At least 523 records · Page 29

Soft Computing Application in Fault Detection of Induction Motor

The paper investigates the effectiveness of different patter classifier like Feed Forward Back Propagation (FFBPN), Radial Basis Function (RBF) and Support Vector Machine (SVM) for detection of bearing faults in Induction Motor. The steady state motor current with Park's Transformation has been used for discrimination of inner race and outer race bearing defects. The RBF neural network shows very encouraging results for multi-class classification problems and is hoped to set up a base for incipient fault detection of induction motor. SVM is also found to be a very good fault classifier which is highly competitive with RBF.

99 GENERAL AND MISCELLANEOUS↗

Soft-Fault Detection Technologies Developed for Electrical Power Systems

The NASA Glenn Research Center, partner universities, and defense contractors are working to develop intelligent power management and distribution (PMAD) technologies for future spacecraft and launch vehicles. The goals are to provide higher performance (efficiency, transient response, and stability), higher fault tolerance, and higher reliability through the application of digital control and communication technologies. It is also expected that these technologies will eventually reduce the design, development, manufacturing, and integration costs for large, electrical power systems for space vehicles. The main focus of this research has been to incorporate digital control, communications, and intelligent algorithms into power electronic devices such as direct-current to direct-current (dc-dc) converters and protective switchgear. These technologies, in turn, will enable revolutionary changes in the way electrical power systems are designed, developed, configured, and integrated in aerospace vehicles and satellites. Initial successes in integrating modern, digital controllers have proven that transient response performance can be improved using advanced nonlinear control algorithms. One technology being developed includes the detection of "soft faults," those not typically covered by current systems in use today. Soft faults include arcing faults, corona discharge faults, and undetected leakage currents. Using digital control and advanced signal analysis algorithms, we have shown that it is possible to reliably detect arcing faults in high-voltage dc power distribution systems (see the preceding photograph). Another research effort has shown that low-level leakage faults and cable degradation can be detected by analyzing power system parameters over time. This additional fault detection capability will result in higher reliability for long-lived power systems such as reusable launch vehicles and space exploration missions.

Button, Robert M.↗

Health Monitoring of a Planetary Rover Using Hybrid Particle Petri Nets

This paper focuses on the application of a Petri Net-based diagnosis method on a planetary rover prototype.The diagnosis is performed by using a model-based method in the context of health management of hybrid systems.In system health management, the diagnosis task aims at determining the current health state of a system and the fault occurrences that lead to this state. The Hybrid Particle Petri Nets (HPPN) formalism is used to model hybrid systems behavior and degradation, and to define the generation of diagnosers to monitor the health states of such systems under uncertainty. At any time, the HPPN-based diagnoser provides the current diagnosis represented by a distribution of beliefs over the health states. The health monitoring methodology is demonstrated on the K11 rover. A hybrid model of the K11 is proposed and experimental results show that the approach is robust to real system data and constraints.

health monitoring↗

Robust Disturbance Rejection Rotor Current Control of Doubly-Fed Induction Generators

This article proposes a robust transient disturbance rejection current controller (TDRCC) to improve the transient performance of doubly-fed induction generators (DFIGs) in wind turbines during grid disturbances, such as short circuits. Here, the proposed robust TDRCC replaces the proportional-integral-derivative (PID) current controllers conventionally used in the vector control scheme of the DFIG rotor side converter (RSC). The TDRCC estimates the transient disturbances caused by grid faults or other external disturbances and provides compensation to the DFIG rotor voltage in the current control loops of the RSC to improve the robustness of the controller to disturbance. A sliding-mode current controller (SMCC) is also designed to highlight the transient performance improvement of the DFIG using the TDRCC over the state-of-the-art control methods during grid short circuit faults. Simulation studies are conducted in PSCAD/EMTDC for a 3.6-MW DFIG wind turbine with the proposed TDRCC, the conventional PI controller, and the SMCC, respectively during the most severe balanced three-phase grid short circuit fault specified by the U.S. grid code as well as an unbalance single-phase grid short circuit fault. Hardware experiments are conducted on a 200-W DFIG wind turbine emulator with the three different controllers for the same three-phase short circuit fault. Simulation and hardware experiment results show that the TDRCC reduces the peak rotor current significantly when compared with the PI and SMCC controlled DFIG system and, therefore, would help prolong the lifespan of the DFIG's power electronics and reduce maintenance costs.

42 ENGINEERING↗

Automatic Detection of Electric Power Troubles (ADEPT)

ADEPT is an expert system that integrates knowledge from three different suppliers to offer an advanced fault-detection system, and is designed for two modes of operation: real-time fault isolation and simulated modeling. Real time fault isolation of components is accomplished on a power system breadboard through the Fault Isolation Expert System (FIES II) interface with a rule system developed in-house. Faults are quickly detected and displayed and the rules and chain of reasoning optionally provided on a Laser printer. This system consists of a simulated Space Station power module using direct-current power supplies for Solar arrays on three power busses. For tests of the system's ability to locate faults inserted via switches, loads are configured by an INTEL microcomputer and the Symbolics artificial intelligence development system. As these loads are resistive in nature, Ohm's Law is used as the basis for rules by which faults are located. The three-bus system can correct faults automatically where there is a surplus of power available on any of the three busses. Techniques developed and used can be applied readily to other control systems requiring rapid intelligent decisions. Simulated modelling, used for theoretical studies, is implemented using a modified version of Kennedy Space Center's KATE (Knowledge-Based Automatic Test Equipment), FIES II windowing, and an ADEPT knowledge base. A load scheduler and a fault recovery system are currently under development to support both modes of operation.

Wang, Caroline↗

Firmware Architecture of the ARMADAS Bolting Robot

The Automated Reconfigurable Mission Adaptive Digital Assembly Systems (ARMADAS) project, under development at NASA Ames Research Center, has demonstrated on-ground autonomous robotic assembly of extensive digital structures, and it is now moving forward towards in-space demonstration. The ARMADAS system comprises of the operation software, the operation user interface (opsUI), and a swarm of robots. The robotic system consists of a multitude of collaborative agents specifically designed to transport, place and bolt the building blocks, called voxels (volumetric pixels). This paper focuses on the bolting robot, referred to as Mobile Metamaterial Internal Co-Integrator (MMIC-I). MMIC-I is a battery-powered crawling robot. It navigates the structure through extension, contraction and gripping. Two distinct controller boards operate the robot's two symmetric modules, referred to as module A and B. Board A is the master board: it coordinates motion planning and motion primitives execution, hosts the WiFi client, performs periodic self-assessment and system idle check and triggers faults if anomalies are detected. Board B periodically sends a heartbeat to board A, through a wired communication channel that uses the Serial protocol. Additionally, board A's WiFi client receives heartbeat packet requests or motion/bolting commands from a dedicated server board, and acknowledges reception sending back a response heartbeat packet containing information about the overall robot status, e. g. electrical current and voltage values, target and actual angles, operating mode, fault status. Whenever a motion command is sent, the motion planning section of the firmware determines the current robot configuration, using Inertial Measurement Unit readings and the motors Pulse Width Modulation values. Afterwards, it calculates the list of primitives needed to reach the target state, and controls their execution in the proper order. MMIC-I can receive and execute motion and bolting commands only when it is in operational mode. MMIC-I has three operating modes: standby, operational and safed. Standby mode is automatically entered upon startup. While in standby mode, all motors are powered off, and the only accepted commands are the ones relative to a change of mode and heartbeat packet request. Fault detection causes the robot to automatically enter safed or standby mode. Whenever the detected fault occurs within a motion and requires immediate intervention, e. g. an over-current situation, the robot enters safed mode. Safed mode powers off all motors except for the locomotion module, thus preventing the robot from collapsing. Conversely, when the detected fault doesn't require immediate intervention (low battery warning, for instance), the robot enters standby mode after completing the ongoing motion. This paper provides a detailed discussion of MMIC-I's firmware architecture. It accurately describes the implementation approach for each module: sensor data reading, motor control and actuation, WiFi server-client communication, intra-boards Serial communication, operating modes and autonomous fault detection, motion planning, coordination and execution, etc. Moreover, in support of the software description, this paper includes a thorough characterization of MMIC-I's hardware and avionics.

In-space assembly↗

Novel Fault Location Method for Power Systems Based on Attention Mechanism and Double Structure GRU Neural Network

Fault location is one of the most essential techniques to maintain the stable operation of power systems. A fast and accurate fault location allows operators to restore power grids faster and avoid economic losses. Conventional methods rely on expert knowledge to extract the necessary features (e.g. DWT, DFT). For large systems, more coupling effects of transmission lines require more complex feature engineering, and incomplete features can easily introduce large errors. To overcome this, a deep learning approach without manual feature extraction is introduced to the fault location model under big data application. Towards this end, in the proposed method, the attention mechanism, the Bi-GRU and a dual structure network are applied to analyze the current data from different perspectives. Complete information for the fault features is extracted for the fault location. Based on a time series model and benefit from the ability to internally acquire the information architecture of faulty line, the established model is adaptive to the power grids with very complex topologies. Simulation results indicate that the proposed double-structure model reduces the maximum error and is less affected by noise. In comparison with different structures and different models, the proposed method shows better performance in IEEE 39-bus system.

42 ENGINEERING↗

Detecting faults in wind turbines

A wind turbine generator fault detection method is described. The method includes acquiring current data from a wind turbine generator during operation, determining frequency demodulated signals and amplitude demodulated signals by frequency demodulating and amplitude demodulating the current data, resampling the frequency and amplitude demodulated signals corresponding to the current data, monitoring a frequency spectra of the resampled frequency and amplitude demodulated signals corresponding to the current data to identify one or more excitations in the frequency spectra. In response to identifying one or more excitations in the frequency spectra at one or more of the variable fault characteristic frequencies, the method includes generating and transmitting an alert that indicates that a wind turbine generator fault is detected.

17 WIND ENERGY↗

Topological insulators/superconductors: Potential future electronic materials

A new material called topological insulator has been discovered and becomes one of the fastest growing field in condensed matter physics. Topological insulator is a new quantum phase of matter which has Dirac-like conductivity on its surface, but bulk insulator through its interior. It is considered a challenging problem for the surface transport measurements because of dominant internal conductance due to imperfections of the existing crystals of topological insulators. By a proper method, the internal bulk conduction can be suppressed in a topological insulator, and permit the detection of the surface currents which is necessary for future fault-tolerant quantum computing applications. Doped topological insulators have depicted a large variety of bulk physical properties ranging from magnetic to superconducting behaviors. By chemical doping, a TI can change into a bulk superconductor. Nb{sub x}Bi{sub 2}Se{sub 3} is shown to be a superconductor with T{sub c} ∼ 3.2 K, which could be a potential candidate for a topological superconductor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resilience Analysis of DC Microgrids under Denial of Service Threats

This paper develops a resilience analysis framework to study the fault ride-through capability of direct current (DC) microgrids in unknown denial of service (DoS) cyber incidents. DoS can be a frequent threat to DC microgrids with advanced controllers that hinge on active information exchanges: it can paralyze data communications and cause control ineptness or even system instability. Furthermore, we show that temporal DoS incidents render the DC microgrid cyber-physical topology and parameters time-varying and cause them to jump between faulty conditions. As existing DC microgrid stability analysis results are primarily developed from time-invariant systems, they might not be valid for the DoS interrupted systems. In this paper, we seek to study whether a DC microgrid is resilient against time-varying unknown DoS incidents. The problem is formulated as a stability analysis problem for a system with randomly switching dynamics. Scalable conditions are developed to provide provable resilience guarantees. In addition, we exploit the special structure of the conditions to yield quantified resilience measure by convex optimization techniques. As a result, the measure can be used for the evaluation of the resilience of different DC microgrid design against DoS incidents. We demonstrate the effectiveness of the proposed work using simulation case studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Root Cause Analysis of AC Overcurrent in July 2020 San Fernando Disturbance

On July 7 2020, approximately 1,000 MW reduction in solar photovoltaic (PV) output was experienced by the bulk power system in Southern California after a three-phase fault. Disturbance analysis indicates that instantaneous AC current caused inverter tripping. The projection of the root cause of AC overcurrent from the NERC report is that inverter current control is not tight. This letter provides a quantitative analysis on ac overcurrent and addresses the following questions: (i) what type of current controls may lead to ac overcurrent; and (ii) how controller parameters and grid strength influence ac overcurrent. Here, the letter provides frequency-domain analysis and time-domain simulation results of a grid-integrated inverter to illustrate the effect of control parameters and grid strength on ac overcurrent.

14 SOLAR ENERGY↗

Blackstart and Fault Ride-Through Capability of DFIG-Based Wind Turbines

Grid-forming wind turbines must be able to re-energize transmission branches, motor loads, unbalanced loads, and power electronics loads following a blackout. Further, they must ride through faults that can arise during restoration. To tackle these challenges, this paper sets forth a grid-forming control strategy for wind turbines using doubly-fed induction generators (DFIGs). In particular, a special set of feedforward control loops are engineered to mitigate the impacts of restoration transients as well as symmetrical and asymmetrical faults on the regulation of DFIG rotor currents and stator voltages. This paper also leverages two-axis anti-windup regulators to bound two-axis voltage and current commands within ratings. As a result, the controller performance is demonstrated via a high-fidelity simulation model of a notional wind-dominant grid.

17 WIND ENERGY↗

Intelligent fault diagnosis and failure management of flight control actuation systems

The real-time fault diagnosis and failure management (FDFM) of current operational and experimental dual tandem aircraft flight control system actuators was investigated. Dual tandem actuators were studied because of the active FDFM capability required to manage the redundancy of these actuators. The FDFM methods used on current dual tandem actuators were determined by examining six specific actuators. The FDFM capability on these six actuators was also evaluated. One approach for improving the FDFM capability on dual tandem actuators may be through the application of artificial intelligence (AI) technology. Existing AI approaches and applications of FDFM were examined and evaluated. Based on the general survey of AI FDFM approaches, the potential role of AI technology for real-time actuator FDFM was determined. Finally, FDFM and maintainability improvements for dual tandem actuators were recommended.

Bonnice, William F.↗

Hardware and software fault tolerance - A unified architectural approach

The loss of hardware fault tolerance which often arises when design diversity is used to improve the fault tolerance of computer software is considered analytically, and a unified design approach is proposed to avoid the problem. The fundamental theory of fault-tolerant (FT) architectures is reviewed; the current status of design-diversity software development is surveyed; and the FT-processor/attached-processor (FTP/AP) architecture developed by Lala et al. (1986) is described in detail and illustrated with diagrams. FTP/AP is shown to permit efficient implementation of N-version FT software while still tolerating random hardware failures with very high coverage; the reliability is found to be significantly higher than that of conventional majority-vote N-version software.

Lala, Jaynarayan H.↗

Implementation issues for a compact 6 degree of freedom force reflecting handcontroller with cueing of modes

Teleoperated control requires a master human interface device that can provide haptic input and output which reflect the responses of a slave robotic system. The effort reported in this paper addresses the design and prototyping of a six degree-of-freedom (DOF) Cartesian coordinate hand controller for this purpose. The device design recommended is an XYZ stage attached to a three-roll wrist which positions a flight-type handgrip. Six degrees of freedom are transduced and control brushless DC motor servo electronics similar in design to those used in computer controlled robotic manipulators. This general approach supports scaled force, velocity, and position feedback to aid an operator in achieving telepresence. The generality of the device and control system characteristics allow the use of inverse dynamics robotic control methodology to project slave robot system forces and inertias to the operator (in scaled form) and at the same time to reduce the apparent inertia of the robotic handcontroller itself. The current control design, which is not multiple fault tolerant, can be extended to make flight control or space use possible. The proposed handcontroller will have advantages in space-based applications where an operator must control several robot arms in a simultaneous and coordinated fashion. It will also have applications in intravehicular activities (within the Space Station) such as microgravity experiments in metallurgy and biological experiments that require isolation from the astronauts' environment. For ground applications, the handcontroller will be useful in underwater activities where the generality of the proposed handcontroller becomes an asset for operation of many different manipulator types. Also applications will emerge in the Military, Construction, and Maintenance/Manufacturing areas including ordnance handling, mine removal, NBC (Nuclear, Chemical, Biological) operations, control of vehicles, and operating strength and agility enhanced machines. Future avionics applications including advanced helicopter and aircraft control may also become important.

Jacobus, Heidi↗

Fundamentals of Digital Engineering: Designing for Reliability

The concept of designing for reliability will be introduced along with a brief overview of reliability, redundancy and traditional methods of fault tolerance is presented, as applied to current logic devices. The fundamentals of advanced circuit design and analysis techniques will be the primary focus. The introduction will cover the definitions of key device parameters and how analysis is used to prove circuit correctness. Basic design techniques such as synchronous vs asynchronous design, metastable state resolution time/arbiter design, and finite state machine structure/implementation will be reviewed. Advanced topics will be explored such as skew-tolerant circuit design, the use of triple-modular redundancy and circuit hazards, device transients and preventative circuit design, lock-up states in finite state machines generated by logic synthesizers, device transient characteristics, radiation mitigation techniques. worst-case analysis, the use of timing analyzer and simulators, and others. Case studies and lessons learned from spaceflight designs will be given as examples

Katz, R.↗

Controls and Health Management Technologies for Intelligent Aerospace Propulsion Systems

With the increased emphasis on aircraft safety, enhanced performance and affordability, and the need to reduce the environmental impact of aircraft, there are many new challenges being faced by the designers of aircraft propulsion systems. The Controls and Dynamics Technology Branch at NASA (National Aeronautics and Space Administration) Glenn Research Center (GRC) in Cleveland, Ohio, is leading and participating in various projects in partnership with other organizations within GRC and across NASA, the U.S. aerospace industry, and academia to develop advanced controls and health management technologies that will help meet these challenges through the concept of an Intelligent Engine. The key enabling technologies for an Intelligent Engine are the increased efficiencies of components through active control, advanced diagnostics and prognostics integrated with intelligent engine control to enhance component life, and distributed control with smart sensors and actuators in an adaptive fault tolerant architecture. This paper describes the current activities of the Controls and Dynamics Technology Branch in the areas of active component control and propulsion system intelligent control, and presents some recent analytical and experimental results in these areas.

Garg, Sanjay↗

NASA Glenn Research in Controls and Diagnostics for Intelligent Aerospace Propulsion Systems

With the increased emphasis on aircraft safety, enhanced performance and affordability, and the need to reduce the environmental impact of aircraft, there are many new challenges being faced by the designers of aircraft propulsion systems. Also the propulsion systems required to enable the NASA (National Aeronautics and Space Administration) Vision for Space Exploration in an affordable manner will need to have high reliability, safety and autonomous operation capability. The Controls and Dynamics Branch at NASA Glenn Research Center (GRC) in Cleveland, Ohio, is leading and participating in various projects in partnership with other organizations within GRC and across NASA, the U.S. aerospace industry, and academia to develop advanced controls and health management technologies that will help meet these challenges through the concept of Intelligent Propulsion Systems. The key enabling technologies for an Intelligent Propulsion System are the increased efficiencies of components through active control, advanced diagnostics and prognostics integrated with intelligent engine control to enhance operational reliability and component life, and distributed control with smart sensors and actuators in an adaptive fault tolerant architecture. This paper describes the current activities of the Controls and Dynamics Branch in the areas of active component control and propulsion system intelligent control, and presents some recent analytical and experimental results in these areas.

Source record↗