A Network-Aware Distributed Energy Resource Aggregation Framework for Flexible, Cost-Optimal, and Resilient Operation

To efficiently use the ubiquitous behind-the-meter distributed energy resources (DERs) in distribution systems for providing grid services, this paper presents a hierarchical control framework for DER optimal aggregation and control. We first develop a convex optimization model to evaluate the DER flexibility, and then use a convex model-predictive-control based approach to dispatch those DERs. The hierarchical control framework consists of a utility controller, community aggregators and multiple home energy management systems. The flexibility of the DERs is evaluated by each controller in the hierarchy such that the resultant flexibility is feasible given its operational domain. Based on the determined flexibility, the hierarchical controllers then compute optimal setpoints for the DERs to help the distribution system regulate node voltages and provide other distribution grid services. Numerical simulations performed on a model of a real distribution feeder in Colorado, using actual DER data in a residential community demonstrate that the proposed approach can effectively alleviate voltage issues and support resilient operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Procedure for minimizing the cost per watt of photovoltaic systems

A general analytic procedure is developed that provides a quantitative method for optimizing any element or process in the fabrication of a photovoltaic energy conversion system by minimizing its impact on the cost per watt of the complete system. By determining the effective value of any power loss associated with each element of the system, this procedure furnishes the design specifications that optimize the cost-performance tradeoffs for each element. A general equation is derived that optimizes the properties of any part of the system in terms of appropriate cost and performance functions, although the power-handling components are found to have a different character from the cell and array steps. Another principal result is that a fractional performance loss occurring at any cell- or array-fabrication step produces that same fractional increase in the cost per watt of the complete array. It also follows that no element or process step can be optimized correctly by considering only its own cost and performance

Redfield, D.↗

Valuation of Distributed Wind in an Isolated System

Remote communities are increasingly adopting renewable energy, such as wind, as they transition away from diesel energy generation. It is important to understand the benefits and costs of wind energy to isolated systems so that decision-makers can optimize their choices in these communities. There are few examples of valuation of wind energy as a distributed resource and numerous differences in valuation approaches, especially in the inclusion of environmental and economic impacts. We apply a distributed wind valuation framework to calculate the benefits and costs of wind in St. Mary’s, Alaska, to the local electric cooperative and to society, finding that the project does not have a favorable benefit-to-cost ratio unless societal benefits are included, in which case the benefit-to-cost ratio is nearly double. Government funding is important to reducing the initial capital expenditures of this wind project and will likely be the case for projects with similar characteristics. Additional fuel savings benefits are potentially possible for this project through technological additions such as energy storage and advanced controls.

17 WIND ENERGY↗

Utilization of waste heat from a commercial GT for freshwater production, cooling and additional power: Exergoeconomic analysis and optimization

In this work, a multigeneration system is proposed for power, cooling and freshwater production. The waste heat from a SIEMENS SGT6-2000E GT is utilized to drive a supercritical CO 2 recompression Brayton cycle (SCRBC) and multi-effect desalination (MED) with thermal vapor compressor (TVC), while the waste heat from the pre-cooler of the SCRBC is utilized to drive an absorption cooling cycle. Detailed thermodynamic, exergy and exergoeconomic analyses are performed for the proposed multigeneration system using Engineering Equation Solver (EES). A sensitivity study is also performed to study the effects of the main operational parameters on the proposed system performance. Finally, multi-objective optimization using a genetic algorithm approach in EES is carried out to reach the optimal design. The proposed system can consume 34.2% less energy input and reduce CO 2 emission by 39.3% compared to the stand-alone systems for power, cooling and freshwater production. The results show that the energy utilization factor and exergy efficiency of the proposed system are improved by 33.6% and 14.3%, respectively, while the total unit product cost is reduced by 11.3% compared to the stand-alone GT cycle. Further, from exergoeconomic optimization, the proposed system can produce 132.4 MW of power, 7.09 MW of cooling and 650 kg/s of freshwater at energy utilization factor of 57.5%, exergy efficiency of 39.7% and total unit product cost of 16.3 $/GJ.

42 ENGINEERING↗

The Best of Both Worlds: Combined Thermal and Battery Storage for Widespread Building Decarbonization

To meet 2050 decarbonization targets, widespread building electrification is a critical complement to clean power generation. Behind-the-meter storage (BTMS) (e.g., battery electric energy storage [EES] and thermal energy storage [TES]) integrated with buildings or building end uses to store and supply energy at optimal times can minimize burdens associated with operation, planning, and upgrades to the electrical grid sometimes triggered by building electrification. Such BTMS systems can serve the dual purpose of providing enhanced resilience at the building and grid level, and support the deployment of renewable generation needed for wide-scale decarbonization. While TES can cost-effectively shed and shift thermal loads, it cannot generally backup or shift non-thermal building end uses. EES, by contrast, is more expensive, but applicable to all end uses (i.e., thermal and electrical loads). Combined together, these storage systems can be traded off against one another to perform optimally in meeting demand flexibility, decarbonization goals, and energy resilience of the buildings at a lower total system cost. This paper proposes a framework to define BTMS benefits, provides four illustrative electrification scenarios using TES and EES, and discusses the combined TES/EES benefits with building energy modeling results. The paper also highlights potential barriers to adoption of BTMS and a path forward.

buildings↗

Optimal Force Control of Vibro-Impact Systems for Autonomous Drilling Applications

The need to maintain optimal energy efficiency is critical during the drilling operations performed on future and current planetary rover missions (see figure). Specifically, this innovation seeks to solve the following problem. Given a spring-loaded percussive drill driven by a voice-coil motor, one needs to determine the optimal input voltage waveform (periodic function) and the optimal hammering period that minimizes the dissipated energy, while ensuring that the hammer-to-rock impacts are made with sufficient (user-defined) impact velocity (or impact energy). To solve this problem, it was first observed that when voice-coil-actuated percussive drills are driven at high power, it is of paramount importance to ensure that the electrical current of the device remains in phase with the velocity of the hammer. Otherwise, negative work is performed and the drill experiences a loss of performance (i.e., reduced impact energy) and an increase in Joule heating (i.e., reduction in energy efficiency). This observation has motivated many drilling products to incorporate the standard bang-bang control approach for driving their percussive drills. However, the bang-bang control approach is significantly less efficient than the optimal energy-efficient control approach solved herein. To obtain this solution, the standard tools of classical optimal control theory were applied. It is worth noting that these tools inherently require the solution of a two-point boundary value problem (TPBVP), i.e., a system of differential equations where half the equations have unknown boundary conditions. Typically, the TPBVP is impossible to solve analytically for high-dimensional dynamic systems. However, for the case of the spring-loaded vibro-impactor, this approach yields the exact optimal control solution as the sum of four analytic functions whose coefficients are determined using a simple, easy-to-implement algorithm. Once the optimal control waveform is determined, it can be used optimally in the context of both open-loop and closed-loop control modes (using standard realtime control hardware).

Aldrich, Jack B.↗

High-Temperature Aquifer Thermal Energy Storage (HT-ATES) Projects in Germany and the Netherlands—Review and Lessons Learned

Aquifer thermal energy storage (ATES) is a concept that can help to address heating and cooling needs through the use of the subsurface as a seasonal thermal energy storage (STES) system. Over 2800 ATES systems have been deployed with storage temperatures typically below 25 °C and only a few with higher temperatures (>40 °C), which would increase the energy density and utility of the stored thermal fluids. Until now, only a few high-temperature aquifer thermal energy storage (HT-ATES) projects have been initiated and are still in operation. These HT-ATES projects have encountered a range of technical and non-technical challenges. This study reviews ten such projects: four in Germany and six in the Netherlands. The non-technical issues include public acceptance, a lack of regulatory framework for these systems, managing overlapping uses of the subsurface, managing changes with the providers and off-takers of thermal energy, and obtaining financing to implement these projects. Common technical issues include geological factors such as incomplete characterization of the subsurface and reservoir heterogeneity; geochemical issues such as mineral scaling, corrosion, and biofouling; lower than expected thermal recovery; and issues with system design and reliability. This review highlights benefits and challenges faced by HT-ATES projects with the goal to use the lessons learned to improve the siting, design, development, and operation of such systems. Recommendations include improved initial subsurface site characterization, use of coupled process models to optimize system design and predict system performance, cascaded uses of stored thermal energy to better utilize the stored heat, monitoring networks to provide feedback on system performance, and expanded system scale to allow for continued operation even when maintenance of some system components is required. Techno-economic modeling and risk analysis could be used to optimize such HT-ATES project design and identify key factors that will affect sustained economic viability. In addition, design flexibility is important for these systems to allow for changing conditions regarding the supply and demand of thermal energy. Adopting these findings should improve the performance and reduce the risks for future HT-ATES projects worldwide.

15 - GEOTHERMAL ENERGY↗

Coupling Subsurface and Above-Surface Models for Optimizing the Design of Borefields and District Heating and Cooling Systems

Accurate dynamic energy simulation is important for the design and sizing of district heating and cooling systems with geothermal heat exchange for seasonal energy storage. Current modeling approaches in building and district energy simulation tools typically consider heat conduction through the ground between boreholes without flowing groundwater. While detailed simulation tools for subsurface heat and mass transfer exist, these fall short in simulating above-surface energy systems. To support the design and operation of such systems, the study developed a coupled model including a software package for building and district energy simulation, and software for detailed heat and mass transfer in the subsurface. For the first, it uses the open-source Modelica Buildings Library, which includes dynamic simulation models for building and district energy and control systems. For the heat and mass transfer in the soil, it uses the TOUGH simulator. The TOUGH family of codes can model heat and multi-phase, multi-component mass transport for a variety of fluid systems, as well as chemical reactions, in fractured porous media. The study validated the coupled modeling approach by comparing the simulation results with one from the g-function based ground response model. It then looked into effects when the water table and the regional groundwater flow are considered in the ground, from the perspective of heat exchange between borehole and ground, and the electrical consumption of the district heating and cooling systems. To access the simulation models, please find the links in the submission: -- For coupled approach validation: see model Buildings.Fluid.Geothermal.Borefields.Examples.BorefieldsWithTough and Buildings.Examples.DistrictReservoirNetworks.Examples.Reservoir3Variable_TOUGH from the "Modelica Building Library" resource, branch issue1495_tough_interface, commit a2667c0. -- For the study of the effect of water table: see model Buildings.Examples.DistrictReservoirNetworks.Examples.Reservoir3Variable_TOUGH from he "Modelica Building Library" resource, branch issue1495_tough_interface_moreIO, commit 760de49. -- For the study of the effect of regional groundwater flow: see Buildings.Examples.DistrictReservoirNetworks.Examples.Reservoir3Variable_TOUGH from he "Modelica Building Library" resource, branch issue1495_tough_interface_moreIO_3D, commit c2a2d2a. The coupling interface script "GrounResponse.py" can be found from the above links in the folder Buildings/Resources/Python-Sources. Also, the needed files for TOUGH simulation are in the folder Buildings/Resources/Python-Sources/ToughFiles that can be accessed through the above links. A brief description of these files is given below; detailed specifications for the first three files may be found in the TOUGH3 Users Guide (Jung et al., 2018) https://tough.lbl.gov/documentation/tough-manuals/. (1) INCON - initial conditions for each grid block (2) INFILE - main input file with material properties and control parameters (3) MESH - description of the computational grid (4) readsave - Modelica/TOUGH interface program: read the final output of TOUGH simulation after TOUGH time step and prepare for transfer to Modelica for next Modelica time step (5) readsave.inp - input parameters for program readsave (6) writeincon - Modelica/TOUGH interface program: write the output of Modelica after Modelica time step and prepare for transfer to TOUGH as initial conditions for the next TOUGH step (7) writeincon.inp - input parameters for program writeincon

15 GEOTHERMAL ENERGY↗

Modelling and Optimizing CSP-PV Hybrid Systems Using the Hybrid Optimization and Performance Platform (HOPP)

The hybridization of concentrating solar power (CSP) with thermal energy storage (TES), photovoltaics (PV), and electrochemical battery energy storage systems (BESS) has the potential to provide continuous, high-capacity-factor energy production at a lower cost than a PV-BESS or CSP with TES alone. Because of the system complexity of CSP technology, it is challenging to evaluate the technological and financial performance of a CSP-PV hybrid system without detailed modeling of annual operations. To address this challenge, we have developed a modeling framework for evaluating the performance and financial viability of CSP systems hybridized with PV and BESS technologies. This modeling effort incorporates CSP tower and trough configurations into an existing modeling tool recently developed by NREL, the Hybrid Optimization and Performance Platform (HOPP). This paper provides a brief overview of our methodology, as well as an example case study. CSP with TES hybridized with PV provides the best benefit-to-cost ratio compared to the other simulated technology combinations. However, for the conditions considered, this configuration only increases the benefit-to-cost ratio by about 1% compared to the CSP with TES configuration. The PV-BESS system provides the lowest benefit-to-cost ratio compared to the other configurations explored because of the relatively low capacity credit received by the system.

Hamilton, William (ORCID:0000000244654239)↗

Dynamic Modeling of a Kaplan Hydroturbine Using Optimal Parametric Tuning and Real Plant Operational Data

To address grid variability caused by renewable energy integration and to maintain grid reliability and resilience, hydropower must quickly adjust its power generation over short time periods. This changing energy generation landscape requires advance technology integration and adaptive parameter optimization for hydropower systems via digital twin effort. However, this is difficult owing to the lack of characterization and modeling for the nonlinear nature of hydroturbines. To solve this issue, this paper first formulates a six-coefficient Kaplan hydroturbine model and then proposes a parametric optimization tuning framework based on the Nelder–Mead algorithm for adaptive dynamic learning of the six-coefficients so as to build models that describe the turbine. To assess the performance of the proposed optimal parametric tuning technique, operational data from a real-world Kaplan hydroturbine unit are collected and used to model the relationship between the gate opening and the generated power production. The findings show that the proposed technique can effectively and adaptively learn the unknown dynamics of the Kaplan hydroturbine while optimally tune the unknown coefficients to match the generated power output from the real hydroturbine unit with an inaccuracy of less than 5%. The method can be used to provides optimal tuning of parameters critical for controller design, operational optimization and daily maintenance for hydroturbines in general.

13 HYDRO ENERGY↗

Eco-driving Profile Optimization by Dynamic Programming for Battery Electric Vehicles

Although full automation has not yet been achieved, automated vehicles are a valid research area. Not only would automated vehicles provide ultimate driver convenience, but they would maximize energy efficiency by eliminating undesired human driving behaviors and optimally controlling the powertrain. From the perspective of control related to energy saving, speed profile optimization is important for improving system efficiency and satisfying passenger demands. This study employs Dynamic Programming (DP) to solve the constrained optimal problem for travel time, distance, and speed limit by exploring all possible control options. The solutions obtained by DP demonstrate consistent control patterns combining four control modes-acceleration, cruising, coasting, and braking, with cruising or coasting being selective depending on the boundary conditions. Further, this study introduces DP-based simulation results and attempts to provide comprehensive interpretations of the optimal policy by analyzing the essential factors that affect the control problem, including boundary conditions, road load, and powertrain characteristics. Based on these interpretations, the control concepts can be explained as the optimal policy selecting the best control option based on system efficiency and boundary conditions. The results of DP are compared with a human-like driver model to show that the optimal speed profiles can effectively reduce energy consumption.

Autonomous vehicles↗

A Case Study on Condenser Water Supply Temperature Optimization with a District Cooling Plant

District cooling (DC) continues to proliferate due to increasing global cooling demands and economies of scale benefits; however, most district-scale modeling has focused on heating, and to the best of our knowledge, researchers have yet to model cooling plants featuring waterside economizers in DC settings. With the popular Modelica Buildings library expanding its capabilities to district scale, this study is one of the first to demonstrate how the open-source models can be used for detailed energy and control analysis of a DC plant. For a real-world case study, we developed and calibrated high-fidelity models for a DC system central plant at a college campus in Colorado, USA, and we optimized the condenser water supply temperature (CWST) setpoint for a DC plant across multiple time horizons using the Optimization library in Dymola. Results indicate that annual CWST optimization saves 4.7% annual plant energy, with less than 1% of additional energy savings gained through daily optimization. This confirms previous studies' findings that high frequency CWST optimizations are not necessary for the studied system.

chiller plant↗

Analysis of Distributed Energy Storage as a Core Grid Infrastructure via Production Cost Modeling

Energy storage plays a pivotal role in enabling power system operation with more flexibility and resilience. Unlike current practice that considers energy storages as attached ancillary devices, this paper focuses on storages as a core infrastructure by looking at their spatial distribution in the system. A sensitivity analysis based on production cost modeling is conducted to demonstrate the benefits of distributed energy storages. First, the modeling of energy storages in production cost modeling is presented. Second, potential optimal locations of distributed energy storages in a power system are discussed. Finally, multiple scenarios with various numbers and locations of additional distributed energy storages in the WECC 2030 model are created. The production cost modeling results of these scenarios show that distributed energy storages have higher utilization compared to the centralized ES units and therefore provide significantly more benefits in terms of reduction in generation cost, emission cost, and volatility of location marginal prices. A saturation effect is observed suggesting the selection of optimal locations will further improve the benefits.

Nguyen, Quan H.↗

Primary Heat Transport System Design Considerations for Xcimer Energy’s Athena Fusion Pilot Plant

Fusion energy promises a reliable, carbon-free source of power; however, significant challenges remain before it can be deployed as an economical energy source. In addition to achieving fusion conditions, power plants must operate under extreme temperatures, radiation, and mechanical loads while maintaining high efficiency and availability. These requirements place strong demands on engineering design and plant operation. This work focuses on the engineering challenges associated with balance of plant analysis for inertial fusion energy systems. In particular, this paper examines the design considerations for primary heat transfer systems in fusion pilot plants employing molten fluoride salt coolants, with particular emphasis on system layout optimization and the balance between competing design objectives using the Xcimer Energy Athena inertial pilot plant design as a case study. Through systematic analysis of candidate system configurations and parametric sensitivity studies, we identify key engineering trade-offs governing salt inventory, pumping power requirements, and operational flexibility. The analysis employs system-level modeling tools to explore the design space and establish relationships between geometric parameters and system performance metrics.

Greenwood, Scott [ORNL] (ORCID:0000000333480736)↗

Optimizing Grid Regulation With Gravity Storage Systems: A Comparative Analysis With Different Motor Inertias: Preprint

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between the energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid generation-demand imbalances is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS systems provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 seconds from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS with a high-inertia motor may be able operate over a broader range of frequency variations whereas a low-inertia system may be limited by thermal constraints of the motor.

frequency regulation↗

Bench-scale Development of a Transformational Graphene Oxide-based Membrane Process for Post-combustion CO 2 Capture

Graphene-based materials, such as graphene and graphene oxide (GO), have been considered as next-generation membrane materials. GTI Energy and The State University of New York at Buffalo (UB) have been developing a transformational GO-based membrane process (designated as GO2) that integrates a high CO 2 /N 2 selectivity membrane (GO-1) and a high CO 2 flux membrane (GO-2) for post-combustion CO 2 capture. An innovative membrane structure, consisting of GO nanochannels intercalated by single-walled carbon nanotube (SWCNT), was developed. The membrane prepared on hollow fiber substrate showed CO 2 permeance as high as 1,300 GPU with CO 2 /N 2 selectivity >200. The membranes were successfully scaled up to effective area of 50-100 cm 2 . The 50-100 cm 2 membranes showed CO 2 /N 2 selectivity ≥200 and CO 2 permeance ≥1,000 GPU for the GO-1 type, and CO 2 /N 2 selectivity ≥20 and CO 2 permeance ≥2,500 GPU for the GO-2 type. The CO 2 capture performance of the GO-based membranes was tested using a simulated flue gas. The testing results indicate that the GO-based membranes are stable in the presence of flue gas contaminants. The GO-based membranes were then further scaled up to a surface area of 1,000 cm 2 . Good stability was achieved during an integrated testing with GO-1 and GO-2 membranes using simulated flue gas. A bench-scale system was designed, constructed, and tested at the National Carbon Capture Center (NCCC). Good stability was achieved during testing of a single-stage process with >10 shutdowns/startups at NCCC. During the integrated testing, the membranes showed good stability at 50°C and 57°C. 70-90% CO 2 removal efficiencies and ≥95% CO 2 purity were validated during the steady state operation at NCCC. Techno-economic analysis indicates the GO2 membrane-based process technology provides a reduction in both the levelized cost of electricity (LCOE) and cost of capture when compared to the reference B12B case presented in the Cost and Performance Baseline for Fossil Energy Plants Volume 1: Bituminous Coal and Natural Gas to Electricity study prepared by the National Energy Technology Laboratory (NETL), before considering any system optimization or improvement opportunities. The benefits are primarily driven by a reduction in the equipment costs of the CO 2 capture process vs. the solvent-based reference process in NETL Case B12B as well as a decrease in the base plant size.

20 FOSSIL-FUELED POWER PLANTS↗

The influence of fire aerosols on surface climate and gross primary production in the Energy Exascale Earth System Model (E3SM)

Fire-emitted aerosols play an important role in influencing Earth’s climate, directly by scattering and absorbing radiation and indirectly by influencing cloud microphysics. The quantification of fire-aerosol interactions, however, remains challenging and subject to uncertainties in emissions, plume parameterizations, and aerosol properties. Here we optimized fire-associated aerosol emissions in the Energy Exascale Earth System Model (E3SM) using the Global Fire Emissions Database (GFED) and AERONET aerosol optical depth (AOD) observations during 1997-2016. Furthermore, we distributed fire emissions vertically using smoke plume heights from Multi-angle Imaging SpectroRadiometer (MISR) satellite observations. From the optimization, we estimate that global fires emit 45.5 Tg y -1 of primary particulate organic matter and 3.9 Tg y -1 of black carbon. We then performed two climate simulations with and without the optimized fire emissions. We find that fire aerosols significantly increase global AOD by 14 ± 7% and contribute to a reduction in net shortwave radiation at the surface (-2.3 ± 0.5 W m -2 ). Together, fire-induced direct and indirect aerosol effects cause annual mean global land surface air temperature to decrease by 0.17 ± 0.15°C, relative humidity to increase by 0.4 ± 0.3%, and diffuse light fraction to increase by 0.5 ± 0.3%. In response, GPP declines by 2.8 Pg C y -1 , as a result of large positive drivers (decreases in temperature and increases in humidity and diffuse light) nearly cancelling out large negative drivers (decreases shortwave radiation and soil moisture). Our analysis highlights the importance of fire aerosols in modifying surface climate and photosynthesis across the tropics.

54 ENVIRONMENTAL SCIENCES↗