Search NASA⌕ Search

SEARCH · Search NASA

Results for “occupancy estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Series of compositions Bi{sub 2}(M'{sub x}M{sub 1-x}){sub 4}O{sub 9} (M', M=Al, Ga, Fe; 0{<=}x{<=}1) with mullite-type crystal structure: Synthesis, characterization and {sup 18}O/{sup 16}O exchange experiment

Series of compositions Bi{sub 2}(M'{sub x}M{sub 1-x}){sub 4}O{sub 9} with x=0.0, 0.1,..., 1.0 and M'/M=Ga/Al, Fe/Al and Fe/Ga were synthesized by dissolving appropriate amounts of corresponding metal nitrate hydrates in glycerine, followed by gelation, calcination and final heating at 800 {sup o}C for 24 h. The new compositions with M'/M=Ga/Al form solid-solution series, which are isotypes to the two other series M'/M=Fe/Al and Fe/Ga. The XRD data analysis yielded in all cases a linear dependence of the lattice parameters related on x. Rietveld structure refinements of the XRD patterns of the new compounds, Bi{sub 2}(Ga{sub x}Al{sub 1-x}){sub 4}O{sub 9} reveal a preferential occupation of Ga in tetrahedral site (4 h). The IR absorption spectra measured between 50 and 4000 cm{sup -1} of all systems show systematic shifts in peak positions related to the degree of substitution. Samples treated in {sup 18}O{sub 2} atmosphere (16 h at 800 {sup o}C, 200 mbar, 95% {sup 18}O{sub 2}) for {sup 18}O/{sup 16}O isotope exchange experiments show a well-separated IR absorption peak related to the M-{sup 18}O{sub c}-M vibration, where O{sub c} denotes the common oxygen of two tetrahedral type MO{sub 4} units. The intensity ratio of M-{sup 18}O{sub c}/M-{sup 16}O{sub c} IR absorption peaks and the average crystal sizes were used to estimate the tracer diffusion coefficients of polycrystalline Bi{sub 2}Al{sub 4}O{sub 9} (D=2x10{sup -22} m{sup 2}s{sup -1}), Bi{sub 2}Fe{sub 4}O{sub 9} (D=5x10{sup -21} m{sup 2}s{sup -1}), Bi{sub 2}(Ga/Al){sub 4}O{sub 9} (D=2x10{sup -21} m{sup 2}s{sup -1}) and Bi{sub 2}Ga{sub 4}O{sub 9} (D=2x10{sup -20} m{sup 2}s{sup -1}). - Graphical abstract: Fig. Perspective view of the mullite-type Bi{sub 2}(M'{sub x}M{sub 1-x}){sub 4}O{sub 9} unit cell (M', M=Al, Ga, Fe). Display Omitted

36 MATERIALS SCIENCE↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improved estimate of electron capture rates on nuclei during stellar core collapse

Electron captures on nuclei play an important role in the dynamics of the collapsing core of a massive star that leads to a supernova explosion. Recent calculations of these capture rates were based on microscopic models which account for relevant degrees of freedom. Due to computational restrictions such calculations were limited to a modest number of nuclei, mainly in the mass range A = 45-110. Recent supernova simulations show that this pool of nuclei, however, omits the very neutron-rich and heavy nuclei which dominate the nuclear composition during the last phase of the collapse before neutrino trapping. Assuming that the composition is given by Nuclear Statistical Equilibrium we present here electron capture rates for collapse conditions derived from individual rates for roughly 2700 individual nuclei. For those nuclei which dominate in the early stage of the collapse, the individual rates are derived within the framework of microscopic models, while for the nuclei which dominate at high densities we have derived the rates based on the Random Phase Approximation with a global parametrization of the single particle occupation numbers. In addition, we have improved previous rate evaluations by properly including screening corrections to the reaction rates into account.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Getting to the Heart of Cardiovascular Risk Assessment in Astronauts for Exploration Class Missions

Since the beginning of manned spaceflight, NASA has recognized the potential risk of cardiovascular decrements due to stressors in the space environment. Of particular concern is the effect of space radiation on cardiovascular disease since astronauts will be exposed to higher levels of galactic cosmic rays outside the Earth's protective magnetosphere. To date, only a few studies have examined the effects of heavy ion radiation on cardiovascular disease, and at lower, space-relevant doses, the association between radiation exposure and cardiovascular pathology is more varied and unclear. Furthermore, other spaceflight conditions such as microgravity, circadian shifts, and confinement stress pose unique challenges in estimating the health risks that can be attributed to exposure to ionizing radiations. In this work, we review age, cause of mortality, and radiation exposure amongst early NASA astronauts in selection groups and discuss the limitations of assessing such a cohort when attempting to characterize the risk of space flight, including stressors such as space radiation and microgravity exposure, on cardiovascular health. METHODS: NASA astronauts in selection groups 1-7 were chosen and the comparison population was white men of the same birth cohort as drawn from data from the CDC Wonder Database and CDC National Center for Health Statistics Life Tables. Cause of death information was obtained from the Lifetime Surveillance of Astronaut Health program and deceased astronauts were classified based on ICD-10 codes: ischemic heart disease (IHD), stroke, cancer, acute occupational events, non-NASA accidents, and other/unknown. Expected years of life left and expected age at death were calculated for the cohort. RESULTS AND CONCLUSIONS: There were 32 deaths in this early astronaut population, 12 of which were due to accidents or acute occupational events that impacted lifespan considerably. The average age at death from these causes is 30 years lower than the average expected ~70 years of age in the general population. Remarkably, all 41 living early astronauts outlived our calculated expected age at death for members of their birth cohort; furthermore, 13 of the 20 deceased astronauts who did not die in NASA/non-NASA accidents exceeded this age. There was no difference in IHD between the astronaut cohort and the comparison population; therefore, it is not possible to associate IHD mortality with radiation in that astronaut cohort. As NASA looks toward future exploration-class missions, early astronaut cohorts provide a convenient option for assessing these risks and for developing mitigation strategies. However, many challenges still exist when assessing such limited evidence, including small cohort size, health and lifestyle confounders (such as smoking and drinking), the high accident mortality rate, and the fact that many of these astronauts are still alive, outliving many of their birth-cohort peers. Future analysis should include a longitudinal study, monitoring cases as they occur in the cohort. As this cohort is currently followed-up over time, and as more IHD cases are anticipated in a population of this age, this type of study is not as resource-intensive as would normally be the case.

Elgart, S. R.↗

Prototype Systems for Measuring Outdoor Air Intake Rates in Rooftop Air Handlers

The widespread absence of systems for real-time measurement and feedback control, of minimum outdoor air intake rates in HVAC systems contributes to the poor control of ventilation rates in commercial buildings. Ventilation rates affect building energy consumption and influence occupant health. The project designed fabricated and tested four prototypes of systems for measuring rates of outdoor air intake into roof top air handlers. All prototypes met the ±20% accuracy target at low wind speeds, with all prototypes accurate within approximately ±10% after application of calibration equations. One prototype met the accuracy target without a calibration. With two of four prototype measurement systems, there was no evidence that wind speed or direction affected accuracy; however, winds speeds were generally below usually 3.5 m s -1 (12.6 km h -1 ) and further testing is desirable. The airflow resistance of the prototypes was generally less than 35 Pa at maximum RTU air flow rates. A pressure drop of this magnitude will increase fan energy consumption by approximately 4%. The project did not have resources necessary to estimate costs of mass produced systems. The retail cost of components and materials used to construct prototypes ranged from approximately $1,200 to $1,700. The test data indicate that the basic designs developed in this project, particularly the designs of two of the prototypes, have considerable merit. Further design refinement, testing, and cost analysis would be necessary to fully assess commercial potential. The designs and test results will be communicated to the HVAC manufacturing community.

42 ENGINEERING↗

Dark Energy Survey Year 3 Results: Galaxy mock catalogs for BAO analysis

The calibration and validation of scientific analysis in simulations is a fundamental tool to ensure unbiased and robust results in observational cosmology. In particular, mock galaxy catalogs are a crucial resource to achieve these goals in the measurement of baryon acoustic oscillation (BAO) in the clustering of galaxies. Here we present a set of 1952 galaxy mock catalogs designed to mimic the Dark Energy Survey Year 3 BAO sample over its full photometric redshift range 0.6 < zphoto < 1.1. The mocks are based upon 488 ICE-COLA fast N-body simulations of full-sky light cones and were created by populating halos with galaxies, using a hybrid halo occupation distribution – halo abundance matching model. This model has ten free parameters, which were determined, for the first time, using an automatic likelihood minimization procedure. We also introduced a novel technique to assign photometric redshift for simulated galaxies, following a two-dimensional probability distribution with VIMOS Public Extragalactic Redshift Survey data. The calibration was designed to match the observed abundance of galaxies as a function of photometric redshift, the distribution of photometric redshift errors, and the clustering amplitude on scales smaller than those used for BAO measurements. An exhaustive analysis was done to ensure that the mocks reproduce the input properties. Finally, mocks were tested by comparing the angular correlation function w(θ), angular power spectrum Cℓ, and projected clustering ξp(r⊥) to theoretical predictions and data. The impact of volume replication in the estimate of the covariance is also investigated. The success in accurately reproducing the photometric redshift uncertainties and the galaxy clustering as a function of redshift render this mock creation pipeline as a benchmark for future analyses of photometric galaxy surveys.Key words: catalogs / large-scale structure of Universe / galaxies: distances and redshifts / Galaxy: halo / methods: numerical

79 ASTRONOMY AND ASTROPHYSICS↗

Optical and photoelectrical properties of AgCd{sub 2}GaS{sub 4} single-crystal compounds

The poorly known AgCd{sub 2}GaS{sub 4} single-crystal compounds that crystallize in a rhombic structure (space group Pmn2{sub 1}) are studied. Deviations from the stoichiometric composition of the samples and random occupation of the cation sublattice sites by Ag and Ga ions result in violation of long-range order in the atomic arrangement and make the AgCd{sub 2}GaS{sub 4} compounds structurally closer to disordered systems. In this case, it is found that the fundamental optical-absorption edge is smeared and shifted to longer wavelengths, and is adequately described by the Urbach rule. In addition, a broadening of the spectral peaks of photoconductivity and luminescence is observed. The concentration of charged point defects responsible for the smearing of the absorption edge is calculated. It is found to be 1.2x10{sup 20} cm{sup -3}. The AgCd{sub 2}GaS{sub 4} single crystals are photosensitive semiconductors. From the position of the absorption edge, the optical band gap of the compound is estimated (E{sub g0} = 2.28 eV at T = 297 K). The photoluminescence spectra of the AgCd{sub 2}GaS{sub 4} single crystals are similar to the spectra of defect-containing CdS single crystals; for the AgCd{sub 2}GaS{sub 4} crystals, the emission peaks are shifted to longer wavelengths with respect to the peaks for CdS crystals by {delta}{lambda} = 0.06-0.1 {mu}m. From the analysis of the experimental data, some conclusions on the nature of photoactive centers in AgCd{sub 2}GaS{sub 4} compounds are drawn.

36 MATERIALS SCIENCE↗

[Protein turnover during and after extended space flight]

A 15N-glycine tracer technique was used to study protein turnover in four Russian cosmonauts and two U.S. astronauts who had spent long time aboard the Russian orbital station MIR. As was shown, in space flight protein synthesis falls by 46% on the average, which substantially exceeds estimations made on the basis of data about bed-rested human subjects. Reduction in protein synthesis during space flight is connected with the negative energy balance; therefore, it appears imperative to keep balance between energy intake (foodstuffs) and expenditure by cosmonauts on long-term mission.

manned↗

Public Housing: A Tailored Approach to Energy Retrofits - Raleigh

More than 1 million U.S. Department of Housing and Urban Development-supported public housing units provide rental housing for eligible low-income families across the country. These units range from scattered single-family houses to high-rise apartments. In this project, the Advanced Residential Integrated Energy Solutions Collaborative (ARIES) worked with two public housing authorities (PHAs) to develop packages of energy efficiency retrofit measures the PHAs can cost-effectively implement with their own staffs in the normal course of housing operations at the time when units are refurbished between occupancies. ARIES conducted a survey of PHAs to assess their receptiveness to this concept and the applicability of the concept to PHA units. The results of the survey, to which more than 100 PHAs responded, support the proposed approach. The project consisted of a field evaluation in which energy audits were performed on a sample of PHA units at two housing authorities. Energy efficiency turnover protocols were developed for typical units, the protocol was implemented by PHA staff, and the effectiveness of the protocol was quantified through field testing and modeling. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing, and measures that improve equipment efficiency. In the 10 housing units in which ARIES documented implementation, reductions in average air leakage of 16%-20% and duct leakage of 38% were obtained. Total source energy consumption savings was estimated at 6%-10% based on Building Energy Optimization modeling with a simple payback of 1.7-2.2 years. Implementation challenges were encountered, mainly related to required operational changes and budgetary constraints. Lack of complete training and inadequate quality control can prevent PHAs from effectively retrofitting units to their full potential. Nevertheless, despite these hurdles, simple improvements, such as caulking and sealing penetrations, windows, and doors; sealing duct boots; and adding pipe insulation into a standardized turnover protocol can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of units per year nationally. Islip Housing Authority - Single Story Typical home - Raleigh, NC Raleigh Housing Authority - 2 story typical home in Raleigh housing authority - Terrace Park

air filtration↗

Building a 40% Energy Saving House in the Mixed-Humid Climate

This report describes a home that uses 40% less energy than the energy-efficient Building America standard - a giant step in the pursuit of affordable near-zero-energy housing through the evolution of five near-zero-energy research houses. This four-bedroom, two-bath, 1232-ft2 house has a Home Energy Rating System (HERS) index of 35 (a HERS rating of 0 is a zero-energy house, a conventional new house would have a HERS rating of 100), which qualifies it for federal energy efficiency and solar incentives. The house is leading to the planned construction of a similar home in Greensburg, Kansas, and 21 staff houses in the Walden Reserve, a 7000-unit "deep green" community in Cookville, Tennessee. Discussions are underway for construction of similar houses in Charleston, South Carolina, Seattle, Washington, Knoxville and Oak Ridge, Tennessee, and upstate New York. This house should lead to a 40% and 50% Gate-3, Mixed-Humid-Climate Joule for the DOE Building America Program. The house is constructed with structurally-insulated-panel walls and roof, raised metal-seam roof with infrared reflective coating, airtight envelope (1.65 air changes per hour at 50 Pascal), supply mechanical ventilation, ducts inside the conditioned space, extensive moisture control package, foundation geothermal space heating and cooling system, ZEHcor wall, solar water heater, and a 2.2 kWp grid-connected photovoltaic (PV) system. The detailed specifications for the envelope and the equipment used in ZEH5 compared to all the houses in this series are shown in Tables 1 and 2. Based on a validated computer simulation of ZEH5 with typical occupancy patterns and energy services for four occupants, energy for this all-electric house is predicted to cost only $0.66/day ($0.86/day counting the hookup charges). By contrast, the benchmark house would require $3.56/day, including hookup charges (these costs are based on a 2006 residential rates of $0.07/kWh and solar buyback at $0.15/kWh). The solar fraction for this home located in Lenoir City, Tennessee, is predicted to be as high as 41%(accounting for both solar PV and the solar water heater). This all-electric home is predicted to use 25 kWh/day based on the one year of measured data used to calibrate a whole-building simulation model. Based on two years of measured data, the roof-mounted 2.2 kWp PV system is predicted to generate 7.5 kWh/day. The 2005 cost to commercially construct ZEH5, including builder profit and overhead, is estimated at about $150,000. This cost - for ZEH5's panelized construction, premanufactured utility wall (ZEHcor), foundation geothermal system, and the addition of the walkout lower level, and considering the falling cost for PV - suggests that the construction cost per ft2 for a ZEH5 two-story will be even more cost-competitive. The 2005 construction cost estimate for a finished-out ZEH5 with 2632 ft2 is $222,000 or $85/ft2. The intention of this report is to help builders and homeowners make the decision to build zero-energy-ready homes. Detailed drawings, specifications, and lessons learned in the construction and analysis of data from about 100 sensors monitoring thermal performance for a one-year period are presented. This information should be specifically useful to those considering structural insulated panel walls and roof, foundation geothermal space heating and cooling, solar water heater and roof-mounted, photovoltaic, grid-tied systems.

14 SOLAR ENERGY↗

Analysis of Exposure during Transportation of Waste to the Nevada National Security Site (NNSS) - 20445

Safety is a priority for the U.S. Department of Energy (DOE) Environmental Management (EM) Nevada Program. This commitment to safety is integrated into requirements and work procedures at DOE sites across the U.S. that generate low-level radioactive waste, mixed low-level radioactive waste, and classified waste that is transported to the Nevada National Security Site (NNSS) for permanent disposal. Generators of this waste are responsible for ensuring it is packaged and transported in a safe and compliant manner. These generators and their contracted commercial carriers must comply with U.S. Department of Transportation (DOT) regulations; the Nevada National Security Site Waste Acceptance Criteria (NNSSWAC); and other applicable federal, state, and local regulations and requirements. This includes packaging and shipping the waste to meet DOT regulatory radiation dose limits to ensure public safety during transportation. NNSS waste generators have a solid safety record for complying with these stringent regulations as demonstrated by the fact that no shipments exceeding DOT dose rate limits were received at the NNSS Area 5 Radioactive Waste Management Complex (RWMC) during FY 2014 through FY 2018. A 2005 study conducted by the Desert Research Institute validated shipments to the NNSS comply with DOT radiation dose limits. In response to recent Nevada stakeholder requests for an updated study, an analysis was conducted to verify and provide evidence that the public continues to be safe from exposure to radioactive waste shipment to the NNSS. Radiation exposure from radioactive waste shipments in transit to the NNSS was evaluated. Three studies were performed: 1. Confirm compliance of waste shipments to the DOT radiation limits using dose rate surveys taken at the generator site and at the disposal site. 2. Estimate the dose to the public from waste shipments using the dosimetry results for disposal site personnel by comparing time of exposure for various individuals/scenarios. 3. Estimate the truck driver dose using the receipt dose rate surveys and time of exposure, and from dosimetry results. Study 1 confirmed compliance with the DOT dose rate limits for a sample of waste shipments (123 of 1,038) received during fiscal year (FY) 2017. Study 2 showed that the average annual radiation equivalent dose for disposal site personnel during FY 2017 was approximately 6.7% [0.415 mSv (41.5 millirem)] of the annual average dose that a person living in the U.S. receives from all sources [6.2 mSv (620 mrem)]. Maximum dose to a member of the public, a person resting/sleeping in an adjacent truck at a rest area to a waste shipment, was 0.0166 mSv (1.66 mrem), which is less than the dose received from a person taking a round trip from the east coast to the west coast of the continental U.S. on an airplane [0.07 mSv (7 mrem) per round trip]. Study 3 showed that the truck driver who made the most shipments of radioactive waste to the NNSS, who drove the most hours (estimated time of exposure 2,520 hours), during FY 2017 had a total dose of 0.15 mSv (15 mrem), which was obtained from their personal dosimeter. The annual dose recorded for disposal site personnel, the dose estimates for the public, and the truck driver dose were all a small percentage of the average radiation dose a person receives from all sources (e.g., background and medical radiation). At these levels, risk should only be described qualitatively. Radiation exposure from radioactive waste shipments to the NNSS were shown to be compliant with the DOT dose rate limits, safe, and very low (i.e., within background levels). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving Ventilation and Saving Energy: Final Report on Indoor Environmental Quality and Energy Monitoring in Sixteen Relocatable Classrooms

An improved HVAC system for portable classrooms was specified to address key problems in existing units. These included low energy efficiency, poor control of and provision for adequate ventilation, and excessive acoustic noise. Working with industry, a prototype improved heat pump air conditioner was developed to meet the specification. A one-year measurement-intensive field-test of ten of these IHPAC systems was conducted in occupied classrooms in two distinct California climates. These measurements are compared to those made in parallel in side by side portable classrooms equipped with standard 10 SEER heat pump air conditioner equipment. The IHPAC units were found to work as designed, providing predicted annual energy efficiency improvements of about 36 percent to 42 percent across California's climate zones, relative to 10 SEER units. Classroom ventilation was vastly improved as evidenced by far lower indoor minus outdoor CO2 concentrations. TheIHPAC units were found to provide ventilation that meets both California State energy and occupational codes and the ASHRAE minimum ventilation requirements; the classrooms equipped with the 10 SEER equipment universally did not meet these targets. The IHPAC system provided a major improvement in indoor acoustic conditions. HVAC system generated background noise was reduced in fan-only and fan and compressor modes, reducing the nose levels to better than the design objective of 45 dB(A), and acceptable for additional design points by the Collaborative on High Performance Schools. The IHPAC provided superior ventilation, with indoor minus outdoor CO2 concentrations that showed that the Title 24 minimum ventilation requirement of 15 CFM per occupant was nearly always being met. The opposite was found in the classrooms utilizing the 10 SEER system, where the indoor minus outdoor CO2 concentrations frequently exceeded levels that reflect inadequate ventilation. Improved ventilation conditions in the IHPAC lead to effective removal of volatile organic compounds and aldehydes, on average lowering the concentrations by 57 percent relative to the levels in the 10 SEER classrooms. The average IHPAC to 10 SEER formaldehyde ratio was about 67 percent, indicating only a 33 percent reduction of this compound in indoor air. The IHPAC thermal control system provided less variability in occupied classroom temperature than the 10 SEER thermostats. The average room temperatures in all seasons tended to be slightly lower in the IHPAC classrooms, often below the lower limit of the ASHRAE 55 thermal comfort band. State-wide and national energy modeling provided conservative estimates of potential energy savings by use of the IHPAC system that would provide payback a the range of time far lower than the lifetime of the equipment. Assuming electricity costs of $0.15/kWh, the perclassroom range of savings is from about $85 to $195 per year in California, and about $89 to $250 per year in the U.S., depending upon the city. These modelsdid not include the non-energy benefits to the classrooms including better air quality and acoustic conditions that could lead to improved health and learning in school. Market connection efforts that were part of the study give all indication that this has been a very successful project. The successes include the specification of the IHPAC equipment in the CHPS portable classroom standards, the release of a commercial product based on the standards that is now being installed in schools around the U.S., and the fact that a public utility company is currently considering the addition of the technology to its customer incentive program. These successes indicate that the IHPAC may reach its potential to improve ventilation and save energy in classrooms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comments on shielding for dual energy accelerators

Determination of shielding requirements for medical linear accelerators has been greatly facilitated by the publication of the National Council on Radiation Protection and Measurements (NCRP) latest guidelines on this subject in NCRP Report No. 151. In the present report the authors review their own recent experience with patient treatments on conventional dual energy linear accelerators to examine the various input parameters needed to follow the NCRP guidelines. Some discussion is included of workloads, occupancy, use factors, and field size, with the effects of intensity modulated radiotherapy (IMRT) treatments included. Studies of collimator settings showed average values of 13.1x16.2 cm{sup 2} for 6 MV and 14.1x16.8 cm{sup 2} for 18 MV conventional ports, and corresponding average unblocked areas of 228 and 254 cm{sup 2}, respectively. With an average of 77% of the field area unblocked, this gives a mean irradiated area of 196 cm{sup 2} for the 18 MV beam, which dominates shielding considerations for most dual energy machines. Assuming conservatively small room dimensions, a gantry bin angle of 18 deg. was found to represent a reasonable unit for tabulation of use factors. For conventional 18 MV treatments it was found that the usual treatment angles of 0, 90, 180, and 270 deg. were still favored, and use factors of 0.25 represent reasonable estimates for these beams. As expected, the IMRT fields (all at 6 MV) showed a high degree of gantry angle randomization, with no bin having a use factor in excess of 0.10. It is concluded that unless a significant number of patients are treated with high energy IMRT, the traditional use factors of 0.25 are appropriate for the dominant high energy beam.

61 RADIATION PROTECTION AND DOSIMETRY↗

THE INTEGRATED STELLAR CONTENT OF DARK MATTER HALOS

Measurements of the total amount of stars locked up in galaxies as a function of host halo mass contain key clues about the efficiency of processes that regulate star formation. We derive the total stellar mass fraction f{sub *} (excluding stars in the intracluster light) as a function of halo mass M{sub 500c} from z = 0.2 to z = 1 using two complementary methods. First, we derive f{sub *} using a statistical Halo Occupation Distribution model jointly constrained by data from lensing, clustering, and the stellar mass function. This method enables us to probe f{sub *} over a much wider halo mass range than with group or cluster catalogs. Second, we derive f{sub *} at group scales using a COSMOS X-ray group catalog and show that the two methods agree to within 30%. We quantify the systematic uncertainty on f{sub *} using abundance matching methods and show that the statistical uncertainty on f{sub *} ({approx}10%) is dwarfed by systematic uncertainties associated with stellar mass measurements ({approx}45% excluding initial mass function, IMF, uncertainties). Assuming a Chabrier IMF, we find 0.012 {<=} f{sub *} {<=} 0.025 at M{sub 500c} = 10{sup 13} M{sub Sun} and 0.0057 {<=} f{sub *} {<=} 0.015 at M{sub 500c} = 10{sup 14} M{sub Sun }. These values are significantly lower than previously published estimates. We investigate the cause of this difference and find that previous work has overestimated f{sub *} owing to a combination of inaccurate stellar mass estimators and/or because they have assumed that all galaxies in groups are early-type galaxies with a constant mass-to-light ratio. Contrary to previous claims, our results suggest that the mean value of f{sub *} is always significantly lower than f{sub gas} for halos above 10{sup 13} M{sub Sun }. Combining our results with recently published gas mass fractions, we find a shortfall in f{sub *} + f{sub gas} at R{sub 500c} compared to the cosmic mean. This shortfall varies with halo mass and becomes larger toward lower halo masses.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-365: Estimation of Neutron Ambient Dose Equivalents for Radioprotection Exposed Workers in Radiotherapy Facilities Based On Characterization Patient Risk Estimation

Purpose: Previous measurements with Bonner spheres{sup 1} showed that normalized neutron spectra are equal for the majority of the existing linacs{sup 2}. This information, in addition to thermal neutron fluences obtained in the characterization procedure{sup 3}3, would allow to estimate neutron doses accidentally received by exposed workers, without the need of an extra experimental measurement. Methods: Monte Carlo (MC) simulations demonstrated that the thermal neutron fluence distribution inside the bunker is quite uniform, as a consequence of multiple scatter in the walls{sup 4}. Although inverse square law is approximately valid for the fast component, a more precise calculation could be obtained with a generic fast fluence distribution map around the linac, from MC simulations{sup 4}. Thus, measurements of thermal neutron fluences performed during the characterization procedure{sup 3}, together with a generic unitary spectra{sup 2}, would allow to estimate the total neutron fluences and H*(10) at any point{sup 5}. As an example, we compared estimations with Bonner sphere measurements{sup 1}, for two points in five facilities: 3 Siemens (15–23 MV), Elekta (15 MV) and Varian (15 MV). Results: Thermal neutron fluences obtained from characterization, are within (0.2–1.6×10{sup 6}) cm−{sup 2}•Gy{sup −1} for the five studied facilities. This implies ambient equivalent doses ranging from (0.27–2.01) mSv/Gy 50 cm far from the isocenter and (0.03–0.26) mSv/Gy at detector location with an average deviation of ±12.1% respect to Bonner measurements. Conclusion: The good results obtained demonstrate that neutron fluence and H*(10) can be estimated based on: (a) characterization procedure established for patient risk estimation in each facility, (b) generic unitary neutron spectrum and (c) generic MC map distribution of the fast component. [1] Radiat. Meas (2010) 45: 1391 – 1397; [2] Phys. Med. Biol (2012) 5 7:6167–6191; [3] Med. Phys (2015) 42:276 - 281. [4] IFMBE (2012) 39: 1245–1248. [5] ICRU Report 57 (1998)

60 APPLIED LIFE SCIENCES↗

Disaggregating measurement uncertainty from population variability and Bayesian treatment of uncensored results

In making low-level radioactivity measurements of populations, it is commonly observed that a substantial portion of net results are negative. Furthermore, the observed variance of the measurement results arises from a combination of measurement uncertainty and population variability. This paper presents a method for disaggregating measurement uncertainty from population variability to produce a probability density function (PDF) of possibly true results. To do this, simple, justifiable, and reasonable assumptions are made about the relationship of the measurements to the measurands (the 'true values'). The measurements are assumed to be unbiased, that is, that their average value is the average of the measurands. Using traditional estimates of each measurement's uncertainty to disaggregate population variability from measurement uncertainty, a PDF of measurands for the population is produced. Then, using Bayes's theorem, the same assumptions, and all the data from the population of individuals, a prior PDF is computed for each individual's measurand. These PDFs are non-negative, and their average is equal to the average of the measurement results for the population. The uncertainty in these Bayesian posterior PDFs is all Berkson with no remaining classical component. The methods are applied to baseline bioassay data from the Hanford site. The data include 90Sr urinalysis measurements on 128 people, 137Cs in vivo measurements on 5,337 people, and 239Pu urinalysis measurements on 3,270 people. The method produces excellent results for the 90Sr and 137Cs measurements, since there are nonzero concentrations of these global fallout radionuclides in people who have not been occupationally exposed. The method does not work for the 239Pu measurements in non-occupationally exposed people because the population average is essentially zero.

61 RADIATION PROTECTION AND DOSIMETRY↗

Downlight Demonstration Program: Hilton Columbus Downtown

The U.S. Department of Energy (DOE) estimates that there were about 700 million downlight luminaires installed in residential and commercial buildings in the U.S. as of 2012, with light-emitting diode (LED) luminaires representing less than 1% of this installed base. Downlight luminaires using conventional incandescent, halogen, and compact fluorescent lamps have lower efficacies and shorter expected lifetimes than comparable LED systems, but the lower initial cost of the conventional technology and the uncertainties associated with the newer LED technology have restricted widespread adoption of LED downlight luminaires. About 278 tBtu of energy could be saved annually if LED luminaires were to saturate the downlight market, equating to an annual energy cost savings of $2.6 billion. This report summarizes an evaluation of LED recessed downlight luminaires in the guest rooms at the Hilton Columbus Downtown hotel in Columbus, OH. The facility opened in October of 2012, and the U.S. Department of Energy (DOE) conducted a post-occupancy assessment of the facility in January–March of 2014. Each of the 484 guest rooms uses seven 15 W LED downlights: four downlights in the entry and bedroom and three downlights in the bathroom. The 48 suites use the seven 15 W LED downlights and additional fixtures depending on the space requirements, so that in total the facility has more than 3,700 LED downlights. The downlights are controlled through wall-mounted switches and dimmers. A ceiling-mounted vacancy sensor ensures that the bathroom luminaires are turned off when the room is not occupied.

Davis, Robert G.↗

A bespoke health risk assessment methodology for the radiation protection of astronauts

An alternative approach that is particularly suitable for the radiation health risk assessment (HRA) of astronauts is presented. The quantity, Radiation Attributed Decrease of Survival (RADS), representing the cumulative decrease in the unknown survival curve at a certain attained age, due to the radiation exposure at an earlier age, forms the basis for this alternative approach. Results are provided for all solid cancer plus leukemia incidence RADS from estimated doses from theoretical radiation exposures accumulated during long-term missions to the Moon or Mars. For example, it is shown that a 1000-day Mars exploration mission with a hypothetical mission effective dose of 1.07 Sv at typical astronaut ages around 40 years old, will result in the probability of surviving free of all types of solid cancer and leukemia until retirement age (65 years) being reduced by 4.2% (95% CI 3.2; 5.3) for males and 5.8% (95% CI 4.8; 7.0) for females. RADS dose–responses are given, for the outcomes for incidence of all solid cancer, leukemia, lung and female breast cancer. Results showing how RADS varies with age at exposure, attained age and other factors are also presented. The advantages of this alternative approach, over currently applied methodologies for the long-term radiation protection of astronauts after mission exposures, are presented with example calculations applicable to European astronaut occupational HRA. Some tentative suggestions for new types of occupational risk limits for space missions are given while acknowledging that the setting of astronaut radiation-related risk limits will ultimately be decided by the Space Agencies. Suggestions are provided for further work which builds on and extends this new HRA approach, e.g., by eventually including non-cancer effects and detailed space dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗