Two hundred years of flight in America: A bicentennial survey

The first recorded balloon ascension in America took place on June 19, 1784, when an unmanned balloon was raised in a public demonstration at Bladensburg, Maryland. On June 24, 1784, a thirteen-year-old boy ascended in the same balloon. The history of actual flight during the nineteenth century was entirely concerned with balloons except for several gliders and models leading to the coming of the airship and the aircraft. The history of practical flight in America begins in the twentieth century. The described developments related to aerostatics are concerned with balloons, rigid airships, and blimps. In a review of the evolution of aeronautics, attention is given to general aviation and its search for a market, trends in military aeronautics, and commercial aviation. It is pointed out that American air transport had its birth on New Year's Day, 1914, at Tampa Bay, Florida. The evolution of astronautics during the period from 1957 to 1976 is also examined, taking into account scientific satellites, the Apollo project, the exploration of the planets with the aid of unmanned spacecraft, strategic reconnaissance satellites, missile alarm satellites, instrumental satellites for detecting nuclear and thermonuclear explosions, weather satellites, communications satellites, and earth resource survey and geodetic satellites.

Emme, E. M.↗

Fiber optic-based biosensor

The NRL fiber optic biosensor is a device which measures the formation of a fluorescent complex at the surface of an optical fiber. Antibodies and DNA binding proteins provide the mechanism for recognizing an analyze and immobilizing a fluorescent complex on the fiber surface. The fiber optic biosensor is fast, sensitive, and permits analysis of hazardous materials remote from the instrumentation. The fiber optic biosensor is described in terms of the device configuration, chemistry for protein immobilization, and assay development. A lab version is being used for assay development and performance characterization while a portable device is under development. Antibodies coated on the fiber are stable for up to two years of storage prior to use. The fiber optic biosensor was used to measure concentration of toxins in the parts per billion (ng/ml) range in under a minute. Immunoassays for small molecules and whole bacteria are under development. Assays using DNA probes as the detection element can also be used with the fiber optic sensor, which is currently being developed to detect biological warfare agents, explosives, pathogens, and toxic materials which pollute the environment.

Ligler, Frances S.↗

Production of Samples of Individual Radioxenon Isotopes Through Neutron Irradiation of Stable Xenon Gas

The Spectral Deconvolution Analysis Tool (SDAT) software was developed to improve counting statistics and detection limits for nuclear explosion radionuclide measurements. SDAT utilizes spectral deconvolution spectroscopy techniques and can analyze both β-γ coincidence spectra for radioxenon isotopes and high-resolution HPGe spectra from aerosol monitors. The deconvolution algorithm of the SDAT requires a library of β-γ coincidence spectra of individual radioxenon isotopes to determine isotopic ratios in a sample. In order to get experimentally produced spectra of the individual isotopes we have irradiated enriched samples of 130Xe, 132Xe, and 134Xe gas with a neutron beam from the TRIGA reactor at The University of Texas. The samples produced were counted in an Automated Radioxenon Sampler/Analyzer (ARSA) style β-γ coincidence detector. The spectra produced show that this method of radioxenon production yields samples with very high purity of the individual isotopes for 131mXe and 135Xe and a sample with a substantial 133mXe to 133Xe ratio.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

The Use of the BAT Instrument on SWIFT for the Detection of Prompt Gamma-Ray Emission from Novae

Gamma-rays are expected to be emitted during and immediately following a nova explosion due to the annihilation of positrons emitted by freshly produced short-lived radioactive isotopes. The expected gammaray emission is relatively short-lived and as nova explosions are unpredictable, the best chance of detecting the gamma-rays is with n wide field instrument. At the time when the flux is expected to rcach its peak, most of the gamma-ray production is at depths such that the photons suffer several Compton scatterings before escaping, degrading their energy down to the hard X-ray band (10s of keV). SWIFT/BAT is a very wide field coded mask instrument working in the energy band 14-190 keV and so is very well suited to the search for such gamma-rays. A retrospective search is being made in the BAT data for evidence for gamma-ray emission from the direction of novae at around the time of their explosion. So far the only positive detection is of RS Ophiuchi and in this case the emission is probably due to shock heating.

Skinner, Gerry↗

Sticky bomb detection with other implications for vehicle security.

A 'sticky bomb' is a type of improvised explosive device (IED) placed on a motor vehicle by (for example) a terrorist. The bomb is typically attached with adhesive ('duct') tape, or with magnets. This paper reports some preliminary results for a very rudimentary demonstration of two techniques for detecting the placement of a sticky bomb on a motor vehicle. The two techniques are tire pressure and magnetic measurements. There are other possible security applications for these techniques as well.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A Preliminary Explosion Seismic Spectral Model for Saturated/Hard Rock

This short technical report describes a new seismic spectral model for chemical and nuclear explosions in saturated and/or hard rock. Results from the Source Physics Experiments (SPE) indicate that existing explosion spectral models can be poor fits to small and/or over-buried explosions. Here we develop a preliminary improved explosion model to fit both SPE and historic nuclear explosion data. The model is based on revising the Mueller and Murphy (1972) and Denny and Johnson (1991) seismic spectral models. A FORTRAN code was developed to provide the spectral models in SAC format for use in explosion monitoring applications such as detection and yield estimation. This model should be considered preliminary and work is underway to better generalize and expand the model to include explosions in dry porous and/or soft rock media and to better fit explosion S-waves.

58 GEOSCIENCES↗

The theory of gamma-ray emergence in supernova 1987A

It was anticipated that the decay of Co-56 to Fe-56 in SN1987A would give rise to detectable gamma-ray emission at 847 and 1238 keV with a peak flux of 0.001 photon/sq cm/s about one year after the explosion. Both these lines were detected in August, with a strength within a factor of two of 0.001 photon/sq cm/s, but about six months earlier than predicted. It is shown here that the early emergence of gamma-rays can be accounted for in a 'mixed' model in which an approximately isotropic process destroys chemical segregation with respect to radial mass coordinate and velocity.

Pinto, Philip A.↗

The Source Physics Experiment (SPE) Science Plan (Version 2.4c)

The Source Physics Experiment (SPE) series is a long-term NNSA research and development effort designed to improve U.S. arms control and nuclear nonproliferation verification and monitoring capabilities. The findings from the SPE will advance the United States’ nuclear explosion monitoring capabilities, particularly with respect to detection, discrimination and determination of yields associated with small nuclear explosions that can be lost amid the noisy seismo-acoustic background from other sources. The data generated from the SPE, a series of well-designed and recorded chemical explosions, will contribute to the development and validation of first-principles explosive source generated seismo-acoustic modeling codes. These codes will then facilitate the update of semi-empirical methods, currently based on historic test site data, such that key explosion observables can be reproduced, thus improving confidence in nuclear test monitoring in new areas and/or under novel emplacement conditions. The overall SPE project is comprised of both the development of the new explosion simulation codes and the chemical explosion test series. The chemical explosion test series will generate the empirical data required to both develop and validate the new simulation codes.

58 GEOSCIENCES↗

The Source Physics Experiment (SPE) Science Plan

The Source Physics Experiment (SPE) series is a long-term NNSA research and development effort designed to improve U.S. arms control and nuclear nonproliferation verification and monitoring capabilities. The findings from the SPE will advance the United States’ nuclear explosion monitoring capabilities, particularly with respect to detection, discrimination and determination of yields associated with small nuclear explosions that can be lost amid the noisy seismo-acoustic background from other sources. The data generated from the SPE, a series of well-designed and recorded chemical explosions, will contribute to the development and validation of first-principles explosive source generated seismo-acoustic modeling codes. These codes will then facilitate the update of semi-empirical methods, currently based on historic test site data, such that key explosion observables can be reproduced, thus improving confidence in nuclear test monitoring in new areas and/or under novel emplacement conditions. The overall SPE project is comprised of both the development of the new explosion simulation codes and the chemical explosion test series. The chemical explosion test series will generate the empirical data required to both develop and validate the new simulation codes.

58 GEOSCIENCES↗

Monitoring/Verification using DMS: TATP Example

Field-rugged and field-programmable differential mobility spectrometry (DMS) networks provide highly selective, universal monitoring of vapors and aerosols at detectable levels from persons or areas involved with illicit chemical/biological/explosives (CBE) production. CBE sensor motes used in conjunction with automated fast gas chromatography with DMS detection (GC/DMS) verification instrumentation integrated into situational operations management systems can be readily deployed and optimized for changing application scenarios. The feasibility of developing selective DMS motes for a 'smart dust' sampling approach with guided, highly selective, fast GC/DMS verification analysis is a compelling approach to minimize or prevent the use of explosives or chemical and biological weapons in terrorist activities. Two peroxide-based liquid explosives, triacetone triperoxide (TATP) and hexamethylene triperoxide diamine (HMTD), are synthesized from common chemicals such as hydrogen peroxide, acetone, sulfuric acid, ammonia, and citric acid (Figure 1). Recipes can be readily found on the Internet by anyone seeking to generate sufficient quantities of these highly explosive chemicals to cause considerable collateral damage. Detection of TATP and HMTD by advanced sensing systems can provide the early warning necessary to prevent terror plots from coming to fruition. DMS is currently one of the foremost emerging technologies for the separation and detection of gas-phase chemical species. This is due to trace-level detection limits, high selectivity, and small size. DMS separates and identifies ions at ambient pressures by utilizing the non-linear dependence of an ion's mobility on the radio frequency (rf) electric field strength. GC is widely considered to be one of the leading analytical methods for the separation of chemical species in complex mixtures. Advances in the technique have led to the development of low-thermal-mass fast GC columns. These columns are capable of completing runs in less than 3 minutes. Fast GC columns are also more compact than their traditional counterparts. An earlier collaborative effort involving these authors optimized a handheld, fast GC/DMS, equipped with a non-rad ionization source, for the detection of TATP (Figure 2). The unit combines the separation capabilities of GC with the selectivity of DMS. Analytes are identified both by their elution time from the column and by the characteristic response in the DMS spectrum. Analysis times required to obtain results for these analytes are approximately 80 seconds for TATP and 160 seconds for HMTD (Figure 3). The limit of detection for both TATP and HMTD is approximately 1 ng/{micro}L. Substances that could interfere with the detection of peroxide-based explosives have been studied. Both the GC elution time and the DMS spectral peak locations were unique and do not hinder the detection of either TATP or HMTD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AN X-RAY STUDY OF SUPERNOVA REMNANT N49 AND SOFT GAMMA-RAY REPEATER 0526-66 IN THE LARGE MAGELLANIC CLOUD

We report on the results from our deep Chandra observation (120 ks) of the supernova remnant (SNR) N49 and soft gamma-ray repeater (SGR) 0526-66 in the Large Magellanic Cloud. We firmly establish the detection of an ejecta 'bullet' beyond the southwestern boundary of N49. The X-ray spectrum of the bullet is distinguished from that of the main SNR shell, showing significantly enhanced Si and S abundances. We also detect an ejecta feature in the eastern shell, which shows metal overabundances similar to those of the bullet. If N49 was produced by a core-collapse explosion of a massive star, the detected Si-rich ejecta may represent explosive O-burning or incomplete Si-burning products from deep interior of the SN. On the other hand, the observed Si/S abundance ratio in the ejecta may favor Type Ia origin for N49. We refine the Sedov age of N49, {tau}{sub Sed} {approx} 4800 yr, with the explosion energy E{sub 0} {approx} 1.8 Multiplication-Sign 10{sup 51} erg. Our blackbody (BB) + power law (PL) model for the quiescent X-ray emission from SGR 0526-66 indicates that the PL photon index ({Gamma} {approx} 2.5) is identical to that of PSR 1E1048.1-5937, the well-known candidate transition object between anomalous X-ray pulsars and SGRs. Alternatively, the two-component BB model implies X-ray emission from a small (R {approx} 1 km) hot spot(s) (kT {approx} 1 keV) in addition to emission from the neutron star's cooler surface (R {approx} 10 km, kT {approx} 0.4 keV). There is a considerable discrepancy in the estimated column toward 0526-66 between BB+PL and BB+BB model fits. Discriminating these spectral models would be crucial to test the long-debated physical association between N49 and 0526-66.

79 ASTRONOMY AND ASTROPHYSICS↗

Laser-Based Remote Sensing of Explosives by a Differential Absorption and Scattering Method

A multifunctional IR parametric laser system is developed and tested for remote detection and identification of atmospheric gases, including explosive and chemically aggressive substances. Calculations and experimental studies of remote determination of the spectroscopic parameters of the best known explosive substances TNT, RDX, and PETN are carried out. The feasibility of high sensitivity detection (~1 ppm) of these substances with the aid of a multifunctional IR parametric light source by differential absorption and scattering is demonstrated.

42 ENGINEERING↗

High Throughput Argon-37 Field System

We report Pacific Northwest National Laboratory (PNNL) has developed a unique fieldable 37 Ar measurement system designed to measure 37 Ar activity concentrations from soil gas samples to detect above ground and underground nuclear explosions. The Argon-37 Field System is modular in design to accommodate both chemical processing and nuclear detection. The system can be packed into shipping crates and shipped to a location near where the sampling is taking place. The system can process six 2-m 3 whole-air samples in 24 hours and can measure the 37 Ar activity in each of the samples using six proportional counters. The proportional counters, designed and built at PNNL, are surrounded with both active and passive shielding to reduce background and can achieve a minimum detection concentration of 10 mBq/m 3 of 37 Ar in whole-air equivalent. The Argon-37 Field System has undergone extensive testing against rigorous requirements to assure the system meets the needs of the noble gas nuclear explosion monitoring community.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

CTBT infrasound network performance to detect the 2013 Russian fireball event

The explosive fragmentation of the 2013 Chelyabinsk meteorite generated a large airburst with an equivalent yield of 500 kT TNT. It is the most energetic event recorded by the infrasound component of the Comprehensive Nuclear-Test-Ban Treaty-International Monitoring System (CTBT-IMS), globally detected by 20 out of 42 operational stations. This study performs a station-by-station estimation of the IMS detection capability to explain infrasound detections and nondetections from short to long distances, using the Chelyabinsk meteorite as global reference event. Investigated parameters influencing the detection capability are the directivity of the line source signal, the ducting of acoustic energy, and the individual noise conditions at each station. Findings include a clear detection preference for stations perpendicular to the meteorite trajectory, even over large distances. Only a weak influence of stratospheric ducting is observed for this low-frequency case. As a result, a strong dependence on the diurnal variability of background noise levels at each station is observed, favoring nocturnal detections.

58 GEOSCIENCES↗

Towards an Empirically Based Parametric Explosion Spectral Model

Small underground nuclear explosions need to be confidently detected, identified, and characterized in regions of the world where they have never before been tested. The focus of our work is on the local and regional distances (< 2000 km) and phases (Pn, Pg, Sn, Lg) necessary to see small explosions. We are developing a parametric model of the nuclear explosion seismic source spectrum that is compatible with the earthquake-based geometrical spreading and attenuation models developed using the Magnitude Distance Amplitude Correction (MDAC) techniques (Walter and Taylor, 2002). The explosion parametric model will be particularly important in regions without any prior explosion data for calibration. The model is being developed using the available body of seismic data at local and regional distances for past nuclear explosions at foreign and domestic test sites. Parametric modeling is a simple and practical approach for widespread monitoring applications, prior to the capability to carry out fully deterministic modeling. The achievable goal of our parametric model development is to be able to predict observed local and regional distance seismic amplitudes for event identification and yield determination in regions with incomplete or no prior history of underground nuclear testing. The relationship between the parametric equations and the geologic and containment conditions will assist in our physical understanding of the nuclear explosion source.

58 GEOSCIENCES↗

Rogowski Coils For Studies Of Detonator Initiation And Other Diagnostics

Detonators are fundamental to most explosive systems, yet the detonators themselves are rarely diagnosed to determine how well they function or why they fail. To remedy this, various electrical diagnostics were explored, including: Rogowski coils for high fidelity detection of changes in electrical current in explosive bridgewires and how they relate to detonator performance; and radio frequency (RF) antennas to detect any electromagnetic emissions associated with reaction and growth in the explosives. A new type of Rogowski coil is described and some interesting phenomena were detected with the radio frequency antenna.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Long-lasting X-ray emission from type IIb supernova 2011dh and mass-loss history of the yellow supergiant progenitor

Type IIb supernova (SN) 2011dh, with conclusive detection of an unprecedented yellow supergiant (YSG) progenitor, provides an excellent opportunity to deepen our understanding on the massive star evolution in the final centuries toward the SN explosion. In this paper, we report on detection and analyses of thermal X-ray emission from SN IIb 2011dh at ∼500 days after the explosion on Chandra archival data, providing a solidly derived mass-loss rate of a YSG progenitor for the first time. We find that the circumstellar media should be dense, more than that expected from a Wolf-Rayet (W-R) star by one order of magnitude. The emission is powered by a reverse shock penetrating into an outer envelope, fully consistent with the YSG progenitor but not with a W-R progenitor. The density distribution at the outermost ejecta is much steeper than that expected from a compact W-R star, and this finding must be taken into account in modeling the early UV/optical emission from SNe IIb. The derived mass-loss rate is ∼3 × 10{sup –6} M {sub ☉} yr{sup –1} for the mass-loss velocity of ∼20 km s{sup –1} in the final ∼1300 yr before the explosion. The derived mass-loss properties are largely consistent with the standard wind mass-loss expected for a giant star. This is not sufficient to be a main driver to expel nearly all the hydrogen envelope. Therefore, the binary interaction, with a huge mass transfer having taken place at ≳ 1300 yr before the explosion, is a likely scenario to produce the YSG progenitor.

79 ASTRONOMY AND ASTROPHYSICS↗