Search NASASearch

SEARCH · Search NASA

Results for “hydrogen fuel cell vehicle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

966 records · Page 29

Battery Failure Databank

The Battery Failure Databank contains thermal runaway results gathered from nearly 300 small format fractional thermal runaway calorimetry (S-FTRC) experiments. A majority of these experiments were conducted at synchrotron facilities where high-speed x-ray videography was conducted of the cell while tested inside of the S-FTRC. The databank is a two-component system which consists of a Microsoft ExcelTM spreadsheet which provides S-FTRC results in tabular format and a radiographic video library containing the high-speed x-ray videos. Overall, the databank provides thermal results from S-FTRC experiments conducted on a mixture of commercially available lithium-ion (Li-ion) cells and specialized Li-ion test cells with varying cell format (18650, 21700, and D-cell) and trigger mechanism (heaters, heaters plus internal short circuiting device, and nail penetration). The radiography video component provides insight into the initiation and propagation of TR in the cells, in addition to consequences of TR measured by the FTRC. Fractions of mass ejected for the cell types are separated into regimes based on the different failure modes of the cells, such as purely venting, partial ejection, and total ejection. With knowledge of the rate and characterization of the internal degradation of the cells during TR, and the amounts of mass ejected and unrecovered, the extent of TR, and therefore the mitigation of TR, is revealed relative to cell types and failure modes.

Lithium-ion battery

Recommendations for Establishing Local Rural Electrification Programs Using Photovoltaic Systems [Recomendaciones Para la Implantacidn de Programas Locales de Electrificacidn Rural con Sistemas Fotovoltaicos]

Photovoltaic (PV) technology is becoming one the best options for supplying electricity to rural communities far from electrical networks and which have a small and disperse demand for electricity. As the cost of the technology goes down and its development advances, opportunities for applying it continue to grow. As a result, in the near future we will probably see an increase in massive application programs of this technology in rural Mexico. This document presents some of the most relevant problems needing immediate solution to increase the possibility of success in establishing photovoltaic programs for rural electrification in Mexico. These problems are influenced by economic, technological, engineering, infrastructural, social and political issues. The paper presents the requirements for an industrial center based on PV technology, the accessibility of replacement parts and maintenance service, development of financial solutions, training of the users and introducing norms and technical regulations. The document summarizes the issue of rural electrification in Mexico, emphasizing the low population density in these areas. A brief description is given of photovoltaics showing different configurations that can be utilized for supplying electricity to the rural areas. The issues involved and recommendations for introducing PV systems to the rural area are described.

14 SOLAR ENERGY

Unraveling interphase-driven failure pathways in LiMn0.6Fe0.4PO4/graphite pouch cells

LiMnxFe1−xPO4 (LMFP) is a promising high-voltage, thermally stable, and earth-abundant cathode material, yet its practical application is limited by interphase instability and Mn dissolution. In this work, we systematically evaluate LiMn0.6Fe0.4PO4/graphite pouch cells using three electrolyte formulations including control carbonate electrolyte, control + 2 wt% vinylene carbonate (VC), and control + 2 wt% VC + 1 wt% 1,3,2-dioxathiolane 2,2-dioxide (DTD), to establish how electrolyte composition governs interphase chemistry and long-term degradation. Electrochemical testing shows that both additives are preferentially reduced prior to ethylene carbonate (EC) during cell formation, generating robust cathode-electrolyte interphase (CEI) and solid-electrolyte interphase (SEI) layers that suppress gas evolution and raise the first-cycle coulombic efficiency to 89.3%. Additionally, the dual-additive electrolyte delivers the most stable performance, retaining over 85% capacity after 600 cycles while minimizing impedance growth under long-term cycling at C/3 and 40 °C. Soft X-ray absorption spectroscopy confirms that VC + DTD effectively suppresses electrolyte oxidation at the cathode surface, and micro-X-ray fluorescence shows substantially reduced Mn dissolution and deposition on the graphite anode. Density functional theory simulations further provided insights into the structural and energetic influences of alkoxide species on the cathode surface, proposing a Mn2+ extraction mechanism. The combined experimental and computational findings establish a mechanistic link between electrolyte composition and interphase evolution, highlighting the effectiveness of electrolyte engineering for extending the operational lifetime of LMFP-based lithium-ion batteries.

Chak, Chanmonirath Michael

A 65 Ah rechargeable lithium molybdenum disulfide battery

A rechargeable lithium molybdenum disulfide battery which has a number of superior performance characteristics which includes a high energy density, a high power density, and a long charge retention time was developed. The first cell sizes developed included a C size cell and an AA size cell. Over the last two years, a project to demonstrate the feasibility of the scale up to this technology to a BC size cell with 65 Ah capacity was undertaken. The objective was to develop, build, and test a .6 kWh storage battery consisting of 6 BC cells in series.

Brandt, K.

Improvement of Odor Control for the UWMS Hard-Sided Fecal Canister and the Alternate Fecal Canister

On longer range exploration missions, the mass and volume of critical hardware and consumables required to support crew will pose a big stowage challenge. This includes the hardware for the collection and storage of human metabolic solid waste. The amount of stowage needed for this hardware both before (empty) and after (full) use will be a significant burden on the overall spacecraft habitable volume, layout, and design. To help with this challenge, the National Aeronautics and Space Administration (NASA) Mars Campaign Office (MCO) Logistics Reduction (LR) Portfolio has developed a collapsible canister for the collection and containment of fecal deposits. The Alternate Fecal Canister (AFC) is a collapsible alternative to the exploration toilet Hard-sided Fecal Canister (HFC). The AFC in its empty state has a volumetric benefit to smaller vehicles on longer missions. The current designs for HFC and AFC were tested with human fecal material for odor containment at White Sands Test Facility (WSTF) where the tests on both were unsuccessful. The source of the lack of containment was isolated to a gasket used on both HFC and AFC. The gasket used was found to be open cell in design. This paper provides a summary of the materials selection and testing process to identify a replacement gasket material with the intention to replace the gaskets on both existing units as well as incorporate it into the designs going forward for future builds for exploration. Details will be provided on the design of the canisters interface with the odor bacteria lid which led to the selection of the thickness of the desired replacement. Finally, the paper will provide an update on the testing in advance of a return to WSTF for final testing and detail plans to complete testing and perform a demonstration on ISS with UWMS.

ECLSS

Battery Charge Equalizer with Transformer Array

High-power batteries generally consist of a series connection of many cells or cell banks. In order to maintain high performance over battery life, it is desirable to keep the state of charge of all the cell banks equal. A method provides individual charging for battery cells in a large, high-voltage battery array with a minimum number of transformers while maintaining reasonable efficiency. This is designed to augment a simple highcurrent charger that supplies the main charge energy. The innovation will form part of a larger battery charge system. It consists of a transformer array connected to the battery array through rectification and filtering circuits. The transformer array is connected to a drive circuit and a timing and control circuit that allow individual battery cells or cell banks to be charged. The timing circuit and control circuit connect to a charge controller that uses battery instrumentation to determine which battery bank to charge. It is important to note that the innovation can charge an individual cell bank at the same time that the main battery charger is charging the high-voltage battery. The fact that the battery cell banks are at a non-zero voltage, and that they are all at similar voltages, can be used to allow charging of individual cell banks. A set of transformers can be connected with secondary windings in series to make weighted sums of the voltages on the primaries.

Davies, Francis

Safe, High Power/Voltage Battery Module Design Challenges

NASA seeks to demonstrate a path for achieving safe, high power, and high performing Li-ion battery designs for the purpose of establishing design guidelines for our aeronautic and spacecraft applications. Safe means passively resistant to thermal runaway propagation of any single cell catastrophic thermal runaway. High power means capable of 3C continuous discharge without overheating. High performing means achieving > 160 Wh/kg, 200 Wh/L. The biggest challenge has been balancing a high flux light weight path for cell heat dissipation during the high rate discharge that minimizes thermal gradients between cells and also protects adjacent cells from the heat load of thermal runaway cell. Our solution includes an oscillating heat pipe spine that contacts every 18650 cell in the pack and careful cell design selection to maximize the range of initial temperatures conditions where the battery can safely complete the 3C discharge.

Thermal runaway

The Role of Asparagine as a Gatekeeper Residue in the Selective Binding of Rare Earth Elements by Lanthanide‐Binding Peptides

Abstract Lanthanide‐binding tag (LBT) peptides selectively complex lanthanide cations (Ln 3+ ) in their binding pockets and are promising for lanthanide separation. However, designing LBTs that selectively target specific Ln 3+ cations remains a challenge due to limited molecular‐level understanding and control of interactions within the lanthanide‐binding pocket. In this study, we reveal that the N5 asparagine residue acts as a gatekeeper in the binding pocket, resulting in a 100‐fold selectivity for smaller Lu 3+ over larger La 3+ cations. Nuclear magnetic resonance spectroscopy and molecular dynamics simulations show that the N5 residue weakly binds to the larger La 3+ cation, permitting H 2 O molecules inside the pocket. For the smaller Lu 3+ cations, the N5 residue forms an inter‐arm hydrogen bond with the E14 glutamic acid residue, locking the Lu 3+ cation in the pocket and preventing H 2 O infiltration. Mutating the N5 asparagine to a D5 aspartic acid prevents such a hydrogen bond, eliminating the gatekeeping mechanism and precipitously reducing selectivity. The resulting binding affinity to Ln 3+ cations is non‐monotonic but generally increases with cation size. These results suggest a molecular design paradigm: the reduced affinity for larger lanthanides is due to open pocket conformations, while the selectivity of smaller Ln 3+ cations over larger ones is due to the gatekeeping hydrogen bond.

Chemistry

An Improved Theoretical Ni-Cd Battery Performance Model

Previous reports have shown how a battery model was developed using porous electrode theory. Since then the model has been upgraded and expanded. These upgrades include oxygen reation and positive electrode intercalation and proton diffusion. The effects of additional details of the solid state physics of the nickel electrode will be reported here.

battery

Enhancing Battery Safety with Fractional Thermal Runaway Calorimetry

Effective thermal management systems, designed to handle the impacts of thermal runaway (TR) and to prevent cell-to-cell propagation, are key to safe operation of lithium-ion (Li-ion) battery assemblies. Critical factors for optimising these systems include the total energy released during a single cell TR event and the fraction of the total energy that is released through the cell casing versus through the ejecta material. A unique fractional thermal runaway calorimeter (FTRC), designed to characterise said critical factors, was utilised to examine the TR behaviour of Li-ion cells). Delegates will be provided with an in-depth discussion on what fractional thermal runaway calorimetry is and how it benefits the development of safe and optimised battery assemblies that protect against thermal runaway. Delegates will see calorimetry data associated with a variety of Li-ion cells. Data presented is relevant to any industry that utilises high-energy Li-ion cells in closed environments and has a need to focus on safety.

Walker, William

Developing affordable and efficient heating devices for enhanced live cell imaging in confocal microscopy

Temperature control is crucial for live cell imaging, particularly in studies involving plant responses to high ambient temperatures and thermal stress. This study presents the design, development, and testing of two cost-effective heating devices tailored for confocal microscopy applications: an aluminum heat plate and a wireless mini-heater. The aluminum heat plate, engineered to integrate seamlessly with the standard 160 mm × 110 mm microscope stage, supports temperatures up to 36°C, suitable for studies in the range of non-stressful warm temperatures (e.g., 25-27°C forArabidopsis thaliana) and moderate heat stress (e.g., 30-36°C forA. thaliana). We also developed a wireless mini-heater that offers rapid, precise heating directly at the sample slide, with a temperature increase rate over 30 times faster than the heat plate. The wireless heater effectively maintained target temperatures up to 50°C, ideal for investigating severe heat stress and heat shock responses in plants. Both devices performed well in controlled studies, including the real-time analysis of heat shock protein accumulation and stress granule formation inA. thaliana. Our designs are effective and affordable, with total construction costs lower than $300. This accessibility makes them particularly valuable for small laboratories with limited funding. Future improvements could include enhanced heat uniformity, humidity control to mitigate evaporation, and more robust thermal management to minimize focus drift during extended imaging sessions. These modifications would further solidify the utility of our heating devices in live cell imaging, offering researchers reliable, budget-friendly tools for exploring plant thermal biology.

Plant Sciences

Technology Demonstrator of an Americium-Fuelled Radioisotope Stirling Generator

Americium-241 is used as the fuel of choice in European Radioisotope Power Systems. The University of Leicester have developed a number of systems using this fuel type, including a 200 Wth heat source. To maximise the electrical output that can be generated from the heat source, the University of Leicester and NASA Glenn Research Center have collaborated on a radioisotope Stirling generator concept, building on the long heritage of dynamic power conversion developments at NASA GRC. Here we present the design of a technology demonstrator of the Americium-fuelled Radioisotope Stirling Generator (Am-RSG).

Americium-241

Decoupling Failure Pathways in Li-O 2 Cells Operated Under Lean Electrolyte Conditions

The operation of lithium-oxygen (Li-O 2 ) batteries under lean electrolyte conditions offers higher energy density but leads to rapid degradation and short cycle life. Although cathode passivation and electrolyte decomposition occur in all regimes, we show that under lean electrolyte conditions, failure is primarily driven by progressive electrolyte consumption at the lithium/solid electrolyte interphase (SEI), rather than by irreversible cathode passivation. Poor wetting of the lithium surface results in heterogeneous SEI growth and high local current densities, which accelerate electrolyte loss and cell failure. Strategies aimed at improving interfacial stability, including optimized wetting and SEI forming additives, significantly extend cycle life without compromising energy density. Our results establish anode-electrolyte interactions as the dominant degradation mechanism under lean electrolyte conditions, and emphasize the need to engineer a stable Li/SEI interface for long-lasting Li-O 2 batteries.

Córdoba, Daniel [Argonne National Laboratory (ANL)

Space Shuttle News Reference

A detailed description of the space shuttle vehicle and associated subsystems is given. Space transportation system propulsion, power generation, environmental control and life support system and avionics are among the topics. Also, orbiter crew accommodations and equipment, mission operations and support, and flight crew complement and crew training are addressed.

National Aeronautics and Space Administration

Ares I-X Ground Diagnostic Prototype

Automating prelaunch diagnostics for launch vehicles offers three potential benefits. First, it potentially improves safety by detecting faults that might otherwise have been missed so that they can be corrected before launch. Second, it potentially reduces launch delays by more quickly diagnosing the cause of anomalies that occur during prelaunch processing. Reducing launch delays will be critical to the success of NASA's planned future missions that require in-orbit rendezvous. Third, it potentially reduces costs by reducing both launch delays and the number of people needed to monitor the prelaunch process. NASA is currently developing the Ares I launch vehicle to bring the Orion capsule and its crew of four astronauts to low-earth orbit on their way to the moon. Ares I-X will be the first unmanned test flight of Ares I. It is scheduled to launch on October 27, 2009. The Ares I-X Ground Diagnostic Prototype is a prototype ground diagnostic system that will provide anomaly detection, fault detection, fault isolation, and diagnostics for the Ares I-X first-stage thrust vector control (TVC) and for the associated ground hydraulics while it is in the Vehicle Assembly Building (VAB) at John F. Kennedy Space Center (KSC) and on the launch pad. It will serve as a prototype for a future operational ground diagnostic system for Ares I. The prototype combines three existing diagnostic tools. The first tool, TEAMS (Testability Engineering and Maintenance System), is a model-based tool that is commercially produced by Qualtech Systems, Inc. It uses a qualitative model of failure propagation to perform fault isolation and diagnostics. We adapted an existing TEAMS model of the TVC to use for diagnostics and developed a TEAMS model of the ground hydraulics. The second tool, Spacecraft Health Inference Engine (SHINE), is a rule-based expert system developed at the NASA Jet Propulsion Laboratory. We developed SHINE rules for fault detection and mode identification. The prototype uses the outputs of SHINE as inputs to TEAMS. The third tool, the Inductive Monitoring System (IMS), is an anomaly detection tool developed at NASA Ames Research Center and is currently used to monitor the International Space Station Control Moment Gyroscopes. IMS automatically "learns" a model of historical nominal data in the form of a set of clusters and signals an alarm when new data fails to match this model. IMS offers the potential to detect faults that have not been modeled. The three tools have been integrated and deployed to Hangar AE at KSC where they interface with live data from the Ares I-X vehicle and from the ground hydraulics. The outputs of the tools are displayed on a console in Hangar AE, one of the locations from which the Ares I-X launch will be monitored. In a previous publication, we discussed how we selected the three tools based primarily on their ability to be certified for human spaceflight and described our plans for the prototype. This abstract is due October 23, 2009, and the Ares I-X launch is currently scheduled for October 27, 2009. If this abstract is accepted, then the full paper will describe how the prototype performed before the launch. It will include an analysis of the prototype's accuracy, including false-positive rates, false-negative rates, and receiver operating characteristics (ROC) curves. It will also include a description of the prototype's computational requirements, including CPU usage, main memory usage, and disk usage. If the prototype detects any faults during the prelaunch period then the paper will include a description of those faults. Similarly, if the prototype has any false alarms then the paper will describe them and will attempt to explain their causes. Also, the paper will describe the three tools and how they are used in the prototype. It will include a description of the TEAMS models of the Ares I-X first-stage TVC and associated ground hydraulics and how we adapted the TVC model for use in real-time diagnostics. It will describe the SHINE rules used for fault detection and mode identification and the software architecture that interfaces the various pieces of existing software that are part of the prototype to one another. It will describe how we selected the sensor values and commands that were used to train the IMS model and how we optimized the number of clusters in the IMS model. It will include screen shots of the graphical display that we developed in Java to display the outputs of the three tools. Because Ares I-X data was not yet available to us while we were developing the prototype, we used historical data from the Space Shuttle's Solid Rocket Booster (SRB) TVCs and the associated ground hydraulics to train IMS and to test the entire prototype. Because most of the failure modes that we modeled have never occurred in the Shuttle we inserted simulated failures into the Shuttle data. The Ares I-X first-stage TVC is very similar to the SRB TVC and we expect the data will be very similar. After the launch, we will determine how similar the data actually is and report how any differences in the data affected the diagnostic accuracy of the prototype. Finally, although we did not get the prototype certified, we designed it in a way that it could be certified and wrote a preliminary certification plan. The paper will include a brief summary of how we considered the need for certification in the design of the prototype, how we tested the prototype before deploying it to Hangar AE, and how we would propose to get it certified if it were deployed as an operational system. The paper will conclude with a description of some of the challenges we faced and some of the lessons learned in developing and deploying the prototype.

International Space Station

The 1975 GSFC Battery Workshop

The proceedings of the 1975 Goddard Space Flight Center Battery Workshop are presented. The major topics of discussion were nickel cadmium batteries and, to a lesser extent, nickel hydrogen batteries. Battery design, manufacturing techniques, testing programs, and electrochemical characteristics were considered. The utilization of these batteries for spacecraft power supplies was given particular attention.

Source record