Photoconductive switch package configurations having a profiled resistive element

Methods, systems, and devices are disclosed for photoconductive switch package configurations. In some aspects, a photoconductive switch package includes of a wide bandgap photoconductive material (e.g., GaN, ZnO, diamond, AlN, SiC, BN, etc.), a source for energetic photons (e.g., a laser), a mechanism to couple the laser into the switch, and a mechanism for high voltage to enter and leave the switch package. In some implementations, the disclosed photoconductive switch packages can be configured as a three terminal device, e.g., similar to transistors, with one of the terminals being laser input or the voltage input to the laser system.

42 ENGINEERING↗

Investigation of instrumentation containing an embedded digital device - 257

The U.S. nuclear power industry primarily relies on mature, well-proven analog technology as the basis for most instrumentation and control (I and C) equipment employed in its nuclear power plants (NPPs). However, the market for this legacy instrumentation is very small and availability of such equipment for spare parts or replacement is increasingly limited. Frequently, modern I and C equipment contains embedded digital devices (EDDs), such as microprocessors and programmable logic devices. While the enhanced functional capabilities provided by the digital components offer improved performance, reliability, and maintainability, the corresponding complexity of sophisticated digital implementations also exacerbate concerns about an increased potential for undetected systematic faults, which can lead to common-cause failure (CCF). As part of a research project sponsored by the U.S. Department of Energy, an investigation has been conducted of commercially available instrumentation marketed for nuclear or industrial application. The objective was to identify the usage of EDDs and to determine the types of functional roles allocated to the devices. Examples of the equipment surveyed include smart sensors, sequencers for emergency diesel generators, pumps, valve actuators, motor control centers, breakers, priority logic modules, and uninterruptible power sources. Where sufficient detail was found, an evaluation was performed to ascertain the nature and role of the digital technology implemented in the instrumentation. The information gained through this investigation serves as technical input for defining a classification approach for EDDs based on the functional impact of the device. For example, the role of an EDD can involve any of the following functions: performance monitoring and diagnostics, information extraction and communication, instrument condition monitoring and protection, or execution of core instrument functions. Classifying digital devices according to their role in the operation of the instrumentation in which they are embedded can enable determination of the potential functional impact of failure of that device and contribute to determination of the potential safety significance of a CCF event disabling all instances of that device. This paper will report on the findings of the investigation of instrumentation with EDDs and indicate considerations for the emerging classification approach. The higher-level goal of this effort is to determine whether a graded approach to qualification testing may be possible based on classification. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Yield Analysis and Comparison of GaInP/Si and GaInP/GaAs Multi-Terminal Tandem Solar Cells

We present a yield analysis of tandem devices consisting of GaInP top cells on Si or GaAs bottom cells with different terminal configurations. Inputs are the I-V and external quantum efficiency of the individual subcells and the irradiance-dependent module temperature of the bottom cell. Our model calculates the temperature of the tandem module by taking into account the performance, spectral working range and luminescent coupling of the different tandem devices, enabling an irradiance- and weather-dependent yield analysis for these modules. We apply the model to compare two types of two junction devices, a GaInP/GaAs monolithically grown tandem device, and a GaInP top cell stacked on a Si bottom cell, the present two best dual junction devices. When the subcells are series connected both technologies perform equally well. The performance of the GaInP/Si can be significantly improved relatively by 5.8% using 3-terminal (3T) devices with a back-contacted bottom cell instead of a 2T configuration, showing a possible benefit when using Si back contacted cells. For GaInP/Si, the 3T-device works as well as the 4T-device, enabling the integration of monolithic tandem cells into modules at comparably high efficiencies.

14 SOLAR ENERGY↗

Laser Welding in Electronic Packaging

The laser has proven its worth in numerous high reliability electronic packaging applications ranging from medical to missile electronics. In particular, the pulsed YAG laser is an extremely flexible and versatile too] capable of hermetically sealing microelectronics packages containing sensitive components without damaging them. This paper presents an overview of details that must be considered for successful use of laser welding when addressing electronic package sealing. These include; metallurgical considerations such as alloy and plating selection, weld joint configuration, design of optics, use of protective gases and control of thermal distortions. The primary limitations on use of laser welding electronic for packaging applications are economic ones. The laser itself is a relatively costly device when compared to competing welding equipment. Further, the cost of consumables and repairs can be significant. These facts have relegated laser welding to use only where it presents a distinct quality or reliability advantages over other techniques of electronic package sealing. Because of the unique noncontact and low heat inputs characteristics of laser welding, it is an ideal candidate for sealing electronic packages containing MEMS devices (microelectromechanical systems). This paper addresses how the unique advantages of the pulsed YAG laser can be used to simplify MEMS packaging and deliver a product of improved quality.

Source record↗

Interfacial Band-Edge Energetic Control

Direct photoelectrochemical water splitting offers a sustainable way to produce carbon-neutral solar fuels in a potentially cost-efficient and scalable way. To date, many devices have been developed to achieve overall water splitting using only solar irradiation as the energy input. Most of these systems are made from semiconductor photoelectrodes, which are used to absorb light, separate photogenerated charge carriers, and perform catalysis. Significant overpotentials for catalysis are formed by the difference in the energy band levels of the semiconductors (and associated electrocatalysts) that determine the overall efficiency of these devices. Therefore it is critical to understand how these energetics of photoelectrodes interact with the electrolyte, and with each other in semiconductor/semiconductor, and semiconductor-metal junctions. This document aims to summarize the highest performing solar water splitting devices reported in literature, in the context of these interfaces energetic interfaces.

08 HYDROGEN↗

Electrolytic gold plating, stripping, and ion transport dynamics through a solid-state iodide perovskite

The pronounced electrochemical reactivity between halide perovskites and metal electrodes can introduce mobile extrinsic metal ions which can cause device instability or enable novel functionalities. Here we systematically investigate the kinetics of gold cation (Au + ) migration in indium tin oxide (ITO)/methylammonium lead triiodide (MAPbI 3 )/Au model devices under long-term potentiostatic biasing. Scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and density functional theory (DFT) analyses reveal that Au + ions, electrochemically generated at the Au anode, traverse the perovskite layer with diffusion coefficients on the order of 10 −11 to 10 −10 cm 2 s −1 and are subsequently reduced at the cathode as Au 0 clusters, resembling metal plating behavior in electrolytic cells and solid-state batteries during charging. Furthermore, reversing the applied bias strips the plated Au 0 , revealing reversibility suitable for bipolar resistive switching devices and providing direct evidence of the electrochemical and ionic nature of Au transport within the perovskite matrix. Quantitatively determining diffusion coefficients and ion concentrations provides foundational inputs for future drift-diffusion modelling opportunities and allows us to relate our findings to implications on long term operation of devices like photovoltaic modules. These results clearly demonstrate the solid-state electrochemical nature of perovskite devices, highlight methods to be more quantitative about ion transport properties, provide and emphasize the importance of disentangling electro-, photo-, photoelectrochemical processes for understanding device performance and unlocking new functionalities.

14 SOLAR ENERGY↗

Microchannel spatial light modulator

The Microchannel Spatial Light Modulator (MSLM), a versatile, highly sensitive, and optically addressed device being developed for real time optical information processing is discussed. The MSLM operates by converting an input optical image into a charge distribution at the surface of an electro-optic crystal. The charge distribution generates an electric field which modulates the refractive index of the crystal and thereby the phase or intensity of an image readout beam. Prototype devices employing 250 micron thick crystals exhibited a spatial resolution of 5 cycles/mm at 50% contrast, an exposure sensitivity of 2.2 nJ/cu cm and framing rates of 40 Hz with full modulation depth. The image processing operations that have been achieved using the internal processing mode of the MSLM include contrast reversal, contrast enhancement, edge enhancement, image addition and subtraction, analog and digital intensity thresholding, and binary level logic operations such as AND, OR, EXCLUSIVE OR, and NOR.

Warde, C.↗

Transient Voltage Recorder

A voltage transient recorder can detect lightning induced transient voltages. The recorder detects a lightning induced transient voltage and adjusts input amplifiers to accurately record transient voltage magnitudes. The recorder stores voltage data from numerous monitored channels, or devices. The data is time stamped and can be output in real time, or stored for later retrieval. The transient recorder, in one embodiment, includes an analog-to-digital converter and a voltage threshold detector. When an input voltage exceeds a pre-determined voltage threshold, the recorder stores the incoming voltage magnitude and time of arrival. The recorder also determines if its input amplifier circuits clip the incoming signal or if the incoming signal is too low. If the input data is clipped or too low, the recorder adjusts the gain of the amplifier circuits to accurately acquire subsequent components of the lightning induced transients.

Pedro J Medelius↗

Solutions to time variant problems of real-time expert systems

Real-time expert systems for monitoring and control are driven by input data which changes with time. One of the subtle problems of this field is the propagation of time variant problems from rule to rule. This propagation problem is even complicated under a multiprogramming environment where the expert system may issue test commands to the system to get data and to access time consuming devices to retrieve data for concurrent reasoning. Two approaches are used to handle the flood of input data. Snapshots can be taken to freeze the system from time to time. The expert system treats the system as a stationary one and traces changes by comparing consecutive snapshots. In the other approach, when an input is available, the rules associated with it are evaluated. For both approaches, if the premise condition of a fired rule is changed to being false, the downstream rules should be deactivated. If the status change is due to disappearance of a transient problem, actions taken by the fired downstream rules which are no longer true may need to be undone. If a downstream rule is being evaluated, it should not be fired. Three mechanisms for solving this problem are discussed: tracing, backward checking, and censor setting. In the forward tracing mechanism, when the premise conditions of a fired rule become false, the premise conditions of downstream rules which have been fired or are being evaluated due to the firing of that rule are reevaluated. A tree with its root at the rule being deactivated is traversed. In the backward checking mechanism, when a rule is being fired, the expert system checks back on the premise conditions of the upstream rules that result in evaluation of the rule to see whether it should be fired. The root of the tree being traversed is the rule being fired. In the censor setting mechanism, when a rule is to be evaluated, a censor is constructed based on the premise conditions of the upstream rules and the censor is evaluated just before the rule is fired. Unlike the backward checking mechanism, this one does not search the upstream rules. This paper explores the details of implementation of the three mechanisms.

Yeh, Show-Way↗

Detecting defects that reduce breakdown voltage using machine learning and optical profilometry

Abstract Semiconductor wafer manufacturing relies on the precise control of various performance metrics to ensure the quality and reliability of integrated circuits. In particular, GaN has properties that are advantageous for high voltage and high frequency power devices; however, defects in the substrate growth and manufacturing are preventing vertical devices from performing optimally. This paper explores the application of machine learning techniques utilizing data obtained from optical profilometry as input variables to predict the probability of a wafer meeting performance metrics, specifically the breakdown voltage (V bk ). By incorporating machine learning techniques, it is possible to reliably predict performance metrics that cause devices to fail at low voltage. For diodes that fail at a higher (but still below theoretical) breakdown voltage, alternative inspection methods or a combination of several experimental techniques may be necessary.

42 ENGINEERING↗

Gated-Viewing System with an Electronic Shutter on a CCD Image Sensor

The results of the development and experimental investigation of the gated-viewing method without the using an image intensifier as a fast shutter are presented. The device for implementing the method consists of an interline CCD image sensor with an input lens and 906 nm pulsed laser diode with an output lens that forms an illumination beam. The gated-viewing method is based on the original CCD control procedure, which allows observing multiple pulses without lowering the frame rate. Experimental studies have shown the method feasibility under conditions of smoke and fog.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Portable Intravenous Fluid Production Device For Ground Use Project

Several medical conditions require the administration of intravenous (IV) fluids,but limitations of mass, volume, shelf-life, transportation, and local resources can restrict the availability of these important fluids. Such limitations are expected in long-duration space exploration missions and in remote or austere places on Earth. This design uses regular drinking water that is pumped through two filters to produce, in minutes, sterile, ultrapure water that meets the stringent quality standards of the United States Pharmacopeia for Water for Injection (Total Bacteria, Conductivity, Endo - toxins, Total Organic Carbon). The device weighs 2.2 lb (1 kg) and is 10 in. long, 5 in. wide, and 3 in. high (≈25, 13, and 7.5 cm, respectively) in its storage configuration. This handheld device produces one liter of medical-grade water in 21 minutes. Total production capacity for this innovation is expected to be in the hundreds of liters. The device contains one battery powered electric mini-pump. Alternatively, a manually powered pump can be attached and used. Drinking water enters the device from a source water bag, flows through two filters, and final sterile production water exits into a sealed, medical-grade collection bag. The collection bag contains pre-placed crystalline salts to mix with product water to form isotonic intravenous medical solutions. Alternatively, a hypertonic salt solution can be injected into a filled bag. The filled collection bag is detached from the device and is ready for use or storage. This device currently contains one collection bag, but a manifold of several pre-attached bags or replacement of single collection bags under sterile needle technique is possible for the production of multiple liters. The entire system will be flushed, sealed, and radiation-sterilized. Operation of the device is easy and requires minimal training. Drinking water is placed into the collection bag. Inline stopcock flow valves at the source and collection bags are opened, and the mini-pump is turned on by a switch to begin fluid flow. When the collection bag is completely filled with the medical- grade water, the pump can be turned off. The pump is designed so it cannot pump air, and overfilling of the collection bag with fluid is avoided by placing an equal amount of water in the source bag. Backflow is avoided by inline check valves. The filled collection bag is disconnected from its tubing and is ready for use. The source bag can be refilled for production of multiple liters, or the source bag can be replaced with an input tube that can be placed in a larger potable water source if the device is attended. The device functions in all orientations independent of any gravity fields. In addition to creating IV fluids, the device produces medical-grade water, which can be used for mixing with medications for injection, reconstituting freeze-dried blood products for injection, or for wound hydration or irrigation. Potential worldwide use is expected with medical activities in environments that have limited resources, storage, or resupply such as in military field operations, humanitarian relief efforts, submarines, commercial cruise ships, etc.

Technology Portfolio System↗

Pioneer Design of Non-contact Synchronized Measurement Devices Using Electric and Magnetic Field Sensors

Here, traditional synchrophasors rely on CTs and PTs physically connected to transmission lines or buses to acquire input signals for phasor measurement. However, it is challenging to install and maintain traditional phasor measurement units in some remote areas due to lack of facilities. Since transmission lines naturally generate alternating electrical and magnetic fields in the surrounding atmosphere, this paper presents two innovative designs for non-contact synchronized measurement devices (NCSMD), including an electric field sensor based non-contact SMD (E-NCSMD) and a magnetic field sensor based non-contact SMD (M-NCSMD). Compared with conventional synchrophasors, E-NCSMD and M-NCSMD are much more flexible to be deployed and have much lower costs, making E-NCSMDs and M-NCSMD highly accessible and useful for a wide array of phasor measurement applications. Laboratory and field experiment results verified the effectiveness of the designs of both E-NCSMD and M-NCSMD.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On a photon-counting array using the Fairchild CCD-201

The evaluation of certain performance parameters of the Fairchild CCD 201 and the proposed method of operation of an electron bombarded charge coupled device are described. Work in progress on the evaluation of the parameters relevant to remote, low noise operation is reported. These tests have been conducted using light input. The video data from the CCD are amplified, digitized, stored in a minicomputer memory, and then recorded on magnetic tape for analyzing. The device will be used in an array of sensors in the aperture plane of a telescope to discriminate between photoelectron events, and in the focal plane operating at single photoelectron sensitivity at a minimum of blooming and lag.

Currie, D. G.↗

High-frequency wattage-to-voltage converter

Solid state device, which measures electric power over a wide frequency range, multiplies two electrical input signals to produce an output voltage that is proportional to their product. Quarter-square type of electronic analog multiplier is used.

Vrancik, J. E.↗

Thermoelectric thin film thermal coating systems

Derivation of the fluid loop temperature profile for a model with thermoelectric devices (TED) attached is developed as a function of position, incident radiation intensity, input fluid loop temperature and TED current. The associated temperature of the radiator is also developed so that the temperature difference across the TED can be determined for each position. The temperature difference is used in determining optimum operating conditions and available generated electrical power.

Harpster, J. W.↗

The electrostatic storage tube

An electrostatic camera system is discussed which is based on the electrostatic storage tube. The development of the system was begun following a series of experiments which indicated that the device offers signficantly improved performance over currently available devices. The approach used in developing the high performance camera involves: converting the input image to an electron image at low loss, applying a low noise gain process, and storing the resulting charge pattern in a low-loss target. The basic processes and elements of the electrostatic storage tube are illustrated and discussed. Graphs that depict the camera performance characteristics are included.

Rutherford, R. E., Jr.↗

ATS-F spacecraft - An EMC challenge

The Applications Technology Satellite F (ATS-F) is the latest of a series of satellites for communications, scientific experiments, and data collection. The physical configuration of the spacecraft is examined along with operational characteristics and EMC management and control. Predicted and encountered problems are discussed, giving attention to wiring pick-up and reradiation, input rectification and bias off-set, intermodulation products, harmonics, component degradation, electroexplosive devices, spacecraft test complex vulnerability, and launch environment testing. Approaches used for locating the problems are considered and a description is given of the key factors and constraints in achieving EMC.

Kampinsky, A.↗