Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Argon metastable density and temperature of a 43 GHz microplasma

Argon (1s 5 ) metastable density and translational gas temperature are experimentally measured using laser diode absorption spectroscopy within a 43 GHz microplasma. The plasma is initiated and sustained within a photonic crystal constructed from a rectangular array of alumina rods, each 1 mm in diameter. This configuration generates stable microplasma from 10 to 600 Torr using millimeter wave power from 100 to 1200 mW. The metastable density is in the order of 10 18 m –3 at low pressure. However, Ar(1s 5 ) density decreases to undetectable levels with increasing pressure and wave power. The gas temperature is extracted from the Lorentzian line shape of the absorption profile at 811.53 nm. The gas temperature increases from approximately 400 K at low pressure to 2000 K at 320 Torr (427 mbar, 4.27 × 10 4 Pa). Furthermore, these data are compared with previous results and suggest that the microplasma has a dense core of electrons that depletes the metastable density at high gas pressure and wave power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Charged particle transport coefficient challenges in high energy density plasmas

High energy density physics (HEDP) and inertial confinement fusion (ICF) research typically relies on computational modeling using radiation-hydrodynamics codes in order to design experiments and understand their results. These tools, in turn, rely on numerous charged particle transport and relaxation coefficients to account for laser energy absorption, viscous dissipation, mass transport, thermal conduction, electrical conduction, non-local ion (including charged fusion product) transport, non-local electron transport, magnetohydrodynamics, multi-ion-species thermalization, and electron-ion equilibration. In many situations, these coefficients couple to other physics, such as imposed or self-generated magnetic fields. Furthermore, how these coefficients combine are sensitive to plasma conditions as well as how materials are distributed within a computational cell. Uncertainties in these coefficients and how they couple to other physics could explain many of the discrepancies between simulation predictions and experimental results that persist in even the most detailed calculations. This paper reviews the challenges faced by radiation-hydrodynamics in predicting the results of HEDP and ICF experiments with regard to these and other physics models typically included in simulation codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pump-depletion dynamics and saturation of stimulated Brillouin scattering in shock ignition relevant experiments

As an alternative inertial confinement fusion scheme, shock ignition requires a strong converging shock driven by a high-intensity laser pulse to ignite a pre-compressed fusion capsule. Understanding nonlinear laser-plasma instabilities is crucial to assess and improve the laser-shock energy coupling. Recent experiments conducted on the OMEGA EP laser facility have for the first time demonstrated that such instabilities can 100% deplete the first 0.5 ns of the high-intensity laser. Here, analyses of the observed laser-generated blast wave suggest that this pump-depletion starts at 0.02 critical density and progresses to 0.1-0.2 critical density, which is also confirmed by the time-resolved stimulated Raman backscattering spectra. The pump-depletion dynamics can be explained by the breaking of ion-acoustic waves in stimulated Brillouin scattering. Such pump-depletion would inhibit the collisional laser energy absorption but may benefit the generation of hot electrons with moderate temperatures for electron shock ignition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulse-burst spontaneous Raman thermometry of unsteady wave phenomena in a shock tube

A high-speed temperature diagnostic based on spontaneous Raman scattering (SRS) was demonstrated using a pulse-burst laser. The technique was first benchmarked in near-adiabatic H 2 -air flames at a data-acquisition rate of 5 kHz using an integrated pulse energy of 1.0 J per realization. Both the measurement precision and accuracy in the flame were within 3% of adiabatic predictions. Furthermore, this technique was then evaluated in a challenging free-piston shock tube environment operated at a shock Mach number of 3.5. SRS thermometry resolved the temperature in post-incident and post-reflected shock flows at a repetition rate of 3 kHz and clearly showed cooling associated with driver expansion waves. Collectively, this Letter represents a major advancement for SRS in impulsive facilities, which had previously been limited to steady state regions or single-shot acquisition.

47 OTHER INSTRUMENTATION↗

Measurement of Magnetic Field using Doppler-Free Saturation Spectroscopy (DFSS) in C-2W FRC Plasma

The Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and TAE Technologies (TAE) focused on implementing an existing mobile Doppler-free saturation spectroscopy (DFSS) diagnostic to determine the direction of the equilibrium magnetic field within TAE’s C-2W field-reversed configuration (FRC) fusion device. Non-perturbative measurements of magnetic fields in the core of FRCs can provide critical information needed to constrain equilibrium models and for the continued advancement of the fusion research program at TAE. DFSS is a well-established, laser-based absorption spectroscopy technique used to suppress inhomogeneous (Doppler) broadening and reveal the Zeeman fine structure of the target emission lines. The collaboration involved the use of ORNL’s recently constructed mobile DFSS diagnostic. The DFSS diagnostic was shipped and installed on C- 2W in February 2023. TAE’s expertise was used to design and construct the mechanic support structures required to mount the optical hardware on C-2W. Additionally TAE provide critical input to minimize the noise imposed on the DFSS signal by vibrations of the mechanic support structure during operations. DFSS data was obtained for over 500 C-2W shots and will continue until the expiration of this CRADA on September 30 th 2023. Over the course of this work, significant progress was made to maximize the signal to noise (SNR) ratio. Analysis of recently acquired data is on-going, however, initial indications are highly suggestive that a DFSS signal above background has been successfully acquired in C-2W.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Relativistically Induced Transparency in Plasma (Final Research Report)

The major goal of this project was to study the process of relativistic transparency in plasmas. This process occurs when a very high intensity laser pulse interacts with a plasma. The electric field of the laser oscillates the electron speeds approaching the speed of light, increasing the effective mass of the electrons by the time-averaged Lorentz factor <γ>. The increase in the effective mass alters the critical density, the density at which the plasma becomes opaque to the electromagnetic wave of the laser. This project used experiments and particle-in-cell simulations to study this process in ultra-thin foil interactions. Experiments were performed through the LaserNetUS program on the Ohio State University laser system Scarlet. The transmitted and reflected light was studied as a function of the target thickness, the near-field profiles, the total energy and pulse duration were measured. Particle-in-cell simulations, using the OSIRIS code were used to model the interaction and better understand the dynamics. The results of both show current relativistic transparency theory is insufficient to predict the results, this is likely because the theories do not account for the laser energy absorption into the target and global plasma fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interactions of a Microdischarge with a Premixed Flame (Final Technical Report)

In this project we introduced an experimental platform that facilitates the study of the two-way interaction of plasma and flame, and the exploration of the impact of the spatial location of the discharge on its kinetics, in a controlled environment. The experimental platform is a mesoscale CH4/air premixed flame burner that also acts as a dielectric barrier discharge (DBD) operated by nanosecond pulsed voltage. A unique feature of this setup is that the DBD utilizes transparent electrodes, made of Indium Tin Oxide (ITO), to unlock optical access along the line-of-sight parallel to the dominant electric field. This platform is suitable to study both the forward problem (impact of plasma-on-flame), which manifests itself as a modified flame speed as well as flame wrinkling; and the backward problem (impact of flame-on-plasma), which includes plasma regime transitions, between microdischarges and uniform modes, driven by the flame passage. Prior work at MIT has focused on electrical measurements and direct imaging studies of the plasma-flame interaction through the ITO electrode. This project, which was awarded experimental runtime at the Low-temperature Plasma Research Facility (PRF) at Sandia National Laboratories, quantifies the flame-plasma interaction through temporally resolved measurement of key radicals (oxygen atom, O) produced by the nanosecond repetitively pused discharge (NRPD) in an individual microdischarge, using two-photon absorption laser-induced fluorescence (TALIF).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Standoff Infrared Measurements of Chemical Plume Dynamics in Complex Terrain Using a Combination of Active Swept-ECQCL Laser Spectroscopy with Passive Hyperspectral Imaging

Chemical plume detection and modeling in complex terrain present numerous challenges. We present experimental results from outdoor releases of two chemical tracers (sulfur hexafluoride and Freon-152a) from different locations in mountainous terrain. Chemical plumes were detected using two standoff instruments collocated at a distance of 1.5 km from the plume releases. A passive long-wave infrared hyperspectral imaging system was used to show time- and space-resolved plume transport in regions near the source. An active infrared swept-wavelength external cavity quantum cascade laser system was used in a standoff configuration to measure quantitative chemical column densities with high time resolution and high sensitivity along a single measurement path. Both instruments provided chemical-specific detection of the plumes and provided complementary information over different temporal and spatial scales. The results show highly variable plume propagation dynamics near the release points, strongly dependent on the local topography and winds. Effects of plume stagnation, plume splitting, and plume mixing were all observed and are explained based on local topographic and wind conditions. Measured plume column densities at distances ~100 m from the release point show temporal fluctuations over ~1 s time scales and spatial variations over ~1 m length scales. The results highlight the need for high-speed and spatially resolved measurement techniques to provide validation data at the relevant spatial and temporal scales required for high-fidelity terrain-aware microscale plume propagation models.

47 OTHER INSTRUMENTATION↗

Versatile soil gas concentration and isotope monitoring: optimization and integration of novel soil gas probes with online trace gas detection

Abstract. Gas concentrations and isotopic signatures can unveil microbial metabolisms and their responses to environmental changes in soil. Currently, few methods measure in situ soil trace gases such as the products of nitrogen and carbon cycling or volatile organic compounds (VOCs) that constrain microbial biochemical processes like nitrification, methanogenesis, respiration, and microbial communication. Versatile trace gas sampling systems that integrate soil probes with sensitive trace gas analyzers could fill this gap with in situ soil gas measurements that resolve spatial (centimeters) and temporal (minutes) patterns. We developed a system that integrates new porous and hydrophobic sintered polytetrafluoroethylene (sPTFE) diffusive soil gas probes that non-disruptively collect soil gas samples with a transfer system to direct gas from multiple probes to one or more central gas analyzer(s) such as laser and mass spectrometers. Here, we demonstrate the feasibility and versatility of this automated multiprobe system for soil gas measurements of isotopic ratios of nitrous oxide (δ18O, δ15N, and the 15N site preference of N2O), methane, carbon dioxide (δ13C), and VOCs. First, we used an inert silica matrix to challenge probe measurements under controlled gas conditions. By changing and controlling system flow parameters, including the probe flow rate, we optimized recovery of representative soil gas samples while reducing sampling artifacts on subsurface concentrations. Second, we used this system to provide a real-time window into the impact of environmental manipulation of irrigation and soil redox conditions on in situ N2O and VOC concentrations. Moreover, to reveal the dynamics in the stable isotope ratios of N2O (i.e., 14N14N16O, 14N15N16O, 15N14N16O, and 14N14N18O), we developed a new high-precision laser spectrometer with a reduced sample volume demand. Our integrated system – a tunable infrared laser direct absorption spectrometry (TILDAS) in parallel with Vocus proton transfer reaction mass spectrometry (PTR-MS), in line with sPTFE soil gas probes – successfully quantified isotopic signatures for N2O, CO2, and VOCs in real time as responses to changes in the dry–wetting cycle and redox conditions. Broadening the collection of trace gases that can be monitored in the subsurface is critical for monitoring biogeochemical cycles, ecosystem health, and management practices at scales relevant to the soil system.

54 ENVIRONMENTAL SCIENCES↗

Stimulated emission in multiple-photon-pumped xenon and argon excimers.

A pumping process involving the multiphoton absorption of laser radiation at 3547 and 2660 A is employed in the investigation. Typically, about 25% of the incident pumping radiation is absorbed and effective in producing excimer fluorescence. The four cases studied include 2660-A-pumped argon, 2660-A-pumped xenon, 3547-A-pumped xenon, and 3547-A-pumped argon. Results concerning the on-axis and off-axis fluorescence obtained from the excimers are presented in a graph.

Harris, S. E.↗

Signal averaging limitations in heterodyne- and direct-detection laser remote sensing measurements

The improvement in measurement uncertainty brought about by the averaging of increasing numbers of pulse return signals in both heterodyne- and direct-detection lidar systems is investigated. A theoretical analysis is presented which shows the standard deviation of the mean measurement to decrease as the inverse square root of the number of measurements, except in the presence of temporal correlation. Experimental measurements based on a dual-hybrid-TEA CO2 laser differential absorption lidar system are reported which demonstrate that the actual reduction in the standard deviation of the mean in both heterodyne- and direct-detection systems is much slower than the inverse square-root dependence predicted for uncorrelated signals, but is in agreement with predictions in the event of temporal correlation. Results thus favor the use of direct detection at relatively short range where the lower limit of the standard deviation of the mean is about 2 percent, but advantages of heterodyne detection at longer ranges are noted.

Menyuk, N.↗

An intercomparison of carbon monoxide measurement techniques

Results from an intercomparison of techniques to measure tropospheric levels of carbon monoxide (CO) are discussed. The intercomparison was conducted as part of the National Aeronautics and Space Administration's Global Tropospheric Experiment (GTE) and was held at Wallops Island, VA, in July 1983. Instruments intercompared included a laser differential absorption method and three grab sample/gas chromatograph methods. The intercomparison consisted of simultaneous measurements of ambient levels of CO and controlled injections of CO from a common manifold. Results from the techniques exhibited a high degree of correlation among themselves and with changes in the CO mixing ratio. The results suggested a level of agreement among the techniques of about 15 percent. However, a day-to-day bias between the techniques was observed, which resulted in differences between techniques as large as 38 percent.

Hoell, J. M., Jr.↗

Analysis of beamed-energy ramjet/scramjet performance

A study has been performed on a laser-heated ramjet/scramjet vehicle concept for propulsion during the air-breathing portion of an orbital launch trajectory. The concept considers axisymmetric, high-thrust vehicles with external inlets and nozzles. Conceptual design and ramjet/scramjet cycle analysis are emphasized, with propulsive energy provided by combustion of on-board fuel. The conventional ramjet/scramjet combustion chamber is replaced by a laser energy absorption chamber. The elimination of on-board propellant can result in very high thrust-to-weight ratios and payload fractions, in a vehicle with a relatively small degree of mechanical complexity. The basic vehicle has a weight of 12,250 lbf, and a diameter of 5 meters, which is close to the size of the Apollo command module. The ramjet calculations are based on a Mach 3 isentropic inlet with a 13.7 degree half-angle conical tip. The scramjet analysis considers conical inlets with 10, 15, and 30 degree half-angles. Flight Mach numbers from 2 to 20 are considered in the calculations.

Myrabo, L. N.↗