Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

A Radar/Radiometer Instrument for Mapping Soil Moisture and Ocean Salinity

The RadSTAR instrument combines an L-band, digital beam-forming radar with an L-band synthetic aperture, thinned array (STAR) radiometer. The RadSTAR development will support NASA Earth science goals by developing a novel, L-band scatterometer/ radiometer that measures Earth surface bulk material properties (surface emissions and backscatter) as well as surface characteristics (backscatter). Present, real aperture airborne L-Band active/passive measurement systems such as the JPUPALS (Wilson, et al, 2000) provide excellent sampling characteristics, but have no scanning capabilities, and are extremely large; the huge JPUPALS horn requires a the C-130 airborne platform, operated with the aft loading door open during flight operation. The approach used for the upcoming Aquarius ocean salinity mission or the proposed Hydros soil mission use real apertures with multiple fixed beams or scanning beams. For real aperture instruments, there is no upgrade path to scanning over a broad swath, except rotation of the whole aperture, which is an approach with obvious difficulties as aperture size increases. RadSTAR will provide polarimetric scatterometer and radiometer measurements over a wide swath, in a highly space-efficient configuration. The electronic scanning approaches provided through STAR technology and digital beam forming will enable the large L-band aperture to scan efficiently over a very wide swath. RadSTAR technology development, which merges an interferometric radiometer with a digital beam forming scatterometer, is an important step in the path to space for an L-band scatterometer/radiometer. RadSTAR couples a patch array antenna with a 1.26 GHz digital beam forming radar scatterometer and a 1.4 GHz STAR radiometer to provide Earth surface backscatter and emission measurements in a compact, cross-track scanning instrument with no moving parts. This technology will provide the first L-band, emission and backscatter measurements in a compact aircraft instrument and will be ideally suited to large apertures, possibly at GEO, and could possibly be implemented on a swarm of micro-satellites. This instrument will have wide application for validation studies, and will have application for other microwave frequencies.

Hildebrand, Peter H.↗

High-Efficiency Inductive Output Tubes Using a Third Harmonic Drive on the Grid

In this article, we discuss the use of a third harmonic component to the drive voltage on the grid of an inductive output tube (IOT). High-efficiency IOTs are typically characterized by efficiencies up to 70%–75%. However, the achievement of efficiencies greater than 80% would substantially reduce the operating costs of next-generation accelerators. In order to achieve this goal, we consider the addition of a third harmonic component to the drive signal on the grid of an IOT. The use of a third harmonic drive component in IOT guns has been considered in order to apply such a gun as the injector of radio frequency linear accelerators (RF linacs). Furthermore, we consider that the IOT will be used to provide the rf power to drive RF linacs and apply the third harmonic with the intention of increasing the efficiency of the RF output of the IOT. We consider a model IOT with a 700-MHz resonant cavity and using an annular beam with a voltage of 30 kV, an average current of 6.67 A yielding a perveance of about 1.3 μP. We simulate this IOT using the NEMESIS simulation code which has been successfully validated by comparison with the K5H90W-2 IOT developed by Communications and Power Industries. It is found that the effect of the third harmonic on the efficiency is greatest when the phase of the third harmonic is shifted by radians with respect to the fundamental drive signal and with third harmonic powers greater than about 50% that of the fundamental drive power. For the present example, we show that efficiencies approaching 86% are possible by this means.

43 PARTICLE ACCELERATORS↗

Application of spherical diodes for megavoltage photon beams dosimetry

Purpose: External beam radiation therapy (EBRT) usually uses heterogeneous dose distributions in a given volume. Designing detectors for quality control of these treatments is still a developing subject. The size of the detectors should be small to enhance spatial resolution and ensure low perturbation of the beam. A high uniformity in angular response is also a very important feature in a detector, because it has to measure radiation coming from all the directions of the space. It is also convenient that detectors are inexpensive and robust, especially to performin vivo measurements. The purpose of this work is to introduce a new detector for measuring megavoltage photon beams and to assess its performance to measure relative dose in EBRT. Methods: The detector studied in this work was designed as a spherical photodiode (1.8 mm in diameter). The change in response of the spherical diodes is measured regarding the angle of incidence, cumulated irradiation, and instantaneous dose rate (or dose per pulse). Additionally, total scatter factors for large and small fields (between 1 × 1 cm{sup 2} and 20 × 20 cm{sup 2}) are evaluated and compared with the results obtained from some commercially available ionization chambers and planar diodes. Additionally, the over-response to low energy scattered photons in large fields is investigated using a shielding layer. Results: The spherical diode studied in this work produces a high signal (150 nC/Gy for photons of nominal energy of 15 MV and 160 for 6 MV, after 12 kGy) and its angular dependence is lower than that of planar diodes: less than 5% between maximum and minimum in all directions, and 2% around one of the axis. It also has a moderated variation with accumulated dose (about 1.5%/kGy for 15 MV photons and 0.7%/kGy for 6 MV, after 12 kGy) and a low variation with dose per pulse (±0.4%), and its behavior is similar to commercial diodes in total scatter factor measurements. Conclusions: The measurements of relative dose using the spherical diode described in this work show its feasibility for the dosimetry of megavoltage photon beams. A particularly important feature is its good angular response in the MV range. They would be good candidates forin vivo dosimetry, and quality assurance of VMAT and tomotherapy, and other modalities with beams irradiating from multiple orientations, such as Cyberknife and ViewRay, with minor modifications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hadronization in semi-inclusive deep-inelastic scattering on nuclei.

A series of semi-inclusive deep-inelastic scattering measurements on deuterium, helium, neon, krypton, and xenon targets has been performed in order to study hadronization. The data were collected with the HERMES detector at the DESY laboratory using a 27.6 GeV positron or electron beam. Hadron multiplicities on nucleus A relative to those on the deuteron, R{sub A},{sup h}, are presented for various hadrons ({pi}{sup +}, {pi}{sup -}, {pi}{sup 0}, K{sup +}, K{sup -}, {rho}, and {bar p}) as a function of the virtual-photon energy ?, the fraction z of this energy transferred to the hadron, the photon virtuality Q{sup 2}, and the hadron transverse momentum squared p{sub t}{sup 2}. The data reveal a systematic decrease of R{sub A}{sup h} with the mass number A for each hadron type h. Furthermore, R{sub A}{sup h} increases (decreases) with increasing values of v(z), increases slightly with increasing Q{sup 2}, and is almost independent of p{sub t}{sup 2}, except at large values of p{sub t}{sup 2}. For pions two-dimensional distributions also are presented. These indicate that the dependences of R{sub A}{sup {pi}} on v and z can largely be described as a dependence on a single variable L{sub c}, which is a combination of v and z. The dependence on L{sub c} suggests in which kinematic conditions partonic and hadronic mechanisms may be dominant. The behavior of R{sub A}{sup {pi}} at large p{sub t}{sup 2} constitutes tentative evidence for a partonic energy-loss mechanism. The A-dependence of R{sub A}{sup h} is investigated as a function of v, z, and of L{sub c}. It approximately follows an A* form with * {approx} 0.5-0.6.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-Resolution, Small Animal Radiation Research Platform With X-Ray Tomographic Guidance Capabilities

Purpose: To demonstrate the computed tomography, conformal irradiation, and treatment planning capabilities of a small animal radiation research platform (SARRP). Methods and Materials: The SARRP uses a dual-focal spot, constant voltage X-ray source mounted on a gantry with a source-to-isocenter distance of 35 cm. Gantry rotation is limited to 120{sup o} from vertical. X-rays of 80-100 kVp from the smaller 0.4-mm focal spot are used for imaging. Both 0.4-mm and 3.0-mm focal spots operate at 225 kVp for irradiation. Robotic translate/rotate stages are used to position the animal. Cone-beam computed tomography is achieved by rotating the horizontal animal between the stationary X-ray source and a flat-panel detector. The radiation beams range from 0.5 mm in diameter to 60 x 60 mm{sup 2}. Dosimetry is measured with radiochromic films. Monte Carlo dose calculations are used for treatment planning. The combination of gantry and robotic stage motions facilitate conformal irradiation. Results: The SARRP spans 3 ft x 4 ft x 6 ft (width x length x height). Depending on the filtration, the isocenter dose outputs at a 1-cm depth in water were 22-375 cGy/min from the smallest to the largest radiation fields. The 20-80% dose falloff spanned 0.16 mm. Cone-beam computed tomography with 0.6 x 0.6 x 0.6 mm{sup 3} voxel resolution was acquired with a dose of <1 cGy. Treatment planning was performed at submillimeter resolution. Conclusion: The capability of the SARRP to deliver highly focal beams to multiple animal model systems provides new research opportunities that more realistically bridge laboratory research and clinical translation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acute Skin Toxicity Following Stereotactic Body Radiation Therapy for Stage I Non-Small-Cell Lung Cancer: Who's at Risk?

Purpose: We examined the rate of acute skin toxicity within a prospectively managed database of patients treated for early-stage non-small-cell lung cancer (NSCLC) and investigated factors that might predict skin toxicity. Methods: From May 2006 through January 2008, 50 patients with Stage I NSCLC were treated at Memorial Sloan-Kettering Cancer Center with 60 Gy in three fractions or 44-48 Gy in four fractions. Patients were treated with multiple coplanar beams (3-7, median 4) with a 6 MV linac using intensity-modulated radiotherapy (IMRT) and dynamic multileaf collimation. Toxicity grading was performed and based on the National Cancer Institute Common Terminology Criteria for Adverse Effects. Factors associated with Grade 2 or higher acute skin reactions were calculated by Fisher's exact test. Results: After a minimum 3 months of follow-up, 19 patients (38%) developed Grade 1, 4 patients (8%) Grade 2, 2 patients (4%) Grade 3, and 1 patient Grade 4 acute skin toxicity. Factors associated with Grade 2 or higher acute skin toxicity included using only 3 beams (p = 0.0007), distance from the tumor to the posterior chest wall skin of less than 5 cm (p = 0.006), and a maximum skin dose of 50% or higher of the prescribed dose (p = 0.02). Conclusions: SBRT can be associated with significant skin toxicity. One must consider the skin dose when evaluating the treatment plan and consider the bolus effect of immobilization devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of chemical disorder on radiation-induced defect production and damage evolution in NiFeCoCr

Understanding chemical disorder in many concentrated solid solution alloys (CSAs) at the levels of electrons and atoms has attracted increasing attention as a path forward to reveal and identify underlying mechanisms for extraordinary mechanical properties and improved radiation tolerance. Single-phase NiFeCoCr CSA is a common base for many high-entropy alloys (HEAs) that have shown improved mechanical strength and radiation tolerance. In this study, defect production and damage evolution in NiFeCoCr under ion irradiation at room temperature to dose over 20 dpa are determined using ion channeling technique along both <100> and <110> directions utilizing multiple probing beam energies. The results obtained from the multi-axial and multi-energy channeling analysis are compared with those previously obtained for Ni crystals irradiated under similar conditions. The influence of chemical complexity on defect production and clustering at early-stage under room temperature irradiation up to dose of 1 dpa is discussed based on positron annihilation spectroscopy results. Defect structure evaluation in Ni and NiFeCoCr is also discussed based on transmission electron microscopy results over a prolonged irradiation at both room and elevated temperatures. Compared with chemically complex NiFeCoCr, larger dislocation loops thus less lattice strain are expected to form in pure Ni. Moreover, the role of chemical disorder in this CSA is also investigated based on ab initio calculations using large supercells. Finally, to understand the impact of chemical complexity effect on defect structure evolution, this integrated research effort attempts to link the relatively large charge redistribution due to difference in valence electron counts resulting from alloying different 3d transition metal elements, moderate lattice distortion arising from similar adaptable atomic size, and notable suppressed or delayed damage evolution in NiFeCoCr.

36 MATERIALS SCIENCE↗

Stereotactic body radiation therapy planning with duodenal sparing using volumetric-modulated arc therapy vs intensity-modulated radiation therapy in locally advanced pancreatic cancer: A dosimetric analysis

Stereotactic body radiation therapy (SBRT) achieves excellent local control for locally advanced pancreatic cancer (LAPC), but may increase late duodenal toxicity. Volumetric-modulated arc therapy (VMAT) delivers intensity-modulated radiation therapy (IMRT) with a rotating gantry rather than multiple fixed beams. This study dosimetrically evaluates the feasibility of implementing duodenal constraints for SBRT using VMAT vs IMRT. Non–duodenal sparing (NS) and duodenal-sparing (DS) VMAT and IMRT plans delivering 25 Gy in 1 fraction were generated for 15 patients with LAPC. DS plans were constrained to duodenal D{sub max} of<30 Gy at any point. VMAT used 1 360° coplanar arc with 4° spacing between control points, whereas IMRT used 9 coplanar beams with fixed gantry positions at 40° angles. Dosimetric parameters for target volumes and organs at risk were compared for DS planning vs NS planning and VMAT vs IMRT using paired-sample Wilcoxon signed rank tests. Both DS VMAT and DS IMRT achieved significantly reduced duodenal D{sub mean}, D{sub max}, D{sub 1cc}, D{sub 4%}, and V{sub 20} {sub Gy} compared with NS plans (all p≤0.002). DS constraints compromised target coverage for IMRT as demonstrated by reduced V{sub 95%} (p = 0.01) and D{sub mean} (p = 0.02), but not for VMAT. DS constraints resulted in increased dose to right kidney, spinal cord, stomach, and liver for VMAT. Direct comparison of DS VMAT and DS IMRT revealed that VMAT was superior in sparing the left kidney (p<0.001) and the spinal cord (p<0.001), whereas IMRT was superior in sparing the stomach (p = 0.05) and the liver (p = 0.003). DS VMAT required 21% fewer monitor units (p<0.001) and delivered treatment 2.4 minutes faster (p<0.001) than DS IMRT. Implementing DS constraints during SBRT planning for LAPC can significantly reduce duodenal point or volumetric dose parameters for both VMAT and IMRT. The primary consequence of implementing DS constraints for VMAT is increased dose to other organs at risk, whereas for IMRT it is compromised target coverage. These findings suggest clinical situations where each technique may be most useful if DS constraints are to be employed.

61 RADIATION PROTECTION AND DOSIMETRY↗

A methodology for customizing implantation profiles of light ions using a single thin foil energy degrader

We report a method was developed to quantify the spatial distribution and implantation depth of energy-degraded light ions with a thin foil rotating energy degrader for use during multiple ion beam irradiation. The methodology covers three physical phenomena: ions passing through the thin foil, ions travelling through the vacuum to the target, and ion implantation into the target, and accounts for the distribution of ions both in depth and in plane. The processes of energy straggling and scattering were calculated using SRIM. The effects of raster-scanning, and the geometry of the system were implemented in scripts handling the SRIM output files. Elastic backscattering (EBS) using 2.38 MeV H+ protons was used to measure the helium depth profiles after implantation with and without thin foil energy degradation. Defect analysis with transmission electron microscopy confirmed the implantation profiles measured with EBS and calculated with SRIM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent and intense multibeam generation by the apex of sharp nano-objects: Electron half-circular prism

Mutually coherent multiple electron beams (multibeam) were generated from diffraction at the apex of sharp nano-objects, especially carbon nanotubes, in a field emission projection microscope. Simulation using a simple scalar diffraction model showed that the apex of sharp nano-objects played the role of an electron half-circular prism, deflecting an electron beam through a constant angle toward the prism axis. The multibeam diffraction pattern gave a high visibility of {approx}0.8 and high intensity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a straightness measurement and compensation system with multiple right-angle reflectors and a lead zirconate titanate-based compensation stage

This paper presents a real-time straightness measurement and compensation system with an optical straightness measurement system and a single-axis flexure-hinge type lead zirconate titanate (PZT)-based compensation stage. The optical straightness measurement system consists of a He-Ne laser, a quadrant photodiode detector, and five right-angle reflectors. Multiple laser beam reflections between the right-angle reflectors increase the sensitivity of the straightness measurement by a factor of 6. The right-angle reflectors can be moved by the flexure-hinge type PZT-based compensation stage that is actuated by a PZT actuator to ensure that the laser beam is always projected onto the center of the quadrant detector. These two systems are integrated and fixed on a scanning stage. The resolution of the straightness measurement system is 0.1 {mu}m. Using the real-time straightness compensation system, the straightness error of the scanning stage is fed back to the control system. The compensated straightness error of the scanning stage system was reduced from 6.5 {mu}m to less than 1 {mu}m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Techniques for Handling and Removal of Spectral Channels in Fourier Transform Synchrotron-Based Spectra

Channel spectra are a big problem for those attempting to use synchrotron-based Fourier transform spectra for spectral lineshape studies. Due to the layout of the optical system at the CLS far-infrared beamline, the synchrotron beam undergoes unavoidable multiple reflections on the steering mirrors, beam splitter, several sets of windows, and filters. We present a method for eliminating channel spectra and compare the results of our technique with other methods available in the literature.

43 PARTICLE ACCELERATORS↗

Statistical spatio-temporal properties of the Laser MegaJoule speckle

This paper investigates a statistical model to describe the spatial and temporal properties of hot spots generated by the superimposition of multiple laser beams. In the context of the Laser MegaJoule design, we introduce the formula for contrasts, trajectories and velocities of the speckle pattern. Single bundle of four beams, two-cones and three-cones configurations are considered. Statistical properties of the speckle in the zone where all the beams overlap are studied with different configurations of polarizations. These properties are shown to be very different from the case of one single bundle of four beams. The configuration of polarization has only a slight effect in the two-cones or three cones configuration. Indeed, the impact of the double polarization smoothing is reduced in the area in which all the beams overlap, while it is much more significant when they split. Moreover, the size of the hot-spots decreases as the number of laser beams increases, but we show that their velocity decreases. As a matter of fact, the maximal velocity of hot spots is found to be only about 10{sup -5} of the velocity of light and the integrated contrast is about 15% when the beams overlap.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temporal and spatial effects of ablation plume on number density distribution of droplets in an aerosol measured by laser-induced breakdown

We proposed and experimentally demonstrated a novel method of evaluating the number density of droplets in an aerosol by laser-induced breakdown. The number density of droplets is evaluated from the volume in which the laser intensity exceeds the breakdown threshold intensity for droplets, and the number of droplets in this volume, which is evaluated by the experimentally observed breakdown probability. This measurement method requires a large number of laser shots for not only precise measurement but also highly temporally and spatially resolved density distribution in aerosol. Laser ablation plumes ejected from liquid droplets generated by breakdown disturb the density around the measurement points. Therefore, the recovery time of the density determines the maximum repetition rate of the probe laser irradiating a fixed point. The expansion range of the ablation plume determines the minimum distance at which the measurement points are unaffected by a neighboring breakdown when multiple laser beams are simultaneously irradiated. These laser irradiation procedures enable the measurement of the number density distribution of droplets in an aerosol at a large number of points within a short measurement time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Two-dimensional wave-number spectral analysis techniques for phase contrast imaging turbulence imaging data on large helical device

An analysis method for unfolding the spatially resolved wave-number spectrum and phase velocity from the 2D CO{sub 2} laser phase contrast imaging system on the large helical device is described. This is based on the magnetic shear technique which identifies propagation direction from 2D spatial Fourier analysis of images detected by a 6 × 8 detector array. Because the strongest modes have wave-number at the lower end of the instrumental k range, high resolution spectral techniques are necessary to clearly resolve the propagation direction and hence the spatial distribution of fluctuations along the probing laser beam. Multiple-spatial point cross-correlation averaging is applied before calculating the spatial power spectrum. Different methods are compared, and it is found that the maximum entropy method (MEM) gives best results. The possible generation of artifacts from the over-narrowing of spectra are investigated and found not to be a significant problem. The spatial resolution Δρ (normalized radius) around the peak wave-number, for conventional Fourier analysis, is ∼0.5, making physical interpretation difficult, while for MEM, Δρ ∼ 0.1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronic transport characterization of silicon wafers by spatially resolved steady-state photocarrier radiometric imaging

Spatially resolved steady-state photocarrier radiometric (PCR) imaging technique is developed to characterize the electronic transport properties of silicon wafers. Based on a nonlinear PCR theory, simulations are performed to investigate the effects of electronic transport parameters (the carrier lifetime, the carrier diffusion coefficient, and the front surface recombination velocity) on the steady-state PCR intensity profiles. The electronic transport parameters of an n-type silicon wafer are simultaneously determined by fitting the measured steady-state PCR intensity profiles to the three-dimensional nonlinear PCR model. The determined transport parameters are in good agreement with the results obtained by the conventional modulated PCR technique with multiple pump beam radii.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A compact E × B filter: A multi-collector cycloidal focusing mass spectrometer

A compact E × B mass spectrometer is presented. The mass spectrometer presented is termed a “perfect focus” mass spectrometer as the resolution of the device is independent of both the initial direction and energy of the ions (spatial and energy independent). The mass spectrometer is small in size (∼10.7 in.{sup 3}) and weight (∼2 kg), making it an attractive candidate for portability when using small, permanent magnets. A multi-collector Faraday cup design allows for the detection of multiple ion beams in discrete collectors simultaneously; providing the opportunity for isotope ratio monitoring. The mass resolution of the device is around 400 through narrow collector slits and the sensitivity of the device follows expected theoretical calculations of the ion current produced in the electron impact ion source. Example mass spectra obtained from the cycloidal focusing mass spectrometer are presented as well as information on mass discrimination based on instrumental parameters and isotope ratio monitoring of certain ion signals in separate Faraday cups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Focusability in the multi-pump Raman amplification of short laser pulses

Spatially combining multiple strong laser beams is a promising concept for achieving ultrahigh laser intensities. Proof-of-principle experiments have been conducted at the National Ignition Facility to report a combination of up to 20 pulses with high energy conversion efficiency. However, the combination process might damage the seed focusability due to mismatch of the seed and pump wavefronts. Here, we investigate the effect of the finite pump beam size on the focusability of the seed pulse. We propose an approach to retain and even improve the seed focusability by specifically arranging multiple pump beams. The results are demonstrated by the numerical solution of coupled nonlinear Schrödinger equations. Our findings also apply to seed amplification by filamented pump pulses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗