Wind Prediction Accuracy for Air Traffic Management Decision Support Tools

The performance of Air Traffic Management and flight deck decision support tools depends in large part on the accuracy of the supporting 4D trajectory predictions. This is particularly relevant to conflict prediction and active advisories for the resolution of conflicts and the conformance with of traffic-flow management flow-rate constraints (e.g., arrival metering / required time of arrival). Flight test results have indicated that wind prediction errors may represent the largest source of trajectory prediction error. The tests also discovered relatively large errors (e.g., greater than 20 knots), existing in pockets of space and time critical to ATM DST performance (one or more sectors, greater than 20 minutes), are inadequately represented by the classic RMS aggregate prediction-accuracy studies of the past. To facilitate the identification and reduction of DST-critical wind-prediction errors, NASA has lead a collaborative research and development activity with MIT Lincoln Laboratories and the Forecast Systems Lab of the National Oceanographic and Atmospheric Administration (NOAA). This activity, begun in 1996, has focussed on the development of key metrics for ATM DST performance, assessment of wind-prediction skill for state of the art systems, and development/validation of system enhancements to improve skill. A 13 month study was conducted for the Denver Center airspace in 1997. Two complementary wind-prediction systems were analyzed and compared to the forecast performance of the then standard 60 km Rapid Update Cycle - version 1 (RUC-1). One system, developed by NOAA, was the prototype 40-km RUC-2 that became operational at NCEP in 1999. RUC-2 introduced a faster cycle (1 hr vs. 3 hr) and improved mesoscale physics. The second system, Augmented Winds (AW), is a prototype en route wind application developed by MITLL based on the Integrated Terminal Wind System (ITWS). AW is run at a local facility (Center) level, and updates RUC predictions based on an optimal interpolation of the latest ACARS reports since the RUC run. This paper presents an overview of the study's results including the identification and use of new large mor wind-prediction accuracy metrics that are key to ATM DST performance.

Cole, Rod↗

Optimal Design of Passive Flow Control for a Boundary-Layer-Ingesting Offset Inlet Using Design-of-Experiments

This research will investigate the use of Design-of-Experiments (DOE) in the development of an optimal passive flow control vane design for a boundary-layer-ingesting (BLI) offset inlet in transonic flow. This inlet flow control is designed to minimize the engine fan-face distortion levels and first five Fourier harmonic half amplitudes while maximizing the inlet pressure recovery. Numerical simulations of the BLI inlet are computed using the Reynolds-averaged Navier-Stokes (RANS) flow solver, OVERFLOW, developed at NASA. These simulations are used to generate the numerical experiments for the DOE response surface model. In this investigation, two DOE optimizations were performed using a D-Optimal Response Surface model. The first DOE optimization was performed using four design factors which were vane height and angles-of-attack for two groups of vanes. One group of vanes was placed at the bottom of the inlet and a second group symmetrically on the sides. The DOE design was performed for a BLI inlet with a free-stream Mach number of 0.85 and a Reynolds number of 2 million, based on the length of the fan-face diameter, matching an experimental wind tunnel BLI inlet test. The first DOE optimization required a fifth order model having 173 numerical simulation experiments and was able to reduce the DC60 baseline distortion from 64% down to 4.4%, while holding the pressure recovery constant. A second DOE optimization was performed holding the vanes heights at a constant value from the first DOE optimization with the two vane angles-of-attack as design factors. This DOE only required a second order model fit with 15 numerical simulation experiments and reduced DC60 to 3.5% with small decreases in the fourth and fifth harmonic amplitudes. The second optimal vane design was tested at the NASA Langley 0.3- Meter Transonic Cryogenic Tunnel in a BLI inlet experiment. The experimental results showed a 80% reduction of DPCP(sub avg), the circumferential distortion level at the engine fan-face.

Allan, Brian G.↗

20 Meter Solar Sail Analysis and Correlation

This presentation discusses studies conducted to determine the element type and size that best represents a 20-meter solar sail under ground-test load conditions, the performance of test/Analysis correlation by using Static Shape Optimization Method for Q4 sail, and system dynamic. TRIA3 elements better represent wrinkle patterns than do QUAD3 elements Baseline, ten-inch elements are small enough to accurately represent sail shape, and baseline TRIA3 mesh requires a reasonable computation time of 8 min. 21 sec. In the test/analysis correlation by using Static shape optimization method for Q4 sail, ten parameters were chosen and varied during optimization. 300 sail models were created with random parameters. A response surfaces for each targets which were created based on the varied parameters. Parameters were optimized based on response surface. Deflection shape comparison for 0 and 22.5 degrees yielded a 4.3% and 2.1% error respectively. For the system dynamic study testing was done on the booms without the sails attached. The nominal boom properties produced a good correlation to test data the frequencies were within 10%. Boom dominated analysis frequencies and modes compared well with the test results.

Taleghani, B.↗

Multiphase Flow Technology Impacts on Thermal Control Systems for Exploration

The Two-Phase Flow Facility (TPHIFFy) Project focused on bridging the critical knowledge gap by developing and demonstrating critical multiphase fluid products for advanced life support, thermal management and power conversion systems that are required to enable the Vision for Space Exploration. Safety and reliability of future systems will be enhanced by addressing critical microgravity fluid physics issues associated with flow boiling, condensation, phase separation, and system stability. The project included concept development, normal gravity testing, and reduced gravity aircraft flight campaigns, in preparation for the development of a space flight experiment implementation. Data will be utilized to develop predictive models that could be used for system design and operation. A single fluid, two-phase closed thermodynamic loop test bed was designed, assembled and tested. The major components in this test bed include: a boiler, a condenser, a phase separator and a circulating pump. The test loop was instrumented with flow meters, thermocouples, pressure transducers and both high speed and normal speed video cameras. A low boiling point surrogate fluid, FC-72, was selected based on scaling analyses using preliminary designs for operational systems. Preliminary results are presented which include flow regime transitions and some observations regarding system stability.

McQuillen, John↗

Optimal Design of Passive Flow Control for a Boundary-Layer-Ingesting Offset Inlet Using Design-of-Experiments

This research will investigate the use of Design-of-Experiments (DOE) in the development of an optimal passive flow control vane design for a boundary-layer-ingesting (BLI) offset inlet in transonic flow. This inlet flow control is designed to minimize the engine fan face distortion levels and first five Fourier harmonic half amplitudes while maximizing the inlet pressure recovery. Numerical simulations of the BLI inlet are computed using the Reynolds-averaged Navier-Stokes (RANS) flow solver, OVERFLOW, developed at NASA. These simulations are used to generate the numerical experiments for the DOE response surface model. In this investigation, two DOE optimizations were performed using a D-Optimal Response Surface model. The first DOE optimization was performed using four design factors which were vane height and angles-of-attack for two groups of vanes. One group of vanes was placed at the bottom of the inlet and a second group symmetrically on the sides. The DOE design was performed for a BLI inlet with a free-stream Mach number of 0.85 and a Reynolds number of 2 million, based on the length of the fan face diameter, matching an experimental wind tunnel BLI inlet test. The first DOE optimization required a fifth order model having 173 numerical simulation experiments and was able to reduce the DC60 baseline distortion from 64% down to 4.4%, while holding the pressure recovery constant. A second DOE optimization was performed holding the vanes heights at a constant value from the first DOE optimization with the two vane angles-of-attack as design factors. This DOE only required a second order model fit with 15 numerical simulation experiments and reduced DC60 to 3.5% with small decreases in the fourth and fifth harmonic amplitudes. The second optimal vane design was tested at the NASA Langley 0.3-Meter Transonic Cryogenic Tunnel in a BLI inlet experiment. The experimental results showed a 80% reduction of DPCPavg, the circumferential distortion level at the engine fan face.

Allan, Brian G.↗

Propeller-Design Problems of High-Speed Airplanes, Special Report

It is shown that on the basis of existing high-speed airfoil data, propeller efficiencies appreciably in excess of 40% do not appear possible at speeds above 500 miles per hour at 20,000 feet. The assumption that present propeller-blade thicknesses cannot be reduced radically, is implied. Until the reliability and applicability of the airfoil data are established, this conclusion must not be regarded as infallible. Dive tests with airplanes equipped with thrust meters and torque meters are proposed to provide an urgently needed check. The design of high-speed propellers is dictated wholly by compressibility considerations. The blade width, thickness, and pitch distribution; also the airfoil sections, the lift coefficient, the propeller diameter, and rpm must all be adjusted if reasonable efficiencies are to be maintained at airplane speeds that are now being approached. Research is urgently needed on: 1) airfoils at subsonic, sonic, and supersonic speeds; 2) propellers at high forward speeds in wind tunnels; 3)propellers in free flight at high speeds; and 4) jet propulsion and related devices. The breakdown of propeller efficiency indicated by airfoil data, should serve as an incentive for accelerated research on jet propulsion. This device may extend the attainable speed of current airplanes to the neighborhood of 550 miles per hour at 20,000 feet.

Dickinson, H. B.↗

Aerodynamic Models for the Low Density Supersonic Declerator (LDSD) Supersonic Flight Dynamics Test (SFDT)

An overview of pre-flight aerodynamic models for the Low Density Supersonic Decelerator (LDSD) Supersonic Flight Dynamics Test (SFDT) campaign is presented, with comparisons to reconstructed flight data and discussion of model updates. The SFDT campaign objective is to test Supersonic Inflatable Aerodynamic Decelerator (SIAD) and large supersonic parachute technologies at high altitude Earth conditions relevant to entry, descent, and landing (EDL) at Mars. Nominal SIAD test conditions are attained by lifting a test vehicle (TV) to 36 km altitude with a large helium balloon, then accelerating the TV to Mach 4 and and 53 km altitude with a solid rocket motor. The first flight test (SFDT-1) delivered a 6 meter diameter robotic mission class decelerator (SIAD-R) to several seconds of flight on June 28, 2014, and was successful in demonstrating the SFDT flight system concept and SIAD-R. The trajectory was off-nominal, however, lofting to over 8 km higher than predicted in flight simulations. Comparisons between reconstructed flight data and aerodynamic models show that SIAD-R aerodynamic performance was in good agreement with pre-flight predictions. Similar comparisons of powered ascent phase aerodynamics show that the pre-flight model overpredicted TV pitch stability, leading to underprediction of trajectory peak altitude. Comparisons between pre-flight aerodynamic models and reconstructed flight data are shown, and changes to aerodynamic models using improved fidelity and knowledge gained from SFDT-1 are discussed.

Van Norman, John W.↗

High-Frequency Density Oscillations from a Plasma Source Used for Simulating Low-Earth Orbit Plasma Environment

We present data from ground-based, vacuum-chamber tests demonstrating the ability to modulate the output of a plasma source capable of producing a low-Earth orbit (LEO) type plasma. We obtained plasma oscillations up to 2.5 kHz impingent on stationary test equipment, which corresponds to meter-level ionospheric structures in LEO. This plasma source is, therefore, suitable for developing scientific instruments that measure the LEO plasma environment, in situ, with meter-level spatial resolution. Measurements were made using a fixed-bias collector and an electrometer sampling at 40 kHz. A mechanical aperture was established at the output of the plasma source via two concentric grids. The outer grid was free to rotate in the azimuthal direction with respect to the fixed inner grid. An identical, alternating hole pattern in the two grids resulted in a variable aperture that cycles through 90 open/close cycles per revolution. The frequency of the plasma oscillations is limited by the mechanism used to spin the grids and the bearing assembly on which the grids rotate. Higher frequencies are obtainable by upgrading the drive mechanism, allowing the possibility of centimeter-level spatial resolution.

McTernan, Jesse K.↗

Front Range Wildland Fires: Evaluating the Efficacy of Remote Sensing Imagery in Monitoring Forest Fuels Treatment Methods

Over the last several decades, wildfire frequency and severity in forested areas along Colorado’s Front Range have increased due to a buildup of fuels. This has led to an increase in forest treatments, as well as an increased need to evaluate the success of these treatments. Remote sensing products offer an efficient and cost-effective way to monitor forest treatments; however, not all remote sensing products and analysis techniques have been explored by Coloradan land managers. Specifically, project partners at the Colorado State Forest Service (CSFS) and the Colorado Forest Restoration Institute (CFRI) were interested in using an effective and streamlined method of mapping canopy cover to better monitor forest treatment success. To support their needs, the NASA DEVELOP Front Range Wildland Fires team explored National Agricultural Imagery Program (NAIP) imagery at different spatial resolutions and numbers of training points with NASA’s Shuttle Radar Topography Mission (SRTM) Data Elevation Model (DEM) as a predictor in addition to NAIP imagery spectral predictors. From this analysis, we created classified canopy cover rasters, and compared accuracy metrics across model iterations. We also determined that the best performing model, with an overall accuracy of 0.900 uses 2021 NAIP imagery at 2-meter resolution, 800 training points, 200 testing points, does not use topographic predictors, and reclassifies shadow pixels via a pre-selected NDVI threshold.

Remote Sensing↗

Validation and Development of a Fast-Running CFD Model for the No-Vent Fill of Liquid Propellant Tank

Cryogenic fluids, while offering higher energy density than storable propellants, present several handling challenges, including gradual boil-off and tank self-pressurization. Transferring these propellants between tanks can be problematic, as the receiving tank's temperature and pressure often lead to flashing and rapid boil-off upon injection. The No-Vent Fill (NVF) technique mitigates these risks by preventing liquid fuel from being expelled overboard. By controlling tank pressure and ensuring appropriate condensation in the ullage region, the NVF process avoids exceeding vent pressure limits. In this study, Loci/STREAM-VOF simulations were compared with data from NASA K-site test runs on a 2.1 cubic meter tank with a bottom orifice under various no-vent fill conditions, including different wall temperatures, flow rates, and inlet liquid temperatures. The effort demonstrated that Loci/STREAM-VOF is capable of quantitatively capturing the important physics of NVF with submerged jets: (1) validation of the liquid-vapor interface turbulence velocity using previous experimental data showed good agreement at different fill levels; (2) validation of the CFD Stanton number for mass transfer provided an adequate mass transfer coefficient range; (3) consistent pressure agreements were found in the pressure history for both cold and warm conditions; and (4) the variations of final pressure with flow rate and inlet liquid temperature were well predicted by the CFD simulation. The application of NVF for low-gravity conditions will be studied in future work.

CFD↗

Validation and Development of a Fast-Running CFD Model for the No-Vent Fill of Liquid Propellant Tank

Cryogenic fluids, while offering higher energy density than storable propellants, present several handling challenges, including gradual boil-off and tank self-pressurization. Transferring these propellants between tanks can be problematic, as the receiving tank's temperature and pressure often lead to flashing and rapid boil-off upon injection. The No-Vent Fill (NVF) technique mitigates these risks by preventing liquid fuel from being expelled overboard. By controlling tank pressure and ensuring appropriate condensation in the ullage region, the NVF process avoids exceeding vent pressure limits. In this study, Loci/STREAM-VOF simulations were compared with data from NASA K-site test runs on a 2.1 cubic meter tank with a bottom orifice under various no-vent fill conditions, including different wall temperatures, flow rates, and inlet liquid temperatures. The effort demonstrated that Loci/STREAM-VOF is capable of quantitatively capturing the important physics of NVF with submerged jets: (1) validation of the liquid-vapor interface turbulence velocity using previous experimental data showed good agreement at different fill levels; (2) validation of the CFD Stanton number for mass transfer provided an adequate mass transfer coefficient range; (3) consistent pressure agreements were found in the pressure history for both cold and warm conditions; and (4) the variations of final pressure with flow rate and inlet liquid temperature were well predicted by the CFD simulation. The application of NVF for low-gravity conditions will be studied in future work.

CFD↗

Examination of a Standardized Test for Evaluating the Degree of Cure of EVA Encapsulation: Preprint

The curing of cross-linkable encapsulation is a critical consideration for photovoltaic (PV) modules manufactured using a lamination process. Concerns related to ethylene-co-vinyl acetate (EVA) include the quality (e.g., expiration and uniformity) of the films or completion (duration) of the cross-linking of the EVA within a laminator. Because these issues are important to both EVA and module manufacturers, an international standard has recently been proposed by the Encapsulation Task-Group within the Working Group 2 (WG2) of the International Electrotechnical Commission (IEC) Technical Committee 82 (TC82) for the quantification of the degree of cure for EVA encapsulation. The present draft of the standard calls for the use of differential scanning calorimetry (DSC) as the rapid, enabling secondary (test) method. Both the residual enthalpy- and melt/freeze-DSC methods are identified. The DSC methods are calibrated against the gel content test, the primary (reference) method. Aspects of other established methods, including indentation and rotor cure metering, were considered by the group. Key details of the test procedure will be described.

14 SOLAR ENERGY↗

Examination of a Standardized Test for Evaluating the Degree of Cure of EVA Encapsulation (Presentation)

The curing of cross-linkable encapsulation is a critical consideration for photovoltaic (PV) modules manufactured using a lamination process. Concerns related to ethylene-co-vinyl acetate (EVA) include the quality (e.g., expiration and uniformity) of the films or completion (duration) of the cross-linking of the EVA within a laminator. Because these issues are important to both EVA and module manufacturers, an international standard has recently been proposed by the Encapsulation Task-Group within the Working Group 2 (WG2) of the International Electrotechnical Commission (IEC) Technical Committee 82 (TC82) for the quantification of the degree of cure for EVA encapsulation. The present draft of the standard calls for the use of differential scanning calorimetry (DSC) as the rapid, enabling secondary (test) method. Both the residual enthalpy- and melt/freeze-DSC methods are identified. The DSC methods are calibrated against the gel content test, the primary (reference) method. Aspects of other established methods, including indentation and rotor cure metering, were considered by the group. Key details of the test procedure will be described.

14 SOLAR ENERGY↗

Toward large-scale building detection with convolutional neural network using remote sensing images

Establishing up-to-date nationwide building maps is essential to understand urban dynamics, such as estimating population and urban planning and many other applications. However, an efficient and effective solution is yet to be developed. In this paper, for the first time we evaluate three state-of-the-art CNNs for detecting buildings across entire United States using aerial images. The three CNN architectures, fully convolutional neural network, conditional random field as recurrent neural network, and SegNet, support semantic pixel-wise labeling and focus on capturing textural information at multi-scale. We use 1-meter resolution NAIP images as the test data set, and compare the detection results across the three methods. In addition, we propose to combine signed distance function labels with SegNet, which is the preferred CNN architecture identified by our extensive evaluations. The results are further improved in terms of precision, recall rate and the number of building detected. On average, model inference on test images is less than one minute for an area of size $\sim56$ $km^2$. With these promising results and the time required to process images, the framework offers great potential toward country scale building mapping with remote sensing imagery.

Yang, Lexie↗

Solar-Powered Air Stripping at the Rocky Flats Site, Colorado - 12361

The U.S. Department of Energy's Rocky Flats Site (the Site), near Denver, Colorado, is a former nuclear weapons facility that was constructed beginning in 1951. With the end of the Cold War, the Site was cleaned up and closed in 2005. Four gravity-driven groundwater treatment systems were installed during cleanup, and their continued operation was incorporated into the final remedy for the Site. All utilities, including electrical power, were removed as part of this closure, so all Site electrical power needs are now met with small solar-powered systems. The Mound Site Plume Treatment System (MSPTS) was installed in 1998 as an innovative system based on zero-valent iron (ZVI). Groundwater flow from the Mound source area containing elevated concentrations of volatile organic compounds (VOCs), primarily in the tetrachloroethene (PCE)-trichloroethene (TCE) family of chlorinated solvents, is intercepted by a collection trench and routed to twin ZVI treatment cells. Later, in 2005, remediation of VOC-contaminated soils at a second up-gradient source area included adding an electron donor to the backfill to help stimulate biodegradation. This reduced concentrations of primary constituents but caused down-gradient groundwater to contain elevated levels of recalcitrant degradation byproducts, particularly cis-1,2-dichloroethene and vinyl chloride. A gravel drain installed as part of the 2005 remediation directs contaminated groundwater from this second source area to the MSPTS for treatment. This additional contaminant load, coupled with correspondingly reduced residence time within the ZVI media due to the increased flow rate, resulted in reduced treatment effectiveness. Elevated concentrations of VOCs were then detected in MSPTS effluent, as well as in surface water at the downstream performance monitoring location for the MSPTS. Subsequent consultations with the Site regulators led to the decision to add a polishing component to reduce residual VOCs in MSPTS effluent. Initially, several alternatives such as commercial air strippers and cascade aerators were evaluated; resulting cost estimates exceeded $100,000. After several simpler alternatives were considered and prototype testing was conducted, the existing effluent metering manhole was converted to house a spray-nozzle based, solar-powered air stripper, at a cost of approximately $20,000. About two-thirds of this cost was for the solar power system, which was initially designed to only provide power for 12 hours per day. Performance data are being collected and adjustments made to optimize the design, determine maintenance requirements, and establish power needs for continuous operation. Analytical data confirm the air stripper is sharply reducing concentrations of residual contaminants. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2013 Caliban and Prospero experiments for the study of the behavior of radiation protection instrumentations in case of a criticality accident - 14346

Experiments using the CALIBAN and PROSPERO reactors were performed in 2013 in the framework of a collaboration between IRSN and CEA. The objective was to provide data about the possibility to use information given by radiation protection instrumentations (RPI) in the case of a criticality accident. In that purpose, the behavior of RPI was studied for various kinetics of the reactors which simulated different starts of a criticality accident. The article presents the safety issues associated with these experiments, i.e. the possible use of information given by the RPI for the emergency response of a criticality accident (detection of the accident, triage of the personnel, follow-up of the accident and reentry). Then, one paragraph is dedicated to the presentation of the tested material. In addition, the CALIBAN and PROSPERO reactors are briefly described, followed by the performed experiments. The RPI are neither designed nor dedicated to be used in case of a criticality accident. However, the preliminary conclusion of the experiments performed in 2013 is that the tested RPI have a correct behavior for slow kinetic experiments performed with the PROSPERO reactor, but might give less reliable and accurate information for pulse experiments performed with the CALIBAN reactor. In the last case, they can nevertheless provide information that can be helpful for the emergency response and the limitation of the consequences of the criticality accident. However, if the RPI are included in the emergency response of a criticality accident (detection, triage, follow-up, reentry), emergency procedures should be adapted. Other experiments might be performed in order to confirm results and to extend the number of tested materials, in particular portable survey meters or contamination area monitors. (authors)

42 ENGINEERING↗

Ground-based time-guidance algorithm for control of airplanes in a time-metered air traffic control environment: A piloted simulation study

The rapidly increasing costs of flight operations and the requirement for increased fuel conservation have made it necessary to develop more efficient ways to operate airplanes and to control air traffic for arrivals and departures to the terminal area. One concept of controlling arrival traffic through time metering has been jointly studied and evaluated by NASA and ONERA/CERT in piloted simulation tests. From time errors attained at checkpoints, airspeed and heading commands issued by air traffic control were computed by a time-guidance algorithm for the pilot to follow that would cause the airplane to cross a metering fix at a preassigned time. These tests resulted in the simulated airplane crossing a metering fix with a mean time error of 1.0 sec and a standard deviation of 16.7 sec when the time-metering algorithm was used. With mismodeled winds representing the unknown in wind-aloft forecasts and modeling form, the mean time error attained when crossing the metering fix was increased and the standard deviation remained approximately the same. The subject pilots reported that the airspeed and heading commands computed in the guidance concept were easy to follow and did not increase their work load above normal levels.

Knox, C. E.↗

Development of the 15-meter hoop-column antenna system

The development of the 15-meter hoop/column antenna system is presented. The 15-meter deployable structure is discussed along with the mulitple-beam feed system development and the structures and RF testing planned in 1985. The topics presented are: overview of antenna development activities; development of 15-meter reflector and kinematic deployment tests; preliminary modal survey test results and future structural dynamics tests; and radio frequency subsystems and near field testing.

Campbell, T. G.↗