Search NASA⌕ Search

SEARCH · Search NASA

Results for “filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

System for outputting a spectrum of light of a scene having optical detectors to receive light of different spectral transmittance from respective filters

Technologies pertaining to a compressive sensing snapshot spectrometer are described herein. Light is focused through an array of filters onto an array of optical detectors by way of an optical objective. Each detector in the array receives light from a single respective filter in the filters. Each filter in the filters has a spectral transmittance function that overlaps a spectral transmittance function of at least one other filter. A compressive sensing algorithm is executed over outputs of the detectors based upon the known spectral transmittance functions of the filters. Based upon the execution of the compressive sensing algorithm, intensity values of the light are identified for a number of spectral bins that is greater than a number of detectors in the array.

Shields, Eric A.↗

Group Lifting Structures For Multirate Filter Banks, I: Uniqueness Of Lifting Factorizations

This paper studies two-channel finite impulse response (FIR) perfect reconstruction filter banks. The connection between filter banks and wavelet transforms is well-known and will not be treated here. Figure 1 depicts the polyphase-with-advance representation of a filter bank [6]. A lifting factorization, is a factorization of polyphase matrices into upper and lower triangular lifting matrices. The existence of such decompositions via the Euclidean algorithm was shown for general FIR perfect reconstruction filter banks in [9] and was subsequently refined for linear phase filter banks in [10], [6]. These latter works were motivated by the ISO JPEG 2000 image coding standard [11], [12], [10], which specifies whole-sample symmetric (WS, or FIR type 1 linear phase) filter banks, as in Figure 2(a), in terms of half-sample symmetric (RS, or FIR type 2) lifting filters.

42 ENGINEERING↗

Simple through-plane spatial filter for 2D MRI projections

A simple spatial filter for 2D projection MR imaging is introduced. It works in the third (unresolved) direction to eliminate uniform or slowly varying interfering background signals. A constant amplitude gradient pulse in the unresolved direction is applied at the same time as the usual phase encode gradient during 2D acquisition. The filter is demonstrated for root imaging in soil, where background soil water signals can be troublesome. The filter suppresses the soil water signal while preserving the desired signal of plant roots. Fundamental to the operation of the filter is that the roots are sparse in the image domain, meaning there are relatively few pixels with multiple roots present. Here, the performance of the through-plane filter is demonstrated and compares favorably to more conventional in-plane spatial filtering.

47 OTHER INSTRUMENTATION↗

Investigating the fate of saxitoxins in biologically active water treatment plant filters

The saxitoxins are potent neurotoxins, which can be produced by freshwater cyanobacteria. This study assessed the fate of five saxitoxins variants through biologically active laboratory filters containing media sourced from the filters beds of two water treatment plants (WTPs). Decreases in the concentration of the less toxic variants coincided with increases in the concentrations of the more toxic variants through the filters containing anthracite sourced from two different WTPs. No changes in toxin concentrations were evident through parallel filters containing sand. The results strongly suggest that organisms within the biofilm of the anthracite filters possessed the ability to biotransform the saxitoxins variants, which has important implications for drinking water treatment, particularly since this has the potential to increase the toxicity of the filtered water.

01 COAL, LIGNITE, AND PEAT↗

The Need for Anticoagulation Following Inferior Vena Cava Filter Placement: Systematic Review

Purpose. To perform a systemic review to determine the effect of anticoagulation on the rates of venous thromboembolism (pulmonary embolus, deep venous thrombosis, inferior vena cava (IVC) filter thrombosis) following placement of an IVC filter. Methods. A comprehensive computerized literature search was performed to identify relevant articles. Data were abstracted by two reviewers. Studies were included if it could be determined whether or not subjects received anticoagulation following filter placement, and if follow-up data were presented. A meta-analysis of patients from all included studies was performed. A total of 14 articles were included in the final analysis, but the data from only nine articles could be used in the meta-analysis; five studies were excluded because they did not present raw data which could be analyzed in the meta-analysis. A total of 1,369 subjects were included in the final meta-analysis. Results. The summary odds ratio for the effect of anticoagulation on venous thromboembolism rates following filter deployment was 0.639 (95% CI 0.351 to 1.159, p = 0.141). There was significant heterogeneity in the results from different studies [Q statistic of 15.95 (p = 0.043)]. Following the meta-analysis, there was a trend toward decreased venous thromboembolism rates in patients with post-filter anticoagulation (12.3% vs. 15.8%), but the result failed to reach statistical significance. Conclusion. Inferior vena cava filters can be placed in patients who cannot receive concomitant anticoagulation without placing them at significantly higher risk of development of venous thromboembolism.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

OptEase and TrapEase Vena Cava Filters: A Single-Center Experience in 258 Patients

We aimed to evaluate the efficacy and safety of the OptEase and TrapEase (both from Cordis, Roden, Netherlands) vena cava filters in the prevention of pulmonary embolism (PE). Between May 2004 and December 2008, OptEase (permanent/retrievable; n = 228) or TrapEase (permanent; n = 30) vena cava filters were placed in 258 patients (160 female and 98 male; mean age 62 years [range 22 to 97]). Indications were as follows: prophylaxis for PE (n = 239), contraindication for anticoagulation in the presence of PE or DVT (n = 10), and development of PE or DVT despite anticoagulation (n = 9). Medical records were retrospectively reviewed for indications, clinical results, and procedure-related complications during placement and retrieval. Clinical PE did not develop in any of the patients. However, radiologic signs of segmental PE were seen in 6 of 66 patients with follow-up imaging data. Migration or fracture of the filter or cava perforation was not seen in any of the patients. Except for a single case of asymptomatic total cava thrombosis, no thrombotic occlusion was observed. One hundred forty-one patients were scheduled to undergo filter removal; however, 17 of them were not suitable for such based on venography evaluation. Removal was attempted in 124 patients and was successful in 115 of these (mean duration of retention 11 days [range 4 to 23]). Nine filters could not be removed. Permanent/retrievable vena cava filters are safe and effective devices for PE prophylaxis and for the management of venous thromboembolism by providing the option to be left in place.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

InGaSb Defect Filter Layer to Improve Performance of GaSb Solar Cells Grown on GaAs Substrates

The reduction of the threading dislocation density in metamorphic GaSb grown on GaAs substrates through the use of InGaSb defect filter layers has been investigated. More specifically, we study the effects of strain and thickness on the ability of a InGaSb defect filter layer to reduce threading dislocations in GaSb solar cells grown on GaAs substrates. The strain between the GaSb metamorphic layer on GaAs substrate (99.5% relaxed) and the InGaSb defect filter layer is varied by changing the indium composition in the InGaSb layer. Here, it is demonstrated that an InGaSb defect filter layer with 0.6% strain is more effective for blocking threading dislocations compared with higher-strain layers, resulting in improved short-circuit current (J sc ) and open-circuit voltage (V oc ) for the metamorphic GaSb solar cell. The optimization of the defect filter layer involves varying the thickness of the layer to achieve the lowest possible threading dislocation density. This also takes into account the critical thickness of the InGaSb layer on GaSb to avoid generation of threading dislocations from the InGaSb layer itself. It is shown that adding an In 0.11 Ga 0.89 Sb defect filter layer with thickness of 250 nm and 0.6% strain beneath a GaSb solar cell grown on a GaAs substrate improves V oc from 0.1 V to 0.16 V and J sc from 19.7 mA/cm 2 to 24.7 mA/cm 2 .

36 MATERIALS SCIENCE↗

Axial and transverse characterizations of ceramic candle filters

Ceramic candle filters are stiff composite tubes used in particle-removal during hot-gas filtration in coal energy generation. These filters are designed to withstand high temperature and pressure gradients. To determine the consistency in manufactured qualities of these filters, dynamic characterization method is recommended as a nondestructive evaluation technique. Six filters of the same manufactured batch were tested dynamically to establish the baseline properties of these filters. The test results are compared to theoretical values and are used to identify the variation in the manufactured products. This paper reports the frequencies in both transverse and axial directions indicating acceptable variations between all filters that are compatible to variations in measured physical parameters including density, stiffness and elastic modulus.

01 COAL, LIGNITE, AND PEAT↗

High-performance implementation of Chebyshev filter diagonalization for interior eigenvalue computations

We study Chebyshev filter diagonalization as a tool for the computation of many interior eigenvalues of very large sparse symmetric matrices. In this technique the subspace projection onto the target space of wanted eigenvectors is approximated with filter polynomials obtained from Chebyshev expansions of window functions. After the discussion of the conceptual foundations of Chebyshev filter diagonalization we analyze the impact of the choice of the damping kernel, search space size, and filter polynomial degree on the computational accuracy and effort, before we describe the necessary steps towards a parallel high-performance implementation. Because Chebyshev filter diagonalization avoids the need for matrix inversion it can deal with matrices and problem sizes that are presently not accessible with rational function methods based on direct or iterative linear solvers. To demonstrate the potential of Chebyshev filter diagonalization for large-scale problems of this kind we include as an example the computation of the 10{sup 2} innermost eigenpairs of a topological insulator matrix with dimension 10{sup 9} derived from quantum physics applications.

97 MATHEMATICS AND COMPUTING↗

Study of the filter method for neutron pulse-height distributions measured with organic scintillators

Identification of neutron sources is of interest in several fields, such as homeland security or basic nu-clear physics. Organic scintillators offer the possibility to unfold fast-neutron energy spectra. Since organic scintillators are sensitive to neutrons and gamma-rays, a method to discriminate these two types of particles is required. This paper is focused on investigation of the discrimination properties of the filter method by using a new procedure. We compare the results of an experimental filter method to a digital pulse-shape discrimination (PSD) method based on charge integration. In addition, these methods are compared to the simulation results obtained with the MCNPX-PoliMi code. The experimental and nu-merical investigations were performed with a 252Cf spontaneous-fission neutron source. The integration of the number of counts gave the relative differences between the experimental filter and digital PSD neutron pulse-height distributions (PHDs) and simulated PHDs less than approximately 5% in the range between 60 keVee and 1.715 MeVee of light output. Above 1.715 MeVee, the PSD method has advantages over the filter method, due to the filter method having significantly worse counting statistics. The results show that the filter method has potential for robust neutron measurements when the PSD method cannot be applied, such as for ‘old’ organic plastic scintillators without PSD capability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of high damage threshold laser-machined apodizers and gain filters for laser applications

We have developed high damage threshold filters to modify the spatial profile of a high energy laser beam. The filters are formed by laser ablation of a transmissive window. The ablation sites constitute scattering centers which can be filtered in a subsequent spatial filter. Finally, by creating the filters in dielectric materials, we see an increased laser-induced damage threshold from previous filters created using ‘metal on glass’ lithography.

47 OTHER INSTRUMENTATION↗

A Kalman filter for feedback control of rotating external kink instabilities in the presence of noise

The simulation and experimental optimization of a Kalman filter feedback control algorithm for n=1 tokamak external kink modes are reported. In order to achieve the highest plasma pressure limits in ITER, resistive wall mode stabilization is required [T. C. Hender et al., Nucl. Fusion 47, S128 (2007)] and feedback algorithms will need to distinguish the mode from noise due to other magnetohydrodynamic activity. The Kalman filter contains an internal model that captures the dynamics of a rotating, growing n=1 mode. This model is actively compared with real-time measurements to produce an optimal estimate for the mode's amplitude and phase. On the High Beta Tokamak-Extended Pulse experiment [T. H. Ivers et al., Phys. Plasmas 3, 1926 (1996)], the Kalman filter algorithm is implemented using a set of digital, field-programmable gate array controllers with 10 {mu}s latencies. Signals from an array of 20 poloidal sensor coils are used to measure the n=1 mode, and the feedback control is applied using 40 poloidally and toroidally localized control coils. The feedback system with the Kalman filter is able to suppress the external kink mode over a broad range of phase angles between the sensed mode and applied control field. Scans of filter parameters show good agreement between simulation and experiment, and feedback suppression and excitation of the kink mode are enhanced in experiments when a filter made using optimal parameters from the scans is used.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of active porous medium filters based on plasma textiles

Inexpensive, flexible, washable, and durable materials that serve as antimicrobial filters and self-decontaminating fabrics are needed to provide active protection to people in areas regularly exposed to various biohazards, such as hospitals and bio research labs working with pathogens. Airlines and cruise lines need such material to combat the spread of infections. In households these materials can be used in HVAC filters to fight indoor pollution, which is especially dangerous to people suffering from asthma. Efficient filtering materials are also required in areas contaminated by other types of hazardous dust particulates, such as nuclear dust. The primary idea that guided the undertaken study is that a microplasma-generating structure can be embedded in a textile fabric to generate a plasma sheath (''plasma shield'') that kills bacterial agents coming in contact with the fabric. The research resulted in the development of a plasma textile that can be used for producing new types of self-decontaminating garments, fabrics, and filter materials, capable of activating a plasma sheath that would filter, capture, and destroy any bacteriological agent deposited on its surface. This new material relies on the unique antimicrobial and catalytic properties of cold (room temperature) plasma that is benign to people and does not cause thermal damage to many polymer textiles, such as Nomex and polypropylene. The uniqueness of cold plasma as a disinfecting agent lies in the inability of bacteria to develop resistance to plasma exposure, as they can for antibiotics. Plasma textiles could thus be utilized for microbial destruction in active antimicrobial filters (for continuous decontamination and disinfection of large amounts of air) as well as in self-decontaminating surfaces and antibacterial barriers (for example, for creating local antiseptic or sterile environments around wounds and burns).

36 MATERIALS SCIENCE↗

Model of the boundary layer of a vacuum-arc magnetic filter

A model is developed to describe the electrostatic boundary layer in a positively biased magnetic filter in filtered arcs with low collisionality. The set of equations used includes the electron momentum equation, with an anomalous collision term due to micro-instabilities leading to Bohm diffusion, electron mass conservation, and Poisson equation. Analytical solutions are obtained, valid for the regimes of interest, leading to an explicit expression to determine the electron density current to the filter wall as a function of the potential of the filter and the ratio of electron density at the plasma to that at the filter wall. Using a set of planar and cylindrical probes it is verified experimentally that the mentioned ratio of electron densities remains reasonably constant for different magnetic field values and probe bias, which allows to obtain a closed expression for the current. Comparisons are made with the experimentally determined current collected at different sections of a positively biased straight filter.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photonic crystal ring resonator based optical filters for photonic integrated circuits

In this paper, a two Dimensional (2D) Photonic Crystal Ring Resonator (PCRR) based optical Filters namely Add Drop Filter, Bandpass Filter, and Bandstop Filter are designed for Photonic Integrated Circuits (PICs). The normalized output response of the filters is obtained using 2D Finite Difference Time Domain (FDTD) method and the band diagram of periodic and non-periodic structure is attained by Plane Wave Expansion (PWE) method. The size of the device is minimized from a scale of few tens of millimeters to the order of micrometers. The overall size of the filters is around 11.4 μm × 11.4 μm which is highly suitable of photonic integrated circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiple attenuation to reflection seismic data using Radon filter and Wave Equation Multiple Rejection (WEMR) method

Separation between signal and noise, incoherent or coherent, is important in seismic data processing. Although we have processed the seismic data, the coherent noise is still mixing with the primary signal. Multiple reflections are a kind of coherent noise. In this research, we processed seismic data to attenuate multiple reflections in the both synthetic and real seismic data of Mentawai. There are several methods to attenuate multiple reflection, one of them is Radon filter method that discriminates between primary reflection and multiple reflection in the τ-p domain based on move out difference between primary reflection and multiple reflection. However, in case where the move out difference is too small, the Radon filter method is not enough to attenuate the multiple reflections. The Radon filter also produces the artifacts on the gathers data. Except the Radon filter method, we also use the Wave Equation Multiple Elimination (WEMR) method to attenuate the long period multiple reflection. The WEMR method can attenuate the long period multiple reflection based on wave equation inversion. Refer to the inversion of wave equation and the magnitude of the seismic wave amplitude that observed on the free surface, we get the water bottom reflectivity which is used to eliminate the multiple reflections. The WEMR method does not depend on the move out difference to attenuate the long period multiple reflection. Therefore, the WEMR method can be applied to the seismic data which has small move out difference as the Mentawai seismic data. The small move out difference on the Mentawai seismic data is caused by the restrictiveness of far offset, which is only 705 meter. We compared the real free multiple stacking data after processing with Radon filter and WEMR process. The conclusion is the WEMR method can more attenuate the long period multiple reflection than the Radon filter method on the real (Mentawai) seismic data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and evaluation of a HDR skin applicator with flattening filter

The purposes of this study are: (i) to design field flattening filters for the Leipzig applicators of 2 and 3 cm of inner diameter with the source traveling parallel to the applicator contact surface, which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands). These filters, made of tungsten, aim to flatten the heterogeneous dose distribution obtained with the Leipzig applicators. (ii) To estimate the dose rate distributions for these Leipzig+filter applicators by means of the Monte Carlo (MC) method. (iii) To experimentally verify these distributions for prototypes of these new applicators, and (iv) to obtain the correspondence factors to measure the output of the applicators by the user using an insert into a well chamber. The MC GEANT4 code has been used to design the filters and to obtain the dose rate distributions in liquid water for the two Leipzig+filter applicators. In order to validate this specific application and to guarantee that realistic source-applicator geometry has been considered, an experimental verification procedure was implemented in this study, in accordance with the updated recommendations of the American Association of Physicists in Medicine Task Group No. 43 U1 Report. Thermoluminescent dosimeters, radiochromic film, and a pin-point ionization chamber in a plastic [polymethylmethacrylate (PMMA)] phantom were used to verify the MC results for the two applicators of a microSelectron-HDR afterloader with the mHDR-v2 source. To verify the output of the Leipzig+filter applicators, correspondence factors were deduced for the well chambers HDR100-plus (Standard Imaging, Inc., Middleton, WI) and TM33004 (PTW, Freiburg, Germany) using a specific insert for both applicators. The doses measured in the PMMA phantom agree within experimental uncertainties with the dose obtained by the MC calculations. Percentage depth dose and off-axis profiles were obtained normalized at a depth of 3 mm along the central applicator axis in a cylindrical 20x20 cm water phantom. A table of output factors, normalized to 1 U of source air kerma strength at this depth, is presented. Correspondence factors were obtained for the two well chambers considered. The matrix data obtained in the MC simulation with a grid separation of 0.5 mm has been used to build a data set in a convenient format to model these distributions for routine use with a brachytherapy treatment planning system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗