Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed control system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Quantifying the Impact of Unavailability in Cyber-Physical Environments

The Supervisory Control and Data Acquisition (SCADA) system discussed in this work manages a distributed control network for the Tunisian Electric & Gas Utility. The network is dispersed over a large geographic area that monitors and controls the flow of electricity/gas from both remote and centralized locations. The availability of the SCADA system in this context is critical to ensuring the uninterrupted delivery of energy, including safety, security, continuity of operations and revenue. Such SCADA systems are the backbone of national critical cyber-physical infrastructures. Herein, we propose adapting the Mean Failure Cost (MFC) metric for quantifying the cost of unavailability. This new metric combines the classic availability formulation with MFC. The resulting metric, so-called Econometric Availability (EA), offers a computational basis to evaluate a system in terms of the gain/loss ($/hour of operation) that affects each stakeholder due to unavailability.

Availability↗

Hierarchical Distribution System Adaptive Restoration with Diverse Distributed Energy Resources

Distributed energy resources (DERs) can be utilized as alternative power sources for fast service recovery in cases of distribution system outages. However, the diverse characteristics and stochastic nature of DERs impose challenges on the optimal operation of di-verse resources during the restoration phase. Here, we introduce a hierarchical structure to coordinate distribution system entities and propose an adaptive restoration strategy to sustain a reliable power supply to outage loads in an unbalanced distribution system utilizing DERs. An efficient system reconfiguration model is developed to guarantee the radiality of restoration islands. The flexibility of DERs is evaluated by a novel method that focuses on the cumulative energy consumption, the superiority of which is also proven. Model predictive control (MPC) is adopted to enable the adjustment of system topology and DER operation strategies based on up-to-date data. The performance of the proposed restoration model is validated on a modified IEEE 123-bus test system. Moreover, the effectiveness of the proposed novel flexibility assessment and the MPC-based adaptive restoration strategy are verified through comparative studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Isolation contactor state control system

A controller area network (CAN) installed on a hybrid electric vehicle provides one node with control of high voltage power distribution system isolation contactors and the capacity to energize a secondary electro-mechanical relay device. The output of the secondary relay provides a redundant and persistent backup signal to the output of the node. The secondary relay is relatively immune to CAN message traffic interruptions and, as a result, the high voltage isolation contactor(s) are less likely to transition open in the event that the intelligent output driver should fail.

33 ADVANCED PROPULSION SYSTEMS↗

Protecting Accelerator Control Systems in the Face of Sophisticated Cyber Attacks

Cyber security for industrial control systems has received significant attention in the past two years. The news coverage of the Stuxnet attack, believed to be targeted at the control system for a uranium enrichment plant, brought the issue to the attention of news media and policy makers. This has led to increased scrutiny of control systems for critical infrastructure such as power generation and distribution, and industrial systems such as chemical plants and petroleum refineries. The past two years have also seen targeted network attacks aimed at corporate and government entities including US Department of Energy National Laboratories. Both of these developments have potential repercussions for the control systems of particle accelerators. The need to balance risks from potential attacks with the operational needs of an accelerator present a unique challenge for the system architecture and access model.

02 PETROLEUM↗

Status Of The National Ignition Campaign And National Ignition Facility Integrated Computer Control System

The National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory is a stadium-sized facility that will contains a 192-beam, 1.8-Megajoule, 500-Terawatt, ultraviolet laser system together with a 10-meter diameter target chamber with room for multiple experimental diagnostics. NIF is the world's largest and most energetic laser experimental system, providing a scientific center to study inertial confinement fusion (ICF) and matter at extreme energy densities and pressures. NIF's laser beams are designed to compress fusion targets to conditions required for thermonuclear burn. NIF is operated by the Integrated Computer Control System (ICCS) in an object-oriented, CORBA-based system distributed among over 1800 frontend processors, embedded controllers and supervisory servers. In the fall of 2010, a set of experiments began with deuterium and tritium filled targets as part of the National Ignition Campaign (NIC). At present, all 192 laser beams routinely fire to target chamber center to conduct fusion and high energy density experiments. During the past year, the control system was expanded to include automation of cryogenic target system and over 20 diagnostic systems to support fusion experiments were deployed and utilized in experiments in the past year. This talk discusses the current status of the NIC and the plan for controls and information systems to support these experiments on the path to ignition.

42 ENGINEERING↗

Local Dynamic Reactive Power for Correction of System Voltage Problems

Distribution systems are experiencing outages due to a phenomenon known as local voltage collapse. Local voltage collapse is occurring in part because modern air conditioner compressor motors are much more susceptible to stalling during a voltage dip than older motors. These motors can stall in less than 3 cycles (.05s) when a fault, such as on the sub-transmission system, causes voltage to sag to 70 to 60%. The reasons for this susceptibility are discussed in the report. During the local voltage collapse, voltages are depressed for a period of perhaps one or two minutes. There is a concern that these local events are interacting together over larger areas and may present a challenge to system reliability. An effective method of preventing local voltage collapse is the use of voltage regulation from Distributed Energy Resources (DER) that can supply or absorb reactive power. DER, when properly controlled, can provide a rapid correction to voltage dips and prevent motor stall. This report discusses the phenomenon and causes of local voltage collapse as well as the control methodology we have developed to counter voltage sag. The problem is growing because of the use of low inertia, high efficiency air conditioner (A/C) compressor motors and because the use of electric A/C is growing in use and becoming a larger percentage of system load. A method for local dynamic voltage regulation is discussed which uses reactive power injection or absorption from local DER. This method is independent, rapid, and will not interfere with conventional utility system voltage control. The results of simulations of this method are provided. The method has also been tested at the ORNL s Distributed Energy Communications and Control (DECC) Laboratory using our research inverter and synchronous condenser. These systems at the DECC Lab are interconnected to an actual distribution system, the ORNL distribution system, which is fed from TVA s 161kV sub-transmission backbone. The test results are also provided and discussed. The simulations and testing show that local voltage control from DER can prevent local voltage collapse. The results also show that the control can be provided so quickly, within 0.5 seconds, that is does not interfere with conventional utility methods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cyber Resilient Design and Controls for Energy Systems

As the grid of today is evolving into a highly distributed and autonomous cyber-physical system with higher penetration of Distributed Energy Resources (DERs) and autonomous controls that are dependent on the cyber infrastructure, there are novel and increasing challenges to cyber-resilient operation of the grid. While the traditional mechanisms take a "bolt on" approach to cybersecurity and resiliency, this talk presents two novel technologies developed at NREL that "bake in" security and resilience into the design and control of the grid. An Adaptive Resilience Metrics framework is a novel mechanism for system owners and operators to understand the impact of cyber and physical system design and topology on the resilient operation, while also helping determine optimal policies in response to adverse cyber events. Along with that a zero-knowledge proof-based technique helps incorporate security into the controls layer by focusing on computational integrity rather than data integrity. By leveraging design and control properties unique to Operational Technology systems these technologies will not only help enhance cyber-resilience for the grid of today, but a highly distributed and autonomous grid of tomorrow.

cyber resilience↗

Implementation of a Publish-Subscribe Protocol in Microgrid Islanding and Resynchronization with Self-Discovery

Communications systems and protocols are becoming second nature to utilities operating distribution systems. Traditionally, centralized communication approaches are often used, while recently in microgrid applications, distributed communication and control schema emerge offering several advantages such as improved system reliability, plug-and-play operation and distributed intelligence. Still, operation and control of microgrids including distributed communication schema have been less of a discussion in the literature. To address the challenge of multiple-inverter microgrid synchronization, a publish-subscribe protocol based, Data Distribution Service (DDS), communication schema for microgrids is proposed in this paper. The communication schema is discussed in details for individual devices such as generators, photovoltaic systems, energy storage systems, microgrid point of common coupling switch, and supporting applications. In conclusion, islanding and resynchronization of a microgrid are demonstrated on a test-bed utilizing this schema.

25 ENERGY STORAGE↗

On a Future for Smart Inverters with Integrated System Functions

The modern electric power grid is gradually evolving to include high penetration power electronics in a distributed architecture which will pose pressing new challenges on power quality, system control, and operation. The state-of-the-art smart inverters for solar photovoltaics may not be sufficient to address some of the stability and control challenges such as harmonic resonances due to the interactions of multiple power electronics converters. This paper discusses a future of smart inverters with integrated system functions and its associated challenges, and identifies smart inverter research trends and features in the context of flexible control architectures. Future power electronics research will shift from hardware solutions to more control solutions with integrated system functions under distributed power grid scenarios with small-scale power electronics interfaced with distributed generations and loads.

Xue, Yaosuo↗

Event-Based Analysis of Solar Power Distribution Feeder Using Micro-PMU Measurements

Solar distribution feeders are commonly used in solar farms that are integrated into distribution substations. In this paper, we focus on a real-world solar distribution feeder and conduct an event-based analysis by using micro-PMU measurements. The solar distribution feeder of interest is a behind-the-meter solar farm with a generation capacity of over 4 MW that has about 200 low-voltage distributed photovoltaic (PV) inverters. The event-based analysis in this study seeks to address the following practical matters. First, we conduct event detection by using an unsupervised machine learning approach. For each event, we determine the event’s source region by an impedancebased analysis, coupled with a descriptive analytic method. We segregate the events that are caused by the solar farm, i.e., locallyinduced events, versus the events that are initiated in the grid, i.e., grid-induced events, which caused a response by the solar farm. Second, for the locally-induced events, we examine the impact of solar production level and other significant parameters to make statistical conclusions. Third, for the grid-induced events, we characterize the response of the solar farm; and make comparisons with the response of an auxiliary neighboring feeder to the same events. Fourth, we scrutinize multiple specific events; such as by revealing the dynamics to the control system of the solar distribution feeder. The results and discoveries in this study are informative to utilities and solar power industry.

14 SOLAR ENERGY↗

Significance of Dynamic and Transient Analysis in the Design and Operation of Hybrid Energy Systems

Energy systems were historically designed and operated with a specific energy conversion objective, while managing loads and resources. In the recent years, the increased utilization of non-dispatchable renewable sources such as wind and solar has played a role in power quality and the reliability of power systems. In order to mitigate the risk associated with the non-dispatchable resources an integrated approach, such as Hybrid Energy Systems (HES), has to be taken, integrating the loads and resource management between the traditional thermal power plants and the non-dispatchable resources. As our electric energy becomes more diverse in its generation resources, the HES with its operational control system, its real-time view and its dynamic decisions making will become an essential part of the integrated energy systems and improve the overall grid reliability. The operational constraints of the energy sources on both the thermal power plants and the non-dispatchable resources in HES, plays a vital role in the planning and design stage. It is an established fact that the choice of energy source depends on the available natural resources and possible infrastructure. A critical component of decision-making depends on the complementary nature and controllability of the energy sources to supply the load demands with high reliability. Controllability of complex HES to achieve desired performance and flexibility is implemented via coordinated control systems while simultaneously generating electricity and other useful products such as useful heat or hydrogen. These systems are based on instrumentation, signal processing, control theory, and engineering system design. The entire HES along with the control systems are characterized by widely varying time constants. Hence, for a well-coordinated control and operation, we propose physics based modeling of the subsystems to assist in a dynamic and transient analysis. Dynamic and transient analysis in real and non-real time domain of the potential sources is capable of providing satisfactory results at the feasibility analysis stage. A simplified HES consisting of complementary energy sources is used to demonstrate the proposed approach. Suitable real time simulations to perform dynamic and transient analysis will be performed to verify results from the non-real time analysis. The role of such analyses, especially the real time dynamic and transient analysis for manual controls is elaborated. It is also discussed that faster than real time simulation will pave the future for controller rooms and hence manual control procedures. Multiple tools such as Real Time Simulator, Matlab®, Simulink®, PSCAD®, MOOSE, etc. are expected to be used for the HES analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Review of Distributed Secondary Control Architectures in Islanded-Inverter-Based Microgrids

The increasing energy demand, the shortage of energy resources, and the environmental challenges faced by conventional power-generation systems are some of the ongoing challenges faced by modern power systems. Therefore, many efforts have been made by the scientific community to develop comprehensive solutions to overcome these issues. For instance, current technological advances have allowed the integration of distributed generators into the power systems, promoting the use of microgrids to overcome these issues. However, the use of renewable distributed generators have introduced new challenges to the traditional control system schemes. To overcome these challenges, a hierarchical control approach has been proposed for distributed renewable sources. In other words, the control scheme have been divided into three hierarchical levels, primary, secondary, and tertiary, to overcome the new challenges present in modern power systems. Due to extensiveness of this topic, this overview is focused on secondary control systems, mainly for AC isolated microgrids. To improve the power quality of modern systems, several secondary control schemes have been proposed to overcome the well-known problem of frequency and voltage deviation. Some of these schemes have also introduced adequate active/reactive power sharing techniques to optimize the utilization of resources. Additionally, other secondary control schemes have also focused on reducing the communication load, to lower the network cost and adding robustness against communication problems. This article presents an insight of the different control techniques used to overcome power quality and communication problems. A comprehensive overview of distributed secondary control techniques for islanded microgrids is presented. In addition, the implementation of these techniques is explained in an orderly and sequential manner.

14 SOLAR ENERGY↗

Mississippi State University Cooling, Heating, and Power (Micro-CHP) and Bio-Fuel Center

Between 2008 and 2014, the U.S. Department of Energy funded the MSU Micro-CHP and Bio-Fuel Center located at Mississippi State University. The overall objective of this project was to enable micro-CHP (micro-combined heat and power) utilization, to facilitate and promote the use of CHP systems and to educate architects, engineers, and agricultural producers and scientists on the benefits of CHP systems. Therefore, the work of the Center focused on the three areas: CHP system modeling and optimization, outreach, and research. In general, the results obtained from this project demonstrated that CHP systems are attractive because they can provide energy, environmental, and economic benefits. Some of these benefits include the potential to reduce operational cost, carbon dioxide emissions, primary energy consumption, and power reliability during electric grid disruptions. The knowledge disseminated in numerous journal and conference papers from the outcomes of this project is beneficial to engineers, architects, agricultural producers, scientists and the public in general who are interested in CHP technology and applications. In addition, more than 48 graduate students and 23 undergraduate students, benefited from the training and research performed in the MSU Micro-CHP and Bio-Fuel Center. The project scope consisted of six separate, but related areas: 1. Micro-CHP modeling - Computational simulations and verification/validation studies of selected models for technical and economic viability. 2. Fuel flexibility in micro-CHP applications – Demonstrating and quantifying the operation of micro-CHP systems on alternative fuels. 3. Outreach activities – Providing provide educational materials for engineers and architects and conducting outreach seminars, workshops, and demonstrations for engineers and architects as well as for more general audiences. 4. Biofuel and opportunity fuel processing and utilization – Determining the processing requirements and feasibility to utilize biofuels and disaster debris for micro-CHP systems. 5. CHP Systems Optimization – Optimization of internal combustion and Stirling engines integrated with heat recovery systems for CHP operation. 6. Distributed Generation and Grid Interconnection – Developing requirements and control systems for interconnection of micro-CHP systems with the electrical grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Retracted Article: Distributed energy management for networked microgrids in a three-phase unbalanced distribution network

Owing to increased penetration of three-phase and single-phase microgrids, distributed energy resources (DERs), and responsive loads, the maintenance of a three-phase balance by distribution networks is a significant challenge. Existing literature on distributed energy management for networked microgrids generally neglects the distribution network or employs a simplified phase balanced distribution network; thus, these evaluations are not applicable. Further, the underlying mutual coupling between the different phases of distribution feeders results in a more challenging situation. Here, to solve this issue, this study sought to propose distributed energy management based on a three-phase unbalanced distribution network. Various three-phase or single-phase microgrids, utility-owned DERs, and responsive loads were coordinated through iteratively adjusted price signals. Based on the price signals received, the microgrid controllers (MCs) and distribution management system (DMS) updated the schedules of the DERs and responsive loads under their jurisdiction separately. The price signals were then updated according to the generation-load mismatch at each node and distributed to the corresponding MCs and DMS for the next iteration. The iteration continued until a sufficiently small generation-load mismatch was achieved at all nodes, that is, a balanced generation and load at all nodes under the agreed price signals. Considering a three-phase unbalanced distribution network, the price signals were determined per phase per node. Overall, the proposed distributed energy management coordinates microgrids, utility-owned DERs, responsive loads with guaranteed network constraints, and preserves the privacy of microgrid customers. This distributed energy management method was further demonstrated through various case studies on a three-phase networked microgrid test system.