Search NASA⌕ Search

SEARCH · Search NASA

Results for “efficient envelope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Chapter 7: Principles of Northern Housing Design with Examples from Alaska

The Arctic has unique challenges and needs with respect to housing due to extreme climate, remoteness of communities, cultural aspects, and other factors. Attempts to adopt designs from other regions often resulted in failures, such as rotten building envelopes or features incompatible with local values. The main goal of this chapter is to inform a broad audience involved in northern housing about basic principles important for the Arctic. Particular attention is given to energy efficiency, health and durability, foundations appropriate for the underlying terrain such as permafrost, inclusive design process to assure meeting cultural and other needs and building design factoring in seasonality and logistical challenges of remote communities. Examples of existing prototype homes are given throughout the chapter to demonstrate how the individual principles can be successfully applied in real-life scenarios. This chapter also covers current trends, what the future might look like, how it is informed by indigenous perspectives, and how northern housing design can influence approaches in other regions of the world. The ultimate goal is to contribute to a vibrant future of communities in the Arctic and beyond.

Arctic↗

The effect of building retrofit measures on CO2 emission reduction – A case study with U.S. Medium office buildings

Building retrofit has great potential to reduce CO2 emissions since buildings are responsible for 36% of emissions in the United States. Several existing studies have examined the effect of building retrofit measures on CO2 emission reduction. However, these studies oversimplified emission factors of electricity by adopting constant annual emission factors. This study uses hourly emission factors of electricity to analyze the effect of building retrofit measures on emission reduction using U.S. medium office buildings as an example. We analyzed CO2 emission reduction effects of eight building retrofit measures that related to envelop and mechanical system in five locations: Tampa, San Diego, Denver, Great Falls, and International Falls. The main findings are: (1) estimating CO2 emission reduction with constant emission factors overestimates the emission reduction for most measures in San Diego, while it underestimates the emission reduction for most measures in Denver and International Falls; (2) The same retrofit measure may have different effects in CO2 emission reduction depending on the climates. For instance, improving lighting efficiency and improving equipment efficiency have less impacts in emission reduction in cold climates than hot climates; and (3) The most energy efficient measure may not be the most emission efficient measure. For example, in Great Falls, the most energy efficient measure is improving equipment efficiency, but the most emission efficient measure is improving heating efficiency.

Lou, Yingli↗

Potential benefits of cool walls on residential and commercial buildings across California and the United States: Conserving energy, saving money, and reducing emission of greenhouse gases and air pollutants

Solar-reflective “cool” walls reduce absorption of sunlight by the building envelope, which may decrease cooling load in warm weather and increase heating load in cool weather. Changes to annual heating, ventilation, and air conditioning (HVAC) energy use depend on climate, wall construction, wall orientation, building geometry, HVAC efficiency, and operating schedule. Changes to annual energy cost and energy-related emissions further vary with local energy prices and emission factors. In this work, we used EnergyPlus to perform over 100,000 whole-building energy simulations, spanning 10 different building categories, three building vintages, 16 California climate zones, and 15 United States (U.S.) climate zones. We find that cool walls yielded annual source energy, energy cost, and emission savings in all California climate zones and in warm U.S. (ASHRAE) climate zones. In California, annual whole-building HVAC energy cost savings were 4.0–27% in single-family homes, 0.5–3.8% in medium office buildings, and 0.0–8.5% in stand-alone retail stores. In warm U.S. climates—zones 1A (Miami, FL) through 4B (Albuquerque, NM)—annual HVAC energy cost savings were 1.8–8.3% in single-family homes, 0.3–4.6% in medium office buildings, and 0.5–11% in stand-alone retail stores. California and U.S. fractional source energy and emission savings were comparable to fractional energy cost savings. Per unit surface area modified, cool-wall savings often exceeded cool-roof savings because building codes typically prescribe much less wall insulation than roof insulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RDI's Wisdom Way Solar Village Final Report: Includes Utility Bill Analysis of Occupied Homes

In 2010, Rural Development, Inc. (RDI) completed construction of Wisdom Way Solar Village (WWSV), a community of ten duplexes (20 homes) in Greenfield, MA. RDI was committed to very low energy use from the beginning of the design process throughout construction. Key features include: 1. Careful site plan so that all homes have solar access (for active and passive); 2. Cellulose insulation providing R-40 walls, R-50 ceiling, and R-40 floors; 3. Triple-pane windows; 4. Airtight construction (~0.1 CFM 50 /ft 2 enclosure area); 5. Solar water heating systems with tankless, gas, auxiliary heaters; 6. PV systems (2.8 or 3.4kW STC ); 7. 2-4 bedrooms, 1,100-1,700 ft 2 . The design heating loads in the homes were so small that each home is heated with a single, sealed-combustion, natural gas room heater. The cost savings from the simple HVAC systems made possible the tremendous investments in the homes' envelopes. The Consortium for Advanced Residential Buildings (CARB) monitored temperatures and comfort in several homes during the winter of 2009-2010. In the Spring of 2011, CARB obtained utility bill information from 13 occupied homes. Because of efficient lights, appliances, and conscientious home occupants, the energy generated by the solar electric systems exceeded the electric energy used in most homes. Most homes, in fact, had a net credit from the electric utility over the course of a year. On the natural gas side, total gas costs averaged $|$$377 per year (for heating, water heating, cooking, and clothes drying). Total energy costs were even less - $\$$337 per year, including all utility fees. The highest annual energy bill for any home evaluated was $\$$458; the lowest was $\$$171.

14 SOLAR ENERGY↗

Renewable Energy Requirements for Future Building Codes: Energy Generation and Economic Analysis

As the model energy codes are improved to reach efficiency levels 50 percent greater than current codes, installation of on-site renewable energy generation is likely to become a code requirement. This requirement will be needed because traditional mechanisms for code improvement, including the building envelope, mechanical systems, and lighting, have been maximized at the most cost-effective limit.

energy codes↗

TOI-1235 b: A Keystone Super-Earth for Testing Radius Valley Emergence Models around Early M Dwarfs

Small planets on close-in orbits tend to exhibit envelope mass fractions of either effectively zero or up to a few percent depending on their size and orbital period. Models of thermally driven atmospheric mass loss and of terrestrial planet formation in a gas-poor environment make distinct predictions regarding the location of this rocky/nonrocky transition in period–radius space. Here we present the confirmation of TOI-1235 b (P = 3.44 days, r{sub p}=1.738{sub −0.076}{sup +0.087} R{sub ⊕}), a planet whose size and period are intermediate between the competing model predictions, thus making the system an important test case for emergence models of the rocky/nonrocky transition around early M dwarfs (R {sub s} = 0.630 ± 0.015 R{sub ⊙}, M {sub s} = 0.640 ± 0.016 M{sub ⊙}). We confirm the TESS planet discovery using reconnaissance spectroscopy, ground-based photometry, high-resolution imaging, and a set of 38 precise radial velocities (RVs) from HARPS-N and HIRES. We measure a planet mass of 6.91{sub −0.85}{sup +0.75} M{sub ⊕}, which implies an iron core mass fraction of 20{sub −12}{sup +15}% in the absence of a gaseous envelope. The bulk composition of TOI-1235 b is therefore consistent with being Earth-like, and we constrain an H/He envelope mass fraction to be <0.5% at 90% confidence. Our results are consistent with model predictions from thermally driven atmospheric mass loss but not with gas-poor formation, suggesting that the former class of processes remains efficient at sculpting close-in planets around early M dwarfs. Our RV analysis also reveals a strong periodicity close to the first harmonic of the photometrically determined stellar rotation period that we treat as stellar activity, despite other lines of evidence favoring a planetary origin (P=21.8{sub −0.8}{sup +0.9} days, m{sub p}sin i=13.0{sub −5.3}{sup +3.8} M{sub ⊕}) that cannot be firmly ruled out by our data.

79 ASTRONOMY AND ASTROPHYSICS↗

Moisture Transfer in Commercial Buildings Due to Air Leakage: A New Feature in the Online Airtightness Savings Calculator

Air leakage through the building envelopes is responsible for a large amount of energy use. The US Department of Energy Windows and Building Envelope Research and Development Roadmap for Emerging Technologies states that, in 2010, air infiltration was responsible for 20% of primary energy consumption attributable to the fenestration and building envelopes of commercial buildings. Despite this fact, improving airtightness is not always recognized by commercial building owners, as they have been slow in acknowledging and diminishing the detrimental effects of air leakage on energy use, comfort, indoor air quality, and building material durability.The design and construction industry would benefit from a credible, easy-to-use tool that estimates potential energy and financial savings in a standardized manner so designers and contractors can give building owners compelling reasons to invest in reducing air leakage. In 2016–2017, Oak Ridge National Laboratory, the National Institute of Standards and Technology, the Air Barrier Association of America, and the US-China Clean Energy Research Center for Building Energy Efficiency collaborated to develop an online calculator. This user-friendly calculator is free to the public and uses the simulation results of the whole building energy simulation tool EnergyPlus and the airflow simulation tool CONTAM. In 2018–2019, the calculator was expanded to add moisture transfer calculations given that air leakage through the building envelope can have a significant impact on moisture transfer and associated impacts. Four more commercial building types were also added to the existing database of three building types as part of this update. This paper describes the procedure used to calculate moisture transfer due to air leakage and provides examples that demonstrate the moisture transfer for each of the seven commercial building types that are currently part of the calculator.

Shrestha, Som↗

High Performance Homes That Use 50% Less Energy Than the DOE Building America Benchmark Building

This document describes lessons learned from designing, building, and monitoring five affordable, energy-efficient test houses in a single development in the Tennessee Valley Authority (TVA) service area. This work was done through a collaboration of Habitat for Humanity Loudon County, the US Department of Energy (DOE), TVA, and Oak Ridge National Laboratory (ORNL).The houses were designed by a team led by ORNL and were constructed by Habitat's volunteers in Lenoir City, Tennessee. ZEH5, a two-story house and the last of the five test houses to be built, provided an excellent model for conducting research on affordable high-performance houses. The impressively low energy bills for this house have generated considerable interest from builders and homeowners around the country who wanted a similar home design that could be adapted to different climates. Because a design developed without the project constraints of ZEH5 would have more appeal for the mass market, plans for two houses were developed from ZEH5: a one-story design (ZEH6) and a two-story design (ZEH7). This report focuses on ZEH6, identical to ZEH5 except that the geothermal heat pump is replaced with a SEER 16 air source unit (like that used in ZEH4). The report also contains plans for the ZEH6 house. ZEH5 and ZEH6 both use 50% less energy than the DOE Building America protocol for energyefficient buildings. ZEH5 is a 4 bedroom, 2.5 bath, 2632 ft2 house with a home energy rating system (HERS) index of 43, which qualifies it for federal energy-efficiency incentives (a HERS rating of 0 is a zero-energy house, and a conventional new house would have a HERS rating of 100). This report is intended to help builders and homeowners build similar high-performance houses. Detailed specifications for the envelope and the equipment used in ZEH5 are compared with the Building America Benchmark building, and detailed drawings, specifications, and lessons learned in the construction and analysis of data gleaned from 94 sensors installed in ZEH5 to monitor electric sub-metered usage, temperature and relative humidity, hot water usage, and heat pump operation for 1 year are presented. This information should be particularly useful to those considering structural insulated panel (SIP) walls and roofing; foundation geothermal heat pumps for space heating and cooling; solar water heaters; and roof-mounted, grid-tied photovoltaic systems. The document includes plans for ZEH6 (adapted from ZEH5), a one-story, high-performance house, as well as projections of how the design might perform in five major metropolitan areas across the TVA service territory. The HERS ratings for this all-electric house vary from 36 (Memphis, Tennessee) to 46 (Bristol, Tennessee).

14 SOLAR ENERGY↗

Integrated and Optimized Energy-Efficient Construction Package for a Community of Production Homes in the Mixed-Humid Climate

This research high performance home analyzes how a set of advanced technologies can be integrated into a durable and energy-efficient house in the mixed-humid climate while remaining affordable to homeowners. The technical solutions documented in this report are the cornerstone of the builder's entire business model based on delivering high-performance homes on a production basis as a standard product offering to all price segments of the residential market. Home Innovation Research Labs partnered with production builder Nexus EnergyHomes (CZ 4) and they plan to adopt the successful components of the energy solution package for all 55 homes in the community. The research objective was to optimize the builder's energy solution package based on energy performance and construction costs. All of the major construction features, including envelope upgrades, space conditioning system, hot water system, and solar electric system were analyzed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Influence of the Hall Term on the Development of Magnetized Laser-Produced Plasma Jets

We present 2D axisymmetric simulation results describing the influence of the Hall term on laser-produced plasma jets and their interaction with an applied magnetic field parallel to the laser axis. Bending of the poloidal B-field lines produces an MHD shock structure surrounding a conical cavity, and a jet is produced from the convergence of the shock envelope. Both the jet and the conical cavity underneath it are bound by fast MHD shocks. We compare the MHD results generated using the extended-MHD code Physics as an Extended-MHD Relaxation System with an Efficient Upwind Scheme (PERSEUS) with MHD results generated using GORGON and find reasonable agreement. We then present extended-MHD results generated using PERSEUS, which show that the Hall term has several effects on the plasma jet evolution. A hot low-density current-carrying layer of plasma develops just outside the plume, which results in a helical rather than a purely poloidal B-field, and reduces magnetic stresses, resulting in delayed flow convergence and jet formation. The flow is partially frozen into the helical field, resulting in azimuthal rotation of the jet. The Hall term also produces field-aligned current in strongly magnetized regions. In particular, we find the influence of Hall physics on this problem to be scale-dependent. In conclusion, this points to the importance of mitigating the Hall effect in a laboratory setup, by increasing the jet density and system dimensions, in order to avoid inaccurate extrapolation to astrophysical scales.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation Speed Analysis and Improvements of Modelica Models for Building Energy Simulation

This paper presents an approach for speeding up Modelica models. Insight is provided into how Modelica models are solved and what determines the tool’s computational speed. Aspects such as algebraic loops, code efficiency and integrator choice are discussed. This is illustrated using simple building simulation examples and Dymola. The generality of the work is in some cases verified using OpenModelica. Using this approach, a medium sized office building including building envelope, heating ventilation and air conditioning (HVAC) systems and control strategy can be simulated at a speed five hundred times faster than real time.

Jorissen, Filip↗

Machine Learning for Automated Extraction of Building Geometry

As data science comes to buildings, the promise of using machine learning and novel sources of data has received much attention. Advances in machine learning and computer vision algorithms, combined with increased access to unstructured data (e.g., images and text), have created an opportunity for automated extraction of building characteristics – cost-effectively, and at scale. Acquisition of features such as footprint are time consuming and costly to acquire with today’s manual methods, but can be streamlined through intelligent software-based solutions applied to satellite images. When combined with aerial RGB and thermal images, full 3D geometries and thermal maps can be constructed to determine additional characteristics such as window to wall ratio, height, number of stories and envelope thermal characteristics. In this paper we present three contributions to accelerate these high potential opportunities: (1) a methodical analysis of how these features can be integrated into today’s simulation and data driven software tools to enhance efficiency measure identification and owner/operator decision making; (2) development and accuracy testing of open source deep neural network methods to extract building footprints from satellite imagery, including the curation and application of openly available GIS datasets for training and continued development by others; and (3) an open framework for drone-based image capture and creation of 3D building geometries. This work represents an important bridge between high-level studies that span diverse application areas and those that detail point solutions yet cannot be easily replicated or extended.

Touzani, Samir↗

The Formation of Uranus and Neptune: Fine-tuning in Core Accretion

Uranus and Neptune are ice giants with ∼15% atmospheres by mass, which places them in a category intermediate between rocky planets and gas giants. These atmospheres are too massive to have been primarily outgassed, but they never underwent runaway gas accretion. The ice giants never reached critical core mass (M{sub crit}) in a full gas disk, but their cores are ≳M{sub crit}, suggesting that their envelopes were mainly accreted at the end of the disk lifetime. Pebble accretion calls into question traditional slow atmospheric growth during this phase. We show that the full-sized ice giants predominantly accreted gas from a disk depleted by at least a factor of ∼100. Such a disk dissipates in ≲10{sup 5} years. Why would both cores stay subcritical for the entire ∼Myr disk lifetime, only to reach M{sub crit} in the final 10{sup 5} years? This is fine tuned. Ice giants in the outer disk have atmospheric mass fractions comparable to the disk gas-to-solid ratio during the bulk of their gas accretion. This point in disk evolution coincides with a dynamical upheaval: the gas loses its ability to efficiently damp the core random velocities, allowing them to be gravitationally excited by Jupiter and Saturn. We suggest that the ice giants’ cores began growing on closer-in orbits (staying subcritical), and migrated out during this dynamical instability. There, their orbits circularized after accreting much of their mass in solids. Finally, they accreted their envelopes from a depleted nebula, where the sparseness of feeding-zone gas prevented runaway.

79 ASTRONOMY AND ASTROPHYSICS↗

INTERACTION OF CLOSE-IN PLANETS WITH THE MAGNETOSPHERE OF THEIR HOST STARS. II. SUPER-EARTHS AS UNIPOLAR INDUCTORS AND THEIR ORBITAL EVOLUTION

Planets with several Earth masses and orbital periods of a few days have been discovered through radial velocity and transit surveys. Regardless of their formation mechanism, an important evolution issue is the efficiency of their retention in the proximity of their host stars. If these 'super-Earths' attained their present-day orbits during or shortly after the T Tauri phase of their host stars, a large fraction of these planets would have encountered an intense stellar magnetic field. These rocky planets have a higher conductivity than the atmosphere of their host stars and, therefore, the magnetic flux tube connecting them would slip though the envelope of the host stars faster than across the planets. The induced electromotive force across the planet's diameter leads to a potential drop which propagates along a flux tube away from the planet with an Alfven speed. The foot of the flux tube would sweep across the stellar surface and the potential drop across the field lines drives a DC current analogous to that proposed for the electrodynamics of the Io-Jupiter system. The ohmic dissipation of this current produces potentially observable hot spots in the star envelope. It also heats the planet and leads to a torque which drives the planet's orbit to evolve toward both circularization and a state of synchronization with the spin of the star. The net effect is the damping of the planet's orbital eccentricity. Around slowly (or rapidly) spinning stars, this process also causes rocky planets with periods less than a few days to undergo orbital decay (or expansion/stagnation) within a few Myr. In principle, this effect can determine the retention efficiency of short-period hot Earths. We also estimate the ohmic dissipation interior to these planets and show that it can lead to severe structure evolution and potential loss of volatile material in them. However, these effects may be significantly weakened by the reconnection of the induced field.

79 ASTRONOMY AND ASTROPHYSICS↗

PROTOSTELLAR FEEDBACK AND FINAL MASS OF THE SECOND-GENERATION PRIMORDIAL STARS

The first stars in the universe ionized the ambient primordial gas through various feedback processes. 'Second-generation' primordial stars potentially form from this disturbed gas after its recombination. In this Letter, we study the late formation stage of such second-generation stars, where a large amount of gas accretes onto the protostar and the final stellar mass is determined when the accretion terminates. We directly compute the complex interplay between the accretion flow and stellar ultraviolet (UV) radiation, performing radiation-hydrodynamic simulations coupled with stellar evolution calculations. Because of more efficient H{sub 2} and HD cooling in the pre-stellar stage, the accretion rates onto the star are 10 times lower than in the case of the formation of the first stars. The lower accretion rates and envelope density result in the occurrence of an expanding bipolar H II region at a lower protostellar mass M{sub *} {approx_equal} 10 M{sub Sun }, which blows out the circumstellar material, thereby quenching the mass supply from the envelope to the accretion disk. At the same time the disk loses mass due to photoevaporation by the growing star. In our fiducial case the stellar UV feedback terminates mass accretion onto the star at M{sub *} {approx_equal} 17 M{sub Sun }. Although the derived masses of the second-generation primordial stars are systematically lower than those of the first generation, the difference is within a factor of only a few. Our results suggest a new scenario, whereby the majority of the primordial stars are born as massive stars with tens of solar masses, regardless of their generations.

79 ASTRONOMY AND ASTROPHYSICS↗

Exploration of Domain Aware Machine Learning for Grid Analytics: Transfer-Learnt Energy Models to Assist Buildings Control with Sparse Field Data

Buildings are a primary consumer of energy in the United States and are also increasingly being perceived as providers of grid services such as load shifting, shedding and modulation. High fidelity models of building energy consumption are needed to set appropriate baselines for measurement and verification (M&V) of controllers designed for energy efficient operation of buildings and to enable buildings to provide grid services via. participation in demand response programs. State-of-the-art building energy modeling techniques either rely on Physics based models, or extensive instrumentation of the building envelope to gather “big” data to train machine learning based models such as deep neural networks. While Physics based models are often limited by their accuracy, it is not always feasible to gather a significant amount of field data required to train machine learning based models with sufficient accuracy. In this paper, we explore the use of transfer learning-based strategies to address unsatisfactory accuracy of models for estimating building energy consumption when available field data for training is sparse or of unacceptable quality. In particular, we transfer knowledge in the form of data and parameters, from Physics based simulation frameworks to the field to improve the model accuracy, thus resulting in a Physics-informed Machine Learning framework. We evaluated the efficacy of our approach on field data collected from six commercial buildings and our results indicate that the proposed transfer learning based models provide comparative (and in some cases better) accuracy than state-of-the-art machine learning and deep learning solutions, with just one month of field data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Energy Asset Score for Architects

The Building Energy Asset Score is a national standardized tool for evaluating the physical and structural energy efficiency of commercial and multifamily residential buildings. The Asset Score generates a simple energy efficiency rating that enables comparison among buildings, and identifies opportunities for users to invest in energy efficiency upgrades. It is web-based and free to use. This fact sheet discusses the value of the score for architects.

Building energy simulation, building envelope, hot↗

Organic Rankine Cycle Integration and Optimization for High Efficiency CHP Genset Systems (Final Technical Report)

This project successfully advanced the integration of Organic Rankine Cycle (ORC) technology with reciprocating engine–based combined heat and power (CHP) systems to improve electrical efficiency, total CHP efficiency, and grid-responsive operation. Over three budget periods, the work progressed from high-temperature ORC component development and thermodynamic model validation to next-generation system design, working fluid transition, and techno-economic analysis. Key technical accomplishments include development and validation of a thermodynamic model capable of accurately predicting ORC performance across an expanded temperature and pressure envelope; successful identification and validation of low-global-warming-potential (GWP) working fluids—most notably R1233zd(E)—as viable replacements for R245fa; and demonstration of scalable ORC architectures suitable for integration with 1–20 MW class reciprocating engines. These advances enable flexible CHP configurations that can increase electrical output while maintaining high overall utilization of available thermal energy. The project also produced a clean-sheet design for a next-generation ORC system targeting substantially higher power output per unit, supported by detailed component selection, heat exchanger evaluation, and system-level modeling. Techno-economic analyses indicate that ORC-enabled flexible CHP systems can meet or exceed Department of Energy (DOE) efficiency targets while providing value to both facility operators and the electric grid.. Late-stage testing of the largest next-generation ORC prototype identified limitations related to pump net positive suction head (NPSH) requirements and condenser flooding under certain operating conditions. Although these issues constrained full validation of that configuration within the project timeframe, they provided clear and actionable design guidance for future system refinements. Importantly, validated modeling, smaller-scale testing, and working fluid evaluations confirmed the technical viability of the overall approach. In aggregate, this project met its core objectives by establishing validated design tools, de-risking key ORC technologies for CHP applications, and defining a credible pathway toward commercialization of flexible, high-efficiency CHP systems. The results form a strong foundation for continued development and deployment beyond the conclusion of the DOE-funded effort.

20 FOSSIL-FUELED POWER PLANTS↗