Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

A Kalman filter for a two-dimensional shallow-water model

A two-dimensional Kalman filter is described for data assimilation for making weather forecasts. The filter is regarded as superior to the optimal interpolation method because the filter determines the forecast error covariance matrix exactly instead of using an approximation. A generalized time step is defined which includes expressions for one time step of the forecast model, the error covariance matrix, the gain matrix, and the evolution of the covariance matrix. Subsequent time steps are achieved by quantifying the forecast variables or employing a linear extrapolation from a current variable set, assuming the forecast dynamics are linear. Calculations for the evolution of the error covariance matrix are banded, i.e., are performed only with the elements significantly different from zero. Experimental results are provided from an application of the filter to a shallow-water simulation covering a 6000 x 6000 km grid.

Parrish, D. F.↗

Adaptation of the chevron-notch beam fracture toughness method to specimens harvested from diesel particulate filters

In this paper, the apparent fracture toughness of a porous cordierite ceramic was estimated using a large specimen whose geometry was inspired by the ASTM-C1421-standardized chevron-notch beam. In this paper, using the same combination of experiment and analysis used to develop the standardized chevron-notch test for small, monolithic ceramic bend bars, an apparent fracture toughness of 0.6 and 0.9 MPa√m were estimated for an unaged and aged cordierite diesel particulate filter structure, respectively. Finally, the effectiveness and simplicity of this adapted specimen geometry and test method lends itself to the evaluation of (macroscopic) apparent fracture toughness of an entire porous-ceramic, diesel particulate filter structure.

36 MATERIALS SCIENCE↗

Real-Time Diagnosis of Faults Using a Bank of Kalman Filters

A new robust method of automated real-time diagnosis of faults in an aircraft engine or a similar complex system involves the use of a bank of Kalman filters. In order to be highly reliable, a diagnostic system must be designed to account for the numerous failure conditions that an aircraft engine may encounter in operation. The method achieves this objective though the utilization of multiple Kalman filters, each of which is uniquely designed based on a specific failure hypothesis. A fault-detection-and-isolation (FDI) system, developed based on this method, is able to isolate faults in sensors and actuators while detecting component faults (abrupt degradation in engine component performance). By affording a capability for real-time identification of minor faults before they grow into major ones, the method promises to enhance safety and reduce operating costs. The robustness of this method is further enhanced by incorporating information regarding the aging condition of an engine. In general, real-time fault diagnostic methods use the nominal performance of a "healthy" new engine as a reference condition in the diagnostic process. Such an approach does not account for gradual changes in performance associated with aging of an otherwise healthy engine. By incorporating information on gradual, aging-related changes, the new method makes it possible to retain at least some of the sensitivity and accuracy needed to detect incipient faults while preventing false alarms that could result from erroneous interpretation of symptoms of aging as symptoms of failures. The figure schematically depicts an FDI system according to the new method. The FDI system is integrated with an engine, from which it accepts two sets of input signals: sensor readings and actuator commands. Two main parts of the FDI system are a bank of Kalman filters and a subsystem that implements FDI decision rules. Each Kalman filter is designed to detect a specific sensor or actuator fault. When a sensor or actuator fault occurs, large estimation errors are generated by all filters except the one using the correct hypothesis. By monitoring the residual output of each filter, the specific fault that has occurred can be detected and isolated on the basis of the decision rules. A set of parameters that indicate the performance of the engine components is estimated by the "correct" Kalman filter for use in detecting component faults. To reduce the loss of diagnostic accuracy and sensitivity in the face of aging, the FDI system accepts information from a steady-state-condition-monitoring system. This information is used to update the Kalman filters and a data bank of trim values representative of the current aging condition.

Kobayashi, Takahisa↗

Monte Carlo turbulence simulation

The paper describes turbulence simulation experiments based on the principles of control system theory, that is, the construction of a system characterized by a system function such that upon exciting the system with prescribed noise processes the output of the system is a realization of a random processing the desired statistical attributes of turbulence. An experimental autocorrelation of Jimsphere measurements of wind velocity was approximated to simulate turbulent wind. From the approximate autocorrelation function, the required system function is obtained, and a discrete time system is designed. Another method of simulation is to solve the convolution integral by filter techniques. Other methods include discrete Fourier simulation and self-similar simulation.

Fichtl, G. H.↗

An all-purpose computer program for lidar simulations and reduction of lidar data

A general computer program was written for the dual purpose of simulating lidar returm signals and extracting H2O vapor and temperature (T) profiles from actual lidar returns. This program will be used to retrieve H2O vapor and T profiles from data obtained with the University of Maryland ground-based lidar systems. The program is designed to simulate and to analyze lidar returns from a monostatic system for two cases: when the output laser pulse is monochromatic, and when the pulse has a known wavelength spectrum. The simulation part of the program has several model H2O vapor, T, and aerosol profiles which can be combined to form different model atmospheres. The simulation program also permits the testing of different methods of numerical filtering to suppress noise, and testing the accuracy of different methods of numerical integration.

Braun, C.↗

Tunable coherent light filter for optical sensing and imaging

Systems and methods are provided for filtering coherent infrared light from a thermal background for protection of infrared (IR) imaging arrays and detection systems. A Michelson interferometer is used for coherent light filtering. In an implementation, a system includes a fixed mirror, a beam splitter, and a moving mirror which can be controlled translationally, as well as tip/tilt. The Michelson interferometer may be used as an imaging system. For imaging applications, a system may comprise a tunable array of micro-electromechanical systems (MEMS) mirrors. A mid-wave IR interferometer with electronic feedback and MEMS mirror array is provided.

Wasserman, David↗

A new nonlinear reconstruction method based on total variation regularization of neutron penumbral imaging

Neutron penumbral imaging is a significant diagnostic technique in laser-driven inertial confinement fusion experiment. It is very important to develop a new reconstruction method to improve the resolution of neutron penumbral imaging. A new nonlinear reconstruction method based on total variation (TV) regularization is proposed in this paper. A TV-norm is used as regularized term to construct a smoothing functional for penumbral image reconstruction in the new method, in this way, the problem of penumbral image reconstruction is transformed to the problem of a functional minimization. In addition, a fixed point iteration scheme is introduced to solve the problem of functional minimization. The numerical experimental results show that, compared to linear reconstruction method based on Wiener filter, the TV regularized nonlinear reconstruction method is beneficial to improve the quality of reconstructed image with better performance of noise smoothing and edge preserving. Meanwhile, it can also obtain the spatial resolution with 5 {mu}m which is higher than the Wiener method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Define and Quantify the Physics of Air Flow, Pressure Drop and Aerosol Collection in Nuclear Grade HEPA Filters

Objective: Develop a set of peer-review and verified analytical methods to adjust HEPA filter performance to different flow rates, temperatures and altitudes. Experimental testing will measure HEPA filter flow rate, pressure drop and efficiency to verify the analytical approach. Nuclear facilities utilize HEPA (High Efficiency Particulate Air) filters to purify air flow for workspace ventilation. However, the ASME AG-1 technical standard (Code on Nuclear Air and Gas Treatment) does not adequately describe air flow measurement units for HEPA filter systems. Specifically, the AG-1 standard does not differentiate between volumetric air flow in ACFM (actual cubic feet per minute)compared to mass flow measured in SCFM (standard cubic feet per minute). More importantly, the AG-1 standard has an overall deficiency for using HEPA filter devices at different air flow rates, temperatures, and altitudes. Technical Approach: The collection efficiency and pressure drops of 18 different HEPA filters will be measured over a range of flow rates, temperatures and altitudes. The experimental results will be compared to analytical scoping calculations. Three manufacturers have allocated six HEPA filters each for this effort. The 18 filters will be tested at two different flow rates, two different temperatures and two different altitudes. The 36 total tests will be conducted at two different facilities: the ATI Test facilities (Baltimore MD) and the Los Alamos National Laboratory (Los Alamos NM). The Radiation Protection RP-SVS group at Los Alamos has an aerosol wind tunnel that was originally designed to evaluate small air samplers. In 2010, modifications were started to convert the wind tunnel for HEPA filter testing. (Extensive changes were necessary for the required aerosol generators, HEPA test fixtures, temperature control devices and measurement capabilities.) To this date, none of these modification activities have been funded through a specific DOE or NNSA program. This is expected to require six months of time, after receipt of funding. Benefits: US DOE facilities that use HEPA filters will benefit from access to the new operational measurement methods. Uncertainty and guesswork will be removed from HEPA filter operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optical calculation of correlation filters for a robotic vision system

A method is presented for designing optical correlation filters based on measuring three intensity patterns: the Fourier transform of a filter object, a reference wave and the interference pattern produced by the sum of the object transform and the reference. The method can produce a filter that is well matched to both the object, its transforming optical system and the spatial light modulator used in the correlator input plane. A computer simulation was presented to demonstrate the approach for the special case of a conventional binary phase-only filter. The simulation produced a workable filter with a sharp correlation peak.

Knopp, Jerome↗

Amidoxime-Functionalized Macroporous Carbon Self-Refreshed Electrode Materials for Rapid and High-Capacity Removal of Heavy Metal from Water

Heavy metal pollution continues to be one of the most serious environmental problems which has attracted major global concern. Here, a rapid, high-capacity, yet economical strategy for deep cleaning of heavy metals ions in water is reported based on amidoxime-functionalized macroporous carbon electrode materials. The active sites of our material can be self-refreshed during the electrochemical removal process, which is different from traditional methods. The novel filter device in this work can purify contaminated water very rapidly (3000 L h –1 m –2 ), and can decrease heavy metal ion concentrations to below 5 ppb with a very short contact time (only 3 s). The original treatment efficiency of the device can be retained even after 1 week of continuous device operation. An extremely high removal capacity of over 2300 mg g –1 can be achieved with 2–3 orders of magnitude higher efficiency than that of surface adsorption-based commercial filters without any decay. Additionally, the cost of energy consumed in our method is lower than $6.67 × 10 –3 per ton of wastewater. We envision that this approach can be routinely applied for the rapid, efficient, and thorough removal of heavy metals from both point-of-use water and industrial wastewater.

36 MATERIALS SCIENCE↗

STATISTICAL ANALYSIS OF THE HEAVY NEUTRAL ATOMS MEASURED BY IBEX

We investigate the directional distribution of heavy neutral atoms in the heliosphere by using heavy neutral maps generated with the IBEX-Lo instrument over three years from 2009 to 2011. The interstellar neutral (ISN) O and Ne gas flow was found in the first-year heavy neutral map at 601 keV and its flow direction and temperature were studied. However, due to the low counting statistics, researchers have not treated the full sky maps in detail. The main goal of this study is to evaluate the statistical significance of each pixel in the heavy neutral maps to get a better understanding of the directional distribution of heavy neutral atoms in the heliosphere. Here, we examine three statistical analysis methods: the signal-to-noise filter, the confidence limit method, and the cluster analysis method. These methods allow us to exclude background from areas where the heavy neutral signal is statistically significant. These methods also allow the consistent detection of heavy neutral atom structures. The main emission feature expands toward lower longitude and higher latitude from the observational peak of the ISN O and Ne gas flow. We call this emission the extended tail. It may be an imprint of the secondary oxygen atoms generated by charge exchange between ISN hydrogen atoms and oxygen ions in the outer heliosheath.

74 ATOMIC AND MOLECULAR PHYSICS↗

Formulation and implementation of nonstationary adaptive estimation algorithm with applications to air-data reconstruction

The dynamics model and data sources used to perform air-data reconstruction are discussed, as well as the Kalman filter. The need for adaptive determination of the noise statistics of the process is indicated. The filter innovations are presented as a means of developing the adaptive criterion, which is based on the true mean and covariance of the filter innovations. A method for the numerical approximation of the mean and covariance of the filter innovations is presented. The algorithm as developed is applied to air-data reconstruction for the space shuttle, and data obtained from the third landing are presented. To verify the performance of the adaptive algorithm, the reconstruction is also performed using a constant covariance Kalman filter. The results of the reconstructions are compared, and the adaptive algorithm exhibits better performance.

Whitmore, S. A.↗

Formulation and implementation of nonstationary adaptive estimation algorithm with applications to air-data reconstruction

The dynamics model and data sources used to perform air-data reconstruction are discussed, as well as the Kalman filter. The need for adaptive determination of the noise statistics of the process is indicated. The filter innovations are presented as a means of developing the adaptive criterion, which is based on the true mean and covariance of the filter innovations. A method for the numerical approximation of the mean and covariance of the filter innovations is presented. The algorithm as developed is applied to air-data reconstruction for the Space Shuttle, and data obtained from the third landing are presented. To verify the performance of the adaptive algorithm, the reconstruction is also performed using a constant covariance Kalman filter. The results of the reconstructions are compared, and the adaptive algorithm exhibits better performance.

Whitmore, S. A.↗

Monolith filter apparatus and membrane apparatus, and method using same

A filtration apparatus that separates a liquid feedstock mixed with a gas into filtrate and retentate, the apparatus including at least one filtration device comprised of at least one monolith segment of porous material that defines a plurality of passageways extending longitudinally from a feed face of the structure to a retentate end face. The filtration device contains at least one filtrate conduit within it for carrying filtrate toward a filtrate collection zone, the filtrate conduit providing a path of lower flow resistance than that of alternative flow paths through the porous material of the device. The filtration device can also be utilized as a membrane support for a device for microfiltration, ultrafiltration, nanofiltration, reverse osmosis, or pervaporation. Also disclosed is a method for using such a filtration apparatus.

47 OTHER INSTRUMENTATION↗

Higher-order dispersion compensating pulse shaper via amplitude spectral filtering and nonlinear phase accumulation

A method of pulse shaping using spectral filtering, positive chirp, and self-phase modulation to control the accumulated higher-order phase terms of the spectral phase. This pulse shaping method has particular advantage in fiber chirped pulse amplification (FCPA) systems, where there are two effects: (1) an offsetting of the fourth order phase via nonlinear phase accumulation, allowing for a higher Strehl ratio (i.e., a cleaner pulse), higher peak power pulse and (2) enabling power scaling to higher pulse energies without the increased nonlinear phase accumulation leading to pulse breakup. This technique can be used both in a passive system with no amplification to clean up an existing pulse, and in an amplifier system to enable higher performance operation (shorter pulses, cleaner pulses, higher energy pulses).

Domingue, Scott R.↗

SU-E-T-61: A Practical Process for Fabricating Passive Scatter Proton Beam Modulation Compensation Filters Using 3D Printing

Purpose: The purpose of this project was to devise a practical fabrication process for passive scatter proton beam compensation filters (CF) that is competitive in time, cost and effort using 3D printing. Methods: DICOM compensator filter files for a proton beam were generated by our Eclipse (Varian, Inc.) treatment planning system. The compensator thickness specifications were extracted with in-house software written in Matlab (MathWorks, Inc.) code and written to a text file which could be read by the Rhinoceros 5, computer-aided design (CAD) package (Robert McNeel and Associates), which subsequently generated a smoothed model in a STereoLithographic also known as a Standard Tesselation Language file (STL). The model in the STL file was subsequently refined using Netfabb software and then converted to printing instructions using Cura. version 15.02.1. for our 3D printer. The Airwolf3D, model HD2x, fused filament fabrication (FFF) 3D printer (Airwolf3D.com) was used for our fabrication system with a print speed of 150mm per second. It can print in over 22 different plastic filament materials in a build volume of 11” x 8” x 12”. We choose ABS plastic to print the 3D model of the imprint for our CFs. Results: Prints of the CF could be performed at a print speed of 70mm per second. The time to print the 3D topology for the CF for the 14 cm diameter snout of our Mevion 250 proton accelerator was less than 3 hours. The printed model is intended to subsequently be used as a mold to imprint a molten wax cylindrical to form the compensation after cooling. The whole process should be performed for a typical 3 beam treatment plan within a day. Conclusion: Use of 3D printing is practical and can be used to print a 3D model of a CF within a few hours.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗