Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Diagnostic accuracy of F-18 FDG PET/CT for characterization of colorectal focal FDG uptake: a systematic review and meta-analysis

Introduction: We aimed to explore the role of the diagnostic accuracy of F-18 fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) for characterization of incidental colorectal focal FDG uptake through a systematic review and meta-analysis. Methods: The MEDLINE, EMBASE, and Cochrane Library database, from the earliest available date of indexing through April 30, 2018, were searched for studies evaluating the diagnostic performance of F-18 FDG PET/CT for characterization of incidental colorectal focal FDG uptake. We determined the sensitivities and specificities across studies, calculated positive and negative likelihood ratios (LR+ and LR−), and constructed summary receiver operating characteristic curves. Results: Across 8 studies (1451 patients), the pooled sensitivity for F-18 FDG PET/CT was 0.87 (95% CI 0.82–0.90) without heterogeneity (χ{sup 2} = 10.84, p = 0.37) and a pooled specificity of 0.83 (95% CI 0.76–0.89) with heterogeneity (χ{sup 2} = 130.1, p = 0.00). Likelihood ratio (LR) syntheses gave an overall positive likelihood ratio (LR+) of 5.2 (95% CI 3.6–7.4) and negative likelihood ratio (LR−) of 0.16 (95% CI 0.12–0.22). The pooled DOR was 32 (95% CI 20–51). Conclusion: F-18 FDG PET/CT demonstrated good sensitivity and specificity for characterization of incidental colorectal focal FDG uptake. At present, the literature regarding the use of F-18 FDG PET/CT for characterization of incidental colorectal focal FDG uptake remains still limited; thus, further large multicenter studies would be necessary to substantiate the diagnostic accuracy of F-18 FDG PET/CT for characterization of incidental colorectal focal FDG uptake.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analyzing the post-contrast attenuation of the esophageal wall on routine contrast-enhanced MDCT examination can improve the diagnostic accuracy in response evaluation of the squamous cell esophageal carcinoma to neoadjuvant chemoradiotherapy in comparison with the esophageal wall thickness

Purpose: To evaluate the accuracy of the multidetector computed tomography (MDCT) in the response evaluation of the esophageal squamous cell carcinoma (ESCC) to neoadjuvant chemoradiotherapy (nCRT) by analyzing the thickness and post-contrast attenuation of the esophageal wall after the nCRT. Methods: Contrast-enhanced (CE)-MDCT examinations in portal venous phase of one hundred patients with locally advanced ESCC who received nCRT and underwent esophageal resection and histopathology assessment of tumor regression grade (TRG) were retrospectively analyzed by measuring the maximal thickness and mean density of the esophageal wall in the segment involved by tumor and visually searching for hyperdense foci within it. Diagnostic performance was evaluated using the ROC analysis. Results: Average attenuation of the esophageal wall had stronger diagnostic performance for predicting pathologic complete regression (pCR) (AUC = 0.994; p < 0.001) in relation to maximal esophageal wall thickness (AUC = 0.731; p < 0.001). Maximal esophageal wall thickness ≤ 9 mm and average attenuation of the esophageal wall ≤ 64 HU predicted pCR with the sensitivity, specificity, and overall accuracy of 62.5%, 77.9%, and 73%, and 96.9%, 98.5%, and 98%, respectively. Combination of both cutoff values enabled correct assessment of pCR with the 100% accuracy. Visual detection of the hyperdense focus within the esophageal wall predicted pCR with the sensitivity, specificity, and overall accuracy values of 100%, 94.1%, and 96%, respectively. Conclusion: Visual analysis and measurement of post-contrast attenuation of the esophageal wall after the nCRT can improve diagnostic accuracy of MDCT in the response evaluation of the ESCC to nCRT in comparison with measuring the esophageal wall thickness.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 68}Ga-PSMA-11 PET/CT in newly diagnosed prostate cancer: diagnostic sensitivity and interobserver agreement

Purpose: To determine the diagnostic sensitivity and interobserver agreement of Gallium 68-prostate-specific membrane antigen positron emission tomography/computed tomography ({sup 68}Ga-PSMA-11 PET/CT) imaging for diagnosis and staging of patients with newly diagnosed prostate cancer (PC). Materials and methods: One hundred and seventy-three men (mean age, 68 ± 7.7 years; range 46–84 years) with newly diagnosed, untreated PC were enrolled in this prospective study between January 2017 and August 2018. All patients underwent a {sup 68}Ga-PSMA-11 PET/CT examination. For each patient, we determined the disease stage, the Gleason score, and the maximum standardized uptake value (SUVmax) for primary prostatic tumor and extraprostatic metastases. The diagnostic sensitivity and interobserver agreement of {sup 68}Ga-PSMA-11 PET/CT for diagnosis and staging of PC were established by histopathology as the reference standard. Results: {sup 68}Ga-PSMA-11 PET/CT examinations were interpreted as positive for PC in 166 of 173 patients (101 patients had primary prostatic tumor only, two patients had extraprostatic metastases only and 63 patients had combined lesions). The sensitivity of {sup 68}Ga-PSMA-11 PET/CT examination in the diagnosis of PC was 96%. {sup 68}Ga-PSMA-11 PET/CT produced a significant change of stage in 28.6% patients with an upstage in 17.9% patients and a downstage in 10.7% patients. The interobserver agreements were almost good to perfect (k = 0.63–0.89) for visual image interpretation, SUVmax measurement, and tumor staging. Conclusion: {sup 68}Ga-PSMA-11 PET/CT is a valuable tool with high diagnostic sensitivity (96%) and high reproducibility for diagnosis and staging of patients with newly diagnosed PC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic imaging of hepatocellular carcinoma at community hospitals and their tertiary referral center in the era of LI-RADS: a quality assessment study

Purpose: To assess guideline compliance and quality of hepatocellular carcinoma, (HCC) diagnostic imaging within community hospitals (CH) and their Tertiary referral center (TRC) in a moderately high incidence region. Methods: Initial diagnostic workup CT/MRI scans of 251 patients (122 CH, 112 TRC, 17 Non-TRC academic) with HCC over a 15-month period were assessed for Liver reporting and Data System (LI-RADS) guideline compliance. 269 scans (182 CT, 87 MRI) were qualitatively evaluated by 2 independent blinded radiologists for arterial timing, overall image quality, noise and sharpness, with quantification of interobserver variability. The contrast enhancement ratio (CER) for the largest HCC on each scan was calculated using pre- and post-contrast images. Results: 103/104 (99%) of TRC and 44/78 (56%) of CH CTs adhered to LI–RADS imaging guidelines (P < 0.0001). Lack of delayed phase accounted for 32/34 (94%) of noncompliant CH CTs. Regarding MRI, 19/19 (100%) of TRC and 60/68 (88%) of CH scans were adherent (P = 0.12). For both modalities, overall image quality, noise and sharpness were rated significantly higher for TRC than CH. There was moderate interobserver agreement with intraclass correlation coefficient of 0.73, 0.70 and 0.63, respectively. Arterial-phase timing was rated adequate for CT in 75/104 TRC (72%) and 10/68 (14%) CH scans (P < 0.0001) and for MRI in 8/19 (42%) TRC and 23/68 (33%) CH scans (P = 0.17). The CER was significantly higher for TRC versus CH (2.9 vs. 1.9, P < 0.001) and MRI (0.9 vs. 0.7, P = 0.03). Conclusions: Community hospital HCC diagnostic scans significantly lag in critical quality parameters of tumor enhancement, arterial phase timing, perceived image quality, and LI-RADS CT technique compliance compared to a TRC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An assessment of the safety, hemodynamic response, and diagnostic accuracy of commonly used vasodilator stressors in patients with severe aortic stenosis

Background: Increasing numbers of patients are undergoing transcatheter aortic valve replacement, which often involves assessment of coronary artery disease ischemic burden. The safety and diagnostic accuracy of vasodilator stress agents in patients with severe aortic stenosis (AS) undergoing SPECT myocardial perfusion imaging (MPI) has not been established. Methods: Patients with severe AS (valve area <1 cm{sup 2}) on echocardiography who underwent vasodilator stress SPECT MPI at two centers were identified. Patients with aortic valve intervention prior to MPI or who underwent concurrent exercise during stress testing were excluded. AS patients were matched to controls without AS based on age, gender, BMI, ejection fraction, and stress agent. Symptoms, serious adverse events, hemodynamic response, and correlation to invasive angiography were assessed. Results: A total of 95 cases were identified with 45% undergoing regadenoson, 31% dipyridamole, and 24% adenosine stress. A significant change in systolic blood pressure (BP), cases vs controls, was observed with adenosine [−17.9 ± 20.1 vs −2.6 ± 24.9 P = .03)], with a trend toward significance with regadenoson [−16.8 ± 20.3 vs −9.4 ± 17.9 (P = .08)] and dipyridamole [−17.8 ± 20.6 vs -9.0 ± 12.1 (P = .05)]. The change in heart rate was significantly different only for adenosine [5.3 ± 16.8 vs 14.2 ± 10.8 (P = .04)]. Overall, 45% of cases vs 24% of controls (P = .004) had a >20 mmHg decrease in systolic BP. Age, BMI, and resting systolic BP were related to a >20 mmHg decrease in systolic BP on univariate analysis, although only higher resting systolic BP was a predictor on multivariate analysis. In 33 patients who underwent angiography, the sensitivity, specificity, and diagnostic accuracy of vasodilator stress MPI was 77%, 69%, and 73%, respectively. No serious adverse events occurred in the severe AS patients. Conclusion: Severe AS patients are more likely to have a hemodynamically significant decrease in systolic BP with vasodilator stress. There were no serious adverse events in this severe AS cohort with good diagnostic performance of MPI compared to angiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved diagnostic accuracy of thallium-201 myocardial perfusion single-photon emission computed tomography with CT attenuation correction

Background: The benefits of attenuation correction (AC) in technetium-99m myocardial perfusion imaging (MPI) have been well established. However, the value of thallium (Tl-201) AC and routine computed tomography AC (CTAC) were less well established. The aims of this study were to evaluate the diagnostic performance of thallium (Tl-201) MPI with additional CTAC and to determine which participants would benefit most. Methods and Results: A total of 108 consecutive patients who underwent Tl-201 MPI and received coronary angiography within 3 months were enrolled. Diagnostic performance was determined by sensitivity, specificity, and receiver operating characteristic curve analysis. Subgroup analyses were performed using gender and obesity. CTAC improved the area under the curve (0.84 vs. 0.77, P = 0.037 at patient level), primarily due to a significant improvement in specificity (0.78 vs. 0.57, P = 0.013) and no significant difference in sensitivity (0.79 vs. 0.82, P = 0.75). In subgroup analysis, CTAC was most helpful in obese subjects, men, and especially right coronary artery lesions. Conclusions: CTAC significantly improved diagnostic performance primarily by increasing the specificity, and the improvements were significantly greater in obese patients and male patients. These findings suggest that CTAC should be applied to Tl-201 MPI as routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cerebrospinal fluid CD4+ T lymphocyte-derived miRNA-let-7b can enhances the diagnostic performance of Alzheimer's disease biomarkers

Highlights: • Let-7b in CSF is mainly derived from CD4+ T lymphocytes. • Let-7b is associated with the AD biomarkers. • Let-7b can improve the diagnostic performance of AD biomarkers. Alzheimer's disease is very difficult to clinically diagnose. miRNAs constitute the promising next generation of Alzheimer's disease (AD) biomarkers and have the potential to diagnose neurodegenerative diseases. In this study, 94 subjects underwent extensive dementia screening. Let-7b miRNA was found to increase in association with the progression of AD, and the increase in let-7b miRNA was mainly due to CD4+ T cells in the cerebrospinal fluid (CSF). Additionally, let-7b was positively correlated with the expression of t-Tau and p-Tau. The inclusion of let-7b in Aβ40-Aβ42 or t-tau–p-tau logistic regression and receiver operating characteristic predictive models can significantly improve the diagnostic performance. Overall, let-7b has an important association with the pathology of AD and can be used as an adjunct to improve the diagnostic performance of traditional AD biomarkers.

60 APPLIED LIFE SCIENCES↗

Two-color pyrometry based flame to fuel surface radiative heat flux diagnostic using flamelets

In this study, a non-intrusive two-color pyrometry based radiative heat flux diagnostic is presented that accounts for the self-absorption effects. This diagnostic relies on looking up the flame temperature and soot volume fraction using the ratio of color intensities obtained from digital cameras and numerical solutions of 1D steady-state diffusion flames. Virtual two color pyrometry of computed flame show a unique one-to-one mapping of strained flames with intensity ratio; thereby allowing flames to be indexed and creation of a two-color flamelet manifold (TCFM). The TCFM is a function of two variables; the ratio of red to green intensities (flame index) and physical distance to the stoichiometric surface defined using a level-set function. The developed diagnostic is used in upward flame spread experiments where an approximate flame hull reconstruction method is applied to provide the 3D level-set function and intensity ratio for use of TCFM to provide radiative absorption properties for 3D ray tracing. Accounting for self- absorption effects provide improved soot volume fraction estimates. In conclusion, the radiative heat flux estimates are found to be in very good agreement with literature and improved results are obtained near the flame base.

42 ENGINEERING↗

Computational diagnostics for flame acceleration and transition to detonation in a hydrogen/air mixture

A new computational diagnostic method for pressure-induced compressibility is proposed by projecting its local contribution to the chemical explosive mode (CEM) in the chemical explosive mode analysis (CEMA) framework. The new method is validated for the study of detonation development during the deflagration-to-detonation transition (DDT) process. The flame characteristics are identified through the quantification of individual CEM contributions of chemical reaction, diffusion, and pressure-induced compressibility. Numerical simulations are performed to investigate the DDT processes in a stoichiometric hydrogen-air mixture. A Godunov algorithm, fifth-order in space, and third-order in time are used to solve the fully compressible Navier-Stokes equations on a dynamically adapting mesh. A single-step, calibrated chemical diffusive model (CDM) described by Arrhenius kinetics is used for energy release and conservation between the fuel and the product. The new diagnostic method is first applied to onedimensional (1D) canonical flame configurations followed by two-dimensional (2D) simulations of DDT in an obstructed channel where different detonation initiation scenarios are examined using the new CEMA projection formulation. Detailed examinations of the idealized configuration of detonation initiation through shock focusing mechanism at a flame front are also studied using the new formulation. A comparison of the currently proposed CEMA projection and the original formulation by the authors suggests that including the pressure-induced compressibility is essential for the use of CEMA in DDT process. The results also show that the new formulation of CEMA projection can successively capture the detonation initiation through either a gradient mechanism or a direct initiation mechanism, and therefore can be used as an effective local analytical tool for the computational diagnostics of detonation initiation in a DDT process. It was found that detonation development is characterized by a strong contribution of chemistry role to the CEM which is pivotal to the initiation of detonation. The role of compressibility is found enhanced at the edge of the detonation front where diffusion was found to have minimal effects on detonation development.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Developing a diagnostic for energetic laser-Compton produced photon beams

This paper describes the design and simulation of a radiation detector system for diagnostic measurements of photon beams produced by Thomson or Compton Scattering. The photon beam is Compton scattered in a thin passive converter, and the resulting electrons are analyzed using a charge-coupled device-based tracker and classification algorithms. The flux of the scattered electrons is much lower than that of the photon beam and is additionally dispersed. This dispersal enables measurements while avoiding pileup, which is important in order to provide diagnostic information from intense 'shot’ based pulsed systems, such as those being built to leverage laser wakefield accelerators. Simulations indicate that the designed system is capable of resolving beam parameters from a single shot. The fidelity to which various beam parameters can be resolved is presented as are methods that could result in further improvement to diagnostic resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptive model tuning studies for non-invasive diagnostics and feedback control of plasma wakefield acceleration at FACET-II

Beam-driven plasma wakefield acceleration (PWFA) achieves the same energy gain in a single meter, for which conventional accelerators require several kilometers, however much work is still required to match the beam quality of conventional accelerators. The PWFA processes to be studied at the FACET-II facility will utilize extremely short (down to a few fs) high energy (10 GeV), high charge (few nC) electron and eventually positron bunches. The PWFA process is extremely sensitive to the detailed longitudinal current profiles of these bunches and it would be of great benefit to have precise measurement and control of these profiles. We present an adaptive model tuning technique for FACET-II to adaptively tune online models based on real time accelerator and beam data to continuously provide a non-invasive diagnostic which predicts the longitudinal phase space (LPS) of extremely short and highly compressed electron beams, which otherwise require destructive X-band transverse deflecting cavity (XTCAV)-based measurements. Based on simulation studies, our method has the potential for: (1). The development of a non-invasive longitudinal phase space diagnostic by adaptively tuning models based on non-invasive measurements such as energy spread spectra which could be recorded at all of the bunch compressors in the facility. (2). Utilize these diagnostic to perform model-independent feedback-based to achieve desired longitudinal phase space distributions. (3). Utilize the model-independent feedback approach to maximize energy gain while minimizing emittance growth and energy gain variance of the PWFA process by tuning accelerator parameters, while monitoring what longitudinal phase space the algorithm has found, information that will be useful for further analytical and simulation studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray Emission Spectroscopy as an in Situ Diagnostic Tool for X-ray Crystallography of Metalloproteins Using an X-ray Free-Electron Laser

Serial femtosecond crystallography (SFX) using the ultrashort X-ray pulses from a X-ray free-electron laser (XFEL) provides a new way of collecting structural data at room temperature that allows for following the reaction in real time after initiation. XFEL experiments are conducted in a shot-by-shot mode as the sample is destroyed and replenished after each X-ray pulse, and therefore, monitoring and controlling the data quality by using in situ diagnostic tools is critical. To study metalloenzymes, we developed the use of simultaneous collection of X-ray diffraction of crystals along with X-ray emission spectroscopy (XES) data that is used as a diagnostic tool for crystallography, by monitoring the chemical state of the metal catalytic center. We have optimized data analysis methods and sample delivery techniques for fast and active feedback to ensure the quality of each batch of samples and the turnover of the catalytic reaction caused by reaction triggering methods. Here, we describe this active in situ feedback system using Photosystem II as an example that catalyzes the oxidation of H2O to O2at the Mn4CaO5active site. We used the first moments of the Mn Kβ1,3emission spectra, which are sensitive to the oxidation state of Mn, as the primary diagnostics. This approach is applicable to different metalloproteins to determine the integrity of samples and follow changes in the chemical states of the reaction that can be initiated by light or activated by substrates and offers a metric for determining the diffraction images that are used for the final data sets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advancing Diagnostic Model Evaluation to Better Understand Water Shortage Mechanisms in Institutionally Complex River Basins

Abstract Water resources systems models enable valuable inferences on consequential system stressors by representing both the geophysical processes determining the movement of water and the human elements distributing it to its various competing uses. This study contributes a diagnostic evaluation framework that pairs exploratory modeling with global sensitivity analysis to enhance our ability to make inferences on water scarcity vulnerabilities in institutionally complex river basins. Diagnostic evaluation of models representing institutionally complex river basins with many stakeholders poses significant challenges. First, it needs to exploit a large and diverse suite of simulations to capture important human‐natural system interactions as well as institutionally aware behavioral mechanisms. Second, it needs to have performance metrics that are consequential and draw on decision‐relevant model outputs that adequately capture the multisector concerns that emerge from diverse basin stakeholders. We demonstrate the proposed model diagnostic framework by evaluating how potential interactions between changing hydrologic conditions and human demands influence the frequencies and durations of water shortages of varying magnitudes experienced by hundreds of users in a subbasin of the Colorado River. We show that the dominant factors shaping these effects vary both across users and, for an individual user, across percentiles of shortage magnitude. These differences hold even for users sharing diversion locations, demand levels or water right seniority. Our findings underline the importance of detailed institutional representation for such basins, as institutions strongly shape how dominant factors of stakeholder vulnerabilities propagate through the complex network of users.

Hadjimichael, Antonia↗

Systematic benchmarking demonstrates large language models have not reached the diagnostic accuracy of traditional rare-disease decision support tools

Large language models (LLMs) show promise in supporting differential diagnosis, but their performance is challenging to evaluate due to the unstructured nature of their responses, and their accuracy compared to existing diagnostic tools is not well characterized. To assess the current capabilities of LLMs to diagnose genetic diseases, we benchmarked these models on 5213 previously published case reports using the Phenopacket Schema, the Human Phenotype Ontology and Mondo disease ontology. Prompts generated from each phenopacket were sent to seven LLMs, including four generalist models and three LLMs specialized for medical applications. The same phenopackets were used as input to a widely used diagnostic tool, Exomiser, in phenotype-only mode. The best LLM ranked the correct diagnosis first in 23.6% of cases, whereas Exomiser did so in 35.5% of cases. While the performance of LLMs for supporting differential diagnosis has been improving, it has not reached the level of commonly used traditional bioinformatics tools. Future research is needed to determine the best approach to incorporate LLMs into diagnostic pipelines.

Reese, Justin T. [Lawrence Berkeley National Labor↗

In-situ monitoring for liquid metal jetting using a millimeter-wave impedance diagnostic

Abstract This article presents a millimeter-wave diagnostic for the in-situ monitoring of liquid metal jetting additive manufacturing systems. The diagnostic leverages a T-junction waveguide device to monitor impedance changes due to jetted metal droplets in real time. An analytical formulation for the time-domain T-junction operation is presented and supported with a quasi-static full-wave electromagnetic simulation model. The approach is evaluated experimentally with metallic spheres of known diameters ranging from 0.79 to 3.18 mm. It is then demonstrated in a custom drop-on-demand liquid metal jetting system where effective droplet diameters ranging from 0.8 to 1.6 mm are detected. Experimental results demonstrate that this approach can provide information about droplet size, timing, and motion by monitoring a single parameter, the reflection coefficient amplitude at the input port. These results show the promise of the impedance diagnostic as a reliable in-situ characterization method for metal droplets in an advanced manufacturing system.

42 ENGINEERING↗

Deployment and validation of predictive 6-dimensional beam diagnostics through generative reconstruction with standard accelerator elements

Understanding the 6-dimensional phase space distribution of particle beams is essential for optimizing accelerator performance. Conventional diagnostics such as use of transverse deflecting cavities offer detailed characterization but require dedicated hardware and space. Generative phase space reconstruction (GPSR) methods have shown promise in beam diagnostics, yet prior implementations still rely on such components. Here we present the first experimental implementation and validation of the GPSR methodology, realized by the use of standard accelerator elements including accelerating cavities and dipole magnets, to achieve complete 6-dimensional phase space reconstruction. Through simulations and experiments at the Pohang Accelerator Laboratory X-ray Free Electron Laser facility, we successfully reconstruct complex, nonlinear beam structures. Furthermore, we validate the methodology by predicting independent downstream measurements excluded from training, revealing the reconstruction closely resembling ground truth. This advancement establishes a pathway for predictive diagnostics across beamline segments while reducing hardware requirements and expanding applicability to various accelerator facilities.

Kim, Seongyeol [Pohang Univ. of Science and Techno↗

Beyond traditional diagnostics: Identifying active galactic nuclei using spectral energy distribution fitting in DESI data

Active galactic nuclei (AGN) are typically identified through their distinctive X-ray or radio emissions, mid-infrared (MIR) colors, or emission lines. However, each method captures different subsets of AGN due to signal-to-noise (S/N) limitations, redshift coverage, and extinction effects, underscoring the necessity for a multiwavelength approach for comprehensive AGN samples. This study explores the effectiveness of spectral energy distribution (SED) fitting as a robust method for AGN identification. Using CIGALE optical-MIR SED fits on DESI Early Data Release galaxies, we compare SED-based AGN selection (AGNFRAC ≥ 0.1) with traditional methods including BPT diagrams, WISE colors, X-ray, and radio diagnostics. The SED fitting identifies ∼70% of narrow- and broad-line AGN and 87% of WISE-selected AGN. Incorporating high S/N WISE photometry reduces star-forming galaxy contamination from 62% to 15%. Initially, ∼50% of SED-AGN candidates are undetected by standard methods, but additional diagnostics classify ∼85% of these sources, revealing low-ionization nuclear emission-line regions and retired galaxies potentially representing evolved systems with weak AGN activity. Further spectroscopic and multiwavelength analysis will be essential to determine the true AGN nature of these sources. SED fitting provides complementary AGN identification, unifying multiwavelength AGN selections. This approach enables more complete – albeit somewhat contaminated – AGN samples, which are essential for upcoming large-scale surveys where spectroscopic diagnostics may be limited.

Seyfert↗

Correlation ECE diagnostic in Alcator C-Mod

Correlation ECE (CECE) is a diagnostic technique that allows measurement of small amplitude electron temperature, Te, fluctuations through standard cross-correlation analysis methods. In Alcator C-Mod, a new CECE diagnostic has been installed[Sung RSI 2012], and interesting phenomena have been observed in various plasma conditions. We find that local Te fluctuations near the edge (ρ ~ 0:8) decrease across the linearto- saturated ohmic confinement transition, with fluctuations decreasing with increasing plasma density[Sung NF 2013], which occurs simultaneously with rotation reversals[Rice NF 2011]. Te fluctuations are also reduced across core rotation reversals with an increase of plasma density in RF heated L-mode plasmas, which implies that the same physics related to the reduction of Te fluctuations may be applied to both ohmic and RF heated L-mode plasmas. In I-mode plasmas, we observe the reduction of core Te fluctuations, which indicates changes of turbulence occur not only in the pedestal region but also in the core across the L/I transition[White NF 2014]. The present CECE diagnostic system in C-Mod and these experimental results are described in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗