Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Performance Study of K2CsSb Photocathode inside a DC High Voltage Gun

In the past decade, there has been considerable interest in the generation of tens of mA average current in a photoinjector. Until recently, GaAs:Cs cathodes and K2CsSb cathodes have been tested successfully in DC and RF injectors respectively for this application. Our goal is to test the GaAs:Cs in RF injector and the K2CsSb cathode in the DC gun in order to widen our choices. Since the multialkali cathode is a compound with uniform stochiometry over its entire thickness, we anticipate that the life time issues seen in GaAs:Cs due surface damage by ion bombardment would be minimized with this material. Hence successful operation of the K2CsSb cathode in DC gun could lead to a relatively robust electron source capable of delivering ampere level currents. In order to test the performance of K2CsSb cathode in a DC gun, we have designed and built a load lock system that would allow the fabrication of the cathode at BNL and its testing at JLab. In this paper, we will present the design of the load-lock system, cathode fabrication, and the cathode performance in the preparation chamber and in the DC gun.

43 PARTICLE ACCELERATORS↗

Cryogenic system for BERLinPro

In 2010 Helmholtz-Zentrum Berlin (HZB) received funding to design and build the Berlin Energy Recovery Linac Project BERLinPro. The goal of this compact Energy recovery linac (ERL) is to develop the accelerator physics and technology required to generate and accelerate a 100-mA, 1-mm mrad emittance electron beam. The BERLinPro know-how can then be transferred to various ERL-based applications. All accelerating RF cavities including the electron source are based on superconducting technology operated at 1.8 K. A Linde L700 helium liquefier is supplying 4.5 K helium. The subatmospheric pressure of 16 mbar of the helium bath of the cavities will be achieved by pumping with a set of cold compressors and warm vacuum pumps. While the L700 is already in operating, the 1.8 K system and the helium transfer system are in design phase.

43 PARTICLE ACCELERATORS↗

Proton- and Reductant-Assisted Dioxygen Activation by a Nonheme Iron(II) Complex to Form an Oxoiron(IV) Intermediate

With the aid of HClO{sub 4} as proton and BPh{sub 4}{sup -} as electron source, the Fe complex of a pentadentate pyridyl-appended cyclam ligands can activate dioxygen to yield the corresponding oxoiron(IV) complex (see scheme; TMC-py=1-(2'-pyridylmethyl)-4,8,11-trimethyl-1,4,8,11-tetraazacyclotetradecane; C gray, Fe magneta, N blue, O red). This transformation is proposed to occur via a hydroperoxoiron(III) intermediate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polarimetry at the Superconducting Darmstadt Electron Linac S-DALINAC

A spin polarized electron source will be installed at the S-DALINAC to extend the existing experimental capabilities polarization. In order to manipulate and monitor the beam polarization a Wien filter and different polarimeters will be installed. The already installed Wien filter and 100 keV Mott polarimeter and the planned 5 MeV Mott, 30-130 MeV Moeller and Compton transmission polarimeters are described.

43 PARTICLE ACCELERATORS↗

Physics research and technology developments of electron string ion sources

The most recent experimental information on electron string phenomenon, such as two step transition to electron string state, stability of e-strings in condition of electron energy recuperation, are described. The new technology developments of electron string ion sources (ESIS) include pulse injection of gaseous species in e-string and its efficient conversion to ion beams, slow ion extraction, ion-ion cooling of heavy ions with CH{sub 4} coolant, and a progress in the construction of the new Joint Institute for Nuclear Research ESIS with 6 T solenoid are briefly considered.

43 PARTICLE ACCELERATORS↗

Coupled EM-PIC/Radiation Transport Simulations of HERMES Courtyard Experiments

A suite of coupled computational models for simulating the radiation, plasma, and electromagnetic (EM) environment in the High-Energy Radiation Megavolt Electron Source (HERMES) courtyard has been developed. In principle, this provides a predictive forward-simulation capability based solely on measured upstream anode and cathode current waveforms in the Magnetically Insulated Transmission Line (MITL). First, 2D R-Z ElectroMagnetic Particle-in-Cell (EM-PIC) simulations model the MITL and diode to compute a history of all electrons incident on the converter. Next, radiation transport simulations use these electrons as a source to compute the time-dependent dose rate and volumetric electron production in the courtyard. Finally, the radiation transport output is used as sources for EM-PIC simulations of the courtyard to com- pute electromagnetic responses. This suite has been applied to the November 2016 trials, shots 10268-10313. Modeling and experiment differ in significant ways. This is just the first iteration of a long process to improve the agreement, as outlined in the summary.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diamond X-ray Beam Position Monitors

Modern Synchrotrons are capable of significant per-pulse x-ray flux, and time resolved pulse-probe experiments have become feasible. These experiments provide unique demands on x-ray monitors, as the beam position, flux and arrival time all potentially need to be recorded for each x-ray pulse. Further, monitoring of white x-ray beam position and flux upstream of beamline optics is desirable as a diagnostic of the electron source and insertion device alignment. We report on diamond quadrant monitors which provide beam diagnostics for a variety of applications, for both white and monochromatic beams. These devices have a position resolution of 25 nm for a stable beam, are linear in flux over at least 11 orders of magnitude, and can resolve beam motion shot-by-shot at repetition rates up to 6.5 MHz.

43 PARTICLE ACCELERATORS↗

Note: O-ring stack system for electron gun alignment

We present a reliable method for aligning an electron gun which consists of an electron source and lenses by controlling a stack of rubber O-rings in a vacuum condition. The beam direction angle is precisely tilted along two axes by adjusting the height difference of a stack of O-rings. In addition, the source position is shifted in each of three orthogonal directions. We show that the tilting angle and linear shift along the x and y axes as obtained from ten stacked O-rings are ±2.55° and ±2 mm, respectively. This study can easily be adapted to charged particle gun alignment and adjustments of the flange position in a vacuum, ensuring that its results can be useful with regard to electrical insulation between flanges with slight modifications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photoemission Study of Cs-NF3 Activated GaAs(100) Negative Electron Affinity Photocathodes

GaAs based negative electron affinity photocathodes activated with Cs and NF{sub 3} are used as polarized electron sources for linear accelerators. It is generally believed that the activation layer consists of CsF. The activation layers of Cs-NF{sub 3} on GaAs photocathodes are herein investigated using synchrotron radiation photoelectron spectroscopy (SR-PES). F1s, N1s and other core levels are recorded at photon energies ranging from 70eV to 820eV. Surprisingly, a significant amount of nitrogen is observed in the activation layers. Two distinct species of nitrogen are observed, one of which decreases along with the Fluorine signal as the yield of the photocathode decays with time.

43 PARTICLE ACCELERATORS↗

Implementing a newly proposed Monte Carlo based small field dosimetry formalism for a comprehensive set of diode detectors

Purpose: The goal of this work was to implement a recently proposed small field dosimetry formalism [Alfonso et al., Med. Phys. 35(12), 5179-5186 (2008)] for a comprehensive set of diode detectors and provide the required Monte Carlo generated factors to correct measurement. Methods: Jaw collimated square small field sizes of side 0.5, 0.6, 0.7, 0.8, 0.9, 1.0, and 3.0 cm normalized to a reference field of 5.0 cm x 5.0 cm were used throughout this study. Initial linac modeling was performed with electron source parameters at 6.0, 6.1, and 6.2 MeV with the Gaussian FWHM decreased in steps of 0.010 cm from 0.150 to 0.100 cm. DOSRZnrc was used to develop models of the IBA stereotactic field diode (SFD) as well as the PTW T60008, T60012, T60016, and T60017 field diodes. Simulations were run and isocentric, detector specific, output ratios (OR{sub det}) calculated at depths of 1.5, 5.0, and 10.0 cm. This was performed using the following source parameter subset: 6.1 and 6.2 MeV with a FWHM = 0.100, 0.110, and 0.120 cm. The source parameters were finalized by comparing experimental detector specific output ratios with simulation. Simulations were then run with the active volume and surrounding materials set to water and the replacement correction factors calculated according to the newly proposed formalism. Results: In all cases, the experimental field size widths (at the 50% level) were found to be smaller than the nominal, and therefore, the simulated field sizes were adjusted accordingly. At a FWHM = 0.150 cm simulation produced penumbral widths that were too broad. The fit improved as the FWHM was decreased, yet for all but the smallest field size worsened again at a FWHM = 0.100 cm. The simulated OR{sub det} were found to be greater than, equivalent to and less than experiment for spot size FWHM = 0.100, 0.110, and 0.120 cm, respectively. This is due to the change in source occlusion as a function of FWHM and field size. The corrections required for the 0.5 cm field size were 0.95 ({+-}1.0%) for the SFD, T60012 and T60017 diodes and 0.90 ({+-}1.0%) for the T60008 and T60016 diodes--indicating measured output ratios to be 5% and 10% high, respectively. Our results also revealed the correction factors to be the same within statistical variation at all depths considered. Conclusions: A number of general conclusions are evident: (1) small field OR{sub det} are very sensitive to the simulated source parameters, and therefore, rigorous Monte Carlo linac model commissioning, with respect to measurement, must be pursued prior to use, (2) backscattered dose to the monitor chamber should be included in simulated OR{sub det} calculations, (3) the corrections required for diode detectors are design dependent and therefore detailed detector modeling is required, and (4) the reported detector specific correction factors may be applied to experimental small field OR{sub det} consistent with those presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Study of K2CsSb Photocathode Inside a DC High Voltage Gun

In the past decade, there has been considerable interest in the generation of tens of mA average current in a photoinjector. Until recently, GaAs:Cs cathodes and K{sub 2}CsSb cathodes have been tested successfully in DC and RF injectors respectively for this application. Our goal is to test the K{sub 2}CsSb photocathode inside a DC gun. Since the multialkali cathode is a compound with constant characteristics over its entire thickness, we anticipate that the lifetime issues seen in GaAs:Cs due to surface damage by ion bombardment would be minimized. Hence successful operation of the K{sub 2}CsSb cathode in a DC gun could lead to a relatively robust electron source capable of delivering ampere level currents. In order to test the performance of a K{sub 2}CsSb cathode in a DC gun, we have designed and built a load lock system that allows the fabrication of the cathode at Brookhaven National Lab (BNL) and its testing at Jefferson Lab (JLab). In this paper, we will present the performance of the K{sub 2}CsSb photocathode in the preparation chamber and in the DC gun.

43 PARTICLE ACCELERATORS↗

Modeling of external electric field effect on the carbon and silicon carbide nanotubes

Studying emission characteristics of nanotubes is extremely important for development of electronics. Compared to other electron sources nanotube-based field emitters allow obtaining significant emission currents at relatively low values of the applied field. It is possible due to their unique structure. This article is devoted to theoretical investigation how external electric field effects several samples of open single-wall nanotubes from carbon and silicon carbide. Total energies, dipole moments and band gaps for five types of nanotubes were calculated from the first principles. The numerical experiment results indicate the adequacy of modeling. It was concluded that considered configurations of achiral carbon nanotubes should be semiconductors.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Commissioning of Extended Electron Beam Ion Source at Brookhaven National Laboratory

Here, the Extended Electron Beam Ion Source (EEBIS) has been installed and commissioned at Brookhaven National Laboratory (BNL) hadron accelerator complex in the spring of 2023. EEBIS has replaced its predecessor, RhicEBIS, which provided ions for BNL hadron facilities for over a decade since 2009. The motivations for the source upgrade are to provide higher intensities of the Au 32+ ion beam for the Relativistic Heavy Ion Collider (RHIC) and to provide of an intense source of polarized 3 He 2+ ions for the future Electron Ion Collider (EIC) at BNL. EEBIS is and will continue to be the primary source for a variety of different ion species for the NASA Space Radiation Laboratory (NSRL) at BNL. EEBIS utilizes two identical, two-meter-long unshielded 5T warm bore superconducting solenoids, and it is operated with electron beam current up to 10 A, providing a high-capacity ion traps to fulfill the requirement for high intensity ion beams. The upstream solenoid contains a “short ion trap” with a length of 95 cm, while the “long ion trap” with a length of 178 cm is located inside the downstream solenoid bore. The main features of EEBIS are: * A Gas injection and ionization cell equipped with a Lorenz pulse valve * High-capacity ZAO non-evaporable getter (NEG) custom linear pumping units * In situ apparatus for pumping speed measurements to monitor NEG activation and saturation * “External drift tube” construction with differential pumping stages to provide space for Lorentz pulse valve and 3 He high-field polarization cell * A Ba oxide electron gun cathode. The design of EEBIS as well as the results of its commissioning and first-year operation are presented and discussed.

43 PARTICLE ACCELERATORS↗

Plasma potential and energy spread determination using ion beams extracted from an electron cyclotron resonance source

We have obtained estimates of plasma potentials and energy spreads characterizing an electron cyclotron resonance ion source plasma under different source conditions. Our estimates are obtained from analysis of ion beams extracted from the ion source at 10 kV that are subsequently decelerated into a floating surface scattering chamber where their current intensity incident on a solid sample is measured as function of retardation voltage. The deceleration occurs outside the measurement chamber, permitting beam current measurements in a field-free region. Absence of grids in the deceleration section avoids potential issues of field penetration. The behavior of our deceleration optics was modeled with SIMION. The simulation indicated a linear beam attenuation dependence close to full retardation where the beam current goes to zero. Deviations from this linear dependence observed close to zero beam energy give information on the initial energy spread of the ions extracted from the source. Our decelerated beams measurements are compared with recent in situ probe results and external beams results based on magnetic analysis.

43 PARTICLE ACCELERATORS↗

Status of 200 keV Beam Operations at Nagoya University

We have developed a 200 keV polarized electron source for generating high bunch charge of >3.2 nC within approx1 ns bunch duration for the International Linear Collider (ILC) and >7.7 pC within 30 ps bunch duration for a basic source study of an Energy Recovery Linac (ERL). In order to improve gun operation voltage and an operational lifetime, we have employed new electrode materials of molybdenum and titanium to eliminate field emission dark current, and restructured a beam transport vacuum systems. As a beam generation for the ERL, bunch charge of up to 28 pC was generated by irradiating with sliced laser pulse trains. The details are described in this report.

43 PARTICLE ACCELERATORS↗

Generation of fast photoelectrons in strong-field emission from metal nanoparticles

We investigated the generation and control of fast photoelectrons (PEs) by exposing plasmonic nanoparticles (NPs) to short infrared (IR) laser pulses with peak intensities between 10 12 and 3 × 10 13 W/cm 2 . Our measured and numerically simulated PE momentum distributions demonstrate the extent to which PE yields and cutoff energies are controlled by the NP size, material, and laser peak intensity. For strong-field photoemission from spherical silver, gold, and platinum NPs with diameters between 10 and 100 nm our results confirm and surpass extremely high PEs cutoff energies, up to several hundred times the incident laser-pulse ponderomotive energy, found recently for gold nanospheres [Saydanzad et al., Nanophotonics 12, 1931 (2023)]. As reported previously for dielectric NPs [Rupp et al., J. Mod. Opt. 64, 995 (2017)], at higher intensities the cutoff energies we deduce from measured and simulated PE spectra tend to converge to a metal-independent limit. We expect these characteristics of light-induced electron emission from prototypical plasmonic metallic nanospheres to promote the understanding of the electronic dynamics in more complex plasmonic nanostructures and the design of nanoscale light-controlled plasmonic electron sources for photoelectronic devices of applied interest.

electron source↗

Development of Polarized Photocathodes for the Linear Collider

In prior years a Wisconsin-SLAC collaboration developed polarized photocathodes which were used for the SLAC SLD and fixed target programs. Currently, the R&D program goal is the development of a polarized electron source (PES) which meets the ILC requirements for polarization, charge, lifetime, and pulse structure. There are two parts to this program. One part is the continued improvement of photocathode structures with higher polarization. The second part is the design and development of the laser system used to drive the photocathode. The long pulse train for the ILC introduces new challenges for the PES. More reliable and stable operation of the PES may be achievable if appropriate R&D is carried out for higher voltage operation and for a simpler photocathode load-lock system. The collaboration with SLAC is through the Polarized Photocathode Research Collaboration (PPRC). Senior SLAC personnel include T. Maruyama, J. Clendenin, R. Kirby, and A. Brachmann.

43 PARTICLE ACCELERATORS↗

Status of high current R&D Energy Recovery LINAC at Brookhaven National Laboratory

An ampere class 20 MeV superconducting Energy Recovery Linac (ERL) is under construction at Brookhaven National Laboratory (BNL) for testing of concepts relevant for high-energy coherent electron cooling and electron-ion colliders. One of the goals is to demonstrate an electron beam with high charge per bunch ({approx} 5 nC) and low normalized emittance ({approx} 5 mm-mrad) at an energy of 20 MeV. Flexible lattice of ERL loop provides a test-bed for investigating issues of transverse and longitudinal instabilities, and diagnostics for intense CW e-beam. The superconducting 703 MHz RF photoinjector is considered as an electron source for such a facility. We will start with a straight pass (gun - 5 cell cavity - beam stop) test for the SRF Gun performance studies. Later, we will install and test a novel injection line concept for emittance preservation in a lower energy merger. In this paper we present the status and our plans for construction and commissioning of this facility.

43 PARTICLE ACCELERATORS↗