Search NASA⌕ Search

SEARCH · Search NASA

Results for “linearity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Catalytic converters having non-linear flow channels

Disclosed is a honeycomb catalyst substrate core having geometrically non-linear flow channels. In an embodiment, the honeycomb catalyst substrate core includes helical flow channels. In another embodiment, the honeycomb catalyst substrate core includes sinusoidal flow channels. In yet another embodiment, the honeycomb catalyst substrate core includes helical plus sinusoidal flow channels. The honeycomb catalyst substrate core comprises a plurality of parallel non-linear flow channels formed along a longitudinal axis of symmetry of the catalyst substrate core, each non-linear flow channel configured such that a turbulent vortical flow occurs during engine exhaust gas flow. Also disclosed is a method for manufacturing a ceramic honeycomb having non-linear flow channels, comprising the steps extrusion soft ceramic material through a die whilst the die moves through six degrees of freedom along its axis of symmetry. Disclosure includes a method for manufacturing a ceramic honeycomb having non-linear flow channels using three-dimensional printing.

33 ADVANCED PROPULSION SYSTEMS↗

Catalytic converters having non-linear flow channels

Disclosed is a honeycomb catalyst substrate core having geometrically non-linear flow channels. In an embodiment, the honeycomb catalyst substrate core includes helical flow channels. In another embodiment, the honeycomb catalyst substrate core includes sinusoidal flow channels. In yet another embodiment, the honeycomb catalyst substrate core includes helical plus sinusoidal flow channels. The honeycomb catalyst substrate core comprises a plurality of parallel non-linear flow channels formed along a longitudinal axis of symmetry of the catalyst substrate core, each non-linear flow channel configured such that eddies occurs during engine exhaust gas flow. Also disclosed is a method for manufacturing a ceramic honeycomb having non-linear flow channels, comprising the steps extrusion soft ceramic material through a die whilst the die moves through six degrees of freedom along its axis of symmetry. Disclosure includes a method for manufacturing a ceramic honeycomb having non-linear flow channels using three-dimensional printing.

Masoudi, Mansour↗

Toward Linear Stability Analysis of Upper Plenum Flows

Linear stability analysis is a tool used to help identify the sensitivity of a particular domain to perturbations and evaluate the system dynamics as a transition, if any, occurs. The development of a time invariant base flow for future use in a linear stability analysis is the focus of this investigation. A test case, with a Reynolds number of 100, was brought to a steady state using the spectral element code Nek5000 and the method of selective frequency damping. The convergence criteria for this method is the volume averaged value of the forcing function which, after approximately 80,000 time-steps, decreased to 3.6x10{sup -4}. Analysis shows that the case has yet to have reached the tolerance desired, 1x10{sup -6}. With the simulation in the process of converging a preliminary perturbation analysis was conducted. Due to the low Reynolds number of this case, 100, it was hypothesized that the flow would be linearly stable. This preliminary stability analysis only focused on the largest fundamental mode and the energy growth of that perturbation over time. Upon evaluation of the perturbation energy, which was shown to be monotonically decreasing in time, it was concluded that, despite not yet being converged, the system is in fact linearly stable. Future work includes evaluating the domain at higher Reynolds numbers, solving the eigenvalue problem created when the linearized Navier-Stokes are written in operator form and calculating the energy evolution of the optimal perturbation. (authors)

42 ENGINEERING↗

Application of linear prolongation to coarse mesh finite difference acceleration in CASMO5

The Coarse-Mesh Finite Difference (CMFD) method has been used for over a decade to accelerate the convergence of the Method of Characteristics (MOC) solution to the two- dimensional particle transport equation in CASMO5. Numerical testing, along with widespread use in production-level calculations, have shown that the current CMFD implementation provides stability and robustness for a wide range of realistic reactor physics problems. However, the recent development of linear prolongation has attracted attention from the community as a way to further improve the performance and stability of CMFD. Two interpolation methods for linear prolongation are presented in this work and implemented into a test version of CASMO5. The performance of the proposed interpolations, referred to as the bilinear and linear directional schemes, is evaluated in terms of runtime relative to the default constant or uniform scaling update. Numerical results indicate that the use of linear prolongation can reduce the transport solver runtime on average by approximately 10% when tested with two hundred randomly selected cases. The new directional linear interpolation, combined with default constant boundary updates, is found to provide the highest reduction in runtime for the cases analyzed. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Stochastic process models for linear structure behavior.

Linear systems are good approximations of the input-output relationship for many real systems. In practice, ensembles of nominally identical systems can seldom be adequately represented by a single linear system. Some accommodation needs to be made for representing inherent ensemble randomness. One approach would be to use a parameterized model of the system, with the random nature captured in discrete parameters of the parameterized model. Another approach is to use data measured from each system in the ensemble to represent the random nature of the ensemble in a non-parametric form. This is the approach described in this paper. There are several different types of data that could be collected from each system in the ensemble, each type capable of capturing the input-output behavior of the linear system: input-output time domain data, perhaps with specific excitation sequences; Markov parameters; and Frequency Response Functions (FRFs) to name a few. We choose to work with FRF data because many system attributes can be easily interpreted by inspection of the FRF. FRF data can also be used directly for control design. This paper develops a Karhunen-Loeve expansion representation for linear system behavior based on FRF data to develop a compact representation of the uncertainty inherent in an ensemble of systems. This non-parametric, compact, representation of the distribution of linear systems can then be used to characterize the performance and stability of a given feedback control law, as well as for control law design.

42 ENGINEERING↗

Solving large-scale sparse eigenvalue problems and linear systems of equations for accelerator modeling

The solutions of sparse eigenvalue problems and linear systems constitute one of the key computational kernels in the discretization of partial differential equations for the modeling of linear accelerators. The computational challenges faced by existing techniques for solving those sparse eigenvalue problems and linear systems call for continuing research to improve on the algorithms so that ever increasing problem size as required by the physics application can be tackled. Under the support of this award, the filter algorithm for solving large sparse eigenvalue problems was developed at Stanford to address the computational difficulties in the previous methods with the goal to enable accelerator simulations on then the world largest unclassified supercomputer at NERSC for this class of problems. Specifically, a new method, the Hemitian skew-Hemitian splitting method, was proposed and researched as an improved method for solving linear systems with non-Hermitian positive definite and semidefinite matrices.

43 PARTICLE ACCELERATORS↗

The Computer Program LIAR for Beam Dynamics Calculations in Linear Accelerators

Linear accelerators are the central components of the proposed next generation of linear colliders. They need to provide acceleration of up to 750 GeV per beam while maintaining very small normalized emittances. Standard simulation programs, mainly developed for storage rings, do not meet the specific requirements for high energy linear accelerators. We present a new program LIAR ('LInear Accelerator Research code') that includes wakefield effects, a 6D coupled beam description, specific optimization algorithms and other advanced features. Its modular structure allows to use and to extend it easily for different purposes. The program is available for UNIX workstations and Windows PC's. It can be applied to a broad range of accelerators. We present examples of simulations for SLC and NLC.

43 PARTICLE ACCELERATORS↗

Solving Large‐Scale Linear Systems of Equations by a Quantum Hybrid Algorithm

Abstract Today's intermediate‐scale quantum computers, although imperfect, already perform computational tasks that are manifestly beyond the capabilities of modern classical supercomputers. However, so far, quantum‐enabled large‐scale solutions have been realized only for limited set of problems. Here a hybrid algorithm based on phase estimation and classical optimization of the circuit width and depth is employed for solving a specific class of large linear systems of equations ubiquitous to many areas of science and engineering. A classification of linear systems based on the entanglement properties of the associated phase‐estimation unitary operation is introduced, enabling a highly efficient search for solutions that is facilitated by a straightforward matrix‐to‐circuit map. A 2 17 ‐dimensional problem is implemented on several IBM quantum computer superconducting quantum processors, a record‐breaking result for a linear system solved by a quantum computer. Demonstrated realisation sets a clear benchmark in the quest for the future quantum speedup in the linear systems of equations solution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum Algorithm for Linear Non-unitary Dynamics with Near-Optimal Dependence on All Parameters

We introduce a family of identities that express general linear non-unitary evolution operators as a linear combination of unitary evolution operators, each solving a Hamiltonian simulation problem. This formulation can exponentially enhance the accuracy of the recently introduced linear combination of Hamiltonian simulation (LCHS) method [An, Liu, and Lin, Physical Review Letters, 2023]. For the first time, this approach enables quantum algorithms to solve linear differential equations with both optimal state preparation cost and near-optimal scaling in matrix queries on all parameters.

Applied Dynamical Systems↗

Robust trajectory-constrained frequency control for microgrids considering model linearization error

Grid supportive modes integrated within inverter-based resources can improve the frequency response of renewable-rich microgrids. The synthesis of grid supportive modes to guarantee frequency trajectory constraints under a predefined disturbance set is challenging but essential. To tackle this challenge, a numerical optimal control (NOC)-based control synthesis methodology is proposed. Without loss of generality, a wind-diesel fed microgrid is studied, where we aim to design grid supportive functions in the wind turbine. In the control design, linearized models are used, and the linearization-induced errors are quantitatively analyzed by reachability and interval arithmetics and represented in the form of interval uncertainties. Then, the NOC problem can be formulated into a robust mixed-integer linear program. The control structure is strategically configured into two levels to realize online deployment. The proposed control is verified on the modified 33-node microgrid with a full-order three-phase nonlinear model in Simulink. In conclusion, the simulation results show the effectiveness of the proposed control paradigm and the necessity of considering linearization-induced uncertainty.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Linearization errors in discrete goal-oriented error estimation

This paper is concerned with goal-oriented a posteriori error estimation for nonlinear functionals in the context of nonlinear variational problems solved with continuous Galerkin finite element discretizations. A two-level, or discrete, adjoint-based approach for error estimation is considered. The traditional method to derive an error estimate in this context requires linearizing both the nonlinear variational form and the nonlinear functional of interest which introduces linearization errors into the error estimate. In this paper, we investigate these linearization errors. In particular, we develop a novel discrete goal-oriented error estimate that accounts for traditionally neglected nonlinear terms at the expense of greater computational cost. We demonstrate how this error estimate can be used to drive mesh adaptivity. Here, we show that accounting for linearization errors in the error estimate can improve its effectivity for several nonlinear model problems and quantities of interest. We also demonstrate that an adaptive strategy based on the newly proposed estimate can lead to more accurate approximations of the nonlinear functional with fewer degrees of freedom when compared to uniform refinement and traditional adjoint-based approaches.

42 ENGINEERING↗

Evaluation of Linear Accelerator Gating With Real-Time Electromagnetic Tracking

Purpose: Intrafraction organ motion can produce dosimetric errors in radiotherapy. Commonly, the linear accelerator is gated using real-time breathing phase obtained by way of external sensors. However, the external anatomy does not always correlate well with the internal position. We examined a beam gating technique using signals from implanted wireless transponders that provided real-time feedback on the tumor location without an imaging dose to the patient. Methods and Materials: An interface was developed between Calypso Medical's four-dimensional electromagnetic tracking system and a Varian Trilogy linear accelerator. A film phantom was mounted on a motion platform programmed with lung motion trajectories. Deliveries were performed when the beam was gated according to the signal from the wireless transponders. The dosimetric advantages of beam gating and the system latencies were quantified. Results: Beam gating using on internal position monitoring provided up to a twofold increase in the dose gradients. The percentage of points failing to be within {+-}10 cGy of the planned dose (maximal dose, {approx}200 cGy) was 3.4% for gating and 32.1% for no intervention in the presence of motion. The mean latencies between the transponder position and linear accelerator modulation were 75.0 {+-}12.7 ms for beam on and 65.1 {+-} 12.9 ms for beam off. Conclusion: We have presented the results from a novel method for gating the linear accelerator using trackable wireless internal fiducial markers without the use of ionizing radiation for imaging. The latencies observed were suitable for gating using electromagnetic fiducial markers, which results in dosimetric improvements for irradiation in the presence of motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Linear Accelerator-Based Intensity-Modulated Total Marrow Irradiation Technique for Treatment of Hematologic Malignancies: A Dosimetric Feasibility Study

Purpose: To investigate the dosimetric feasibility of linear accelerator-based intensity-modulated total marrow irradiation (IM-TMI) in patients with hematologic malignancies. Methods and Materials: Linear accelerator-based IM-TMI treatment planning was performed for 9 patients using the Eclipse treatment planning system. The planning target volume (PTV) consisted of all the bones in the body from the head to the mid-femur, except for the forearms and hands. Organs at risk (OAR) to be spared included the lungs, heart, liver, kidneys, brain, eyes, oral cavity, and bowel and were contoured by a physician on the axial computed tomography images. The three-isocenter technique previously developed by our group was used for treatment planning. We developed and used a common dose-volume objective method to reduce the planning time and planner subjectivity in the treatment planning process. Results: A 95% PTV coverage with the 99% of the prescribed dose of 12 Gy was achieved for all nine patients. The average dose reduction in OAR ranged from 19% for the lungs to 68% for the lenses. The common dose-volume objective method decreased the planning time by an average of 35% and reduced the inter- and intra- planner subjectivity. Conclusion: The results from the present study suggest that the linear accelerator-based IM-TMI technique is clinically feasible. We have demonstrated that linear accelerator-based IM-TMI plans with good PTV coverage and improved OAR sparing can be obtained within a clinically reasonable time using the common dose-volume objective method proposed in the present study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Approach to Failure Mode and Effect Analysis for Linear Accelerator Quality Assurance

Purpose: To determine clinic-specific linear accelerator quality assurance (QA) TG-142 test frequencies, to maximize physicist time efficiency and patient treatment quality. Methods and Materials: A novel quantitative approach to failure mode and effect analysis is proposed. Nine linear accelerator-years of QA records provided data on failure occurrence rates. The severity of test failure was modeled by introducing corresponding errors into head and neck intensity modulated radiation therapy treatment plans. The relative risk of daily linear accelerator QA was calculated as a function of frequency of test performance. Results: Although the failure severity was greatest for daily imaging QA (imaging vs treatment isocenter and imaging positioning/repositioning), the failure occurrence rate was greatest for output and laser testing. The composite ranking results suggest that performing output and lasers tests daily, imaging versus treatment isocenter and imaging positioning/repositioning tests weekly, and optical distance indicator and jaws versus light field tests biweekly would be acceptable for non-stereotactic radiosurgery/stereotactic body radiation therapy linear accelerators. Conclusions: Failure mode and effect analysis is a useful tool to determine the relative importance of QA tests from TG-142. Because there are practical time limitations on how many QA tests can be performed, this analysis highlights which tests are the most important and suggests the frequency of testing based on each test's risk priority number.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploiting ultra-large linear elasticity over a wide temperature range in nanocrystalline NiTi alloy

Many shape memory alloys can support large recoverable strains of a few percent by reversible stress-induced martensite transformation, yet they behave non-linear within a narrow operating temperature range. Developing the bulk metallic materials with ultra-large linear elasticity over a wide temperature range has proven to be difficult. In this work, a material design concept was proposed, that is true elastic deformation and reversible twinning-detwinning deformation run in parallel to overcome this challenge. By engineering the residual internal stress to realize the concurrency of true elastic deformation and twinning-detwinning deformation, a bulk nanocrystalline NiTi that possesses an ultra-large linear elastic strain up to 5.1 % and a high yield stress of 2.16 GPa over a wide temperature range of 270 °C was developed. This study offers a new avenue for developing the metallic materials with ultra-large linear elasticity over a wide temperature range of 270 °C (from 70 °C to -197 °C).

36 MATERIALS SCIENCE↗

Monitoring Linear Accelerator Output Constancy Using the PTW Linacheck

The PTW-Linacheck was assessed for its ability to monitor linear accelerator radiation output constancy. The key issues that were considered were the setup for daily output measurements, e.g., requirements for build-up and backscatter material, and the reproducibility and linearity of the device with linear accelerator output. An appropriate measurement setup includes a 10 x 10 cm field at 100 cm FSD, 5 cm backscatter, and no added build-up for 4 MeV electron beams, 1 cm added build-up for 6-16 MeV electron beams and 5 cm added build-up for 6-15 MV photon beams. Using this measurement setup, the dose linearity and short-term reproducibility were acceptable; however, the Linacheck should be recalibrated on a monthly basis to ensure acceptable long-term reproducibility.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ka-band linearizer for the Ultra-Compact X-ray free-electron laser at UCLA

There is a strong demand for accelerating structures able to achieve higher gradients and more compact dimensions for the next generation of linear accelerators for research, industrial and medical applications. Notably innovative technologies will permit compact and affordable advanced accelerators as the linear collider and X-ray free-electron lasers (XFELs) with accelerating gradients over twice the value achieved with current technologies. In particular XFELs are able to produce coherent X-ray pulses with peak brightness 10 orders of magnitude greater than preceding approaches, which has revolutionized numerous research fields through imaging of the nanoscopic world at the time and length scale of atom-based systems, that is of femtosecond and Angstrom. There is a strong interest for combining these two fields, to form a proper tool with the goal of producing a very compact XFEL in order to investigate multi-disciplinary topics in chemistry, biology, materials science, medicine and physics. In the framework of the Ultra-Compact XFEL project under study at the University of California, Los Angeles, a high gradient radio-frequency accelerating structure for the longitudinal phase-space linearization with an integrated voltage of at least 15 MV working on 6th harmonic of the main Linac frequency is required. We here present the electromagnetic design of a cryogenic normal-conducting 8 cm long Ka-band standing-wave linearizer working on π mode with a target accelerating gradient beyond 100 MV/m. The studies have been performed analytically and numerically to investigate the beam dynamics and electromagnetic issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray free electron laser linear accelerator without a laser heater

Linear accelerator based X-ray free electron laser (FEL) light sources provide an important tool for scientific discoveries. Most of these light source facilities employ a laser heater to increase the electron beam’s uncorrelated energy spread to suppress microbunching instability through the linear accelerators. In this paper, we first studied the microbunching instability in an X-ray FEL linear accelerator with lower initial peak current (~ 10 A) and moderate final peak currents (1-2 kA). In this regime, the microbunching instability can be substantially mitigated with modest initial uncorrelated energy spread. Here, we then suggested a less expensive method to mitigate the microbunching instability using a section of low beta FODO lattice instead of the laser heater. With the use of the high brightness electron beam from a photoinjector, the intrabeam scattering effect inside the beam through the FODO lattice can generate sufficient uncorrelated energy spread to mitigate the microbunching instability. At last, we demonstrated the feasibility of this method with self-consistent solution of the Fokker–Planck equation through the X-ray FEL linear accelerator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗