Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Assessment of Tritium Activities in Bailed versus Pumped Samples from Wells at the Nevada National Security Site

The Underground Test Area (UGTA) Activity uses a variety of methods to collect groundwater samples to identify radionuclide migration from underground nuclear tests. These include depth-discrete bailing, pumping with low-volume rod pumps, and pumping with electrical submersible pumps. The Nevada National Security Site (NNSS) Integrated Groundwater Sampling Plan specifies that when sampling with a pump, a minimum of three effective well volumes are withdrawn and then samples are collected after water-quality parameters have stabilized. In locations where pumping is not feasible, depth-discrete bailing is used and purging prior to sampling is usually not required. A recent study evaluated three sampling technologies and recommended that historical tritium results be evaluated where both pumped and bailed samples are available to identify preferred sampling protocols for the collection of tritium samples. The tritium ( 3 H) activities were obtained from the UGTA chemistry data base. Wells were identified with known 3 H activities above method detection limits, and then evaluated if both bailed and pumped samples had been collected. Twenty two wells and piezometers with bailed samples, pumped samples, and 3 H activities above background were identified for further consideration. The conclusions from this analysis are: Bailed samples collected for 3 H analysis near the water surface in a well are lower in 3 H activity than bailed samples from within screened intervals and pumped samples. Depth-discrete bailed samples from within the screened intervals are generally in good agreement with pumped samples from developed wells and piezometers. Depth-discrete bailed samples from undeveloped wells and piezometers are in good agreement with the first pumped samples. However, the next pumped samples increased in 3 H activity, resulting in a greater percent difference between the undeveloped bailed samples and later pumped samples. Continuous pumping over extended periods removing large purge volumes from wells can perturbate the surrounding groundwater system for long periods of time. These perturbations can cause large changes in 3 H activities in the aquifer near the well because of the mixing of groundwater with variable 3 H activities. Recommendations include: Bailed samples for 3 H should not be collected near the water surface in the well. Bailed samples should be collected from within the well screen. Logs of temperature, chemistry, and thermal flow should be evaluated to identify optimal depths within the well screen to collect depth-discrete bailer samples. Purging of large volumes of water from the well over extended periods of time should be avoided when collecting 3 H samples. Sufficient time should be allowed after pumping large volumes of water from the well (e.g., after well development) for the surrounding aquifer and 3 H activities to return to ambient conditions

54 ENVIRONMENTAL SCIENCES↗

An Evaluation of the Network Simulators in Large-Scale Distributed Simulations

This is a survey paper about the state-of-the-art in large-scale network simulation. Networks for the smart grids are characterized by millions of sensor nodes exchanging information about the status of the grid. This information exchange must be realized reliably and efficiently due to the mission critical nature of the power grid. Hence, the applications and the network protocols developed for the smart grid need go through rigorous testing and analysis before deployment. Developers usually do not have access to such a large-scale network that can be used as a controlled test-bed; therefore, network simulation becomes an essential tool for testing. Network simulation is a well studied problem in the literature and there are various widely used network simulators. These simulators can be adopted for testing applications and protocols of the smart grid. Due to the scale of these networks, parallel/distributed simulations need to be conducted. Even though most network simulators support distributed simulations, generating a large-scale network model to simulate can still be a cumbersome task. In this survey, we describe a selection of commonly used network simulators and evaluate them with respect to the following features that can aid users in distributed simulations of large-scale networks: transparency of setting up distributed simulation, automated topology generation, information hiding, lightweight routing protocols, network error simulation, evaluation of the network model during simulation and trace analysis tools. As a complementary result, we identify two issues with network simulators that can be addressed with runtime steering methods.

99 GENERAL AND MISCELLANEOUS↗

A prototype fan-beam optical CT scanner for 3D dosimetry

Purpose: The objective of this work is to introduce a prototype fan-beam optical computed tomography scanner for three-dimensional (3D) radiation dosimetry. Methods: Two techniques of fan-beam creation were evaluated: a helium-neon laser (HeNe, {lambda} = 543 nm) with line-generating lens, and a laser diode module (LDM, {lambda} = 635 nm) with line-creating head module. Two physical collimator designs were assessed: a single-slot collimator and a multihole collimator. Optimal collimator depth was determined by observing the signal of a single photodiode with varying collimator depths. A method of extending the dynamic range of the system is presented. Two sample types were used for evaluations: nondosimetric absorbent solutions and irradiated polymer gel dosimeters, each housed in 1 liter cylindrical plastic flasks. Imaging protocol investigations were performed to address ring artefacts and image noise. Two image artefact removal techniques were performed in sinogram space. Collimator efficacy was evaluated by imaging highly opaque samples of scatter-based and absorption-based solutions. A noise-based flask registration technique was developed. Two protocols for gel manufacture were examined. Results: The LDM proved advantageous over the HeNe laser due to its reduced noise. Also, the LDM uses a wavelength more suitable for the PRESAGE{sup TM} dosimeter. Collimator depth of 1.5 cm was found to be an optimal balance between scatter rejection, signal strength, and manufacture ease. The multihole collimator is capable of maintaining accurate scatter-rejection to high levels of opacity with scatter-based solutions (T < 0.015%). Imaging protocol investigations support the need for preirradiation and postirradiation scanning to reduce reflection-based ring artefacts and to accommodate flask imperfections and gel inhomogeneities. Artefact removal techniques in sinogram space eliminate streaking artefacts and reduce ring artefacts of up to {approx}40% in magnitude. The flask registration technique was shown to achieve submillimetre and subdegree placement accuracy. Dosimetry protocol investigations emphasize the need to allow gel dosimeters to cool gradually and to be scanned while at room temperature. Preliminary tests show that considerable noise reduction can be achieved with sinogram filtering and by binning image pixels into more clinically relevant grid sizes. Conclusions: This paper describes a new optical CT scanner for 3D radiation dosimetry. Tests demonstrate that it is capable of imaging both absorption-based and scatter-based samples of high opacities. Imaging protocol and gel dosimeter manufacture techniques have been adapted to produce optimal reconstruction results. These optimal results will require suitable filtering and binning techniques for noise reduction purposes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fracture Toughness Evaluation for Spent Nuclear Fuel Clad Systems Using Spiral Notch Torsion Fracture Toughness Test

Many radioactive materials within the nuclear fuel cycle present a significant hazard. Such materials include spent nuclear fuel, high-level waste, legacy waste and other nuclear materials. These materials are often held in long-term storage as an interim stage within their lifecycle, including reuse or disposal. Safety and security of spent nuclear fuel (SNF) interim storage installations and follow-on SNF transportations to its final repository sites are very important, due to a great concentration of fission products, actinides and activation products. Fracture mechanics approach in applying to SNF system reliability investigation, especially for the high burn up (HBU) SNF, during SNF long term dry storage or SNF transportation is necessary due to the inherited flaws and inhomogeneity structures existed in a SNF system from the reactor operation. For instance, such as hydride and oxide formation, surface flaw induced by SNF assembly contact interactions, or internal flaws induced by pellet-clad mechanical interaction (PCMI). However, none of the existing fracture toughness data deal with fuel cladding specific geometry or SNF material conditions, such as cladding structure with the segment fuel pellets configuration and the PCMI mechanism. Consequently, the application of existing fracture toughness data to SNF system reliability investigation can be error prone; thus, the development of an industry-wide consensus fracture mechanics approach is needed. The objective of this research is to develop an in-situ fracture mechanics testing protocol, including the associated analytical procedure, that is suitable for evaluating the SNF fracture toughness. Fracture toughness data was obtained under quasi-static fracture loading using Oak Ridge National Laboratory (ORNL) developed Spiral Notch Torsion Test (SNTT) technology carried out on a biaxial tension/torsion tester. These data will be used to support SNF reliability investigation during long-tern SNF dry storage stage or in the follow-on SNF system transport to the final repository sites. SNTT has been a recent breakthrough in measuring fracture toughness for different materials, including metals, ceramics, concrete and polymers composites. Due to its high geometry constraint and unique loading condition, SNTT can be used to measure the fracture toughness with smaller specimens without concern of size effects. The application of SNTT to brittle materials has been proved to be successful. The micro-cracks induced by original notches in brittle materials could ensure crack growth in SNTT samples. Therefore, no fatigue pre cracks are needed for brittle materials specimens. The application of SNTT to the ductile material to generate valid toughness data will require a test sample with sufficient pre-crack length to increase the sample localized constraint at crack front. Fatigue pre-crack growth techniques with the associated compliance function estimated was developed for estimating the crack penetration depth to monitor the fatigue crack growth evolution. In order to extend SNTT approach to a thin shell cladding structure material, a new testing protocol and the associated analytical procedure for estimating the SNF fracture toughness was developed. The detailed SNTT approach and its estimated fracture toughness for the Zr-4 cladding structure with segment alumina inserts are presented in this report. The SNTT test results indicate that SNTT method is a reliable test approach with good repeatability in applying to Zr-4 cladding material. For the medium and the short crack length, the estimate J Q upon fracture for the baseline Zr-4 cladding is at 285.7 lb/in with 2-sigma uncertainty of 18.59 lb/in., and the associated K Q is at 61.4 Ksi√in. For a long crack length, the crack initialization orientation is apparently deviated from the principle tensile stress contour – 45° spiral crack front (i.e., Mode I + Mode III failure mechanism); and the estimated J Q is at 108 lb/in., the associated K Q is at 37.7 Ksi√in. The estimate Mode I J Q (along the 45° pitch principle tensile stress contour) is at 200 lb/in.; which indicate a significant reduction in the fracture toughness in a tubing structure under mixed mode loading condition, Mode I + Mode III, compared to that of Mode I (tensile stress dominated) alone.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of imaging quality for flat-panel detector based low dose C-arm CT system

The image quality associated with the extent of the angle of gantry rotation, the number of projection views, and the dose of X-ray radiation was investigated in flat-panel detector (FPD) based C-arm cone-beam computed tomography (CBCT) system for medical applications. A prototype CBCT system for the projection acquisition used the X-ray tube (A-132, Varian inc.) having rhenium-tungsten molybdenum target and flat panel a-Si X-ray detector (PaxScan 4030CB, Varian inc.) having a 397 x 298 mm active area with 388 μm pixel pitch and 1024 x 768 pixels in 2 by 2 binning mode. The performance comparison of X-ray imaging quality was carried out using the Feldkamp, Davis, and Kress (FDK) reconstruction algorithm between different conditions of projection acquisition. In this work, head-and-dental (75 kVp/20 mA) and chest (90 kVp/25 mA) phantoms were used to evaluate the image quality. The 361 (30 fps x 12 s) projection data during 360 deg. gantry rotation with 1 deg. interval for the 3D reconstruction were acquired. Parke weighting function were applied to handle redundant data and improve the reconstructed image quality in a mobile C-arm system with limited rotation angles. The reconstructed 3D images were investigated for comparison of qualitative image quality in terms of scan protocols (projection views, rotation angles and exposure dose). Furthermore, the performance evaluation in image quality will be investigated regarding X-ray dose and limited projection data for a FPD based mobile C-arm CBCT system. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo calculations of electron beam quality conversion factors for several ion chamber types

Purpose: To provide a comprehensive investigation of electron beam reference dosimetry using Monte Carlo simulations of the response of 10 plane-parallel and 18 cylindrical ion chamber types. Specific emphasis is placed on the determination of the optimal shift of the chambers’ effective point of measurement (EPOM) and beam quality conversion factors. Methods: The EGSnrc system is used for calculations of the absorbed dose to gas in ion chamber models and the absorbed dose to water as a function of depth in a water phantom on which cobalt-60 and several electron beam source models are incident. The optimal EPOM shifts of the ion chambers are determined by comparing calculations of R{sub 50} converted from I{sub 50} (calculated using ion chamber simulations in phantom) to R{sub 50} calculated using simulations of the absorbed dose to water vs depth in water. Beam quality conversion factors are determined as the calculated ratio of the absorbed dose to water to the absorbed dose to air in the ion chamber at the reference depth in a cobalt-60 beam to that in electron beams. Results: For most plane-parallel chambers, the optimal EPOM shift is inside of the active cavity but different from the shift determined with water-equivalent scaling of the front window of the chamber. These optimal shifts for plane-parallel chambers also reduce the scatter of beam quality conversion factors, k{sub Q}, as a function of R{sub 50}. The optimal shift of cylindrical chambers is found to be less than the 0.5 r{sub cav} recommended by current dosimetry protocols. In most cases, the values of the optimal shift are close to 0.3 r{sub cav}. Values of k{sub ecal} are calculated and compared to those from the TG-51 protocol and differences are explained using accurate individual correction factors for a subset of ion chambers investigated. High-precision fits to beam quality conversion factors normalized to unity in a beam with R{sub 50} = 7.5 cm (k{sub Q}{sup ′}) are provided. These factors avoid the use of gradient correction factors as used in the TG-51 protocol although a chamber dependent optimal shift in the EPOM is required when using plane-parallel chambers while no shift is needed with cylindrical chambers. The sensitivity of these results to parameters used to model the ion chambers is discussed and the uncertainty related to the practical use of these results is evaluated. Conclusions: These results will prove useful as electron beam reference dosimetry protocols are being updated. The analysis of this work indicates that cylindrical ion chambers may be appropriate for use in low-energy electron beams but measurements are required to characterize their use in these beams.

07 ISOTOPE AND RADIATION SOURCES↗

Development of a Reference Design for a Cyber-Physical System

The purpose of this thesis is to develop a reference design to assist in the selection of security practices in power electronics design. A prototype will be developed from this reference design for evaluation. This evaluation will include a brief cost/benefit analysis to gauge the efficacy of implementing each layer of security throughout the power electronics design process. This thesis will also describe the obstacles and effectiveness of integrating a Trusted Platform Module (TPM) into a cyber-hardened grid-connected device. The TPM device is a secured crypto processor that assists in generating, storing, and restricting the use of cryptographic keys. The emphasis of this research is to establish integrity, authenticity, and confidentiality within a system by providing a baseline of security concerns for segments of the system. This research considers communication, control, and hardware level securities. The scope of this thesis will review the necessary security methods as well as consider the effects these methods have on the embedded system, to assess the desired security to responsiveness trade off. Applying this approach to a design process will alleviate various unknowns of appending security to a power electronics design. This thesis describes the specific vulnerabilities introduced within this grid-edge environment, and how the liabilities within the system can be mitigated. Initially, common security techniques will be considered to establish a guideline to benchmark performance and resource costs of the system. The foundation will be a non-hardened power electronic system platform with industry standard communication protocols. Several security techniques and attack vectors will then be evaluated to contribute to the base level platform. Other fail-safe features take place to gauge progress of the selected approach, non-inclusive to the TPM. Collectively, this investigation will determine a valid experiment by appraising and categorizing resource allocation, performance overhead, and monetary cost analysis results into a reference design. The prototype will then demonstrate methods to relieve common threats that are purposefully implemented into the design.

Blair, Nicholas Paul↗

Delay and Disruption Tolerant Networking MACHETE Model

To verify satisfaction of communication requirements imposed by unique missions, as early as 2000, the Communications Networking Group at the Jet Propulsion Laboratory (JPL) saw the need for an environment to support interplanetary communication protocol design, validation, and characterization. JPL's Multi-mission Advanced Communications Hybrid Environment for Test and Evaluation (MACHETE), described in Simulator of Space Communication Networks (NPO-41373) NASA Tech Briefs, Vol. 29, No. 8 (August 2005), p. 44, combines various commercial, non-commercial, and in-house custom tools for simulation and performance analysis of space networks. The MACHETE environment supports orbital analysis, link budget analysis, communications network simulations, and hardware-in-the-loop testing. As NASA is expanding its Space Communications and Navigation (SCaN) capabilities to support planned and future missions, building infrastructure to maintain services and developing enabling technologies, an important and broader role is seen for MACHETE in design-phase evaluation of future SCaN architectures. To support evaluation of the developing Delay Tolerant Networking (DTN) field and its applicability for space networks, JPL developed MACHETE models for DTN Bundle Protocol (BP) and Licklider/Long-haul Transmission Protocol (LTP). DTN is an Internet Research Task Force (IRTF) architecture providing communication in and/or through highly stressed networking environments such as space exploration and battlefield networks. Stressed networking environments include those with intermittent (predictable and unknown) connectivity, large and/or variable delays, and high bit error rates. To provide its services over existing domain specific protocols, the DTN protocols reside at the application layer of the TCP/IP stack, forming a store-and-forward overlay network. The key capabilities of the Bundle Protocol include custody-based reliability, the ability to cope with intermittent connectivity, the ability to take advantage of scheduled and opportunistic connectivity, and late binding of names to addresses.

Segui, John S.↗

Evaluation of various approaches for assessing dose indicators and patient organ doses resulting from radiotherapy cone-beam CT

Purpose: The aim of this study was to evaluate various approaches for assessing patient organ doses resulting from radiotherapy cone-beam CT (CBCT), by the use of thermoluminescent dosimeter (TLD) measurements in anthropomorphic phantoms, a Monte Carlo based dose calculation software, and different dose indicators as presently defined. Methods: Dose evaluations were performed on a CBCT Elekta XVI (Elekta, Crawley, UK) for different protocols and anatomical regions. The first part of the study focuses on using PCXMC software (PCXMC 2.0, STUK, Helsinki, Finland) for calculating organ doses, adapting the input parameters to simulate the exposure geometry, and beam dose distribution in an appropriate way. The calculated doses were compared to readouts of TLDs placed in an anthropomorphic Rando phantom. After this validation, the software was used for analyzing organ dose variability associated with patients’ differences in size and gender. At the same time, various dose indicators were evaluated: kerma area product (KAP), cumulative air-kerma at the isocenter (K{sub air}), cone-beam dose index, and central cumulative dose. The latter was evaluated in a single phantom and in a stack of three adjacent computed tomography dose index phantoms. Based on the different dose indicators, a set of coefficients was calculated to estimate organ doses for a range of patient morphologies, using their equivalent diameters. Results: Maximum organ doses were about 1 mGy for head and neck and 25 mGy for chest and pelvis protocols. The differences between PCXMC and TLDs doses were generally below 10% for organs within the field of view and approximately 15% for organs at the boundaries of the radiation beam. When considering patient size and gender variability, differences in organ doses up to 40% were observed especially in the pelvic region; for the organs in the thorax, the maximum differences ranged between 20% and 30%. Phantom dose indexes provided better correlation with organ doses than K{sub air} and KAP, with average ratios ranging between 0.9 and 1.1 and variations for different organs and protocols below 20%. The triple phantom setup allowed us to take into account scatter dose contributions, but nonetheless, the correlation with the evaluated organ doses was not improved with this method. Conclusions: The simulation of rotational geometry and of asymmetric beam distribution by means of PCXMC 2.0 enabled us to determine patient organ doses depending on weight, height and gender. Alternatively, the measurement of an in phantom dose indicator combined with proper correction coefficients can be a useful tool for a first dose estimation of in-field organs. The data and coefficients provided in this study can be applied to any patient undergoing a scan by an Elekta XVI equipment.

60 APPLIED LIFE SCIENCES↗

in silico Whole Genome Sequencer & Analyzer (iWGS): A Computational Pipeline to Guide the Design and Analysis of de novo Genome Sequencing Studies

The availability of genomes across the tree of life is highly biased toward vertebrates, pathogens, human disease models, and organisms with relatively small and simple genomes. Recent progress in genomics has enabled the de novo decoding of the genome of virtually any organism, greatly expanding its potential for understanding the biology and evolution of the full spectrum of biodiversity. The increasing diversity of sequencing technologies, assays, and de novo assembly algorithms have augmented the complexity of de novo genome sequencing projects in nonmodel organisms. To reduce the costs and challenges in de novo genome sequencing projects and streamline their experimental design and analysis, we developed iWGS (in silico Whole Genome Sequencer and Analyzer), an automated pipeline for guiding the choice of appropriate sequencing strategy and assembly protocols. iWGS seamlessly integrates the four key steps of a de novo genome sequencing project: data generation (through simulation), data quality control, de novo assembly, and assembly evaluation and validation. The last three steps can also be applied to the analysis of real data. iWGS is designed to enable the user to have great flexibility in testing the range of experimental designs available for genome sequencing projects, and supports all major sequencing technologies and popular assembly tools. Three case studies illustrate how iWGS can guide the design of de novo genome sequencing projects, and evaluate the performance of a wide variety of user-specified sequencing strategies and assembly protocols on genomes of differing architectures. iWGS, along with a detailed documentation, is freely available at https://github.com/zhouxiaofan1983/iWGS.

59 BASIC BIOLOGICAL SCIENCES↗

Validation of Multisystem Countermeasures Protocol for Spaceflight during Antarctica Winter-over at Palmer Station (Palmer Countermeasures)

Stressors associated with spaceflight induce persistent immune compromise in astronauts which increase subclinical latent virus reactivation. In select crews, adverse clinical events have been documented. Antarctica winter-over (AWO) mission most closely reproduces these mission stressors: prolonged deployment, extreme environment, circadian misalignment, isolation, station lifestyle, and personal risk. The US maintains three primary stations in Antarctica: South Pole Station, McMurdo, and Palmer. Previous studies suggest that stations located near the interior of Antarctica (South Pole, McMurdo) have confounding effects on the immune system due to persistent hypobaric hypoxia. We hypothesized that winter-over at a coastal station (Palmer) would be more akin to spaceflight due to its normoxic but still extreme environment. Therefore, AWO at Palmer Station was selected, and validated in a pilot study [2], as the platform for testing and validating the effectiveness of an immune-restorative countermeasure protocol designed for deep space missions. Specifics include diet modifications, nutritional supplementation (vitamin D, probiotic, etc.), prescribed aerobic and resistive exercise, and a protocol of stress relieving virtual reality exercises. A multitude of biological sample types, including blood, saliva, and hair will be collected in tandem with the countermeasures in order to examine the combined effectiveness of the countermeasures. Samples and logs from subjects will be transported from Palmer Station to Johnson Space Center for further processing and distribution to co-investigators at the end of each winter-over. Extracted samples will be analyzed by appropriate testing platforms (Multiplex, qPCR, ELISA, etc.) to monitor alterations in leukocyte distribution, T cell and NK function, cytokine profiles, reactivation of latent herpesviruses, and nutritional factors. The data collected will be compared to a control year in which no countermeasures were deployed to evaluate the overall effectiveness of the analog and to validate the candidate immune countermeasure strategy. AWO 2023 concluded with the 4th in-mission timepoint conducted in September 2023. Samples for 16 subjects, including blood, saliva, hair, surveys, and PCR data, were all successfully returned from Antarctica to NASA/JSC mid-November 2023. Samples have since been distributed to co-investigators for further processing and analysis. With the completion of the first countermeasure year, preliminary data on the effectiveness of the deep-space protocol is being evaluated, however, no conclusions can be drawn yet until the completion of the second AWO countermeasure year, AWO 2024. AWO 2024 commenced in late-March 2024, with 13 subjects consenting and performing their baseline data collections (BDCs). Unique to the 2024 deployment, NSF lifted certain COVID restrictions and rallied the crewmembers in Punta Arenas, Chile. All NSF activities were transferred to this location and NASA was allowed, for the first time, to perform consent briefings, baseline samplings and training in person. This augment greatly increased the likelihood of success for the overwinter activities.

Cody L Gutierrez↗

Validation of Multisystem Countermeasures Protocol for Spaceflight during Antarctica Winter-over at Palmer Station (Palmer Countermeasures)

Stressors associated with spaceflight induce persistent immune compromise in astronauts which increase subclinical latent virus reactivation. In select crews, adverse clinical events have been documented. Antarctica winter-over (AWO) mission most closely reproduces these mission stressors: prolonged deployment, extreme environment, circadian misalignment, isolation, station lifestyle, and personal risk. The US maintains three primary stations in Antarctica: South Pole Station, McMurdo, and Palmer. Previous studies suggest that stations located near the interior of Antarctica (South Pole, McMurdo) have confounding effects on the immune system due to persistent hypobaric hypoxia. We hypothesized that winter-over at a coastal station (Palmer) would be more akin to spaceflight due to its normoxic but still extreme environment. Therefore, AWO at Palmer Station was selected, and validated in a pilot study, as the platform for testing and validating the effectiveness of an immune-restorative countermeasure protocol designed for deep space missions. Specifics include diet modifications, nutritional supplementation (vitamin D, probiotic, etc.), prescribed aerobic and resistive exercise, and a protocol of stress relieving virtual reality exercises. A multitude of biological sample types, including blood, saliva, and hair will be collected in tandem with the countermeasures in order to examine the combined effectiveness of the countermeasures. Samples and logs from subjects will be transported from Palmer Station to Johnson Space Center for further processing and distribution to co-investigators at the end of each winter-over. Extracted samples will be analyzed by appropriate testing platforms (Multiplex, qPCR, ELISA, etc.) to monitor alterations in leukocyte distribution, T cell and NK function, cytokine profiles, reactivation of latent herpesviruses, and nutritional factors. The data collected will be compared to a control year in which no countermeasures were deployed to evaluate the overall effectiveness of the analog and to validate the candidate immune countermeasure strategy. AWO 2023 concluded with the 4th in-mission timepoint conducted in September 2023. Samples for 16 subjects, including blood, saliva, hair, surveys, and PCR data, were all successfully returned from Antarctica to NASA/JSC mid-November 2023. Samples have since been distributed to co-investigators for further processing and analysis. With the completion of the first countermeasure year, preliminary data on the effectiveness of the deep-space protocol is being evaluated, however, no conclusions can be drawn yet until the completion of the second AWO countermeasure year, AWO 2024. AWO 2024 commenced in late-March 2024, with 13 subjects consenting and performing their baseline data collections (BDCs). Unique to the 2024 deployment, NSF lifted certain COVID restrictions and rallied the crewmembers in Punta Arenas, Chile. All NSF activities were transferred to this location and NASA was allowed, for the first time, to perform consent briefings, baseline samplings and training in person. This augment greatly increased the likelihood of success for the overwinter activities.

Cody L Gutierrez↗

High-performance End-to-End Integrity Verification on Big Data Transfer

The scale of scientific data generated by experimental facilities and simulations in high-performance computing facilities has been proliferating with the emergence of IoT-based big data. In many cases, this data must be transmitted rapidly and reliably to remote facilities for storage, analysis, or sharing, for the Internet of Things (IoT) applications. Simultaneously, IoT data can be verified using a checksum after the data has been written to the disk at the destination to ensure its integrity. However, this end-to-end integrity verification inevitably creates overheads (extra disk I/O and more computation). Thus, the overall data transfer time increases. In this article, we evaluate strategies to maximize the overlap between data transfer and checksum computation for astronomical observation data. Specifically, we examine file-level and block-level (with various block sizes) pipelining to overlap data transfer and checksum computation. We analyze these pipelining approaches in the context of GridFTP, a widely used protocol for scientific data transfers. Theoretical analysis and experiments are conducted to evaluate our methods. The results show that block-level pipelining is effective in maximizing the overlap mentioned above, and can improve the overall data transfer time with end-to-end integrity verification by up to 70% compared to the sequential execution of transfer and checksum, and by up to 60% compared to file-level pipelining.

data integrity↗

A set of 4D pediatric XCAT reference phantoms for multimodality research

Purpose: The authors previously developed an adult population of 4D extended cardiac-torso (XCAT) phantoms for multimodality imaging research. In this work, the authors develop a reference set of 4D pediatric XCAT phantoms consisting of male and female anatomies at ages of newborn, 1, 5, 10, and 15 years. These models will serve as the foundation from which the authors will create a vast population of pediatric phantoms for optimizing pediatric CT imaging protocols. Methods: Each phantom was based on a unique set of CT data from a normal patient obtained from the Duke University database. The datasets were selected to best match the reference values for height and weight for the different ages and genders according to ICRP Publication 89. The major organs and structures were segmented from the CT data and used to create an initial pediatric model defined using nonuniform rational B-spline surfaces. The CT data covered the entire torso and part of the head. To complete the body, the authors manually added on the top of the head and the arms and legs using scaled versions of the XCAT adult models or additional models created from cadaver data. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from a template XCAT phantom (male or female 50th percentile adult) to the target pediatric model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. The masses of the organs in each phantom were matched to the reference values given in ICRP Publication 89. The new reference models were checked for anatomical accuracy via visual inspection. Results: The authors created a set of ten pediatric reference phantoms that have the same level of detail and functionality as the original XCAT phantom adults. Each consists of thousands of anatomical structures and includes parameterized models for the cardiac and respiratory motions. Based on patient data, the phantoms capture the anatomic variations of childhood, such as the development of bone in the skull, pelvis, and long bones, and the growth of the vertebrae and organs. The phantoms can be combined with existing simulation packages to generate realistic pediatric imaging data from different modalities. Conclusions: The development of patient-derived pediatric computational phantoms is useful in providing variable anatomies for simulation. Future work will expand this ten-phantom base to a host of pediatric phantoms representative of the public at large. This can provide a means to evaluate and improve pediatric imaging devices and to optimize CT protocols in terms of image quality and radiation dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

Phase III integrated water recovery testing at MSFC - Design, plans, and protocols

A series of tests is being conducted at the NASA Marshall Space Flight Center (MSFC) to evaluate the performance of a closed-loop water recovery system. Testing will be conducted at various levels of integration and loop-closure, culminating in complete closure of the water system with man-in-the-loop. This paper summarizes the test goals and objectives as well as the system design, plans, and protocols which have been established.

Bagdigian, Robert M.↗

SU-F-T-388: Comparison of Biophysical Indices in Hippocampal-Avoidance Whole Brain VMAT and IMRT Radiation Therapy Treatment Plans

Purpose: To compare biophysical indices of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiation Therapy (IMRT) treatment plans for whole brain radiation therapy following the NRG-CC001 protocol. Methods: In this retrospective study, a total of fifteen patients were planned with Varian Eclipse Treatment Planning System using VMAT (RapidArc) and IMRT techniques. The planning target volume (PTV) was defined as the whole brain volume excluding a uniform three-dimensional 5mm expansion of the hippocampus volume. Prescribed doses in all plans were 30 Gy delivered over 10 fractions normalized to a minimum of 95% of the target volume receiving 100% of the prescribed dose. The NRG Oncology protocol guidelines were followed for contouring and dose-volume constraints. A single radiation oncologist evaluated all treatment plans. Calculations of statistical significance were performed using Student’s paired t-test. Results: All VMAT and IMRT plans met the NRG-CC001 protocol dose-volume criteria. The average equivalent uniform dose (EUD) for the PTV for VMAT vs. IMRT was respectively (19.05±0.33 Gy vs. 19.38±0.47 Gy) for α/β of 2 Gy and (19.47±0.30 Gy vs. 19.84±0.42 Gy) for α/β of 10 Gy. For the PTV, the average mean and maximum doses were 2% and 5% lower in VMAT plans than in IMRT plans, respectively. The average EUD and the normal tissue complication probability (NTCP) for the hippocampus in VMAT vs. IMRT plans were (15.28±1.35 Gy vs. 15.65±0.99 Gy, p=0.18) and (0.305±0.012 Gy vs. 0.308±0.008 Gy, p=0.192), respectively. The average EUD and NTCP for the optic chiasm were both 2% higher in VMAT than in IMRT plans. Conclusion: Though statistically insignificant, VMAT plans indicate a lower hippocampus EUD than IMRT plans. Also, a small variation in NTCP was found between plans.

60 APPLIED LIFE SCIENCES↗

Chapter 11: Sample Design Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

Evaluating an energy efficiency program requires assessing the total energy and demand saved through all of the energy efficiency measures provided by the program. For large programs, the direct assessment of savings for each participant would be cost-prohibitive. Even if a program is small enough that a full census could be managed, such an undertaking would almost always be an inefficient use of evaluation resources. The bulk of this chapter describes methods for minimizing and quantifying sampling error. Measurement error and regression error are discussed in various contexts in other chapters.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluating resilience of DNP3-controlled SCADA systems against event buffer flooding

The DNP3 protocol is widely used in SCADA systems (particularly electrical power) as a means of communicating observed sensor state information back to a control center. Typical architectures using DNP3 have a two level hierarchy, where a specialized data aggregator device receives observed state from devices within a local region, and the control center collects the aggregated state from the data aggregator. The DNP3 communication between control center and data aggregator is asynchronous with the DNP3 communication between data aggregator and relays; this leads to the possibility of completely filling a data aggregator's buffer of pending events, when a relay is compromised or spoofed and sends overly many (false) events to the data aggregator. This paper investigates how a real-world SCADA device responds to event buffer flooding. A Discrete-Time Markov Chain (DTMC) model is developed for understanding this. The DTMC model is validated by a Moebius simulation model and data collected on real SCADA testbed.

42 ENGINEERING↗