Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Structural investigation and applications of glassy sodium phosphate including the kinetics of dissolution rates and spectral analysis of the prepared samples with a focus on their effects on water treatment

This paper discuss the preparation of the binary system of Phosphate Based Glass (PBG) xP{sub 2}O{sub 5}–(100 − x) Na{sub 2}O mol% and investigates the compositions that form glassy matrix. It is found that x in the range between x = 40–60 mol% and divided in to 5 glass samples (x = 40, 45, 50, 55, 60) and for compositions of 40 > x > 60 no glassy matrix is formed. The intensities of the peak centers of the IR spectra of sodium phosphate glasses and the suggested vibrational modes of structural phosphate chains, terminal groups and tabulated data imply a shift in absorption bands with increasing the Na{sub 2}O mol% content. The amount of bridging phosphorous, shows a maximum value for the glass containing 60 mol% Na{sub 2}O due to the depolymerization of the phosphate matrix with increasing Na{sub 2}O content from 40 to 60 mol% via a breakdown of some terminal bonds (P=O) in the glass network which decreases the bond strength, consequently the peak center is shifted towards lower wave number. Essentially, five compositions of glassy samples were investigated: (x = 40, 45, 50, 55, and 60) mol%. The kinetics of dissolution rate were investigated by two ways: 1—the weight loss data and 2—electrical properties of the solution (pH, Electrical Conductivity) leached by the glass sample in to the deionized water. It is found that with increasing the Na{sub 2}O% content, the pH values, the dissolution rate and the solubility are increasing. It could be noticed that the ionic levels increased with the immersion time and were directly related to the solubility of the glasses. The highest in solubility (x = 40) is the highest in EC and pH values caused by high Na{sub 2}O%. By studying the effect of PBG on the real water medium physical characteristics the following results were achieved: Softening of (Treated drinking water, Nile raw water) by removal of hardness (Ca, Mg) by x = 50; 50% P{sub 2}O{sub 5}–50% Na{sub 2}O, Sequestering and agglomerating of (groundwater, wastewater) of some heavy metals as (Fe, Mn) up to 100% removal by x = 60; 60% P{sub 2}O{sub 5}–40% Na{sub 2}O and the electrical properties (pH, EC) were discussed. Results are assuring the possibility of applying PBG for groundwater treatment of high Fe and Mn content. The data show that municipal groundwater supplies become acceptable according to the guidelines of American Chemistry Council for safe drinking water by using of polyphosphates for water treatment.

54 ENVIRONMENTAL SCIENCES↗

Perturbative approach to covariance matrix of the matter power spectrum

Here, we evaluate the covariance matrix of the matter power spectrum using perturbation theory up to dominant terms at 1-loop order and compare it to numerical simulations. We decompose the covariance matrix into the disconnected (Gaussian) part, trispectrum from the modes outside the survey (beat coupling or super-sample variance), and trispectrum from the modes inside the survey, and show how the different components contribute to the overall covariance matrix. We find the agreement with the simulations is at a 10\% level up to $k \sim 1 h {\rm Mpc^{-1}}$. We also show that all the connected components are dominated by the large-scale modes ($k<0.1 h {\rm Mpc^{-1}}$), regardless of the value of the wavevectors $k,\, k'$ of the covariance matrix, suggesting that one must be careful in applying the jackknife or bootstrap methods to the covariance matrix. We perform an eigenmode decomposition of the connected part of the covariance matrix, showing that at higher $k$ it is dominated by a single eigenmode. Furthermore, the full covariance matrix can be approximated as the disconnected part only, with the connected part being treated as an external nuisance parameter with a known scale dependence, and a known prior on its variance for a given survey volume. Finally, we provide a prescription for how to evaluate the covariance matrix from small box simulations without the need to simulate large volumes.

79 ASTRONOMY AND ASTROPHYSICS↗

As-cast microstructures in U-Pu-Zr alloy fuel pins with 5-8 wt.% minor actinides and 0-1.5 wt% rare-earth elements

The Idaho National Laboratory (INL) is investigating U-Pu-Zr alloys with low concentrations of minor actinides (Np and Am) and rare-earth elements (La, Ce, Pr, and Nd) as possible nuclear fuels to be used to transmute minor actinides. Alloys with compositions 60U-20Pu-3Am-2Np-15Zr, 42U-30Pu-5Am-3Np-20Zr, 59U-20Pu-3Am-2Np-1RE-15Zr, 58.5U-20Pu-3Am-2Np-1.5RE-15Zr, 41U-30Pu-5Am-3Np-1RE-20Zr, and 40.5U-30Pu-5Am-3Np-1.5RE-20Zr (where numbers represent weight percents of each element and RE is a rare-earth alloy consisting of 6% La, 16% Pr, 25% Ce, and 53% Nd by weight) were arc-melted and vacuum cast as fuel pins approximately 4 mm in diameter. The as-cast pins were sectioned, polished, and examined by scanning electron microscopy. Each alloy contains high-Zr inclusions surrounded by a high-actinide matrix. Alloys with rare-earth elements also contain inclusions that are high in these elements. Within the matrix, concentrations of U and Zr vary inversely, while concentrations of Np and Pu appear approximately constant. Am occurs in the matrix and with some high-rare-earth inclusions, and occasionally as high-Am inclusions in samples without rare-earth elements. - Research Highlights: {yields}Microstructures consist of high-Zr inclusions surrounded by a high-actinide matrix. {yields}Alloys with rare-earth (RE) elements contain inclusions that are high in REs. {yields}Concentrations of U and Zr vary inversely in the matrix. {yields}Am occurs in the matrix and with high-RE inclusions.

36 MATERIALS SCIENCE↗

Microstructure characterization of as-fabricated and 475 Degrees C annealed U–7 wt.% Mo dispersion fuel in Al–Si alloy matrix

High-density uranium (U) alloys with an increased concentration of U are being examined for the development of research and test reactors with low enriched metallic fuels. The U-Mo fuel alloy dispersed in Al-Si alloy has attracted particular interest for this application. This paper reports our detailed characterization results of as-fabricated and annealed (475 Degrees C for 4 h) U-Mo dispersion fuels in Al-Si matrix with a Si concentration of 2 and 5 wt.%, named as As2Si, As5Si, An2Si, An5Si accordingly. Techniques employed for the characterization include scanning electron microscopy and transmission electron microscopy with specimen prepared by focused ion beam in situ lift-out. Fuel plates with Al-5 wt.% Si matrix consistently yielded thicker interaction layers developed between U-Mo particles and Al-Si matrix, than those with Al-2 wt.% Si matrix, given the same processing parameters. A single layer of interaction zone was observed in as-fabricated samples (i.e., As2Si, As5Si), and this layer mainly consisted of U3Si3Al2 phase. The annealed samples contained a two-layered interaction zone, with a Si-rich layer near the U-Mo side, and an Al-rich layer near the Al-Si matrix side. The U3Si5 appeared as the main phase in the Si-rich layer in An2Si sample, while both U3Si5 and U3Si3Al2 were identified in sample An5Si. The Al-rich layer in sample An2Si was amorphous, whereas that in sample An5Si mostly consisted of crystalline U(Al,Si)3, along with a small fraction of U(Al,Si)4 and U6Mo4Al43 phases. The influence of Si on the diffusion and reaction in the development of interaction layers in U(Mo)/Al(Si) is discussed in the light of growth-controlling mechanisms and irradiation performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

THE RESULTS OF TESTING TO EVALUATE CRYSTAL FORMATION AND SETTLING IN THE COLD CRUCIBLE INDUCTION MELTER

The Cold Crucible Induction Melter (CCIM) technology offers the potential to increase waste loading for High Level Waste (HLW) glasses leading to significant improvements in waste throughput rates compared to the reference Joule Heated Melter (JHM). Prior to implementation of a CCIM in a production facility it is necessary to better understand processing constraints associated with the CCIM. The glass liquidus temperature requirement for processing in the CCIM is an open issue. Testing was conducted to evaluate crystal formation and crystal settling during processing in the CCIM to gain insight into the effects on processing. A high aluminum/high iron content glass composition with known crystal formation tendencies was selected for testing. A continuous melter test was conducted for approximately 51 hours. To evaluate crystal formation, glass samples were obtained from pours and from glass receipt canisters where the glass melt had varying residence time in the melter. Additionally, upon conclusion of the testing, glass samples from the bottom of the melter were obtained to assess the degree of crystal settling. Glass samples were characterized in an attempt to determine quantitative fractions of crystals in the glass matrix. Crystal identity and relative composition were determined using a combination of x-ray diffraction (XRD) and scanning electron microscopy coupled with energy dispersive spectroscopy (SEM/EDS). Select samples were also analyzed by digesting the glass and determining the composition using inductively coupled atomic emission spectroscopy (ICP-AES). There was evidence of crystal formation (primarily spinels) in the melt and during cooling of the collected glass. There was evidence of crystal settling in the melt over the duration of the melter campaign.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nuclear radiation detectors based on a matrix of ion-implanted p-i-n diodes on undoped GaAs epilayers

Samples of nuclear detectors which represent matrices of p-i-n diodes were fabricated based on undoped gallium arsenide epitaxial layers by ion implantation technology. The detectors have a size of the active area of 0.4 Multiplication-Sign 0.4 and 0.9 Multiplication-Sign 0.9 cm{sup 2}. Electrical characteristics of fabricated detectors and results of measurements of fast neutrons spectra of {sup 241}Am-Be source by the recoil protons method are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Matrix diagonalization algorithm and its applicability to the nuclear shell model

An importance-sampling iterative algorithm for diagonalizing shell model Hamiltonian matrices is reviewed and implemented in a spin uncoupled basis. Shell model spaces of dimensions up to N < or approx.10{sup 9} are considered. The analysis shows that about 10% of the basis states are enough to bring the eigenvalues to convergence. This fraction of states, however, is insufficient to lead to convergence of the transition strengths, thereby limiting the applicability of the method to not too large spaces. In its domain of validity, the method yields a large number of eigensolutions and can be usefully adopted for rather complete studies of low-energy spectroscopy. This is done here for {sup 132,134}Xe isotopes. The calculation yields spectra and electromagnetic responses in fairly good agreement with the available experimental data and unveils the properties of the low-energy states of these isotopes, including their proton-neutron symmetry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of an Irradiated RERTR-7 Fuel Plate Using Transmission Electron Microscopy

Transmission electron microscopy (TEM) has been used to characterize an irradiated fuel plate with Al-2Si matrix from the RERTR-7 experiment that was irradiated under moderate reactor conditions. The results of this work showed the presence of a bubble superlattice within the U-7Mo grains that accommodated fission gases (e.g., Xe). The presence of this structure helps the U-7Mo exhibit a stable swelling behaviour during irradiation. Furthermore, TEM analysis showed that the Si-rich interaction layers that develop around the fuel particles at the U-7Mo/matrix interface during fuel plate fabrication and irradiation become amorphous during irradiation, and in regions of the interaction layer that have relatively high Si concentrations the fission gas bubbles remain small and contained within the layer but in areas with lower Si concentrations the bubbles grow in size. An important question that remains to be answered about the irradiation behaviour of U-Mo dispersion fuels, is how do more aggressive irradiation conditions affect the behaviour of fission gases within the U-7Mo fuel particles and in the amorphous interaction layers on the microstructural scale that can be characterized using TEM? This paper discusses the results of TEM analysis that was performed on a sample taken from an irradiated RERTR-7 fuel plate with Al-2Si matrix. This plate was exposed to more aggressive irradiation conditions than was the sample taken from the RERTR-6 plate. The microstructural features present within the U-7Mo and the amorphous interaction layers will be discussed. The results of this analysis will be compared to what was observed in the earlier RERTR-6 fuel plate characterization.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Accelerating actinium-225 purification by high-pressure ion chromatography

Actinium-225 (t1/2 = 9.92 days) is an important radioisotope for targeted alpha therapy applications. The limited supply obtained through the decay of thorium-229 has motivated accelerator-based production routes, including irradiation of thorium targets. Irradiated targets can produce useful quantities of actinium-225, but the product requires final purification from chemically similar lanthanide contaminants. This work describes an automated high-pressure ion chromatography method for this final polishing step. The method uses a reusable strong-acid cation-exchange column bearing sulfonic acid functional groups. α-Hydroxyisobutyric acid (α-HIBA), adjusted to pH 4.3 with lithium hydroxide, complexes and elutes lanthanides, a dilute hydrochloric acid matrix-exchange step removes residual α-HIBA, and concentrated hydrochloric acid then elutes retained actinium(III). The protocol purified actinium-225 to >99% radiopurity across tracer-level samples and samples containing >150 µCi (5.6 MBq) of activity. A 10 min, 0.1 M hydrochloric acid matrix exchange substantially reduced organic eluent carryover, and in-line sodium iodide detection enabled real-time monitoring of actinium and lanthanide elution. The developed method can be completed in <1 h and provides a basis for automated purification workflows for accelerator-produced actinium-225.

Gaddis, Kevin [ORNL] (ORCID:0000000183398314)↗

Galaxy–galaxy lensing estimators and their covariance properties

Here, we study the covariance properties of real space correlation function estimators – primarily galaxy–shear correlations, or galaxy–galaxy lensing – using SDSS data for both shear catalogues and lenses (specifically the BOSS LOWZ sample). Using mock catalogues of lenses and sources, we disentangle the various contributions to the covariance matrix and compare them with a simple analytical model. We show that not subtracting the lensing measurement around random points from the measurement around the lens sample is equivalent to performing the measurement using the lens density field instead of the lens overdensity field. While the measurement using the lens density field is unbiased (in the absence of systematics), its error is significantly larger due to an additional term in the covariance. Therefore, this subtraction should be performed regardless of its beneficial effects on systematics. Comparing the error estimates from data and mocks for estimators that involve the overdensity, we find that the errors are dominated by the shape noise and lens clustering, which empirically estimated covariances (jackknife and standard deviation across mocks) that are consistent with theoretical estimates, and that both the connected parts of the four-point function and the supersample covariance can be neglected for the current levels of noise. While the trade-off between different terms in the covariance depends on the survey configuration (area, source number density), the diagnostics that we use in this work should be useful for future works to test their empirically determined covariances.

79 ASTRONOMY AND ASTROPHYSICS↗

Structural, Optical, and Dielectric Studies on Sr-Doped Biferroic YCrO{sub 3}

In this work, the solid-state synthesis of Y{sub 1-x}Sr{sub x}CrO{sub 3} (x = 0.0, 0.1) samples has been reported. The X-ray diffraction data analysis confirmed that the synthesized samples have crystallized into the orthorhombic phase with the assigned space group Pbnm. The Rietveld refinement of the XRD data confirmed the structure and other related parameters. The slight variation in the lattice parameters and negligible shift in the reflection peaks reveals the uniform dispersion of Sr at Y-site in the parent YCrO{sub 3} matrix. The dielectric characterization revealed the good dielectric nature of the prepared samples which decreases with Sr doping. Field emission scanning electron microscopy (FE-SEM) revealed that an agglomeration type process has taken place in the sample preparation. Fourier transform infrared (FTIR) characterization witnessed the formation of orthorhombic phase of the samples under study displaying sharp absorption bands corresponding to Cr–O stretching, Y/Sr–O stretching, and O–Cr–O deformation vibration, respectively. UV-Vis spectroscopy analysis revealed the dual direct allowed bandgap of the samples assigned to the Cr{sup 3+} ion transition in the ground level.

36 MATERIALS SCIENCE↗

Wavelength dependence on the forensic analysis of glass by nanosecond 266 nm and 1064 nm laser induced breakdown spectroscopy

Laser induced breakdown spectroscopy can be used for the chemical characterization of glass to provide evidence of an association between a fragment found at a crime scene to a source of glass of known origin. Two different laser irradiances, 266 nm and 1064 nm, were used to conduct qualitative and quantitative analysis of glass standards. Single-pulse and double-pulse configurations and lens-to-sample-distance settings were optimized to yield the best laser-glass coupling. Laser energy and acquisition timing delays were also optimized to result in the highest signal-to-noise ratio corresponding to the highest precision and accuracy. The crater morphology was examined and the mass removed was calculated for both the 266 nm and 1064 nm irradiations. The analytical figures of merit suggest that the 266 nm and 1064 nm wavelengths are capable of good performance for the forensic chemical characterization of glass. The results presented here suggest that the 266 nm laser produces a better laser-glass matrix coupling, resulting in a better stoichiometric representation of the glass sample. The 266 nm irradiance is therefore recommended for the forensic analysis and comparison of glass samples.

74 ATOMIC AND MOLECULAR PHYSICS↗

Copper carbon composite wire with a uniform carbon dispersion made by friction extrusion

Copper-carbon composites are a group of materials with excellent mechanical, electrical, thermal, and tribological properties. However, bulk size copper-carbon composites made by the traditional manufacturing processes, like rolling or extrusion, fall short of reaching some of these properties predicted by theory or demonstrated only by samples at centimeter scale or smaller. The two main challenges to the successful scaling-up are: 1) to uniformly disperse carbon in the metal matrix; 2) to avoid degradation due to oxidation or reaction from overheating. In this work, we first demonstrate friction extrusion as a new method to make bulk-size void-free copper-carbon composite wires with homogenized carbon dispersion. Three different carbon varieties, graphite powder, graphene nanopowder, and carbon nanotubes, were added to the copper matrix with the concentration ranging from 0.5 wt% to 15 wt%. Special tooling, processing parameters, and procedures were developed, especially for high carbon content samples. Ten-fold reductions of both copper grain size and carbon particle size were achieved and attributed to the high shear deformation. Energy dispersive X-ray spectrometry indicates the carbon powder was refined to a sub-micron level and uniformly dispersed in the copper matrix. Compared with that of pure copper, the thermal capacity of the composite wire increases by 30 % while density reduces by 29 %.

Friction extrusion, Metal matrix composite, Graphe↗

Organic preservation of vase‐shaped microfossils from the late Tonian Chuar Group, Grand Canyon, Arizona, USA

Abstract Vase‐shaped microfossils (VSMs) are found globally in middle Neoproterozoic (800–730 Ma) marine strata and represent the earliest evidence for testate (shell‐forming) amoebozoans. VSM tests are hypothesized to have been originally organic in life but are most commonly preserved as secondary mineralized casts and molds. A few reports, however, suggest possible organic preservation. Here, we test the hypothesis that VSMs from shales of the lower Walcott Member of the Chuar Group, Grand Canyon, Arizona, contain original organic material, as reported by B. Bloeser in her pioneering studies of Chuar VSMs. We identified VSMs from two thin section samples of Walcott Member black shales in transmitted light microscopy and used scanning electron microscopy to image VSMs. Carbonaceous material is found within the internal cavity of all VSM tests from both samples and is interpreted as bitumen mobilized from Walcott shales likely during the Cretaceous. Energy dispersive X‐ray spectroscopy (EDS) and wavelength dispersive X‐ray spectroscopy (WDS) reveal that VSM test walls contain mostly carbon, iron, and sulfur, while silica is present only in the surrounding matrix. Raman spectroscopy was used to compare the thermal maturity of carbonaceous material within the samples and indicated the presence of pyrite and jarosite within fossil material. X‐ray absorption spectroscopy revealed the presence of reduced organic sulfur species within the carbonaceous test walls, the carbonaceous material found within test cavities, and in the sedimentary matrix, suggesting that organic matter sulfurization occurred within the Walcott shales. Our suite of spectroscopic analyses reveals that Walcott VSM test walls are organic and sometimes secondarily pyritized (with the pyrite variably oxidized to jarosite). Both preservation modes can occur at a millimeter spatial scale within sample material, and at times even within a single specimen. We propose that sulfurization within the Walcott Shales promoted organic preservation, and furthermore, the ratio of iron to labile VSM organic material controlled the extent of pyrite replacement. Based on our evidence, we conclude that the VSMs are preserved with original organic test material, and speculate that organic VSMs may often go unrecognized, given their light‐colored, translucent appearance in transmitted light.

58 GEOSCIENCES↗

Simultaneous Determination of Halogens and Metals in Waste Plastic Pyrolysis Oil by Inductively Coupled Plasma Mass Spectrometry

A major barrier to integrating pyrolysis-derived oil into conventional refinery technology is the presence of impurities, particularly halogens and metals, that can deactivate catalysts. This study presents a novel, cost-effective approach for the simultaneous analysis of a subset of halogens, metals, nonmetals, and metalloids in complex, industrially relevant distilled pyrolysis oil samples, this was previously achievable only through multiple techniques. Excellent results were obtained using a widely accessible inductively coupled plasma mass spectrometry (ICP-MS) method with helium gas mode and standard laboratory consumables, enabling high-throughput analysis and efficient evaluation of adsorbent performance. Sample preparation is straightforward, requiring only dilution in a compatible matrix, and provides accurate and precise quantification, with 75%–137% spike recovery for Be, Ti, V, Cr, Fe, Ni, Co, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, and 62%–65% spike recovery for Cl and 109%–133% spike recovery for Br. Additionally, an enhanced version of the method using ICP-MS/MS and hydrogen gas is described, which has higher accuracy with 69%–112% spike recovery for Be, B, Ti, V, Fe, Co, Ni, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, with 85%–102% spike recovery for Cl and 63%–93% spike recovery for Br. Helium mode detection limits for industrially relevant elements (V, Fe, Ni, Cu, As, and Pb) are less than 1.7 µg/kg, and less than 0.2 mg/kg for Br and Cl. Furthermore, this methodology facilitates rapid systematic evaluation of adsorption capacities of materials under time-on-stream conditions and supports robust comparisons across diverse operating environments.

Lazarcik, James [University of Wisconsin-Madison, ↗

Tribological Performance of Ni{sub 3}Al Matrix Composites Synthesized by Laser Melt Deposition Under Different Scanning Velocities

In order to study the effect of scanning velocity on the microstructure and tribological properties of Ni{sub 3}Al matrix composites containing graphene nanoplatelets (NGs), a series of NG samples are successfully synthesized by laser melt deposition under the various scanning velocities from 300 to 500 mm s{sup −1}. The sliding friction tests of NG against GCr15 steel balls are carried out under 10 N and 0.2 m s{sup −1} at room temperature. The microstructures, tribological properties and wear mechanisms of the NG samples are analyzed. The results show that the scanning velocity can be optimized to effectively control the surface hardness and relative density, as well as tribological performance of NG. The NG sample synthesized under scanning velocity of 450 mm s{sup −1} has a dense and fine microstructure as well as excellent properties such as higher relative density (98.6%), lower friction coefficient (0.23) and wear rate (5.5 × 10{sup −6} mm{sup 3} N{sup −1} m{sup −1}). The lower substrate layer with dense and stable structure plays an important role in supporting the upper glaze layer with rich graphene and oxides, as well as nanocrystalline structure, which contributes to the excellent friction-reducing and wear resistance performances of NG. The research results could be used to guide the selection of suitable scanning velocity and study the wear mechanisms of NG for having excellent tribological performance.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Determination of Resonance Parameters and their Covariances from Neutron Induced Reaction Cross Section Data

Cross section data in the resolved and unresolved resonance region are represented by nuclear reaction formalisms using parameters which are determined by fitting them to experimental data. Therefore, the quality of evaluated cross sections in the resonance region strongly depends on the experimental data used in the adjustment process and an assessment of the experimental covariance data is of primary importance in determining the accuracy of evaluated cross section data. In this contribution, uncertainty components of experimental observables resulting from total and reaction cross section experiments are quantified by identifying the metrological parameters involved in the measurement, data reduction and analysis process. In addition, different methods that can be applied to propagate the covariance of the experimental observables (i.e. transmission and reaction yields) to the covariance of the resonance parameters are discussed and compared. The methods being discussed are: conventional uncertainty propagation, Monte Carlo sampling and marginalization. It is demonstrated that the final covariance matrix of the resonance parameters not only strongly depends on the type of experimental observables used in the adjustment process, the experimental conditions and the characteristics of the resonance structure, but also on the method that is used to propagate the covariances. Finally, a special data reduction concept and format is presented, which offers the possibility to store the full covariance information of experimental data in the EXFOR library and provides the information required to perform a full covariance evaluation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗