Test report for 8-inch Check Valve Mission Valve and Pump Company part number 15 CPF-311 NASA drawing number 75M17763 HCV-9
Functional and environment testing of 8-inch valve used in vaporizer units and umbilical tower hydrogen vent
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Functional and environment testing of 8-inch valve used in vaporizer units and umbilical tower hydrogen vent
The purpose of the project was to evaluate DuAlumin-3D, an ORNL designed Al alloy, for additive manufacturing of high-performance automotive components. The project consisted of additively manufacturing a cylindrical block of representative material which was then heat treated before machining into test coupons. Testing included tensile tests as a function of temperature, high-cycle fatigue testing as a function of temperature, density and elastic modulus measurements, and thermophysical property measurements. Fractography was also performed on failed high-cycle fatigue specimens. The results were compared against benchmark AM Al alloys and current high-performance conventionally manufactured alloys. Overall, the DuAlumin-3D material outperformed the incumbent materials in mechanical properties, especially at elevated temperatures, while maintaining broadly similar thermophysical properties. The results of this study support further maturation of the material for additive manufacturing of high-performance automotive components.
A vibration-based testing methodology has been developed that will assess fatigue behavior of the metallic material of construction for the Advanced Stirling Convertor displacer (planar) spring component. To minimize the testing duration, the test setup is designed for base-excitation of a multiplespecimen arrangement, driven in a high-frequency resonant mode; this allows completion of fatigue testing in an accelerated period. A high performance electro-dynamic exciter (shaker) is used to generate harmonic oscillation of cantilever beam specimens, which are clasped on the shaker armature with specially-designed clamp fixtures. The shaker operates in closed-loop control with dynamic specimen response feedback provided by a scanning laser vibrometer. A test coordinator function synchronizes the shaker controller and the laser vibrometer to complete the closed-loop scheme. The test coordinator also monitors structural health of the test specimens throughout the test period, recognizing any change in specimen dynamic behavior. As this may be due to fatigue crack initiation, the test coordinator terminates test progression and then acquires test data in an orderly manner. Design of the specimen and fixture geometry was completed by finite element analysis such that peak stress does not occur at the clamping fixture attachment points. Experimental stress evaluation was conducted to verify the specimen stress predictions. A successful application of the experimental methodology was demonstrated by validation tests with carbon steel specimens subjected to fully-reversed bending stress; high-cycle fatigue failures were induced in such specimens using higher-than-prototypical stresses
Fitting a space suit to a person could be considered an art form. Establishing a repeatable fitcheck process to accommodate the full anthropometric range of test subjects for a single suit design is a critical process to be able to prove suit functionality. Suited test subjects can have different preferences on how they fit inside a suit, and different suited test environments can lead to differences in certain suit sizing accommodations. Throughout this paper, the process of achieving an acceptable suit fit for test subjects will be discussed, along with sizing considerations for changes in suit design and test environments. Lessons learned from the Exploration Extravehicular Mobility Unit (xEMU) will be used to describe specific examples, along with key takeaways from additional NASA prototype mobility space suits. The suit fitcheck process starts with utilizing the anthropometric measurements of a test subject to evaluate their relation to the dimensions of space suit hardware in creating a predicted suit sizing configuration. From here, subjective comments and test team observations drive iterations to the suit sizing configuration to culminate in an acceptable suit fit for performance of further test evaluations. Understanding the relation of subjective comments to their impact on altering suit sizing is critical in establishing an acceptable suit fit.
Fitting a space suit to a person could be considered an art form. Establishing a repeatable fitcheck process to accommodate the full anthropometric range of test subjects for a single suit design is a critical process to be able to prove suit functionality. Suited test subjects can have different preferences on how they fit inside a suit, and different suited test environments can lead to differences in certain suit sizing accommodations. Throughout this paper, the process of achieving an acceptable suit fit for test subjects will be discussed, along with sizing considerations for changes in suit design and test environments. Lessons learned from the Exploration Extravehicular Mobility Unit (xEMU) will be used to describe specific examples, along with key takeaways from additional NASA prototype mobility space suits. The suit fitcheck process starts with utilizing the anthropometric measurements of a test subject to evaluate their relation to the dimensions of space suit hardware in creating a predicted suit sizing configuration. From here, subjective comments and test team observations drive iterations to the suit sizing configuration to culminate in an acceptable suit fit for performance of further test evaluations. Understanding the relation of subjective comments to their impact on altering suit sizing is critical in establishing an acceptable suit fit.
An advanced state-of-the-art steam turbine-generator developed to serve as the power conversion subsystem for the Department of Energy's Sandia National Laboratories' Solar Total-Energy Project (STEP) is described. The turbine-generator, which is designed to provide 400-kW of net electrical power, represents the largest turbine-generator built specifically for commercial solar-powered cogeneration. The controls for the turbine-generator incorporate a multiple, partial-arc entry to provide efficient off-design performance, as well as an extraction control scheme to permit extraction flow regulation while maintaining 110-spsig pressure. Normal turbine operation is achieved while synchronized to a local utility and in a stand-alone mode. In both cases, the turbine-generator features automatic load control as well as remote start-up and shutdown capability. Tests totaling 200 hours were conducted to confirm the integrity of the turbine's mechanical structure and control function. Performance tests resulted in a measured inlet throttle flow of 8,450 pounds per hour, which was near design conditions.
Material and performance tests of water boiler and water sublimator heat sink modules
Stress relaxation cracking (SRC) is considered one of the major failure mechanisms for 347H stainless steel welds at elevated service temperatures or during post weld heat treatment (PWHT), especially within the heat-affected zone (HAZ). This work focuses on the characterization of SRC susceptibility within 347H physically simulated arc welded HAZ at elevated temperatures. A four-step SRC thermomechanical test in combination with finite element modeling (FEM) of the welding and testing processes is developed to establish a susceptibility map for HAZ. The test first runs a thermal cycle with three different peak temperatures (1335, 1275, and 1150 °C) to duplicate representative HAZ subzone microstructures, followed by time-to-failure examination under a variety of pre-stress (260–600 MPa) and pre-strain conditions (0.03–0.19) as a function of reheat temperatures between 750 and 1050 °C. With the aid of FEM, SRC susceptibility maps are generated to identify the threshold stress, plastic strain, and creep strain as a function of test temperature. It was found out that HAZ subzone with a lower peak temperature (1150 °C) appears to be slightly less susceptible to SRC than the other two subzones that experienced higher peak temperatures. Generally, time-to-fracture reduces with increasing initially applied stress and strain for all test temperatures. The pre-stress thresholds decrease from about 500 to 330 MPa as the testing temperature increases from 800 to 1050 °C, while the corresponding initial plastic strain thresholds reduces from 0.15 to 0.06. The SRC susceptibility was also evaluated through the Larson–Miller Parameter (LMP) analysis as a function of plastic strain, initial stress and starting stress upon reaching the testing temperature, respectively. The 1050 °C test with a high pre-applied strain (0.1) exhibits an extremely short time to failure (t = 3 s) that lies outside the general trend in LMP analysis. Additionally, it was identified that a plastic strain above 0.07 is identified to significantly reduce the bulk creep strain tolerance to fracture and therefore increases SRC susceptibility. Hardness measurement and fractography analysis indicated that the strain aging of niobium carbonitrides and other potential phases in conjunction with intergranular precipitates contributes to an increase in microhardness and increased intergranular cracking susceptibility.
A full-scale helicopter with four different blade-tip geometries was tested in the 40- by 80-foot wind tunnel at Ames Research Center. Performance, loads, and noise were measured. The four tip shapes tested were rectangular, tapered, swept, and swept-tapered. Noise measurements from that test are presented in the form of tables and plots. The noise data include measurements of the sound pressure level in dB, dBA, and tone-corrected PNdB, for all of the conditions tested. Detailed measurements, 1/3-octave spectra and time-histories for some selected data are included as well as plots of dBA as function of test condition. Some performance measurements are given to aid interpretation of the noise data.
A full scale helicopter with four different blade tip geometries is tested in a 40- by 80-foot wind tunnel. Performance, loads, and noise are measured. The four tip shapes tested were rectangular, tapered, swept, and swept/tapered. The noise data include measurements of the sound pressure levels in decibels dB, decibels adjusted dBA, and tone-corrected PNdB, for all of the conditions tested. Also included are the detailed measurements, 1/3 octave spectra and time histories for some selected data, and plots of dBA as function of test condition. Some performance measurements are included to aid interpretation of the noise data.
A potentially important source of structure-borne interior noise transmission in advanced turboprop aircraft is the impingement of the propeller wake/vortex on downstream aerodynamic surfaces. It can only be safely assumed that this potential source of interior noise may well hold up achievable interior noise levels unless noise control measures are conscientiously incorporated into the aircraft design. Through the use of a laboratory based test apparatus, techniques were developed to estimate the level of in-flight structure-borne noise transmission from combined frequency response function ground testing and in-flight structural response measurements. All phases of the test procedure were simulated in the laboratory and the expected level of accuracy of the procedure is addressed.
A potentially important source of structure-borne interior noise transmission in advanced turboprop aircraft is the impingement of the propeller wake/vortex on downstream aerodynamic surfaces. It can be safely assumed that this potential source of interior noise may well adversely affect achievable interior noise levels unless noise control measures are conscientiously incorporated into the aircraft design. Through the use of a laboratory-based test apparatus, techniques were developed to estimate the level of in-flight structure-borne noise transmission from combined frequency response function ground testing and in-flight structural response measurements. All phases of the procedure were simulated in the laboratory and the expected level of accuracy of the procedure is addressed.
Gear contact surface wear is one of the important failure modes for gear systems. Dedicated experiments are required to enable precise evaluations of gear wear for a particular application. The application of interest for this study required evaluation of wear of gears lubricated with a grade 2 perfluorinated polyether grease and having a dithering (rotation reversal) motion. Experiments were conducted using spur gears made from AISI 9310 steel. Wear was measured using a profilometer at test intervals encompassing 10,000 to 80,000 cycles of dithering motion. The test load level was 1.1 GPa maximum Hertz contact stress at the pitch-line. The trend of total wear as a function of test cycles was linear, and the wear depth rate was approximately 1.2 nm maximum wear depth per gear dithering cycle. The observed wear rate was about 600 times greater than the wear rate for the same gears operated at high speed and lubricated with oil.
NASA Ames Research Center and the George Washington University are developing an electric propulsion subsystem that will be integrated into the PhoneSat bus. Experimental tests have shown a reliable performance by firing three different thrusters at various frequencies in vacuum conditions. The interface consists of a microcontroller that sends a trigger pulse to the Pulsed Plasma Unit that is responsible for the thruster operation. A Smartphone is utilized as the main user interface for the selection of commands that control the entire system. The propellant, which is the cathode itself, is a solid cylinder made of Titanium. This simplicity in the design avoids miniaturization and manufacturing problems. The characteristics of this thruster allow an array of μCATs to perform attitude control and orbital correction maneuvers that will open the door for the implementation of an extensive collection of new mission concepts and space applications for CubeSats. NASA Ames is currently working on the integration of the system to fit the thrusters and the PPU inside a 1.5U CubeSat together with the PhoneSat bus. This satellite is intended to be deployed from the ISS in 2015 and test the functionality of the thrusters by spinning the satellite around its long axis and measure the rotational speed with the phone gyros. This test flight will raise the TRL of the propulsion system from 5 to 7 and will be a first test for further CubeSats with propulsion systems, a key subsystem for long duration or interplanetary small satellite missions.
Over the past year, two Rogue GPS prototype receivers have been assembled and successfully subjected to a variety of laboratory and field tests. A functional description is presented of signal processing in the Rogue receiver, tracing the signal from RF input to the output values of group delay, phase, and data bits. The receiver can track up to eight satellites, without time multiplexing among satellites or channels, simultaneously measuring both group delay and phase for each of three channels (L1-C/A, L1-P, L2-P). The Rogue signal processing described requires generation of the code for all three channels. Receiver functional design, which emphasized accuracy, reliability, flexibility, and dynamic capability, is summarized. A detailed functional description of signal processing is presented, including C/A-channel and P-channel processing, carrier-aided averaging of group delays, checks for cycle slips, acquistion, and distinctive features.
Spacecraft thermal control is accomplished for many components through use of multilayer insulation systems, electrical heaters, and radiator systems. The heaters are commanded to maintain component temperatures within design specifications. The programmable heater control circuit (PHCC) was designed to obtain an effective and efficient means of spacecraft thermal control. The hybrid circuit provides use of control instrumentation as temperature data, available to the spacecraft central data system, reprogramming capability of the local microprocessor during the spacecraft's mission, and the elimination of significant spacecraft wiring. The hybrid integrated circuit has a temperature sensing and conditioning circuit, a microprocessor, and a heater power and control circuit. The device is miniature and housed in a volume which allows physical integration with the component to be controlled. Applications might include alternate battery-powered logic-circuit configurations. A prototype unit with appropriate physical and functional interfaces was procured for testing. The physical functionality and the feasibility of fabrication of the hybrid integrated circuit were successfully verified. The remaining work to develop a flight-qualified device includes fabrication and testing of a Mil-certified part. An option for completing the PHCC flight qualification testing is to enter into a joint venture with industry.
Introduction: When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed spacecraft meet planetary protection requirements—and to protect our science from human contamination—we'll need to assess and verify whether micro-organisms may be leaking/venting from our spacesuits. This requires collecting samples under Extravehicular Activity (EVA) conditions. Detailed, systematic research on forward contamination from robotic spacecraft has been steadily progressing since the Viking missions, but systematic studies of contamination from space suits has not been conducted in many years. The modern EMU (Extravehicular Mobility Unit) suit used by NASA is designed to leak at rates as high as 100 cc/min. Before humans land on Mars there is a critical need to understand the types and quantities of microbes that could be introduced via space suits. The Human Forward Contamination Assessment team at NASA’s Johnson Space Center (JSC) has developed a prototype EVA swab tool [1,2,3,4] designed for use in space to sample cleaned and uncleaned space suits to determine the present day microbial load and eventually the rate of leakage. The ability to assess microbial leakage early in advanced space suit and life support system design cycles will help avoid costly hardware redesign later. Test Objectives: The primary objective of EMU testing was to characterize the type of micro-organisms typically found on or near selected suit pressure joints under suit differential pressure conditions. Most human-borne microbes can fit through a 0.5 to 1.0 µm gap. Knowing which joints are more likely to leak will inform hardware design decisions. Knowing which types of micro-organisms may leak from EVA suits provides a basis for subsequent studies to characterize the viability of those organisms under destination conditions, as well as how far they might spread through natural or human-influenced processes. That data, in turn, will inform exploration mission operations and hardware design. The secondary objective of testing was to evaluate the interface between a fully suited test subject and the EVA swab tool at vacuum. Bulky EVA suits can restrict movement and limit visibility through the helmet visor. Fully suited testing is important for identifying tool design issues prior to flight. At exploration destinations, such as Mars, suited crew may be required to periodically sample their suits as part of an environmental monitoring protocol. Suit Microbial Sampling Results: This report details results of microbial swabs collected from current flight suit configurations worn by crew members assigned to upcoming ISS expedition missions as well as swabs collected from prototype suits intended for use on the Orion spacecraft. These tests were intended to characterize the types of contaminants found on flight suits under current, typical handling conditions. No attempt was made to change suit handling procedures, provide additional sterilization, or to limit typical potential contaminant sources. Using culture based techniques, we cultivated 235 CFU (colony forming units) comprised of 26 bacterial species and one fungal species on the outside of the suits. The fungal species and 14 of the bacterial species were unique to the suit surfaces and were not detected in any of the background samples collected within the chambers. We sequenced 755,434 ribosomal fragments on all of the suit surfaces from swab samples. 557,016 of these sequences represent DNA that survived at least 4 hours at vacuum. These sequences formed 2,464 OTU's (Operational Taxonomic Units, 97% similarity) showing low diversity in the samples. The most abundant sequences that survived vacuum belong to the genera Staphyloccocus, Ralstona, Bacillus and Rhodobacter all of which are common to the human microbiome. [5] See Danko et al., (2021) for more complete details of these first analyses. Further analysis of EVA suit materials with respect to the efficacy of various cleaning protocols and engineered containment solutions is planned to inform suit design for NASA’s Artemis Moon to Mars program crew testing. Swab Tool Function Results: The kit was demonstrated for fit and function in suited subject vacuum tests to determine how well the tool worked as an aseptic microbial sampling device as well as to identify any design elements that could be upgraded for EVA task specific improvement. It was found that sample acquisition efficacy could be enhanced by redesign of the sample canister to end-effector interface. Several modifications of the sample caddy assemblies to optimize EVA safety and functionality were also identified. Consequently, fabrication of the redesigned sample canister to end-effector assembly interfaces and and the sample caddy assemblies are required. Fabrication of sixteen flight sample canister assemblies (8 per each of two EVA Swab Kits) and two sample caddy assemblies are in process to be followed by hardware testing and certification to produce two flight-certified EVA Swab Kits for transport to ISS no earlier than summer of 2022. Sampling Strategy: The International Space Station is an ideal testbed for systematic studies of contamination from crewed vehicles since it has been continuously occupied for 20 years and exposed to non-terrestrial conditions. We will sample the exterior of the ISS during EVA using a purpose-built swab tool capable of maintaining sterility while undergoing temperature changes from -151 to +121°C under hard vacuum. Prior to each EVA, the project team will work with ISS mission managers to identify precise sampling locations, which will vary by EVA based on the translation paths and worksites scheduled for that particular EVA. Ideally, translation path handrails and areas near ECLSS (Environmental Control and Life Support System) external vent openings on a spacecraft would be assessed. There are currently more than a dozen ECLSS external vents on the ISS. Some are connected to systems that vent waste products, while others are intended to equalize cabin pressure. As EVA opportunity allows, microbial samples from any of these external vents would provide a valuable data point, though some will be more useful than others. Four criteria have been identified to help prioritize sampling sites near vents: • EVA Accessibility: To minimize cost, it is desired to piggy-back onto a planned EVA. Therefore, the sampling location must be readily accessible by an EVA crew • Type of Vented Products: Vent products that have been in direct contact with crew, such as cabin air, are more likely to contain microorganisms than vent products associated with isolated systems, such as experiment module combustion products. • Mass of Vented Products: Higher-flow vents are more likely to contain detectible levels of microbial contaminants than lower-flow vents. • Local Environment: Sample locations with relatively benign local conditions, such as warm surfaces shielded from direct ultraviolet (UV) radiation exposure, may be more likely to support microbial growth than locations with harsher local environmental conditions. Because EVA accessibility is the most important criteria, the proposal team worked with an astronaut and flight controllers using the Dynamic Onboard Ubiquitous Graphics (DOUG) tool. The DOUG virtual environment allows an operator to “fly” around the current ISS vehicle configuration to assess EVA translation paths, attach points, and keep-out zones. While analysis on station or rapid return to Earth would be preferable, samples collected from the exterior of the ISS have already been exposed to temperature variations between -157 and +121 °C as well as hard vacuum. Therefore, they should be fairly stable and robust. We hypothesize that samples collected from the ISS exterior could be stored for up to 6 months at -80°C without degradation. Sample canisters will be returned to Earth while frozen at -80°C for analysis, and sterilized canisters can be re-flown back to ISS to support additional sampling opportunities Relevance to NASA Exploration Objectives: These data will allow us to identify new or improved methods, technologies, and procedures for spacecraft sterilization and leakage mitigation to minimize the amount of contamination introduced to the environment by human explorers. This work is funded by NASA research grant: NNH18ZDA001N-PPR References: [1] Bell, M.S. et al. (2015) LPS XLVI, Abst. #1832 [2] Rucker et al. (2018) 42nd COSPAR (PPP.3) [3] Bell, M.S. et al. (2019) Mars Extant Life Conference, Abst. #5096.[4] Bell, M.S. et al., (2020) 43rd COSPAR (BO.2).[5] Danko D, et.al.,(2021)Front.Microbiol.12:608478.
The 2015 Sensorimotor Risk Standing Review Panel (from here on referred to as the SRP) participated in a WebEx/teleconference with members of the Human Health Countermeasures (HHC) Element, representatives from the Human Research Program (HRP), NASA Headquarters, and NASA Research and Education Support Services (NRESS) on December 17, 2015 (list of participants is in Section VI of this report). The SRP reviewed the new Evidence Report for the Risk of Impaired Control of Spacecraft/Associated Systems and Decreased Mobility Due to Vestibular/Sensorimotor Alterations Associated with Spaceflight (from here on referred to as the 2015 Sensorimotor Evidence Report), and also received a status review of the Risk. The opening section of the 2015 Sensorimotor Evidence Report provides written descriptions of various incidents that have occurred during space missions. In most of these incidents, the main underlying contributing factors are not easy to identify unambiguously. For example, in section 1.9, a number of falls occurred while astronauts were walking on the moon. It is not clear to the SRP, however, why they fell. It is only possible to extrapolate from likely specific psychophysical or physiological abnormalities, but how these abnormalities were determined, and how they were directly responsible for the falls is unclear to the SRP. Section 2.1.2 on proprioception is very interesting, but the functional significance of the abnormalities detected is not clear. The SRP sees this as a problem throughout the report: a mapping between the component abnormalities identified and the holistic behaviors that are most relevant, for example, controlling the vehicle, and locomotion during egress, is generally lacking. The SRP thinks the cognitive section is too strongly focused on vestibular functioning. The SRP questions the notion that the main cognitive effects are mainly attributable to reversible vestibular changes induced by spaceflight. The SRP thinks that there can also be independent cognitive effects. The Functional Task Test (FTT) protocols and the Field Test are particularly valuable. The conclusion is that the unloading of major postural muscles experienced during spaceflight plays a central role in the alteration of functional task performance and balance control. This conclusion stands in contrast with the statements in other parts of the document that emphasize the role of vestibular changes on these functions. It would help to more fully integrate these two views on the predominant effects of spaceflight. Although the SRP thinks the countermeasures section is interesting, the proposed countermeasures are not well integrated with the abnormalities described in previous sections. The SRP thinks it would help enormously to have explicit links among each abnormality, its 2015 Sensorimotor Risk SRP Evidence Review Final Report 2 overall importance/impact on function, and the appropriate countermeasure that can be implemented to maintain adequate functioning.