Search NASA⌕ Search

SEARCH · Search NASA

Results for “distribution system optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Electric Access System Enhancement (EASE): Assessment of a Distributed Energy Resource Management System for Enabling Dynamic Hosting Capacity

The Electric Access System Enhancement (EASE) project demonstrated a scalable, interoperable, and cost-effective means of integrating high penetration of distributed energy resources (DERs). The control architecture developed leveraged a Distributed Energy Resource Management System, Distribution System Operator for transacting energy, and 3rd Party DER Aggregator platform. The project identified ways to enhance the customer interconnection process to the grid and improve access to information from DERs and optimize the usage of DERs to provide energy services in a simulated day-ahead shadow market while maintain grid reliability. By integrating these capabilities into a scalable system of systems, the DSO can effectively balance DER generation and customer demand on the distribution network. This capability allows the grid to host more DER than traditionally possible on wires alone. Hosting more DER has the added benefit of supplying increased demand growth, sometimes beyond the capacity limits of the distribution network itself. This is known as a dynamic hosting capacity, which could help utilities manage the forecasted growth in electricity demand as California switch to electric vehicles and appliances. This could help to establish energy storage and PV generation as a “pseudo firm” generation resource mix if managed appropriately and provide sufficient resource adequacy for distribution capacity upgrade deferrals.

14 SOLAR ENERGY↗

Computing material volume fractions on a superimposed mesh as applied to Monte Carlo particle transport simulations

Here, we present a newly implemented ray tracing algorithm in OpenMC for efficiently computing material volume fractions on superimposed meshes in complex geometries. By firing rays along each coordinate direction through the geometry, the approach accumulates track-length data in each mesh element, thereby determining the fractional composition of each material. Scaling studies on three different models—a random tetrahedra configuration, the Frascati Neutron Generator ITER dose rate benchmark, and a stellarator design—show excellent parallel performance, with nearly linear speedup on modern multi-threaded and distributed-memory systems. An analysis of the residual error relative to high-resolution reference solutions demonstrated that under optimal conditions it decreases as 1/R, where R is the number of rays fired, making it straightforward to achieve user-prescribed accuracy. This new functionality enables practical, mesh-based approaches for detailed nuclear analyses in production Monte Carlo workflows without resorting to expensive, fully conformal or unstructured meshing.

Monte Carlo↗

An Online Joint Optimization–Estimation Architecture for Distribution Networks

Here in this article, we propose an optimal joint optimization-estimation architecture for distribution networks, which jointly solves the optimal power flow (OPF) problem and static state estimation (SE) problem through an online gradient-based feedback algorithm. The main objective is to enable a fast and timely interaction between the OPF decisions and state estimators with limited sensor measurements. First, convergence and optimality of the proposed algorithm are analytically established. Then, the proposed gradient-based algorithm is modified by introducing statistical information of the inherent estimation and linearization errors for an improved and robust performance of the online OPF decisions. Overall, the proposed method eliminates the traditional separation of operation and monitoring, where optimization and estimation usually operate at distinct layers and different time scales. Hence, it enables a computationally affordable, efficient, and robust online operational framework for distribution networks under time-varying settings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Asynchronous Iterative Solvers for Extreme-Scale Computing

The Asynchronous Iterative Solvers for Extreme-Scale Computing (AsyncIS) project aims to explore more efficient numerical algorithms by decreasing their overhead. AsyncIS does this by replacing the outer Krylov subspace solver with an asynchronous optimized Schwarz method, thereby removing the global synchronization and bulk synchronous operations typically used in numerical codes. AsyncIS—a U.S. Department of Energy (DOE)-funded collaboration between Georgia Tech, the University of Tennessee, Knoxville, Temple University, and Sandia National Laboratories—also focuses on the development and optimization of asynchronous preconditioners (i.e., preconditioners that are generated and/or applied in an asynchronous fashion). The novel preconditioning algorithms that provide fine-grained parallelism enable preconditioned Krylov solvers to run efficiently on large-scale distributed systems and manycore accelerators like GPUs.

97 MATHEMATICS AND COMPUTING↗

DLR Calculation Engine Interoperability Profile: A Project for the TOGETs Task Force

This document contains a detailed interoperability profile outlining how the components of the CIM can be used to implement DLR in support of the two use cases identified in the Use Case Document. An interoperability profile is defined by the Smart Electric Power Alliance (SEPA) as a document that “specifies standards-based requirements for interfaces or applications that are accepted by the user-community, testing authorities, and other stakeholders. It specifies configuration options within a standard’s requirements sufficient to deliver the desired level of interoperability and functionality.” To that end, this document is not in itself a standard, nor has it been approved by any formal body. Rather, it is an example of how to implement the CIM standard and has been reviewed by industry, including transmission operators and DLR vendors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Cross-Domain Optimization Framework of PMU and Communication Placement for Multidomain Resiliency and Cost Reduction

Phasor measurement units (PMUs) play a crucial role in real-time monitoring and control of power grids. They rely on a communication network to transfer measurement data to the phasor data concentrator (PDC) for further processing and analysis. In this paper, a resilient cross-domain PMU and communication link placement method for minimizing the overall installation cost of the wide-area measurement system (WAMS) is proposed. Here, the main idea is to break down the barrier between the power grid domain and the communication domain, and consider the impact of one when design the other. The PMU placement in the power grid domain takes into account the cost of communication links by generating multiple solutions with equally minimum PMU costs for communication link placement evaluation. On the other hand, the communication link placement problem reduces the cost by customizing the routing policies based on the different roles of PMUs in grid observability. The proposed WAMS design is capable of withstanding any single component failure in the power domain (PMU failure or power branch failure) or in the communication domain (communication link failure or PDC failure). Numerical study on the IEEE 57-bus system reveals that the developed cross-domain optimization framework can significantly reduce the overall installation cost of WAMS while attaining multi-domain resiliency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analytic Neural Network Gaussian Process Enabled Chance-Constrained Voltage Regulation for Active Distribution Systems with PVs, Batteries and EVs

This paper proposes an analytic neural network Gaussian process (NNGP)-based chance-constrained real-time voltage regulation method for active distribution systems with photovoltaics (PVs), batteries, and electric vehicles (EVs). NNGP can utilize historical measurement data to achieve real-time probabilistic node voltage estimation through Bayesian inference. Then, NNGP is fully analytically embedded into the optimal power flow model to perform voltage regulation and adapt to various topological changes. The uncertainties of voltage estimations are easily considered via the chance constraint, and it has been shown that the adoption of this chance constraint can significantly improve the reliability of voltage regulation under various scenarios. The comparison results with other methods, carried out on a real 759-node distribution system located in western Colorado, U.S., show that the proposed method can achieve accurate voltage estimation across different topologies and reliably perform voltage regulation considering PVs, batteries, and EVs.

active distribution systems↗

Electric Water Heaters for Transactive Systems: Model Evaluations and Performance Quantification

Electric water heaters (EWHs) are opportune appliances for implementing demand-side control. EWH models serve as a fundamental step toward accurately estimating EWH flexibility potential and designing proper control strategies. Existing studies have adapted numerous modeling approaches in evaluating the potential of EWHs for a variety of grid applications. This paper presents an analytical study that evaluates the performance of state-of-art EWH models in terms of accuracy and computational complexity for adaptation in evaluation studies for the transactive system. The work proposes a transactive control strategy that optimally utilizes the thermal inertia of EWHs for providing grid services. Here, the performance of the control strategy and the impact of modeling accuracy is evaluated for device-level and feeder-level use cases using the IEEE 123 node test distribution system appropriately populated with EWHs. The simulation results illustrate the effectiveness of the control strategy in reducing the feeder demand during peak period by 13% and also quantities the impact of using simplified modeling approaches for determining the potential of EWHs for providing grid services.

42 ENGINEERING↗

A System of Agents for Supporting Optimization and Control of a Connected Community

The residential sector consumes a significant portion of the electricity sold in the United States. Above 60% of the energy used in the sector is used to operate heating, ventilation, and air conditioning (HVAC) systems and water heating (WH) systems. With the increase of intelligence in the grid and the new decision and control options enabled by the Internet of Things; control of these devices can be used to support the grid. Therefore, this article presents a scalable multiagent system for optimizing HVAC and WH systems while maintaining comfort. It allows a utility to orchestrate the shifting of energy from critical periods without direct control, but instead by using a price signal. The architecture, optimization formulation, implementation strategy and results from an implementation project are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of the feedstock supply for siting single- and multiple-feedstock biorefineries in the USA and identification of prevalent feedstocks

An integrated multi-feedstock bioenergy (i.e., biofuel, biopower, or bioproduct) supply system has potential to reduce biomass supply system uncertainties and costs. This study identifies optimal configurations of multi-feedstock biomass-to-biorefinery supply chains and pertinent feedstock combinations based on spatial distribution of feedstock and lowest delivered cost to the biorefinery. We used the Supply Characterization Model (SCM) to allocate feedstock supplies to candidate biorefinery facilities. Model runs were performed for herbaceous energy crops, agriculture residue, and woody biomass available in 2017, 2022, 2025, and 2030 as estimated by the Policy Analysis System (POLYSYS) and Forest Sustainable and Economic Analysis Model (ForSEAM) models. Three feedstock supply scenarios were compared: (a) an herbaceous scenario: switchgrass, miscanthus, biosorghum, and corn stover; (b) a woody scenario: coppice wood, noncoppice wood, whole trees, and forestry residues, and (c) a mixed scenario: a combination of all feedstocks in herbaceous and woody scenarios. By 2030 the analyses predicted that 323, 168, and 473 biorefineries were sited in the herbaceous, woody, and mixed scenario, respectively, in the conterminous USA. Feedstock mixes supplied to the biorefineries were mostly dominated by a single feedstock. The most prominent feedstock mixes identified were: (1) switchgrass and miscanthus; (2) coppice and noncoppice wood; and (3) coppice wood, noncoppice wood, switchgrass and miscanthus. Biorefineries using multi-feedstock would be beneficial for growth of bioeconomy, however flexible and cost-effective conversion platforms should be developed to efficiently utilize multiple feedstocks. This analysis identifies biorefinery locations and feedstock supply mixes while minimizing delivered feedstock costs based on spatial and temporal feedstock availability.

09 BIOMASS FUELS↗

To What Extent Will Decarbonization Deepen the Conversation Between Industry and the Grid?

Decarbonization - the transition away from un-mitigated fossil fuel combustion throughout the economy - requires big changes from both power and process systems. On the power system side, those changes are expected to include large increases in variable generation, e.g., from wind and solar, which has near-zero marginal costs and at large shares can produce infrequent but consequential energy droughts. On the process systems side, industries are investigating their options for direct and indirect electrification, the latter exemplified by replacing fossil fuel inputs with zero-carbon, energy-carrying chemicals like hydrogen and ammonia produced via electrochemical processes. The economic features of these changes within the larger context of power and process systems suggest that their realization could be accompanied by a paradigm shift in how industrial facilities interact with the grid. For example, the dominant type of demand participation in power markets could change from today's focus on load reductions at peak times to a new focus on shifting electricity use, enabled in part by large-scale product storage, to take advantage of renewable energy that would otherwise be curtailed and to avoid consumption during high-price energy droughts. This talk will describe these and other possible design and operational approaches from grid and industrial economic perspectives, culminating in an enumeration of open problems that lie at the interface of today and tomorrow's power and process systems.

co-design↗

Perturbation-Based Diagnosis of False Data Injection Attack Using Distributed Energy Resources

Modern smart grid relies on various sensor measurements for its operational control. In a successful false data injection attack, the attacker manipulates the measurements from the grid sensors such that undetected errors are introduced into the estimates of the system parameters leading to catastrophic situations. This paper proposes a novel perturbation based false data injection attack detection mechanism that utilizes inverter based distributed energy resources (DERs) to create low magnitude perturbation signal in the distribution system voltage that is inconsequential to the normal grid operation. Two voltage sensitivity analysis based algorithms are designed to identify the optimal set of DERs that can create the voltage perturbation signal of desired magnitude. An analytical method of voltage sensitivity analysis is used to compute the magnitude of voltage perturbation signal at each node in a computationally efficient manner. Then, a detection mechanism is developed that checks for the presence of the perturbation sequence in each sensor measurement. A sensor measurement is deemed authentic if the voltage perturbation signal is present in the data. In case of sensor malfunction or cyber-attack, the perturbation signal will not be present in the measurement data. Performance of the proposed attack detection mechanism is validated via simulation of the IEEE 69 bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms

The “Modular HF Isolated MV String Inverters Enable a New Paradigm for Large PV Farms” project focuses on exploring alternative power converter and system-level plant configurations to achieve the lowest cost and highest energy output for a given solar plus storage (e.g., PV + battery) plant, including the use of medium voltage (MV) collection while taking into account detailed models of all elements. To realize this objective, four approaches were utilized (i) employ a novel Medium Voltage String Inverter (MVSI) topology (soft switching solid state transformer – S4T) to convert 1000 Vdc to 4.16 kVac; (ii) plant collection using standard, low-cost overhead MV distribution network; (iii) enable energy storage integration without additional converter cost to achieve dispatchability of the PV resource; and (iv) provide advanced functionality (autonomous operation, track ISO signals for dynamic balancing and ancillary services, and PV farm operation as a virtual grid resource). Subsequently and in alignment with the previously mentioned approaches, the project was structured in five efforts (i) S4T MVSI simulation and design; (ii) system analysis and storage optimization; (iii) financial analysis; (iv) power converter prototype build and test; and (v) regulatory and commercial impact study. The outcomes provided by each effort can be summarized as follows (i) Project explored the use of MV AC distribution architecture for hybrid PV+storage utility-scale PV farms; (ii) Detailed loss and LCOE analysis for AC and DC side BESS architecture, including multiple converter topologies, as well as for proposed MVSI/MDCT systems; (iii) MVSI was built and holds promise but needs lower-cost high-voltage Si-C devices, which does not seem possible in the near term; (iv) MDCT provides a simpler modular building block – validated through HIL and farm level modeling, simulation and experimental validation; (v) 300 kVA MDCT prototype built and tested, technology is being commercialized; and (vi) Regulatory model of utility building PV plants, where PV panels are treated as DC generation (IPP), seems viable and can allow improved grid integration.

14 SOLAR ENERGY↗

Grid Modernization of Cooperatives and Municipal Utilities via Breakthrough System Monitoring, Control and Optimization (CRADA Final Report)

This project aims at developing and demonstrating successful implementation of breakthrough approaches in real-time data visualization as well as real-time distributed DER control and optimization to provide ample benefits to both utilities and end users. The National Renewable Energy Laboratory (NREL), Holy Cross Energy (HCE), National Rural Electric Cooperative Association (NRECA) and Survalent are collaborating to enable Cooperative and Municipal utilities to fully leverage DERs as part of their strategies for providing safe, reliable, and affordable electric services to their customers and help meet DOE Grid modernization goal of achieving at least 10% active devices to provide grid flexibility by 2035. This project will use novel real-time control algorithms and approaches for distributed control recently developed under DOE-funded projects, using the date from the Survalent’s basic SCADA engine, GIS and AMI engines deployed at HCE combined with NRECA’s globally-used MultiSpeak(R) software interoperability specification for seamless and real-time communications between electric utility enterprise software to embrace DER as part of their strategies for providing safe, reliable and affordable electric service to their customers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Model-Predictive Hierarchical-Control Framework for Aggregating Residential DERs to Provide Grid Regulation Services

This paper develops a hierarchical control frame-work to aggregate and to manage behind-the-meter distributed energy resources (DERs), which will be ubiquitous in future distribution systems. In the proposed framework, firstly, each controller in the hierarchy determines the flexibility of the DERs such that the obtained flexibility is feasible with respect to its operational purview. For example, the operational purview of a home energy management system may only consider consumer comfort preferences, while that for an aggregator or a grid controller may consider network voltage management as well. Based on the feasible flexibility, optimal setpoints for the DERs is then determined by the hierarchical controllers to help the distribution power network in voltage regulation, coordination issues with existing transmission-level conventional generators, etc. Therefore, the proposed strategy, which is based on model-predictive control, can be effectively utilized by the distribution network to coordinate several DERs to provide grid regulation services. Numerical simulations performed on the IEEE 37-bus test system demonstrate the efficacy of the proposed approach.

behind-the-meter↗

A Model-Predictive Hierarchical-Control Framework for Aggregating Residential DERs to Provide Grid Regulation Services

This paper develops a hierarchical control frame-work to aggregate and to manage behind-the-meter distributed energy resources (DERs), which will be ubiquitous in future distribution systems. In the proposed framework, firstly, each controller in the hierarchy determines the flexibility of the DERs such that the obtained flexibility is feasible with respect to its operational purview. For example, the operational purview of a home energy management system may only consider consumer comfort preferences, while that for an aggregator or a grid controller may consider network voltage management as well. Based on the feasible flexibility, optimal setpoints for the DERs is then determined by the hierarchical controllers to help the distribution power network in voltage regulation, coordination issues with existing transmission-level conventional generators, etc. Therefore, the proposed strategy, which is based on model-predictive control, can be effectively utilized by the distribution network to coordinate several DERs to provide grid regulation services. Numerical simulations performed on the IEEE 37-bus test system demonstrate the efficacy of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Linkages Between NREL's dGen, REopt, and SAM Models

This webinar describes linkages between NREL's dGen, SAM, and REopt tools that were developed as a part of the RiDER project, including specifying utility rates in the SAM GUI and using them in dGen adoption analysis, and using REopt to determine optimal system sizes for dGen agents.

dGen↗