Search NASA⌕ Search

SEARCH · Search NASA

Results for “conservative loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Performance Assessments of Demand Flexibility from Grid-Interactive Efficient Buildings: Issues and Considerations

This SEE Action Network report explains basic concepts and fundamental considerations for assessing the actual demand flexibility performance of buildings participating in demand flexibility programs and responding to time-varying retail rates. Demand flexibility is the capability of distributed energy resources (DERs) to adjust a building’s load profile across different timescales. Assessments determine the timing, location, quantity, and quality of grid services provided. The results can be used for financial settlements and to improve performance of demand flexibility, support its consideration in resource potential studies and electricity system planning, and contribute to cost-effectiveness evaluations. While practitioners and regulators regularly find opportunities to improve performance assessments of demand-related services, to a large degree current best practices are sufficient for basic service offerings as demand flexibility is implemented today. However, advances in assessment practices will be required in a future with grid-interactive efficient buildings (GEBs) that provide continuous demand flexibility by integrating multiple DERs and flexibility modes (load shed, load shift, modulate, and generate). Example practices include using new baseline constructs—including whether baselines are even required for certain building flexibility modes or configurations, deploying more advanced metering and analytics, further developing cybersecurity standards, improving communication standards for increased interoperability, and establishing performance metrics and assessment procedures for load modulation as it is more fully defined and implemented. This report provides information on prioritizing and designing performance assessment elements for demand flexibility programs and time-varying retail rates, assessment protocols, and research and development needs. Additional research sponsored by DOE’s Building Technologies Office offers more detailed technical information on assessing performance of demand flexibility, including definition of performance metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Efficiency Package for Tenant Fit-Out: Laboratory Testing and Validation of Energy Savings and Indoor Environmental Quality

Approximately 40% of the total U.S. office floor space of 1.5 billion sq.m (16 billion sq.ft.) is leased space occupied by tenants. Tenant fit-out presents a key opportunity to incorporate energy efficiency within the real estate business cycle. We designed a package of energy efficiency measures tailored to the scope of a tenant fit-out. This tenant fit-out package (TFP) includes advanced lighting and heating, ventilating and air-conditioning (HVAC) controls as core measures, with ceiling fans, automated shading, and plug load controls as additional optional measures. We conducted laboratory testing of six configurations of the package to evaluate energy savings, indoor environmental quality, and identify installation, commissioning, and operational issues. Combined savings for HVAC, lighting, and plug loads ranged from 33–40%. Lighting savings ranged from 69–83%, and HVAC savings from 20–40%. The laboratory testing also revealed some minor but tractable challenges with installation and commissioning of HVAC controls. Overall, the results demonstrate that significant savings can be realized in existing office buildings by incorporating relatively low-risk, proven measures at the time of a tenant fit-out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of different operating strategies of thermal energy storage with radiant cooling system

Thermal energy storage systems in building cooling applications have been explored extensively as a peak load-shifting technology. Thermal energy storage performance has been recognized and studied from an energy cost-savings point of view because of peak-valley price differences, but not many studies have been conducted from an energy savings viewpoint. This study experimentally investigates the performance of the energy storage-retrofitted to a ceiling-type radiant cooling system. To study the performance, a water-based storage system was designed and developed for an academic office building equipped with a radiant cooling system. The water in the storage tank was cooled to a certain storage temperature in the nighttime, and the same water was used during the daytime for meeting the cooling load. Different combinations of charging and discharging schedules were analyzed. The key objective of the study was to achieve energy savings and energy-cost savings simultaneously. This objective was accomplished by identifying the major factors contributing to the energy consumption of the storage-retrofitted cooling system and devising novel operating strategies, leading to an enhanced energy savings potential. Two operating strategies comprising 24 operating scenarios were compared and the storage was used to dispatch the load for 3 hours of the day as a full storage unit. Results showed that in hot and dry climate conditions, using the storage with the radiant cooling system offered energy savings of 3% to 14%. The energy-cost analysis was also performed using a time-of-day electricity tariff plan. The energy-cost savings varied from 17.5% to 22.4% for these operating scenarios.

25 ENERGY STORAGE↗

Low refractive index OLEDs for practical high-efficiency outcoupling. Final report

Improving OLED light extraction is a significant on-going challenge for the OLED lighting industry. The goal of this program was to explore the potential to improve internal light extraction in a manufacturable way by lowering the refractive index of the OLED stack through dilution with an electrically-inert, low refractive index molecule. We accomplished this goal, identifying a small molecule that can be co-evaporated in the hole transport layer of OLEDs at high loading to reduce the refractive index by 0.2-0.3 refractive index units without degrading charge transport. Implementing this dilution molecule in the hole transport layer of a range of single and multi-stack OLEDs, we demonstrated the ability to improve their internal light extraction by up to ~35% without increasing their drive voltage or reducing their operational lifetime. Importantly, these findings extend to state-of-the-art device architectures with proprietary OLED materials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Validation of Packaged RAD-AC HVAC System: Efficiency and Load Shifting via Electrochemical Regeneration of Liquid Desiccants

In this project, Mojave and SRI have demonstrated field validation and load shifting of liquid desiccant air conditioning systems with two liquid desiccant dedicated outdoor air system (DOAS) air conditioner units – one employing traditional thermal desiccant regeneration and the other utilizing Mojave’s novel electrochemical desiccant regeneration technology based on Redox Assisted electrodialysis. The Redox Assisted Dehumidification Air Conditioning (RAD-AC) technology is further developed and validated in this work to demonstrate an Integrated Seasonal Moisture Removal Efficiency (ISMRE) > 5.0 kg/kWh and shifting of ≥ 10% electric load in ≤ 72 hours. Furthermore, the longevity and durability of Mojave’s liquid desiccant air conditioning technology is validated in field testing of the thermally regenerated unit, with the unit demonstrating operation with >90% uptime while experiencing an efficiency degradation of < 10% during a testing campaign of over 5400 hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sumner County Field Validation: An Assessment of Thermal Energy Storage in Municipal Buildings in Mixed-Humid Climates

The overall aim of the project was to conduct a full-scale implementation of TES in an operational administrative building in Sumner County, Kansas with a special focus of phase change material (PCM) passive implementation in the ceiling envelope. PCM was used with the intention of increasing the ability of public buildings to shift the peak HVAC energy demand and consumption. The study was conducted during the span of three years in 3 phases, (i) phase I: energy audit (pre-retrofit) (ii) phase II: ceiling tile installation (PCM retrofit), and (iii) phase III: energy evaluation (post-retrofit). Temperature and HVAC energy measurements as well as weather data collected is used for an extensive validation study and further parametric assessment to find (a) annual HVAC energy savings (b) peak period electricity and load savings focusing on cooling dominant months of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Total System Performance Ratio—A Systems Based Approach for Evaluating HVAC System Efficiency

The prescriptive path is the most widely used approach for commercial code compliance in the United States. Though easy to implement, prescriptive approaches do not typically discriminate between minimally compliant, high-performing and poorly performing HVAC system configurations. Hence, to meet aggressive energy and carbon reduction goals, it is clear that energy codes will need to transition from prescriptive to performance-based approaches, a transition that is riddled with several challenges. This paper discusses a new HVAC system-based performance approach (HVAC System Performance) which provides a simpler solution to HVAV system evaluation compared to whole building performance, while keeping tradeoffs limited to specific building systems. The Total System Performance Ratio (TSPR) is a metric for evaluation of overall system efficiency instead of individual component efficiency, a solution which could also eventually facilitate the transition to a 100% performance-based code structure. TSPR is a ratio that compares the annual heating and cooling load of a building to the annual energy consumed by the building’s HVAC system. A calculation software tool has been developed for determining a building’s TSPR. Already incorporated into the 2018 Washington State Energy Code, this approach is also being evaluated by ASHRAE Standard 90.l Project Committee and has the potential to provide a comprehensive performance-based approach for HVAC system evaluation and analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advances in the Co-Simulation of Detailed Electrical and Whole-Building Energy Performance

This article describes recent co-simulation advances for the simultaneous modeling of detailed building electrical distribution systems and whole-building energy performance. The co-simulation architecture combines the EnergyPlus® engine for whole-building energy modeling with a new Modelica library for building an electrical distribution system model that is based on harmonic power flow. This new library allows for a higher-fidelity modeling of electrical power flows and losses within buildings than is available with current building electrical modeling software. We demonstrate the feasibility of the architecture by modeling a simple, two-zone thermal chamber with internal power electronics converters and resistive loads, and we validate the model using experimental data. The proposed co-simulation capability significantly expands the capabilities of building electrical distribution system models in the context of whole-building energy modeling, thus enabling more complex analyses than would have been possible with individual building performance simulation tools that are used to date.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using probabilistic solar power forecasts to inform flexible ramp product procurement for the California ISO

How can independent system operators (ISOs) take advantage of probabilistic solar forecasts to lower generation costs and improve reliability of power systems? We discuss one three-step approach for doing so, focusing on how such forecasts might help the California Independent System Operator (CAISO) prepare unexpected net load ramps, where net load equals gross demand minus wind and solar production. First, we enhance an existing solar forecasting system to provide well-calibrated hours-ahead probabilistic forecasts. We then relate the degree of uncertainty reflected in the forecasted prediction intervals (independent variables) to error distributions for net load ramp forecasts for the CAISO real-time market (dependent variable) using machine learning and quantile regression. Projected ramp forecast errors conditioned on solar uncertainty are translated into flexible ramp requirements that therefore reflect real-time meteorological and solar conditions, improving on typical ISO procedures. Detailed descriptions are provided on the quantile regression and kth-nearest neighbor categorization methods for accomplishing that translation. Finally, a multiple time-scale look-ahead market simulation model is applied to a 118-bus IEEE Reliability Test System, modified to represent the CAISO generation mix and demand distributions. The model runs quantify how solar-conditioned ramp requirements can, first, decrease operating costs by reducing requirements compared to often conservative unconditional methods and, second, decrease generation scarcity events and consequently improve reliability by increasing flexibility requirements at times when unconditional forecast-based requirements understate actual ramp uncertainty. Solar-conditioned ramp requirements are found to reduce generation operating costs by about 2% for the test system (which would be equivalent to over $\$100$ million per year for a CAISO-size system).

14 SOLAR ENERGY↗

Residential Natural Gas Demand Response Potential during Extreme Cold Events in Electricity-Gas Coupled Energy Systems

In regions where natural gas is used for both power generation and heating buildings, extreme cold weather events can place the electrical system under enormous stress and challenge the ability to meet residential heating and electric demands. Residential demand response has long been used in the power sector to curtail summer electric load, but these types of programs in general have not seen adoption in the natural gas sector during winter months. Natural gas demand response (NG-DR) has garnered interest given recent extreme cold weather events in the United States; however, the magnitude of savings and potential impacts—to occupants and energy markets—are not well understood. We present a case-study analysis of the technical potential for residential natural gas demand response in the northeast United States that utilizes diverse whole-building energy simulations and high-performance computing. Our results show that NG-DR applied to residential heating systems during extreme cold-weather conditions could reduce natural gas demand by 1–29% based on conservative and aggressive strategies, respectively. This indicates a potential to improve the resilience of gas and electric systems during stressful events, which we examine by estimating the impact on energy costs and electricity generation from natural gas. We also explore relationships between hourly indoor temperatures, demand response, and building envelope efficiency.

03 NATURAL GAS↗

White Paper: Research & Development for the Time at Temperature Approach

Recent advancements in nuclear power research are greatly improving reactor safety and performance through the development of Accident Tolerant Fuel (ATF) and Low-Enriched Uranium Plus (LEU+). These innovations can address Departure from Nucleate Boiling (DNB) margins, which are vital for reactor safety. DNB happens when the coolant switches to film boiling, significantly decreasing heat transfer and posing a risk of fuel cladding failure. The U.S. Nuclear Regulatory Commission (NRC) employs conservative DNB criteria, which can potentially restrict the operational flexibility and efficiency of reactors. The Time at Temperature (TaT) approach could provide a more detailed and adaptable operational guideline by establishing acceptable time-temperature limits, accounting for the duration a material can withstand elevated temperatures without losing its integrity. This method allows reactors to operate more efficiently and safely, offering additional operational margins, faster power adjustments, and improved fuel cycle economics. TaT criteria allow for higher power levels and more flexible responses to operational transients, particularly applicable for anticipated operational occurrences (AOOs) that result in short durations of post-DNB conditions. It enhances plant operational flexibility, allows faster startup times, and enables quicker power level adjustments, optimizing fuel loading patterns and improving fuel cycle economics. Implementing TaT limits reduces core design constraints, lowers fuel usage, and reduces costs, essential for the long-term sustainability of Light Water Reactors (LWRs). TaT maximizes the use of advanced fuel technologies like ATF and LEU+, further enhancing their economic and environmental benefits. To apply the TaT approach in existing LWRs, collaborative research activities among various DOE-sponsored programs are essential. These efforts should incorporate fuel experiments, physics-based high-fidelity modeling, ML-based surrogate modeling, and optimization techniques. This whitepaper proposes four research and development areas: 1) Investigation of the feasibility of new operations of LWR with updated safety limits; 2) Assessment of reactor operation limits through uncertainty reduction; 3) Evaluation of power uprate in virtual environment; and 4) Lattice and reactor core design for power uprate. Each area includes why this research is in need and a suggested scope of work. These comprehensive research areas ensure practical and beneficial advancements for existing reactors, translating innovations in nuclear fuel and cladding technology into improved reactor performance and safety.

42 - ENGINEERING↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An assessment of power flexibility from commercial building cooling systems in the United States

Understanding varying characteristics and aggregate potential of power flexibility from different building types considering regional diversity is critically important to actively engaging building resources in future eco-friendly, low-cost, and sustainable power systems. This paper presents a comprehensive characteristics analysis and potential assessment of the power flexibility from heating, ventilation, and air conditioning (HVAC) loads in commercial buildings in the U.S. using a simulation-based method. In this method, commercial buildings are first grouped by building types and climate regions. The U.S. Department of Energy Commercial Prototype Building Models are used to represent an average building in each group and are simulated to characterize corresponding power flexibility. Based on building survey data, the number of commercial buildings in each group is estimated and used to calculate aggregate power flexibility. It is found that HVAC loads in commercial buildings offer more flexibility for increasing power consumption than for decreasing it. The power consumption of commercial buildings in the U.S. can be increased by 46 GW and decreased by 40 GW on peak summer days. Among all commercial building types, standalone retail buildings provide the most absolute flexibility while the medium office buildings have the most flexibility as a percentage of the rated power consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Conceptual Framework to Describe Energy Efficiency and Demand Response Interactions

Energy efficiency (EE) and demand response (DR) resources provide important utility system and ratepayer benefits. At the same time, the rapid change in the amount and type of variable renewable energy, like solar and wind, is reshaping the role and economic value of EE and DR, and will likely affect time-dependent valuation of EE and DR measures. Utilities are increasingly interested in integrating EE and DR measures and technologies (as well as other distributed energy resources) as a strategic approach to improve their collective cost-effectiveness and performance. However, the specific EE and DR features that may be best integrated, the interplay between changing EE and DR resource potential, and the resulting utility system impacts, are not well understood. We develop a framework to identify the EE and DR attributes, system conditions, and technological factors that are likely to drive interactions between EE and DR. We apply the framework to example measures with different technology specifics (e.g., presence of controls, building type, and targeted end use) in the context of different system conditions (e.g., peak demand, load-building periods during high renewable generation output). Ultimately, the framework defines EE and DR interactions not only by the change in discretionary load (i.e., DR potential) but also by the change in likelihood of participation in EE and DR programs—as well as the change in system need for, and the overall availability of, EE and DR resources. The framework is intended to improve the integration of EE and DR in utility operational and planning activities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing Hydronic Heating for Comfort and Performance in Multifamily Housing

Inefficient control settings in multifamily boilers often lead to substantial energy and cost penalties. To address this, a Fault Detection and Diagnostic (FDD) tool was developed to automate data analysis and identify operational faults such as suboptimal outdoor temperature sensor placement, misconfigured outdoor air reset (OAR) curves, excess boiler cycling, and domestic hot water (DHW) setpoint errors. By comparing pre- and post-implementation periods and applying engineering models, the tool quantifies energy savings and reduces manual analysis time by over 90%. Testing on over 100 monitored sites and a targeted subset of 12 buildings showed an average 11% energy savings from remote optimization; further validation across 19 OAR curve changes confirmed the tool’s accuracy, predicting actual savings within ±5% for most cases. Simple payback can be under three years for many multifamily buildings, though rising hardware, labor, and fuel costs create uncertainties, and decarbonization goals increasingly shift focus to electrification. The FDD tool remains invaluable for optimizing existing boilers, enhancing future electrification measures, and adapting to new technologies by refining building load estimates. In doing so, it supports both near-term efficiency and long-term transitions to low-carbon alternatives, ensuring buildings achieve substantial cost and energy benefits throughout their system lifecycles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploring the Potential of ASHRAE Guideline 36 in District Cooling Systems: Preprint

ASHRAE Guideline 36-2021 (G36) provides high-performance control sequences for all-air and hydronic HVAC systems, and it has proven effective at reducing energy use for single building all-air equipment. The most recent version of G36 included control sequences for water-cooled chiller plants, which can be used in district cooling systems (DCSs). Despite not being a traditional application of G36 controls, DCSs could benefit from energy savings that G36 control sequences have demonstrated in single building systems. We therefore investigate the possibility to extend G36 chiller plant control from a single building to district cooling using a real-world district cooling system in Boulder, Colorado as a case study. Four timeframes representing low to peak loads are simulated and analyzed to compare energy use of the district cooling system for three control sequences. Results show that although G36 chiller plant sequences can be applied to DCSs, further analysis and potentially control optimization is needed to ensure energy savings compared to default controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Synchronization as an Indicator of Controllability in a Fleet of Water Heaters

Peak reduction is an important concern that can help reduce the growing stress on distribution grid and allow to defer investments in new capacity. However, the growing concern for customer privacy and comfort may impact the performance of load control for residential devices. Water heaters represent a convenient way of reducing peak due to their ability to store thermal energy for future use. In this paper, we developed a methodology to help utilities gain more insight with respect to the impact of load control efforts for shaving peak with no necessary information about the water heaters except the device status (on/off). To this end, we use a fleet of water heaters in a controlled residential neighborhood in Atlanta, GA. Our findings show that convergence in device status can serve as a proxy for peak shifting during hours of the evening peak.

demand response↗

Development of High-Fidelity and Efficient Modeling Capabilities for Enabling Co-Optimization of Fuels and Multi-Mode Engines

The objective of this closely coordinated research project is to develop improved physical sub-models and innovative numerical algorithms to enable accurate and efficient predictions of multi-mode combustion to support EERE’s Co-Optima program. To this end, a research pro-gram is proposed that seeks • to develop accurate submodels for predicting multi-mode combustion regimes, wall-heat transfer, non-equilibrium plasma ignition, and combustion-mode transition, • to develop dynamic load-rebalancing algorithms and efficient semi-implicit time-integration schemes for enabling exascale computing, • to validate the computational submodels against experiments and direct numerical simulation (DNS) data in conjunction with sensitivity analysis, and • to support the direct transition of the resulting sub-models into other engine-simulation tools through the development of self-contained modules. All sub-models will be integrated into the open-source exascale engine-simulation platform Nek5000.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗