Pa/s). The rates of pressure and strain change are consistent with basic analyses. The rate of pressurization is similar to the calculated velocity of flow in the saturated zone, and this is similar to the measured velocity of the strain increase. The ratio of the pressurization rate and strain rate during Stage 2 (2.5 (Pa/s) /0.03 (μ/s)) is 80 MPa, which is approximately equal to the upper range expected considering the uniaxial compression and the Young’s Modulus of the sand. An interesting effect occurs when the upper surface of the sand becomes saturated. Significant compression (several 10s of ) occurs as the pressure and saturation increase at the upper surface. Compression occurs throughout the column, but the effect is greatest at the top of the column. The rate of compression is fastest slightly before ponding occurs, but it slows markedly and nearly stops when water starts to accumulate at the surface (ponding). This effect reverses when the surface of the sand is drained, resulting in tension throughout the column. The compression caused by this effect can be as large or larger than the tensile strain that accumulated during filling. This effect was unexpected because increasing pressure is normally associated with tensile strain. Nevertheless, this effect was observed consistently in all tests where the pressure changes at the upper surface, including tests where water was injected from below or infiltrated from above. This effect behaves as if the pore pressure at the upper surface of the sand exerts a normal force on the boundary (increasing pore pressure exerts a downward compression on the boundary). The results of these laboratory experiments indicate that CMPI can measure strain caused by fluid pressure changes in the vadose zone with a signal to noise ratio of 100 or more. Injection and drainage cause a strain signal that is complex, but repeatable. The magnitudes of the strain signal are consistent with magnitudes that are expected based on poroelastic calculations using independently measured properties of the sand. These results indicate that the CMPI technique with an optical fiber laminated in a polyester ribbon generates data that represent the strain distribution during hydrologic processes of imbibition and drainage in variably saturated sand. This suggests that distributed strain measurements using CMPI could be a viable approach for evaluating processes in the vadose zone, laying the groundwork for future field implementation.

47 OTHER INSTRUMENTATION↗

TPSAS-NF1676L-11931-DND

Researchers at NASA Langley Research Center have developed an efficient, high repetition rate, pulsed, 2-µm coherent DIAL/IPDA transmitter for CO2 measurements. This transmitter will be employed to measure atmospheric CO2 profiles (by DIAL) initially from a ground platform, and then measure both the atmospheric CO2 profiles (by DIAL) and column densities (by IPDA) from an airborne platform with the potential for measuring CO2 column density from a space-borne platform. The transmitter consists of a pulsed Q-switched ring-cavity Ho:YLF laser operating at 2.05 micron, being pumped by a Tm:fiber laser. The repetition rate can be adjusted from a few hundred Hz to 10 kHz with corresponding energy of 25 to 1 mJ, respectively. This transmitter can be used for direct or coherent detection of CO2 from ground, air or space-borne platform, as it is capable of providing required energy/repetition rate even from space platform. This presentation will describe the details of the injection-seeded highrepetition rate 2-micron transmitter and demonstrate its flexibility for direct or coherent detection of CO2.

Upendra N Singh↗

Superradiance and Exciton Delocalization in Perovskite Quantum Dot Superlattices

Achieving superradiance in solids is challenging due to fast dephasing processes from inherent disorder and thermal fluctuations. Perovskite quantum dots (QDs) are an exciting class of exciton emitters with large oscillator strength and high quantum efficiency, making them promising for solid-state superradiance. However, a thorough under-standing of the competition between coherence and dephasing from phonon scattering and energetic disorder is currently unavailable. Here, we present an investigation of exciton coherence in perovskite QD solids using temperature-dependent photoluminescence line width and lifetime measurements. Our results demonstrate that excitons are coherently delocalized over 3 QDs at 11 K in superlattices leading to superradiant emission. Scattering from optical phonons leads to the loss of coherence and exciton localization to a single QD at temperatures above 100 K. Further, at low temperatures, static disorder and defects limit exciton coherence. These results highlight the promise and challenge in achieving coherence in perovskite QD solids.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Erbium quantum memory platform with long optical coherence via back-end-of-line deposition on foundry-fabricated photonics

Realizing scalable quantum interconnects necessitates the integration of solid-state quantum memories with foundry photonics processes. While prior photonic integration efforts have relied upon specialized, laboratory-scale fabrication techniques, this work demonstrates the monolithic integration of a quantum memory platform with low-loss foundry photonic circuits via back-end-of-line deposition. We deposited thin films of titanium dioxide (Ti⁢O 2 ) doped with erbium (Er) onto silicon nitride nanophotonic waveguides and studied Er optical coherence at subkelvin temperatures with photon echo techniques. Furthermore, we suppressed optical dephasing through ex-situ oxygen annealing and optimized measurement conditions, which yielded an optical coherence time of 64 μ⁢s (a 5-kHz homogeneous linewidth) and slow spectral diffusion of 27 kHz over 4 ms, results that are comparable to state-of-the-art Er nanophotonic devices. Combined with second-long electron spin lifetimes and demonstrated electrical control of Er emission, our findings establish Er:Ti⁢O 2 on foundry photonics as a manufacturable platform for ensemble and single-ion quantum memories.

Electro-optic effects↗

Simultaneous Ocean Wave Measurements by the Jason and Topex Satellites, With Buoy and Model Comparisons

The verification phase of the Jason-1 satellite altimeter mission presents a unique opportunity for comparing near-simultaneous, independent satellite measurements. We here examine simultaneous significant wave height measurements by the Jason-1 and Topex/Poseidon altimeters. These data are also compared with in-situ measurements from deep-ocean buoys and with predicted wave heights from the Wave Watch 111 operational model. The rms difference between Jason and Topex wave heights is 21 cm, and this can be further lowered by application of median filters to reduce high-frequency noise. This noise is slightly larger in the Jason dataset, amounting to about 7 cm rms for frequencies above 0.05 Hz, which is the frequency at which the coherence between Topex and Jason measurements drops to zero. The probability density function for Jason shows a dearth of small waves relative to Topex. Buoy comparisons confirm that this problem lies with the Jason measurements. The buoy comparisons confirm previous reports that Topex wave heights are roughly 5% smaller than buoy measurements for waves between 2 and 5m; Jason heights in general are 2.7% smaller than Topex. Spurious dips in the Topex density function for 3- and 6-meter waves, a problem that has existed since the beginning of the mission, can be solved by waveform retracking..

Ray, Richard D.↗

Simultaneous Ocean Wave Measurements by the JASON and TOPEX Satellites, With Buoy and Model Comparisons

The verification phase of the Jason-1 satellite altimeter mission presents a unique opportunity for comparing near-simultaneous, independent satellite measurements. We here examine simultaneous significant wave height measurements by the Jason-1 and Topex/Poseidon altimeters. These data are also compared with in-situ measurements from deep-ocean buoys and with predicted wave heights from the WaveWatch 111 operational model. The rms difference between Jason and Topex wave heights is 28 cm, and this can be lowered by half through improved outlier editing and filtering of high-frequency noise. Noise is slightly larger in the Jason dataset, exceeding Topex by about 7 cm rms at frequencies above 0.05 Hz, which is the frequency at which the coherence between Topex and Jason measurements drops to zero. Jason wave heights are more prone to outliers, especially during periods of moderate to high backscatter. Buoy comparisons confirm previous reports that Topex wave heights are roughly 5% smaller than buoy measurements for waves between 2 and 5m; Jason heights in general are 3% smaller than Topex. Spurious dips in the Topex density function for 3- and 6-meter waves, a problem that has existed since the beginning of the mission, can be solved by waveform retracking.

Ray, R. D.↗

The role of coherent structures in the generation of noise for subsonic jets

Acoustic measurements were made in the 'near' (r/D 60, x/D 60) field for high Reynolds number (184,000 to 262,000) axisymmetric cold air jets exhausting at atmospheric pressure. These measurements were in conjunction with an investigation which characterized the large scale coherent structure in the flow field of Mach number 0.6 to 0.8 jets. Natural jets as well as artificially excited jets were studied. Directivity plots were made for both natural jets and jets excited at various frequencies. Overall noise radiated by the jets reached a maximum value around 30 deg from the jet axis. However, individual frequencies emitted maximum sound pressure level at different angles from the jet axis. As the angle from the jet axis increased, the spectra of the noise shifted to higher frequencies.

Morrison, G. L.↗

The GSFC 20 and 30 GHz millimeter wave propagation experiment

The preliminary results of the Goddard Space Flight Center Millimeter Wave Experiment, flown aboard ATS-6 to investigate the propagation characteristics of earth-space communications links at 20 and 30 GHz, are discussed. The spacecraft transmitters operate through spot beam (2 deg) or continental coverage (6 by 9 deg) antenna systems. The transmitted signals consist of a set of nine tones spaced out to 1440 MHz to allow measurement of wideband attenuation and coherence through precipitation. Initial data on precipitation depolarization and attenuation effects indicate that attenuation effects will exert the stronger influence on the design of frequency re-use communications systems in the 20 GHz region. The use of four ground terminals separated by 30 to 78 km to reduce the effects of rain attenuation has been successful, with improvement approaching the theoretical maximum demonstrated for five events. Preliminary results on the use of on-beam radar measurements for predicting rain attenuation are encouraging.

Ippolito, L. J.↗

Advances in High Energy Solid-State Pulsed 2-Micron Lidar Development for Ground and Airborne Wind, Water Vapor and CO2 Measurements

NASA Langley Research Center has a long history of developing 2-micron lasers. From fundamental spectroscopy research, theoretical prediction of new materials, laser demonstration and engineering of lidar systems, it has been a very successful program spanning around two decades. Successful development of 2-micron lasers has led to development of a state-of-the-art compact lidar transceiver for a pulsed coherent Doppler lidar system for wind measurement with an unprecedented laser pulse energy of 250 millijoules in a rugged package. This high pulse energy is produced by a Ho:Tm:LuLiF laser with an optical amplifier. While the lidar is meant for use as an airborne instrument, ground-based tests were carried out to characterize performance of the lidar. Atmospheric measurements will be presented, showing the lidar's capability for wind measurement in the atmospheric boundary layer and free troposphere. Lidar wind measurements are compared to a balloon sonde, showing good agreement between the two sensors. Similar architecture has been used to develop a high energy, Ho:Tm:YLF double-pulsed 2-micron Integrated Differential Absorption Lidar (IPDA) instrument based on direct detection technique that provides atmospheric column CO2 measurements. This instrument has been successfully used to measure atmospheric CO2 column density initially from a ground mobile lidar trailer, and then it was integrated on B-200 plane and 20 hours of flight measurement were made from an altitude ranging 1500 meters to 8000 meters. These measurements were compared to in-situ measurements and National Oceanic and Atmospheric Administration (NOAA) airborne flask measurement to derive the dry mixing ratio of the column CO2 by reflecting the signal by various reflecting surfaces such as land, vegetation, ocean surface, snow and sand. The lidar measurements when compared showed a very agreement with in-situ and airborne flask measurement. NASA Langley Research Center is currently developing a triple-pulsed 2-micron Integrated Differential Absorption Lidar (IPDA) instrument for simultaneous measurement of water vapor and carbon-dioxide column density measurement from an air-borne platform. This presentation will give an overview of the 2 decades of 2-micron coherent and direction detection of laser/lidar development at NASA Langley Research Center and will present the ground and airborne wind and column CO2 measurement intercomparison with in-situ, balloon and flask measurements.

Singh, Upendra N.↗

High Efficiency End-Pumped Ho:Tm:YLF Disk Amplifier

Space based coherent lidar for global wind measurement requires an all solid state laser system with high energy, high efficiency and narrow linewidth that operates in the eye safe region. A Q-switched, diode pumped Ho:Tm:YLF 2 micrometer laser with output energy of as much as 125 mJ at 6 Hz with an optical-to-optical efficiency of 3% has been reported. Single frequency operation of the laser was achieved by injection seeding. The design of this laser is being incorporated into NASA's SPARCLE (SPAce Readiness Coherent Lidar Experiment) wind lidar mission. Laser output energy ranging from 500 mJ to 2 J is required for an operational space coherent lidar. We previously developed a high energy Ho:Tm:YLF master oscillator and side pumped power amplifier system and demonstrated a 600-mJ single frequency pulse at a repetition rate of 10 Hz. Although the output energy is high, the optical-to-optical efficiency is only about 2%. Designing a high energy, highly efficient, conductively cooled 2-micrometer laser remains a challenge. In this paper, the preliminary result of an end-pumped amplifier that has a potential to provide a factor 3 of improvement in the system efficiency is reported.

Yu, Jirong↗

CARS Temperature and Species Concentration Measurements in a Supersonic Combustor with Normal Injection

The dual-pump coherent anti-Stokes Raman spectroscopy (CARS) method was used to measure temperature and the absolute mole fractions of N2, O2 and H2 in a supersonic combustor. Experiments were conducted in the NASA Langley Direct-Connect Supersonic Combustion Test Facility. CARS measurements were performed at the facility nozzle exit and at three planes downstream of fuel injection. Processing the CARS measurements produced maps of the mean temperature, as well as quantitative N2 and O2 and qualitative H2 mean mole fraction fields at each plane. The CARS measurements were also used to compute correlations between fluctuations of the different simultaneously measured parameters. Comparisons were made between this 90 degree angle fuel injection case and a 30 degree fuel injection case previously presented at the 2004 Reno AIAA Meeting.

Tedder, S. A.↗