Deciphering volume changes in Li-S solid-state battery components during cycling: Implication for advanced battery design

Here, in this work, we developed custom fixtures to investigate the mechanical and electrochemical behavior of all-solid-state lithium batteries during cycling under constant pressure and constant volume conditions. We successfully monitored vertical displacements during constant pressure cycling and pressure variations during constant volume cycling, allowing us decouple volume changes in the sulfur, Li 2 S cathodes, LixIn anode, and solid-state electrolyte. Scanning electron microscopy and electrochemical impedance spectroscopy confirmed that two structural changes occur during ASSLB cycling: (1) irreversible fractures in the active material particles, and (2) void formation within the electrode matrix. While the fractures in primary particles are permanent, void formation can be mitigated through stack pressure, which promotes particle rearrangement in the electrode matrix. Our findings emphasize the importance of stack pressure in maintaining the microscale integrity of all-solid-state lithium batteries, preventing void formation and enhance battery performance and durability.

Cell Design↗

Stabilizing a strongly nonlinear structure through shaker dynamics in fixed frequency voltage control tests

Bifurcations are commonly encountered during force controlled swept and stepped sine testing of nonlinear structures, which generally leads to the so-called jump-down or jump-up phenomena between stable solutions. There are various experimental closed-loop control algorithms, such as control-based continuation and phase-locked loop, to stabilize dynamical systems through these bifurcations, but they generally rely on specialized control algorithms that are not readily available with many commercial data acquisition software packages. A recent method was developed to experimentally apply sequential continuation using the shaker voltage that can be readily deployed using commercially available software. By utilizing the stabilizing effects of electrodynamic shakers and the force dropout phenomena in fixed frequency voltage control sine tests, this approach has been demonstrated to stabilize the unstable branch of a nonlinear system with three branches, allowing for three multivalued solutions to be identified within a specific frequency bandwidth near resonance. Recent testing on a strongly nonlinear system with vibro-impact nonlinearity has revealed jumping behavior when performing sequential continuation along the voltage parameter, like the jump phenomena seen during more traditional force controlled swept and stepped sine testing. Here, this paper investigates the stabilizing effects of an electrodynamic shaker on strongly nonlinear structures in fixed frequency voltage control tests using both numerical and experimental methods. The harmonic balance method is applied to the coupled shaker-structure system with an electromechanical model to simulate the fixed voltage control tests and predict the stabilization for different parameters of the model. The simulated results are leveraged to inform the design of a set of experiments to demonstrate the stabilization characteristics on a fixture-pylon assembly with a vibro-impact nonlinearity. Through numerical simulation and experimental testing on two different strongly nonlinear systems, the various parameters that influence the stability of the coupled shaker-structure are revealed to better understand the performance of fixed frequency voltage control tests.

42 ENGINEERING↗

Prediction of dynamic behavior of a system undergoing an exchange of components using a transmission simulator method

In systems with modular design, it is of interest to perform component exchanges to upgrade components and explore new system configurations. If the dynamics of the components are known, then dynamic substructuring can be used to obtain a prediction of system performance for the new configuration. The transmission simulator method is a substructuring technique that utilizes an additional fixture to apply an elastic boundary condition to a test article such that an appropriate dynamic response can be obtained for a given substructuring application, and the technique has been used widely for performing coupling and decoupling operations. Here, in this work, a modified transmission simulator method is proposed that allows a direct exchange of components to be performed. In a numerical demonstration, the proposed method is shown to accurately predict the dynamics of an assembly that has undergone a component exchange in which the exchanged components have different material properties and different geometric properties. This approach can be applied to dynamic qualification frameworks in which structures undergo modifications or upgrades rather than complete redesigns.

Component exchange↗

Cost Estimates of Roll-to-Roll Production of Organic Light Emitting Devices for Lighting

White organic light emitting devices (WOLEDs) offerdistinct advantages as solid state lighting sources, including high energy efficiency, superior color quality,and a flexible, thin profile that can accommodate a vast array of possible fixture designs. Recent advances in device lifetime and high speed deposition suggest that mass production of WOLED panels is approaching an inflection point. To understand the tradeoffs in the volume manufacturing of WOLED lighting panels, in this work, we estimate the cost of white WOLED panel production based on vacuum and vapor phase deposition in a roll-to-roll production line envisioned to yield an annual capacity of at least 6 × 10 6 m 2 . Assuming a WOLED operating luminance at 10 klm/m 2 , we anticipate a $\$12.5$ /klm cost of a WOLED light engine that includes the cost of the current driverand packaging. With incremental reduction in material and driver costs and improved luminance, the costof WOLED lighting can be reduced to $\$6.3$ /klm in thenear term, potentially positioning WOLEDs for use innumerous premium lighting applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Linking in silico MS/MS spectra with chemistry data to improve identification of unknowns

Confident identification of unknown chemicals in high resolution mass spectrometry (HRMS) screening studies requires cohesive workflows and complementary data, tools, and software. Chemistry databases, screening libraries, and chemical metadata have become fixtures in identification workflows. To increase confidence in compound identifications, the use of structural fragmentation data collected via tandem mass spectrometry (MS/MS or MS2) is vital. However, the availability of empirically collected MS/MS data for identification of unknowns is limited. Researchers have therefore turned to in silico generation of MS/MS data for use in HRMS-based screening studies. This paper describes the generation en masse of predicted MS/MS spectra for the entirety of the US EPA’s DSSTox database using competitive fragmentation modelling and a freely available open source tool, CFM-ID. The generated dataset comprises predicted MS/MS spectra for ~700,000 structures, and mappings between predicted spectra, structures, associated substances, and chemical metadata. Together, these resources facilitate improved compound identifications in HRMS screening studies. These data are accessible via an SQL database, a comma-separated export file (.csv), and EPA’s CompTox Chemicals Dashboard.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flexible germanium nanomembrane metal-semiconductor-metal photodiodes

We demonstrate flexible Ge nanomembrane (Ge NM) based metal-semiconductor-metal photodiodes. The effect of uniaxial tensile strain on Ge NM based photodiodes was investigated using bending fixtures. Dark current density is decreased from 21.5 to 4.8 mA/cm{sup 2} at 3 V by a tensile strain of 0.42% while photon responsivity is increased from 0.2 to 0.45 A/W at the wavelength of 1.5 μm. Enhanced responsivity is also observed at longer wavelengths up to 1.64 μm. The uniaxial tensile strain effectively reduces the direct bandgap energy of the Ge NM, leading to a shift of the absorption edge toward a longer wavelength.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of the dynamic densification behavior of cerium dioxide powders as a function of green density

The uniaxial strain dynamic densification behavior of cerium dioxide powders as a function of powder compact green density is investigated in this work. Cerium dioxide powders of two particle morphologies (rod-like and equiaxed) and two green densities (55% and 62.5% TMD) are shock compressed using the gas gun with specifically designed fixtures and their particle and shock wave velocities are measured using VISAR and multiple PDV probes. The obtained data describe the Hugoniot of the shocked cerium dioxide powders. Finally, the method used to produce this high fidelity Hugoniot data for cerium dioxide powders is discussed and preliminary data are shown.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Inter-digital capacitive sensor for evaluating cable jacket and insulation aging

An inter-digital capacitive (TDC) sensor has previously been used to measure dielectric properties of cable insulation polymer material when placed in direct contact with the insulation. Often cable insulation is covered by a polymer jacket. The dielectric properties of many cable jacket and insulation polymers are known to change due to thermal and radiation exposure-related damage. These dielectric properties frequently track with other measures of cable aging, such as tensile elongation-at-break and indenter modulus that have been broadly established as cable insulation polymer assessment methods. The external jacket of a cable is likely to have a different permittivity from the underlying insulation, and frequently the jacket material exhibits more severe damage than the insulation material due to environmental exposure. Because the jacket serves primarily to guard the cable during installation, as long as the underlying insulation condition is acceptable, the jacket condition is relatively unimportant in service. As part of a continuing program to develop and evaluate nondestructive examination methods that may be applied to cable condition assessment, a set of tools has been developed including (1) a parallel-plate sensor to directly measure the permittivity spectrum of flat sheet material and (2) an TDC and fixture to measure the effect of cable polymer dielectric property change on the sensor response. The TDC consists of two fork-like electrodes facing each other with the fork tines interspersed and separated by a small gap. The electrodes are printed on one side of a flexible substrate that can be conformed to the surface of a cylindrical cable, with tines parallel to the cable axis. The electrodes are connected to a broad-frequency-spectral impedance meter that senses the capacitance between the narrowly gapped electrode tines. This capacitance is known to vary as a function of the permittivity of any material in close proximity to the electrodes. By finite element modeling (FEM) and experimentation, this study investigates the effect of tine spacing and other design parameters associated with the TDC on the voltage (potential) distribution and electric field depth of penetration. The TDC measurement of an unshielded ethylene-propylene rubber (EPR)-insulated cable is shown to track with the degree of aging and quantities obtained by established methods. For jacketed cable systems, the TDC response is dominated by the jacket but, by analyzing measurements from TDC sensors with different depths-of-field penetration into the cable under test, the influence of the chlorinated polyethylene (CPE) cable jacket material degradation can be separated from an assessment of the cable insulation thereby enabling assessment of the insulation beneath/through the jacket.

Cable NDE, Interdigital Capacitance, Cable test↗

Intrinsic quality factor extraction of multi-port cavity with arbitrary coupling

In this work, we derived S-parameter based expressions for the intrinsic quality factor of an arbitrary coupled multiport microwave cavity and a non-ideal test fixture. Practical accuracy limitations of the obtained expressions specifically for superconducting accelerator cavities were evaluated both analytically and with the simulation software. The resulting formulas can be used to extract the intrinsic quality factor of normal-conducting and superconducting cavities directly from the calibrated S-parameter measurements.

43 PARTICLE ACCELERATORS↗

Simultaneous determination of electrical conductivity and thickness of nonmagnetic metallic foils using two-sided multifrequency eddy current techniques

Here, in this paper, we describe a simple method for performing multifrequency eddy current characterization of free-standing uniform-thickness metallic foils using a forked inductive coil arrangement. The method involves measuring the mutual inductance between two coils when a foil is present between the coils, and when it is not present; the ratio of these mutual inductances is compared with an analytical solution, and foil conductivity, thickness, and sheet resistance are simultaneously estimated using numerical inversion and least-squares fitting. This method was used to characterize 34 non-ferrous metallic samples with thicknesses between 50 and 640 μm and with conductivities between 0.8 × 10 7 and 5.8 × 10 7 S/m. The estimated thicknesses from eddy current characterization agreed well with those measured using confocal optical techniques; the two approaches agreed to within 1 μm for samples that were thinner than 200 μm, and to within 0.5% for samples that had a thickness of 200 μm or greater. The estimated conductivities from eddy current characterization were in close agreement with expected values, given knowledge of the materials used. A particular strength of this approach is that the instrumentation needed is broadly available in research and development laboratories and the associated fixturing is easy to manufacture and assemble. A calibration procedure is described that can be used to reduce errors from geometric uncertainties. This calibration requires a sample that has only a known conductivity or thickness; both do not need to be known. The method described herein is likely extensible to conductivities and thickness well outside the ranges measured as part of this work.

47 OTHER INSTRUMENTATION↗

In-Canal Assay of High Specific Activity 60 Co at the Advanced Test Reactor

Production of high specific activity (HSA) 60 Co has recently resumed at the Advanced Test Reactor (ATR) at the Idaho National Laboratory. The technical steps of performing in-canal assay of HSA 60 Co targets at the ATR are described herein. The HSA targets are assayed on a regular basis, between cycles at the ATR, in order to assess the progress of activation. The targets are also assayed at the conclusion of the irradiation in order to provide activity estimates for the distributor and to be used for safety and shipping evaluations. These target assay activities must take place in the ATR canal to provide sufficient radiological shielding. Furthermore, a specialized assay fixture is used in conjunction with custom 60 Co radiation standards to assess the irradiated target. The specific activity of each irradiated target was determined by first measuring the 60 Co standards to determine a sensitivity factor. Then, each irradiated target was measured, and the integrated measurement was multiplied by the sensitivity factor to determine the total activity of the irradiated target. Finally, a correction factor was determined to adjust the reported activity, accounting for differences in the physical geometries of the standards and targets. These methods were used to accurately assay the gross activity of nine irradiated 60 Co targets, two of which were delivered to the distributor where confirmatory hot-cell assays were performed verifying the accuracy of the in-canal assay method.

07 ISOTOPE AND RADIATION SOURCES↗

High-precision vapor pressure measurement apparatus with facile and inexpensive construction

This study describes an apparatus for high-precision variable temperature measurement of liquid vapor pressure. The apparatus can be used to measure the vapor pressure using only 0.5 ml of the liquid sample. To evaluate the accuracy of the device measurement, water and 2-propanol are utilized as standard liquids, and their vapor pressure is measured with a maximum uncertainty of ~1%. This apparatus can be replicated using inexpensive and commonly used laboratory fittings and fixtures, making it an indispensable tool for synthetic chemists and chemical engineers involved in the iterative synthesis of compounds, targeting different vapor–liquid equilibrium regimes.

Engineering↗

Shielded magnetic small-angle neutron scattering for characterization of radioactive samples

The development of a Pb-shielded fixture for the execution of a small-angle neutron scattering (SANS)-based workflow for interrogation of highly irradiated nuclear materials has been explored. The Pb shielding was specially designed to reduce the detected radioactivity from the specimen during SANS experiments, and the overall configuration is termed shielded magnetic SANS (SM-SANS). Two FeCrAl-based alloys, C35M and 125YF, were examined with the SM-SANS technique using a free-form size distribution locally monodisperse model in both the as-received and irradiated states. Quantitative values derived from the free-form size distribution were compared with atom probe tomography experiments. Microstructural and compositional parameters determined using the two characterization techniques were complements of each other. The results demonstrate that the SM-SANS technique is an effective means of characterizing nanoscale clustering in irradiated material systems and provides new avenues for investigating radioactive material microstructures.

FeCrAl↗

PLC-based Impedance Measurement and Current Injection Response Analysis

Studying and mitigating the vulnerabilities of Programmable Logic Controllers (PLCs) to electromagnetic pulse is important for the reliability of the power system. In this paper, an effective impedance measurement scheme is proposed to estimate the susceptibility of PLCs to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulse Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of PLC.

Qiu, Wei↗

Voltage and Current Response Characteristics of PMU Device by PCI Simulation

Phasor Measurement Units (PMUs) are critical for the Wide Area Measurement System (WAMS), especially for real-time grid monitoring, disturbance location, and situation awareness. Once they are damaged, the stable operation of power system will be affected directly and greatly. As new electronic devices in power system, their immunity to electromagnetic pulse (EMP) events needs to be studied. In this paper, an effective impedance measurement scheme is proposed for port impedance measurement of PMU. A non-uniform transmission line model is established to eliminate the impact of fixture in the de-embedding process. Then circuit of pulse current generator is established to generate damping sinusoid and double exponential wave applied to the port. Finally, by using measured impedance as load of the generator, the voltage and current responses of different ports are calculated in the pulsed current injection (PCI) simulation. Results shows the characteristics of port impedance, voltage and current waveforms. The relation between port impedance and the waveforms is discussed.

Zhang, Liang↗

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

Phasor Measurement Units (PMUs) are critical for the Wide Area Measurement System (WAMS), especially for real-time grid monitoring, disturbance location, and situation awareness. Once they are damaged, the stable operation of the power system will be affected directly and greatly. Therefore, it is urgent and necessary to study their immunity to electromagnetic pulse (EMP) events. In this paper, an effective impedance measurement scheme is proposed for port impedance measurement of PMU. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then circuit of pulsed current generator is established to generate damping sinusoid and double exponential wave applied to the port. Finally, by using measured impedance as a load of the generator, the voltage and current responses of different ports are calculated in the pulsed current injection (PCI) testing simulation. Results show that common-mode impedance is large and differential mode impedance is small. The critical condition will appear in the common mode for voltage and differential mode for current.

Zhang, Liang↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 degrees C from ~40 degrees C) and a different failure mode were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy).

balance of systems↗

Mechanical Utility Structure for Testing High Field Superconducting Dipole Magnets

The U.S. Magnet Development Program (MDP) collaboration is designing a utility mechanical structure for testing various high-field superconducting dipole coils. The design uses a shell-based structure concept, which allows applying preload in two steps: During a room temperature assembly and during a cool down to a cryogenic temperature. The structure is designed to accommodate various coil designs - including Nb 3 Sn Cosine Theta (CT) and Canted CT magnets as well as hybrid magnets with high temperature superconductor cables. Superconducting coils, enclosed by bolted pads to form an octagonal coil pack, will be inserted into a reusable yoke-shell subassembly and precisely preloaded during the assembly using a bladder-and-key technology. Due to a differential thermal contraction between an external aluminum shell and the magnet core, the coil preload increases during the cool down up to level required for 17-T excitation. Such a reusable structure will serve as a testing fixture supporting goals of the MDP program, decreasing cost and simplifying coil performance testing at different preload levels. We present a finite-element analysis of the structure preloading various coil designs and examine the predicted coil stress at each step of the magnet assembly and excitation.

43 PARTICLE ACCELERATORS↗