Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Operation of the Airmodus A11 nano Condensation Nucleus Counter at various inlet pressures and various operation temperatures, and design of a new inlet system

Measuring sub-3 nm particles outside of controlled laboratory conditions is a challenging task, as many of the instruments are operated at their limits and are subject to changing ambient conditions. In this study, we advance the current understanding of the operation of the Airmodus A11 nano Condensation Nucleus Counter (nCNC), which consists of an A10 Particle Size Magnifier (PSM) and an A20 Condensation Particle Counter (CPC). The effect of the inlet line pressure on the measured particle concentration was measured, and two separate regions inside the A10, where supersaturation of working fluid can take place, were identified. The possibility of varying the lower cut-off diameter of the nCNC was investigated; by scanning the growth tube temperature, the range of the lower cut-off was extended from 1–2.5 to 1–6 nm. Here we present a new inlet system, which allows automated measurement of the background concentration of homogeneously nucleated droplets, minimizes the diffusion losses in the sampling line and is equipped with an electrostatic filter to remove ions smaller than approximately 4.5 nm. Lastly, our view of the guidelines for the optimal use of the Airmodus nCNC is provided.

54 ENVIRONMENTAL SCIENCES↗

Studies of Front-End Electronics for High-Precision Timing Measurements with LGADs [Poster]

In Time-of-Arrival (ToA) measurements, simulations can be used to optimize precision detection and implementation methods of front-end electronics. The simulation tested in this project takes the response of a filter (in the s-domain) from a noisy input current signal from the detector, an LGAD (Low-Gain Avalanche Diode), and uses a threshold to determine the ToA value for the signal. Measuring the ToA values for a large sample of events and comparing them to a reference statistically produces the timing precision of the simulation. Here, the sub-algorithm to model LGAD events with piecewise linear (PWL) approximations (for more efficient Laplace transforms) was optimized. Using the Fourier Discrete Cosine Transform, 25 points could be selected to describe the primary behavior of the signal. Results showed that timing precision is on par with previous methods. We also found that the new algorithm is faster and equally consistent in producing accurate PWL approximations. Testi ng with larger samples is required to fully verify the new algorithm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultrathin amorphous carbon films synthesized by filtered cathodic vacuum arc used as protective overcoats of heat-assisted magnetic recording heads

Despite numerous investigations of amorphous carbon (a-C) films, a comprehensive study of the feasibility and optimization of sub-5-nm-thick a-C films deposited onto the write pole of heat-assisted magnetic recording (HAMR) heads is lacking. The main objective of this study was to identify the role of pulse substrate bias voltage and C+ ion incidence angle on the structure and thickness of 1–4-nm-thick a-C films deposited by a rather new thin-film deposition method, known as filtered cathodic vacuum arc (FCVA). The cross-sectional structure of a-C films synthesized under various FCVA conditions was examined by high-resolution transmission electron microscopy (HRTEM), scanning transmission electron microscopy (STEM), and electron energy loss spectroscopy (EELS). It was found that film growth under process conditions of low-to-intermediate substrate bias voltage (in the range of -25 to -100 V), low ion incidence angle (10°), very short deposition time (6 s), and fixed other deposition parameters (65% duty cycle of substrate pulse biasing and 1.48 × 10 19 ions/m 2 ·s ion flux) yields a-C films of thickness ≤4 nm characterized by a significant content (~50–60 at%) of tetrahedral ( sp 3 ) carbon atom hybridization. A threshold where sp 3 hybridization is greatly reduced due to limited film growth was determined from the HRTEM/STEM and EELS measurements. The results of this study demonstrate the viability of FCVA to produce extremely thin and uniform protective a-C films with relatively high sp 3 contents for HAMR heads.

Science & Technology - Other Topics↗

MO-PIS-Exhibit Hall-01: Imaging: CT Dose Optimization Technologies I

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The imaging topic this year is CT scanner dose optimization capabilities. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Dose Optimization Capabilities of GE Computed Tomography Scanners Presentation Time: 11:15 – 11:45 AM GE Healthcare is dedicated to the delivery of high quality clinical images through the development of technologies, which optimize the application of ionizing radiation. In computed tomography, dose management solutions fall into four categories: employs projection data and statistical modeling to decrease noise in the reconstructed image - creating an opportunity for mA reduction in the acquisition of diagnostic images. Veo represents true Model Based Iterative Reconstruction (MBiR). Using high-level algorithms in tandem with advanced computing power, Veo enables lower pixel noise standard deviation and improved spatial resolution within a single image. Advanced Adaptive Image Filters allow for maintenance of spatial resolution while reducing image noise. Examples of adaptive image space filters include Neuro 3-D filters and Cardiac Noise Reduction Filters. AutomA adjusts mA along the z-axis and is the CT equivalent of auto exposure control in conventional x-ray systems. Dynamic Z-axis Tracking offers an additional opportunity for dose reduction in helical acquisitions while SmartTrack Z-axis Tracking serves to ensure beam, collimator and detector alignment during tube rotation. SmartmA provides angular mA modulation. ECG Helical Modulation reduces mA during the systolic phase of the heart cycle. SmartBeam optimization uses bowtie beam-shaping hardware and software to filter off-axis x-rays - minimizing dose and reducing x-ray scatter. The DICOM Radiation Dose Structured Report (RDSR) generates a dose report at the conclusion of every examination. Dose Check preemptively notifies CT operators when scan parameters exceed user-defined dose thresholds. DoseWatch is an information technology application providing vendor-agnostic dose tracking and analysis for CT (and all other diagnostic x-ray modalities) SnapShot Pulse improves coronary CTA dose management. VolumeShuttle uses two acquisitions to increase coverage, decrease dose, and conserve on contrast administration. Color-Coding for Kids applies the Broselow-Luten Pediatric System to facilitate pediatric emergency care and reduce medical errors. FeatherLight achieves dose optimization through pediatric procedure-based protocols. Adventure Series scanners provide a child-friendly imaging environment promoting patient cooperation with resultant reduction in retakes and patient motion. Philips CT Dose Optimization Tools and Advanced Reconstruction Presentation Time: 11:45 ‘ 12:15 PM The first part of the talk will cover “Dose Reduction and Dose Optimization Technologies” present in Philips CT Scanners. The main Technologies to be presented include: DoseRight and tube current modulation (DoseRight, Z-DOM, 3D-DOM, DoseRight Cardiac) Special acquisition modes Beam filtration and beam shapers Eclipse collimator and ClearRay collimator NanoPanel detector DoseRight will cover automatic tube current selection that automatically adjusts the dose for the individual patient. The presentation will explore the modulation techniques currently employed in Philips CT scanners and will include the algorithmic concepts as well as illustrative examples. Modulation and current selection technologies to be covered include the Automatic Current Selection component of DoseRight, ZDOM longitudinal dose modulation, 3D-DOM (combination of longitudinal and rotational dose modulation), Cardiac Dose right (an ECG based dose modulation scheme), and the DoseRight Index (DRI) IQ index. The special acquisition modes covers acquisition techniques such as prospective gating that is designed to reduce exposure to the patient through the Cardiac Step and Shoot scan mode. This mode can substitute the much higher dose retrospective scan modes for certain types of cardiac imaging. The beam filtration and beam shaper portion will discuss the variety of filtration and beam shaping configurations available on Philips scanners. This topic includes the x-ray beam characteristics, tube filtration as well as dose compensator characteristics. The Eclipse collimator, ClearRay collimator and the NanoPanel detector portion will discuss additional technologies specific to wide coverage CT that address some of the unique challenges encountered and techniques employed to optimize image quality and optimize dose utilization. The Eclipse collimator reduces extraneous exposure by actively blocking the radiation tails at either end of helical scans that do not contribute to the image generation. The ClearRay collimator and the NanoPanel detector optimize the quality of the signal that reaches the detectors by addressing the increased scattered radiation present in wide coverage and the NanoPanel detector adds superior electronic noise characteristics valuable when imaging at a low dose level. The second part of the talk will present “Advanced Reconstruction Technologies” currently available on Philips CT Scanners. The talk will cover filtered back projection (FBP), iDose4 and Iterative Model Reconstruction (IMR). Each reconstruction method will include a discussion of the algorithm as well as similarities and differences between the algorithms. Examples illustrating the merits of each algorithm will be presented, and techniques and metrics to characterize the performance of each type of algorithm will be presented. The Filtered Back projection portion will discuss and provide a brief summary of relevant standard image reconstruction techniques in common use, and discuss the common tradeoffs when using the FBP algorithm. The iDose4 portion will present the algorithms used for iDose4 as well the different levels. The meaning of different levels of iDose4 available will be presented and quantified. Guidelines for selection iDose4 parameters based on the imaging need will be explained. The different image quality goals available with iDose4 and specifically how iDose4 enables noise reduction, spatial resolution improvement or both will be explained. The approaches to leveraging the benefits of iDose4 such as improved spatial resolution, decreased noise, and artifact prevention will be described and quantified; and measurements and metrics behind the improvements will be presented. The image quality benefits in specific imaging situations as well as how to best combine the technology with other dose reduction strategies to ensure the best image quality at a given dose level will be presented. Insight into the IMR algorithm as well as contrast to the iDose4 techniques and performance characteristics will be discussed. Metrics and techniques for characterizing this class of algorithm and IQ performance will be presented. The image quality benefits and the dose reduction capabilities of IMR will be explored. Illustrative examples of the noise reduction, spatial resolution improvement, and low contrast detectability improvements of the reconstruction method will be presented: clinical cases and phantom measurements demonstrating the benefits of IMR in the areas of low dose imaging, spatial resolution and low contrast resolution are discussed and the technical details behind the measurements will be presented compared to both iDose4 and traditional filtered back projection (FBP)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculation of Higher Eigenpairs of the Transport Equation Using IRAM Based on Domain Decomposition

The higher eigenpairs of the neutron transport (or diffusion) equation are useful in core flux distribution reconstruction, transient analysis, stability analysis, and loading pattern optimization. There are various methods for the calculation of higher eigenpairs, such as the power iteration method with filtering technique, the Generalized Modified Power Method (GMPM), the power iteration method with innovative boundary conditions for symmetric cores, and Krylov subspace methods. In regard to Krylov subspace methods, the Implicitly Restarted Arnoldi Method (IRAM) and ORTHOMIN were implemented to calculate higher eigenpairs for both transport and diffusion equations. In Warsa's work, however, there was a significant drawback that problems with energy upscatter could not be treated efficiently. In Modak's work, the mode to which his method was likely to converge depended on the shape of initial guess flux, and only one mode could be computed each time, making it impractical for real use. Furthermore, the computational burden for higher eigenpairs is generally much larger than for only the first eigenpair, especially for neutron transport equations. Therefore, the implementation of parallel computation for higher eigenpairs is essential to improve the efficiency, and no such work has been reported in literature so far. In this summary, we propose an innovative method to calculate higher eigenpairs of the neutron transport equation based on high performance computation. In this method, 2D Matrix Method of Characteristic (MMOC) is used to discretize the neutron transport equation; IRAM is used to evaluate higher eigenpairs; spatial domain decomposition is used to realize parallel computation. The highlight of this method is using the MGMD PGMRES (Multi-Group and Multi-Domain coupled Parallel Generalized Minimal Residual Method) algorithm to simultaneously accelerate the upscatter iterations and the inner interface angular fluxes iterations, avoiding the drawback in Warsa's method and the efficiency problem of conventional Jacobi iteration. To the best of our knowledge, our work represents the first application of IRAM based on domain decomposition for higher eigenpairs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantifying and reducing model-form uncertainties in Reynolds-averaged Navier–Stokes simulations: A data-driven, physics-informed Bayesian approach

Despite their well-known limitations, Reynolds-Averaged Navier–Stokes (RANS) models are still the workhorse tools for turbulent flow simulations in today's engineering analysis, design and optimization. While the predictive capability of RANS models depends on many factors, for many practical flows the turbulence models are by far the largest source of uncertainty. As RANS models are used in the design and safety evaluation of many mission-critical systems such as airplanes and nuclear power plants, quantifying their model-form uncertainties has significant implications in enabling risk-informed decision-making. In this work we develop a data-driven, physics-informed Bayesian framework for quantifying model-form uncertainties in RANS simulations. Uncertainties are introduced directly to the Reynolds stresses and are represented with compact parameterization accounting for empirical prior knowledge and physical constraints (e.g., realizability, smoothness, and symmetry). An iterative ensemble Kalman method is used to assimilate the prior knowledge and observation data in a Bayesian framework, and to propagate them to posterior distributions of velocities and other Quantities of Interest (QoIs). We use two representative cases, the flow over periodic hills and the flow in a square duct, to evaluate the performance of the proposed framework. Both cases are challenging for standard RANS turbulence models. Simulation results suggest that, even with very sparse observations, the obtained posterior mean velocities and other QoIs have significantly better agreement with the benchmark data compared to the baseline results. At most locations the posterior distribution adequately captures the true model error within the developed model form uncertainty bounds. The framework is a major improvement over existing black-box, physics-neutral methods for model-form uncertainty quantification, where prior knowledge and details of the models are not exploited. This approach has potential implications in many fields in which the governing equations are well understood but the model uncertainty comes from unresolved physical processes. - Highlights: • Proposed a physics–informed framework to quantify uncertainty in RANS simulations. • Framework incorporates physical prior knowledge and observation data. • Based on a rigorous Bayesian framework yet fully utilizes physical model. • Applicable for many complex physical systems beyond turbulent flows.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Randomized Adiabatic Quantum Linear Solver Algorithm with Optimal Complexity Scaling and Detailed Running Costs

Solving linear systems of equations is a fundamental problem with a wide variety of applications across many fields of science, and there is increasing effort to develop quantum linear solver algorithms. Subaşı et al. [Phys. Rev. Lett. 122, 060504 (2019)] proposed a randomized algorithm inspired by adiabatic quantum computing, based on a sequence of random Hamiltonian simulation steps, with suboptimal scaling in the condition number 𝜅 of the linear system and the target error 𝜖. Here we go beyond these results in several ways. Firstly, using filtering [Lin and Tong, Quantum 4, 361 (2020)] and Poissonization techniques [Cunningham and Roland, ArXiv:2406.03972 (2024)], the algorithm complexity is improved to the optimal scaling 𝑂⁡(𝜅⁢log (1/𝜖))—an exponential improvement in 𝜖, and a shaving of a log 𝜅 scaling factor in 𝜅. Secondly, the algorithm is further modified to achieve constant factor improvements, which are vital as we progress towards hardware implementations on fault-tolerant devices. We introduce a cheaper randomized walk operator method replacing Hamiltonian simulation—which also removes the need for potentially challenging classical precomputations; randomized routines are sampled over optimized random variables; circuit constructions are improved. We obtain a closed formula rigorously upper bounding the expected number of times one needs to apply a block-encoding of the linear system matrix to output a quantum state encoding the solution to the linear system. The upper bound is 837⁢𝜅 at 𝜖 = 10 −10 for Hermitian matrices.

97 MATHEMATICS AND COMPUTING↗

The effect of head size/shape, miscentering, and bowtie filter on peak patient tissue doses from modern brain perfusion 256-slice CT: How can we minimize the risk for deterministic effects?

Purpose: To determine patient-specific absorbed peak doses to skin, eye lens, brain parenchyma, and cranial red bone marrow (RBM) of adult individuals subjected to low-dose brain perfusion CT studies on a 256-slice CT scanner, and investigate the effect of patient head size/shape, head position during the examination and bowtie filter used on peak tissue doses. Methods: The peak doses to eye lens, skin, brain, and RBM were measured in 106 individual-specific adult head phantoms subjected to the standard low-dose brain perfusion CT on a 256-slice CT scanner using a novel Monte Carlo simulation software dedicated for patient CT dosimetry. Peak tissue doses were compared to corresponding thresholds for induction of cataract, erythema, cerebrovascular disease, and depression of hematopoiesis, respectively. The effects of patient head size/shape, head position during acquisition and bowtie filter used on resulting peak patient tissue doses were investigated. The effect of eye-lens position in the scanned head region was also investigated. The effect of miscentering and use of narrow bowtie filter on image quality was assessed. Results: The mean peak doses to eye lens, skin, brain, and RBM were found to be 124, 120, 95, and 163 mGy, respectively. The effect of patient head size and shape on peak tissue doses was found to be minimal since maximum differences were less than 7%. Patient head miscentering and bowtie filter selection were found to have a considerable effect on peak tissue doses. The peak eye-lens dose saving achieved by elevating head by 4 cm with respect to isocenter and using a narrow wedge filter was found to approach 50%. When the eye lies outside of the primarily irradiated head region, the dose to eye lens was found to drop to less than 20% of the corresponding dose measured when the eye lens was located in the middle of the x-ray beam. Positioning head phantom off-isocenter by 4 cm and employing a narrow wedge filter results in a moderate reduction of signal-to-noise ratio mainly to the peripheral region of the phantom. Conclusions: Despite typical peak doses to skin, eye lens, brain, and RBM from the standard low-dose brain perfusion 256-slice CT protocol are well below the corresponding thresholds for the induction of erythema, cataract, cerebrovascular disease, and depression of hematopoiesis, respectively, every effort should be made toward optimization of the procedure and minimization of dose received by these tissues. The current study provides evidence that the use of the narrower bowtie filter available may considerably reduce peak absorbed dose to all above radiosensitive tissues with minimal deterioration in image quality. Considerable reduction in peak eye-lens dose may also be achieved by positioning patient head center a few centimeters above isocenter during the exposure.

60 APPLIED LIFE SCIENCES↗

Locality-Driven Dynamic GPU Cache Bypassing

This paper presents novel cache optimizations for massively parallel, throughput-oriented architectures like GPUs. Based on the reuse characteristics of GPU workloads, we propose a design that integrates such efficient locality filtering capability into the decoupled tag store of the existing L1 D-cache through simple and cost-effective hardware extensions.

architecture optimization↗

Regularized deconvolution method for turbulent combustion modeling

The modeling of filtered chemical source terms in large-eddy simulation (LES) of turbulent reacting flows remains a challenge. Deconvolution methods are an attractive technique for representing these unclosed terms. With this technique, filtered scalars are reconstructed through deconvolution. The chemical source terms that are computed directly from the deconvolved scalars are filtered explicitly to represent the turbulence-chemistry interaction. However, the approximate deconvolution method (ADM), frequently employed for non-reacting flows, exhibits shortcomings for reacting scalars. This is because ADM does not ensure essential conservation and boundedness conditions. So to address this issue, we propose a regularized deconvolution method (RDM) based on an optimization procedure. We conduct a priori and a posteriori analyses to examine RDM as a closure in LES. These investigations are performed in the context of explicit filtering. By showing that RDM is accurate and stable with respect to both the filter width and time, we conclude that the new deconvolution method shows promise in application to combustion LES.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visible spectroscopy diagnostics for tungsten source assessment in the WEST tokamak: First measurements

The present work concerns the measurements obtained with the Tungsten (W) Environment in Steady-state Tokamak (WEST) visible spectroscopy system during the first experimental campaign. This system has been developed in the framework of the WEST project that equipped the existing Tore Supra device with a tungsten divertor in order to test actively cooled tungsten Plasma Facing Components (PFC) in view of preparing for ITER operation. The goal of this diagnostic is to measure the PFC sources and the deuterium recycling with spectral, spatial, and temporal resolution adapted to the predicted power deposition profiles on the objects observed. Three kinds of PFCs are monitored: the Ion Cyclotron Resonance Heating (ICRH) antenna and Low Hybrid Current Drive (LHCD) launcher W limiters; one of the 6 W inner bumpers; and the upper and lower W divertors. Large-aperture in-vessel actively cooled optical systems (f-number ~ 3) were installed for each view and connected to optical fibres. A total of 240 optical fibers can be distributed on various detection systems including a fast response-time, multi-channel, filtered photodetector-based “Filterscope” system, developed by Oak Ridge National Laboratory (USA) as well as grating spectrometers optimized for multi-sightline analysis. The first WEST experimental campaign conducted in 2017 has been dedicated to plasma start-up development during which the visible spectroscopy system has provided crucial information related to the impurity content first and then impurity sources. The diagnostic setup for that first experimental campaign was limited to the inner bumper and outer limiters but was sufficient to demonstrate that the optical setup was in accordance with the specifications. The radiance calibration procedure allowed us to estimate fluxes from the main limiter of about 8 × 10 18 atoms/(s m 2 ) and to show a first W source radial profile along the outboard limiter.

Meyer, O.↗

THE CLUSTER LENSING AND SUPERNOVA SURVEY WITH HUBBLE: AN OVERVIEW

The Cluster Lensing And Supernova survey with Hubble (CLASH) is a 524-orbit Multi-Cycle Treasury Program to use the gravitational lensing properties of 25 galaxy clusters to accurately constrain their mass distributions. The survey, described in detail in this paper, will definitively establish the degree of concentration of dark matter in the cluster cores, a key prediction of structure formation models. The CLASH cluster sample is larger and less biased than current samples of space-based imaging studies of clusters to similar depth, as we have minimized lensing-based selection that favors systems with overly dense cores. Specifically, 20 CLASH clusters are solely X-ray selected. The X-ray-selected clusters are massive (kT > 5 keV) and, in most cases, dynamically relaxed. Five additional clusters are included for their lensing strength ({theta}{sub Ein} > 35'' at z{sub s} = 2) to optimize the likelihood of finding highly magnified high-z (z > 7) galaxies. A total of 16 broadband filters, spanning the near-UV to near-IR, are employed for each 20-orbit campaign on each cluster. These data are used to measure precise ({sigma}{sub z} {approx} 0.02(1 + z)) photometric redshifts for newly discovered arcs. Observations of each cluster are spread over eight epochs to enable a search for Type Ia supernovae at z > 1 to improve constraints on the time dependence of the dark energy equation of state and the evolution of supernovae. We present newly re-derived X-ray luminosities, temperatures, and Fe abundances for the CLASH clusters as well as a representative source list for MACS1149.6+2223 (z 0.544).

79 ASTRONOMY AND ASTROPHYSICS↗

Training NuGraph2 for ICARUS

This presentation describes the process of training NuGraph2, a Graphical Neural Network for event reconstruction, on simulated ICARUS neutrino event data. This began with an investigation into filtering ICARUS spacepoint data. Then NuGraph2 was repeatedly trained on three event samples, which were used for finding optimized machine-learning parameters and to find and fix the causes of several crashes in NuGraph2 s preprocessing and training scripts.

43 PARTICLE ACCELERATORS↗

Interfacial structure in Telluride-based thermoelectric materials.

Chalcogenide compounds based on the rocksalt and tetradymite structures possess good thermoelectric properties and are widely used in a variety of thermoelectric devices. Examples include PbTe and AgSbTe2, which have the rocksalt structure, and Bi2Te3, Bi2Se3, and Sb2Te3, which fall within the broad tetradymite-class of structures. These materials are also of interest for thermoelectric nanocomposites, where the aim is to improve thermoelectric energy conversion efficiency by harnessing interfacial scattering processes (e.g., reducing the thermal conductivity by phonon scattering or enhancing the Seebeck coefficient by energy filtering). Understanding the phase stability and microstructural evolution within such materials is key to designing processing approaches for optimal thermoelectric performance and to predicting the long-term nanostructural stability of the materials. In this presentation, we discuss our work investigating relationships between interfacial structure and formation mechanisms in several telluride-based thermoelectric materials. We begin with a discussion of interfacial coherency and its special aspects at interfaces in telluride compounds based on the rocksalt and tetradymite structures. We compare perfectly coherent interfaces, such as the Bi2Te3 (0001) twin, with semi-coherent, misfitting interfaces. We next discuss the formal crystallographic analysis of interfacial defects in these systems and then apply this methodology to high resolution transmission electron microscopy (HRTEM) observations of interfaces in the AgSbTe2/Sb2Te3 and PbTe/Sb2Te3 systems, focusing on interfaces vicinal to {l_brace}111{r_brace}/{l_brace}0001{r_brace}. Through this analysis, we identify a defect that can accomplish the rocksalt-to-tetradymite phase transformation through diffusive-glide motion along the interface.

36 MATERIALS SCIENCE↗

Physical conditions for UO formation in laser-produced uranium plumes

Laser-induced plasma spectroscopy is a powerful method for elemental detection and analysis, however the broadening and merging of densely packed spectral lines can make it especially challenging for studying high-Z elements such as uranium and other actinides. In order to understand the processes occurring in laser-induced plasma, it is necessary to evaluate the variation of its thermodynamic parameters. We performed spatiotemporal diagnostics of uranium species in plasma plumes produced by nanosecond near-infrared laser pulses in low- pressure environment. Spatially- and temporally-resolved emission spectroscopy experiments are supported by modeling of uranium emission and its persistence in the plume. Saha-Eggert equation as well as Boltzmann diagrams generated from numerous U I transitions are used to infer temperature. We report the rst measurements of uranium Stark broadening parameters for U I 499.01 nm and U II 500.82 nm transitions. The Stark widths of selected U transitions were measured by comparing their linewidths with the broadening of O I 777.19 nm line. Electron density was found to be on the order of 1016 cm??3, while the temperature was found to be in the range of 3000{8000 K. In addition to enhancing the fundamental understanding of high-Z plasmas under reduced-pressure environments, the knowledge of Stark broadening parameters could improve modeling capabilities and analytical performance of techniques that rely on emission plasma spectroscopy.

(140.3440) Laser-induced breakdown, (280.4788) Opt↗

Weak signal detection in hyperspectral imagery using sparse matrix transform (SMT) covariance estimation

Many detection algorithms in hyperspectral image analysis, from well-characterized gaseous and solid targets to deliberately uncharacterized anomalies and anomlous changes, depend on accurately estimating the covariance matrix of the background. In practice, the background covariance is estimated from samples in the image, and imprecision in this estimate can lead to a loss of detection power. In this paper, we describe the sparse matrix transform (SMT) and investigate its utility for estimating the covariance matrix from a limited number of samples. The SMT is formed by a product of pairwise coordinate (Givens) rotations, which can be efficiently estimated using greedy optimization. Experiments on hyperspectral data show that the estimate accurately reproduces even small eigenvalues and eigenvectors. In particular, we find that using the SMT to estimate the covariance matrix used in the adaptive matched filter leads to consistently higher signal-to-noise ratios.

97 MATHEMATICS AND COMPUTING↗