Search NASA⌕ Search

SEARCH · Search NASA

Results for “computerized procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

A benchmark concept for simulation in radiographic testing

The new standard ISO 17636–2:2013 “NDT of welds: Radiographic testing - Part 2: X- and gamma ray techniques with digital detectors” describes a complex procedure for film replacement by phosphor imaging plates and digital detector arrays. RT modeling software should consider these detector types, X-ray film, and the standard requirements for image quality. Practitioners expect the same visibility of image quality indicators (IQI) in the simulated radiographs as in the experimental exposures. The proposed benchmark test is based on the comparison of experimental radiographs taken at BAM with modeled ones of participants. The experimental setup and the determination of the equivalent penetrameter sensitivity (EPS) as described in the procedure of ASTM E 746 are used for quantitative evaluation of the achievable contrast sensitivity for step hole IQIs as considered in Annex B of ISO 17636–2. System classification data for Computed Radiography (CR) and film systems will be provided by BAM according to ISO 11699–1 for selected film systems and according to ASTM E 2446 for selected CR systems. The classification of films and digital detectors is based on the measurement of the dose response function, the basic spatial resolution (SR{sub b}) of the image, and the measured image noise, which depends on the detector efficiency, the quantum statistics, and the detector fixed pattern noise.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Poster - 32: Atlas Selection for Automated Segmentation of Pelvic CT for Prostate Radiotherapy

Atlas based-segmentation has recently been evaluated for use in prostate radiotherapy. In a typical approach, the essential step is the selection of an atlas from a database that the best matches of the target image. This work proposes an atlas selection strategy and evaluate it impacts on final segmentation accuracy. Several anatomical parameters were measured to indicate the overall prostate and body shape, all of these measurements obtained on CT images. A brute force procedure was first performed for a training dataset of 20 patients using image registration to pair subject with similar contours; each subject was served as a target image to which all reaming 19 images were affinity registered. The overlap between the prostate and femoral heads was quantified for each pair using the Dice Similarity Coefficient (DSC). Finally, an atlas selection procedure was designed; relying on the computation of a similarity score defined as a weighted sum of differences between the target and atlas subject anatomical measurement. The algorithm ability to predict the most similar atlas was excellent, achieving mean DSCs of 0.78 ± 0.07 and 0.90 ± 0.02 for the CTV and either femoral head. The proposed atlas selection yielded 0.72 ± 0.11 and 0.87 ± 0.03 for CTV and either femoral head. The DSC obtained with the proposed selection method were slightly lower than the maximum established using brute force, but this does not include potential improvements expected with deformable registration. The proposed atlas selection method provides reasonable segmentation accuracy.

60 APPLIED LIFE SCIENCES↗

Multiple Bifurcated Covered Self-Expanding Metallic Stents for Complex Tracheobronchial Fistulas or Stenosis

Objective: We aimed to determine the safety and feasibility of bifurcated covered self-expanding stents for the treatment of complex tracheobronchial fistulas or stenosis. Methods: Twenty-eight patients were treated by multiple bifurcated covered airway stents (Micro-Tech Co. Ltd., Nanjing, China), including 18 cases of gastrobronchial or gastrotracheal fistula, 6 cases of bronchopleural fistula and 4 cases of severe tracheobronchial stenosis. The large bifurcated covered stent was placed at the main carina, and the small stents were inserted into primary right carina or secondary left carina. Clinical and imaging data were retrospectively analyzed. Results: Stents were successfully inserted in 27 patients at the first attempt. In total, 29 large bifurcated covered stents, 27 small bifurcated covered stents and 5 small bifurcated covered single-plugged stents were inserted. All patients with fistula could resume eating without coughing after the procedure. No perioperative death or severe complications occurred. Two patients underwent stent removal due to intolerance of stenting; the clinical success rate was 93% (26/28). Nineteen complications were found in 12 patients; 8 patients needed stent removal or replacement, for a major complication rate of 29% (8/28). Eight patients underwent successful stent removal due to complications. Fifteen patients died of tumors and one patient died of pulmonary infection. The median survival was 33 months. Fistula recurrence was found in one patient 5 months after stenting, and second small bifurcated covered stent was inserted. Conclusions: Multiple bifurcated covered metallic stenting is effective and safe for complex tracheobronchial fistulas or stenosis, with good symptom palliation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Wetting Behavior and Reactivity of Molten Silicon with h-BN Substrate at Ultrahigh Temperatures up to 1750 °C

For a successful implementation of newly proposed silicon-based latent heat thermal energy storage systems, proper ceramic materials that could withstand a contact heating with molten silicon at temperatures much higher than its melting point need to be developed. In this regard, a non-wetting behavior and low reactivity are the main criteria determining the applicability of ceramic as a potential crucible material for long-term ultrahigh temperature contact with molten silicon. In this work, the wetting of hexagonal boron nitride (h-BN) by molten silicon was examined for the first time at temperatures up to 1750 °C. For this purpose, the sessile drop technique combined with contact heating procedure under static argon was used. The reactivity in Si/h-BN system under proposed conditions was evaluated by SEM/EDS examinations of the solidified couple. It was demonstrated that increase in temperature improves wetting, and consequently, non-wetting-to-wetting transition takes place at around 1650 °C. The contact angle of 90° ± 5° is maintained at temperatures up to 1750 °C. The results of structural characterization supported by a thermodynamic modeling indicate that the wetting behavior of the Si/h-BN couple during heating to and cooling from ultrahigh temperature of 1750 °C is mainly controlled by the substrate dissolution/reprecipitation mechanism.

36 MATERIALS SCIENCE↗

An Anatomically Validated Brachial Plexus Contouring Method for Intensity Modulated Radiation Therapy Planning

Purpose: To develop contouring guidelines for the brachial plexus (BP) using anatomically validated cadaver datasets. Magnetic resonance imaging (MRI) and computed tomography (CT) were used to obtain detailed visualizations of the BP region, with the goal of achieving maximal inclusion of the actual BP in a small contoured volume while also accommodating for anatomic variations. Methods and Materials: CT and MRI were obtained for 8 cadavers positioned for intensity modulated radiation therapy. 3-dimensional reconstructions of soft tissue (from MRI) and bone (from CT) were combined to create 8 separate enhanced CT project files. Dissection of the corresponding cadavers anatomically validated the reconstructions created. Seven enhanced CT project files were then automatically fitted, separately in different regions, to obtain a single dataset of superimposed BP regions that incorporated anatomic variations. From this dataset, improved BP contouring guidelines were developed. These guidelines were then applied to the 7 original CT project files and also to 1 additional file, left out from the superimposing procedure. The percentage of BP inclusion was compared with the published guidelines. Results: The anatomic validation procedure showed a high level of conformity for the BP regions examined between the 3-dimensional reconstructions generated and the dissected counterparts. Accurate and detailed BP contouring guidelines were developed, which provided corresponding guidance for each level in a clinical dataset. An average margin of 4.7 mm around the anatomically validated BP contour is sufficient to accommodate for anatomic variations. Using the new guidelines, 100% inclusion of the BP was achieved, compared with a mean inclusion of 37.75% when published guidelines were applied. Conclusion: Improved guidelines for BP delineation were developed using combined MRI and CT imaging with validation by anatomic dissection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-20: Commissioning and Acceptance Testing of the C-Rad CatalystHD Surface Imaging System

Introduction: With the increasing use of surface-based, nonionizing image-guided radiotherapy (IGRT) systems, a comprehensive set of clinical acceptance and commissioning procedures are needed to ensure correct functionality and proper clinical integration. Although TG-147 provides a specific set of parameters, measurement methodologies have yet to be described. The aim of this study was to provide a comprehensive overview of the commissioning and acceptance analysis performed for the C-Rad CatalystHD imaging system. Methods and Materials: Methodology for the commissioning and acceptance of the C-Rad CatalystHD imaging system was developed using commercially available clinical equipment. Following TG-147 guidelines, the following tests were performed: integration of peripheral equipment, system drift, static spatial reproducibility and localization accuracy, static end-to-end analysis, static rotational accuracy, dynamic spatial accuracy, dynamic temporal accuracy, dynamic radiation delivery and a comprehensive end-to-end analysis. Results: The field of view (FOV) of the CatalystHD was 105×109×83 cm3 in the lateral, longitudinal and vertical directions. For thermal equilibrium and system drift, a thermal drift of 1.0mm was noted. A 45 min warmup time is recommended if the system has been shut off an extended period of time (>24 hours) before the QA procedure to eliminate any thermal drift. Spatial reproducibility was found to be 0.05±0.03 mm using a rigid phantom. For the static localization accuracy, system agreement with couch shifts was within 0.1±0.1 mm and positioning agreement with kV-CBCT was 0.16±0.10 mm. For static rotational accuracy, system agreement with a high precision rotational stage (0.01 deg precision) was within 0.10±0.07 deg. Dynamic spatial and temporal localization accuracy was found to be within 0.2±0.1 mm. Conclusion: A comprehensive commissioning and acceptance study was performed using commercially available phantoms and in-house methodologies to provide a performance evaluation of the CatalystHD imaging system.

60 APPLIED LIFE SCIENCES↗

TOWARD MORE REALISTIC ANALYTIC MODELS OF THE HELIOTAIL: INCORPORATING MAGNETIC FLATTENING VIA DISTORTION FLOWS

Both physical arguments and simulations of the global heliosphere indicate that the tailward heliopause is flattened considerably in the direction perpendicular to both the incoming flow and the large-scale interstellar magnetic field. Despite this fact, all of the existing global analytical models of the outer heliosheath's magnetic field assume a circular cross section of the heliotail. To eliminate this inconsistency, we introduce a mathematical procedure by which any analytically or numerically given magnetic field can be deformed in such a way that the cross sections along the heliotail axis attain freely prescribed, spatially dependent values for their total area and aspect ratio. The distorting transformation of this method honors both the solenoidality condition and the stationary induction equation with respect to an accompanying flow field, provided that both constraints were already satisfied for the original magnetic and flow fields prior to the transformation. In order to obtain realistic values for the above parameters, we present the first quantitative analysis of the heliotail's overall distortion as seen in state-of-the-art three-dimensional hybrid MHD–kinetic simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Localised distributions and criteria for correctness in complex Langevin dynamics

Complex Langevin dynamics can solve the sign problem appearing in numerical simulations of theories with a complex action. In order to justify the procedure, it is important to understand the properties of the real and positive distribution, which is effectively sampled during the stochastic process. In the context of a simple model, we study this distribution by solving the Fokker–Planck equation as well as by brute force and relate the results to the recently derived criteria for correctness. We demonstrate analytically that it is possible that the distribution has support in a strip in the complexified configuration space only, in which case correct results are expected. -- Highlights: •Characterisation of the equilibrium distribution sampled in complex Langevin dynamics. •Connection between criteria for correctness and breakdown. •Solution of the Fokker–Planck equation in the case of real noise. •Analytical determination of support in complexified space.

97 MATHEMATICS AND COMPUTING↗

Characteristics Analysis of SGTR accidents under the Shutdown Conditions

The Steam Generator Tube Rupture (SGTR) accident is one of design basis accidents that could result in undesirable radiation release as it bypasses the containment. According to Ref. [1], SGTRs have been experienced in several nuclear power plants and Ulchin 4 of Korea is one of them. Basically, SGTR analysis assumes that it occurs at full power, the SGTR at Ulchin 4 in 2002, was in the shutdown condition. Therefore, the transient behavior was different from the cases in full power conditions and especially, the effectiveness of Emergency Operating Procedure (EOP) needs to be checked if it is also applicable to the shutdown conditions, because EOP is prepared for full power conditions. In this paper, we set up a MARS-KS code model for Ulchin 4 unit and simulated the SGTR accident for benchmarking the model to the actual plant behavior during the accident. And then, several case studies were done to investigate the consequence of SGTR and the effectiveness of the EOP, focusing on the amount of the primary to secondary discharge flow which was influenced by operator actions. At the end, we'll discuss about the EOP for the shutdown conditions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiation Exposure of Abdominal Cone Beam Computed Tomography

PurposeTo evaluate patients radiation exposure of abdominal C-arm cone beam computed tomography (CBCT).MethodsThis prospective study was approved by the institutional review board; written, informed consent was waived. Radiation exposure of abdominal CBCT was evaluated in 40 patients who underwent CBCT during endovascular interventions. Dose area product (DAP) of CBCT was documented and effective dose (ED) was estimated based on organ doses using dedicated Monte Carlo simulation software with consideration of X-ray field location and patients’ individual body weight and height. Weight-dependent ED per DAP conversion factors were calculated. CBCT radiation dose was compared to radiation dose of procedural fluoroscopy. CBCT dose-related risk for cancer was assessed.ResultsMean ED of abdominal CBCT was 4.3 mSv (95 % confidence interval [CI] 3.9; 4.8 mSv, range 1.1–7.4 mSv). ED was significantly higher in the upper than in the lower abdomen (p = 0.003) and increased with patients’ weight (r = 0.55, slope = 0.045 mSv/kg, p < 0.001). Radiation exposure of CBCT corresponded to the radiation exposure of on average 7.2 fluoroscopy minutes (95 % CI 5.5; 8.8 min) in the same region of interest. Lifetime risk of exposure related cancer death was 0.033 % or less depending on age and weight.ConclusionsMean ED of abdominal CBCT was 4.3 mSv depending on X-ray field location and body weight.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pulmonary Arteriovenous Malformations Embolized Using a Micro Vascular Plug System: Technical Note on a Preliminary Experience

AIMTo report our preliminary experience using a Micro Vascular Plug (MVP) deployed through a 2.8Fr micro-catheter for the treatment of pulmonary arteriovenous malformations (PAVMs) in a cohort of patients affected by Hereditary Haemorrhagic Telangiectasia (HHT).Materials and MethodsFour consecutive female patients (mean age 38.0 years; range 25–55 years) with PAVMs diagnosed on echocardiogram/bubble test and contrast-enhanced CT (CECT) underwent MVP embolization. One patient was symptomatic with recent transient ischaemic attack. Follow-up was undertaken at 1-month post-procedure with CECT to assess PAVMs permeability and MVP positioning and at 1-, 6-, and 12-month post-procedure, with echocardiography/bubble test and standard neurological history, to confirm absence of right-to-left shunts and recurrent symptoms.ResultsEight PAVMs were treated in 4 patients over 5 interventional sessions (mean 1.6 PAVMs per session). All PAVMs were simple, with mean feeding artery diameter of 4.25 mm. Eight 6.5 mm MVPs were deployed in total (one per lesion). Technical success was 100%. Mean procedural time and patient dose per session were 70 min (range 40–70 min) and 53418 mGy.cm{sup 2} (range 6113–101628 mGy.cm{sup 2}), respectively. No signs of reperfusion neither of MPV migration were noted at 1-month CECT follow-up. At early follow-up (mean 3.75 months; range 1–12 months), clinical success was 100% with no evidence of recurrent right-to-left shunt, and no neurological symptoms. No immediate or late complications were observed.ConclusionsMVP embolization of PAVMs appears technically feasible, safe, and effective at early follow-up. Further prospective studies are required to confirm long-term safety and efficacy of this promising technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-18A-05: Cone-Beam CT Reconstruction with Deformed Prior Image

Purpose: Prior image can be incorporated into image reconstruction process to improve the quality of on-treatment cone-beam CT (CBCT) from sparseview or low-dose projections. However, the deformation between the prior image and on-treatment CBCT are not considered in current prior image based reconstructions (e.g., prior image constrained compressed sensing (PICCS)). The purpose of this work is to develop a deformed-prior-imagebased- reconstruction strategy (DPIR) to address the mismatch problem between the prior image and target image. Methods: The deformed prior image is obtained by a projection based registration approach. Specifically, the deformation vector fields (DVF) used to deform the prior image is estimated through matching the forward projection of the prior image and the measured on-treatment projection. The deformed prior image is then used as the prior image in the standard PICCS algorithm. Simulation studies on the XCAT phantom was conducted to evaluate the performance of the projection based registration procedure and the proposed DPIR strategy. Results: The deformed prior image matches the geometry of on-treatment CBCT closer as compared to the original prior image. Using the deformed prior image, the quality of the image reconstructed by DPIR from few-view projection data is greatly improved as compared to the standard PICCS algorithm. The relative image reconstruction error is reduced to 11.13% in the proposed DPIR from 17.57% in the original PICCS. Conclusion: The proposed DPIR approach can solve the mismatch problem between the prior image and target image, which overcomes the limitation of the original PICCS algorithm for CBCT reconstruction from sparse-view or low-dose projections.

60 APPLIED LIFE SCIENCES↗

Beyond Annulus Size: Imaging for TAVR Planning

Purpose of Review: The aim of this article is to review the role of imaging in pre-procedural assessment prior to transcatheter aortic valve replacement (TAVR)—with a focus on relevant anatomic findings apart from the size of the aortic annulus. Recent Findings: Pre-procedure imaging prior to TAVR heavily emphasizes assessment of the aortic annulus for appropriate valve sizing, with computed tomography angiography (CTA) emerging as the test of choice due to its ability to assess not only the aortic annulus but also the thoracoabdominal aorta and peripheral vasculature. Some patients with underlying kidney disease may be at increased risk of renal dysfunction following contrast-enhanced CTA; however, alternate imaging techniques can be performed to mitigate this risk such as magnetic resonance imaging. Summary: Familiarity with underlying anatomic variability and pathology relevant to TAVR implantation in addition to annulus size, as well as imaging approaches in patients with renal dysfunction, will allow radiologists to better contribute to multidisciplinary discussion for potential TAVR candidates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A simple grand canonical approach to compute the vapor pressure of bulk and finite size systems

In this article we introduce a simple grand canonical screening (GCS) approach to accurately compute vapor pressures from molecular dynamics or Monte Carlo simulations. This procedure entails a screening of chemical potentials using a conventional grand canonical scheme, and therefore it is straightforward to implement for any kind of interface. The scheme is validated against data obtained from Gibbs ensemble simulations for water and argon. Then, it is applied to obtain the vapor pressure of the coarse-grained mW water model, and it is shown that the computed value is in excellent accord with the one formally deduced using statistical thermodynamics arguments. Finally, this methodology is used to calculate the vapor pressure of a water nanodroplet of 94 molecules. Interestingly, the result is in perfect agreement with the one predicted by the Kelvin equation for a homogeneous droplet of that size.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A BAYESIAN METHOD FOR THE ANALYSIS OF THE DUST EMISSION IN THE FAR-INFRARED AND SUBMILLIMETER

We present a method, based on Bayesian statistics, to fit the dust emission parameters in the far-infrared and submillimeter wavelengths. The method estimates the dust temperature and spectral emissivity index, plus their relationship, properly taking into account the statistical and systematic uncertainties. We test it on three sets of simulated sources detectable by the Herschel Space Observatory in the PACS and SPIRE spectral bands (70-500 {mu}m), spanning over a wide range of dust temperatures. The simulated observations are a one-component interstellar medium and two two-component sources, both warm (H II regions) and cold (cold clumps (CCs)). We first define a procedure to identify the better model, then we recover the parameters of the model and measure their physical correlations by means of a Markov Chain Monte Carlo algorithm adopting multi-variate Gaussian priors. In this process, we assess the reliability of the model recovery and of parameter estimation. We conclude that the model and parameters are properly recovered only under certain circumstances and that false models may be derived in some cases. We applied the method to a set of 91 starless CCs in an interarm region of the Galactic plane with low star formation activity, observed by Herschel in the Hi-GAL survey. Our results are consistent with a temperature-independent spectral index.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-296: Modulated Therapy Down Under: A Survey of IMRT & VMAT Physics Practice in Australia and New Zealand

Purpose: A comprehensive survey of Australasian radiation oncology physics departments was undertaken to capture a snapshot of current usage, commissioning and QA practices for intensity-modulated therapies. Methods: An online survey was developed and advertised to Australian and New Zealand radiation oncology physicists through the local college (ACPSEM) in April 2015. The survey consisted of 147 questions in total, covering IMRT, VMAT and Tomotherapy, and details specific to different treatment planning systems. Questions captured detailed information on equipment, policies and procedures for the commissioning and QA of each treatment technique. Results: 41 partial or complete responses were collected, representing 59 departments out of the 78 departments operational. 137 and 84 linacs from these departments were using IMRT and VMAT respectively, from a total 150 linacs. 100% and 78% of respondents were treating with IMRT and VMAT respectively. There are at least 8 different treatment planning systems being used for IMRT or VMAT, and large variations in all aspects of QA policies and procedures. 29 responses indicated 72 methods routinely used for pre-treatment QA, when breaking down by device and analysis type. Similar numbers of departments use field-by-field analysis compared to composite analysis (56% to 44%) while a majority use true gantry angle delivery compared to fixed gantry at 0° (72% to 28%). 19 different implementations of gamma index analysis parameters were reported from 33 responses. A follow-up one-day workshop to highlight the results, discuss the role of QA and share equipment-specific knowledge across users was conducted in November 2015. Conclusion: While IMRT and VMAT are almost universally available in Australasia, large variations in practice indicate a need for national or consensus guidelines.

60 APPLIED LIFE SCIENCES↗

Development of a Method for Measurement of Photonuclear-Reaction Cross Sections with the Aid of Simulated Quasimonoenergetic-Photon Spectra

A procedure for measuring photonuclear-reaction cross sections by employing the method of quasimonochromatization of the bremsstrahlung photon spectrum is developed. This procedure permits determining reaction cross sections via measuring the reaction yield at three fixed values of the electron energy. The procedure is equivalent to measuring the cross section in question for quasimonochromatic photons. Bremsstrahlung-photon spectra are obtained using state-of-the-art simulation means involving the GEANT4 code as applied to a specific experiment with allowance for its geometry, target thicknesses, electron-beam parameters, etc. The results obtained by simulating quasimonochromatic distributions of bremsstrahlung photons are presented for experiments at the LUE-8-5 linear electron accelerator of Institute for Nuclear Research (Moscow, Russian Academy of Sciences). These results are found to be in good agreement with the experimental energy distribution of the cross section for the reaction {sup 111}Cd(γ, γ') in the energy range between 5 and 8 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Patient Positioning Based on a Radioactive Tracer Implanted in Patients With Localized Prostate Cancer: A Performance and Safety Evaluation

Purpose: To evaluate the performance and safety of a radiation therapy positioning system (RealEye) based on tracking a radioactive marker (Tracer) implanted in patients with localized prostate cancer. Methods and Materials: We performed a single-arm multi-institutional trial in 20 patients. The iridium-192 ({sup 192}Ir)-containing Tracer was implanted in the patient together with 4 standard gold seed fiducials. Patient prostate-related symptoms were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Computed tomography (CT) was performed for treatment planning, during treatment, and after treatment to evaluate the migration stability of the Tracer. At 5 treatment sessions, cone beam CT was performed to test the positioning accuracy of the RealEye. Results: The Tracer was successfully implanted in all patients. No device or procedure-related adverse events occurred. Changes in IPSS scores were limited. The difference between the mean change in Tracer-fiducial distance and the mean change in fiducial-fiducial distance was -0.39 mm (95% confidence interval [CI] upper boundary, -0.22 mm). The adjusted mean difference between Tracer position according to RealEye and the Tracer position on the CBCT for all patients was 1.34 mm (95% CI upper boundary, 1.41 mm). Conclusions: Implantation of the Tracer is feasible and safe. Migration stability of the Tracer is good. Prostate patients can be positioned and monitored accurately by using RealEye.

62 RADIOLOGY AND NUCLEAR MEDICINE↗