Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Proceedings from the 2nd International Symposium on Formation Flying Missions and Technologies

Topics discussed include: The Stellar Imager (SI) "Vision Mission"; First Formation Flying Demonstration Mission Including on Flight Nulling; Formation Flying X-ray Telescope in L2 Orbit; SPECS: The Kilometer-baseline Far-IR Interferometer in NASA's Space Science Roadmap Presentation; A Tight Formation for Along-track SAR Interferometry; Realization of the Solar Power Satellite using the Formation Flying Solar Reflector; SIMBOL-X : Formation Flying for High-Energy Astrophysics; High Precision Optical Metrology for DARWIN; Close Formation Flight of Micro-Satellites for SAR Interferometry; Station-Keeping Requirements for Astronomical Imaging with Constellations of Free-Flying Collectors; Closed-Loop Control of Formation Flying Satellites; Formation Control for the MAXIM Mission; Precision Formation Keeping at L2 Using the Autonomous Formation Flying Sensor; Robust Control of Multiple Spacecraft Formation Flying; Virtual Rigid Body (VRB) Satellite Formation Control: Stable Mode-Switching and Cross-Coupling; Electromagnetic Formation Flight (EMFF) System Design, Mission Capabilities, and Testbed Development; Navigation Algorithms for Formation Flying Missions; Use of Formation Flying Small Satellites Incorporating OISL's in a Tandem Cluster Mission; Semimajor Axis Estimation Strategies; Relative Attitude Determination of Earth Orbiting Formations Using GPS Receivers; Analysis of Formation Flying in Eccentric Orbits Using Linearized Equations of Relative Motion; Conservative Analytical Collision Probabilities for Orbital Formation Flying; Equations of Motion and Stability of Two Spacecraft in Formation at the Earth/Moon Triangular Libration Points; Formations Near the Libration Points: Design Strategies Using Natural and Non-Natural Ares; An Overview of the Formation and Attitude Control System for the Terrestrial Planet Finder Formation Flying Interferometer; GVE-Based Dynamics and Control for Formation Flying Spacecraft; GNC System Design for a New Concept of X-Ray Distributed Telescope; GNC System for the Deployment and Fine Control of the DARWIN Free-Flying Interferometer; Formation Algorithm and Simulation Testbed; and PLATFORM: A Formation Flying, RvD and Robotic Validation Test-bench.

Source record↗

Wavefront Sensing With Switched Lenses for Defocus Diversity

In an alternative hardware design for an apparatus used in image-based wavefront sensing, defocus diversity is introduced by means of fixed lenses that are mounted in a filter wheel (see figure) so that they can be alternately switched into a position in front of the focal plane of an electronic camera recording the image formed by the optical system under test. [The terms image-based, wavefront sensing, and defocus diversity are defined in the first of the three immediately preceding articles, Broadband Phase Retrieval for Image-Based Wavefront Sensing (GSC-14899-1).] Each lens in the filter wheel is designed so that the optical effect of placing it at the assigned position is equivalent to the optical effect of translating the camera a specified defocus distance along the optical axis. Heretofore, defocus diversity has been obtained by translating the imaging camera along the optical axis to various defocus positions. Because data must be taken at multiple, accurately measured defocus positions, it is necessary to mount the camera on a precise translation stage that must be calibrated for each defocus position and/or to use an optical encoder for measurement and feedback control of the defocus positions. Additional latency is introduced into the wavefront sensing process as the camera is translated to the various defocus positions. Moreover, if the optical system under test has a large focal length, the required defocus values are large, making it necessary to use a correspondingly bulky translation stage. By eliminating the need for translation of the camera, the alternative design simplifies and accelerates the wavefront-sensing process. This design is cost-effective in that the filterwheel/lens mechanism can be built from commercial catalog components. After initial calibration of the defocus value of each lens, a selected defocus value is introduced by simply rotating the filter wheel to place the corresponding lens in front of the camera. The rotation of the wheel can be automated by use of a motor drive, and further calibration is not necessary. Because a camera-translation stage is no longer needed, the size of the overall apparatus can be correspondingly reduced.

Dean, Bruce H.↗

CCD Camera Lens Interface for Real-Time Theodolite Alignment

Theodolites are a common instrument in the testing, alignment, and building of various systems ranging from a single optical component to an entire instrument. They provide a precise way to measure horizontal and vertical angles. They can be used to align multiple objects in a desired way at specific angles. They can also be used to reference a specific location or orientation of an object that has moved. Some systems may require a small margin of error in position of components. A theodolite can assist with accurately measuring and/or minimizing that error. The technology is an adapter for a CCD camera with lens to attach to a Leica Wild T3000 Theodolite eyepiece that enables viewing on a connected monitor, and thus can be utilized with multiple theodolites simultaneously. This technology removes a substantial part of human error by relying on the CCD camera and monitors. It also allows image recording of the alignment, and therefore provides a quantitative means to measure such error.

Wake, Shane↗

An Independent Orbit Determination Simulation for the OSIRIS-REx Asteroid Sample Return Mission

After arriving at the near-Earth asteroid (101955) Bennu in late 2018, the OSIRIS-REx spacecraft will execute a series of observation campaigns and orbit phases to accurately characterize Bennu and ultimately collect a sample of pristine regolith from its surface. While in the vicinity of Bennu, the OSIRIS-REx navigation team will rely on a combination of ground-based radiometric tracking data and optical navigation (OpNav) images to generate and deliver precision orbit determination products. Long before arrival at Bennu, the navigation team is performing multiple orbit determination simulations and thread tests to verify navigation performance and ensure interfaces between multiple software suites function properly. In this paper, we will summarize the results of an independent orbit determination simulation of the Orbit B phase of the mission performed to test the interface between the OpNav image processing and orbit determination software packages.

Orbit↗

Quantitative Daily Maps of PM 2.5 Episodes for California and Other Regions: Satellite Column Water and Optical Depth as Allied Tracers of Dilution

The Western US and many regions globally present daunting difficulties in understanding PM 2.5 episodes. We evaluate extensions of a method independent of modeled source-description and transport/transformation and using several satellite remote sensing products from imaging spectrometers. The San Joaquin Valley (SJV) especially suffers few-day episodes due to shallow mixing; PM 2.5 retrieval suffers low satellite AOT (Aerosol Optical Thickness) and bright surfaces.Nevertheless, we find residual errors in our maps of of typically 5-8 micrograms per cubic meter. Episodes in the Valley reaching 60-100 micrograms per cubic meter. These maps detail pollution from Interstate 5 at the scale of a few kilometers. The maps are based on NASA's MODerate resolution Imaging Spectrometer (MODIS) data at circa 1 kilometer as processed with the Multi-Angle Implementation of Atmospheric Correction. The Bay Area Air Quality Management District has requested that we test our methods in their challenging environment characterized by multiple sub-basins defined by complex topography. Our tests suggest that nearly similar precision may be expected for wintertime conditions with high PM 2.5 . We note difficulties when measured PM 2.5 is less than 8-10 micrograms per cubic meter, but good relative precision when PM 2.5 rises above 20; i.e. in episodes of concern for morbidity and mortality. Our method stresses physically meaningful functions of MODIS-MAIAC (Multi-Angle Implementation of Atmospheric Correction)-derived AOD (Aerosol Optical Depth) and total water vapor column. A mixed-effects statistical model exploiting existing station data works powerfully to allow us daily AOT-to-PM 2.5 relationships that allow a calibration of the map. In those cases where water vapor and particles have generally similar surface sources, using the ratio of AOT / Column_water can improve the daily calibrations so as to reach our quoted precision. We briefly present some cartoon idealizations that explain this success and also the likely reasons that our mixed effects model (or "daily calibration") works; also when it should not work. The combined satellite/mixed-effects model works best for wintertime San Joaquin Valley episodes, where the meteorology of particle and H2O(v) dilution is quite appropriate. We extended and tested the methodology (a) for the Bay Area wintertime situations and (b) for smoke plume events (e.g. the October 2017 fire events of the Sonoma area). Our SJV work was evaluated using NASA's DISCOVER-AQ (Deriving Information on Surface conditions from Column and Vertically Resolved Observations Relevant to Air Quality) airborne measurements, and by season- long measurements in Fresno. If the composition and size distribution of the aerosols can be assessed for the regions we describe, retrievals should have improved accuracy.

Chatfield, Robert B.↗

RHIC spin flipper AC dipole controller

The RHIC Spin Flipper's five high-Q AC dipoles which are driven by a swept frequency waveform require precise control of phase and amplitude during the sweep. This control is achieved using FPGA based feedback controllers. Multiple feedback loops are used to and dynamically tune the magnets. The current implementation and results will be presented. Work on a new spin flipper for RHIC (Relativistic Heavy Ion Collider) incorporating multiple dynamically tuned high-Q AC-dipoles has been developed for RHIC spin-physics experiments. A spin flipper is needed to cancel systematic errors by reversing the spin direction of the two colliding beams multiple times during a store. The spin flipper system consists of four DC-dipole magnets (spin rotators) and five AC-dipole magnets. Multiple AC-dipoles are needed to localize the driven coherent betatron oscillation inside the spin flipper. Operationally the AC-dipoles form two swept frequency bumps that minimize the effect of the AC-dipole dipoles outside of the spin flipper. Both AC bumps operate at the same frequency, but are phase shifted from each other. The AC-dipoles therefore require precise control over amplitude and phase making the implementation of the AC-dipole controller the central challenge.

43 PARTICLE ACCELERATORS↗

High-precision micro/nano-scale machining system

A high precision micro/nanoscale machining system. A multi-axis movement machine provides relative movement along multiple axes between a workpiece and a tool holder. A cutting tool is disposed on a flexible cantilever held by the tool holder, the tool holder being movable to provide at least two of the axes to set the angle and distance of the cutting tool relative to the workpiece. A feedback control system uses measurement of deflection of the cantilever during cutting to maintain a desired cantilever deflection and hence a desired load on the cutting tool.

42 ENGINEERING↗

Multimuons in cosmic-ray events as seen in ALICE at the LHC

ALICE is a large experiment at the CERN Large Hadron Collider. Located 52 meters underground, its detectors are suitable to measure muons produced by cosmic-ray interactions in the atmosphere. In this paper, the studies of the cosmic muons registered by ALICE during Run 2 (2015–2018) are described. The analysis is limited to multimuon events defined as events with more than four detected muons (N μ > 4) and in the zenith angle range 0° < θ < 50°. The results are compared with Monte Carlo simulations using three of the main hadronic interaction models describing the air shower development in the atmosphere: QGSJET-II-04, EPOS-LHC, and SIBYLL 2.3d. The interval of the primary cosmic-ray energy involved in the measured muon multiplicity distribution is about 4 × 10 15 < E prim < 6 × 10 16 eV. In this interval none of the three models is able to describe precisely the trend of the composition of cosmic rays as the energy increases. However, QGSJET-II-04 is found to be the only model capable of reproducing reasonably well the muon multiplicity distribution, assuming a heavy composition of the primary cosmic rays over the whole energy range, while SIBYLL 2.3d and EPOS-LHC underpredict the number of muons in a large interval of multiplicity by more than 20% and 30%, respectively. The rate of high muon multiplicity events (N μ > 100) obtained with QGSJET-II-04 and SIBYLL 2.3d is compatible with the data, while EPOS-LHC produces a significantly lower rate (55% of the measured rate). For both QGSJET-II-04 and SIBYLL 2.3d, the rate is close to the data when the composition is assumed to be dominated by heavy elements, an outcome compatible with the average energy E prim ∼ 10 17 eV of these events. This result places significant constraints on more exotic production mechanisms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Predicting cancer rates in astronauts from animal carcinogenesis studies and cellular markers

The radiation space environment includes particles such as protons and multiple species of heavy ions, with much of the exposure to these radiations occurring at extremely low average dose-rates. Limitations in databases needed to predict cancer hazards in human beings from such radiations are significant and currently do not provide confidence that such predictions are acceptably precise or accurate. In this article, we outline the need for animal carcinogenesis data based on a more sophisticated understanding of the dose-response relationship for induction of cancer and correlative cellular endpoints by representative space radiations. We stress the need for a model that can interrelate human and animal carcinogenesis data with cellular mechanisms. Using a broad model for dose-response patterns which we term the "subalpha-alpha-omega (SAO) model", we explore examples in the literature for radiation-induced cancer and for radiation-induced cellular events to illustrate the need for data that define the dose-response patterns more precisely over specific dose ranges, with special attention to low dose, low dose-rate exposure. We present data for multiple endpoints in cells, which vary in their radiosensitivity, that also support the proposed model. We have measured induction of complex chromosome aberrations in multiple cell types by two space radiations, Fe-ions and protons, and compared these to photons delivered at high dose-rate or low dose-rate. Our data demonstrate that at least three factors modulate the relative efficacy of Fe-ions compared to photons: (i) intrinsic radiosensitivity of irradiated cells; (ii) dose-rate; and (iii) another unspecified effect perhaps related to reparability of DNA lesions. These factors can produce respectively up to at least 7-, 6- and 3-fold variability. These data demonstrate the need to understand better the role of intrinsic radiosensitivity and dose-rate effects in mammalian cell response to ionizing radiation. Such understanding is critical in extrapolating databases between cellular response, animal carcinogenesis and human carcinogenesis, and we suggest that the SAO model is a useful tool for such extrapolation.

Non-NASA Center↗

3D Integrated Sensing Solutions

We will present the proposed research project to develop 3D-integrated sensors using advanced manufacturing capability for novel sensors, heterogeneously integrated with energy efficient readout circuits. The lack of precision timing in particle tracking detectors and the absence of low power, high throughput communications solutions to read them out limits progress in multiple fields of fundamental science. The aim of the project is to develop technology to enable large-scale particle detectors with 3D-integrated ASIC designs to simultaneously achieve 10 μm position resolution and 10 ps precision timing, with low-power consumption and high throughput rates. This research program leverages the unique combination of facilities and cross-disciplinary expertise of scientists and engineers at SLAC, FNAL, and LLNL and industrial partners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unifying Gene Expression Measures from Multiple Platforms Using Factor Analysis

In the Cancer Genome Atlas (TCGA) project, gene expression of the same set of samples is measured multiple times on different microarray platforms. There are two main advantages to combining these measurements. First, we have the opportunity to obtain a more precise and accurate estimate of expression levels than using the individual platforms alone. Second, the combined measure simplifies downstream analysis by eliminating the need to work with three sets of expression measures and to consolidate results from the three platforms. We propose to use factor analysis (FA) to obtain a unified gene expression measure (UE) from multiple platforms. The UE is a weighted average of the three platforms, and is shown to perform well in terms of accuracy and precision. In addition, the FA model produces parameter estimates that allow the assessment of the model fit. The R code is provided in File S2. Gene-level FA measurements for the TCGA data sets are available from http://tcga-data.nci.nih.gov/docs/publications/unified_expression/.

59 BASIC BIOLOGICAL SCIENCES↗

Multiple spherically converging shock waves in liquid deuterium

To achieve ignition, inertial confinement fusion target designs use a sequence of shocks to compress the target before it implodes. To minimize the entropy acquired by the fuel, the strength and timing of these shocks will be precisely set during a series of tuning experiments that adjust the laser pulse to achieve optimal conditions. We report measurements of the velocity and timing of multiple, converging shock waves inside spherical targets filled with liquid (cryogenic) deuterium. These experiments produced the highest reported shock velocity observed in liquid deuterium (U{sub s} = 135 km/s at {approx}25 Mb) and observed an increase in shock velocity due to spherical convergence. These direct-drive experiments are best simulated when hydrodynamic codes use a nonlocal model for the transport of absorbed laser energy from the coronal plasma to the ablation surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Orbiter camera payload system's large-format camera and attitude reference system

The Orbiter camera payload system (OCPS) is an integrated photographic system carried into earth orbit as a payload in the Space Transportation System (STS) Orbiter vehicle's cargo bay. The major component of the OCPS is a large-format camera (LFC), a precision wide-angle cartographic instrument capable of producing high-resolution stereophotography of great geometric fidelity in multiple base-to-height ratios. A secondary and supporting system to the LFC is the attitude reference system (ARS), a dual-lens stellar camera array (SCA) and camera support structure. The SCA is a 70 mm film system that is rigidly mounted to the LFC lens support structure and, through the simultaneous acquisition of two star fields with each earth viewing LFC frame, makes it possible to precisely determine the pointing of the LFC optical axis with reference to the earth nadir point. Other components complete the current OCPS configuration as a high-precision cartographic data acquisition system. The primary design objective for the OCPS was to maximize system performance characteristics while maintaining a high level of reliability compatible with rocket launch conditions and the on-orbit environment. The full OCPS configuration was launched on a highly successful maiden voyage aboard the STS Orbiter vehicle Challenger on Oct. 5, 1984, as a major payload aboard the STS-41G mission.

Schardt, B. B.↗

The detector system of the Daya Bay reactor neutrino experiment

The Daya Bay experiment was the first to report simultaneous measurements of reactor antineutrinos at multiple baselines leading to the discovery of ν¯e oscillations over km-baselines. Subsequent data has provided the world's most precise measurement of sin 2 2θ 13 and the effective mass splitting Δm 2 ee . The experiment is located in Daya Bay, China where the cluster of six nuclear reactors is among the world's most prolific sources of electron antineutrinos. Multiple antineutrino detectors are deployed in three underground water pools at different distances from the reactor cores to search for deviations in the antineutrino rate and energy spectrum due to neutrino mixing. Instrumented with photomultiplier tubes, the water pools serve as shielding against natural radioactivity from the surrounding rock and provide efficient muon tagging. Arrays of resistive plate chambers over the top of each pool provide additional muon detection. The antineutrino detectors were specifically designed for measurements of the antineutrino flux with minimal systematic uncertainty. Relative detector efficiencies between the near and far detectors are known to better than 0.2%. With the unblinding of the final two detectors’ baselines and target masses, a complete description and comparison of the eight antineutrino detectors can now be presented. This study describes the Daya Bay detector systems, consisting of eight antineutrino detectors in three instrumented water pools in three underground halls, and their operation through the first year of eight detector data-taking.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Model-Independent Determination of Nuclear Weak Form Factors and Implications for Standard Model Precision Tests

We analyze the recoil corrections in superallowed beta decays of T = 1, J P = 0 + nuclei by fixing the mean square charged weak radius model independently using the data of multiple charge radii across the nuclear isotriplet. By comparing to model estimations, we argue that the existing theory uncertainty in the statistical rate function f might have been substantially underestimated. Here, we discuss the implications of our proposed strategy for precision tests of the standard model, including a potential alleviation of the first-row CKM unitarity deficit, and motivate new experiments for charge radii measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiple Scattering Measurements in the MICE Experiment

The international Muon Ionization Cooling Experiment (MICE), under construction at RAL, will test a prototype cooling channel for a future Neutrino Factory or Muon Collider. The cooling channel aims to achieve, using liquid hydrogen absorbers, a 10% reduction in transverse emittance. The change in 4D emittance will be determined with an accuracy of 1% by measuring muons individually. Step IV of MICE will make the first precise emittance-reduction measurements of the experiment. Simulation studies using G4MICE, based on GEANT4, find a significant difference in multiple scattering in low Z materials, compared with the standard expression quoted by the Particle Data Group. Direct measurement of multiple scattering using the scintillating-fibre trackers is found to be possible, but requires the measurement resolution to be unfolded from the data.

43 PARTICLE ACCELERATORS↗

The ASLOTS concept: An interactive, adaptive decision support concept for Final Approach Spacing of Aircraft (FASA). FAA-NASA Joint University Program

This presentation outlines a concept for an adaptive, interactive decision support system to assist controllers at a busy airport in achieving efficient use of multiple runways. The concept is being implemented as a computer code called FASA (Final Approach Spacing for Aircraft), and will be tested and demonstrated in ATCSIM, a high fidelity simulation of terminal area airspace and airport surface operations. Objectives are: (1) to provide automated cues to assist controllers in the sequencing and spacing of landing and takeoff aircraft; (2) to provide the controller with a limited ability to modify the sequence and spacings between aircraft, and to insert takeoffs and missed approach aircraft in the landing flows; (3) to increase spacing accuracy using more complex and precise separation criteria while reducing controller workload; and (4) achieve higher operational takeoff and landing rates on multiple runways in poor visibility.

Simpson, Robert W.↗

Optimizing a Multiple Right-Hand Side Dslash Kernel for Intel Knights Corner

Lattice Quantum Chromo-dynamics (LQCD) stands unique as the only computationally tractable, non-perturbative, and model-independent quantum field theory of the strong nuclear force. LQCD achieves tractability by discretizing our familiar 4-dimensional space-time onto a hypercubic lattice. The core component of the linear solver used in LQCD is the Wilson-Dirac operator whose finite difference component is called the Dslash operator. Dslash is a nearest neighbor stencil operator summing matrix-vector multiplications over lattice points. The arithmetic intensity of a regular Dslash operator acting on a single vector in single precision is between 0.88-2.29 (depending on the tricks employed) making it memory bandwidth bound on most current architectures, including Xeon Phi. Maximizing the performance of Dslash on Xeon Phi requires deliberate exploitation of its architectural features. One key feature of Xeon Phi is its powerful vector processing unit with lengthy vector registers. There is a class of LQCD computations which aims to solve the Dirac equation for the same lattice gauge fields multiple times. In this case one can gain additional reuse of the gauge field, and potentially simplified vectorization, through applying Dslash to several vectors at the same time; often referred to as Multiple Right Hand Side (MRHS) Dslash. Previous work in this area focused on applying this approach to the Highly Improved Staggered operator, and in cases to the multi-Grid algorithm for Wilson clover fermions. Here, we present two approaches to MRHS Dslash: a vector register blocking approach and one using the software package QPhiX with a custom Code Generator for low-level intrinsics. We explore the Knights Corner instruction set, memory hierarchy, and threading capabilities. For standard lattice sizes used in testing, we observed significant speedups, with sustained performance of over 700 GFLOPS (single precision) in one instance. We achieved up to 27% of theoretical peak performance compared to a maximum of 12% obtained by the previous single RHS method in QPhiX.

Joó, Bálint↗