Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutrons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Improved Neutron Lifetime Measurement with UCN$\tau$

In this work, we report an improved measurement of the free neutron lifetime $\tau_n$ using the UCN$\tau$ apparatus at the Los Alamos Neutron Science Center. We count a total of approximately 38×10 6 surviving ultracold neutrons (UCNs) after storing in UCN$\tau$’s magnetogravitational trap over two data acquisition campaigns in 2017 and 2018. We extract $\tau$ n from three blinded, independent analyses by both pairing long and short storage time runs to find a set of replicate $\tau$ n measurements and by performing a global likelihood fit to all data while self-consistently incorporating the β-decay lifetime. Both techniques achieve consistent results and find a value $\tau$ n =877.75±0.28 stat +0.22/–0.16 syst s. With this sensitivity, neutron lifetime experiments now directly address the impact of recent refinements in our understanding of the standard model for neutron decay.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

IMAGINE: The neutron protein crystallography beamline at the high flux isotope reactor

IMAGINE is a high intensity, quasi-Laue neutron crystallography beamline developed at the 85 MW High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). This state-of-the-art facility for neutron-diffraction enables neutron protein structures to be determined at or near atomic resolutions from crystals with volumes of < 1 mm 3 and unit cell edges of < 150 Å. The beamline features include elliptical focusing mirrors that deliver neutrons into a 2.0 × 3.2 mm 2 focal spot at the sample position, and variable short and long wavelength cutoff optics that provide automated exchange between multiple wavelength configurations. The beamline is equipped with a single-axis goniometer, neutron-sensitive cylindrical image plate detector and room temperature and cryogenic sample environments. This article describes the beamline components, the diffractometer and the data collection and data analysis protocols that are used, and outlines the protein deuteration, crystallization and conventional crystallography capabilities that are available to users at ORNL's neutron facilities. We also present examples of the scientific questions being addressed at this beamline and highlight important findings in enzyme chemistry that have been made possible by IMAGINE.

59 BASIC BIOLOGICAL SCIENCES↗

The importance of delayed neutron precursors in gamma dose calculations for activated primary heat exchanger components in the Molten Salt Breeder Reactor

The Molten Salt Reactor (MSR) Multiphysics Applications technical area in the Nuclear Energy Advanced Modeling and Simulation program has supported the development of 3D Monte Carlo models of the Molten Salt Breeder Reactor (MSBR) over the last couple of years. This MSBR model was previously run with the Shift Monte Carlo code to perform radiation shielding calculations in the reactor cell area. The MSBR is a 2250 MWth (1000 MWe) liquid-fueled molten salt reactor design developed at Oak Ridge National Laboratory in the 1970s. Determining the source terms from activated primary heat exchanger (HX) components is important because delayed and prompt neutron fluxes incident on these components affect the dose rate in the primary HX maintenance areas. This information can be used in the development of remote handling procedures required during shutdown for maintenance. A methodology has been developed and is proposed in this paper to quantify the activated source term from the primary HX components as a result of the movement of the delayed neutron precursors in flowing primary fuel salt through the primary HXs in the MSBR. The goal of this research is to evaluate the gamma dose rates in the maintenance hatches above the primary HX using the activated HX source terms. The study showed that the gamma dose rates are approximately two orders of magnitudes higher when accounting for the neutron activation from the movement of delayed neutron precursors through the HXs than when flowing fuel is not considered. Thus, the movement of delayed neutron precursors must be taken into account for accurately predicting the neutron activation of primary loop components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Uranium integral fission product yields for a spectrally-shaped 14.1 MeV neutron source at the National Ignition Facility

This paper describes the experimental results for an energy tuning assembly created to modify the National Ignition Facility deuterium–tritium fusion neutron source into a notional thermonuclear and prompt fission neutron spectrum, which has applications in integral measurements, nuclear data benchmarks, and radiation effects on microelectronics. The Monte Carlo neutron transport utilized MCNP5 to estimate the ETA-modified fluence using the ENDF-B/VIII.0 and IRDFF-II continuous energy nuclear data libraries, and SCALE Sampler was used to estimate the systematic nuclear data covariance using ENDF-B/VII.1 and IRDFF-II in a 252-group structure. The experiment fielded eight activation foils and a highly enriched uranium sample. This provided fifteen reaction channels that were used in a forward-fit comparison to the modeled results and to unfold the neutron spectrum using STAYSL. Gamma-ray spectrometry was performed on the activation and highly enriched uranium foils, and the reduced Χ 2 between the modeled and experimental values was 1.21. The results from the STAYSL unfold, reduced Χ 2 = 1.62, indicated that the modeled neutron spectrum was achieved and the systematic nuclear data uncertainty associated with the neutron transport and activation product cross sections was representative of the experiment. Integral cumulative fission product yield data were collected for 37 mass chains with a combination of gamma-ray spectrometry and radiochemical analysis. Fission product analysis was generally in agreement with two models using a semi-empirical fit and the General Observables of Fission code, with the exception of mass chains 88, 109, 111, 112, 113, 129, 139, 142, 144, 151, and 156.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Effect of rhenium addition on deuterium retention in neutron-irradiated tungsten

In this work, the effects of rhenium (Re) addition on deuterium (D) retention in neutron-irradiated tungsten (W) were investigated. Pure W and W-5Re (5 at.%) alloy samples were irradiated with neutrons at High Flux Isotope Reactor using MFE-RB-19 J capsule. The sample temperature and the damage level were 864 K and 0.35 dpa for pure W and 792 K and 0.26 dpa for W-5Re alloy. A portion of the samples was exposed to D plasma at Tritium Plasma Experiment at Idaho National Laboratory at 823 K to a fluence of 5 × 1025 m -2 . Vacancy-type defects in neutron-irradiated samples were examined using positron annihilation spectroscopy (PAS); D retention after plasma exposure was evaluated by thermal desorption spectrometry (TDS). TDS measurements revealed that D retention in the neutron-irradiated W-5Re alloy was similar to that in the unirradiated W sample, whereas a significant increase in D retention was observed in neutron-irradiated W. Thus, Re addition significantly suppressed the increase in D retention after neutron irradiation. This effect was attributed to the suppression of vacancy-type defect formation, as confirmed by PAS.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Back to functional hydrides: Effects of neutron-irradiated microstructure on hydrogen retention in yttrium hydride

Functional hydrides are promising candidates for advanced nuclear reactors, particularly in portable or transportable applications, due to their high hydrogen-retention capabilities, enabling efficient neutron moderation, and compact reactor design. However, hydrogen mobility in hydrides at elevated irradiation temperatures poses significant technological challenges, necessitating a comprehensive understanding of their irradiation behavior. Furthermore, this study investigated the microstructural and chemical stability of neutron-irradiated yttrium hydrides to assess their hydrogen-retention capacity. A targeted literature review was also conducted to contextualize neutron-irradiation effects on functional hydrides with regards to structural stability and hydrogen retention. Experimental characterizations revealed that, at high temperatures, irradiated hydrides retained their phase stability, which was likely enhanced by irradiation-induced microstructure evolution. Notably, an amorphous yttrium and oxygen -rich surface layer was present at the free surface of the hydride. Its thickness decreased while a continuous crystalline Y-O-rich layer was formed with increasing neutron damage. Additionally, the number density of dislocation loops and cavities generally increased as a function of neutron dose. First-principles calculations of hydrogen behavior within yttrium vacancy clusters in yttrium hydrides demonstrated vacancy-size-dependent hydrogen stability and configuration, highlighting the role of vacancy geometry in regulating hydrogen retention. Thus, the presence of irradiation-induced dislocation loops and cavities were hypothesized to improve hydrogen retention. Collectively, these findings advance the understanding of hydride behavior under neutron irradiation as well as their technological readiness for portable or transportable nuclear reactors.

Defect clusters↗

Neutron diffraction probing hydrogen in monoclinic H 2 VOPO 4

Light hydrogen atoms are resolvable with neutrons; however, the massive incoherent background inhibits the diffraction quality. To improve the signal, isotope treatment by deuteration becomes a prerequisite for a successful crystallographic understanding of hydrogen-containing materials by neutron diffraction. Thanks to the low-background and high-resolution time-of-flight neutron diffractometer, this work demonstrates a direct and successful measurement of high-quality neutron diffraction patterns of H 2 VOPO 4 powders, a precursor of a high-capacity alkali-ion battery cathode. The Rietveld refinement identifies the hydrogen coordinates, occupancy, and thermal parameters in the H 2 VOPO 4 lattice. Finally, the result highlights the unique capability of neutron diffraction for the structure characterization of hydrogen-containing materials, potentially without requiring costly and possibly artifact-inducing deuteration for neutron diffraction.

36 MATERIALS SCIENCE↗

Anomalous neutron nuclear-magnetic interference spectroscopy

The electron–phonon interaction plays a critical role in materials’ electrical, thermal, optical, and superconducting properties. However, measuring the phonon mode-resolved electron–phonon interaction has been challenging. Here we propose neutron-scattering-based Anomalous Neutron nUclear-Magnetic Interference Spectroscopy (ANUBIS), where the co-existence of neutron nuclear scattering and magnetic scattering leads to anomalous dynamical structure factor under the presence of the electron–phonon interaction. Such anomalous structure factor is linear in electron–phonon coupling constant at the phonon wavevector, and is directly proportional to the momentum and energy-resolved dielectric function. The experimental configuration can be achieved using existing polarized inelastic neutron scattering setup, and an order-of-magnitude estimate shows the viability to observe the anomalous scattering signal is around to 10 –4 to 10 –3 relative to phonon scattering, which is examined through the preliminary experiments and achievable at emerging neutron facilities. As a result, our proposal offers an alternative neutron-based metrology to probe the crucial electronic properties.

Electron-phonon interactions↗

Applications of HPGe-detected high energy gamma rays toward quantifying neutron emission rates and 234 U enrichment in UF 6 cylinders

This study presents a 234 U enrichment meter that uses high energy gamma and neutron count rate as measured by a portable, high-purity germanium gamma ray detector. Twenty-one 30B cylinders containing UF 6 of varying origin were analyzed with an HPGe detector for high-energy gamma ray and neutron counts. Excellent correlations (R 2 0.95) between various regions of 3.0 MeV gamma rays, neutron count rate, and uranium enrichment were found. These neutron and high-energy gamma data are used to create calibration-dependent enrichment meters for 234 U. The 234 U enrichment calculated from the neutron count rate and 4 – 6 MeV gamma count rate is more accurate than methods that rely on the 120.9 keV peak which is strongly attenuated inside commercial sized UF 6 cylinders. These neutron and high-energy gamma enrichment calculators can also be used to determine a 235 U enrichment, assuming mass-based enrichment from natural uranium, but the results are not as accurate as the traditional 185.7 keV peak enrichment meter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First evaluation of fast neutron imaging with LiInSe 2 semiconductors

Fast neutron imaging is a powerful tool to investigate elemental/isotopic compositions of objects, supporting both scientific studies as well as cargo scanning. Current neutron imaging systems are faced with challenges associated with timing, detection efficiency, and/or spatial resolution. Here, we report on the use of a semiconducting lithium indium diselenide neutron sensor coupled to a Timepix ASIC for fast neutron imaging. Using a 15 cm thick copper knife edge, the spatial resolution of the neutron imager was found to be 1.55 mm for 9 MeV neutrons. In conclusion, the experimental detection efficiency at 9 MeV was in general agreement with calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of D–D fusion neutrons generated in nanowire array laser plasma using Timepix3 detector

Here, we present results of the neutron detection in laser plasma experiment with CD2 nanowire target. A hybrid semiconductor pixel detector Timepix3 covered with neutron converters was using for the detection neutrons. D-D fusion neutrons were detected in a plastic converter through recoiled protons. Both the energy of recoiled protons and time-of-flight of neutrons (and thus their energy) were determined. We report (2.4±1.8) × 10 7 neutrons generated for 1 J of incoming laser energy. Furthermore, we proved that Timepix3 is suitable for difficult operational conditions in laser experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of a boron-loaded deuterated liquid scintillator for fast and thermal neutron detection

The preparation and characterization of novel boron-loaded deuterated liquid scintillators (BLDLS) are presented for the first time to investigate the performance of a detector sensitive to both fast and thermal neutrons intended for future neutron spectroscopy measurements. Three deuterated toluene-based scintillation cocktails were produced, one without boron, one loaded with ortho-carborane (natural boron isotopic abundance), and one with 96 wt% 10B enriched ortho-carborane. General optical and material properties were analyzed to include the composition, density, index of refraction, photoluminescence emission spectra, and absorbance spectra in addition to the relative light yield, resolution, relative efficiency, and pulse-shape-discrimination performance for all three scintillators and a hydrogen-based EJ-309 scintillator to evaluate the effects of boron loading in comparison with a common commercially-available scintillator and feasibility for future neutron spectroscopy measurements. Finally, the detection of shielded neutron sources was explored to capitalize on the 10B thermal neutron capture reaction. The results showed loading the scintillators with boron deteriorated the PSD performance slightly compared to the unloaded deuterated scintillator and resulted in a relative light yield loss of 26% and 41% for the 10B enriched and natural boron BLDLS, respectively. Lastly, the BLDLS have a higher relative detection efficiency than the unloaded deuterated scintillator for shielded neutron sources, based on total count rate, a desirable characteristic for missions related to finding and characterizing illicitly-trafficked special nuclear material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Application of recoil-imaging time projection chambers to directional neutron background measurements in the SuperKEKB accelerator tunnel

Gaseous time projection chambers (TPCs) with high readout segmentation are capable of reconstructing detailed 3D ionization distributions of nuclear recoils resulting from elastic neutron scattering. Here, using a system of six compact TPCs with pixel ASIC readout, filled with a 70:30 mixture of He:CO 2 gas, we analyze the first directional measurements of beam-induced neutron backgrounds in the tunnel regions surrounding the Belle II detector at the SuperKEKB e + e – collider. With the use of 3D recoil tracking, we show that these TPCs are capable of maintaining nearly 100% nuclear recoil purity to reconstructed ionization energies (E reco ) as low as 5 keV ee . Using a large sample of Monte-Carlo (MC)-simulated 4 He, 12 C, and 16 O recoil tracks, we find consistency between predicted and measured recoil energy spectra in five of the six TPCs, providing useful validation of the neutron production mechanisms modeled in simulation. Restricting this sample to 4 He recoil tracks with E reco > 40 keV ee , we further demonstrate axial angular resolutions within 8° and we introduce a procedure that under suitable conditions, correctly assigns the vector direction to 91% of these simulated 4 He recoils. Applying this procedure to assign vector directions to measured 4 He recoil tracks, we observe consistency between the angular distributions of observed and simulated recoils, providing first experimental evidence of localized neutron “hotspots” in the accelerator tunnel. Observed rates of nuclear recoils in these TPCs suggest that simulation overestimates the neutron flux from these hotspots. Despite this, we estimate these hotspots to produce the majority of neutron backgrounds in the accelerator tunnel at SuperKEKB’s target luminosity of 6.3 x 10 35 cm –2 s –1 , making them important regions to continue to monitor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thick target neutron yields from Beryllium, Carbon, Tungsten, and Lead targets irradiated by 26.7 MeV/nucleon 4 H e ions

The angular and energy distributions of secondary neutrons produced from 26.7 MeV/nucleon 4 He ions, stopping in thick Be, C, W and Pb targets are measured by the time of flight method. The GEANT4, PHITS, and FLUKA Monte Carlo simulation codes with different physics models are employed to simulate the neutron yields and the results are compared with the experimental data. For the thick Be and C targets, GEANT4 with INCL++ reproduces the experimental data reasonably well. Whereas PHITS with JQMD-2.0 overestimates the neutron yields at intermediate energies and FLUKA with PEANUT underestimated the neutron yields at intermediate energies. For W and Pb targets, FLUKA with PEANUT physics model agree with experimental data best. PHITS with JQMD-2.0 overestimates the neutron yield at intermediate energies at 0°, and GEANT4 with INCL++ underestimates the neutron yield at intermediate energies at three angles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing secondary neutrons at BLIP for isotope production applications

Fast secondary neutrons created at the Brookhaven Linac Isotope Producer (BLIP) facility following proton irradiation were characterized by the foil activation technique and compared with FLUKA Monte Carlo simulations. The FLUKA-simulated neutron flux was spectrally adjusted following the maximum entropy formalism using the International Reactor Dosimetry and Fusion File (IRDFF-II), with predictions agreeing with experimental measurements to within 9 % following the adjustment procedure. Here, a multitude of degrader configurations were simulated to assess the feasibility of improving the fast (E n > 20 MeV) secondary neutron yield at the proposed neutron target position (“N-slot”). A configuration where the N-slot is closest to the proton degrader produced the highest fast neutron yield, with tungsten degraders achieving the best performance. Assuming the optimized target-degrader configuration proposed in this work, we discuss potential isotope production opportunities with secondary neutrons. In most cases the yields are in the order of several mCi.

07 ISOTOPE AND RADIATION SOURCES↗

Development and testing of a fission-like neutron field for dosimetry and instrument calibrations based on deuterium-tritium generator

For nearly five decades 252 Cf sources have been used for testing and calibration over a wide range of neutron detection devices used for nuclear safety and radiation protection. However, the vastly increased cost of 252 Cf sources, its short half-life, and concerns about future shortage have prompted nuclear facilities and radiological calibration laboratories that rely on high-intensity neutron sources to seek alternatives. There appear to be no other radionuclide neutron sources that would match “like-to-like” 252 Cf performance characteristics. Alternatives of producing a fission-like neutron spectrum based on commercially available deuterium-tritium (D-T) generators, and without any fissionable materials or beryllium, have been explored. This paper describes efforts of designing the spectrum shaping assembly, its construction and installation. The produced neutron field was evaluated both from the perspective of the neutron fluence spectrum and the resulting dosimetric outcome. Finally, it was tested for practical application by examining response of various health physics instruments and personal monitoring devices in comparison to the response of those devices when exposed to 252 Cf. In conclusion, the response of survey-type instruments tested within the prototype, surrogate fission, reference field are acceptably close to their response in the targeted 252 Cf field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutronics Calculation Advances at Los Alamos: Manhattan Project to Monte Carlo

The history and advances of neutronics calculations at Los Alamos during the Manhattan Project through the present are reviewed. Substantial improvements to neutron diffusion methods and the invention of both the Monte Carlo neutron transport methods in 1947 and deterministic discrete ordinates Sn in 1953 were all made at Los Alamos just after the Manhattan Project. We briefly summarize early simpler and more approximate neutronics methods and then describe the need to better predict neutronics behavior through consideration of theoretical equations, models and algorithms, experimental measurements, and available computing capabilities and their limitations. This paper briefly covers key advances in deterministic methods during the Manhattan Project. These capabilities, coupled with increasing postwar defense needs and the invention of electronic computing with the Electronic Numeric Integrator and Computer, known as ENIAC, and the Mathematical Analyzer Numerical Integrator and Automatic Computer Model, known as MANIAC, led to the creation of Monte Carlo and deterministic discrete ordinates neutronics transport methods. We note the important role that the scientific comradery between the Los Alamos scientists played in the process. This paper briefly covers the early methods, algorithms, computers, and electronic and women pioneers that enabled Monte Carlo to spread to all areas of science. We focus heavily on these early developments and the subsequent creation of the MCNP® code, advances in its associated nuclear data, and its applications to problems of national defense at Los Alamos.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Total Scattering Analysis of Materials for the Nuclear Fuel Cycle

Here, this paper reviews recent experimental efforts at the University of Tennessee and Oak Ridge National Laboratory to comprehensively characterize the structural details of materials relevant for the nuclear fuel cycle by employing advanced neutron scattering techniques. For the study of nuclear ceramics, neutron scattering offers distinct advantages over traditional laboratory or synchrotron X-ray diffraction, including enhanced sensitivity to elements with a low atomic mass, such as oxygen, nitrogen, and carbon. The key to these efforts is the recent advancement in the neutron scattering infrastructure at the high-flux diffractometers at the Spallation Neutron Source. The high neutron flux at these instruments enables neutron total scattering, a nondestructive bulk technique that simultaneously captures both short-range structural effects through pair distribution function analysis and long-range order through diffraction pattern analysis. This approach is particularly important for a comprehensive description of defective, disordered, or amorphous nuclear materials. The case studies presented here include analyses of the local defect structure in hyperstoichiometric uranium oxides and short-range order of ion-irradiated ceramics. This advanced analytical methodology will improve our understanding of the behavior of materials in extreme environments and contribute to the development of more resilient nuclear materials.

Neutron scattering↗