Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Photoinduced Dynamics with Constrained Vibrational Motion: FrozeNM Algorithm

Ab initio molecular dynamics (AIMD) simulation, analyzed in terms of vibrational normal modes, is a widely used technique that facilitates understanding of complex structural motions and coupling between electronic and nuclear degrees of freedom. Usually, only a subset of vibrations is directly involved in the process of interest. The impact of these vibrations can be evaluated by performing AIMD simulations by selectively freezing certain motions. In this paper, we present frozen normal mode (FrozeNM), a new algorithm to apply normal-mode constraints in AIMD simulations, as implemented in the nonadiabatic excited state molecular dynamics code. We further illustrate its capacity by analyzing the impact of normal-mode constraints on the photoinduced energy transfer between polyphenylene ethynylene dendrimer building blocks. Our results show that the electronic relaxation can be significantly slowed down by freezing a well-selected small subset of active normal modes characterized by their contributions in the direction of energy transfer. The application of these constraints reduces the nonadiabatic coupling between electronic excited states during the entire dynamical simulations. Furthermore, we validate reduced dimensionality models by freezing all the vibrations, except a few active modes. Altogether, we consider FrozeNM as a useful tool that can be broadly used to underpin the role of vibrational motion in a studied process and to formulate reduced models that describe essential physical phenomena.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Excited-State Bond Contraction and Charge Migration in a Platinum Dimer Complex Characterized by X-ray and Optical Transient Absorption Spectroscopy

Interactions between metal centers in dimeric transition metal complexes (TMCs) play important roles in their excited-state energetics and pathways, and, thus, affect their photophysical properties relevant to their applications, e.g., photoluminescent materials and photocatalysis. In this study, we report electronic and nuclear structural dynamics studies of two photoexcited pyrazolate-bridged [Pt(ppy)(µ-R 2 pz)] 2 -type Pt(II) dimers (ppy = 2-phenylpyridine, µ-R 2 pz = 3,5-substituted pyrazolate): [Pt(ppy)(µ-H 2 pz)] 2 (1) and [Pt(NDI-ppy)(µ-Ph 2 pz)] 2 (2, NDI = 1,4,5,8-naphthalenediimide), both of which have distinct ground state Pt-Pt distances. X-ray transient absorption spectroscopy at the Pt L III -edge revealed a new d-orbital vacancy due to the one-electron oxidation of the Pt centers in 1 and 2. However, while a transient Pt-Pt contraction was observed in 2, such an effect was completely absent in 1, demonstrating how the excited states of these complexes are determined by the overlap of the Pt (d z 2 ) orbitals, which is tuned by steric bulk of the pyrazolate R-groups in the 3- and 5-positions. In tandem with analysis of the Pt-Pt distance structural parameter, we observed photoinduced charge separation in 2 featuring a covalently linked NDI acceptor on the ppy ligand. The formation and subsequent decay of the NDI radical anion absorption signals were detected upon photoexcitation using optical transient absorption spectroscopy. The NDI radical anion decayed on the same timescale, hundreds of picoseconds, as that of the d-orbital vacancy signal of the oxidized Pt-Pt core observed in the XTA measurements. The data indicated ultrafast formation of the charge-separated state and subsequent charge recombination to the original Pt(II-II) species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Large Hyperfine Coupling Arising from Pseudo- 2 S Ground States in a Series of Lutetium(II) Metallocene Complexes

The synthesis of molecules with strong coupling between electronic and nuclear spins represents an important challenge in molecular quantum information science. Here, we report the synthesis and characterization of the divalent lutetium metallocene complexes Lu(Cp Me 5 )(Cp iPr 5 ) (Cp Me 5 = pentamethylcyclopentadienyl; Cp iPr 5 = pentaisopropylcyclopentadienyl), Lu(Cp iPr 4 Et ) 2 (Cp iPr 4 Et = ethyltetraisopropylcyclopentadienyl), and Lu(Cp iPr 4 ) 2 (Cp iPr 4 = tetraisopropylcyclopentadienyl). The molecular structures of these complexes, as determined through singlecrystal X-ray diffraction, feature a common bent sandwich geometry, with average Cp–Lu–Cp angles ranging from 159.9° to 152.6°. Analysis of continuous-wave electron paramagnetic resonance (EPR) spectra for the complexes reveals nearly isotropic g tensors with only a slight deviation from that of a free electron. Moreover, an extremely large splitting of the eight-line spectra indicates the presence of strong hyperfine coupling, and simulations provide isotropic hyperfine coupling constants of A iso = 4.38, 4.30, and 4.17 GHz across the series, where the value of A iso is found to decrease as the Cp–Lu–Cp angle becomes more acute. Notably, these values are the largest yet observed for any lanthanide complex. Moreover, EPR and computational analysis show that the large values of A iso stem from large s-orbital character up to 41.2% in the corresponding singly occupied molecular orbitals. To our knowledge, this degree of s-character in a molecular orbital is the largest yet reported for an open-shell isolable complex. These results outline a general strategy toward the isolation of paramagnetic molecules with strong hyperfine coupling and highly isotropic doublet electronic ground states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A MGy radiation-hardened sensor instrumentation link for nuclear reactor monitoring and remote handling

Decommissioning, dismantling and remote handling applications in nuclear facilities all require robotic solutions that are able to survive in radiation environments. Recently raised safety, radiation hardness and cost efficiency demands from both the nuclear regulatory and the society impose severe challenges in traditional methods. For example, in case of the dismantling of the Fukushima sites, solutions that survive accumulated doses higher than 1 MGy are mandatory. To allow remote operation of these tools in nuclear environments, electronics were used to be shielded with several centimeters of lead or even completely banned in these solutions. However, shielding electronics always leads to bulky and heavy solutions, which reduces the flexibility of robotic tools. It also requires longer repair time and produces extra waste further in a dismantling or decommissioning cycle. In addition, often in current reactor designs, due to size restrictions and the need to inspect very tight areas there are limitations to the use of shielding. A MGy radiation-hardened sensor instrumentation link developed by MAGyICS provides a solution to build a flexible, easy removable and small I and C module with MGy radiation tolerance without any shielding. Hereby it removes all these pains to implement electronics in robotic tools. The demonstrated solution in this poster is developed for ITER Remote Handling equipments operating in high radiation environments (>1 MGy) in and around the Tokamak. In order to obtain adequately accurate instrumentation and control information, as well as to ease the umbilical management, there is a need of front-end electronics that will have to be located close to those actuators and sensors on the remote handling tool. In particular, for diverter remote handling, it is estimated that these components will face gamma radiation up to 300 Gy/h (in-vessel) and a total dose of 1 MGy. The radiation-hardened sensor instrumentation link presented here, consists of multiple in-house developed, state-of-the-art building blocks. They have all been assessed and characterized up to a dose higher than 1 MGy. The first block in the signal chain is a smaller than 1 uV offset, low noise instrumentation amplifier that has a programmable gain between 8 and 256. This amplifier is followed by a high precision 16 bit ADC. Its main function is to digitize the amplified signal coming from the amplifier. The output of the ADC is a serial digital data stream. The next block is a 8 channel digital multiplexer. It converts the 8 digital data streams into 1 digital data stream. Hereby the instrumentation solution reduces the number of cables from 16 to 1 (8* 2 analogue differential signals). In addition, the multiplexer modules can be combined with other modules to reduce even further the number of cables. Every instrumentation solution requires a stable high precision voltage reference. Therefore also a bandgap reference has been developed and assessed under gamma irradiation. A low jitter, 10 MHz clock generator has been developed and qualified to clock the ADC and the multiplexer with high accuracy. Finally, an on-chip radiation-hard temperature sensor is also included. A complete remote, real-time test setup was prepared by MAGyICS in cooperation with Fusion for Energy to qualify the sensor instrumentation link at SCK-CEN. It is qualified by closely following the ESCC22900 space standard for electronics used in a radiation environment. The main benefit of the sensor instrumentation solution discussed here is that it can be directly employed in a MGy-level accumulated dose radiation environment, therefore it can digitize and multiplex sensor readout values early in the signal chain. Hereby the sensor values are not distorted by external interferences on the long transmission cable. Moreover it allows readout and digitize multiple low-bandwidth sensors ( pressure and temperature sensors, thermocouples, angular resolvers and LVDTs). Hence these instrumentation modules can be used to follow the trend of the digitalization in the nuclear industry. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Two-Component Multireference Restricted Active Space Configuration Interaction for the Computation of L-Edge X-ray Absorption Spectra

X-ray absorption spectroscopy is a powerful probe of local electronic and nuclear structure, providing insights into chemical processes. The theoretical prediction and interpretation of metal L-edge X-ray absorption spectra is complicated by both relativistic effects, including spin-orbit coupling, and by the multiconfigurational nature of the states involved. This work details an exact two-component multireference restricted active space configuration interaction (X2C-MRRASCI) scheme that uses an exact two-component state average complete active space self-consistent-field method (X2C-SA-CASSCF), which includes the spin-orbit coupling in a variational manner, for the accurate description of the electronic structure before using a restricted active space configuration interaction method to describe the core excited states of the X-ray spectrum. Benchmark calculations are presented for a series of iron containing complexes, with results showing key features of the spectrum being reproduced, including ligand to metal charge transfer and shake-up excitations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrafast energy redistribution in C{sub 60} fullerenes: A real time study by two-color femtosecond spectroscopy

Strong-field excitation and energy redistribution dynamics of C{sub 60} fullerenes are studied by means of time-resolved mass spectrometry in a two-color femtosecond pump-probe setup. Resonant pre-excitation of the electronic system via the first dipole-allowed HOMO{yields}LUMO+1(t{sub 1g}) (HOMO denotes highest occupied molecular orbital and LUMO denotes lowest unoccupied molecular orbital) transition with ultrashort 25 fs pulses at 399 nm of some 10{sup 12} W cm{sup -2} results in a highly nonequilibrium distribution of excited electrons and vibrational modes in the neutral species. The subsequent coupling among the electronic and nuclear degrees of freedom is monitored by probing the system with time-delayed 27 fs pulses at 797 nm of some 10{sup 13} W cm{sup -2}. Direct information on the characteristic relaxation time is derived from the analysis of transient singly and multiply charged parent and fragment ion signals as a function of pump-probe delay and laser pulse intensity. The observed relaxation times {tau}{sub el}{approx_equal}60-400 fs are attributed to different microcanonical ensembles prepared in the pre-excitation process and correspond to different total energy contents and energy sharing between electronic and vibrational degrees. The characteristic differences and trends allow one to extract a consistent picture for the formation dynamics of ions in different charge states and their fullerenelike fragments and give evidence to collective effects in multiple ionization such as plasmon-enhanced energy deposition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion velocity effect governs damage annealing process in defective KTaO 3

Effects of electronic to nuclear energy losses (S e /S n ) ratio on damage evolution in defective KTaO 3 have been investigated by irradiating pre-damaged single crystal KTaO 3 with intermediate energy O ions (6 MeV, 8 MeV and 12 MeV) at 300 K. By exploring these processes in pre-damaged KTaO 3 containing a fractional disorder level of 0.35, the results demonstrate the occurrence of a precursory stage of damage production before the onset of damage annealing process in defective KTaO 3 that decreases with O ion energy. The observed ionization-induced annealing process by ion channeling analysis has been further mirrored by high resolution transmission electron microscopy analysis. In addition, the reduction of disorder level is accompanied by the broadening of the disorder profiles to greater depth with increasing ion fluence, and enhanced migration is observed with decreasing O ion energy. Since S e (~3.0 keV nm –1 ) is nearly constant for all 3 ion energies across the pre-damaged depth, the difference in behavior is due to the so-called 'velocity effect': the lower ion velocity below the Bragg peak yields a confined spread of the electron cascade and hence an increased energy deposition density. Here, the inelastic thermal spike calculation has further confirmed the existence of a velocity effect, not previously reported in KTaO 3 or very scarcely reported in other materials for which the existence of ionization-induced annealing has been reported. In other words, understanding of ionization-induced annealing has been advanced by pointing out that ion velocity effect governs the healing of pre-existing defects, which may have significant implication for the creation of new functionalities in KTaO 3 through atomic-level control of microstructural modifications, but may not be limited to KTaO 3 .

74 ATOMIC AND MOLECULAR PHYSICS↗

High intensity x-ray interaction with a model bio-molecule system: double-core-hole states and fragmentation of formamide

Formamide, a simple model bio-molecule (HCONH 2 ), is irradiated with high intensity, ultrashort pulses from an x-ray free electron laser. Ionic fragments resulting from photoionization and subsequent decay processes are recorded, as well as the electronic signature of the different inner shell ionization events that can take place during the x-ray pulses. Additionally, the formation of double-core-hole states, where a second inner shell electron is removed before the first core hole has been refilled is observed in the electron spectra, recorded at all three sites (C, N, O) of the molecule. The individual ionization potentials are compared with results of ab initio calculations at different level of theory. Based on our results, future opportunities for advanced studies of inner-shell-induced electronic and nuclear dynamics are explored.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hyperfine-mediated static polarizabilities of monovalent atoms and ions

We apply relativistic many-body methods to compute static differential polarizabilities for transitions inside the ground-state hyperfine manifolds of monovalent atoms and ions. Knowledge of this transition polarizability is required in a number of high-precision experiments, such as microwave atomic clocks and searches for CP-violating permanent electric dipole moments. While the traditional polarizability arises in the second order of interaction with the externally applied electric field, the differential polarizability involves an additional contribution from the hyperfine interaction of atomic electrons with nuclear moments. We derive formulas for the scalar and tensor polarizabilities including contributions from magnetic dipole and electric quadrupole hyperfine interactions. Numerical results are presented for Al, Rb, Cs, Yb{sup +}, Hg{sup +}, and Fr.

74 ATOMIC AND MOLECULAR PHYSICS↗

Mechanisms of ion irradiation induced ordering in amorphous TiO 2 nanotubes: Effects of ion mass and energy

Here, amorphous TiO 2 nanotubes were irradiated in-situ in a transmission electron microscope (TEM) with Kr + ions at energies of 46 keV, 150 keV, and 1 MeV and with 46 keV Xe + ions, to investigate the structural and morphological evolution of the nanotubes under irradiation. At all irradiation conditions, amorphous TiO 2 nanotubes exhibited significant morphological instability, and tended to undergo volumetric swelling with increasing ion counts, often until collapse of the original nanotube structure. Molecular dynamics (MD) simulations confirmed that irradiation-induced defects can explain the observed swelling. Structurally, nanotubes remain amorphous following all Kr + irradiation conditions, but irradiation with 46 keV Xe + leads to the formation of anatase nanocrystallites. Importantly, through systematically varying ion energy and ion species, we try to elucidate the influence of nuclear and electronic stopping power on ion irradiation induced changes. By contextualizing these results within the existing literature, we propose that the observed changes in TiO 2 nanotube morphology and structure could be due to a competition between two mechanisms: (1) disorder-induced swelling and (2) irradiation-induced amorphous-to-crystalline transformation.

36 MATERIALS SCIENCE↗

Ultrafast Relaxation of MLCT Excited States in Manganese Tricarbonyl Complexes: Insights from Polarization-Resolved Femtosecond X-ray Absorption Spectroscopy at the Mn and Br K-Edges

Optical absorption features that are often described as metal-to-ligand charge transfer (MLCT) bands underlie the utility of many metal coordination complexes by harnessing the energy of light to drive otherwise inaccessible chemical reactions. Excitation of these bands triggers rapid electronic dynamics that can be challenging to understand, due to complicated potential energy landscapes and highly correlated electronic and nuclear degrees of freedom in metal-containing compounds. The lowest-energy absorption bands in Mn complexes containing alpha-diimine, carbonyl, and halide ligands are particularly interesting, due to the delocalized nature of charge transfer upon excitation. Here, in this study, we report experimental ultrafast dynamics measurements for the series of compounds Mn­(CO) 3 ( R bpy)Br ( R bpy = 4,4′-disubstituted-2,2′-bipyridine; R = H, CF 3 , or NO 2 ) using polarization-resolved, femtosecond X-ray absorption spectroscopy (XAS) at both the Mn and Br K edges. The appearance of a new absorption feature in the Br pre-edge spectrum upon optical excitation reveals the instantaneous formation of an electronic hole that is partially localized on the Br atom and has a lifetime that depends on the electron withdrawing character of the R bpy ligand. For two of the complexes (R = H or CF 3 ), a large expansion of the Mn–Br distance results in a rapid redistribution of the hole and a corresponding decrease in anisotropy of the absorption feature within 50 fs, after which the absorption into the hole disappears on a time scale shorter than 300 fs. We observe a different result for the NO 2 substituted compound, for which the Mn–Br bond contracts and the absorption into the Br-centered hole persists beyond the 2 ps time scale of our measurement. The Mn pre-edge spectrum also reveals structural changes for these three complexes, but the new Mn absorption features become evident only after the nuclei respond to the initial excitation, which allows mixing of Mn 3d and 4p orbitals. The combined use of ultrafast Mn and Br K-edge spectroscopy provides unique insight into the ways in which bipyridine substitution alters the excited-state dynamics, including a very different structural response for the most strongly electron withdrawing substituent.

Otolski, Christopher J. [Univ. of Kansas, Lawrence↗

Detection of astrophysical neutrinos at prospective locations of dark matter detectors

We study the prospects for detection of solar, atmospheric neutrino, and diffuse supernova neutrino background (DSNB) fluxes at future large-scale dark matter detectors through both electron and nuclear recoils. We specifically examine how the detection prospects change for several prospective detector locations [Sanford Underground Research Facility (SURF), SNOlab, Gran Sasso, China Jinping Underground Laboratory (CJPL), and Kamioka] and improve upon the statistical methodologies used in previous studies. Because of its ability to measure lower neutrino energies than other locations, we find that the best prospects for the atmospheric neutrino flux are at the SURF location, while the prospects are weakest at CJPL because it is restricted to higher neutrino energies. On the contrary, the prospects for the DSNB are best at CJPL, due largely to the reduced atmospheric neutrino background at this location. Including full detector resolution and efficiency models, the CNO component of the solar flux is detectable via the electron recoil channel with exposures of ∼ 10 3 ton-yr for all locations. These results highlight the benefits for employing two detector locations, one at high and one at low latitude. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Theory and Simulation of Ultrafast Multidimensional Nonlinear X-ray Spectroscopy of Molecules (Final Report)

Emerging X-ray free electron laser (XFEL) beam sources offer new types of probes of matter with unprecedented spatial and temporal resolutions. These experimental advances must be met by robust theoretical and computational tools that provide predictive modeling capacity of the underlining electronic and structural dynamics. The latter will be essential for the design of sophisticated multi-pulse experiments and for their interpretation. The proposed research effort will focus on developing cutting- edge simulation tools for nonlinear multidimensional X-ray/optical spectroscopies and aims to address key questions in Priority Research Opportunities 1 (Probing and controlling electron motion within a molecule) and 3 (Capturing rare events and intermediate states in the transformation of matter) as mentioned in the BES Roundtable Report “Opportunities for Basic Research at the Frontiers of XFEL Ultrafast Science”. XFEL multidimensional nonlinear techniques, which combine sequences of X-ray and possibly optical pulses, provide a unique experimental toolbox for probing the dynamics of core and valence electronic excitations, as well as material structure. Predictive modeling of these dynamical processes requires the combination of analytical theory for nonlinear interactions of light and matter, robust quantum-chemical methodologies for the accurate description of electronic structure of various materials, and multiscale ab initio electron and nuclear dynamics techniques operating beyond Born-Oppenheimer approximation. These challenges will be addressed with three research thrusts (i) Develop and implement theoretical apparatus for modeling a broad range of multidimensional spectroscopic techniques enabled by present and upcoming XFEL facilities. This thrust also includes the incorporation of a computational module in the DOE supported open-source NWChem computational chemistry package as well as the development of other open-source codes ready for dissemination across a broad user base; (ii) Propose and design new multi-pulse experiments that make use of the capabilities of the incoming LCLS-II facility; (iii) Perform selected applications to specific molecular systems that can be carried out at LCLS-II and demonstrate how these X-ray sources may be used to study nonadiabatic dynamics through conical interactions, electronic correlations in multi-core excitons, and charge transfer/energy transfer processes. The proposed research will be carried out by a multi-disciplinary four-institution research team which combines academia and national laboratories and spans the broad and necessary expertise in theoretical spectroscopy, nonlinear optics, quantum chemistry, molecular non-adiabatic dynamics and code development. The work will be performed in a highly interactive team environment with junior researchers shared between institutions thus cementing cross- disciplinary interactions. The developed simulation tools will be immediately deployed for XFEL facility users, both experimentalists and theorists, via freely distributed codes and databases. Altogether, this project will facilitate establishing XFEL-based multidimensional spectroscopies as a novel diagnostic tool for monitoring electronic and structural dynamics in molecular materials.

74 ATOMIC AND MOLECULAR PHYSICS↗

Enhanced Electron-Phonon Coupling at Metal Surfaces

The Born-Oppenheimer approximation (BOA) decouples electronic from nuclear motion, providing a focal point for most quantum mechanics textbooks. However, a multitude of important chemical, physical and biological phenomena are driven by violations of this approximation. Vibronic interactions are a necessary ingredient in any process that makes or breaks a covalent bond, for example, conventional catalysis or enzymatically delivered biological reactions. Metastable phenomena associated with defects and dopants in semiconductors, oxides, and glasses entail violation of the BOA. Charge exchange in inorganic polymers, organic slats and biological systems involves charge- induced distortions of the local structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low energy electron/recoil discrimination for directional Dark Matter detection

Directional detection is a promising Dark Matter search strategy. Even though it could accommodate to a sizeable background contamination, electron/recoil discrimination remains a key and challenging issue as for direction-insensitive detectors. The measurement of the 3D track may be used to discriminate electrons from nuclear recoils. While a high rejection power is expected above 20 keV ionization, a dedicated data analysis is needed at low energy. After identifying discriminant observables, a multivariate analysis, namely a Boosted Decision Tree, is proposed, enabling an efficient event tagging for Dark Matter search. We show that it allows us to optimize rejection while keeping a rather high efficiency which is compulsory for rare event search.With respect to a sequential analysis, the rejection is about ∼ 20 times higher with a multivariate analysis, for the same Dark Matter exclusion limit.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration methodology for proportional counters applied to yield measurements of a neutron burst

This paper introduces a methodology for the yield measurement of a neutron burst using neutron proportional counters. This methodology is to be applied when single neutron events cannot be resolved in time by nuclear standard electronics, or when a continuous current cannot be measured at the output of the counter. The methodology is based on the calibration of the counter in pulse mode, and the use of a statistical model to estimate the number of detected events from the accumulated charge resulting from the detection of the burst of neutrons. The model is developed and presented in full detail. For the measurement of fast neutron yields generated from plasma focus experiments using a moderated proportional counter, the implementation of the methodology is herein discussed. An experimental verification of the accuracy of the methodology is presented. An improvement of more than one order of magnitude in the accuracy of the detection system is obtained by using this methodology with respect to previous calibration methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Nature of the Long-Lived Excited State in a Ni II Phthalocyanine Complex Investigated by X-Ray Transient Absorption Spectroscopy

The nature of the photoexcited state of octabutoxy nickel(II) phthalocyanine (NiPcOBu8) with a 500ps lifetime was investigated by X-ray transient absorption (XTA) spectroscopy. Previous optical, vibrational, and computational studies have suggested that this photoexcited state has a ligand-to-metal charge transfer (LMCT) nature. By using XTA, which provides unambiguous information on the local electronic and nuclear configuration around the Ni center, the nature of the excited state of NiPcOBu8 was reassessed. Using X-ray probe pulses from a synchrotron source, the ground- and excited-state X-ray absorption spectra of NiPcOBu 8 were measured. Based on the results, we identified that the excited state exhibits spectral features that are characteristic of a Ni-1,Ni-3(3d(z2),3d(x2-y2)) state rather than a LMCT state with a transiently reduced Ni center. This state resembles the (d,d) state of nickel(II) tetramesitylphorphyrin. The XTA features are rationalized based on the inherent cavity sizes of the macrocycles. These results may provide useful guidance for the design of photocatalysts in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optically detected magnetic resonance imaging

Optically detected magnetic resonance provides ultrasensitive means to detect and image a small number of electron and nuclear spins, down to the single spin level with nanoscale resolution. Despite the significant recent progress in this field, it has never been combined with the power of pulsed magnetic resonance imaging techniques. Here, we demonstrate how these two methodologies can be integrated using short pulsed magnetic field gradients to spatially encode the sample. This result in what we denote as an 'optically detected magnetic resonance imaging' technique. It offers the advantage that the image is acquired in parallel from all parts of the sample, with well-defined three-dimensional point-spread function, and without any loss of spectroscopic information. In addition, this approach may be used in the future for parallel but yet spatially selective efficient addressing and manipulation of the spins in the sample. Such capabilities are of fundamental importance in the field of quantum spin-based devices and sensors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗